  • Operating instructions ClassicLine module

    AC5203 / AC5205 AC5208 / AC5211AC5213 / AC5214AC5215 / AC5224

    AC5294

    7390

    951/

    00

    08/2

    012

    UK

  • 2Contents1 Preliminary note 32 Safety instructions 33 Functions and features 34 Installation45 Operating and display elements 96 Addressing 9

    61 Addressing with the AC1154 addressing unit97 Electrical connection 148 Operation 159 Technical data 15

  • 3UK

    1 Preliminary note Aninstructionisindicatedby:

    Example:Mounttheunitasshown. Areactiontotheactionisindicatedby>:

    Example:>yellowLEDlights.

    Important note Non-compliance can result in malfunction or interference

    Information Supplementary note

    2 Safety instructions Please read the operating instructions prior to set-up of the device Ensure that

    the product is suitable for your application without any restrictions The unit conforms to the relevant regulations and EC directives Improper or non-intended use may lead to malfunctions of the unit or to

    unwanted effects in your application Installation, electrical connection, set-up, operation and maintenance of the

    unit must only be carried out by qualified personnel authorised by the machine operator

    3 Functions and features maximumnumberofmodulespermaster:

    - 31 (AC5205, AC5208, AC5211, AC5213) - 62 (AC5203, AC5214, AC5215, AC5224, AC5294)

    AS-interface version 30, downward compatible

  • 44 Installation Disconnectthesystemfrompowerbeforeinstallation.

    1 Alignment of the flat cable on deliveryCarefully place the yellow and optio-nally the black AS-i flat cable into the profile slot

    2 Mounttheupperpart.

    3 Lock the unit

  • 5UK

    With the supplied lower part the flat cable can be aligned in three direc-tionsFor the requested direction place the flat cable guide (1) accordingly

  • 6A Settings at the lower partSelect the position 1, 2 or 3 depending on the requested flat cable alignment ().A = factory setting

    B

    C

  • 7UK

    Settings at the upper partThen set the selected position at the upper part To do so, turn the triangle tothecorrespondingnumber(fig.D1andD2).

    D1 Use a tool, eg a screwdriver (figure D1)ortheyellow/blackflatcableguide(figureD2).

    D2

  • 8Open the unitOpen the unit using a tool as shown (eg screwdriver)

    Take care in laying the AS-i flat cable, the flat cable should be laid straight for about 15 cm

  • 9UK

    5 Operating and display elements

    1

    2

    3

    4

    56

    7

    1: addressing interface2: LEDAUX3: 4M12sockets4: LED25: LED16: labels7: LEDPWR

    6 AddressingThe address is set to 0 at the factory

    6.1 Addressing with the AC1154 addressing unitWhen mounted and wired the module can be addressed with the addressing cable (E70213) via the integrated addressing interfaceIf a slave with the extended addressing mode (AC5203, AC5214, AC5215, AC5224, AC5294) is used in combination with a master of the first generation (version2.0),theparameterP3mustbe1andtheoutputbitD3mustbe0*.TheoutputbitD3andtheparameterbitP3mustnotbeused. **defaultsettingIf a slave with the extended addressing mode is used in combination with a master of the first generation (version 20), an address between 1A and 31A must be assigned to this slave

  • 10

    AC52033 outputs AS-iprofileS-8.A.E/extendedaddressingmode:yes

    Data bit D0 D1 D2 D3Output 1 2 3 -Socket O-1/2 O-1/2 O-2 O-3 -

    Y-circuit outputs

    AC52054 inputs AS-iprofileS-0.0.E/extendedaddressingmode:no

    Data bit D0 D1 D2 D3Input I1 I2 I3 I4Socket I-1 I-2 I-3 I-4

    Inputs

  • 11

    UK

    AC52084 outputs AS-iprofileS-8.0.E/extendedaddressingmode:no

    Data bit D0 D1 D2 D3Output O1 O2 O3 O4Socket O-1/2 O-1/2 O-2 O-3/4 O-3/4 O-4

    Y-circuit outputs

    AC52112 inputs / 2 outputs (2 Ampre)AS-iprofileS-3.0.E/extendedaddressingmode:no

    Data bit D0 D1 D2 D3Input I1 I2 - -Socket I-1 I-2 - -

    Output - - O3 O4Socket - - O-3/4 O-3/4 O-4

    Inputs Y-circuit outputs

  • 12

    AC52134 outputs (2 Ampre)AS-iprofileS-8.0.E/extendedaddressingmode:no

    Data bit D0 D1 D2 D3Output O1 O2 O3 O4Socket O-1/2 O-1/2 O-2 O-3/4 O-3/4 O-4

    Y-circuit outputs

    AC52142 outputs / 2 inputsAS-iprofileS-B.A.E/extendedaddressingmode:yes

    Data bit D0 D1 D2 D3Input - - I3 I4Socket - - I-3/4 I-3/4 I-4

    Output O1 O2 - -Socket O-1/2 O-1/2 O-2 - -

    Y-circuit inputs Y-circuit outputs

  • 13

    UK

    AC52154 inputs AS-iprofileS-0.A.E/extendedaddressingmode:yes

    Data bit D0 D1 D2 D3Input I1 I2 I3 I4Socket I-1/2 I-1/2 I-2 I-3/4 I-3/4 I-4

    Y-circuit inputs

    AC52242 outputs (outputs supplied from AS-i) / 2 inputsAS-iprofileS-B.A.E/extendedaddressingmode:yes

    Data bit D0 D1 D2 D3Input - - I3 I4Socket - - I-3/4 I-3/4 I-4

    Output O1 O2 - -Socket O-1/2 O-1/2 O-2 - -

    Y-circuit inputs Y-circuit outputs

  • 14

    AC52944 inputs AS-iprofileS-0.A.E/extendedaddressingmode:yes

    Data bit D0 D1 D2 D3Input I1 I2 I3 I4Socket I-1 I-2 I-3 I-4

    Inputs

    7 Electrical connectionThe unit must be connected by a qualified electricianThe national and international regulations for the installation of electrical equipment must be adhered to

    Disconnectpower. Connect the unit

    Connecttheplugsofthesensors/actuatorstotheM12sockets,tighteningtorque0.6...0.8Nm.Covertheunusedsocketswithprotectivecaps(E73004)*,the addressing socket with the supplied protective cap Tightening torque 0608 NmTo guarantee protection rating IP 67 you also have to usetheflatcableendseal(E70413)*ifthemoduleisattheendofthecable

    line *tobeorderedseparately

  • 15

    UK

    8 OperationAvoid build-up of dirt and dust on the upper and lower parts so that the locking mechanism is not affected

    LED2yellow: input / output switched LEDPWRgreen: AS-i voltage supply ok LEDAUXgreen: AUXvoltagesupplyok(AC5203,AC5208,

    AC5211, AC5213, AC5214) LEDFAULTredlights: AS-i communication error, slave does not par-

    ticipateinthenormalexchangeofdata,e.g.slave address 0

    LEDFAULTredflashes: peripheral fault, eg sensor supply / output overloaded or shorted

    LED1yellow: logic state of the outputs

    Overload and short circuit of the input supply and the outputs are signalled as peripheral fault to the AS-i master (version 21 or higher)

    9 Technical dataTechnical data and further information at wwwifmcom