aerco low nox kc-1000 gas fired hot water boiler … · to minimize emissions while maximizing fuel...

2
To minimize emissions while maximizing fuel efficiency, KC-1000 gas-fired boilers can be equipped, or retrofit, with a low NOx burner whose emissions will consistently measure <30 ppm of NOx corrected to 3% excess oxygen at all firing rates when operated with natural gas. Certified by the South Coast Air Quality Management District (SCAQMD) and the Texas Commission on Environmental Quality (TCEQ) in its class, the fully modulating burner also maintains AERCO equipment standards for energy efficiency, longevity, reliability and construction quality. Designed for application in any closed loop hydronic system, the Low NOx KC-1000 gas-fired boiler precisely matches energy input to fluctuating system load, yielding seasonal efficiencies as high as 95%. Its efficiency actually increases as the load decreases due to its unique inverse efficiency curve. The boiler can be used singly or in modular arrangements for inherent standby with minimum space requirements. Venting flexibility permits installation without normal restrictions. The advanced electronics of each boiler module offer selectable modes of operation. The options available include: Constant Temperature Internal Setpoint Indoor/Outdoor Reset 4-20mA Linear Signal Response AERCO Boiler Management System Integration AERCO Combination Domestic Water/Boiler Plant Building Automation System Network Interface Regardless of the mode of operation, the load tracking capability of every unit delivers the ultimate in energy control through energy input modulation with an 11:1 ratio while meeting all load demands. With condensing capability, the Low NOx KC-1000 Boiler is ideally suited for modern low temperature as well as conventional heating systems. Because of the compact design with sidewall or conventional venting, the unit is appropriate for either new construction or retrofit application with the same excellent results. Efficiency, reliability, and longevity make the Low NOx KC-1000 Boiler a true step forward in heating system design. MODEL KC-1000 GWBLN TECHNICAL DATA KC-1000 Specifications BTU Input ……….…970,000 BTU/hr (Nat. Gas) † 1,000,000 BTU/hr (Propane) † Net output @ full input …834,200-902,100 BTU/H (Nat. Gas)* 860,000-930,000 BTU/H (Propane) ASME Working Pressure . . . . . . . . . . . . . . .150 PSIG Electrical Requirement . . . . . . . . . . . .120/1/60 20Amp Min. Gas Requirements @ Full Load ……8.8” WC (Nat. Gas) 7.7” WC (Propane) Max. Gas Requirements ……………………14” WC Vent Size . . . . . . . . . . . . . . . . . . . . . . . . . .6” Diameter Water Connections . . . . . . . . . .4” Flanged 150lb. ANSI Gas Connection . . . . . . . . . . . . . . . . . . . . .1-1/4” NPT Minimum Water Flow . . . . . . . . . . . . . . . . . . . .25 GPM Maximum Water Flow . . . . . . . . . . . . . . . . . .150 GPM Water Pressure Drop . . . . . . . . . . . .0.23 Ft. 100 GPM Water Volume . . . . . . . . . . . . . . . . . . . . . . .23 Gallons Control Range . . . . . . . . . . . . . . . . . . . .50°F to 220°F NOx Emissions Certification . . . . . . .SCAQMD,TCEQ Standard Listings & Approvals . . UL, CUL, CSD-1,ASME Optional Approval . . . . . . . . . . . . . . . . . . . . . . . . . .IRI Weight, Installed . . . . . . . . . . . . . . . . . . . . . . .1350 lbs. LOW NOx KC-1000 FEATURES NOx Emission <30ppm (natural gas operation) Natural Gas, Propane or Dual Fuel 11:1 Turndown Ratio Sidewall or Conventional Vent Capabilities ASME 150 PSIG Working Pressure Certified UL, CUL Listed, FM Compliant, ASME Coded *Output is dependent upon return water temp. and firing rate – see efficiency curves on reverse. †Up to 2000’ Altitude AERCO LOW NOx KC-1000 Gas Fired Hot Water Boiler System UL, CUL Listed for Alcove Installation on Combustible Flooring Quiet Operation throughout Firing Range Internal Low Water Cutoff and Dual Over Temperature Protection Compact Space Efficient Design Precise Temperature Control +/- 2°F Optional Sealed Combustion

Upload: duongdieu

Post on 15-Aug-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

To minimize emissions while maximizing fuel efficiency, KC-1000 gas-fired boilers can beequipped, or retrofit, with a low NOx burner whose emissions will consistently measure <30 ppmof NOx corrected to 3% excess oxygen at all firing rates when operated with natural gas. Certifiedby the South Coast Air Quality Management District (SCAQMD) and the Texas Commission onEnvironmental Quality (TCEQ) in its class, the fully modulating burner also maintains AERCOequipment standards for energy efficiency, longevity, reliability and construction quality.

Designed for application in any closed loop hydronic system, the Low NOx KC-1000 gas-firedboiler precisely matches energy input to fluctuating system load, yielding seasonal efficiencies as highas 95%. Its efficiency actually increases as the load decreases due to its unique inverse efficiencycurve. The boiler can be used singly or in modular arrangements for inherent standby with minimumspace requirements. Venting flexibility permits installation without normal restrictions.

The advanced electronics of each boiler module offer selectable modes of operation. The optionsavailable include:

Constant Temperature Internal SetpointIndoor/Outdoor Reset4-20mA Linear Signal ResponseAERCO Boiler Management System IntegrationAERCO Combination Domestic Water/Boiler PlantBuilding Automation System Network Interface

Regardless of the mode of operation, the load tracking capability of every unit delivers theultimate in energy control through energy input modulation with an 11:1 ratio while meetingall load demands.

With condensing capability, the Low NOx KC-1000 Boiler is ideally suited for modern lowtemperature as well as conventional heating systems. Because of the compact designwith sidewall or conventional venting, the unit is appropriate for either new constructionor retrofit application with the same excellent results. Efficiency, reliability, andlongevity make the Low NOx KC-1000 Boiler a true step forward in heatingsystem design.

MODEL KC-1000 GWBLNTECHNICAL DATA

KC-1000 SpecificationsBTU Input ……….…970,000 BTU/hr (Nat. Gas) †

1,000,000 BTU/hr (Propane) †Net output @ full input …834,200-902,100 BTU/H (Nat. Gas)*

860,000-930,000 BTU/H (Propane)ASME Working Pressure . . . . . . . . . . . . . . .150 PSIGElectrical Requirement . . . . . . . . . . . .120/1/60 20AmpMin. Gas Requirements @ Full Load ……8.8” WC (Nat. Gas)

7.7” WC (Propane)Max. Gas Requirements ……………………14” WCVent Size . . . . . . . . . . . . . . . . . . . . . . . . . .6” DiameterWater Connections . . . . . . . . . .4” Flanged 150lb. ANSI

Gas Connection . . . . . . . . . . . . . . . . . . . . .1-1/4” NPTMinimum Water Flow . . . . . . . . . . . . . . . . . . . .25 GPMMaximum Water Flow . . . . . . . . . . . . . . . . . .150 GPMWater Pressure Drop . . . . . . . . . . . .0.23 Ft. 100 GPMWater Volume . . . . . . . . . . . . . . . . . . . . . . .23 GallonsControl Range . . . . . . . . . . . . . . . . . . . .50°F to 220°FNOx Emissions Certification . . . . . . .SCAQMD,TCEQStandard Listings & Approvals . . UL, CUL, CSD-1,ASMEOptional Approval . . . . . . . . . . . . . . . . . . . . . . . . . .IRIWeight, Installed . . . . . . . . . . . . . . . . . . . . . . .1350 lbs.

LOW NOx KC-1000 FEATURES• NOx Emission <30ppm (natural gas operation)• Natural Gas, Propane or Dual Fuel• 11:1 Turndown Ratio• Sidewall or Conventional Vent Capabilities• ASME 150 PSIG Working Pressure Certified• UL, CUL Listed, FM Compliant, ASME Coded

*Output is dependent upon return water temp. and firing rate – see efficiency curves on reverse. †Up to 2000’ Altitude

AERCO LOW NOx KC-1000 Gas Fired Hot Water Boiler System

• UL, CUL Listed for Alcove Installation on Combustible Flooring• Quiet Operation throughout Firing Range• Internal Low Water Cuto� and Dual Over Temperature Protection• Compact Space E�cient Design• Precise Temperature Control +/- 2°F• Optional Sealed Combustion

1-1/4 NPT

c.g.

1"NPT DRAIN VALVE

AC SERVICE 3

PRESSURE

GAS INLET

AIR INLET

CONNECTION

RELIEF VALVE

29

68-1/4

2316-1/2

77-1/8OVERALLHEIGHT

72-1/2

4-150# FLG'DWATER OUTLET

WATER INLET4-150# FLG'D

CONNECTIONCONTROL

35

4'-9"Depth

24" 22-1/4"Minimum

9'-6-3/4" Overall Length

Typical Modular Boiler Dimensions (KC-1000-3)

ALL DIMENSIONS AND SIZESSHOWN ARE IN INCHES. CERTIFIED DRAWINGS ARE AVAILABLE ON REQUEST.

DIMENSIONS ARE SUBJECT TO CHANGE.

HEAT EXCHANGES • WATER HEATERS • BOILERSCONTROL VALVES • STEAM GENERATORS

AERCO INTERNATIONAL, INC. • 159 PARIS AVE.NORTHVALE, N.J. 07647-0128 • (201) 768-2400 • FAX 201-768-7789

www.aerco.com • E-mail: [email protected]

Represented by:

noitarepO fo sedoM elbammargorPsevruC ycneiciffE

Specifications subject to change.Consult website or contact AERCO.GFB-2 02/08 Revised DOC 06/10

Ratings and Dimensions

(a) Style to be determined by individual application requirement. (c) Output dependent upon application – see efficiency curves.(b) Altitude below 2,000’. Apply Altitude Correction Factor above 2,000’. (d) Output shown for natural gas operation.

Modules Model (a)

Mbh Input (b)

Mbh Output (b) (c) (d)

Width (1)

Depth Height Weight(wet)

One(1) KC-1000 970mbh 834mbh-902mbh 1’10” 4’9” 6’8” 1200lbs.Two(2) KC-1000-2 1940mbh 1668mbh-1804mbh 5’10” 4’9” 6’8” 2400lbs.

Three(3) KC-1000-3 2910mbh 2503mbh-2706mbh 9’8” 4’9” 6’8” 3600lbs.Four(4) KC-1000-4 3880mbh 3337mbh-3608mbh 13’6” 4’9” 6’8” 4800lbs.Five(5) KC-1000-5 4850mbh 4171mbh-4511mbh 17’4” 4’9” 6’8” 6000lbs.Six(6) KC-1000-6 5820mbh 5005mbh-5413mbh 21’2” 4’9” 6’8” 7200lbs.

Seven(7) KC-1000-7 6790mbh 5839mbh-6315mbh 25’ 4’9” 6’8” 8400lbs.Eight(8) KC-1000-8 7760mbh 6674mbh-7217mbh 28’10” 4’9” 6’8” 9600lbs.

Dimensions KC-1000 Boiler