aesculap orthopaedics mios instruments...these instruments support the surgeon during less invasive...
TRANSCRIPT
Minimally Invasive Orthopaedic Solutions
Aesculap OrthopaedicsMIOS™ Instruments
The MIOS knee instruments are designed forvarious surgical approaches in navigated andmanual total knee arthroplasty. They help tooptimize the field of vision in both less invasive and standard approaches.
2
MIOS™ - Instruments for Knee Arthroplasty
The MIOS instruments offer the following advantages:
� Wide range of retractor designs
� Instrument curvatures adapted for optimal results
� Ergonomic grips for easier handling
� Color coding for easy organization
� The number of assistants required can be reduced by using a retaining strap
3
The MIOS™ Instrument Range
MIOS Curved Hohmann, NarrowModified Hohmann lever, narrow, 45° curvature, short blunt tip
FK201R
MIOS Curved Hohmann, WideModified Hohmann lever, wide, 60° curvature, long blunt tip
FK202R
MIOS PCL Retractor 45° curvature, sharp U-shaped tip suitable for retracting the posterior cruciateligament away from the tibial resection field
FK203R
MIOS Collateral Ligament Retractor, Single Tip 180° curvature, narrow, short blunt tip for easy lateralization of the collateralligaments
FK205R
MIOS Patella Retractor180° curvature, wide, long blunt tip for easy lateralization of the patella
FK204R
FK206R MIOS Collateral Ligament Retractor, U-shaped Tip180° curvature, narrow, blunt U-shaped tip for easy lateralization of the collateral ligaments
MIOS Ventral Tissue Retractor for Implant InsertionFacilitates insertion of the femoral implant
FK208R
MIOS Curved Osteotome30° curvature, with ergonomic handle simplifies complete removal of the resected tibial bone
NQ948R
MIOS Patella Retractor, BroadBroad 180° curvature, wide, long blunt tip
FK209R
MIOS Patella Grasping ForcepsCurved handle facilitates subluxation of the patella
NQ974R
FK207R MIOS Ventral Tissue Retractor90° curvature with concave recess and sharp hook
4
MIOS – Instruments for Hip Arthroplasty
The MIOS hip retractors have the following advantages:
� Standardized shape and length
� Large, contoured surface for less wound stress
� Variable angles from 30° to 90°
� Different tip shapes for specific applications
� Modular handles
� Color coded grips for easy handling
� Possible combination with surgery frame
The Aesculap MIOS hip retractors are designed for various surgical approaches. These instrumentssupport the surgeon during less invasive and standard approaches.
5
Short Tip
V-tip U-tip
FemoralNeck Tip
1/4
1/4 1/4
1/4
1/4
Sharpor Blunt Tip
22 mm Narrow
28 mm Standard
40 mm Broad
MIOS – Hip Retractors Overview
FK211R MIOS 90° Narrow Sharp
FK212R MIOS 90° Standard Sharp
FK213R MIOS 90° Broad Sharp
FK214R MIOS 90° Narrow Short Tip
FK215R MIOS 90° Standard Short Tip
FK218R MIOS 90° Standard Blunt
FK219R MIOS 90° Broad Blunt
FK224R MIOS 90° Standard V-tip
FK239R MIOS 90° Femoral Neck Lever Narrow
MIOS-90°
MIOS-60°
MIOS-45°
MIOS-30°
FK223R MIOS-60° Standard V-tip
FK222R MIOS-45° Standard V-tip
1/3
1/3
FK243R MIOS-45° Standard Sharp
FK244R MIOS-45° Standard Blunt
FK245R MIOS-45° Broad Sharp
FK246R MIOS-45° Broad Sharp
1/3
FK221R MIOS-30° Standard V-tip
FK231R MIOS-30° Standard U-tip
FK238R MIOS-30° Femoral Neck Lever Narrow
FK241R MIOS-30° Narrow Sharp
1/3
6
Order information:
NE150R Leg Positioner for TKA
NE153R Fixation Frame
�
�
�
�
Allows for internal/externalrotation up to 10°
Moveable baseto adjust flexion
Rotational Boot
Easily lock/unlockposition of the base
Non sterile frame
MIOS™ – Leg Positioner
� Eliminates the need for a sandbag
� Easily adjust extension and flexion
� Consists of a rotational boot with base plate and a frame which is attached to the OR table
� Supports leg at the calf and on the base
� Foot rotation can be adjusted with the holding screw by ± 10°
� Rotational boot is locked to the move able sledge
� Leg is placed in the desired position
� Flexion and extension are adjusted by releasing and tightening the holding screw
Treatment: The leg holder is steam sterilizable. Theframe can not be sterilized, it should be treated like a part of the OR table.
7
MIOS™ – Optional Instruments
Modular Ergonomic Grips come in four different colors:
FK251 – Green
FK252 – Yellow
FK253 - Blue
FK254 - Red
MIOS Retractor Extension, StraightFK248R
MIOS Retractor Extension, 60° AngleFK249R
The MIOS Retractor Extensions and MIOS Ergonomic Grips can be combined with any Aesculap MIOS retractor for improved comfortand handling.
Aesculap Implant Systems, Inc.
3773 Corporate ParkwayCenter Valley, PA 18034Phone: 866-229-3002
www.aesculapimplantsystems.com©2008 AESCULAP. ALL RIGHTS RESERVED. PRINTED IN THE USA. DOC790 3M 8 /08Aesculap is an equal opportunity employer
All rights reserved. Technical alterations are possible. This leaflet may be used for no other purposes than offering, buying and selling of our products. No part may be copied or reproduced in any form. In the case of misuse we retain the rights to recall our catalogs and price lists and to take legal actions.