alarm dictionary

550
Title page Alcatel-Lucent Base St at io n | B12 BTS Alarm Dictionary 9YZ-03803-1330-PCZZA Is sue 4 | September 2012 Alcatel-Lu cent Proprieta ry Use pursuant to applicable agreements

Upload: sami

Post on 03-Jun-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 1/549

Title page

Alcatel-LucentBase Station | B12

BTS Alarm Dictionary

9YZ-03803-1330-PCZZAIssue 4 | September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Page 2: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 2/549

Page 3: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 3/549

Contents

About this document

Purpose  ............................................................................................................................................................................................ xlixli

Reason for reissue   ....................................................................................................................................................................... xlixli

Intended audience   ...................................................................................................................................................................... xliixlii

Supported systems   ..................................................................................................................................................................... xliixlii

How to use this document   ....................................................................................................................................................... xliixlii

How to comment  ........................................................................................................................................................................

 xliixlii

Part I: Introduction to the BTS alarm dictionary

1   Relationships Between SBLs and MOs

SBL State to MO State translation

Translation table  ........................................................................................................................................................................ 1-11-1

State change commands translation

Translation table  ........................................................................................................................................................................

1-21-2

Mapping of MO Perceived Severity to BSS Alarm category

Mapping table ............................................................................................................................................................................. 1-31-3

2   9153 OMC-R Alarm Surveillance information

Introduction

Alarm Surveillance ................................................................................................................................................................... 2-12-1

Object identification

Description  .................................................................................................................................................................................. 2-22-2

Alarm type

Overview  ...................................................................................................................................................................................... 2-32-3

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

iii

Page 4: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 4/549

3   LMT alarm messages

Overview

Information .................................................................................................................................................................................. 3-13-1

BTS LMT alarm message parameters

Introduction  ................................................................................................................................................................................. 3-23-2

4   BTS alarm information

Overview  ...................................................................................................................................................................................... 4-14-1

Alarm Definition

Overview  ...................................................................................................................................................................................... 4-24-2

specific Problems  ......................................................................................................................................................................

4-24-2

eventType  ..................................................................................................................................................................................... 4-24-2

 probable Cause ........................................................................................................................................................................... 4-34-3

 perceived Severity   .................................................................................................................................................................... 4-34-3

Alarm Description

Banner   ........................................................................................................................................................................................... 4-44-4

Alarm Description   .................................................................................................................................................................... 4-44-4

Impact on System   ..................................................................................................................................................................... 4-44-4

Corrective actions   ..................................................................................................................................................................... 4-54-5

Additional Information

Description  .................................................................................................................................................................................. 4-74-7

Part II: Class 1: CLK alarms

5   [1,6] MCL-FATAL-AL

Definition  ..................................................................................................................................................................................... 5-15-1

Impacts .......................................................................................................................................................................................... 5-15-1

BTS 9100 corrective actions   ................................................................................................................................................. 5-25-2

BTS 9110/9110-E corrective actions   ................................................................................................................................. 5-35-3

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

iv   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 5: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 5/549

6   [1,12] CLOCK-FAULT

Definition  ..................................................................................................................................................................................... 6-16-1

Impacts .......................................................................................................................................................................................... 6-16-1

BTS 9100 corrective actions  .................................................................................................................................................

6-26-2

BTS 9110/9110-E corrective actions   ................................................................................................................................. 6-36-3

7   [1,31] MCL-XCLK 

Definition  ..................................................................................................................................................................................... 7-17-1

Impacts .......................................................................................................................................................................................... 7-17-1

BTS 9100 corrective actions   ................................................................................................................................................. 7-27-2

BTS 9110/9110-E corrective actions   ................................................................................................................................. 7-37-3

8   [1,234] IOM-DISCONNECTION

Definition  ..................................................................................................................................................................................... 8-18-1

Impacts .......................................................................................................................................................................................... 8-18-1

corrective actions   ...................................................................................................................................................................... 8-28-2

9   [1,237] HW-DEGRADED

Definition  ..................................................................................................................................................................................... 9-19-1

Impacts .......................................................................................................................................................................................... 9-29-2

9100 BTS, Alarm Number 1 corrective actions ............................................................................................................. 9-39-3

9100 BTS, Alarm Number 2, 3, 4 , 5 and 6 corrective actions   ................................................................................ 9-49-4

9100 BTS, Alarm Number 7 corrective actions ............................................................................................................. 9-59-5

9110 Micro BTS/9110-E Micro BTS, Alarm Number 1 corrective actions  ........................................................ 9-69-6

9110 Micro BTS/9110-E Micro BTS, Alarm Number 2 corrective actions  ........................................................ 9-79-7

10   [1,248] RESTART

Definition   .................................................................................................................................................................................. 10-110-1

Impacts   ....................................................................................................................................................................................... 10-110-1

BTS 9100 corrective actions   .............................................................................................................................................. 10-210-2

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

v

Page 6: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 6/549

BTS 9110/9110-E corrective actions ............................................................................................................................... 10-310-3

Part III: Class 2: OMU Alarms

11   [2,1] LOSS OF TWIN CONFIGURATION

Description  ................................................................................................................................................................................

11-111-1

Impacts   ....................................................................................................................................................................................... 11-111-1

corrective actions  .................................................................................................................................................................... 11-211-2

12   [2,247] RESET

Description  ................................................................................................................................................................................ 12-112-1

Impacts   ....................................................................................................................................................................................... 12-212-2

Alarm Number 3 corrective actions.................................................................................................................................

 12-312-3

Alarm Number 4 corrective actions .................................................................................................................................  12-412-4

Alarm Number 5 corrective actions .................................................................................................................................  12-512-5

Alarm Number 6 corrective actions .................................................................................................................................  12-512-5

Alarm Number 7 corrective actions .................................................................................................................................  12-612-6

Alarm Number 8 corrective actions .................................................................................................................................  12-712-7

13   [2,248] RESTART

Description  ................................................................................................................................................................................ 13-113-1

Impacts   ....................................................................................................................................................................................... 13-113-1

corrective actions  .................................................................................................................................................................... 13-213-2

Part IV: Class 3: SW-AN Alarms

14   [3,11] SW-PROBLEM

[3,11] SW-PROBLEM (CLLK)

Definition   .................................................................................................................................................................................. 14-114-1

Impacts   ....................................................................................................................................................................................... 14-214-2

BTS 9100 corrective actions   .............................................................................................................................................. 14-314-3

BTS 9110/9110-E corrective actions ............................................................................................................................... 14-414-4

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

vi   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 7: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 7/549

[3,11] SW-PROBLEM (TRE)

Definition   .................................................................................................................................................................................. 14-514-5

Impacts   ....................................................................................................................................................................................... 14-614-6

BTS 9100 corrective actions  ..............................................................................................................................................

 14-614-6

BTS 9110/9110-E corrective actions ............................................................................................................................... 14-814-8

Distributed BTS corrective actions   .................................................................................................................................. 14-914-9

[3,11] SW-PROBLEM (RA)

Definition  ................................................................................................................................................................................ 14-1114-11

Impacts  ..................................................................................................................................................................................... 14-1114-11

Corrective actions   ................................................................................................................................................................ 14-1214-12

15   [3,13] TELECOM-CONFIG-FAIL

Definition   .................................................................................................................................................................................. 15-115-1

Impacts   ....................................................................................................................................................................................... 15-215-2

Corrective actions ................................................................................................................................................................... 15-215-2

16   [3,14] WRONG-CONFIGURATION

[3,14] WRONG-CONFIGURATION (TRE)

Definition   .................................................................................................................................................................................. 16-116-1

Impacts   ....................................................................................................................................................................................... 16-216-2

Alarm Number 1, 2, 3, 6, corrective actions   ................................................................................................................ 16-316-3

Alarm Number 4, corrective actions   ............................................................................................................................... 16-416-4

Alarm Number 5, corrective actions   ............................................................................................................................... 16-516-5

Alarm Number 7, 9, corrective actions   .......................................................................................................................... 16-616-6

Alarm Number 8, corrective actions  ...............................................................................................................................

16-716-7

Alarm Number 11, corrective actions   ............................................................................................................................. 16-816-8

Alarm Number 16, corrective actions  ............................................................................................................................. 16-916-9

Alarm Number 17, corrective actions  ............................................................................................................................. 16-916-9

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

vii

Page 8: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 8/549

Page 9: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 9/549

BTS 9100 corrective actions   .............................................................................................................................................. 17-917-9

BTS 9110/9110-E corrective actions   ............................................................................................................................ 17-1017-10

Part V: Class 5: ENVIR Alarms

18   [5,1] FAN-ALARM

Definition   .................................................................................................................................................................................. 18-118-1

Impacts   ....................................................................................................................................................................................... 18-118-1

Corrective actions ................................................................................................................................................................... 18-218-2

19   [5,11] POWER-SUPPLY-U

Definition   .................................................................................................................................................................................. 19-119-1

Impacts  .......................................................................................................................................................................................

19-119-1

Corrective actions ................................................................................................................................................................... 19-219-2

20   [5,12] POWER-SUPPLY-NU

Definition   .................................................................................................................................................................................. 20-120-1

Impacts   ....................................................................................................................................................................................... 20-120-1

Corrective actions ................................................................................................................................................................... 20-220-2

21   [5,13] CONTROL-UNIT-AL

Definition   .................................................................................................................................................................................. 21-121-1

Impacts   ....................................................................................................................................................................................... 21-121-1

Corrective actions ................................................................................................................................................................... 21-221-2

22   [5,20] MAINS-AL

Definition   .................................................................................................................................................................................. 22-122-1

Impacts   ....................................................................................................................................................................................... 22-122-1

Corrective actions ................................................................................................................................................................... 22-222-2

23   [5,23] POWER-SHUTDOWN

Definition   .................................................................................................................................................................................. 23-123-1

Impacts   ....................................................................................................................................................................................... 23-123-1

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

ix

Page 10: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 10/549

Alarm Number 1 corrective actions .................................................................................................................................  23-223-2

Alarm Number 2 corrective actions .................................................................................................................................  23-323-3

24   [5,24] SUBRACK-POWER 

Definition  ..................................................................................................................................................................................

24-124-1

Impacts   ....................................................................................................................................................................................... 24-124-1

Corrective actions ................................................................................................................................................................... 24-224-2

25   [5,31] TEMPERATURE-WARNING

[5,31] TEMPERATURE-WARNING (BTS)

Definition   .................................................................................................................................................................................. 25-125-1

Impacts  .......................................................................................................................................................................................

25-125-1

Corrective actions ................................................................................................................................................................... 25-225-2

[5,31] TEMPERATURE-WARNING (TRE)

Definition   .................................................................................................................................................................................. 25-425-4

Impacts   ....................................................................................................................................................................................... 25-425-4

Corrective actions ................................................................................................................................................................... 25-425-4

26   [5,32] FATAL TEMPERATURE

Definition   .................................................................................................................................................................................. 26-126-1

Impacts   ....................................................................................................................................................................................... 26-126-1

Corrective actions ................................................................................................................................................................... 26-226-2

27   [5, 40] CPRI_LINK_PROBLEM

Definition   .................................................................................................................................................................................. 27-127-1

Corrective actions ................................................................................................................................................................... 27-127-1

28   [5,237] HW-DEGRADED

[5,237] HW-DEGRADED (BTS)

Definition   .................................................................................................................................................................................. 28-128-1

Impacts   ....................................................................................................................................................................................... 28-128-1

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

x   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 11: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 11/549

Corrective actions ................................................................................................................................................................... 28-228-2

[5,237] HW-DEGRADED (EACB)

Definition   .................................................................................................................................................................................. 28-328-3

Impacts  .......................................................................................................................................................................................

28-328-3

Alarm Number 10 BTS 9100 corrective actions ......................................................................................................... 28-328-3

Alarm Number 10 BTS 9110/9110-E corrective actions   ......................................................................................... 28-528-5

[5,237] HW-DEGRADED (RA)

Definition   .................................................................................................................................................................................. 28-628-6

Impacts   ....................................................................................................................................................................................... 28-628-6

Alarm Number 11..17 corrective actions  ....................................................................................................................... 28-728-7

[5,237] HW-DEGRADED (CCF)

Definition   .................................................................................................................................................................................. 28-828-8

Impacts   ....................................................................................................................................................................................... 28-828-8

Corrective actions ................................................................................................................................................................... 28-928-9

29   [5,239] HW-FAILURE

[5,239] HW-FAILURE (EACB)

Definition   .................................................................................................................................................................................. 29-129-1

Impacts   ....................................................................................................................................................................................... 29-129-1

Alarm Number 2 corrective actions .................................................................................................................................  29-229-2

Alarm Number 3 corrective actions .................................................................................................................................  29-329-3

[5,239] HW-FAILURE (CCF)

Definition   .................................................................................................................................................................................. 29-429-4

Impacts   ....................................................................................................................................................................................... 29-429-4

Corrective actions ................................................................................................................................................................... 29-429-4

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xi

Page 12: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 12/549

Part VI: Class 8: Global BTS alarms

30   [8,3] RESYNCH

Definition   .................................................................................................................................................................................. 30-130-1

Impacts  .......................................................................................................................................................................................

30-130-1

Corrective actions ................................................................................................................................................................... 30-230-2

31   [8,4] IGNORE PLUGGED BUT NOT USABLE EQUIPMENT

Definition   .................................................................................................................................................................................. 31-131-1

Impacts   ....................................................................................................................................................................................... 31-231-2

Corrective actions ................................................................................................................................................................... 31-231-2

32   [8,5] TOO MANY PLUGGED MODULES

Definition   .................................................................................................................................................................................. 32-132-1

Impacts   ....................................................................................................................................................................................... 32-132-1

Corrective actions ................................................................................................................................................................... 32-232-2

33   [8,8] HW-RESYNCH

Definition   .................................................................................................................................................................................. 33-133-1

Impacts   ....................................................................................................................................................................................... 33-133-1

Corrective actions ................................................................................................................................................................... 33-233-2

34   [8,30] BCB-LINK 

[8,30] BCB-LINK (BTS)

Definition   .................................................................................................................................................................................. 34-134-1

Impacts   ....................................................................................................................................................................................... 34-134-1

BTS 9100 corrective actions   .............................................................................................................................................. 34-234-2

BTS 9110/9110-E corrective actions ............................................................................................................................... 34-434-4

[8,30] BCB-LINK (CCF)

Definition   .................................................................................................................................................................................. 34-634-6

BTS 9100 corrective actions   .............................................................................................................................................. 34-734-7

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xii   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 13: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 13/549

35   [8,31] IOM-LINK 

Definition   .................................................................................................................................................................................. 35-135-1

Impacts   ....................................................................................................................................................................................... 35-135-1

BTS 9100 corrective actions  ..............................................................................................................................................

 35-235-2

BTS 9110/9110-E corrective actions ............................................................................................................................... 35-335-3

36   [8,32] MODULE-INSERTED

[8,32] MODULE-INSERTED (BTS)

Definition   .................................................................................................................................................................................. 36-136-1

Impacts   ....................................................................................................................................................................................... 36-136-1

BTS 9100 corrective actions   .............................................................................................................................................. 36-236-2

BTS 9110/9110-E corrective actions ............................................................................................................................... 36-436-4

[8,32] MODULE-INSERTED (RA)

Definition   .................................................................................................................................................................................. 36-636-6

Impacts   ....................................................................................................................................................................................... 36-636-6

BTS 9100 corrective actions   .............................................................................................................................................. 36-636-6

BTS 9110/9110-E corrective actions ............................................................................................................................... 36-836-8

37   [8,40] REDUNDANT-CONNECTION-LOST

Definition   .................................................................................................................................................................................. 37-137-1

Corrective actions ................................................................................................................................................................... 37-237-2

38   [8,247] RESET (BTS)

Definition   .................................................................................................................................................................................. 38-138-1

Impacts   ....................................................................................................................................................................................... 38-138-1

Corrective actions ................................................................................................................................................................... 38-238-2

39   [8,248] RESTART

Definition   .................................................................................................................................................................................. 39-139-1

Impacts   ....................................................................................................................................................................................... 39-139-1

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xiii

Page 14: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 14/549

Corrective actions ................................................................................................................................................................... 39-239-2

Part VII: Class 9: BTS-EXTERNAL alarms

40   [9,1...56] EXT-ALARM

Definition  ..................................................................................................................................................................................

40-140-1

Impacts   ....................................................................................................................................................................................... 40-240-2

Corrective actions ................................................................................................................................................................... 40-340-3

41   [9,1] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 41-141-1

Impacts   ....................................................................................................................................................................................... 41-141-1

Corrective actions...................................................................................................................................................................

41-241-2

42   [9,2] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 42-142-1

Impacts   ....................................................................................................................................................................................... 42-142-1

Corrective actions ................................................................................................................................................................... 42-242-2

43   [9,3] EXT-ALARM (Default)

Definition  ..................................................................................................................................................................................

43-143-1

Impacts   ....................................................................................................................................................................................... 43-243-2

Corrective actions ................................................................................................................................................................... 43-343-3

BTS 9110/9110-E corrective actions ............................................................................................................................... 43-443-4

44   [9,4] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 44-144-1

Impacts   ....................................................................................................................................................................................... 44-144-1

Corrective actions ................................................................................................................................................................... 44-244-2

45   [9,5] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 45-145-1

Impacts   ....................................................................................................................................................................................... 45-145-1

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xiv   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 15: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 15/549

Corrective actions ................................................................................................................................................................... 45-245-2

46   [9,6] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 46-146-1

Impacts  .......................................................................................................................................................................................

46-146-1

Corrective actions ................................................................................................................................................................... 46-246-2

47   [9,7] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 47-147-1

Impacts   ....................................................................................................................................................................................... 47-147-1

Corrective actions ................................................................................................................................................................... 47-247-2

48   [9,8] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 48-148-1

Impacts   ....................................................................................................................................................................................... 48-148-1

Corrective actions ................................................................................................................................................................... 48-248-2

49   [9,9] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 49-149-1

Impacts   ....................................................................................................................................................................................... 49-149-1

Corrective actions ................................................................................................................................................................... 49-249-2

50   [9,10] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 50-150-1

Impacts   ....................................................................................................................................................................................... 50-150-1

Corrective actions ................................................................................................................................................................... 50-250-2

51   [9,11] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 51-151-1

Impacts   ....................................................................................................................................................................................... 51-151-1

Corrective actions ................................................................................................................................................................... 51-251-2

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xv

Page 16: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 16/549

52   [9,12] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 52-152-1

Impacts   ....................................................................................................................................................................................... 52-152-1

Corrective actions...................................................................................................................................................................

52-252-2

53   [9,13] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 53-153-1

Impacts   ....................................................................................................................................................................................... 53-153-1

BTS 9100 corrective actions   .............................................................................................................................................. 53-253-2

54   [9,14] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 54-154-1

Impacts   ....................................................................................................................................................................................... 54-154-1

BTS 9100 corrective actions   .............................................................................................................................................. 54-254-2

55   [9,15] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 55-155-1

Impacts   ....................................................................................................................................................................................... 55-155-1

BTS 9100 corrective actions   .............................................................................................................................................. 55-255-2

56   [9,16] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 56-156-1

Impacts   ....................................................................................................................................................................................... 56-156-1

corrective actions  .................................................................................................................................................................... 56-256-2

57   [9,17] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 57-157-1

Impacts   ....................................................................................................................................................................................... 57-157-1

Corrective actions ................................................................................................................................................................... 57-257-2

58   [9,18] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 58-158-1

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xvi   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 17: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 17/549

Impacts   ....................................................................................................................................................................................... 58-158-1

Corrective actions ................................................................................................................................................................... 58-258-2

59   [9,19] EXT-ALARM (Default)

Definition  ..................................................................................................................................................................................

59-159-1

Impacts   ....................................................................................................................................................................................... 59-159-1

Corrective actions ................................................................................................................................................................... 59-259-2

60   [9,20] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 60-160-1

Impacts   ....................................................................................................................................................................................... 60-160-1

BTS 9100 corrective actions   .............................................................................................................................................. 60-260-2

61   [9,21] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 61-161-1

Impacts   ....................................................................................................................................................................................... 61-161-1

BTS 9100 corrective actions   .............................................................................................................................................. 61-261-2

62   [9,22] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 62-162-1

Impacts   ....................................................................................................................................................................................... 62-162-1

Corrective actions ................................................................................................................................................................... 62-262-2

63   [9,23] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 63-163-1

Impacts   ....................................................................................................................................................................................... 63-163-1

BTS 9100 corrective actions   .............................................................................................................................................. 63-263-2

64   [9,24] EXT-ALARM (Default)

Definition   .................................................................................................................................................................................. 64-164-1

Impacts   ....................................................................................................................................................................................... 64-164-1

Corrective actions ................................................................................................................................................................... 64-264-2

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xvii

Page 18: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 18/549

65   [9,25] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 65-165-1

66   [9,26] EXT-ALARM for 9110-E (Default)

Definition  ..................................................................................................................................................................................

66-166-1

67   [9,27] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 67-167-1

68   [9,28] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 68-168-1

69   [9,29] EXT-ALARM for 9110-E (Default)

Definition  ..................................................................................................................................................................................

69-169-1

70   [9,30] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 70-170-1

71   [9,31] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 71-171-1

72   [9,32] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 72-172-1

73   [9,33] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 73-173-1

74   [9,34] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 74-174-1

75   [9,35] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 75-175-1

76   [9,36] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 76-176-1

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xviii   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 19: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 19/549

77   [9,37] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 77-177-1

78   [9,38] EXT-ALARM for 9110-E (Default)

Definition  ..................................................................................................................................................................................

78-178-1

79   [9,39] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 79-179-1

80   [9,40] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 80-180-1

81   [9,41] EXT-ALARM for 9110-E (Default)

Definition  ..................................................................................................................................................................................

81-181-1

82   [9,42] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 82-182-1

83   [9,43] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 83-183-1

84   [9,44] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 84-184-1

85   [9,45] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 85-185-1

86   [9,46] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 86-186-1

87   [9,47] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 87-187-1

88   [9,48] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 88-188-1

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xix

Page 20: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 20/549

89   [9,49] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 89-189-1

90   [9,50] EXT-ALARM for 9110-E (Default)

Definition  ..................................................................................................................................................................................

90-190-1

91   [9,51] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 91-191-1

92   [9,52] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 92-192-1

93   [9,53] EXT-ALARM for 9110-E (Default)

Definition  ..................................................................................................................................................................................

93-193-1

94   [9,54] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 94-194-1

95   [9,55] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 95-195-1

96   [9,56] EXT-ALARM for 9110-E (Default)

Definition   .................................................................................................................................................................................. 96-196-1

Part VIII: Class 10: RX-TX alarms

97   [10,1] RSL-LINK 

Definition   .................................................................................................................................................................................. 97-197-1

Impacts   ....................................................................................................................................................................................... 97-197-1

BTS 9100 corrective actions   .............................................................................................................................................. 97-297-2

BTS 9110/9110-E corrective actions...............................................................................................................................

97-497-4

98   [10,3] RX-CABLE

[10,3] RX-CABLE (TRE)

Definition   .................................................................................................................................................................................. 98-198-1

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xx   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 21: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 21/549

Impacts   ....................................................................................................................................................................................... 98-198-1

Corrective actions ................................................................................................................................................................... 98-298-2

[10,3] RX-CABLE (RA)

Definition  ..................................................................................................................................................................................

98-498-4

Impacts   ....................................................................................................................................................................................... 98-498-4

Corrective actions ................................................................................................................................................................... 98-598-5

99   [10,10] TRE-VSWR 

Definition   .................................................................................................................................................................................. 99-199-1

Impacts   ....................................................................................................................................................................................... 99-199-1

BTS 9100 corrective actions   .............................................................................................................................................. 99-299-2

BTS 9110/9110-E corrective actions ............................................................................................................................... 99-499-4

Distributed BTS Corrective Actions ................................................................................................................................  99-699-6

100   [10,11] ANTENNA-VSWR-WARNING

Definition  ................................................................................................................................................................................ 100-1100-1

Impacts  ..................................................................................................................................................................................... 100-2100-2

BTS 9100 corrective actions   ............................................................................................................................................ 100-3100-3

BTS 9110-E corrective actions   ....................................................................................................................................... 100-4100-4

Distributed BTS corrective actions   ............................................................................................................................... 100-5100-5

101   [10,12] ANTENNA-VSWR-URGENT

Definition  ................................................................................................................................................................................ 101-1101-1

Impacts  ..................................................................................................................................................................................... 101-1101-1

Corrective actions   ................................................................................................................................................................ 101-2101-2

Distributed BTS corrective actions   ............................................................................................................................... 101-6101-6

102   [10,21] MODULE-FRAME-SIGNAL

[10,21] MODULE-FRAME-SIGNAL (TRE)

Definition  ................................................................................................................................................................................ 102-1102-1

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xxi

Page 22: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 22/549

Page 23: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 23/549

Impacts  ..................................................................................................................................................................................... 105-6105-6

Corrective actions   ................................................................................................................................................................ 105-6105-6

106   [10,234] IOM-DISCONNECTION

[10,234] IOM-DISCONNECTION (TRE)  .................................................................................................................

106-1106-1

Impacts  ..................................................................................................................................................................................... 106-1106-1

BTS 9100 corrective actions   ............................................................................................................................................ 106-2106-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 106-4106-4

Distributed BTS corrective actions   ............................................................................................................................... 106-6106-6

[10,234] IOM-DISCONNECTION (RA)   ................................................................................................................... 106-7106-7

Impacts  ..................................................................................................................................................................................... 106-7106-7

Corrective actions   ................................................................................................................................................................ 106-7106-7

107   [10,237] HW-DEGRADED

[10,237] HW-DEGRADED (TRE)

Definition  ................................................................................................................................................................................ 107-1107-1

Impacts  ..................................................................................................................................................................................... 107-2107-2

BTS 9100 corrective actions   ............................................................................................................................................ 107-2107-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 107-4107-4

Distributed BTS corrective actions   ............................................................................................................................... 107-6107-6

[10,237] HW-DEGRADED (RA)

Definition  ................................................................................................................................................................................ 107-7107-7

Impacts  ..................................................................................................................................................................................... 107-7107-7

BTS 9100, Alarm Number 3 corrective actions ........................................................................................................ 107-8107-8

BTS 9100, Alarm Number 4...11, 13 corrective actions  .....................................................................................

107-10107-10

BTS 9110/9110-E corrective actions .......................................................................................................................... 107-12107-12

Distributed BTS Alarm Number 14 corrective actions ........................................................................................ 107-14107-14

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xxiii

Page 24: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 24/549

108   [10,239] HW-FAILURE

[10,239] HW-FAILURE (TRE)

Definition  ................................................................................................................................................................................ 108-1108-1

Impacts  .....................................................................................................................................................................................

108-2108-2

BTS 9100, Alarm Number 1...11, 15, 16 and 18 corrective actions .................................................................. 108-3108-3

BTS 9100, Alarm Number 12 corrective actions   ..................................................................................................... 108-5108-5

BTS 9100, Alarm Number 13 corrective actions   ..................................................................................................... 108-7108-7

Micro BTS 9110/9110-E corrective actions   ............................................................................................................... 108-8108-8

[10,239] HW-FAILURE (RA)

Definition  ................................................................................................................................................................................ 108-9108-9

Impacts  ..................................................................................................................................................................................... 108-9108-9

BTS 9100, Alarm Number 2 and 12 corrective actions ....................................................................................... 108-10108-10

BTS 9100, Alarm Number 10 corrective actions ................................................................................................... 108-12108-12

BTS 9100, Alarm Number 14 corrective actions ................................................................................................... 108-14108-14

BTS 9110/9110-E corrective actions .......................................................................................................................... 108-16108-16

109   [10,248] RESTART

[10,248] RESTART (TRE)

Definition  ................................................................................................................................................................................ 109-1109-1

Impacts  ..................................................................................................................................................................................... 109-2109-2

BTS 9100 corrective actions   ............................................................................................................................................ 109-2109-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 109-4109-4

Distributed BTS corrective actions   ............................................................................................................................... 109-6109-6

[10,248] RESTART (RA)

Definition  ................................................................................................................................................................................ 109-7109-7

Impacts  ..................................................................................................................................................................................... 109-7109-7

Corrective actions   ................................................................................................................................................................ 109-8109-8

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xxiv   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 25: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 25/549

110   [10, 249] SMART-RESTART

Definition  ................................................................................................................................................................................ 110-1110-1

Impacts  ..................................................................................................................................................................................... 110-2110-2

Corrective actions  ................................................................................................................................................................

110-2110-2

Part IX: Class 11: BTS-TRANS alarms

111   [11,22] LOOP-TO-EQUIPMENT

Definition   ................................................................................................................................................................................ 111-1111-1

Impacts   ..................................................................................................................................................................................... 111-1111-1

BTS 9100 corrective actions   ............................................................................................................................................ 111-2111-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 111-3111-3

112   [11,50] LOSS-OF-INCOMING-SIGNAL

Definition  ................................................................................................................................................................................ 112-1112-1

Impacts  ..................................................................................................................................................................................... 112-1112-1

BTS 9100 corrective actions   ............................................................................................................................................ 112-2112-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 112-3112-3

113   [11,66] AIS-2M

Definition  ................................................................................................................................................................................ 113-1113-1

Impacts  ..................................................................................................................................................................................... 113-1113-1

9100 BTS corrective actions   ............................................................................................................................................ 113-2113-2

9110 Micro BTS/9110-E Micro BTS corrective actions   ....................................................................................... 113-3113-3

114   [11,81] LOSS-OF-FRAME-ALIGNMENT

Definition  ................................................................................................................................................................................ 114-1114-1

Impacts  ..................................................................................................................................................................................... 114-1114-1

BTS 9100 corrective actions   ............................................................................................................................................ 114-2114-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 114-3114-3

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xxv

Page 26: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 26/549

115   [11,86] LOSS-OF-CRC-MULTIFRAME-ALIGNMENT

Definition  ................................................................................................................................................................................ 115-1115-1

Impacts  ..................................................................................................................................................................................... 115-1115-1

BTS 9100 corrective actions  ............................................................................................................................................

 115-2115-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 115-3115-3

116   [11,99] ERROR-RATE >E-3

Definition  ................................................................................................................................................................................ 116-1116-1

Impacts  ..................................................................................................................................................................................... 116-1116-1

BTS 9100 corrective actions   ............................................................................................................................................ 116-2116-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 116-3116-3

117   [11,100] ERROR-RATE >E-4

Definition  ................................................................................................................................................................................ 117-1117-1

Impacts  ..................................................................................................................................................................................... 117-1117-1

BTS 9100 corrective actions   ............................................................................................................................................ 117-2117-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 117-3117-3

118   [11,102] ERROR-RATE >E-6

Definition  ................................................................................................................................................................................ 118-1118-1

Impacts  ..................................................................................................................................................................................... 118-1118-1

BTS 9100 corrective actions   ............................................................................................................................................ 118-2118-2

BTS 9110/9110-E corrective actions   ............................................................................................................................ 118-3118-3

119   [11,176] REMOTE-ALARM-INDICATION

Definition  ................................................................................................................................................................................ 119-1119-1

Impacts  ..................................................................................................................................................................................... 119-1119-1

9100 BTS corrective actions   ............................................................................................................................................ 119-2119-2

9110 Micro BTS/9110-E Micro BTS corrective actions   ....................................................................................... 119-3119-3

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xxvi   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 27: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 27/549

120   [11,177] PPP ALL1

Definition  ................................................................................................................................................................................ 120-1120-1

Impacts  ..................................................................................................................................................................................... 120-1120-1

Corrective actions  ................................................................................................................................................................

120-2120-2

121   [11,178] PPP NO RECEIPT OF HDLC SIGNAL

Definition  ................................................................................................................................................................................ 121-1121-1

Impacts  ..................................................................................................................................................................................... 121-1121-1

Corrective actions   ................................................................................................................................................................ 121-2121-2

122   [11,179] PPP RECEIPT OF TERMINATE

Definition  ................................................................................................................................................................................ 122-1122-1

Impacts  ..................................................................................................................................................................................... 122-1122-1

Corrective actions   ................................................................................................................................................................ 122-2122-2

123   [11,180] HDLC HIGH ERRONEOUS FRAMES RATIO

Definition  ................................................................................................................................................................................ 123-1123-1

Impacts  ..................................................................................................................................................................................... 123-1123-1

Corrective actions   ................................................................................................................................................................ 123-2123-2

124   [11,181] HDLC MEDIUM ERRONEOUS FRAMES RATIO

Definition  ................................................................................................................................................................................ 124-1124-1

Impacts  ..................................................................................................................................................................................... 124-1124-1

Corrective actions   ................................................................................................................................................................ 124-2124-2

125   [11,182] HDLC LOW ERRONEOUS FRAMES RATIO

Definition  ................................................................................................................................................................................ 125-1125-1

Impacts  ..................................................................................................................................................................................... 125-1125-1

Corrective actions   ................................................................................................................................................................ 125-2125-2

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xxvii

Page 28: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 28/549

Part X: BTS Alarm Additional Information

126   BTS Alarms with Additional Information

Overview  ................................................................................................................................................................................. 126-1126-1

[2,247]

TLV code  ................................................................................................................................................................................. 126-2126-2

[2,248]

TLV code  ................................................................................................................................................................................. 126-3126-3

127   TLV coding

Overview  ................................................................................................................................................................................. 127-1127-1

TLV 81 coding

Description  ............................................................................................................................................................................. 127-3127-3

TLV49 coding

Description  ............................................................................................................................................................................. 127-4127-4

TLV59 coding

TLV59 for TRE faults of 9100 BTS .............................................................................................................................. 127-5127-5

TLV59 for AN faults of 9100 BTS  ................................................................................................................................ 127-7127-7

TLV59 for TRANS&CLOCK faults of 9100 BTS   .................................................................................................. 127-8127-8

TLV61 coding

Definitions  .............................................................................................................................................................................. 127-9127-9

TLV82 coding

Description  ........................................................................................................................................................................... 127-11127-11

TLV83 coding

Description  ........................................................................................................................................................................... 127-13127-13

TLV84 coding

Description  ........................................................................................................................................................................... 127-15127-15

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xxviii   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 29: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 29/549

TLV120 coding

Description  ........................................................................................................................................................................... 127-16127-16

TLV243 coding

Description  ...........................................................................................................................................................................

127-17127-17

Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xxix

Page 30: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 30/549

Page 31: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 31/549

List of tables

1-1   SBL state to MO state translation  ........................................................................................................................ 1-11-1

1-2   OMC-R to LMT state change commands translation  ................................................................................... 1-21-2

2-1   Event types  ................................................................................................................................................................... 2-32-3

2-2   Alarm severity levels  ................................................................................................................................................ 2-32-3

126-1   Alarm [2,247] TLV Codes  ................................................................................................................................. 126-2126-2

126-2   Alarm [2,248] TLV Codes  ................................................................................................................................. 126-3126-3

127-1   TLV59 for TRE faults of 9100 BTS  ..............................................................................................................

 127-5127-5

127-2   TLV59 for TRANS&CLOCK faults of 9100 BTS  ................................................................................... 127-7127-7

127-3   TLV59 for TRANS&CLOCK faults of 9100 BTS  ................................................................................... 127-8127-8

127-4   TLV61 Bytes   .......................................................................................................................................................... 127-9127-9

127-5   TLV61 Board Identification Bytes for 9100 BTS  ..................................................................................... 127-9127-9

127-6   TLV83 Bytes   ........................................................................................................................................................ 127-13127-13

127-7   TLV84 Bytes   ........................................................................................................................................................ 127-15127-15

127-8   TLV120 Bytes   ..................................................................................................................................................... 127-16127-16

127-9   TLV243 Bytes   ..................................................................................................................................................... 127-17127-17

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xxxi

Page 32: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 32/549

List of tables

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xxxii   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 33: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 33/549

List of figures

5-1   MCL-FATAL-AL: BTS 9100 corrective actions   ........................................................................................... 5-25-2

5-2   MCL-FATAL-AL: BTS 9110/9110-E corrective actions   ............................................................................ 5-35-3

6-1   CLOCK-FAULT: BTS 9100 corrective actions   ............................................................................................. 6-26-2

6-2   CLOCK-FAULT: BTS 9110/9110-E corrective actions   .............................................................................. 6-36-3

7-1   MCL-XCLK: BTS 9100 corrective actions   ..................................................................................................... 7-27-2

7-2   MCL-XCLK: BTS 9110/9110-E corrective actions   ..................................................................................... 7-37-3

9-1   HW-DEGRADED: 9100 BTS, Alarm Number 1 corrective actions  ......................................................

 9-39-3

9-2   HW-DEGRADED: BTS 9100, Alarm Number 2, 3, 4, 5 and 6 corrective actions  ........................... 9-49-4

9-3   HW-DEGRADED: BTS 9100, Alarm Number 7 corrective actions  ...................................................... 9-59-5

9-4   HW-DEGRADED: 9110 Micro BTS/9110-E Micro BTS , Alarm Number 1 corrective actions

................................................................................................................................................................................. 9-69-69-6

9-5   HW-DEGRADED: 9110 Micro BTS/9110-E Micro BTS ,Alarm Number 2 corrective actions

................................................................................................................................................................................. 9-79-79-7

10-1   RESTART: BTS 9100 corrective actions   ....................................................................................................... 10-210-2

10-2   BTS 9110/9110-E corrective actions   ............................................................................................................... 10-310-3

11-1   LOSS OF TWIN CONFIGURATION corrective actions   ........................................................................ 11-211-2

12-1   RESET: Alarm Number 3 corrective actions   ................................................................................................ 12-312-3

12-2   RESET: Alarm Number 4 corrective actions   ................................................................................................ 12-412-4

12-3   RESET: Alarm Number 5 corrective actions   ................................................................................................ 12-512-5

12-4   RESET: Alarm Number 6 corrective actions   ................................................................................................ 12-512-5

12-5   RESET: Alarm Number 7 corrective actions   ................................................................................................ 12-612-6

14-1   SW-PROBLEM (CLLK): BTS 9100 corrective actions  ........................................................................... 14-314-3

14-2   SW-PROBLEM (CLLK): BTS 9110/9110-E corrective actions  ........................................................... 14-414-4

14-3   SW-PROBLEM (TRE): BTS 9100 corrective actions   .............................................................................. 14-714-7

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xxxiii

Page 34: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 34/549

14-4   SW-PROBLEM (TRE): BTS 9110/9110-E corrective actions  ............................................................... 14-814-8

14-5   SW-PROBLEM (TRE): Distributed BTS corrective actions   ............................................................... 14-1014-10

14-6   SW-PROBLEM (RA): corrective actions  .................................................................................................... 14-1314-13

15-1   TELECOM-CONFIG-FAIL: corrective actions  ..........................................................................................

 15-215-2

16-1   WRONG-CONFIGURATION (TRE): Alarm Number 1, 2, 3, 6, corrective actions   .................... 16-316-3

16-2   WRONG-CONFIGURATION (TRE): Alarm Number 4, corrective actions   ................................... 16-416-4

16-3   WRONG-CONFIGURATION (TRE): Alarm Number 5, corrective actions   ................................... 16-516-5

16-4   WRONG-CONFIGURATION (TRE): Alarm Number 7, 9, corrective actions   .............................. 16-616-6

16-5   WRONG-CONFIGURATION (TRE): Alarm Number 8, corrective actions   ................................... 16-716-7

16-6   WRONG-CONFIGURATION (TRE): Alarm Number 11, corrective actions   ................................. 16-816-8

16-7   WRONG-CONFIGURATION (TRE): Alarm Number 16, corrective actions  ................................. 16-916-9

16-8   WRONG-CONFIGURATION (TRE): Alarm Number 17, corrective actions   .............................. 16-1016-10

16-9   WRONG-CONFIGURATION (TRE): Alarm Number 18, corrective actions   .............................. 16-1116-11

16-10   WRONG-CONFIGURATION (RA): Alarm Number 2, 7, 10, corrective actions  ....................... 16-1316-13

16-11   WRONG-CONFIGURATION (RA): Alarm Number 4, corrective actions   ................................... 16-1416-14

16-12   WRONG-CONFIGURATION (RA): Alarm Number 15, Corrective Action   ................................ 16-1516-15

16-13   WRONG-CONFIGURATION (BTS): Alarm Number 12, 14, corrective actions  .......................

 16-1716-17

16-14   WRONG-CONFIGURATION (BTS): Alarm Number 13, corrective actions  ............................... 16-1816-18

17-1   CONFIG-FAIL (CLLK): BTS 9100 corrective actions   ............................................................................ 17-317-3

17-2   CONFIG-FAIL (CLLK): BTS 9110/9110-E corrective actions   ............................................................. 17-417-4

17-3   CONFIG-FAIL (RA): BTS 9100 corrective actions   .................................................................................. 17-617-6

17-4   CONFIG-FAIL (RA): BTS 9110/9110-E corrective actions   ................................................................... 17-717-7

17-5   CONFIG-FAIL (TRE): BTS 9100 corrective actions   ................................................................................ 17-917-9

17-6   CONFIG-FAIL (TRE): BTS 9110/9110-E corrective actions   .............................................................. 17-1017-10

18-1   FAN-ALARM: Corrective Actions   ................................................................................................................. 18-218-2

19-1   POWER-SUPPLY-U: corrective actions   ........................................................................................................ 19-219-2

20-1   POWER-SUPPLY-NU: corrective actions   ..................................................................................................... 20-220-2

List of figures

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xxxiv   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 35: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 35/549

Page 36: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 36/549

36-4   MODULE-INSERTED: BTS 9110/9110-E corrective actions   .............................................................. 36-936-9

37-1   REDUNDANT-CONNECTION-LOST: corrective actions   .................................................................... 37-237-2

40-1   EXT-ALARM [9,1...56] : corrective actions   ................................................................................................ 40-340-3

41-1   [9,1] EXT-ALARM: Default Corrective Actions  .......................................................................................

 41-241-2

42-1   [9,2] EXT-ALARM: Default corrective actions   .......................................................................................... 42-242-2

43-1   [9,3] EXT-ALARM: Default corrective actions   .......................................................................................... 43-343-3

43-2   [9,3] EXT-ALARM: BTS 9110/9110-E Default corrective actions   ..................................................... 43-443-4

44-1   [9,4] EXT-ALARM: Default corrective actions   .......................................................................................... 44-244-2

45-1   [9,5] EXT-ALARM: Default Corrective Actions   ....................................................................................... 45-245-2

46-1   [9,6] EXT-ALARM: Default Corrective Actions   ....................................................................................... 46-246-2

47-1   [9,7] EXT-ALARM: Default Corrective Actions   ....................................................................................... 47-247-2

48-1   [9,8] EXT-ALARM: Default Corrective Actions   ....................................................................................... 48-248-2

49-1   [9,9] EXT-ALARM: Default corrective actions   .......................................................................................... 49-249-2

50-1   [9,10] EXT-ALARM: Default corrective actions  ........................................................................................ 50-250-2

51-1   [9,11] EXT-ALARM: Default corrective actions   ........................................................................................ 51-251-2

52-1   [9,12] EXT-ALARM: Default corrective actions  ........................................................................................ 52-252-2

53-1   [9,13] EXT-ALARM: 9100 Default corrective actions  .............................................................................

 53-253-2

54-1   [9,14] EXT-ALARM: BTS 9100 Default Corrective Actions   ............................................................... 54-254-2

55-1   [9,15] EXT-ALARM: BTS 9100 Default Corrective Actions   ............................................................... 55-255-2

56-1   [9,16] EXT-ALARM: Default Corrective Actions   .................................................................................... 56-256-2

57-1   [9,17] EXT-ALARM: Default corrective actions  ........................................................................................ 57-257-2

58-1   [9,18] EXT-ALARM: Default corrective actions  ........................................................................................ 58-258-2

59-1   [9,19] EXT-ALARM: Default corrective actions  ........................................................................................ 59-259-2

60-1   [9,20] EXT-ALARM: BTS 9100 Default corrective actions   .................................................................. 60-260-2

61-1   [9,21] EXT-ALARM: BTS 9100 Default corrective actions   .................................................................. 61-261-2

62-1   [9,22] EXT-ALARM: Default corrective actions  ........................................................................................ 62-262-2

63-1   [9,23] EXT-ALARM: Default corrective actions  ........................................................................................ 63-263-2

List of figures

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xxxvi   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 37: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 37/549

64-1   [9,24] EXT-ALARM: 9100 Default Corrective Actions   ......................................................................... 64-264-2

97-1   RSL-LINK: BTS 9100 corrective actions  ...................................................................................................... 97-397-3

97-2   RSL-LINK: 9110/9110-E Micro BTS corrective actions   ......................................................................... 97-597-5

98-1   RX-CABLE (TRE):corrective actions  ............................................................................................................

 98-398-3

98-2   RX-CABLE (RA): corrective actions  .............................................................................................................. 98-698-6

99-1   TRE-VSWR: BTS 9100 corrective actions   ................................................................................................... 99-399-3

99-2   TRE-VSWR: BTS 9110/9110-E corrective actions   ................................................................................... 99-599-5

99-3   TRE-VSWR: Distributed BTS Corrective Actions   .................................................................................... 99-799-7

100-1   ANTENNA-VSWR-WARNING: Corrective Actions for 9100 BTS   ................................................ 100-3100-3

100-2   ANTENNA-VSWR-WARNING: Corrective Actions for 9110-E BTS   ........................................... 100-4100-4

100-3   ANTENNA-VSWR-WARNING: Corrective Actions for Distributed BTS   ................................... 100-5100-5

101-1   ANTENNA-VSWR-URGENT: corrective actions  .................................................................................. 101-3101-3

101-2   ANTENNA-VSWR-URGENT: Corrective Actions, continued  .......................................................... 101-4101-4

101-3   ANTENNA-VSWR-URGENT: Corrective Actions, continued  .......................................................... 101-5101-5

101-4   ANTENNA-VSWR-URGENT: Distributed BTS corrective actions   ................................................ 101-7101-7

102-1   MODULE-FRAME-SIGNAL (TRE): BTS 9100 corrective actions   ................................................ 102-3102-3

102-2   MODULE-FRAME-SIGNAL (TRE): BTS 9110/9110-E corrective actions  .................................

 102-5102-5

102-3   MODULE-FRAME-SIGNAL (RA): corrective actions   ........................................................................ 102-7102-7

103-1   MODULE-CLOCK-SIGNAL (TRE): BTS 9100 corrective actions  ................................................. 103-3103-3

103-2   MODULE-CLOCK-SIGNAL (TRE): BTS 9110/9110-E corrective actions  ................................. 103-5103-5

103-3   MODULE-CLOCK-SIGNAL: corrective actions   .................................................................................... 103-8103-8

104-1   MC-RH-NOT-REACHABLE: corrective actions   .................................................................................... 104-2104-2

105-1   MODULE-NOT-PRESENT (TRE): BTS 9100 corrective actions   .................................................... 105-3105-3

105-2   MODULE-NOT-PRESENT (TRE): BTS 9110/9110-E corrective actions  ..................................... 105-5105-5

105-3   MODULE-NOT-PRESENT (RA): corrective actions   ............................................................................ 105-7105-7

106-1   IOM-DISCONNECTION (TRE): BTS 9100 corrective actions   ........................................................ 106-3106-3

106-2   IOM-DISCONNECTION (TRE): BTS 9110/9110-E corrective actions   ........................................ 106-5106-5

List of figures

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xxxvii

Page 38: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 38/549

106-3   IOM-DISCONNECTION (TRE): Distributed BTS corrective actions   ............................................ 106-6106-6

106-4   IOM-DISCONNECTION (RA): corrective actions   ................................................................................ 106-8106-8

107-1   HW-DEGRADED (TRE): BTS 9100 corrective actions   ....................................................................... 107-3107-3

107-2   HW-DEGRADED (TRE): BTS 9110/9110-E corrective actions  ......................................................

 107-5107-5

107-3   HW-DEGRADED (TRE): Distributed BTS corrective actions   ........................................................... 107-6107-6

107-4   HW-DEGRADED (RA): BTS 9100, Alarm Number 3 corrective actions   ..................................... 107-9107-9

107-5   HW-DEGRADED (RA): BTS 9100, Alarm Number 4...11 and 13 corrective actions   ........... 107-11107-11

107-6   HW-DEGRADED (RA): BTS 9100, Alarm Number 3 corrective actions   .................................. 107-13107-13

107-7   HW-DEGRADED (RA): Distributed BTS, Alarm Number 14 corrective actions   ................... 107-15107-15

108-1   HW-FAILURE (TRE): 9100 BTS, Alarm Number 1...11, 15, 16 and 18 corrective actions  .... 108-4108-4

108-2   HW-FAILURE (TRE): 9100 BTS, Alarm Number 12 corrective actions   ....................................... 108-6108-6

108-3   HW-FAILURE (TRE): 9100 BTS, Alarm Number 13 corrective actions   ....................................... 108-7108-7

108-4   HW-FAILURE (TRE): 9110 Micro BTS/9110-E Micro BTS corrective actions   ......................... 108-8108-8

108-5   HW-FAILURE (RA): BTS 9100, Alarm Number 2 and 12 Corrective Actions   ........................ 108-11108-11

108-6   HW-FAILURE (RA): BTS 9100, Alarm Number 10 corrective actions   ....................................... 108-13108-13

108-7   HW-FAILURE (RA): BTS 9100, Alarm Number 14 corrective actions   ....................................... 108-15108-15

108-8   HW-FAILURE (RA): BTS 9110/9110-E corrective actions  ..............................................................

 108-17108-17

109-1   RESTART (TRE): BTS 9100 corrective actions  ....................................................................................... 109-3109-3

109-2   RESTART (TRE): BTS 9110/9110-E corrective actions   ....................................................................... 109-5109-5

109-3   RESTART (TRE): Distributed BTS corrective actions   .......................................................................... 109-6109-6

109-4   RESTART (RA): corrective actions  ............................................................................................................... 109-9109-9

111-1   LOOP-TO-EQUIPMENT: BTS 9100 corrective actions   ....................................................................... 111-2111-2

111-2   LOOP-TO-EQUIPMENT: BTS 9110/9110-E corrective actions   ....................................................... 111-3111-3

112-1   LOSS-OF-INCOMING-SIGNAL: BTS 9100 corrective actions   ....................................................... 112-2112-2

112-2   LOSS-OF-INCOMING-SIGNAL: BTS 9110/9110-E corrective actions   ....................................... 112-3112-3

113-1   AIS-2M: 9100 BTS corrective actions   ......................................................................................................... 113-2113-2

113-2   AIS-2M: 9110 Micro BTS/9110-E Micro BTS corrective actions  ..................................................... 113-3113-3

List of figures

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xxxviii   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 39: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 39/549

114-1   LOSS-OF-FRAME-ALIGNMENT: BTS 9100 corrective actions   .................................................... 114-2114-2

114-2   LOSS-OF-FRAME-ALIGNMENT: BTS 9110/9110-E corrective actions  ..................................... 114-3114-3

115-1   LOSS-OF-CRC-MULTIFRAME-ALIGNMENT: BTS 9100 corrective actions   ......................... 115-2115-2

115-2   LOSS-OF-CRC-MULTIFRAME-ALIGNMENT: BTS 9110/9110-E corrective actions  ..........

 115-3115-3

116-1   ERROR-RATE>E-3: BTS 9100 corrective actions   ................................................................................. 116-2116-2

116-2   ERROR-RATE>E-3: BTS 9110/9110-E corrective actions   .................................................................. 116-3116-3

117-1   ERROR-RATE>E-4: BTS 9100 corrective actions   ................................................................................. 117-2117-2

117-2   ERROR-RATE>E-4: BTS 9110/9110-E corrective actions   .................................................................. 117-3117-3

118-1   ERROR-RATE>E-6: BTS 9100 corrective actions   ................................................................................. 118-2118-2

118-2   ERROR-RATE>E-6: BTS 9110/9110-E corrective actions   .................................................................. 118-3118-3

119-1   9100 BTS corrective actions  ............................................................................................................................. 119-2119-2

119-2   9110 Micro BTS/9110-E Micro BTS corrective actions   ........................................................................ 119-3119-3

120-1   PPP ALL1: corrective actions   .......................................................................................................................... 120-2120-2

121-1   PPP NO RECEIPT OF HDLC SIGNAL: corrective actions   ................................................................ 121-2121-2

122-1   PPP RECEIPT OF TERMINATE: corrective actions   ............................................................................. 122-2122-2

123-1   PPP HIGH ERRONEOUS FRAMES RATIO: corrective actions   ...................................................... 123-2123-2

124-1   PPP MEDIUM ERRONEOUS FRAMES RATIO: corrective actions  .............................................

 124-2124-2

125-1   PPP LOW ERRONEOUS FRAMES RATIO: corrective actions  ....................................................... 125-2125-2

List of figures

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xxxix

Page 40: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 40/549

List of figures

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xl   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 41: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 41/549

About this documentAbout this document

Purpose

The purpose of the alarm dictionary is to provide the operator with a structured method

for handling alarm messages generated by the BTS.

This document contains a list of all BTS alarms, and the actions required to remove them.

Alarms are displayed at the OMC-R terminal and at the LMT to inform the operator of system faults.

Note: When a fault occurs, a number of alarms can be generated simultaneously. These

alarms must be analyzed as a group to determine the precise fault.

Reason for reissue

Issue number Reason for reissue

4 The following sections were updated:

  Chapter 26, “[5,32] FATAL TEMPERATURE”•   Chapter 25, “[5,31] TEMPERATURE-WARNING”

•   Chapter 104, “[10,39] MC-RH-NOT-REACHABLE”

•   Chapter 108, “[10,239] HW-FAILURE”

•   Chapter 107, “[10,237] HW-DEGRADED”

3 Improvements done in Chapter 99, “[10,10] TRE-VSWR”

2 The section Chapter 107, “[10,237] HW-DEGRADED” is updated

due to introduction of MC-TRDU fan alarms.

Improvements done in Chapter 31, “[8,4] IGNORE PLUGGED

BUT NOT USABLE EQUIPMENT” due to “Handling of up to 4E1 in TDM and 36TRX per SUMX” feature introduction.

1 First official release of the document for B12.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

xli

Page 42: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 42/549

Intended audience

This document is aimed at telecommunications operators responsible for performing

O&M fault handling and troubleshooting tasks.

Supported systems

This document applies to release B12 of the BSS.

How to use this document

The operator must be familiar with the following:

•   Alcatel-Lucent O&M concepts for the BSS

•   Fault management

•   Use of OMC-R and BTS NEM

•   SBL hierarchies of the BTS

  Telecommunications techniques including line transmission and switching.

How to comment

To comment on this document, go to the  Online Comment Form (http://infodoc.alcatel-

lucent.com/comments/) or e-mail your comments to the Comments Hotline

([email protected]).

 About this document

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

xlii   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 43: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 43/549

Part I: Introduction to the BTS

alarm dictionary

Overview

Purpose

This alarm dictionary provides additional information that is not displayed in the alarm

messages sent to the OMC-R, BSC or TSS terminals.The dictionary contains alarm definitions for each alarm type produced by the BSS.

Each definition describes the:

•   Alarm description

•   Impact on System

•   Methods for further fault isolation

•   Corrective actions.

The descriptions of the alarms in this document is MO based for OMC -R terminal

 purpose. For BTS LMT purpose, the SBL related information is added in brackets if 

applicable.

Contents

Chapter 1, Relationships Between SBLs and MOs 1-1

Chapter 2, 9153 OMC-R Alarm Surveillance information 2-1

Chapter 3, LMT alarm messages 3-1

Chapter 4, BTS alarm information 4-1

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

I-1

Page 44: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 44/549

Page 45: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 45/549

Page 46: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 46/549

Page 47: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 47/549

Page 48: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 48/549

Relationships Between SBLs and MOs   Mapping table

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

1-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 49: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 49/549

2   29153 OMC-R Alarm

Surveillance information

Introduction

Alarm Surveillance

Overview

In the Alarm Surveillance of the 9153 OMC-R efficient means to control, supervise and

manage equipment problems in the MFS are provided.

Alarms or Alarm notifications consist of messages sent by network resources that have

detected problems or failures in the network. These alarms are displayed in lists while

alarm counters keep track of statistics. By clicking on an alarm in the list, the operator 

gets detailed information. FM displays information as described below.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

2-1

Page 50: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 50/549

Object identification

Description

Overview

The Object Identification identifies the resource that raised the alarm.

Object identification gives information about:

•   The resource type (Object Class)

•   The resource name (Friendly Name). For a board, the Friendly Name also shows the

 board's location by rack, shelf and slot. For BTS 9100 outdoor only: If the alarm

message displays the RIT location A,0,0, the RIT is located in the COMI/CODI side

compartment.

9153 OMC-R Alarm Surveillance informationObject identification

Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

2-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 51: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 51/549

Alarm type

Overview

Alarm type information

The Alarm Type identifies the type of problem the alarm refers to.

This information is sub-divided into:

•   evenType: Table 2-1, “Event types” (p. 2-3) describes the five evenTypes

•   probable Cause

•   perceived Severity: Table 2-2, “Alarm severity levels” (p. 2-3) gives the severity level

of the alarm. describes the severity levels.

Event types

Table 2-1 Event types

evenType Indicates....

Communication a problem with a procedure or process used to convey information from one point to another in

the network.

Quality of Service degradation in the quality of service in the network.

Processing Error a software or processing fault.

Equipment an equipment fault.

Environmental a problem in the enclosure containing the equipment.

Alarm severity levels

Table 2-2 Alarm severity levels

Severity Level Indicates...

Critical a serious fault condition which requires immediate corrections. Example: a managed object

goes out of service.

Major a fault condition which requires urgent correction action. Example: severe degradation in the

operation of a managed object.

Minor a fault condition which does not affect service but corrective action should be taken to avoid a

more serious fault.

Warning detection of a potential fault condition.Action should be taken to diagnose and correct the

 problem to avoid a more serious fault condition.

Indeterminate the severity level cannot be defined by the resource which raised the alarm.

Cleared the alarm was cleared by the resource which raised the alarm.

9153 OMC-R Alarm Surveillance information Alarm type

Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

2-3

Page 52: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 52/549

In addition the Object Identification and Alarm Type information, all alarms always give

the date and time of the alarm. An alarm may also contain optional information, such as

the notification id. Refer to the FM on-line help for more detailed information on FM.

9153 OMC-R Alarm Surveillance information Alarm type

Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

2-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 53: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 53/549

3   3LMT alarm messages

Overview

Information

General

The format of Alarms displayed at a LMT differs from that in the OMC-R.

For more information about the BTS LMT see BTS NEM User Guide.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

3-1

Page 54: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 54/549

BTS LMT alarm message parameters

Introduction

Description

Depending on the type of alarm and in which window it is viewed, an alarm message

contains all or most of the parameters listed in this section.

Message Identity

The identity number given to the alarm message stored in the database.

Event Time

The time the message was issued at its source or received at the BTS LMT.

Classification

The characteristics of the alarm, consisting of:

•   Alarm Class name and number - as shown in the Alarm Dictionary

•   Alarm Type name and number - as shown in the Alarm Dictionary

•   Alarm Number - dependent on the Alarm Class and Type. See the appropriate

dictionary entry for the valid alarm numbers for a particular alarm

•   Alarm Condition - has one of the following values:

 – begin - alarm on. For fatal failures, the affected SBL changes state to FLT or FOS.For non-fatal failures, the affected SBL changes state to FIT

 – end - alarm off. Indicates the successful recovery of the system. The affected SBL

may not change state if other alarms related to the SBL are on

 – event - occurrence of anomaly. No action is required unless it occurs frequently.

Event alarms are of short duration and the affected SBL does not change state.

The system retry/recovery mechanism has cleared the fault.

Location

The origin of the alarm, consisting of:

•   Unit type

•   Unit number 

•   SBL type

•   SBL number and subnumber, if appropriate.

LMT alarm messagesBTS LMT alarm message parameters

Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

3-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 55: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 55/549

SBL states

If a fatal alarm occurs and the affected SBL changes state to FOS, the system isolates the

faulty equipment if it cannot be initialized. After a repair action, the operator normally

initializes the equipment.

If a fatal alarm occurs and the affected SBL changes state to FLT, the system resets the

faulty equipment. When the alarm ceases, the system automatically initializes the

equipment.

If a non-fatal alarm or event occurs, the affected SBL's are put into the FIT state. In the

worst situation, the equipment operates in a degraded mode.

An SBL has one of the following (current) states:

•   IT

•   FIT

•   Faulty

•   EF•   FOS

•   OPR 

•   SOS

•   WTC

•   UT

•   NEQ

•   MSD

•   MSD AUTO

Refer to the document  Alcatel-Lucent OAM - Operations & Maintenance Principles for a

description of the states.

Suspected RIT

The information for the suspected RIT is displayed if the system is able to determine the

location of the fault.

The information consists of:

•   Unit type

  Unit number •   RIT type

•   Physical location - the position of the RIT board within the cabinet, defined for the

rack, shelf and slot. For BTS 9100 outdoor BTS only: If the alarm message displays

the RIT location A,0,0, the RIT is located in the COMI/CODI side compartment.

LMT alarm messagesBTS LMT alarm message parameters

Introduction

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

3-3

Page 56: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 56/549

If more than one RIT is shown in the list, the RIT most likely to be causing the fault is

indicated. Replace this RIT first and initialize it. If the fault persists, replace another RIT

from the list and initialize it.

Additional Information

Some alarms provide additional information. If the additional information is displayed as

a text message, the original information from the BSS has been decoded.

If the additional information is not decoded, it is displayed as pairs of hexadecimal digits.

At the BTS NEM, the additional information consists of numbers in the range 0 to 255.

Each number represents the contents of one pair of digits.

Decoding additional information digits is described in section Part X: “BTS Alarm

Additional Information”.

Note: Decoding Additional Information from Alarms

Decoding BTS or BSC additional information must only be attempted byAlcatel-Lucent support personnel.

If a fault persists after corrective actions have been taken, send a copy of the alarm

message containing the additional information to the Alcatel-Lucent support office.

LMT alarm messagesBTS LMT alarm message parameters

Introduction

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

3-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 57: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 57/549

4   4BTS alarm information

Overview

Purpose

This section describes the definition of alarms as they appear on the OMC-R and the

alarm description given in the document.

Contents

Alarm Definition 4-2

specific Problems 4-2

eventType 4-2

 probable Cause 4-3

 perceived Severity 4-3

Alarm Description 4-4

Banner 4-4

Alarm Description 4-4

Impact on System 4-4

Corrective actions 4-5

Additional Information 4-7

Description 4-7

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

4-1

Page 58: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 58/549

Page 59: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 59/549

probable Cause

Description

This attribute defines the probable cause of the alarm. Its value belongs to a set of 

 possible values either defined in recommendation X.721, M3100 and GSM 11.12 or defined for a particular Telecommunication Management Network (TMN) project.

perceived Severity

Description

This attribute defines six severity levels. The severity levels indicate how the capability of 

the managed object is affected.

The levels are:

•   Critical: indicates that an immediate corrective action is required. This severity is

reported, when a managed object becomes totally out of service and its capability

must be restored.

•   Major: indicates that an urgent corrective action is required. This severity is reported,

when there is a severe degradation in the capability of the managed object and its full

capability must be restored.

•   Minor: indicates a non-service affecting fault condition and that corrective action

should be taken in order to prevent a more serious fault. This severity is reported,

when the detected alarm condition is not currently degrading the capacity of the

managed object.

•   Warning: indicates a potential or impending fault, before any significant effect have

 been felt. Action(s) should be taken to further diagnose (if necessary) and correct the

 problem in order to prevent it from becoming a more serious service affecting fault.

•   Indeterminate: indicates that the severity level cannot be defined by the resource

raising the alarm.

•   Cleared: indicates the clearing of one or more previously alarms for this managed

object with the same Alarm type, Probable Cause and Specific problems (if given).

BTS alarm information Alarm Definition

probable Cause

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

4-3

Page 60: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 60/549

Alarm Description

Banner

Description

Each BSS alarm definition starts with an identification banner which allows the location

of the appropriate definition. It takes the form:

[7,246] FU CONFIG-FAIL

Alarm Description

DescriptionAlarm Description describes the alarm and, where appropriate, the differences to the

default perceived severities and alarm numbers.

Impact on System

Description

The description of the impact on Telecom and O&M system contains a table indicating

which part of the system is affected by the fault in terms of loss, degradation or none.For example, if a cell is affected, the cell column in the table contains a check (X) in

either the Loss or Degradation row. For different impact cases (redundancy, diversity,

etc.) other symbols are used.

The table shows the worst case, even though redundancy may be provided.

BTS alarm information Alarm Description

Banner

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

4-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 61: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 61/549

Corrective actions

Description

To solve the current alarm a graphical workflow chart is used. It shows the required

 procedures by checks, tests and actions to determine the fault and finally to solve thealarm.

Checks, tests and thus resulting corrective actions are provided with a priority on remote

at the OMC-R and then by service on-site, to minimize the maintenance effort.

Graphical view

By clicking on a dedicated action field, a link to the detailed description of the task will

 be opened.

BTS alarm information Alarm Description

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

4-5

Page 62: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 62/549

Page 63: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 63/549

Additional Information

Description

Decoding of the additional information

Section Part X: “BTS Alarm Additional Information” describes the decoding of the

additional information.

Some alarms provide additional information. If the additional information is displayed as

a text message, the original information from the BSS has been decoded.

If the additional information is not decoded, it is displayed as pairs of hexadecimal digits.

At the BSC terminal, the additional information consists of numbers in the range 0 to 255.

Each number represents the contents of one pair of digits.

Note: Decoding Additional Information from Alarms

Decoding BSC additional information must only be attempted by Alcatel-Lucent

support personnel.

If a fault persists after corrective actions have been taken, send a copy of the alarm

message containing the additional information to the Alcatel-Lucent support office.

BTS alarm information Additional Information

Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

4-7

Page 64: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 64/549

BTS alarm information   Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

4-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 65: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 65/549

Part II: Class 1: CLK alarms

Overview

Purpose

This section defines the Class 1, CLK alarms.

Contents

Chapter 5, [1,6] MCL-FATAL-AL 5-1

Chapter 6, [1,12] CLOCK-FAULT 6-1

Chapter 7, [1,31] MCL-XCLK 7-1

Chapter 8, [1,234] IOM-DISCONNECTION 8-1

Chapter 9, [1,237] HW-DEGRADED 9-1

Chapter 10, [1,248] RESTART 10-1

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

II-1

Page 66: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 66/549

Class 1: CLK alarms   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

II-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 67: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 67/549

5   5[1,6] MCL-FATAL-AL

Definition

Description

specific Problems   MCL-FATAL-AL

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA)

Alarm Description   Fatal internal alarm on the Clock Unit.

Alarm Number 1: Module faulty with unknown cause due to access failure

2: The internal clock is defective

4: Fault on the clock signal is detected by other module

5: Autorestart failure

Impacts

Description

If the CLLK is redundant on this BTS, the telecom functions are not affected.

If no redundancy is available however, the cell(s) fed by the reporting CLLK are lost.

BTS 9100: There is no clock redundancy available, so the cells fed by the reporting CLLK are lost, thus the BTS is lost.

Impact BSS Cell(s) Signaling Calls

Loss - X(no red.) X (no red.)   X (no red.)

Degradation X (no red.)   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

5-1

Page 68: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 68/549

Page 69: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 69/549

BTS 9110/9110-E corrective actions

Corrective Actions

Figure 5-2 MCL-FATAL-AL: BTS 9110/9110-E corrective actions

[1,6] MCL-FATAL-AL   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

5-3

Page 70: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 70/549

[1,6] MCL-FATAL-AL   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

5-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 71: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 71/549

6   6[1,12] CLOCK-FAULT

Definition

Description

specific Problems   CLOCK-FAULT

event Type   Equipment

probable Cause   Timing Problem

perceived Severity   Major (PMA), Minor (DMA)

Alarm Description Major (PMA)/Minor (DMA) : Fault on the clock signals detected by several clock users in the

BTS (e.g. FHU, CU, FU).

Major (PMA) : If the CLLK alarm disappears and the OMU loses the alarm information, this

alarm is sent by the OMU as a dummy alarm. It indicates that the CLLK is FOS and requires

operator initialization.

If the alarm has unknown cause, it indicates that more detailed alarms were reported before and

are available at OMC-R.

Impacts

Description

If the clock system is redundant on this BTS, the telecom functions are not affected.

If, however, no redundancy is available, the channels supported by the CLLK/CLDB are lost.

BTS 9100: There is no clock redundancy available, so the cells fed by the reporting CLLK are lost, thus the BTS is lost.

Impact BSS Cell(s) Signaling Calls

Loss - X (no red.) X (no red.)   X (no red.)

Degradation X (no red.)   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

6-1

Page 72: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 72/549

BTS 9100 corrective actions

Description

Figure 6-1 CLOCK-FAULT: BTS 9100 corrective actions

[1,12] CLOCK-FAULT    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

6-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 73: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 73/549

BTS 9110/9110-E corrective actions

Description

Figure 6-2 CLOCK-FAULT: BTS 9110/9110-E corrective actions

[1,12] CLOCK-FAULT    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

6-3

Page 74: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 74/549

Page 75: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 75/549

7   7[1,31] MCL-XCLK

Definition

Description

specific Problems   MCL-XCLK 

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA)

Alarm Description   An error has been detected in the input of the External Reference Clock.

Alarm Number 1 : Loss of input signal clock from external reference clock, in slave mode.

2 : Loss of Frame Number input, in slave mode.

3 : Loss of Frame Signal, in slave mode.

Impacts

Description

If the CLLK is redundant on this BTS the telecom functions are not affected.

If, however, no redundancy is available, the cell(s) fed by the reporting CLLK are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X (no red.) X (no red.)   X (no red.)

Degradation X (no red.)   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

7-1

Page 76: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 76/549

BTS 9100 corrective actions

Description

Figure 7-1 MCL-XCLK: BTS 9100 corrective actions

[1,31] MCL-XCLK    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

7-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 77: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 77/549

BTS 9110/9110-E corrective actions

Description

Figure 7-2 MCL-XCLK: BTS 9110/9110-E corrective actions

[1,31] MCL-XCLK    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

7-3

Page 78: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 78/549

[1,31] MCL-XCLK    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

7-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 79: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 79/549

Page 80: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 80/549

corrective actions

Description

Contact your Alcatel-Lucent system support.

[1,234] IOM-DISCONNECTION    corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

8-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 81: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 81/549

9   9[1,237] HW-DEGRADED

Definition

Description

specific Problems   HW-DEGRADED

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Minor (DMA), Warning (MI)

Alarm Description   The processing of the clock is degraded.

Alarm Number 1: The PCM synchronization is not available.

2: The GPS synchronization is lost.

3: GPS module failure.

4: GPS antenna failure.

5: GPS LNA failure.

6: Not enough satellites are visible.

7: Frequency synchronization is lost.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

9-1

Page 82: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 82/549

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - -   - -

Degradation   -   - - -

Required tools and materials :

•   PCM test tools

•   GPS test tools

•   Replacement tools, see appropriate replacement procedure.

[1,237] HW-DEGRADED   Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

9-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 83: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 83/549

9100 BTS, Alarm Number 1 corrective actions

Description

Figure 9-1 HW-DEGRADED: 9100 BTS, Alarm Number 1 corrective actions

[1,237] HW-DEGRADED   9100 BTS, Alarm Number 1 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

9-3

Page 84: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 84/549

9100 BTS, Alarm Number 2, 3, 4 , 5 and 6 corrective actions

Description

Figure 9-2 HW-DEGRADED: BTS 9100, Alarm Number 2, 3, 4, 5 and 6 corrective

actions

[1,237] HW-DEGRADED   9100 BTS, Alarm Number 2, 3, 4 , 5 and 6 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

9-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 85: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 85/549

Page 86: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 86/549

Page 87: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 87/549

9110 Micro BTS/9110-E Micro BTS, Alarm Number 2 correctiveactions

Description

Figure 9-5 HW-DEGRADED: 9110 Micro BTS/9110-E Micro BTS ,Alarm Number 2corrective actions

[1,237] HW-DEGRADED   9110 Micro BTS/9110-E Micro BTS, Alarm Number 2corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

9-7

Page 88: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 88/549

Page 89: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 89/549

10   10[1,248] RESTART

Definition

Description

specific Problems   RESTART

event Type   Processing Error 

probable Cause   Application Subsystem Failure

perceived Severity   Warning (MI)

Alarm Description   The TRANSandCLOCK has performed a successful autorestart.

Alarm Number 1 : A fatal exception has occurred on a LP, or a LP SW error is detected in operational state.

2 : A watchdog reset has occurred.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - -   - -

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

10-1

Page 90: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 90/549

BTS 9100 corrective actions

Description

Figure 10-1 RESTART: BTS 9100 corrective actions

[1,248] RESTART    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

10-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 91: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 91/549

BTS 9110/9110-E corrective actions

Description

Figure 10-2 BTS 9110/9110-E corrective actions

[1,248] RESTART    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

10-3

Page 92: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 92/549

[1,248] RESTART    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

10-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 93: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 93/549

Part III: Class 2: OMU Alarms

Overview

Purpose

This section defines the alarms for the Class 2: OMU alarm class.

Contents

Chapter 11, [2,1] LOSS OF TWIN CONFIGURATION 11-1

Chapter 12, [2,247] RESET 12-1

Chapter 13, [2,248] RESTART 13-1

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

III-1

Page 94: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 94/549

Class 2: OMU Alarms   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

III-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 95: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 95/549

Page 96: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 96/549

Page 97: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 97/549

12   12[2,247] RESET

Description

Definition

specific Problems   RESET

event Type   Processing Error 

probable Cause   softwareProgramAbnomallyTerminated

perceived Severity   Warning (MI)

Alarm Description   An OMU reset is performed. The Alarm Number indicates the reason for the reset.

During the reset procedure, the OMU had a BTS software download and started its operational

software. It distributed the configuration data to all BTSs and rebuilt its internal database.

Alarm Number 3: Triggered by Watchdog (any reason).

4: External scenario failure.

5: Lack of internal resources.

6: Internal scenario time out.7: Microprocessor exception.

8: Mains alarm end.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

12-1

Page 98: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 98/549

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - -   - X(1)

Degradation   -   - - -

Notes:

1. Only in case of distributed BTS

[2,247] RESET    Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

12-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 99: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 99/549

Alarm Number 3 corrective actions

Description

The hardware is faulty or there is a bug in the software. If only one BTS is concerned or 

the alarm occurs repeatedly, replace the faulty hardware.

Figure 12-1 RESET: Alarm Number 3 corrective actions

[2,247] RESET    Alarm Number 3 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

12-3

Page 100: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 100/549

Alarm Number 4 corrective actions

Description

The communication with the BSC is disturbed.

Figure 12-2 RESET: Alarm Number 4 corrective actions

[2,247] RESET    Alarm Number 4 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

12-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 101: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 101/549

Alarm Number 5 corrective actions

Description

There is a problem with the memory allocation.

Alarm Number 6 corrective actions

Description

The OMU detects a problem in the running OMU software and attempts to it clean up.

Figure 12-3 RESET: Alarm Number 5 corrective actions

Figure 12-4 RESET: Alarm Number 6 corrective actions

[2,247] RESET    Alarm Number 5 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

12-5

Page 102: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 102/549

Alarm Number 7 corrective actions

Description

An interrupt caused by an address or by a bus problem.

If the alarm occurs repeatedly:

Figure 12-5 RESET: Alarm Number 7 corrective actions

[2,247] RESET    Alarm Number 7 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

12-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 103: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 103/549

Alarm Number 8 corrective actions

Description

The power supply is again available for the BTS.

[2,247] RESET    Alarm Number 8 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

12-7

Page 104: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 104/549

[2,247] RESET    Alarm Number 8 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

12-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 105: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 105/549

13   13[2,248] RESTART

Description

Definition

specific Problems   RESTART

event Type   Processing Error 

probable Cause   Application Subsystem Failure

perceived Severity   Warning (MI)

Alarm Description   An OMU restart is performed successfully. The reason for the restart is indicated in the Alarm

 Number field.

During the restart procedure the OMU has restarted its software, distributed its configuration

data to all BTS units, and re-built its internal database.

Alarm Number 1: Lack of internal resources, allocating the memory.

2: Triggered for OMU-CPF replacement.

3: The OMU detects an internal scenario time out in the running OMU software, and attempts

to clean it up.

4: Microprocessor exception - an interrupt is caused by an address or a bus problem.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - -   - X(1)

Degradation   -   - - -

Notes:

1. Only in case of distributed BTS

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

13-1

Page 106: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 106/549

corrective actions

Description

 None.

If the problem persists, a reset is triggered automatically.

[2,248] RESTART    corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

13-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 107: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 107/549

Part IV: Class 3: SW-AN Alarms

Overview

Purpose

This section defines the alarms for the Class 3: SW-AN alarm class.

Contents

Chapter 14, [3,11] SW-PROBLEM 14-1

Chapter 15, [3,13] TELECOM-CONFIG-FAIL 15-1

Chapter 16, [3,14] WRONG-CONFIGURATION 16-1

Chapter 17, [3,246] CONFIG-FAIL 17-1

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

IV-1

Page 108: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 108/549

Class 3: SW-AN Alarms   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

IV-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 109: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 109/549

14   14[3,11] SW-PROBLEM

[3,11] SW-PROBLEM (CLLK)

Definition

Description

specific Problems   SW-PROBLEM

event Type   Processing Error 

probable Cause   software Program Abnormally Terminated

perceived Severity   Nbr 1...3:Major (PMA)

 Nbr 4, 5: Minor (DMA), Warning (MI)

Alarm Description   The software is corrupted or bad.

Alarm Number 1: Error detected during the configuration with saved parameters in initialization state: saved

 parameters are corrupted and cannot be used for the auto-restart sequence.

2: Error detected during the SW activation procedure in the fault localization state, or a

check-sum error is detected in operational state.

3: A fatal exception has occurred on LP, or a LP SW error is detected in a state other than the

operational state.

4: An error has occurred during the SW activation procedure, triggered by the OMU in the

initialization state. The alarm is not fatal because the TRANS&CLOCK uses the previous FW.

5: An error has occurred which is linked to a software download. The error was detected during

the downloading procedure from the OMU in initialization state (packet sequence, global file

checksum). This alarm is not fatal because the TRANS&CLOCK uses the previous FW.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

14-1

Page 110: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 110/549

Impacts

Description

If the CLLK is redundant on this BTS, the telecom functions are not affected.

For the BTS 9100: there is no clock redundancy available, so the cells fed by the reporting CLLK are lost, thus the BTS is lost.

Impact BSS Cell(s) Signaling Calls

Loss - X (no red.) X (no red.)   X (no red.)

Degradation X (no red.)   - - -

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (CLLK)

Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

14-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 111: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 111/549

Page 112: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 112/549

BTS 9110/9110-E corrective actions

Description

Figure 14-2 SW-PROBLEM (CLLK): BTS 9110/9110-E corrective actions

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (CLLK)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

14-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 113: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 113/549

[3,11] SW-PROBLEM (TRE)

Definition

Description

specific Problems   SW-PROBLEM

event Type   Processing Error 

probable Cause   software Program Abnormally Terminated

perceived Severity   Major (PMA), Warning (MI)

Alarm Description   The software is corrupted or bad.

Alarm Number 1: An error is detected during the configuration with saved parameters in initialization state:

saved parameters are corrupted and cannot be used for the auto-restart sequence.

Major (PMA): The local recovery fails.

Warning (MI): The local recovery is successful.

2: An error is detected during the SW activation procedure in the fault localization state or 

check-sum error detected in operational state.

Major (PMA): The local recovery fails.

Warning (MI): The local recovery is successful.

3: A fatal exception occurred on SCP or a SCP, the software error is detected in another state

than the operational state.

Major (PMA): The local recovery fails.

Warning (MI): The local recovery is successful.

4: An error detected during the software activation procedure, triggered by the OMU in

initialization state.

5: An error is linked to software down-load. The error is detected during the down-loading

 procedure from the SUM, in initialization state (packet sequence, global file check-sum, etc.).

6: A watchdog has occurred and an auto-restart has failed.

7: A bad parameter is detected in the TRE CPF.

8: LRA triggered on G3 TRE as consequence of SCP RTF supervision algoritm.

10: LRA triggered on G5 TRE as consequence of SCP supervision algorithm for consecutive

failing of assignments on a certain time slot of a TRE.

17: MC-RRH Protocol Error 

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (TRE)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

14-5

Page 114: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 114/549

Impacts

Description

The TRE is no longer usable. The associated eight channels are lost. Independent of frequency hopping or not, the BSC reduces the

number of channels supported by the cell.If the TRE supporting the BCCH is not concerned, the cell is degraded, calls are lost. (#).

If the TRE supporting the BCCH is concerned and there is BCCH redundancy, recovery mechanisms regain the cell's functionality. (*).

If the TRE supporting the BCCH is concerned and there is no BCCH redundancy, the complete cell is lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X (no red.) X (no red.)   X (no red.)#*

Degradation X (no red.)   #* - -

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (TRE)

Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

14-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 115: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 115/549

Figure 14-3 SW-PROBLEM (TRE): BTS 9100 corrective actions

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (TRE)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

14-7

Page 116: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 116/549

BTS 9110/9110-E corrective actions

Description

Figure 14-4 SW-PROBLEM (TRE): BTS 9110/9110-E corrective actions

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (TRE)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

14-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 117: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 117/549

Distributed BTS corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (TRE)

Distributed BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

14-9

Page 118: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 118/549

Figure 14-5 SW-PROBLEM (TRE): Distributed BTS corrective actions

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (TRE)

Distributed BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

14-10   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 119: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 119/549

Page 120: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 120/549

Corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (RA)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

14-12   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 121: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 121/549

Figure 14-6 SW-PROBLEM (RA): corrective actions

[3,11] SW-PROBLEM[3,11] SW-PROBLEM (RA)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

14-13

Page 122: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 122/549

[3,11] SW-PROBLEM   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

14-14   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 123: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 123/549

15   15[3,13] TELECOM-CONFIG-

FAIL

Definition

Description

specific Problems   TELECOM-CONFIG-FAIL

event Type   Processing Error 

probable Cause   Configuration Or Customization Error 

perceived Severity   Warning (MI)

Alarm Description   A Telecom Configuration Parameter error has been detected.

Alarm Number 1: There is a rejection of the telecom configuration parameters related to Hand-Over and Power 

Control (parameters included in BS_POWER_CONTROL, MS_POWER_CONTROL or 

PREPROCESS_CONFIGURE messages) in the operational state.

A message is missing in the list of telecom messages received.

2: The TLC_CONFIG_T timer (supervision of reception of telecom configuration on RSL) has

elapsed after an O&M configuration or re-configuration.

3: Incorrect sys info 3 parameters have been received in the operational state.

4: Inconsistent telecom configuration messages have been received from the BSC after an

O&M reconfiguration.

5: No correct BCCH info messages have been received from the BSC after an O&M

reconfiguration.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

15-1

Page 124: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 124/549

Impacts

Description

Telecom functions are not affected. The old configuration is still running.

Impact BSS Cell(s) Signaling Calls

Loss - -   - -

Degradation   -   - - -

Corrective actions

Description

Figure 15-1 TELECOM-CONFIG-FAIL: corrective actions

[3,13] TELECOM-CONFIG-FAIL   Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

15-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 125: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 125/549

16   16[3,14] WRONG-

CONFIGURATION

[3,14] WRONG-CONFIGURATION (TRE)

Definition

Description

specific Problems   WRONG-CONFIGURATION

event Type   Processing Error 

probable Cause   Configuration Or Customization Error 

perceived Severity   Major (PMA)

Alarm Description   The parameters are not consistent with the capacity of the equipment.

Alarm Number 1: The CDM radio definition per TS is inconsistent with the hopping type.

2: The CDM frequency range is inconsistent with the actual frequency range.

3: The CDM cell range is inconsistent with the extended cell support.

4: There are files missing in SUM memory for a given module type.

5: The RSL rate between CDM and Abis is inconsistent.

6: The CDM capability is inconsistent with the actual capability.

7: A bad parameter is detected in configuration data.

8: There is no RSL/TCH mapping available for the TRE.

9: The RSL mapping is wrong, the TRE does not support a RSL on the indicated Abis interface.

11: The TRE does not support the required PS capabilities.

16: The bandwidth per MC-module is larger than the ‘PA RF BW’.

17: Wrong OML/RSL multiplexing rule.

18: The multi-carrier class is not compatible with the multi-carrier class capability.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

16-1

Page 126: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 126/549

Impacts

Description

The TRE is no longer usable. The associated eight channels are lost. Independent of frequency hopping or not, the BSC reduces the

number of channels supported by the cell.If the TRE supporting the BCCH is not concerned, the cell is degraded, calls are lost. (#).

If the TRE supporting the BCCH is concerned and there is BCCH redundancy, recovery mechanisms regain the cell's functionality, calls

are lost. (*)

If the TRE supporting the BCCH is concerned and there is no BCCH redundancy, the complete cell is lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X (no red.) X (no red.)   X (no red.)#*

Degradation X (no red.)   #* - -

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (TRE)

Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

16-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 127: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 127/549

Alarm Number 1, 2, 3, 6, corrective actions

Description

Figure 16-1 WRONG-CONFIGURATION (TRE): Alarm Number 1, 2, 3, 6, correctiveactions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (TRE)

Alarm Number 1, 2, 3, 6, corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

16-3

Page 128: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 128/549

Alarm Number 4, corrective actions

Description

Figure 16-2 WRONG-CONFIGURATION (TRE): Alarm Number 4, corrective actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (TRE)

Alarm Number 4, corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

16-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 129: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 129/549

Alarm Number 5, corrective actions

Description

Figure 16-3 WRONG-CONFIGURATION (TRE): Alarm Number 5, corrective actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (TRE)

Alarm Number 5, corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

16-5

Page 130: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 130/549

Alarm Number 7, 9, corrective actions

Description

Figure 16-4 WRONG-CONFIGURATION (TRE): Alarm Number 7, 9, corrective actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (TRE)

Alarm Number 7, 9, corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

16-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 131: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 131/549

Alarm Number 8, corrective actions

Description

Figure 16-5 WRONG-CONFIGURATION (TRE): Alarm Number 8, corrective actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (TRE)

Alarm Number 8, corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

16-7

Page 132: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 132/549

Alarm Number 11, corrective actions

Description

Figure 16-6 WRONG-CONFIGURATION (TRE): Alarm Number 11, corrective actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (TRE)

Alarm Number 11, corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

16-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 133: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 133/549

Page 134: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 134/549

Description

Alarm Number 18, corrective actions

Figure 16-8 WRONG-CONFIGURATION (TRE): Alarm Number 17, corrective actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (TRE)

Alarm Number 17, corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

16-10   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 135: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 135/549

Description

Figure 16-9 WRONG-CONFIGURATION (TRE): Alarm Number 18, corrective actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (TRE)

Alarm Number 18, corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

16-11

Page 136: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 136/549

[3,14] WRONG-CONFIGURATION (RA)

Definition

Description

specific Problems   WRONG-CONFIGURATION

event Type   Processing Error 

probable Cause   Configuration Or Customization Error 

perceived Severity   Nbr. 2: Major (PMA)

 Nbr. 4, 7, 10: Minor (DMA), Warning (MI)

Alarm Description   The parameters are not consistent with the capacity of the equipment.

Alarm Number 2: The CDM frequency range is inconsistent with the actual frequency range.

4: There are files missing in OMU memory for a given module type.

7: A bad parameter is detected in configuration data.

The sector cannot provide the required maximum output power (SBL state FIT, severity DMA).

10:

•   The sector cannot provide the required maximum output power (SBL state FIT, severity

DMA)

•   In case of cell shared, the power of secondary is lower than the one of the main sector.

•   In unbalanced TRX output power configuration, at least one of the TREs of this sector 

cannot provide the requested output power.

15: Antenna Hopping not supported.

Impacts

Description

The quality of transmission is degraded.

Impact BSS Cell(s) Signaling Calls

Loss - -   - -

Degradation   -   - X X

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (RA)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

16-12   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 137: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 137/549

Alarm Number 2, 7, 10 corrective actions

Description

Figure 16-10 WRONG-CONFIGURATION (RA): Alarm Number 2, 7, 10, corrective

actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (RA)

Alarm Number 2, 7, 10 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

16-13

Page 138: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 138/549

Alarm Number 4 corrective actions

Description

Figure 16-11 WRONG-CONFIGURATION (RA): Alarm Number 4, corrective actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (RA)

Alarm Number 4 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

16-14   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 139: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 139/549

Alarm Number 15 corrective actions

Description

Figure 16-12 WRONG-CONFIGURATION (RA): Alarm Number 15, Corrective Action

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (RA)

Alarm Number 15 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

16-15

Page 140: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 140/549

[3,14] WRONG-CONFIGURATION (BTS)

Definition

Description

specific Problems   WRONG-CONFIGURATION

event Type   Processing Error 

probable Cause   Configuration Or Customization Error 

perceived Severity   Minor (DMA), Warning (MI)

Alarm Description   The parameters are not consistent with the capacity of the equipment.

Alarm Number 12: A configuration with 2 PCM links is not supported.

13: The OML is not on Abis 1.

14: The configuration via the Qmux is not allowed with 2 PCM links.

Impacts

Description

There is no impact.

Impact BSS Cell(s) Signaling Calls

Loss - -   - -

Degradation   -   - - -

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (BTS)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

16-16   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 141: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 141/549

Alarm Number 12, 14 corrective actions

Description

Figure 16-13 WRONG-CONFIGURATION (BTS): Alarm Number 12, 14, corrective

actions

[3,14] WRONG-CONFIGURATION [3,14] WRONG-CONFIGURATION (BTS)

Alarm Number 12, 14 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

16-17

Page 142: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 142/549

Page 143: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 143/549

17   17[3,246] CONFIG-FAIL

[3,246] CONFIG-FAIL (CLLK)

Definition

Description

specific Problems   CONFIG-FAIL

event Type   Processing Error 

probable Cause   Configuration Or Customization Error 

perceived Severity   Nbr 1: Major (PMA))

 Nbr 3, 4: Minor (DMA), Warning (MI)

Alarm Description   There is a scenario-failure for TRANS&CLOCK.

Alarm Number 1: An error in the initialization or re-configuration is detected, due to the absence of an answer 

to the message "OMU, UNKNOWN_MESSAGE, inconvenient sub-state".

3: A SW downloading or SW activation failure is detected by the OMU, due to the absence of 

an answer to the message "OMU. UNKNOWN_MESSAGE, inconvenient sub -state". This

alarm is not fatal because the TRANS&CLOCK uses the previous SW.

4: A transmission configuration failure is detected by the OMU due to no answer to the OMU,

an UNKNOWN MESSAGE or an inconvenient substate. This alarm has no fatal consequences,

 because the TRANS&CLOCK will use the previous transmission settings.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

17-1

Page 144: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 144/549

Impacts

Description

If the CLLK is redundant on this BTS, the telecom functions are not affected.

For the BTS 9100: there is no clock redundancy available, so the cells fed by the reporting CLLK are lost, thus the BTS is lost.

Impact BSS Cell(s) Signaling Calls

Loss - X (no red.) X (no red.)   X (no red.)

Degradation X (no red.)   - - -

[3,246] CONFIG-FAIL[3,246] CONFIG-FAIL (CLLK)

Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

17-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 145: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 145/549

BTS 9100 corrective actions

Description

Figure 17-1 CONFIG-FAIL (CLLK): BTS 9100 corrective actions

[3,246] CONFIG-FAIL[3,246] CONFIG-FAIL (CLLK)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

17-3

Page 146: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 146/549

BTS 9110/9110-E corrective actions

Description

Figure 17-2 CONFIG-FAIL (CLLK): BTS 9110/9110-E corrective actions

[3,246] CONFIG-FAIL[3,246] CONFIG-FAIL (CLLK)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

17-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 147: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 147/549

Page 148: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 148/549

BTS 9100 corrective actions

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

Figure 17-3 CONFIG-FAIL (RA): BTS 9100 corrective actions

[3,246] CONFIG-FAIL[3,246] CONFIG-FAIL (RA)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

17-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 149: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 149/549

BTS 9110/9110-E corrective actions

Description

Figure 17-4 CONFIG-FAIL (RA): BTS 9110/9110-E corrective actions

[3,246] CONFIG-FAIL[3,246] CONFIG-FAIL (RA)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

17-7

Page 150: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 150/549

[3,246] CONFIG-FAIL (TRE)

Definition

Description

specific Problems   CONFIG-FAIL

event Type   Processing Error 

probable Cause   Configuration Or Customization Error 

perceived Severity   Major (PMA)

Alarm Description   There is a scenario failure for TRE.

An error in the initialization is detected due to no answer to OMU, UNKNOWN_MESSAGE,

inconvenient sub-state.

Impacts

Description

The TRE is no longer usable. The associated eight channels are lost. Independent of frequency hopping or not, the BSC reduces the

number of channels supported by the cell.

If the TRE supporting the BCCH is not concerned, the cell is degraded, calls are lost. (#).

If the TRE supporting the BCCH is concerned and there is BCCH redundancy, recovery mechanisms regain the cell's functionality, calls

are lost. (*).

If the TRE supporting the BCCH is concerned and there is no BCCH redundancy, the complete cell is lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X (no red.) X (no red.)   X (no red.)#*

Degradation X (no red.)   #* - -

[3,246] CONFIG-FAIL[3,246] CONFIG-FAIL (TRE)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

17-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 151: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 151/549

BTS 9100 corrective actions

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

Figure 17-5 CONFIG-FAIL (TRE): BTS 9100 corrective actions

[3,246] CONFIG-FAIL[3,246] CONFIG-FAIL (TRE)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

17-9

Page 152: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 152/549

BTS 9110/9110-E corrective actions

Description

Figure 17-6 CONFIG-FAIL (TRE): BTS 9110/9110-E corrective actions

[3,246] CONFIG-FAIL[3,246] CONFIG-FAIL (TRE)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

17-10   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 153: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 153/549

[3,246] CONFIG-FAIL   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

17-11

Page 154: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 154/549

[3,246] CONFIG-FAIL   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

17-12   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 155: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 155/549

Part V: Class 5: ENVIR Alarms

Overview

Purpose

This section defines the alarms for the Class 5: ENVIR alarm class.

Contents

Chapter 18, [5,1] FAN-ALARM 18-1

Chapter 19, [5,11] POWER-SUPPLY-U 19-1

Chapter 20, [5,12] POWER-SUPPLY-NU 20-1

Chapter 21, [5,13] CONTROL-UNIT-AL 21-1

Chapter 22, [5,20] MAINS-AL 22-1

Chapter 23, [5,23] POWER-SHUTDOWN 23-1

Chapter 24, [5,24] SUBRACK-POWER 24-1

Chapter 25, [5,31] TEMPERATURE-WARNING 25-1

Chapter 26, [5,32] FATAL TEMPERATURE 26-1

Chapter 27, [5, 40] CPRI_LINK_PROBLEM 27-1

Chapter 28, [5,237] HW-DEGRADED 28-1

Chapter 29, [5,239] HW-FAILURE 29-1

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

V-1

Page 156: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 156/549

Class 5: ENVIR Alarms   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

V-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 157: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 157/549

18   18[5,1] FAN-ALARM

Definition

Description

specific Problems   FAN-ALARM

event Type   Environmental

probable Cause   Heating Or Ventilation Or Cooling System Problem

perceived Severity   Minor (PMA)

Alarm Description   A single fan is faulty - this is a warning, not yet critical.

5 : FAN alarm for 9110-E BTS (Master).

10 : FAN alarm for 9110-E BTS (Slave 1).

20 : FAN alarm for 9110-E BTS (Slave 2).

11 : FAN alarm for 9110-E BTS (Slave 11).

12 : FAN alarm for 9110-E BTS (Slave 12).

21 : FAN alarm for 9110-E BTS (Slave 21).22 : FAN alarm for 9110-E BTS (Slave 22).

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - -   - -

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

18-1

Page 158: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 158/549

Corrective actions

Description

Figure 18-1 FAN-ALARM: Corrective Actions

[5,1] FAN-ALARM   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

18-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 159: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 159/549

19   19[5,11] POWER-SUPPLY-U

Definition

Description

specific Problems   POWER-SUPPLY-U

event Type   Equipment

probable Cause   PowerProblem

perceived Severity   Critical (VPMA), Warning (MI)

Alarm Description   At least two power supply modules have failed or Green Power source is in power restriction.

Some TRE are switched OFF autonomously by the BTS.

BTS 9100 (G3): At least one PM08/PM11 module is operational.

BTS 9100 (G4): If PM12/PM18 used: The BTS uses the backup batteries and the available

PM12/PM18 modules.

Impacts

Description

During a defined delay, the configuration is kept, the Telecom functions are not affected.

After the end of the previous delay, a minimal configuration is selected with the TRE supporting the BCCH. (#).

If the battery is empty, the cells are lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X X   # X

Degradation   # X # - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

19-1

Page 160: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 160/549

Corrective actions

Description

Figure 19-1 POWER-SUPPLY-U: corrective actions

[5,11] POWER-SUPPLY-U    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

19-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 161: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 161/549

20   20[5,12] POWER-SUPPLY-NU

Definition

Description

specific Problems   POWER-SUPPLY-NU

event Type   Equipment

probable Cause   PowerProblem

perceived Severity   Major (PMA)

Alarm Description   A power supply module has failed, but the BTS is still supplied by other power supply modules

in parallel.

BTS 9100: At least one PM08/PM11/PM12/PM18 module is operational and no TRE is

switched OFF.

ImpactsDescription

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - -   - -

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

20-1

Page 162: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 162/549

Corrective actions

Description

Figure 20-1 POWER-SUPPLY-NU: corrective actions

[5,12] POWER-SUPPLY-NU    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

20-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 163: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 163/549

21   21[5,13] CONTROL-UNIT-AL

Definition

Description

specific Problems   CONTROL-UNIT-AL

event Type   Equipment

probable Cause   PowerProblem

perceived Severity   Nbr 2: Critical (VPMA), Warning (MI)

 Nbr 1: Major (PMA), Warning (MI)

Alarm Description   There is a failure of the control unit that supervises the power modules.

Alarm Number 1: The battery capacity is faulty.

2: The battery charging voltage is faulty.

Impacts

Description

The battery is empty and is not used: the Telecom functions are not affected.

The battery is empty and is used: the cells are lost. (X)

Impact BSS Cell(s) Signaling Calls

Loss - X X X

Degradation X - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

21-1

Page 164: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 164/549

Page 165: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 165/549

22   22[5,20] MAINS-AL

Definition

Description

specific Problems   MAINS-AL

event Type   Equipment

probable Cause   PowerProblem

perceived Severity   Critical (VPMA), Warning (MI)

Alarm Description   There is a problem on the BTS mains power supply. No BTS PM08/PM11/PM12/PM18 power 

supply is operational. The BTS runs on the backup batteries.

Impacts

Description

During a defined delay, the configuration is kept, the Telecom functions are not affected.

After the end of the previous delay, a minimal configuration is selected with the TRE supporting the BCCH. (#)

If the battery is empty, the cells are lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X X #X

Degradation #X # - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

22-1

Page 166: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 166/549

Corrective actions

Description

Figure 22-1 MAINS-AL: corrective actions

[5,20] MAINS-AL   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

22-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 167: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 167/549

Page 168: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 168/549

Alarm Number 1 corrective actions

Description

Figure 23-1 POWER-SHUTDOWN: Alarm Number 1 corrective actions

[5,23] POWER-SHUTDOWN    Alarm Number 1 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

23-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 169: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 169/549

Alarm Number 2 corrective actions

Description

Figure 23-2 POWER-SHUTDOWN: Alarm Number 2 corrective actions

[5,23] POWER-SHUTDOWN    Alarm Number 2 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

23-3

Page 170: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 170/549

[5,23] POWER-SHUTDOWN    Alarm Number 2 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

23-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 171: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 171/549

24   24[5,24] SUBRACK-POWER

Definition

Description

specific Problems   SUBRACK-POWER 

event Type   Equipment

probable Cause   PowerProblem

perceived Severity   Major (PMA)

Alarm Description   This alarm is reported if more than one module of the subrack has power supply problems.

Alarm Number 1: Subrack number 1.

...

n: Subrack number n.

Impacts

Description

There is impact through the HW_FAILURE of class 10 alarms.

Impact BSS Cell(s) Signaling Calls

Loss - X X X

Degradation X - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

24-1

Page 172: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 172/549

Corrective actions

Description

Figure 24-1 SUBRACK-POWER: corrective actions

[5,24] SUBRACK-POWER   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

24-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 173: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 173/549

Page 174: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 174/549

Corrective actions

Description

Note: Required tools and materials

•   Thermometer •   Replacement and cleaning tools, see appropriate replacement procedure.

[5,31] TEMPERATURE-WARNING[5,31] TEMPERATURE-WARNING (BTS)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

25-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 175: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 175/549

Figure 25-1 TEMPERATURE-WARNING (BTS): corrective actions

[5,31] TEMPERATURE-WARNING[5,31] TEMPERATURE-WARNING (BTS)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

25-3

Page 176: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 176/549

[5,31] TEMPERATURE-WARNING (TRE)

Definition

Description

specific Problems   TEMPERATURE-WARNING

event Type   Environmental

probable Cause   Temperature Unacceptable

perceived Severity   Major (PMA), Warning (MI)

Alarm Description   This is a temperature warning.

A MTRE inside the BTS has reached a temperature which is close to the shut off temperature.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

Corrective actions

Note: Required tools and materials

•   Thermometer 

•   Replacement and cleaning tools, see appropriate replacement procedure.

[5,31] TEMPERATURE-WARNING[5,31] TEMPERATURE-WARNING (TRE)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

25-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 177: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 177/549

Figure 25-2 TEMPERATURE-WARNING (TRE): corrective actions

[5,31] TEMPERATURE-WARNING[5,31] TEMPERATURE-WARNING (TRE)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

25-5

Page 178: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 178/549

[5,31] TEMPERATURE-WARNING   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

25-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 179: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 179/549

26   26[5,32] FATAL

TEMPERATURE

Definition

Description

specific Problems   FATAL TEMPERATURE

event Type   Environmental

probable Cause   Temperature Unacceptable

perceived Severity   Major (PMA)

Alarm Description   This is a fatal temperature alarm.

Internal TRE temperature is higher than the predefined high threshold. The power amplifier of 

the TRE automatically switches itself off, in order to avoid any HW damage.

Impacts

Description

The TRE is no longer usable. The associated eight channels are lost. Independent of frequency hopping or not, the BSC reduces the

number of channels supported by the cell.

If the TRE supporting the BCCH is not concerned, the cell is degraded, calls are lost. (#).

If the TRE supporting the BCCH is concerned and there is BCCH redundancy, recovery mechanisms regain the cell's functionality, calls

are lost. (*)

If the TRE supporting the BCCH is concerned and there is no BCCH redundancy, the complete cell is lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X (no red.) X (no red.) X(no red.)#*

Degradation X (no red.) #* - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

26-1

Page 180: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 180/549

Corrective actions

Note: Required tools and materials

•   Thermometer 

•   Replacement and cleaning tools, see appropriate replacement procedure.

Figure 26-1 FATAL TEMPERATURE: corrective actions

[5,32] FATAL TEMPERATURE    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

26-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 181: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 181/549

27   27[5, 40] CPRI_LINK_PROB-

LEM

Definition

Description

specific Problems   CPRI_LINK_PROBLEM

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Minor (DMA)

Alarm Description   A Layer 1 problem on the CPRI link connection at the slave port has been detected by the TRE.

 No communication to the Other Standard Function (3G/4G) possible.

Corrective actions

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

27-1

Page 182: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 182/549

Description

Figure 27-1 CPRI_LINK_PROBLEM: corrective actions

[5, 40] CPRI_LINK_PROBLEM   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

27-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 183: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 183/549

28   28[5,237] HW-DEGRADED

[5,237] HW-DEGRADED (BTS)

Definition

Description

specific Problems   HW-DEGRADED

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA), Warning (MI)

Alarm Description   A problem has been detected on the XIOB/OUTC input ports.

Alarm Number 6: DC/DC converter 1 failure.

7: DC/DC converter 2 failure.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

28-1

Page 184: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 184/549

Corrective actions

Description

Figure 28-1 HW-DEGRADED (BTS): corrective actions

[5,237] HW-DEGRADED[5,237] HW-DEGRADED (BTS)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

28-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 185: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 185/549

[5,237] HW-DEGRADED (EACB)

Definition

Description

specific Problems   HW-DEGRADED

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA)

Alarm Description   A problem has been detected on the input ports

Alarm Number 10:BTS 9100: A problem has been detected on the XIOB/OUTC input ports. BTS 9110/9110-E

: A problem has been detected on the input ports during tests with the MBTS-BCB unit.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

Alarm Number 10 BTS 9100 corrective actions

[5,237] HW-DEGRADED[5,237] HW-DEGRADED (EACB)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

28-3

Page 186: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 186/549

Description

Figure 28-2 HW-DEGRADED (EACB): BTS 9100 corrective actions

[5,237] HW-DEGRADED[5,237] HW-DEGRADED (EACB)

Alarm Number 10 BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

28-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 187: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 187/549

Alarm Number 10 BTS 9110/9110-E corrective actions

Description

Figure 28-3 HW-DEGRADED (EACB): BTS 9110/9110-E corrective actions

[5,237] HW-DEGRADED[5,237] HW-DEGRADED (EACB)

Alarm Number 10 BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

28-5

Page 188: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 188/549

[5,237] HW-DEGRADED (RA)

Definition

Description

specific Problems   HW-DEGRADED

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA)

Alarm Description   A problem has been detected on the input ports

Alarm Number 11: TMA current supervision failure

12: TMA1 current too low

13: TMA1 current too high

14: TMA1 short circuit alarm

15: TMA2 current too low

16: TMA2 current too high

17: TMA2 short circuit alarm

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

[5,237] HW-DEGRADED[5,237] HW-DEGRADED (RA)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

28-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 189: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 189/549

Page 190: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 190/549

[5,237] HW-DEGRADED (CCF)

Definition

Description

specific Problems   HW-DEGRADED

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Minor (DMA), Warning (MI)

Alarm Description   An fan control for front or back row is faulty.

Alarm Number 1:The complete front row of the fans is faulty. This is detected when either all front fans

generate an alarm or the DC converter of the fan control board is faulty.

2:Same as 1, but for the back row instead of the front row.

3:At least one fan on a left fan unit is faulty.

4:At least one fan on a middle fan unit is faulty.

5:At least one fan on a right fan unit is faulty.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

[5,237] HW-DEGRADED[5,237] HW-DEGRADED (CCF)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

28-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 191: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 191/549

Corrective actions

Description

Figure 28-5 HW-DEGRADED (CCF): corrective actions

[5,237] HW-DEGRADED[5,237] HW-DEGRADED (CCF)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

28-9

Page 192: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 192/549

[5,237] HW-DEGRADED   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

28-10   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 193: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 193/549

29   29[5,239] HW-FAILURE

[5,239] HW-FAILURE (EACB)

Definition

Description

specific Problems   HW-FAILURE

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA)

Alarm Description   A hardware failure has been detected.

Alarm Number 2: This alarm have an unknown cause and indicates that more detailed alarms were reported

 before and are available in the OMC.

3: The BCB detects a malfunction or the extraction of the module.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

29-1

Page 194: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 194/549

Alarm Number 2 corrective actions

Description

Figure 29-1 HW-FAILURE (EACB): Alarm Number 2 corrective actions

[5,239] HW-FAILURE [5,239] HW-FAILURE (EACB)

Alarm Number 2 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

29-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 195: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 195/549

Alarm Number 3 corrective actions

Description

Figure 29-2 HW-FAILURE (EACB): Alarm Number 3 corrective actions

[5,239] HW-FAILURE [5,239] HW-FAILURE (EACB)

Alarm Number 3 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

29-3

Page 196: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 196/549

[5,239] HW-FAILURE (CCF)

Definition

Description

specific Problems   HW-FAILURE

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA)

Alarm Description   There is a failure of front and back FAN (e.g. due to power supply failure) or the alarm has an

unknown cause. This alarm indicates that more detailed alarms were reported before and are

available in the OMC.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

Corrective actions

[5,239] HW-FAILURE [5,239] HW-FAILURE (CCF)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

29-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 197: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 197/549

Description

Figure 29-3 HW-FAILURE (CCF): corrective actions

[5,239] HW-FAILURE [5,239] HW-FAILURE (CCF)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

29-5

Page 198: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 198/549

Page 199: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 199/549

Part VI: Class 8: Global BTS

alarms

Overview

Purpose

This section defines the alarms for the Class 8: Global BTS alarms class.

Contents

Chapter 30, [8,3] RESYNCH 30-1

Chapter 31, [8,4] IGNORE PLUGGED BUT NOT USABLE EQUIPMENT 31-1

Chapter 32, [8,5] TOO MANY PLUGGED MODULES 32-1

Chapter 33, [8,8] HW-RESYNCH 33-1

Chapter 34, [8,30] BCB-LINK 34-1

Chapter 35, [8,31] IOM-LINK 35-1

Chapter 36, [8,32] MODULE-INSERTED 36-1

Chapter 37, [8,40] REDUNDANT-CONNECTION-LOST 37-1

Chapter 38, [8,247] RESET (BTS) 38-1

Chapter 39, [8,248] RESTART 39-1

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

VI-1

Page 200: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 200/549

Class 8: Global BTS alarms   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

VI-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 201: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 201/549

30   30[8,3] RESYNCH

Definition

Description

specific Problems   RESYNCH

event Type   Processing Error 

probable Cause   Configuration Or Customization Error 

perceived Severity   Warning (MI)

Alarm Description   Discrepancies are detected between the BSC and OMU database and both databases have been

updated. The OMC-R triggers an update of its own Alarms in Force and SBL state list.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

30-1

Page 202: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 202/549

Corrective actions

 None required, the BTS is in service.

[8,3] RESYNCH    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

30-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 203: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 203/549

31   31[8,4] IGNORE PLUGGED

BUT NOT USABLE

EQUIPMENT

Definition

Description

specific Problems   IGNORE PLUGGED BUT NOT USABLE EQUIPMENT

event Type   Processing Error 

probable Cause   Configuration Or Customization Error 

perceived Severity   Warning (MI)

Alarm Description   Discrepancies are detected between the BSC and OMU database and both databases have been

updated.

The OMC-R triggers an update of its own Alarms in Force and SBL state list.

Alarm Number 1:

The operator has installed and configured too many TREs, although there are G3 TREs in the

BTS.

SUMA/SUMP: Equipment over 12 TREs is ignored.

SUMX: Equipment over 12 TREs is ignored, but only G3 TREs, and the minimum of G3 TREs

in order to keep the maximum number of Twin TRXs or MC modules.

2:

The operator has installed and configured 3 Abis links or 4 Abis links, although there are G3 or 

G4 TREs in the BTS (not ‘up to 4 E1’ capable modules).

G3/G4 equipment is ignored.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

31-1

Page 204: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 204/549

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

Corrective actions

[8,4] IGNORE PLUGGED BUT NOT USABLE EQUIPMENT    Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

31-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 205: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 205/549

Description

Figure 31-1 IGNORE PLUGGED BUT NOT USABLE EQUIPMENT: corrective actions

[8,4] IGNORE PLUGGED BUT NOT USABLE EQUIPMENT    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

31-3

Page 206: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 206/549

[8,4] IGNORE PLUGGED BUT NOT USABLE EQUIPMENT    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

31-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 207: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 207/549

32   32[8,5] TOO MANY PLUGGED

MODULES

Definition

Description

specific Problems   TOO MANY PLUGGED MODULES

event Type   Equipment

probable Cause   Configuration Or Customization Error 

perceived Severity   Warning (MI)

Alarm Description   The installed HW configuration exceeds the power dissipation limits.

Alarm Number 1: Too many TREs are plugged in the rack type.

Impacts

Description

There is no disturbance of the telecom applications.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

32-1

Page 208: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 208/549

Corrective actions

Description

Figure 32-1 TOO MANY PLUGGED MODULES: corrective actions

[8,5] TOO MANY PLUGGED MODULES   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

32-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 209: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 209/549

33   33[8,8] HW-RESYNCH

Definition

Description

specific Problems   HW-RESYNCH

event Type   Processing Error 

probable Cause   Configuration Or Customization Error 

perceived Severity   Warning (MI)

Alarm Description   The BTS detects an addition or reduction in SBLs or hardware modification (different RIT

names). Consequently a hardware re-synchronization alarm is sent. This causes the OMC-R to

trigger a hardware, state and alarm audit. The audit aligns the OMC -R database with the new

hardware.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

33-1

Page 210: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 210/549

Corrective actions

Description

 None required, the BTS is in service.

[8,8] HW-RESYNCH    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

33-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 211: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 211/549

34   34[8,30] BCB-LINK

[8,30] BCB-LINK (BTS)

Definition

Description

specific Problems   BCB-LINK 

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA), Warning (MI)

Alarm Description   There is no communication on IOM link.

Alarm Number 1: The BCB link is unable to detect the presence of the modules.

2: The BCB Power supply is faulty.

Impacts

Description

The is no communication on the BCB.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

34-1

Page 212: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 212/549

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[8,30] BCB-LINK [8,30] BCB-LINK (BTS)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

34-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 213: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 213/549

Figure 34-1 BCB-LINK: BTS 9100 corrective actions

[8,30] BCB-LINK [8,30] BCB-LINK (BTS)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

34-3

Page 214: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 214/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[8,30] BCB-LINK [8,30] BCB-LINK (BTS)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

34-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 215: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 215/549

Figure 34-2 BCB-LINK (BTS): BTS 9110/9110-E corrective actions

[8,30] BCB-LINK [8,30] BCB-LINK (BTS)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

34-5

Page 216: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 216/549

Page 217: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 217/549

Page 218: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 218/549

[8,30] BCB-LINK    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

34-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 219: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 219/549

35   35[8,31] IOM-LINK

Definition

Description

specific Problems   IOM-LINK 

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA)

Alarm Description   There is no communication on IOM link.

Impacts

Description

There is no disturbance of the telecom applications.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

35-1

Page 220: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 220/549

BTS 9100 corrective actions

Description

Figure 35-1 IOM-LINK: BTS 9100 corrective actions

[8,31] IOM-LINK    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

35-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 221: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 221/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[8,31] IOM-LINK    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

35-3

Page 222: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 222/549

Figure 35-2 IOM-LINK: BTS 9110/9110-E corrective actions

[8,31] IOM-LINK    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

35-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 223: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 223/549

36   36[8,32] MODULE-INSERTED

[8,32] MODULE-INSERTED (BTS)

Definition

Description

specific Problems   MODULE-INSERTED

event Type   Equipment

probable Cause   Replaceable Unit Problem

perceived Severity   Warning (MI)

Alarm Description   The TRE is not connected to any ANX/ANC via RF cable.

Impacts

Description

There is no disturbance of the telecom applications.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

36-1

Page 224: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 224/549

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[8,32] MODULE-INSERTED[8,32] MODULE-INSERTED (BTS)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

36-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 225: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 225/549

Figure 36-1 MODULE-INSERTED: BTS 9100 corrective actions

[8,32] MODULE-INSERTED[8,32] MODULE-INSERTED (BTS)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

36-3

Page 226: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 226/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[8,32] MODULE-INSERTED[8,32] MODULE-INSERTED (BTS)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

36-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 227: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 227/549

Figure 36-2 MODULE-INSERTED: BTS 9110/9110-E corrective actions

[8,32] MODULE-INSERTED[8,32] MODULE-INSERTED (BTS)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

36-5

Page 228: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 228/549

[8,32] MODULE-INSERTED (RA)

Definition

Description

specific Problems   MODULE-INSERTED

event Type   Equipment

probable Cause   Replaceable Unit Problem

perceived Severity   Warning (MI)

Alarm Description   The inserted TRE is connected to a dedicated ANx via RF cable.

Impacts

Description

There is no disturbance of the telecom applications.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[8,32] MODULE-INSERTED[8,32] MODULE-INSERTED (RA)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

36-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 229: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 229/549

Figure 36-3 MODULE-INSERTED: BTS 9100 corrective actions

[8,32] MODULE-INSERTED[8,32] MODULE-INSERTED (RA)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

36-7

Page 230: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 230/549

Page 231: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 231/549

Page 232: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 232/549

Page 233: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 233/549

37   37[8,40] REDUNDANT-

CONNECTION-LOST

Definition

Description

specific Problems   RESET

event Type   Processing Error 

probable Cause   Software Error 

perceived Severity   Minor (DMA)

Alarm Description   Loss of redundant connection on HSE/HSO between MC-modules and SUM. Most probably

the failure is the SFP or the optical link.

Alarm Number 1: Loss of redundant connection on HSE/HSO between MC-modules and SUM. Most probably

the failure is the SFP or the optical link.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

37-1

Page 234: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 234/549

Corrective actions

Description

Figure 37-1 REDUNDANT-CONNECTION-LOST: corrective actions

[8,40] REDUNDANT-CONNECTION-LOST    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

37-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 235: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 235/549

Page 236: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 236/549

Corrective actions

Description

 None required, the BTS is now in service.

[8,247] RESET (BTS)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

38-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 237: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 237/549

Page 238: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 238/549

Corrective actions

Description

 None required.

[8,248] RESTART    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

39-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 239: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 239/549

Part VII: Class 9: BTS-EXTERNAL

alarms

Overview

Purpose

This section defines the alarms for the Class 9: BTS-EXTERNAL alarms.

Contents

Chapter 40, [9,1...56] EXT-ALARM 40-1

Chapter 41, [9,1] EXT-ALARM (Default) 41-1

Chapter 42, [9,2] EXT-ALARM (Default) 42-1

Chapter 43, [9,3] EXT-ALARM (Default) 43-1

Chapter 44, [9,4] EXT-ALARM (Default) 44-1

Chapter 45, [9,5] EXT-ALARM (Default) 45-1

Chapter 46, [9,6] EXT-ALARM (Default) 46-1

Chapter 47, [9,7] EXT-ALARM (Default) 47-1

Chapter 48, [9,8] EXT-ALARM (Default) 48-1

Chapter 49, [9,9] EXT-ALARM (Default) 49-1

Chapter 50, [9,10] EXT-ALARM (Default) 50-1

Chapter 51, [9,11] EXT-ALARM (Default) 51-1

Chapter 52, [9,12] EXT-ALARM (Default) 52-1

Chapter 53, [9,13] EXT-ALARM (Default) 53-1

Chapter 54, [9,14] EXT-ALARM (Default) 54-1

Chapter 55, [9,15] EXT-ALARM (Default) 55-1

Chapter 56, [9,16] EXT-ALARM (Default) 56-1

Chapter 57, [9,17] EXT-ALARM (Default) 57-1

Chapter 58, [9,18] EXT-ALARM (Default) 58-1

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

VII-1

Page 240: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 240/549

Page 241: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 241/549

Chapter 92, [9,52] EXT-ALARM for 9110-E (Default) 92-1

Chapter 93, [9,53] EXT-ALARM for 9110-E (Default) 93-1

Chapter 94, [9,54] EXT-ALARM for 9110-E (Default) 94-1

Chapter 95, [9,55] EXT-ALARM for 9110-E (Default) 95-1

Chapter 96, [9,56] EXT-ALARM for 9110-E (Default) 96-1

Class 9: BTS-EXTERNAL alarms   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

VII-3

Page 242: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 242/549

Class 9: BTS-EXTERNAL alarms   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

VII-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 243: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 243/549

40   40[9,1...56] EXT-ALARM

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   External Alarms are not linked to telecom part of the BTS, they are forseen to announce events

linked to the environment of the BTS.

BTS 9100/9110/9110-E: External alarm (e.g., door open, fire, water) detected from input port [1

... 24].

External alarms [25 ... 56] can be raised only by the BTS 9110-E, and are applicable only in this

case.

For Outdoor BTS, some of the 24 external alarms are allocated to the cabinet, they are already

wired and reflect behaviour of other elements in the BTS: AC main, Air Conditioning unit,door...

For 9100 Indoor BTS, the 24 external alarms are free (customer).

For Distributed BTS external alarms [1...8] are used.

External alarms are seen only at the BTS and BSC terminals. At the OMC-R, they are translated

into customer-defined ASCII text.

To simplify the external alarms declaration, default values are provided with an alarm

translation table.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

40-1

Page 244: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 244/549

Impacts

Description

Telecom functions are not directly affected, if the detected problem is not disturbing the BTS function.

(#) VSWR and LNA alarms (if equipped), indicates a problem on the antenna output, and degradation may occur.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X# - X#

[9,1...56] EXT-ALARM   Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

40-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 245: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 245/549

Corrective actions

Description

Figure 40-1 EXT-ALARM [9,1...56] : corrective actions

[9,1...56] EXT-ALARM   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

40-3

Page 246: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 246/549

[9,1...56] EXT-ALARM   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

40-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 247: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 247/549

Page 248: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 248/549

Page 249: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 249/549

42   42[9,2] EXT-ALARM (Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Critical (VPMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100/Distributed BTS: There is a AC mains power failure.

9110/9110-E: There is a AC mains power failure detected by SSC.

ImpactsDescription

Telecom functions are not directly affected, as long as the BTS is battery powered. Immediate intervention is necessary, if not the BTS

will go down.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

42-1

Page 250: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 250/549

Page 251: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 251/549

Page 252: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 252/549

Page 253: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 253/549

Corrective actions

Description

Figure 43-1 [9,3] EXT-ALARM: Default corrective actions

[9,3] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

43-3

Page 254: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 254/549

Page 255: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 255/549

44   44[9,4] EXT-ALARM (Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100/Distributed BTS: This is a door/window alarm override by the allowance key.

BTS 9110/9110-E: This is a door alarm for the micro-BTS master, COBOX cover open.

ImpactsDescription

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

44-1

Page 256: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 256/549

Page 257: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 257/549

45   45[9,5] EXT-ALARM (Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Critical (VPMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100/Distributed BTS: Fire alarm by detection of smoke detector inside the cabinet.

BTS 9110/9110-E: This is a PMS alarm for the micro-BTS master, equipment not in vertical

 position.

Impacts

Description

Telecom functions are not directly affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

45-1

Page 258: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 258/549

Corrective actions

Description

Figure 45-1 [9,5] EXT-ALARM: Default Corrective Actions

[9,5] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

45-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 259: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 259/549

46   46[9,6] EXT-ALARM (Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100/Distributed BTS: Water break-in by detection of water detection float switch.

Impacts

Description

Telecom functions are not directly affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

46-1

Page 260: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 260/549

Corrective actions

Description

Figure 46-1 [9,6] EXT-ALARM: Default Corrective Actions

[9,6] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

46-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 261: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 261/549

47   47[9,7] EXT-ALARM (Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100/Distributed BTS: There is a heating/ventilation/cooling system problem. At least one

fan in the heat exchanger unit is faulty.

ImpactsDescription

Telecom functions are not directly affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

47-1

Page 262: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 262/549

Corrective actions

Description

Figure 47-1 [9,7] EXT-ALARM: Default Corrective Actions

[9,7] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

47-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 263: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 263/549

48   48[9,8] EXT-ALARM (Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100/Distributed BTS: The temperature in the equipment rack reached 35° C.

Impacts

Description

Telecom functions are not directly affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

48-1

Page 264: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 264/549

Corrective actions

Description

Figure 48-1 [9,8] EXT-ALARM: Default Corrective Actions

[9,8] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

48-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 265: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 265/549

49   49[9,9] EXT-ALARM (Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: The temperature in the equipment room reached 40 °C.

Impacts

Description

Telecom functions are not directly affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

49-1

Page 266: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 266/549

Corrective actions

Description

Figure 49-1 [9,9] EXT-ALARM: Default corrective actions

[9,9] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

49-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 267: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 267/549

50   50[9,10] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: The antenna mast warning light is faulty.

Impacts

Description

Telecom functions are not directly affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

50-1

Page 268: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 268/549

Corrective actions

Description

Figure 50-1 [9,10] EXT-ALARM: Default corrective actions

[9,10] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

50-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 269: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 269/549

51   51[9,11] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

9100 BTS Indoor: The external battery (if equipped) is deep discharged while supplying the

BTS. The BTS will be switched off after 30 - 60 s.

ImpactsDescription

Telecom functions are not directly affected, as long as the BTS is battery powered, but the BTS will be switched off after 30 - 60 s.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

51-1

Page 270: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 270/549

Corrective actions

Description

Figure 51-1 [9,11] EXT-ALARM: Default corrective actions

[9,11] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

51-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 271: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 271/549

Page 272: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 272/549

Corrective actions

Description

Figure 52-1 [9,12] EXT-ALARM: Default corrective actions

[9,12] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

52-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 273: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 273/549

53   53[9,13] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: The antenna mast warning light is faulty.

BTS 9110/9110-E: This is a PMS alarm for the micro-BTS slave1, equipment not in vertical

 position.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

53-1

Page 274: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 274/549

BTS 9100 corrective actions

Description

Figure 53-1 [9,13] EXT-ALARM: 9100 Default corrective actions

[9,13] EXT-ALARM (Default)   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

53-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 275: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 275/549

54   54[9,14] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: The antenna mast warning light is faulty.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

54-1

Page 276: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 276/549

BTS 9100 corrective actions

Description

Figure 54-1 [9,14] EXT-ALARM: BTS 9100 Default Corrective Actions

[9,14] EXT-ALARM (Default)   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

54-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 277: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 277/549

55   55[9,15] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: This is a door alarm.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

55-1

Page 278: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 278/549

BTS 9100 corrective actions

Description

Figure 55-1 [9,15] EXT-ALARM: BTS 9100 Default Corrective Actions

[9,15] EXT-ALARM (Default)   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

55-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 279: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 279/549

56   56[9,16] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Critical (VPMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: This is a power supply inverter alarm.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

56-1

Page 280: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 280/549

corrective actions

Description

Figure 56-1 [9,16] EXT-ALARM: Default Corrective Actions

[9,16] EXT-ALARM (Default)   corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

56-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 281: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 281/549

57   57[9,17] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: This is a fatal REK alarm on TRX1, MAB detects a VSWR problem.

Impacts

Description

(#) VSWR alarm indicates a problem on the antenna output, and degradation may occur.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X# - X#

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

57-1

Page 282: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 282/549

Corrective actions

Description

Figure 57-1 [9,17] EXT-ALARM: Default corrective actions

[9,17] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

57-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 283: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 283/549

58   58[9,18] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: This is a fatal REK alarm on TRX2, MAB detects a VSWR problem.

Impacts

Description

(#) VSWR alarm indicates a problem on the antenna output, and degradation may occur.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X# - X#

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

58-1

Page 284: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 284/549

Corrective actions

Description

Figure 58-1 [9,18] EXT-ALARM: Default corrective actions

[9,18] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

58-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 285: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 285/549

59   59[9,19] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: This is a fatal REK alarm (if installed) on TRX3, MAB detects a VSWR problem.

Impacts

Description

(#) VSWR alarm indicates a problem on the antenna output, and degradation may occur.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X# - X#

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

59-1

Page 286: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 286/549

Corrective actions

Description

Figure 59-1 [9,19] EXT-ALARM: Default corrective actions

[9,19] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

59-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 287: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 287/549

60   60[9,20] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: This is a fatal REK alarm (if installed) on TRX4, MAB detects a VSWR problem.

BTS 9110/9110-E: This is a door alarm for the micro-BTS slave 2, COBOX cover open.

ImpactsDescription

(#) VSWR alarm indicates a problem on the antenna output, and degradation may occur.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X# - X#

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

60-1

Page 288: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 288/549

BTS 9100 corrective actions

Description

Figure 60-1 [9,20] EXT-ALARM: BTS 9100 Default corrective actions

[9,20] EXT-ALARM (Default)   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

60-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 289: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 289/549

61   61[9,21] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: This is a fatal REK alarm (if installed) on TRX5, MAB detects a VSWR problem.

9110/9110-E: This is a PMS alarm for the micro-BTS slave2, equipment not in vertical

 position.

Impacts

Description

(#) VSWR alarm indicates a problem on the antenna output, and degradation may occur.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X# - X#

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

61-1

Page 290: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 290/549

BTS 9100 corrective actions

Description

Figure 61-1 [9,21] EXT-ALARM: BTS 9100 Default corrective actions

[9,21] EXT-ALARM (Default)   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

61-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 291: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 291/549

62   62[9,22] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: This is a fatal REK alarm (if installed) on TRX6, MAB detects a VSWR problem.

Impacts

Description

(#) VSWR alarm indicates a problem on the antenna output, and degradation may occur.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X# - X#

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

62-1

Page 292: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 292/549

Corrective actions

Description

Figure 62-1 [9,22] EXT-ALARM: Default corrective actions

[9,22] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

62-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 293: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 293/549

63   63[9,23] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100 : This is a REK alarm (if installed) on LNA, at least one receive path has a LNA

 problem.

ImpactsDescription

(#) PDU/LNA alarm indicates a problem on the antenna amplifier output, and degradation may occur.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X# - X#

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

63-1

Page 294: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 294/549

BTS 9100 corrective actions

Description

Figure 63-1 [9,23] EXT-ALARM: Default corrective actions

[9,23] EXT-ALARM (Default)   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

63-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 295: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 295/549

64   64[9,24] EXT-ALARM

(Default)

Definition

Description

specific Problems   EXT-ALARM

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA)

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9100: There is a heating/ventilation/cooling system problem. At least one fan in the heat

exchanger unit is faulty.

ImpactsDescription

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

64-1

Page 296: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 296/549

Corrective actions

Description

Figure 64-1 [9,24] EXT-ALARM: 9100 Default Corrective Actions

[9,24] EXT-ALARM (Default)   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

64-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 297: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 297/549

65   65[9,25] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

65-1

Page 298: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 298/549

Page 299: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 299/549

Page 300: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 300/549

[9,26] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

66-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 301: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 301/549

67   67[9,27] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

67-1

Page 302: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 302/549

[9,27] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

67-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 303: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 303/549

68   68[9,28] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9110-E: This is a door alarm for the micro-BTS slave 11, COBOX cover open.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

68-1

Page 304: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 304/549

[9,28] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

68-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 305: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 305/549

69   69[9,29] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

9110-E: This is a PMS alarm for the micro-BTS slave11, equipment not in vertical position.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

69-1

Page 306: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 306/549

[9,29] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

69-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 307: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 307/549

70   70[9,30] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

70-1

Page 308: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 308/549

[9,30] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

70-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 309: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 309/549

71   71[9,31] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

71-1

Page 310: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 310/549

[9,31] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

71-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 311: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 311/549

72   72[9,32] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

72-1

Page 312: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 312/549

[9,32] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

72-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 313: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 313/549

73   73[9,33] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

73-1

Page 314: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 314/549

[9,33] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

73-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 315: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 315/549

74   74[9,34] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

74-1

Page 316: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 316/549

[9,34] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

74-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 317: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 317/549

75   75[9,35] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

75-1

Page 318: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 318/549

[9,35] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

75-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 319: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 319/549

76   76[9,36] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9110-E: This is a door alarm for the micro-BTS slave 12, COBOX cover open.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

76-1

Page 320: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 320/549

[9,36] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

76-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 321: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 321/549

77   77[9,37] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

9110-E: This is a PMS alarm for the micro-BTS slave12, equipment not in vertical position.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

77-1

Page 322: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 322/549

Page 323: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 323/549

78   78[9,38] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

78-1

Page 324: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 324/549

[9,38] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

78-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 325: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 325/549

79   79[9,39] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

79-1

Page 326: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 326/549

[9,39] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

79-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 327: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 327/549

80   80[9,40] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

80-1

Page 328: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 328/549

[9,40] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

80-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 329: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 329/549

81   81[9,41] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

81-1

Page 330: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 330/549

[9,41] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

81-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 331: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 331/549

82   82[9,42] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

82-1

Page 332: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 332/549

Page 333: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 333/549

83   83[9,43] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence..

Indeterminate - event, without End alert..

Warning - out of commercial use; complete Begin/End alert sequence..

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

83-1

Page 334: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 334/549

[9,43] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

83-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 335: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 335/549

84   84[9,44] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9110-E: This is a door alarm for the micro-BTS slave 21, COBOX cover open.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

84-1

Page 336: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 336/549

[9,44] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

84-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 337: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 337/549

85   85[9,45] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

9110-E: This is a PMS alarm for the micro-BTS slave21, equipment not in vertical position.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

85-1

Page 338: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 338/549

[9,45] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

85-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 339: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 339/549

86   86[9,46] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

86-1

Page 340: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 340/549

[9,46] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

86-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 341: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 341/549

87   87[9,47] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

87-1

Page 342: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 342/549

[9,47] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

87-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 343: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 343/549

Page 344: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 344/549

[9,48] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

88-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 345: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 345/549

89   89[9,49] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

89-1

Page 346: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 346/549

[9,49] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

89-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 347: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 347/549

Page 348: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 348/549

[9,50] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

90-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 349: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 349/549

91   91[9,51] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

91-1

Page 350: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 350/549

[9,51] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

91-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 351: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 351/549

92   92[9,52] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

BTS 9110-E: This is a door alarm for the micro-BTS slave 22, COBOX cover open.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

92-1

Page 352: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 352/549

Page 353: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 353/549

93   93[9,53] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   To simplify the external alarms declaration, default values are provided with an alarm

translation table.

9110-E: This is a PMS alarm for the micro-BTS slave22, equipment not in vertical position.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

93-1

Page 354: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 354/549

[9,53] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

93-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 355: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 355/549

94   94[9,54] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

94-1

Page 356: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 356/549

[9,54] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

94-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 357: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 357/549

95   95[9,55] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

95-1

Page 358: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 358/549

[9,55] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

95-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 359: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 359/549

96   96[9,56] EXT-ALARM for

9110-E (Default)

Definition

Description

Specific Problems   EXT-ALARM

Event Type   Equipment

Probable Cause   Indeterminate

Perceived Severity   Minor (DMA) - in commercial use; complete Begin/End alert sequence.

Indeterminate - event, without End alert.

Warning - out of commercial use; complete Begin/End alert sequence.

Alarm Description   BTS 9110-E: Available and not used.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

96-1

Page 360: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 360/549

[9,56] EXT-ALARM for 9110-E (Default)   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

96-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 361: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 361/549

Part VIII: Class 10: RX-TX alarms

Overview

Purpose

This section defines the alarms for the Class 10: RX-TX alarms.

Contents

Chapter 97, [10,1] RSL-LINK 97-1

Chapter 98, [10,3] RX-CABLE 98-1

Chapter 99, [10,10] TRE-VSWR 99-1

Chapter 100, [10,11] ANTENNA-VSWR-WARNING 100-1

Chapter 101, [10,12] ANTENNA-VSWR-URGENT 101-1

Chapter 102, [10,21] MODULE-FRAME-SIGNAL 102-1

Chapter 103, [10,22] MODULE-CLOCK-SIGNAL 103-1

Chapter 104, [10,39] MC-RH-NOT-REACHABLE 104-1

Chapter 105, [10,51] MODULE-NOT-PRESENT 105-1

Chapter 106, [10,234] IOM-DISCONNECTION 106-1

Chapter 107, [10,237] HW-DEGRADED 107-1

Chapter 108, [10,239] HW-FAILURE 108-1

Chapter 109, [10,248] RESTART 109-1

Chapter 110, [10, 249] SMART-RESTART 110-1

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

VIII-1

Page 362: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 362/549

Class 10: RX-TX alarms   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

VIII-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 363: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 363/549

97   97[10,1] RSL-LINK

Definition

Description

specific Problems   RSL-LINK 

event Type   Communication

probable Cause   Communications Protocol Error 

perceived Severity   Warning (MI)

Alarm Description   The Lapd channel RSL between BSC and BTS TRE is faulty.

This can be due to transmission problem or to BSC TCU unavailability (faulty or operator 

disabled). In this situation, the TRE performs an auto-restart after having run a timer 

(BCCH_CUT_Timer).

ImpactsDescription

The concerned TRE does :not carry traffic as long as the Lapd RSL is not reestablished.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X X X

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

97-1

Page 364: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 364/549

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,1] RSL-LINK    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

97-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 365: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 365/549

Figure 97-1 RSL-LINK: BTS 9100 corrective actions

[10,1] RSL-LINK    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

97-3

Page 366: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 366/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,1] RSL-LINK    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

97-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 367: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 367/549

Figure 97-2 RSL-LINK: 9110/9110-E Micro BTS corrective actions

[10,1] RSL-LINK    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

97-5

Page 368: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 368/549

[10,1] RSL-LINK    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

97-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 369: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 369/549

98   98[10,3] RX-CABLE

[10,3] RX-CABLE (TRE)

Definition

Description

specific Problems   RX-CABLE

event Type   Equipment

probable Cause   Configuration Or Customization Error 

perceived Severity   Major (PMA)

Alarm Description   An error has been detected in the cabling between a TRE and an ANX.

Alarm Number 1: The DC signal on RX0 has been lost.

2: The DC signal on RX1 has been lost.

5: The DC signal on RX0 & RX1 has been lost, or has been lost on RX0 only, when antenna

diversity is installed.

Impacts

Description

The cell is lost.

Impact BSS Cell(s) Signaling Calls

Loss - X X X

Degradation X - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

98-1

Page 370: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 370/549

Corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,3] RX-CABLE [10,3] RX-CABLE (TRE)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

98-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 371: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 371/549

Figure 98-1 RX-CABLE (TRE):corrective actions

[10,3] RX-CABLE [10,3] RX-CABLE (TRE)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

98-3

Page 372: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 372/549

[10,3] RX-CABLE (RA)

Definition

Description

specific Problems   RX-CABLE

event Type   Equipment

probable Cause   Configuration Or Customization Error 

perceived Severity   Nbr 3: Major (PMA)

 Nbr 4: Minor (DMA)

Alarm Description   An error has been detected in the cabling between a TRE and an ANX/ANC.

Alarm Number 3: Several TREs connected to the same ANX/ANC have detected a cabling error (cabling

 between TRE and ANX/ANC) on  both RX paths, or on RX0 path only, when antenna diversity

is installed.

4: Several TREs connected to the same ANX/ANC have detected a cabling error (cabling

 between TRE and ANX/ANC) on  one RX path only, when antenna diversity is installed.

Impacts

Description

The cell is lost.Impact BSS Cell(s) Signaling Calls

Loss - X X X

Degradation X - - -

[10,3] RX-CABLE [10,3] RX-CABLE (RA)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

98-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 373: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 373/549

Corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,3] RX-CABLE [10,3] RX-CABLE (RA)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

98-5

Page 374: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 374/549

Figure 98-2 RX-CABLE (RA): corrective actions

[10,3] RX-CABLE [10,3] RX-CABLE (RA)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

98-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 375: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 375/549

99   99[10,10] TRE-VSWR

Definition

Description

specific Problems   TRE-VSWR 

event Type   Equipment

probable Cause   Transmitter Failure

perceived Severity   Major (PMA)

Alarm Description   A fault has been detected by the VSWR supervision on the TRE output (fault on a TX cable

connected to ANX/ANY or to an antenna if Distributed BTS) during initialization or 

operational states. The power amplifier of the TRE automatically switches itself off, in order to

avoid any HW damage.

Impacts

Description

The TRE is no longer usable. The associated eight channels are lost. Independent of frequency hopping or not, the BSC reduces the

number of channels supported by the cell.

If the TRE supporting the BCCH is not concerned, the cell is degraded, calls are lost. (#).

If the TRE supporting the BCCH is concerned and there is BCCH redundancy, recovery mechanisms regain the cell's functionality. (*).

If the TRE supporting the BCCH is concerned and there is no BCCH redundancy, the complete cell is lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X X X#*

Degradation X #* - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

99-1

Page 376: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 376/549

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,10] TRE-VSWR   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

99-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 377: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 377/549

Figure 99-1 TRE-VSWR: BTS 9100 corrective actions

[10,10] TRE-VSWR   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

99-3

Page 378: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 378/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,10] TRE-VSWR   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

99-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 379: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 379/549

Figure 99-2 TRE-VSWR: BTS 9110/9110-E corrective actions

[10,10] TRE-VSWR   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

99-5

Page 380: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 380/549

Distributed BTS Corrective Actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,10] TRE-VSWR   Distributed BTS Corrective Actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

99-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 381: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 381/549

Figure 99-3 TRE-VSWR: Distributed BTS Corrective Actions

[10,10] TRE-VSWR   Distributed BTS Corrective Actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

99-7

Page 382: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 382/549

Page 383: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 383/549

100   100[10,11] ANTENNA-VSWR-

WARNING

Definition

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

Note: Required tools and materials

•   Antenna Test Tools

•   Antenna Dummy Load

specific Problems   ANTENNA-VSWR-WARNING

event Type   Equipment

probable Cause   Transmitter Failure

perceived Severity   Minor (DMA), Warning (MI)

Alarm Description   A fault has been detected concerning VSWR antenna supervision.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

100-1

Page 384: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 384/549

Alarm Number 1 (only for 9100 BTS): The LOW (first) threshold of antenna 1 VSWR has been exceeded.

2 (only for 9100 BTS): The LOW (first) threshold of antenna 2 VSWR has been exceeded.

3 (only for 9100 BTS): The LOW (first) thresholds on both antenna 1 and 2 have been

exceeded.

4 (only for 9110-E BTS): VSWR 1 alarm for Master.

5 (only for 9110-E BTS): VSWR 2 alarm for Master.

6 (only for 9110-E BTS): VSWR 1 alarm for Slave 1.

7 (only for 9110-E BTS): VSWR 2 alarm for Slave 1.

8 (only for 9110-E BTS): VSWR 1 alarm for Slave 2.

9 (only for 9110-E BTS): VSWR 2 alarm for Slave 2.

10 (only for 9110-E BTS): VSWR 1 alarm for Slave 11.

11 (only for 9110-E BTS): VSWR 2 alarm for Slave 11.

12 (only for 9110-E BTS): VSWR 1 alarm for Slave 12.

13 (only for 9110-E BTS): VSWR 2 alarm for Slave 12.

14 (only for 9110-E BTS): VSWR 1 alarm for Slave 21.

15 (only for 9110-E BTS): VSWR 2 alarm for Slave 21.16 (only for 9110-E BTS): VSWR 1 alarm for Slave 22.

17 (only for 9110-E BTS): VSWR 2 alarm for Slave 22.

18 (only for distributed BTS): MC-RRH VSWR Warning

Impacts

Description

Impact BSS Cell(s) Signaling Calls

Transmission quality is degraded

Loss - - - -

Degradation - - X X

[10,11] ANTENNA-VSWR-WARNING   Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

100-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 385: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 385/549

BTS 9100 corrective actions

Description

Figure 100-1 ANTENNA-VSWR-WARNING: Corrective Actions for 9100 BTS

[10,11] ANTENNA-VSWR-WARNING   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

100-3

Page 386: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 386/549

BTS 9110-E corrective actions

Description

Figure 100-2 ANTENNA-VSWR-WARNING: Corrective Actions for 9110-E BTS

[10,11] ANTENNA-VSWR-WARNING   BTS 9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

100-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 387: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 387/549

Distributed BTS corrective actions

Description

Figure 100-3 ANTENNA-VSWR-WARNING: Corrective Actions for Distributed BTS

[10,11] ANTENNA-VSWR-WARNING   Distributed BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

100-5

Page 388: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 388/549

[10,11] ANTENNA-VSWR-WARNING   Distributed BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

100-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 389: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 389/549

101   101[10,12] ANTENNA-VSWR-

URGENT

Definition

Description

specific Problems   ANTENNA-VSWR-URGENT

event Type   Equipment

probable Cause   Transmitter Failure

perceived Severity   Major (PMA)

Alarm Description   A fault has been detected concerning VSWR antenna supervision.

Alarm Number 1: The High (second) threshold of antenna 1 VSWR has been exceeded.

2: The High (second) threshold of antenna 2 VSWR has been exceeded.

3: The High (second) thresholds on both antenna 1 and 2 have been exceeded.

4: MC-RRH VSWR Urgent

Impacts

Description

The cell is lost.

Impact BSS Cell(s) Signaling Calls

Loss - X X X

Degradation X - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

101-1

Page 390: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 390/549

Corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

Note: Required tools and materials

•   Antenna Test Tools

•   Antenna Dummy Load

[10,12] ANTENNA-VSWR-URGENT    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

101-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 391: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 391/549

Figure 101-1 ANTENNA-VSWR-URGENT: corrective actions

[10,12] ANTENNA-VSWR-URGENT    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

101-3

Page 392: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 392/549

Description (2)

Figure 101-2 ANTENNA-VSWR-URGENT: Corrective Actions, continued

[10,12] ANTENNA-VSWR-URGENT    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

101-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 393: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 393/549

Description (3)

Note: Reduced TX Power

If the transmit power was reduced, set transmit power settings back to previous values

when the problem is solved.

Figure 101-3 ANTENNA-VSWR-URGENT: Corrective Actions, continued

[10,12] ANTENNA-VSWR-URGENT    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

101-5

Page 394: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 394/549

Distributed BTS corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

Note: Required tools and materials

•   Antenna Test Tools

•   Antenna Dummy Load

[10,12] ANTENNA-VSWR-URGENT    Distributed BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

101-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 395: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 395/549

Page 396: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 396/549

[10,12] ANTENNA-VSWR-URGENT    Distributed BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

101-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 397: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 397/549

102   102[10,21] MODULE-FRAME-

SIGNAL

[10,21] MODULE-FRAME-SIGNAL (TRE)

Definition

Description

specific Problems   MODULE-CLOCK-SIGNAL

event Type   Equipment

probable Cause   Loss Of Signal

perceived Severity   Minor (DMA)

Alarm Description   A fault is detected on a multiframe clock signal from SUM.

Impacts

Description

Transmission quality is degraded.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - X X

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

102-1

Page 398: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 398/549

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,21] MODULE-FRAME-SIGNAL[10,21] MODULE-FRAME-SIGNAL (TRE)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

102-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 399: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 399/549

Figure 102-1 MODULE-FRAME-SIGNAL (TRE): BTS 9100 corrective actions

[10,21] MODULE-FRAME-SIGNAL[10,21] MODULE-FRAME-SIGNAL (TRE)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

102-3

Page 400: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 400/549

Page 401: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 401/549

Figure 102-2 MODULE-FRAME-SIGNAL (TRE): BTS 9110/9110-E corrective actions

[10,21] MODULE-FRAME-SIGNAL[10,21] MODULE-FRAME-SIGNAL (TRE)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

102-5

Page 402: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 402/549

Page 403: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 403/549

Figure 102-3 MODULE-FRAME-SIGNAL (RA): corrective actions

[10,21] MODULE-FRAME-SIGNAL[10,21] MODULE-FRAME-SIGNAL (RA)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

102-7

Page 404: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 404/549

[10,21] MODULE-FRAME-SIGNAL   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

102-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 405: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 405/549

103   103[10,22] MODULE-CLOCK-

SIGNAL

[10,22] MODULE-CLOCK-SIGNAL (TRE)

Definition

Description

specific Problems   MODULE-CLOCK-SIGNAL

event Type   Equipment

probable Cause   Loss Of Signal

perceived Severity   Minor (DMA)

Alarm Description   The input clock signal doesn't allow the TRE module to work.

Alarm Number 1: Synchronization in clocks and FN has failed during initialization state.

2: CLKI master clock failure has been detected in the operational state.

Impacts

Description

The TRE is no longer usable. The associated eight channels are lost. Independent of frequency hopping or not, the BSC reduces the

number of channels supported by the cell.

If the TRE supporting the BCCH is not concerned, the cell is degraded, calls are lost. (#).

If the TRE supporting the BCCH is concerned and there is BCCH redundancy, recovery mechanisms regain the cell's functionality. (*).

If the TRE supporting the BCCH is concerned and there is no BCCH redundancy, the complete cell is lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X X X#*

Degradation X #* - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

103-1

Page 406: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 406/549

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,22] MODULE-CLOCK-SIGNAL[10,22] MODULE-CLOCK-SIGNAL (TRE)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

103-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 407: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 407/549

Figure 103-1 MODULE-CLOCK-SIGNAL (TRE): BTS 9100 corrective actions

[10,22] MODULE-CLOCK-SIGNAL[10,22] MODULE-CLOCK-SIGNAL (TRE)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

103-3

Page 408: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 408/549

Page 409: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 409/549

Figure 103-2 MODULE-CLOCK-SIGNAL (TRE): BTS 9110/9110-E corrective actions

[10,22] MODULE-CLOCK-SIGNAL[10,22] MODULE-CLOCK-SIGNAL (TRE)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

103-5

Page 410: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 410/549

[10,22] MODULE-CLOCK-SIGNAL (RA)

Definition

Description

specific Problems   MODULE-CLOCK-SIGNAL

event Type   Equipment

probable Cause   Loss Of Signal

perceived Severity   Minor (DMA)

Alarm Description   The input clock signal on ANX is faulty.

Alarm Number 1: Synchronization in clocks and frame numbers has failed during initialization state.

2: CLKI master clock failure has been detected in the operational state.

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

[10,22] MODULE-CLOCK-SIGNAL[10,22] MODULE-CLOCK-SIGNAL (RA)

[10,234] IOM-DISCONNECTION (TRE)

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

103-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 411: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 411/549

Corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,22] MODULE-CLOCK-SIGNAL[10,22] MODULE-CLOCK-SIGNAL (RA)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

103-7

Page 412: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 412/549

Figure 103-3 MODULE-CLOCK-SIGNAL: corrective actions

[10,22] MODULE-CLOCK-SIGNAL[10,22] MODULE-CLOCK-SIGNAL (RA)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

103-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 413: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 413/549

104   104[10,39] MC-RH-NOT-

REACHABLE

Definition

Description

specific Problems   MODULE-NOT-PRESENT

event Type   Equipment

probable Cause   Replaceable Unit Problem

perceived Severity   Major (PMA)

Alarm Description   Loss of non-redundant connection from a MC-module to SUM or double link failure. In these

cases a link failure leads to a module failure.

Alarm Number 17: Loss of non-redundant connection from a MC-module to SUM or double link failure. In

these cases a link failure leads to a module failure.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

104-1

Page 414: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 414/549

Corrective actions

Description

Figure 104-1 MC-RH-NOT-REACHABLE: corrective actions

[10,39] MC-RH-NOT-REACHABLE    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

104-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 415: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 415/549

105   105[10,51] MODULE-NOT-

PRESENT

[10,51] MODULE-NOT-PRESENT (TRE)

Description

specific Problems   MODULE-NOT-PRESENT

event Type   Equipment

probable Cause   Replaceable Unit Problem

perceived Severity   Major (PMA)

Alarm Description   A TRE module was not initially present, or has recently been extracted.

Alarm Number 1: The BCB detects the extraction of the module.

2: There is no associated module for this SBL.

Impacts

Description

The TRE is no longer usable. The associated eight channels are lost. Independent of frequency hopping or not, the BSC reduces the

number of channels supported by the cell.

If the TRE supporting the BCCH is not concerned, the cell is degraded, calls are lost. (#).

If the TRE supporting the BCCH is concerned and there is BCCH redundancy, recovery mechanisms regain the cell's functionality, calls

are lost. (*)

If the TRE supporting the BCCH is concerned and there is no BCCH redundancy, the complete cell is lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X X X#*

Degradation X #* - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

105-1

Page 416: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 416/549

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,51] MODULE-NOT-PRESENT    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

105-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 417: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 417/549

Figure 105-1 MODULE-NOT-PRESENT (TRE): BTS 9100 corrective actions

[10,51] MODULE-NOT-PRESENT    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

105-3

Page 418: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 418/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,51] MODULE-NOT-PRESENT    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

105-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 419: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 419/549

Figure 105-2 MODULE-NOT-PRESENT (TRE): BTS 9110/9110-E corrective actions

[10,51] MODULE-NOT-PRESENT    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

105-5

Page 420: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 420/549

[10,51] MODULE-NOT-PRESENT (RA)

Description

specific Problems   MODULE-NOT-PRESENT

event Type   Equipment

probable Cause   Replaceable Unit Problem

perceived Severity   Major (PMA)

Alarm Description   An ANC or ANX is not present.

Alarm Number   The BCB detects the absence of the ANX/ANC module and there is no other ANX/ANC

operational in the same sector.

Impacts

Description

The sector is lost.

Impact BSS Cell(s) Signaling Calls

Loss - X X X

Degradation X - - -

Corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,51] MODULE-NOT-PRESENT    [10,51] MODULE-NOT-PRESENT (RA)

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

105-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 421: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 421/549

Figure 105-3 MODULE-NOT-PRESENT (RA): corrective actions

[10,51] MODULE-NOT-PRESENT    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

105-7

Page 422: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 422/549

[10,51] MODULE-NOT-PRESENT    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

105-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 423: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 423/549

106   106[10,234] IOM-

DISCONNECTION

[10,234] IOM-DISCONNECTION (TRE)

Description

specific Problems   IOM-DISCONNECTION

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Minor (DMA)

Alarm Description   The IOM connection on BSII is faulty.

Impacts

Description

Telecom functions are not affected, as long as no commands on the Managed Objects (SBLs) TRE or RA are executed.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

106-1

Page 424: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 424/549

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,234] IOM-DISCONNECTION    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

106-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 425: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 425/549

Figure 106-1 IOM-DISCONNECTION (TRE): BTS 9100 corrective actions

[10,234] IOM-DISCONNECTION    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

106-3

Page 426: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 426/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,234] IOM-DISCONNECTION    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

106-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 427: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 427/549

Figure 106-2 IOM-DISCONNECTION (TRE): BTS 9110/9110-E corrective actions

[10,234] IOM-DISCONNECTION    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

106-5

Page 428: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 428/549

Distributed BTS corrective actions

Description

Figure 106-3 IOM-DISCONNECTION (TRE): Distributed BTS corrective actions

[10,234] IOM-DISCONNECTION    Distributed BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

106-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 429: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 429/549

[10,234] IOM-DISCONNECTION (RA)

Description

specific Problems   IOM-DISCONNECTION

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Minor (DMA)

Alarm Description   The IOM connection on BSII is faulty.

Impacts

Description

Telecom functions are not affected, as long as no commands on the Managed Objects (SBLs) TRE or RA are executed.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - -

Corrective actions

DescriptionNote: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,234] IOM-DISCONNECTION    [10,234] IOM-DISCONNECTION (RA)

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

106-7

Page 430: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 430/549

Figure 106-4 IOM-DISCONNECTION (RA): corrective actions

[10,234] IOM-DISCONNECTION    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

106-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 431: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 431/549

107   107[10,237] HW-DEGRADED

[10,237] HW-DEGRADED (TRE)

Definition

Description

specific Problems   HW-DEGRADED

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Minor (DMA), Warning (MI)

Alarm Description   Nbr 3: The BCB link to the module is faulty.

 Nbr 12: This is an output power drop error.

 Nbr 13: Hardware failure on unused part of twin (The twin in its current configuration operates

correctly. A problem will only occur when the configuration will be changed.)

 Nbr 15: MC-RRH out of sync

 Nbr 16: Bias adjust non urgent PA1.

 Nbr 18: Fan 1 of MC-TRDU has failed. Note: TRE SBL goes to FIT.

 Nbr 19: Fan 2 of MC-TRDU has failed. Note: TRE SBL goes to FIT.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

107-1

Page 432: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 432/549

Impacts

Description

The antenna diversity is lost and the quality of reception is degraded.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - X

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (TRE)

Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

107-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 433: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 433/549

Figure 107-1 HW-DEGRADED (TRE): BTS 9100 corrective actions

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (TRE)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

107-3

Page 434: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 434/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (TRE)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

107-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 435: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 435/549

Figure 107-2 HW-DEGRADED (TRE): BTS 9110/9110-E corrective actions

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (TRE)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

107-5

Page 436: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 436/549

Page 437: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 437/549

[10,237] HW-DEGRADED (RA)

Definition

Description

specific Problems   HW-DEGRADED

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Minor (DMA), Warning (MI)

Alarm Description   This is a HW failure, a local recovery action has failed.

Alarm Number 3: The BCB link to the module is faulty. The information provided by the BCB terminal of the

module is inconsistent. The communication on the BCB is corrupted by any module.

4: The antenna VSWR circuitry is defective.

5: A non-fatal fault has been detected on LNA 1 with 6 dB less gain on RX1.

6: A non-fatal fault has been detected on LNA 2 with 6 dB less gain on RX2.

7: A fatal fault has been detected on LNA 1: RX1 is lost. Consequently, antenna diversity is lost.

8: A fatal fault has been detected on LNA 2: RX2 is lost. Consequently, antenna diversity is lost,

if used.

9: A HW failure is detected by auto-test, either in initialization state or in fault localization state,

or by selftest in initialization state.

11: The module is in operational state but faulty, the Local Recovery Action failed.

13: The AGC cannot reach the LNA module. (This alarm occurs only for the AGC module.)

14: RX LNA failure

Impacts

Description

Alarm Numbers 3, 4, 5, 6, 9, 11: There is no disturbance of the telecom application.

Alarm Numbers 7, 8: The antenna diversity is lost and the quality of reception is degraded.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - - - X

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (RA)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

107-7

Page 438: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 438/549

Page 439: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 439/549

Figure 107-4 HW-DEGRADED (RA): BTS 9100, Alarm Number 3 corrective actions

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (RA)

BTS 9100, Alarm Number 3 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

107-9

Page 440: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 440/549

BTS 9100, Alarm Number 4...11, 13 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (RA)

BTS 9100, Alarm Number 4...11, 13 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

107-10   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 441: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 441/549

Page 442: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 442/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (RA)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

107-12   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 443: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 443/549

Figure 107-6 HW-DEGRADED (RA): BTS 9100, Alarm Number 3 corrective actions

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (RA)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

107-13

Page 444: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 444/549

Distributed BTS Alarm Number 14 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (RA)

Distributed BTS Alarm Number 14 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

107-14   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 445: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 445/549

Figure 107-7 HW-DEGRADED (RA): Distributed BTS, Alarm Number 14 correctiveactions

[10,237] HW-DEGRADED[10,237] HW-DEGRADED (RA)

Distributed BTS Alarm Number 14 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

107-15

Page 446: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 446/549

[10,237] HW-DEGRADED   Distributed BTS Alarm Number 14 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

107-16   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 447: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 447/549

108   108[10,239] HW-FAILURE

[10,239] HW-FAILURE (TRE)

Definition

Description

specific Problems   HW-FAILURE

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA), Minor (DMA)

Alarm Description Major (PMA): This is a HW failure, a local recovery action has failed.

Minor (DMA): The local recovery is successful.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

108-1

Page 448: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 448/549

Alarm Number 1: A HW failure is detected by the auto-test, either in initialization state or in fault localization

state, or by selftest in initialization state (failures not covered by other numbers).

2: The DC/DC converter has failed.

3: A fatal error has been reported by a layer 1 DSP concerning the radio.

4: A fault has been detected at the Entity Control Parallel Link (ECPL) interface management.

5: One DSP has reported a fatal error in its internal processing.

6: At least one DSP has not answered to the SCP polling.

7: A fatal error has been reported by a layer 1 DSP or the MBED on a serial internal interface.

8: The FN_SUP timer (FN supervision) elapsed: FCLK interrupt is missing.

9: The internal FNs from layer 1 are not consistent.

11: The module was not in an operational state (no more information is available). The OMU

has performed a Local Recovery Action.

12: The module has no input power.

13: The front panel power switch is set off (Power Off) for the concerned module.

14: Unknown cause: alarm indicates that more detailed alarms were reported before and are

available at OMC-R.

15: The TRE reported to OMU BSII a failure alarm. The OMU has then performed on TRE a

Local Recovery Action which has failed.

16: TRE internal PLL not locked.

18: Bias adjust urgent PA1.

Impacts

Description

The TRE is no longer usable. The associated eight channels are lost. Independent of frequency hopping or not, the BSC reduces thenumber of channels supported by the cell.

If the TRE supporting the BCCH is not concerned, the cell is degraded, calls are lost. (#).

If the TRE supporting the BCCH is concerned and there is BCCH redundancy, recovery mechanisms regain the cell's functionality, calls

are lost. (*)

If the TRE supporting the BCCH is concerned and there is no BCCH redundancy, the complete cell is lost. (X).

Impact BSS Cell(s) Signaling Calls

Loss - X X X#*

Degradation X #* - -

[10,239] HW-FAILURE [10,239] HW-FAILURE (TRE)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

108-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 449: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 449/549

BTS 9100, Alarm Number 1...11, 15, 16 and 18 correctiveactions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,239] HW-FAILURE [10,239] HW-FAILURE (TRE)

BTS 9100, Alarm Number 1...11, 15, 16 and 18 correctiveactions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

108-3

Page 450: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 450/549

Additionally for alarm number 3: in case the alarm is reported by several TREs and the

additional info contains either DF 3B 03 20 1C 19 DF 3D 14 01 15 00 00 00 00 00 00 00

00 00 00 01 00 00 00 00 00 00 00 or DF 3B 03 20 1C 19 DF 3D 22 01 15 00 00 00 00 00

Figure 108-1 HW-FAILURE (TRE): 9100 BTS, Alarm Number 1...11, 15, 16 and 18corrective actions

[10,239] HW-FAILURE [10,239] HW-FAILURE (TRE)

BTS 9100, Alarm Number 1...11, 15, 16 and 18 correctiveactions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

108-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 451: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 451/549

00 00 00 00 00 00 00 xx xx xx xx 00 01 00 00 00 00 00 00 00 00 00 00 xx xx xx xx

(whatever xx is) and thus indicating a “L1 status: LD_13MHz, no lock detection for 13

MHz synthesiser (ENCT)” replace the SUMx board as this one causes the alarms.

BTS 9100, Alarm Number 12 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,239] HW-FAILURE [10,239] HW-FAILURE (TRE)

BTS 9100, Alarm Number 1...11, 15, 16 and 18 correctiveactions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

108-5

Page 452: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 452/549

Figure 108-2 HW-FAILURE (TRE): 9100 BTS, Alarm Number 12 corrective actions

[10,239] HW-FAILURE [10,239] HW-FAILURE (TRE)

BTS 9100, Alarm Number 12 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

108-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 453: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 453/549

BTS 9100, Alarm Number 13 corrective actions

Description

Figure 108-3 HW-FAILURE (TRE): 9100 BTS, Alarm Number 13 corrective actions

[10,239] HW-FAILURE [10,239] HW-FAILURE (TRE)

BTS 9100, Alarm Number 13 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

108-7

Page 454: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 454/549

Micro BTS 9110/9110-E corrective actions

Description

Figure 108-4 HW-FAILURE (TRE): 9110 Micro BTS/9110-E Micro BTS corrective

actions

[10,239] HW-FAILURE [10,239] HW-FAILURE (TRE)

Micro BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

108-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 455: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 455/549

[10,239] HW-FAILURE (RA)

Definition

Description

specific Problems   HW-FAILURE

event Type   Equipment

probable Cause   Equipment Malfunction

perceived Severity   Major (PMA)

Alarm Description   This is a HW failure, a local recovery action has failed.

Alarm Number 2: The DC/DC converter of the module failed.

10: A fatal fault has been detected on both LNA 1 and LNA 2: RX1 and RX2 are lost. Or fault

detected on LNA1 only if no antenna diversity configuration or on LNA2 only for 9110 Micro

BTS in no antenna diversity configuration and MAN is configured with two sectors.

12: The module has no input power.

14: Unknown cause, alarm indicates that more detailed alarms were reported before and are

available at OMC-R.

Impacts

Description

The sector is lost.

Impact BSS Cell(s) Signaling Calls

Loss - X X X

Degradation X - - -

[10,239] HW-FAILURE [10,239] HW-FAILURE (RA)

Definition

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

108-9

Page 456: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 456/549

BTS 9100, Alarm Number 2 and 12 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,239] HW-FAILURE [10,239] HW-FAILURE (RA)

BTS 9100, Alarm Number 2 and 12 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

108-10   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 457: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 457/549

Figure 108-5 HW-FAILURE (RA): BTS 9100, Alarm Number 2 and 12 CorrectiveActions

[10,239] HW-FAILURE [10,239] HW-FAILURE (RA)

BTS 9100, Alarm Number 2 and 12 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

108-11

Page 458: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 458/549

BTS 9100, Alarm Number 10 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,239] HW-FAILURE [10,239] HW-FAILURE (RA)

BTS 9100, Alarm Number 10 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

108-12   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 459: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 459/549

Figure 108-6 HW-FAILURE (RA): BTS 9100, Alarm Number 10 corrective actions

[10,239] HW-FAILURE [10,239] HW-FAILURE (RA)

BTS 9100, Alarm Number 10 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

108-13

Page 460: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 460/549

BTS 9100, Alarm Number 14 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,239] HW-FAILURE [10,239] HW-FAILURE (RA)

BTS 9100, Alarm Number 14 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

108-14   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 461: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 461/549

Figure 108-7 HW-FAILURE (RA): BTS 9100, Alarm Number 14 corrective actions

[10,239] HW-FAILURE [10,239] HW-FAILURE (RA)

BTS 9100, Alarm Number 14 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

108-15

Page 462: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 462/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,239] HW-FAILURE [10,239] HW-FAILURE (RA)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

108-16   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 463: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 463/549

Figure 108-8 HW-FAILURE (RA): BTS 9110/9110-E corrective actions

[10,239] HW-FAILURE [10,239] HW-FAILURE (RA)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

108-17

Page 464: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 464/549

[10,239] HW-FAILURE    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

108-18   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 465: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 465/549

109   109[10,248] RESTART

[10,248] RESTART (TRE)

Definition

Description

specific Problems   RESTART

event Type   Processing Error 

probable Cause   Application Subsystem Failure

perceived Severity   Warning (MI)

Alarm Description   The TRE has (auto)restarted successfully.

Alarm Number 3: A successful Local Recovery Action has been performed by the SUM on the TRE, after 

detection of a recoverable failure (i.e., auto-restart failure, IOM disconnection).

10: A fatal exception has occurred on an SCP, or a SCP SW error has been detected in

operational state.

14: The TS reconfiguration has failed in the operational state because the TS was already active.

19: A fatal error has been reported by a layer 1 DSP concerning the radio in operational state.

20: Restart due to a watchdog reset for an unknown reason.

22: A fault has been detected at the ECPL interface management in operational state.

23: A DSP has reported a fatal error in its internal processing in the operational state.

24: At least one DSP has not answered the SCP polling in the operational state.

25: A fatal error has been reported by a layer 1 DSP or MBED on a serial internal interface in

the operational state.

26: FN_SUP timer (FN supervision) elapsed in the operational state: FCLK interrupt is missing.

27: Internal FNs from layer 1 are not consistent in the operational state.

28: MC-RRH Protocol Error 

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

109-1

Page 466: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 466/549

Impacts

Description

During the restart, the TRE looses all its calls, but after the restart, the TRE is again usable.

Impact BSS Cell(s) Signaling Calls

Loss - - - X

Degradation - X X -

BTS 9100 corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

If the TRE restarts consecutively after a short period, the parameters sent are

corrupted, or there may be a TRE hardware problem.

[10,248] RESTART [10,248] RESTART (TRE)

Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

109-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 467: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 467/549

Figure 109-1 RESTART (TRE): BTS 9100 corrective actions

[10,248] RESTART [10,248] RESTART (TRE)

BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

109-3

Page 468: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 468/549

BTS 9110/9110-E corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

[10,248] RESTART [10,248] RESTART (TRE)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

109-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 469: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 469/549

Figure 109-2 RESTART (TRE): BTS 9110/9110-E corrective actions

[10,248] RESTART [10,248] RESTART (TRE)

BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

109-5

Page 470: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 470/549

Distributed BTS corrective actions

Description

Figure 109-3 RESTART (TRE): Distributed BTS corrective actions

[10,248] RESTART [10,248] RESTART (TRE)

Distributed BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

109-6   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 471: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 471/549

[10,248] RESTART (RA)

Definition

Description

specific Problems   RESTART

event Type   Processing Error 

probable Cause   Application Subsystem Failure

perceived Severity   Warning (MI)

Alarm Description   The ANX/ANC has (auto)restarted successfully.

Alarm Number 1: A fatal exception has occurred on LP, or a LP SW error has been detected in the operational

state.

2: Watchdog reset has occurred.

3: A successful Local Recovery Action has been performed by the OMU on the ANX/ANC,

after detection of a recoverable failure (i.e., auto-restart failure, IOM disconnection).

Impacts

Description

Telecom functions are not affected.

Impact BSS Cell(s) Signaling Calls

Loss - -   - -

Degradation   -   - - -

[10,248] RESTART [10,248] RESTART (RA)

Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

109-7

Page 472: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 472/549

Corrective actions

Description

Note: Disable RF Power

Use the BTS NEM to disable RA before disconnecting RF cables.

Initialize RA after work.

If the ANX/ANC restarts consecutively after a short period, the parameters sent are

corrupted, or there may be a ANX/ANC hardware problem.

[10,248] RESTART [10,248] RESTART (RA)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

109-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 473: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 473/549

Figure 109-4 RESTART (RA): corrective actions

[10,248] RESTART [10,248] RESTART (RA)

Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

109-9

Page 474: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 474/549

[10,248] RESTART    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

109-10   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 475: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 475/549

110   110[10, 249] SMART-RESTART

Definition

Description

specific Problems   SMART-RESTART

event Type   Processing Error 

probable Cause   Application Subsystem Failure

perceived Severity   Warning (MI)

Alarm Description   The TRE has (auto)restarted successfully without loosing telecom traffic.

Alarm Number 3: A successful Local Recovery Action has been performed by the SUM on the TRE, after 

detection of a recoverable failure (i.e., auto-restart failure, IOM disconnection).

14: The TS reconfiguration has failed in the operational state because the TS was already active

19: A fatal error has been reported by a layer 1 DSP concerning the radio in operational state.

20: Restart due to a watchdog reset for an unknown reason.

22: A fault has been detected at the ECPL interface management in operational state.23: A DSP has reported a fatal error in its internal processing in the operational state.

24: At least one DSP has not answered to the SCP polling in the operational state

25: A fatal error has been reported by a layer 1 DSP or MBED on a serial internal interface in

the operational state.

26: FN_SUP timer (FN supervision) elapsed in the operational state: FCLK interrupt is missing.

27: Internal FNs from layer 1 are not consistent in the operational state.

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

110-1

Page 476: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 476/549

Impacts

Description

The TRE is auto-restarted with call preservation. That means that the TRE (including SCP and DSP) is restarted in a way that ongoing

calls are not dropped. After the successful restart the TRE will be fully usable again.

Impact BSS Cell(s) Signaling Calls

Loss - - - -

Degradation - X X X

Corrective actions

Description

 None.

The module is auto-restarted with call preservation. If the alarm persists, contact

Alcatel-Lucent support.

[10, 249] SMART-RESTART    Impacts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

110-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 477: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 477/549

Part IX: Class 11: BTS-TRANS

alarms

Overview

Purpose

This section defines the alarms for the Class 11: BTS-TRANS alarms.

Contents

Chapter 111, [11,22] LOOP-TO-EQUIPMENT 111-1

Chapter 112, [11,50] LOSS-OF-INCOMING-SIGNAL 112-1

Chapter 113, [11,66] AIS-2M 113-1

Chapter 114, [11,81] LOSS-OF-FRAME-ALIGNMENT 114-1

Chapter 115, [11,86] LOSS-OF-CRC-MULTIFRAME-ALIGNMENT 115-1

Chapter 116, [11,99] ERROR-RATE >E-3 116-1

Chapter 117, [11,100] ERROR-RATE >E-4 117-1

Chapter 118, [11,102] ERROR-RATE >E-6 118-1

Chapter 119, [11,176] REMOTE-ALARM-INDICATION 119-1

Chapter 120, [11,177] PPP ALL1 120-1

Chapter 121, [11,178] PPP NO RECEIPT OF HDLC SIGNAL 121-1

Chapter 122, [11,179] PPP RECEIPT OF TERMINATE 122-1

Chapter 123, [11,180] HDLC HIGH ERRONEOUS FRAMES RATIO 123-1

Chapter 124, [11,181] HDLC MEDIUM ERRONEOUS FRAMES RATIO 124-1

Chapter 125, [11,182] HDLC LOW ERRONEOUS FRAMES RATIO 125-1

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

IX-1

Page 478: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 478/549

Class 11: BTS-TRANS alarms   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

IX-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 479: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 479/549

111   111[11,22] LOOP-TO-

EQUIPMENT

Definition

Description

specific Problems   LOOP-TO-EQUIPMENT

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA), Warning (MI)

Alarm Description   An external loop is closed on an interface of the module. All channels on this interface (OML,

RSL, TCH) are looped back.

Alarm Number 1: An external loop is closed (in DSWICH) on Abis interface of the module.

2: An external loop is closed (in DSWICH) on BSII interface of the module.

Impacts

Description

As long as the loop is closed, the concerned channels are not available.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

111-1

Page 480: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 480/549

BTS 9100 corrective actions

Description

Figure 111-1 LOOP-TO-EQUIPMENT: BTS 9100 corrective actions

[11,22] LOOP-TO-EQUIPMENT    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

111-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 481: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 481/549

BTS 9110/9110-E corrective actions

Description

Figure 111-2 LOOP-TO-EQUIPMENT: BTS 9110/9110-E corrective actions

[11,22] LOOP-TO-EQUIPMENT    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

111-3

Page 482: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 482/549

[11,22] LOOP-TO-EQUIPMENT    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

111-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 483: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 483/549

112   112[11,50] LOSS-OF-

INCOMING-SIGNAL

Definition

Description

specific Problems   LOSS-OF-INCOMING-SIGNAL

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA), Warning (MI)

Alarm Description   There is a loss of incoming 2 Mbit/s signal on the Abis link.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

112-1

Page 484: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 484/549

BTS 9100 corrective actions

Description

Figure 112-1 LOSS-OF-INCOMING-SIGNAL: BTS 9100 corrective actions

[11,50] LOSS-OF-INCOMING-SIGNAL   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

112-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 485: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 485/549

BTS 9110/9110-E corrective actions

Description

Figure 112-2 LOSS-OF-INCOMING-SIGNAL: BTS 9110/9110-E corrective actions

[11,50] LOSS-OF-INCOMING-SIGNAL   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

112-3

Page 486: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 486/549

[11,50] LOSS-OF-INCOMING-SIGNAL   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

112-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 487: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 487/549

113   113[11,66] AIS-2M

Definition

Description

specific Problems   AIS-2M

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA), Warning (MI)

Alarm Description   The 2 Mbit/s interface is receiving a AIS signal (all one indication).

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

113-1

Page 488: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 488/549

9100 BTS corrective actions

Description

Figure 113-1 AIS-2M: 9100 BTS corrective actions

[11,66] AIS-2M   9100 BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

113-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 489: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 489/549

9110 Micro BTS/9110-E Micro BTS corrective actions

Description

Figure 113-2 AIS-2M: 9110 Micro BTS/9110-E Micro BTS corrective actions

[11,66] AIS-2M   9110 Micro BTS/9110-E Micro BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

113-3

Page 490: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 490/549

Page 491: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 491/549

114   114[11,81] LOSS-OF-FRAME-

ALIGNMENT

Definition

Description

specific Problems   LOSS-OF-FRAME-ALIGNMENT

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA), Warning (MI)

Alarm Description   There is a loss of frame alignment on the Abis link.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

114-1

Page 492: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 492/549

BTS 9100 corrective actions

Description

Figure 114-1 LOSS-OF-FRAME-ALIGNMENT: BTS 9100 corrective actions

[11,81] LOSS-OF-FRAME-ALIGNMENT    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

114-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 493: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 493/549

BTS 9110/9110-E corrective actions

Description

Figure 114-2 LOSS-OF-FRAME-ALIGNMENT: BTS 9110/9110-E corrective actions

[11,81] LOSS-OF-FRAME-ALIGNMENT    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

114-3

Page 494: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 494/549

[11,81] LOSS-OF-FRAME-ALIGNMENT    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

114-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 495: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 495/549

115   115[11,86] LOSS-OF-CRC-

MULTIFRAME-ALIGNMENT

Definition

Description

specific Problems   LOSS-OF-CRC-MULTIFRAME-ALIGNMENT

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA), Warning (MI)

Alarm Description   The CRC is not used at the remote end or there may be interferences on the connection.

The CRC multiframe alignment on the Abis link is lost.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

115-1

Page 496: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 496/549

BTS 9100 corrective actions

Description

Figure 115-1 LOSS-OF-CRC-MULTIFRAME-ALIGNMENT: BTS 9100 corrective actions

[11,86] LOSS-OF-CRC-MULTIFRAME-ALIGNMENT    BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

115-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 497: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 497/549

BTS 9110/9110-E corrective actions

Description

Figure 115-2 LOSS-OF-CRC-MULTIFRAME-ALIGNMENT: BTS 9110/9110-E corrective

actions

[11,86] LOSS-OF-CRC-MULTIFRAME-ALIGNMENT    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

115-3

Page 498: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 498/549

[11,86] LOSS-OF-CRC-MULTIFRAME-ALIGNMENT    BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

115-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 499: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 499/549

116   116[11,99] ERROR-RATE >E-3

Definition

Description

specific Problems   ERROR-RATE>E-3

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA), Warning (MI)

Alarm Description   The error rate of the incoming main system signal on the Abis link is worse than the threshold

value E-3.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

116-1

Page 500: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 500/549

BTS 9100 corrective actions

Description

Figure 116-1 ERROR-RATE>E-3: BTS 9100 corrective actions

[11,99] ERROR-RATE >E-3   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

116-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 501: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 501/549

BTS 9110/9110-E corrective actions

Description

Figure 116-2 ERROR-RATE>E-3: BTS 9110/9110-E corrective actions

[11,99] ERROR-RATE >E-3   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

116-3

Page 502: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 502/549

[11,99] ERROR-RATE >E-3   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

116-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 503: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 503/549

Page 504: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 504/549

BTS 9100 corrective actions

Description

Figure 117-1 ERROR-RATE>E-4: BTS 9100 corrective actions

[11,100] ERROR-RATE >E-4   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

117-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 505: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 505/549

BTS 9110/9110-E corrective actions

Description

Figure 117-2 ERROR-RATE>E-4: BTS 9110/9110-E corrective actions

[11,100] ERROR-RATE >E-4   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

117-3

Page 506: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 506/549

[11,100] ERROR-RATE >E-4   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

117-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 507: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 507/549

118   118[11,102] ERROR-RATE >E-6

Definition

Description

specific Problems   ERROR-RATE>E-6

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Minor (DMA), Warning (MI)

Alarm Description   The error rate of the incoming main system signal in Abis is worse than the threshold value E-6.

Impacts

Description

LMT:

The corresponding Abis link is possibly degraded.

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS is possibly degraded.

Case 2, link in other direction is concerned: The link to the other BTS in the chain is possibly degraded.

Impact BSS Cell(s) Signaling Calls

Loss - -   - -

Degradation   -   - (X) (X)

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

118-1

Page 508: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 508/549

BTS 9100 corrective actions

Description

Figure 118-1 ERROR-RATE>E-6: BTS 9100 corrective actions

[11,102] ERROR-RATE >E-6   BTS 9100 corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

118-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 509: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 509/549

BTS 9110/9110-E corrective actions

Description

Figure 118-2 ERROR-RATE>E-6: BTS 9110/9110-E corrective actions

[11,102] ERROR-RATE >E-6   BTS 9110/9110-E corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

118-3

Page 510: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 510/549

Page 511: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 511/549

Page 512: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 512/549

9100 BTS corrective actions

Description

Figure 119-1 9100 BTS corrective actions

[11,176] REMOTE-ALARM-INDICATION    9100 BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

119-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 513: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 513/549

9110 Micro BTS/9110-E Micro BTS corrective actions

Description

Figure 119-2 9110 Micro BTS/9110-E Micro BTS corrective actions

[11,176] REMOTE-ALARM-INDICATION    9110 Micro BTS/9110-E Micro BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

119-3

Page 514: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 514/549

[11,176] REMOTE-ALARM-INDICATION    9110 Micro BTS/9110-E Micro BTS corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

119-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 515: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 515/549

120   120[11,177] PPP ALL1

Definition

Description

specific Problems   PPP ALL1

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA)

Alarm Description   All 1s are detected in PPP frames on BTS side.

Alarm Number 1: PPPAll1.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

120-1

Page 516: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 516/549

Corrective actions

Description

Figure 120-1 PPP ALL1: corrective actions

[11,177] PPP ALL1   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

120-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 517: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 517/549

121   121[11,178] PPP NO RECEIPT

OF HDLC SIGNAL

Definition

Description

specific Problems   PPP NO RECEIPT OF HDLC SIGNAL

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA)

Alarm Description   No HDLC signal is received on the BTS side.

Alarm Number 1: PPP No Receipt of HDLC Signal.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

121-1

Page 518: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 518/549

Corrective actions

Description

Figure 121-1 PPP NO RECEIPT OF HDLC SIGNAL: corrective actions

[11,178] PPP NO RECEIPT OF HDLC SIGNAL   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

121-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 519: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 519/549

122   122[11,179] PPP RECEIPT OF

TERMINATE

Definition

Description

specific Problems   PPP RECEIPT OF TERMINATE

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA)

Alarm Description   The BTS side received a Terminate signal.

Alarm Number 1: PPP Receipt of Terminate.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

122-1

Page 520: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 520/549

Corrective actions

Description

Figure 122-1 PPP RECEIPT OF TERMINATE: corrective actions

[11,179] PPP RECEIPT OF TERMINATE    Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

122-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 521: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 521/549

123   123[11,180] HDLC HIGH

ERRONEOUS FRAMES RATIO

Definition

Description

specific Problems   HDLC HIGH ERRONEOUS FRAMES RATIO

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA)

Alarm Description   High ratio of HDLC failures (CRC, frames too long, frames too short, receipt of abort).

Alarm Number 1: PPP High Erroneous Frames Ratio.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

123-1

Page 522: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 522/549

Corrective actions

Description

Figure 123-1 PPP HIGH ERRONEOUS FRAMES RATIO: corrective actions

[11,180] HDLC HIGH ERRONEOUS FRAMES RATIO   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

123-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 523: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 523/549

124   124[11,181] HDLC MEDIUM

ERRONEOUS FRAMES RATIO

Definition

Description

specific Problems   HDLC MEDIUM ERRONEOUS FRAMES RATIO

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA)

Alarm Description   Medium ratio of HDLC failures (CRC, frames too long, frames too short, receipt of abort).

Alarm Number 1: PPP Medium Erroneous Frames Ratio.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

124-1

Page 524: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 524/549

Corrective actions

Description

Figure 124-1 PPP MEDIUM ERRONEOUS FRAMES RATIO: corrective actions

[11,181] HDLC MEDIUM ERRONEOUS FRAMES RATIO   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

124-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 525: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 525/549

125   125[11,182] HDLC LOW

ERRONEOUS FRAMES RATIO

Definition

Description

specific Problems   HDLC LOW ERRONEOUS FRAMES RATIO

event Type   Equipment

probable Cause   Indeterminate

perceived Severity   Major (PMA)

Alarm Description   Low ratio of HDLC failures (CRC, frames too long, frames too short, receipt of abort).

Alarm Number 1: PPP Low Erroneous Frames Ratio.

Impacts

Description

LMT:

The corresponding Abis link is lost. If the link towards the BSC is concerned, the BTS is lost (if no redundancy).

OMC:

Case 1, the link towards the BSC is concerned: The Abis link to the BTS was lost. The Abis link is reestablished and allows the alarm

reception (otherwise, without Abis link, no alarms are reported to the OMC).

Case 2, link in other direction is concerned: The other BTS in the chain are lost.

Impact BSS Cell(s) Signaling Calls

Loss - X   X X

Degradation   -   - - -

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

125-1

Page 526: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 526/549

Corrective actions

Description

Figure 125-1 PPP LOW ERRONEOUS FRAMES RATIO: corrective actions

[11,182] HDLC LOW ERRONEOUS FRAMES RATIO   Corrective actions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

125-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 527: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 527/549

Page 528: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 528/549

Page 529: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 529/549

126   126BTS Alarms with Additional

Information

Overview

Purpose

This section describes the BTS alarms that can provide additional information. Depending

on the alarm, the additional information can comprise one or more TLV codes.

Contents

[2,247] 126-2

TLV code 126-2

[2,248] 126-3

TLV code 126-3

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

126-1

Page 530: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 530/549

[2,247]

TLV code

Description

The coding of the additional information for this alarm depends on the alarm number, as

shown in . This information is only provided if the OMU has battery backup for its RAM.

Table 126-1 Alarm [2,247] TLV Codes

Alarm Number Bytes Coding

4 1 - 5

6 - 24

TLV120

TLV83

5 1 - 5

6 - 37

TLV120

TLV84

6 1 - 5

6 - 24

TLV120

TLV83

7 1 - 5

6 - 176

TLV120

TLV82

BTS Alarms with Additional Information[2,247] 

TLV code

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

126-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 531: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 531/549

[2,248]

TLV code

Description

The coding of the additional information for this alarm depends on the alarm number, as

shown in .

Table 126-2 Alarm [2,248] TLV Codes

Alarm Number Bytes Coding

1 1 - 5

6 - 37

TLV120

TLV84

3 1 - 5

6 - 24

TLV120

TLV83

4 1 - 5

6 - 176

TLV120

TLV82

BTS Alarms with Additional Information[2,248] 

Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

126-3

Page 532: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 532/549

BTS Alarms with Additional Information   TLV code

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

126-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 533: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 533/549

127   127TLV coding

Overview

Purpose

Additional information is provided in the form of Tag Length Value (TLV) codes that

describe system automatic test results. The first two bytes of additional information definethe TLV code identity number. The third byte defines the number of succeeding bytes,

including itself, that comprise the message.

Contents

TLV 81 coding 127-3

Description 127-3

TLV49 coding 127-4

Description 127-4

TLV59 coding 127-5

TLV59 for TRE faults of 9100 BTS 127-5

TLV59 for AN faults of 9100 BTS 127-7

TLV59 for TRANS&CLOCK faults of 9100 BTS 127-8

TLV61 coding 127-9

Definitions 127-9

TLV82 coding 127-11

Description 127-11

TLV83 coding 127-13

Description 127-13

TLV84 coding 127-15

Description 127-15

...................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

127-1

Page 534: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 534/549

TLV120 coding 127-16

Description 127-16

TLV243 coding 127-17

Description 127-17

TLV coding   Overview

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

127-2   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 535: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 535/549

TLV 81 coding

Description

For the CU SBL

In case of alarm sent by TRE:

•   TLV 49 ('FU HW Cap', as received from TRE at re-/ config time)

•   TLV 243 ('BTS_HW_Family')

•   TLV 59 ('Fault_Info' from TRE) optional

•   TLV 61 ('Detailed_Results' from TRE) optional (n times, n>=1)

For the RA SBL

In case of alarm sent by ANX:

•   TLV 59 ('Fault_Info' from ANX/ANC) optional

•   TLV 61 ('Detailed_Results' from ANX/ANC) optional (n times, n>=1)

For the CLLK SBL

In case of alarm sent by TRANS & CLOCK / SUM:

•   TLV 59 ('Fault_Info' from TRANS & CLOCK / SUM) optional

•   TLV 61 ('Detailed_Results' from TRANS & CLOCK / SUM) optional (n times, n>=1)

For the OMU SBL

In case of OMU autorestart / autoreset:

•   TLV 120 ('OMU HW characteristics') optional

•   TLV 82 ('Additional info for m*P exceptions') optional

•   TLV 83 ('Additional info for Scenario problems') optional

•   TLV 84 ('Additional info for Lack of resources') optional

TLV codingTLV 81 coding

Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

127-3

Page 536: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 536/549

TLV49 coding

Description

Definitions

Bytes Description - FU HW Capability

2 Element Identifier ( = 49)

1 Length (=4)

1 FU Generation 0 = G1 FU, G2 FU3

1 = G2 FU2

2 = G2 Micro BTS

3 = DR-FU

4 = 9100 TRE

FF = unknown

1 FR/DR bits 7 to 3 - unused (bit 7 is hi-order bit on the left)

 bit 2 Enhanced Full Rate -Not Provided (0) Provided (1)

 bit 1 Full Rate -Not Provided (0) Provided (1

 bit 0 Half Rate -Not Provided (0) Provided (1)

1 FU CIPHERING

CAPABILITY

 bit 7 Encryption with A5/7 algorithm - Not Provided (0) Provided (1)

 bit 6 Encryption with A5/6 algorithm - Not Provided (0) Provided (1)

 bit 5 Encryption with A5/5 algorithm - Not Provided (0) Provided (1)

 bit 4 Encryption with A5/4 algorithm - Not Provided (0) Provided (1)

 bit 3 Encryption with A5/3 algorithm - Not Provided (0) Provided (1)

 bit 2 Encryption with A5/2 algorithm - Not Provided (0) Provided (1)

 bit 1 Encryption with A5/1 algorithm - Not Provided (0) Provided (1)

 bit 0 No Encryption - always 1 = provided (always possible)

FF = all algorithms supported. )) never sent by the FUunknown.

1 RSL RATE

CAPABILITY

 bits 7 to 2 - unused (bit 7 is hi-order bit on the left)

 bit 1 = 64 Kb/sec - Not Provided (0) Provided (1)

 bit 0 = 16 Kb/sec - Not Provided (0) Provided (1)

FF = unknown

TLV codingTLV49 coding

Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

127-4   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 537: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 537/549

TLV59 coding

TLV59 for TRE faults of 9100 BTS

TLV59 is used for reporting TRE, AN and TRANS&CLOCK Alarm Type for BTS.

Table 127-1, “TLV59 for TRE faults of 9100 BTS” (p. 127-5) shows the definitions of 

TLV 59 for the TRE faults (9100 BTS only). EVAD indicates the faultcondition: 1 =

Eventtype (EV), 0 = Appearance/Disappearance type (AD). AD indicates the

Appearance/Disappearance state; 1 = Appearance (ON), 0 = Disappearance (OFF).

Table 127-1 TLV59 for TRE faults of 9100 BTS

ALATYP ALAN EVAD Description of Fault Code

1   0 AD   CLKI clock failure (1)

5   0 AD   CLKI frame failure

6   0 AD   RSL LAPD link failure

9   0 AD   Non fatal temperature failure

13   0 AD   TRE VSWR failure (1)

20 Recoverable failure

0 EV Microprocessor failure

21 EV BCCH failure

22 EV Algorithm failure

23 EV TLC_CONFIG_T expiry

24 EV TS reconfiguration failure

25 EV SYS INFO 3 failure

27 EV BCCH_CUT timeout

28 EV Radio failure

29 EV ECPL failure

30 EV L1 DSP failure

31 EV L1 DSP no response failure

32 EV Internal serial interface failure

33 EV FCLK IT failure

34 EV Internal FN failure

21   Handover/Power control algorithms configuration refused

0 EV Missing message

25   TRE fatal failure (1)

TLV codingTLV59 coding

TLV59 for TRE faults of 9100 BTS

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

127-5

Page 538: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 538/549

Page 539: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 539/549

TLV59 for AN faults of 9100 BTS

Description

Table 127-2, “TLV59 for TRANS&CLOCK faults of 9100 BTS” (p. 127-7)  shows the

definitions of TLV 59 for the TRANS&CLOCK faults (9100 BTS only). EVAD indicatesthe faultcondition: 1 = Eventtype (EV), 0 = Appearance/Disappearance type (AD). AD

indicates the Appearance/Disappearance state; 1 = Appearance (ON), 0 = Disappearance

(OFF).

Table 127-2 TLV59 for TRANS&CLOCK faults of 9100 BTS

ALATYP ALAN EVAD Description of Fault Code

1   0 AD   CLKI clock failure

2 LNA failure

0 AD LNA 1 partial failure

1 AD LNA 2 partial failure

2 AD LNA 1 total failure

3 AD LNA 2 total failure

4   0 AD   VSWR circuitry failure

5   0 AD   CLKI frame failure

7 Antenna VSWR failure

0 AD AN1_VSWR1_AL

1 AD AN2_VSWR1_AL

2 AD AN1_VSWR2_AL

3 AD AN2_VSWR2_AL

14   0 AD Microprocessor failure

15   0 AD HW failure

16   0 AD SW failure

17   0 AD Configuration failure

18   0 AD SW activation failure

19   0 AD Downloading failure

20 Recoverable failure

0 EV Microprocessor failure

10 EV Watchdog reset

TLV codingTLV59 coding

TLV59 for AN faults of 9100 BTS

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

127-7

Page 540: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 540/549

TLV59 for TRANS&CLOCK faults of 9100 BTS

Description

Table 127-3, “TLV59 for TRANS&CLOCK faults of 9100 BTS” (p. 127-8)  shows the

definitions of TLV 59 for the TRANS&CLOCK faults (9100 BTS only). EVAD indicatesthe faultcondition: 1 = Eventtype (EV), 0 = Appearance/Disappearance type (AD). AD

indicates the Appearance/Disappearance state; 1 = Appearance (ON), 0 = Disappearance

(OFF).

Table 127-3 TLV59 for TRANS&CLOCK faults of 9100 BTS

ALATYP ALAN EVAD Description of Fault Code

3 Internal CLOCK failure

0 AD   FN input from master lost

1 AD   Frame signal input from master lost

2 AD   Reference clock input from master lost

3 AD   PCM synchronization unusable

4 AD   GPS synchronization lost

8   0 AD   Oven warm up alarm

14   0 AD Microprocessor failure

16   0 AD SW failure

18   0 AD SW activation failure

19   0 AD Downloading failure

20 Recoverable failure

0 EV Microprocessor failure

10 EV Watchdog reset

25 TRANS&CLOCK fatal failure (1)

1 AD HW failure

3 AD Internal Clock failure

(1) As this alarm is fatal for the module, no alarm disappearance indication is supplied.

The alarm disappearance is detected on Alarm In Force List report.

TLV codingTLV59 coding

TLV59 for TRANS&CLOCK faults of 9100 BTS

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

127-8   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 541: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 541/549

TLV61 coding

Definitions

TLV61 Bytes

The TLV61 byte definitions are shown in Table Table 127-4, “TLV61 Bytes” (p. 127-9).

Table 127-4 TLV61 Bytes

Bytes Description

2 Element Identifier (=61)

1 or 2 Length (2 bytes if length > 127 (1)

2 Board Identification

1 Result type

Variable Results (maximum length is 40 bytes).

Notes:

1. For TRE, only one byte is forseen, because the length of the data is < 127 bytes.

TLV61, even if indicated, may not appear in an alarm message. Internal FU problems,

such as a blocked internal bus or a hardware fault, can prevent the FU controller from

receiving it. Several TLV61s can be sent.

* The boards (CDCC, CECC, ...) are numbered as in the rack, starting from the left hand

side (Mark I only).

TLV61 Board Identification Bytes for 9100 BTS

The definition of the Board Identification bytes for 9100 BTS is shown in Table 127-5,

“TLV61 Board Identification Bytes for 9100 BTS” (p. 127-9). A bit set to 1 identifies the

 board at the origin of the fault detection.

Table 127-5 TLV61 Board Identification Bytes for 9100 BTS

Bit Number TRE (1) ANX/ANC TRANS&CLOCK (9100

BTS only)

0 ENCT - CLOCK  

1 DEC VSWR TRANS

2 DEM0 LNA -

3 DEM1 - -

TLV codingTLV61 coding

Definitions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

127-9

Page 542: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 542/549

Table 127-5 TLV61 Board Identification Bytes for 9100 BTS (continued)

Bit Number TRE (1) ANX/ANC TRANS&CLOCK (9100

BTS only)

4 MBED - -

5 CUL - -

6 SCP Microprocessor -

(1) The bit positions are fixed by the Host interface within the TRE.

TLV codingTLV61 coding

Definitions

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

127-10   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 543: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 543/549

Page 544: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 544/549

Bytes Description - Watchdog Reset

4 Task name

2 Status register  

4 User stack pointer  

4 Interrupt stack pointer  

4 Data register 0

4 Data register 1

4 Data register 2

4 Data register 3

4 Data register 4

4 Data register 5

4 Data register 6

4 Data register 7

4 Address register 0

4 Address register 1

4 Address register 2

4 Address register 3

4 Address register 4

4 Address register 5

4 Address register 6

92 Complete STACK Frame

1 Board Status Register (see relevant OMU HW Functional Description).

TLV codingTLV82 coding

Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

127-12   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 545: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 545/549

TLV83 coding

Description

Definition

The TLV83 byte definitions are shown in Table 127-6, “TLV83 Bytes” (p. 127-13).

Table 127-6 TLV83 Bytes

Bytes Description - Scenario Problems

2 Element Identifier ( = 83)

1 Length ( = 16)

4 Taskname The name of the task that triggered the autorestart/autoreset (ASCII coded).

4 SBL Id. The SBL on which the scenario was running, where:

 byte 1 +

2

SBL type

 byte 3 SBL number 

 byte 4 SBL sub-number 

2 Internal Message Identifier 

Used to identify the internal scenario.

2 External Reference Number.

Used to identify the external (Abis or MMI) scenario (0 = autonomous).

2 Scenario Message Identifier.

Used to identify the external or autonomous scenario.

1 Origin of Action

0 Operator command triggered from OMC-R.

1 Operator command triggered from BSC terminal.

2 Operator command triggered from BTS NEM.

4 Autonomous system action.

5 Unknown.

1 Failure Description.

Indicates the reason for an autoreset (i.e., the reason for returning to bootstrap). If a second autoreset occurs

during a download, then the first reason is maintained.

1 Three unsuccessful autorestarts.

2 No download after being in bootstrap for > 24 hours (sending BTS-OMU-STARTED). This is the behaviour 

of the release 1 and 2 OMU PROM (and should be changed with the next PROM release).

TLV codingTLV83 coding

Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

127-13

Page 546: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 546/549

Table 127-6 TLV83 Bytes (continued)

Bytes Description - Scenario Problems

FF (hex) No information (e.g. for restart due to internal scenario Time out).

TLV codingTLV83 coding

Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

127-14   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 547: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 547/549

TLV84 coding

Description

Definition

The TLV84 byte definitions are shown in Table 127-7, “TLV84 Bytes” (p. 127-15).

Table 127-7 TLV84 Bytes

Bytes Description - Lack of Resources

2 Element Identifier ( = 84)

1 Length ( = 69)

4 Taskname The name of the task that triggered the autorestart/autoreset (ASCII coded).

1 Required Memory Region.

The requested memory region.

0 Message buffer.

1 Memory allocation.

2 Memory re-allocation.

4 Required Memory Size.

The requested memory size in octets.

60 Stackinfo Information taken directly from the stack:

•   Supervisor mode - the system stack 

•   User mode - the stack of a particular task.

TLV codingTLV84 coding

Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12Issue 4 September 2012

Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

127-15

Page 548: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 548/549

TLV120 coding

Description

Definition

The TLV120 byte definitions are shown in Table 127-8, “TLV120 Bytes” (p. 127-16).

Table 127-8 TLV120 Bytes

Bytes Description

2 Element Identifier ( = 120)

1 Length ( = 3)

1 Hardware revision:

0 - Hardware 1 (serial test interface, volatile memory).1 - Hardware 2 (parallel test interface, non-volatile memory).

1 RAM size - given as the number of 4 Mbyte blocks.

1 Flash EPROM:

0 - Not equipped or not accessible.

1 - Equipped.

TLV codingTLV120 coding

Description

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

127-16   Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements

Alcatel-Lucent BTS9YZ-03803-1330-PCZZA B12

Issue 4 September 2012

Page 549: Alarm Dictionary

8/12/2019 Alarm Dictionary

http://slidepdf.com/reader/full/alarm-dictionary 549/549

TLV243 coding

Description

Definition

The TLV243 byte definitions are shown in Table 127-9, “TLV243 Bytes” (p. 127-17).

Table 127-9 TLV243 Bytes

TLV codingTLV243 coding

Description

....................................................................................................................................................................................................................................