Complete product specifications and options can be viewed or downloaded from www.abbinfozone.com The 10DX3111E/A flanged sensors and 50XM1000 transmitters are pulsed DC magnetic flowmeters. These systems are recommended for industrial applications of clean liquids, dirty liquids, clean or dirty liquids with entrained air, low noise producing slurries, and fluids that produce coatings (sludges and pastes). Sizes 1/2 to 12 in. (10DX3111E); 14 in. to 24 in. (10DX3111A) Transmitter 50XM1000 Pressure up to 740 psi @ 100F (see full specifications for more information) ANSI Class 150 (all sizes) and Class 300 (1/2 to 12 in.) flanges Process Up to 356 F (max limit varies with Temperature liner selection) Liner Hard or soft rubber (2 to 24 in.); Polyurethane (2 to 24 in.); Neoprene (2 to 24 in.); PTFE (1/2 to 24 in.); Tefzel (1/2 to 12 in.); Linatex (2 to 24 in.) Electrodes Flush, bullet nose or slurry type in 316 stainless steel; Hastelloy C; Hastelloy B; Titanium; Tantalum; Platinum-Iridium; Zirconium Sensor Housing Cast Aluminum Sensor NEMA 4X (IP 65) General Purpose. Classification Options for FM Approved for Class I, Division 2, Groups A to D and for Class I, Division 1, Groups B to D (See full Specifications for more information) Transmitter NEMA 4X (IP 65) General Purpose. Classification Option for FM Approved Non-ince- dive for Class I, Division 2, Groups A to D (See full Specifications for more information) System 0.5% standard; 0.25% optional Accuracy (0.67 to 49 fps) Conductivity Greater than 5µS/cm Excitation Pulsed DC with multiple coil drive frequency options Abridged Specifications: 10DX3111E/A Sensor with 50XM1000 Transmitter Communications HART, RS-485, or RS-232 options Mounting Field mounted Transmitter Power: 24 V dc, 110/115/120 V ac (50/60 Hz), 220/230/240 V ac (50/60 Hz) Features/ Accidental sensor submergence (IP 67) Options Continuous sensor submergence (IP 68) Analog output Scaled or unscaled frequency output Dual range Contact Input/output Empty pipe detection Bi-directional flow measurement Full Diagnostics Illuminated 2-line LCD display PTFE liner protector plate Variable lay lengths

Upload: truongkhuong

Post on 23-Apr-2018

231 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Abridged Specifications: 10DX3111E/A Sensor with … Specifications: 10DX3111E/A Sensor with 50XM1000 Transmitter Communications HART, RS-485, or RS-232 options Mounting Field mounted

Complete product specifications and options can be viewed or downloaded from www.abbinfozone.com

The 10DX3111E/A flanged sensors and 50XM1000 transmitters are pulsed DC magnetic flowmeters. These systems are recommended for industrial applications of clean liquids, dirty liquids, clean or dirty liquids with entrained air, low noise producing slurries, and fluids that produce coatings (sludges and pastes).

Sizes 1/2 to 12 in. (10DX3111E); 14 in. to 24 in. (10DX3111A)

Transmitter 50XM1000

Pressure up to 740 psi @ 100F (see full specifications for more information) ANSI Class 150 (all sizes) and Class 300 (1/2 to 12 in.) flanges

Process Up to 356 F (max limit varies with Temperature liner selection)

Liner Hard or soft rubber (2 to 24 in.); Polyurethane (2 to 24 in.); Neoprene (2 to 24 in.); PTFE (1/2 to 24 in.); Tefzel (1/2 to 12 in.); Linatex (2 to 24 in.)

Electrodes Flush, bullet nose or slurry type in 316 stainless steel; Hastelloy C; Hastelloy B; Titanium; Tantalum; Platinum-Iridium; Zirconium

Sensor Housing Cast Aluminum

Sensor NEMA 4X (IP 65) General Purpose. Classification Options for FM Approved for Class I, Division 2, Groups A to D and for Class I, Division 1, Groups B to D (See full Specifications for more information)

Transmitter NEMA 4X (IP 65) General Purpose. Classification Option for FM Approved Non-ince- dive for Class I, Division 2, Groups A to D (See full Specifications for more information)

System 0.5% standard; 0.25% optional Accuracy (0.67 to 49 fps)

Conductivity Greater than 5µS/cm

Excitation Pulsed DC with multiple coil drive frequency options

Abridged Specifications:

10DX3111E/A Sensor with 50XM1000 Transmitter

Communications HART, RS-485, or RS-232 options

Mounting Field mounted

Transmitter Power: 24 V dc, 110/115/120 V ac (50/60 Hz), 220/230/240 V ac (50/60 Hz)

Features/ Accidental sensor submergence (IP 67) Options Continuous sensor submergence (IP 68) Analog output Scaled or unscaled frequency output Dual range Contact Input/output Empty pipe detection Bi-directional flow measurement Full Diagnostics Illuminated 2-line LCD display PTFE liner protector plate Variable lay lengths

Page 2: Abridged Specifications: 10DX3111E/A Sensor with … Specifications: 10DX3111E/A Sensor with 50XM1000 Transmitter Communications HART, RS-485, or RS-232 options Mounting Field mounted

10DX3111E/A

10DX3111 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Design Level (For Use w/Remote Converter 50XM1000) 50XM1000N Converter (0.5 - 12") ............................. E 50XM1000N Converter (14 - 24") .............................. A

Meter Lay Length Short Form (W-Mag), Standard (0.5" to 12" only) .........D Match 10D1419 or 10D1465 F-F ....................................E ²Match 10D1435 F-F ....................................................F Liner Hard Rubber ........................................................................ A tSoft, Natural Rubber ............................................................ B Polyurethane........................................................................ D sPTFE Teflon .......................................................................... E Neoprene ............................................................................. L zTefzel.................................................................................... N Linatex.................................................................................. P

Size n15mm (1/2") ........................................................................07 n25mm (1") ...........................................................................09 n40mm (1-1/2") ....................................................................11 50mm (2") ...........................................................................12 80mm (3) ............................................................................14 100mm (4") ...........................................................................15 150mm (6") ...........................................................................17 200mm (8") ...........................................................................18 250mm (10") .........................................................................19 300mm (12”) .........................................................................20 350mm (14")..........................................................................21 400mm (16")..........................................................................22 450mm (18")..........................................................................35 500mm (20")..........................................................................23 600mm (24")..........................................................................24

s Not available in continuous submersible enclosure² 12-inch size only. Select Polyurethane or Neoprene liner.n Teflon or Tefzel liner only; Tefzel liner only available with Meter Lay Length D.Æ Customer electrical connection box has PG 13.5 cable seal connections.v Customer electrical connection box has 1/2" NPT for conduit connections.z Tefzel liner only available with meter lay length D.

Page 3: Abridged Specifications: 10DX3111E/A Sensor with … Specifications: 10DX3111E/A Sensor with 50XM1000 Transmitter Communications HART, RS-485, or RS-232 options Mounting Field mounted

10DX3111E/A

10DX3111 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Flange Standard & Pressure Rating vANSI Class 150 .......................................................P vANSI Class 300 .......................................................Q

Flange Material Carbon Steel, Standard ..................................... 1 304 Stainless Steel (150 Class Only) ..................... 2

nProtector Plate None Required.............................................................. A 316 Stl.St ................................................................. B Hastelloy C ................................................................. E Electrode Design Flush .....................................................................................2 ÆBullet Nose............................................................................3 vSlurry Service........................................................................7 Electrode Material 316 Stainless Steel ......................................................................B Hastelloy B...................................................................................C Hastelloy C...................................................................................D Titanium .......................................................................................E tTantalum ......................................................................................F tPlatinum/Iridium (14" ≥ Consult Factory)....................................H Zirconium .....................................................................................L

n Teflon liner only; serves as grounding ring.Æ 2" and larger sizes only. Electrode material must be 316 stainless steel.t Teflon or Tefzel Liner only.v Electrode material must be stainless steel and liner material must be Polyurethane, Neoprene, or Rubber, ≥ 14" only² See Product Specification 10DX3111 for more details on certification.

Page 4: Abridged Specifications: 10DX3111E/A Sensor with … Specifications: 10DX3111E/A Sensor with 50XM1000 Transmitter Communications HART, RS-485, or RS-232 options Mounting Field mounted

10DX3111E/A

10DX3111 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

²Certification General Purpose..................................................................... A FM Approved Cl I, Div. 2, Gps. A,B,C&D Standard ........... K Explosion Proof, FM Cl I, Div. 1, Gps B,C & D (0.5" - 12" only)... L

Enclosure Classification (For Liner Selection) IEC 529 IP 65, NEMA 4X.............................................................1S IEC 529 IP 67, Accidental Submergence in water to 33 ft for 48 hrs ......................................................................2l IEC 529 IP 68, Continuous Submergence in water to 33 ft ......5l IEC 529 IP 67, Accidental Submergence to 33 ft for 48 hrs and Potted Terminal Box (Level 9 Protection) .............9

Process Temperature Range Teflon and Tefzel; Standard up to 266°F (130°C)............................. 1 Teflon only; extended temp. up to 356°F (180°C) (0.5"-12" only)..... 2 Hard and Soft Rubber up to 176°F (80°C) ........................................ 3 Polyurethane & Neoprene up to 190°F (88°C) .................................. 4p Teflon PTFE <302ºF (150ºC) ....................................................................5

Coil Drive Frequency (Line Frequency) 6-1/4 Hz (50 Hz) ........................................................................................ 1 12-1/2 Hz (50 Hz) ...................................................................................... 2 7-12/ Hz (60 Hz), Standard .................................................................... 3 15 Hz (60 Hz) ............................................................................................. 4

Customer Information Language English w/riveted SST tag................................................................................ 2≥ English w/self adhesive tag ............................................................................. 8

Remote Converter Type Specified .................................................................................................................1 Not specified...........................................................................................................X

Permanently Installed Signal Cable Æ For Enclosure Classification 5 & 9 Only Cable Length 50 Feet ..................................................................................................05 Cable Length 100 Feet ................................................................................................10 Not Required................................................................................................................XX

S Standard cable length is 30 ft unless longer length is specified up to maximum of 250 ft. Consult factory for lengths over 250 feet.Æ Longer lengths can be specified at time of order. Add $2.50 per foot for lengths over 50 feet. Level 5 not available with Teflon liner material. l Cable is permanently attached and the length must be specified at time of order under "Permanently Installed Signal Cable" character.≥ Not available with continuous submergence enclosure Class 5.p Not available with IP68 continuous submergence

Page 5: Abridged Specifications: 10DX3111E/A Sensor with … Specifications: 10DX3111E/A Sensor with 50XM1000 Transmitter Communications HART, RS-485, or RS-232 options Mounting Field mounted

50XM1000N

50XM1 _ _ _ _ _ _ _ _ _ _ _ _ _ ♥Drive Frequency 6-1/4 Hz (50 Hz) ..................................1 12-1/2 Hz (50 Hz) ................................2 7-1/2 Hz (60 Hz), Standard ...............3 15 Hz (60 Hz) .......................................4 6-1/4 Hz (DC Power)...........................5 12-1/2 Hz (DC Power..........................6 7-1/2 Hz (DC Power)...........................7 15 Hz (DC Power) ...............................8

Design Level ................................................. N

Software Level ..................................................... X

Certifications General Purpose..................................................... A FM Approved Non-Incendive Cl I, Div. 2, Gps A, B, C, & D Standard ............ K

♣Enclosure NEMA 4X Field Housing w/PG 13.5 Connections........B NEMA 4X Field Housing w/ 1/2" NPT Connections, Standard ...........................................D

Contact Ouputs Optocoupler, Standard ......................................................1 Relay .....................................................................................2

Output Options Without.........................................................................................0 lActive Scaled Pusle, Fwd & Rev. ................................................1 Relay Contact Scaled Pulse Fwd & Rev.....................................2 lOpto-coupled Scaled Pulse Fwd & Rev......................................3 RS 485 Port..................................................................................4 RS 232C Port ...............................................................................5ulRS 485 Port & Pulse Output Opto Fwd ......................................6ulRS 232C Port & Pulse Output Opto Fwd....................................7 uRS 485 Port w/Relay Pulse Output Fwd ....................................8

♥ Frequency selected above should be the same as the freq. selected on the magmeter

♣ [B] Cable seal is used with Din flange primary. [D] 1/2 NPT is used with ANSI flange primaryl 4 KHz max. pulse. Width configurable from 0.1ms to 2000ms.u Alarm contact not available with this option.

Page 6: Abridged Specifications: 10DX3111E/A Sensor with … Specifications: 10DX3111E/A Sensor with 50XM1000 Transmitter Communications HART, RS-485, or RS-232 options Mounting Field mounted

50XM1000N

50XM1 _ _ _ _ _ _ _ _ _ _ _ _ _ Operation Mode Continuous Measurement...................................... AA Additional Options Without...........................................................................B nHART Protocol................................................................H

Electrical Requirements 220/230/240 V, 50/60 Hz ......................................................A 110/115/120 V, 50/60 Hz ......................................................C 24 Vdc ...................................................................................H

Customer Language English..........................................................................................2 Output Current 0-20 mA.............................................................................................. 1 4-20 mA, Standard ......................................................................... 2

♠Primary Model Number Continuous Submergence 14 - 24 only ................................................... 8 10DX.......................................................................................................... 9

n Not available with RS232C or RS485.

♠ Option 8 above is only for meter sizes 14" - 24" with continuous submergence. Other sizes w/cont. subm. select by primary type.