ad-series electronic locks - access hardware supply · • fips 201 (federal information processing...
TRANSCRIPT
AD-Series Electronic Locks with FIPS201 Compliant Multi-
Technology ReadersFebruary 2011
2 www.schlage.com/ad-series
• FIPS 201 (Federal Information Processing Standards
Publication 201) is a 2006 publication that defines the
Personal Identity Verification (PIV) of federal
employees and contractors.
• In August of 2004 the Homeland Security Presidential
Directive 12 (HSPD 12) was issued to standardize
federal security measures.
• In response to HSPD-12, FIPS 201 was developed to
define the technical requirements for identification and
authentication of Federal employees and contractors
for access to Federal facilities and information
systems with a PIV smart card.
• Mandates the type of Smart Card and Card Reader
per application
FIPS 201 Overview
3 www.schlage.com/ad-series
AD-Series meets FIPS 201
• Two FIPS 201 compliant options are available in the AD-Series;
AD-301 Hardwired and AD-401 Wireless
• The AD-301 and AD-401 meet the following criteria to achieve
FIPS 201 certification:
– Sold and installed as a complete system from the factory with
specific FIPS201 Compliant components including the lock, panel
interface and reader (see subsequent slides for specifics)
– A specific Wiegand communication to the access control panel
(ACP)
– Read PIV/PIV-ll Compliant Smart Cards via FMK Reader
– Maintain specific hardware and firmware versions from the factory
per certification
• The AD-Series cannot be upgraded in the field to achieve FIPS
201 compliance
4 www.schlage.com/ad-series
• Ingersoll Rand is listed on the
IDmanagement website
– http://www.idmanagement.gov/
• FIPS 201 Evaluation Program
Approved Products List
– http://fips201ep.cio.gov/apl.php
– Please refer to Line #’s 533 & 534
Where to Find Listings for AD-301 and AD-401
5 www.schlage.com/ad-series
AD-Series
System Info for
FIPS201
6 www.schlage.com/ad-serieswww.schlage.com/ad-series
AD-401 System Configuration
Wireless Networked: 900 MHz, Secure
encrypted data
transmission. Wiegand
via PIM401-TD2.
AD-401
FMK - FIPS 201/PIV II
Compliant Multi-
Technology Reader:Reads both 13.56 MHz smart
cards & 125 kHz proximity cards.
Compatible with FIPS 201/PIV II (field
configurable to 75 or 200 bit PIV-ll
card), Schlage, XceedID™,
aptiQ™smart cards using MIFARE
DESFire™EV1 with PACSA . Compatible with other brands, see datasheet for complete details
PIM401-TD2:Required for communication
between the AD-401 wireless
integrated lock and the access
control panel. Can support up to 2
AD-401 devices depending on your
access control panel.
Exclusively 70 Function:Classroom/Storeroom
7 www.schlage.com/ad-series
AD-401 Factory Orderable Options
Required
Information above reflects limited options on chassis, function and readers
8 www.schlage.com/ad-serieswww.schlage.com/ad-series
AD-301 System Configuration
Hardwired Networked: Wiegand communication via
PIB301-2D.
AD-301
PIB301-2D:Required for communication
between the AD-301 hardwired
integrated lock and the access
control panel. Can support up to 2
AD-301 locks depending on your
access control panel.
Exclusively 70 Function:Classroom/Storeroom
FMK - FIPS 201/PIV II
Compliant Multi-
Technology Reader:Reads both 13.56 MHz smart
cards & 125 kHz proximity cards.
Compatible with FIPS 201/PIV II (field
configurable to 75 or 200 bit PIV-ll
card), Schlage, XceedID™,
aptiQ™smart cards using MIFARE
DESFire™EV1 with PACSA . Compatible with other brands, see datasheet for complete details
9 www.schlage.com/ad-series
AD-301 Factory Orderable Options
Required
Information above reflects limited options on chassis, function and readers
10
AD-Series Feature Set
AD-401 with
PIM401-TD2
AD-301 with
PIB301-2D
11 www.schlage.com/ad-series
AD-301 & AD-401
Common
Mechanical Options
12 www.schlage.com/ad-series
Chassis
Matching Exit trim is compatible with Von Duprin 98/99 with low
current Request-To-Exit switch (LC/RX)
CY MSCylindrical Mortise 993 Exit Trim
13 www.schlage.com/ad-series
AD-Series Finish Options
14
Lever
Rhodes (RHO) Sparta (SPA)
Tubular (TLR)Athens (ATH)
Note: Standard Core shown; SFIC and FSIC cores also available. Compatible with most major brands, see
appendix.
www.schlage.com/ad-series
15
Lever Cylinder Type
Keyway Type
Handing
Battery
Backset and Latch
Strike
Door Thickness
Other Factory Orderable Options
www.schlage.com/ad-series
• A variety of additional factory orderable
options are available to meet your needs
• See the price book for more information
about available options.
16
AD-Series Field Configurable Options
• PIV-ll Card Format
• Communication Failure Mode
• Power Failure Mode
• Wireless Wake-up On Radio
• Audio FeedbackHandheld Programming
Device (HHD)
www.schlage.com/ad-series
17 www.schlage.com/ad-series
IRHHConnects to
IRHH
Connects to
USB
Proprietary connection
PC for
ActiveSync
Data transfers
Locks for
access
programming
OR
HH-USB
www.schlage.com/ad-series
Handheld Device
18 www.schlage.com/ad-series
AD-Series
Resources & Support
19 www.schlage.com/ad-series
Achieved for Production
• UL 294
• UL 10 C
• BHMA/ANSI 156.25 Grade 1 Operation and Security
• A156.2
• A156.3
• A156.12
• A156.13
• NFPA 101 – Ch 7
• NFPA 80 – Ch 6 & 7
• IBC – Ch 10
• ADA – Ch4.13
• FCC Part 15
• Industry Canada (IC) RSS-210
• FIPS 201 (AD-301 & AD-401)
• Florida Building Code
• RoHS
• Windstorm TAS 201, 202, and 203 for Miami-Dade County
• California Title 24
Scheduled to obtain in 2011
• CE Mark
• IEC/CISPR 22 (2003)
• IEC 61000-4-2 (2001)
• IEC 61000-4-3 (2002)
www.schlage.com/ad-series
AD-Series Codes and Certification
20
AD-Series FIPS201 Solution Datasheets
www.schlage.com/ad-series
ES-5947 ES-5948
21 www.schlage.com/ad-series
E-Learning #1
“Today Meets Tomorrow”
E-Learning #2
“Explore the Details”
E-Learning #3
“Make The Case”
AD-Series Online Training
www.schlage.com/ad-series
Access from AD-Series website: www.schlage.com/ad-series
How to Videos
Available on YouTube and on the AD
website for download to the HHD
Note: Training Courses are not specific to FIPS201 Offering