aa-0380a- acc20 b&w me instruction manual

110
Instruction manual AutoChief ® C20 AA-00380-A i AutoChief C20 Instruction Manual MAN B&W ME Engines Fixed Propeller installation

Upload: andy-ganea

Post on 10-Nov-2015

727 views

Category:

Documents


161 download

DESCRIPTION

auto chief manual

TRANSCRIPT

  • Instruction manual AutoChief C20

    AA-00380-A i

    AutoChief C20

    Instruction Manual

    MAN B&W ME Engines

    Fixed Propeller installation

  • Instruction manual AutoChief C20

    ii AA-00380-A

  • Instruction manual AutoChief C20

    AA-00380-A iii

    Revisions

    Written by Checked by Approved by Rev. Date Sign. Date Sign. Date Sign.

    A 06.10.2004 T 06.10.2004 SM 06.10.2004 SM B C D

    Document history

    Issue No. ECO No. Paragraph No. Paragraph Heading / Description of change

    A First Issue

    The information contained in this document is subject to change without prior notice. Kongsberg Maritime AS shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this document. 2004 Kongsberg Maritime AS. All rights reserved. No part of this work covered by the copyright hereon may be reproduced or otherwise copied without prior permission from Kongsberg Maritime AS.

    Bekkajordet P.O.Box 1009N-3194 Horten,Norway

    Kongsberg Maritime AS

    Telephone: +47 33 03 20 00Telefax: +47 85 02 80 28www.kongsberg.com

  • Instruction manual AutoChief C20

    iv AA-00380-A

    Table of contents

    1 INTRODUCTION ............................................................................................................................1

    2 FUNCTIONAL DESCRIPTION.....................................................................................................2

    2.1 REMOTE CONTROL SYSTEM FUNCTIONAL DESCRIPTION............................................................2 2.2 AUTOCHIEF CONTROL PANEL (ACP)......................................................................................5

    2.2.1 LCD Display.........................................................................................................................6 2.2.2 Cancel functions ...................................................................................................................6 2.2.3 Alarm Acknowledge and in command functions...................................................................7 2.2.4 Multifunctional knob.............................................................................................................7

    2.3 AUTOCHIEF COMBINED LEVER AND TELEGRAPH UNIT (LTU) ................................................8 2.3.1 Emergency Stop ....................................................................................................................8 2.3.2 Command Transfer functions ...............................................................................................9 2.3.3 Sub-Telegraph functions.....................................................................................................10 2.3.4 Lever function.....................................................................................................................11

    2.4 AUTOCHIEF BRIDGE WING CONTROL UNIT BWU..................................................................12 2.4.1 Emergency Stop ..................................................................................................................12 2.4.2 Transfer functions...............................................................................................................13 2.4.3 Safety functions...................................................................................................................14 2.4.4 Lever function.....................................................................................................................15 2.4.5 Indicators............................................................................................................................15 2.4.6 Panel Dimming...................................................................................................................16

    2.5 AUTOCHIEF PUSH-BUTTON TELEGRAPH (PBT) ....................................................................17 2.5.1 Command Transfer functions .............................................................................................18 2.5.2 Sub-Telegraph functions.....................................................................................................19

    2.6 SAFETY SWITCH PANEL ............................................................................................................20 2.6.1 Safety functions...................................................................................................................20

    2.7 PBT IN CABINET FOR ME ENGINE ............................................................................................22 2.7.1 function and indicators.......................................................................................................22

    2.8 DISTRIBUTED PROCESSING UNITS .............................................................................................23 2.8.1 General ...............................................................................................................................23 2.8.2 Dual Process Segment Controller (dPSC)..........................................................................25 2.8.3 RPMD Unit (RPMD) ..........................................................................................................26 2.8.4 Remote Analogue Input (RAi-16)........................................................................................27 2.8.5 Remote Analogue Input (RAi-10tc).....................................................................................28 2.8.6 Remote Digital Input (RDi-32 and RDi-32a)......................................................................29 2.8.7 Remote Analogue Output (RAo-8) ......................................................................................29 2.8.8 Remote Digital Output (RDo-16)........................................................................................30 2.8.9 Process Segment Starcoupler (PSS) ...................................................................................30

    2.9 REMOTE CONTROL SYSTEM FUNCTIONS ...................................................................................31 2.9.1 Start fail/block ....................................................................................................................31

    2.9.1.1 Start failed............................................................................................................................... 31 2.9.1.2 Start air pressure low............................................................................................................... 31

  • Instruction manual AutoChief C20

    AA-00380-A v

    2.9.1.3 Engine tripped ......................................................................................................................... 31 2.9.1.4 Start blocked ........................................................................................................................... 31 2.9.1.5 Engine blocked........................................................................................................................ 31

    2.9.2 Engine state ECS ................................................................................................................31 2.9.2.1 Start air distributor blocked..................................................................................................... 31 2.9.2.2 Main Start air valve blocked ................................................................................................... 31 2.9.2.3 Turning gear engaged.............................................................................................................. 31 2.9.2.4 Control air vented.................................................................................................................... 31 2.9.2.5 Engine not ready/ready............................................................................................................ 31

    2.9.3 Starting the main engine.....................................................................................................31 2.9.3.1 Prepare Start. ........................................................................................................................... 31 2.9.3.2 Starting.................................................................................................................................... 31 2.9.3.3 Repeated start .......................................................................................................................... 31 2.9.3.4 Running................................................................................................................................... 31

    2.9.4 RPM limiters.......................................................................................................................31 2.9.4.1 Load Limitation....................................................................................................................... 31 2.9.4.2 Slow Down.............................................................................................................................. 31

    2.9.5 Operation modes ................................................................................................................31 2.9.5.1 Emission mode........................................................................................................................ 31 2.9.5.2 Economy mode ....................................................................................................................... 31

    2.9.6 Reversing the main engine..................................................................................................31 2.9.7 Stopping the main engine ...................................................................................................31

    2.10 SAFETY SYSTEM FUNCTIONS ....................................................................................................31 2.10.1 Safety function Shut down..............................................................................................31

    2.10.1.1 Shut Down Function (1 6) .................................................................................................... 31 2.10.1.2 Cancellable Shut Down........................................................................................................... 31 2.10.1.3 Emergency Stop function ........................................................................................................ 31 2.10.1.4 Over-speed Shut Down ........................................................................................................... 31

    2.10.2 Safety function Slow Down ............................................................................................31 2.10.2.1 Slow Down Function (1 20) ................................................................................................. 31 2.10.2.2 Cancellable Slow Down.......................................................................................................... 31

    2.11 RPM MEASUREMENT FUNCTIONS.............................................................................................31 2.11.1 Dual engine speed detector system for MAN B&W ME Engines...................................31 2.11.2 RPM detector failure .....................................................................................................31

    3 OPERATING INFORMATION....................................................................................................31

    3.1 INTRODUCTION ........................................................................................................................31 3.2 AUTOCHIEF CONTROL PANEL (ACP)....................................................................................31

    3.2.1 General operation from bridge...........................................................................................31 3.2.1.1 Preparing engine for start in ECR ........................................................................................... 31 3.2.1.2 Transfer control from ECR to Bridge...................................................................................... 31 3.2.1.3 Start Auxilliary blowers .......................................................................................................... 31 3.2.1.4 Start engine ahead ................................................................................................................... 31 3.2.1.5 Stop engine.............................................................................................................................. 31 3.2.1.6 Start engine astern ................................................................................................................... 31

    3.2.2 Normal operations from Bridge..........................................................................................31

  • Instruction manual AutoChief C20

    vi AA-00380-A

    3.2.2.1 Cancel SHD............................................................................................................................. 31 3.2.2.2 Cancel SLD............................................................................................................................. 31 3.2.2.3 Cancel Limits .......................................................................................................................... 31 3.2.2.4 Sound off................................................................................................................................. 31 3.2.2.5 Alarm ack................................................................................................................................ 31

    3.2.3 General Operation from the bridge Wing...........................................................................31 3.2.3.1 Transfer from bridge to bridge wing ....................................................................................... 31 3.2.3.2 Manoeuvring from the bridge wing......................................................................................... 31 3.2.3.3 Transfer from Bridge Wing to Bridge ..................................................................................... 31

    3.2.4 General operation from ECR..............................................................................................31 3.2.4.1 Transfer control from bridge to ECR ...................................................................................... 31 3.2.4.2 Start engine ahead ................................................................................................................... 31

    3.2.5 Normal operations from ECR.............................................................................................31 3.2.5.1 Cancel SHD from ACP ........................................................................................................... 31 3.2.5.2 Cancel SLD from ACP............................................................................................................ 31 3.2.5.3 Cancel Limits from ACP......................................................................................................... 31 3.2.5.4 Sound off................................................................................................................................. 31 3.2.5.5 Cancel Shut Down from SSP .................................................................................................. 31 3.2.5.6 Cancel Slow Down from SSP ................................................................................................. 31 3.2.5.7 Cancel Limiter from SSP ........................................................................................................ 31 3.2.5.8 Stop engine.............................................................................................................................. 31 3.2.5.9 Start engine astern ................................................................................................................... 31

    3.2.6 General operation from Local Stand, ME Engine ..............................................................31 3.2.6.1 Transfer control from ECR to Local stand .............................................................................. 31 3.2.6.2 Start engine ahead from Local Stand....................................................................................... 31 3.2.6.3 Cancel Shut down from local stand......................................................................................... 31 3.2.6.4 Stop engine from Local Stand ................................................................................................. 31 3.2.6.5 Start engine astern from Local Stand ...................................................................................... 31

    3.3 ADVANCED OPERATION BRIDGE AND ECR. .............................................................................31 3.3.1.1 Guide to the Graphic pages ..................................................................................................... 31 3.3.1.2 Home Display ......................................................................................................................... 31 3.3.1.3 Fine tuning .............................................................................................................................. 31 3.3.1.4 Control position transfer.......................................................................................................... 31 3.3.1.5 Misc. menu.............................................................................................................................. 31 3.3.1.6 Safety System.......................................................................................................................... 31 3.3.1.7 B&W Modes ........................................................................................................................... 31

    4 MAINTENANCE............................................................................................................................31

    4.1 INTRODUCTION ........................................................................................................................31 4.2 OVERVIEW ...............................................................................................................................31 4.3 UNIT REPLACEMENT.................................................................................................................31

    4.3.1 Recommended tools ............................................................................................................31 4.4 PREVENTIVE MAINTENANCE.....................................................................................................31

    4.4.1 General ...............................................................................................................................31 4.4.2 Weekly maintenance ...........................................................................................................31

    4.4.2.1 Distributed Processing Units ................................................................................................... 31

  • Instruction manual AutoChief C20

    AA-00380-A vii

    4.4.3 3-monthly maintenance.......................................................................................................31 4.4.4 6-monthly maintenance.......................................................................................................31 4.4.5 Yearly maintenance ............................................................................................................31

    4.5 TROUBLESHOOTING .................................................................................................................31 4.5.1 Troubleshooting Distributed Processing Units ..................................................................31

    4.5.1.1 How to handle Distributed Processing Units error codes ........................................................ 31 4.5.1.2 How to handle Distributed Processing Units communication errors ....................................... 31

    4.5.2 Additional Troubleshooting for AutoChief Control Panel (ACP),......................................31 4.6 REPLACEMENT OF UNITS .........................................................................................................31

    4.6.1 How to replace the HMI units of the Autochief Propulsion Control System ......................31 4.6.2 How to replace Distributed Processing Units, MEI, DGU, ESU, RPMU ..........................31 4.6.3 How to replace printers......................................................................................................31

    5 AS BUILT CONFIGURATION FROM SEAMATE ..................................................................31

  • Instruction manual AutoChief C20

    AA-00380-A 1

    1 INTRODUCTION This manual is generated through the configuration tool called Seamate. The manual is therefore customised for each system delivery.

    The intention with this manual is to explain the functionality for each mayor component and the total system as its configured for each delivery.

    How to operate the system is described in a manner where we assume that the system is in operation and that normal operations shall be carried out. This manual is not made for advanced troubleshooting.

    The manual contains five chapters

    Introduction Functional Description Operation Maintenance As Built Configuration From Seamate.

  • Instruction manual AutoChief C20

    2 AA-00380-A

    2 FUNCTIONAL DESCRIPTION

    2.1 Remote Control System Functional Description

    The Kongsberg Maritime C20 Marine Automation system consists of, among others the AutoChief C20 Propulsion Control System. Modular design allows flexibility in configuring the system to individual requirements, covering the whole range from standard propulsion configurations to highly advanced twin or quadruple engine installations with high, medium or low speed engines connected to reduction, reversing gear or variable pitch propellers. This system may be a part of a total integrated ship control system consisting of other sub. Systems such as:

    Alarm and monitoring system. Auxiliary control system. Power management system. Ballast automation system. HVAC (air conditioning). Management support The system is based on Kongsberg Maritime unified automation concept, where each individual ship configuration is built up using standard modules communicating on CAN- and local area networks. The C20 system is configurable for all ship types. The AutoChief C20 Propulsion Control System is designed for remote control of the main engine from the combined telegraph and manoeuvring lever in the wheelhouse. By moving this lever, the system will automatically start, reverse, stop and speed-set the main engine.

  • Instruction manual AutoChief C20

    AA-00380-A 3

    BRIDGE

    CONTROL ROOM

    ENGINE ROOM

    PORT WING

    Bridge WingManoeuvring Unit

    Bridge WingManoeuvring Unit

    Bridge Manoeuvring Unit

    STB. WINGOrder Printer

    Control Room Manoeuvring Unit

    Local Control Panelwith Engine Telegraph

    Dual overspeed Lines(Hardwired)

    RPMDetectors

    Em.stop line(Hardwired)

    Dual CAN

    Telegraph Lines

    Dual CAN

    LocalControl Line(Hardwired)

    SSPPanel

    Engine Safety UnitSlow Down

    Engine Safety UnitShut Down

    Hard wired 2x 4-20 mA and 2x stop.

    Dual RPM Units (Includingoverspeed system)

    ASTERN

    AHEAD

    DPU ESU

    EICUA&B

    MAN B&W ME

    ECUA&B

    ASTERN

    AHEAD

  • Instruction manual AutoChief C20

    4 AA-00380-A

    The main components of the AutoChief C20 Propulsion Control System are:

    Control panel Remote control system Engine telegraph system Engine safety system Digital governor system Manoeuvring recorder Distributed processing units AutoChief C20 complies with the requirements of IMO, local maritime authorities, IACS, and eleven classification societies. It is designed to meet the classification societies requirements for periodically unmanned engine room operation. The system conforms to all rules and regulations, and all modules are type approved. The system incorporates the latest advances in hardware and software technology. AutoChiefC20 is developed to strict military QA standards

  • Instruction manual AutoChief C20

    AA-00380-A 5

    2.2 AutoChief Control Panel (ACP)

    CancelSHD

    CancelSLD

    Cancellimits

    Incommand

    Soundoff

    Alarmackn.

    20 bar

    0 rpm

    0 %69 rpm 69 rpm

    Running

    120-120

    -60 60

    0ME RPM START AIR PRESS LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    HOMEEngine StateSafety System

    Misc MenuControl Pos.LimitersAlarms

    At Sea Bridge Eng Ready System Ready

    400

    10 3020

    B&W Modes

    The control panel is designed for ease of operation. An advanced yet simple to use multifunction controller gives access to all system functions. Information is provided only when needed to keep operation simple. A colour display presents key information graphically for easy understanding. Custom designed mimic pictures are available for each engine type, and all main variables such as RPM, consumption, pitch, start air and scavenging air pressure, engine state etc. are always available. The control panel can be installed into any standard console. To distinguish between user groups several levels of control are available.

    functions

    Control position Cancel

    shutdown/slowdown

    Alarm ackn./sound off Changing of parameters General alarm ind.

    Indications

    Analogue RPM and set-point

    Analogue start air pressure Current main engine state Start blockings Shutdown/slowdown Bump-less control transfer

  • Instruction manual AutoChief C20

    6 AA-00380-A

    2.2.1 LCD Display

    20 bar

    0rpm

    0 %69 rpm 69 rpm

    Running

    120-120

    -60 600

    ME RPMStart air pressure low

    400

    10 3020 ACT SETP

    Fuel index50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    HOMEEngine StateSafety System

    Misc MenuControl Pos.LimitersAlarms

    At Sea Bridge Eng Ready

    HOMEEngine StateSafety System

    Misc MenuControl Pos.LimitersAlarms

    Bridge Eng ReadySub Tel Transfer

    Start BlockedReady for StartSlow TurningStartingRepeated Start

    STATE3 Starts failedStart too longSlow turning fail

    START FAIL/BLOCKStart air distributor blockedMain start air valve blockedTurning gear engaged

    ENGINE NOT READY

    Governor disconnectedStart air pressure lowRpm detector failEngine trippedEngine not ready

    RunningCrash AsternStoppingEngine Tripped

    The ACP LCD display is used for the mayor interface between the operator and the system to be monitored. All interaction such as monitoring of starting air pressure, main engines RPM and load, adjustment of operational parameters and displaying of safety related and conventional alarms are carried out with the aids of this display.

    The information is selected from menus via soft-keys. When a menu is chosen a corresponding mimic picture will appear.

    The mimic pictures may consist of textual information, analogue indicators, bar graphs or soft-keys making the operator able to navigate into other related mimics.

    However, functions which require direct access, such as, emergency stop, cancel functions and alarm acknowledge / sound off is accessible via push-buttons on the front of the ACP.

    2.2.2 Cancel functions

    CancelSHD

    CancelSLD

    Cancellimits

    The cancel functions available on the AutoChief control panel are:

    Cancel SHD, only cancellable Shut Downs will respond to this function.

    Cancel SLD, only cancellable Slow Downs will respond to this function.

    Cancel limits, used to cancel RPM, fuel and load limiters which is active in the remote control system.

  • Instruction manual AutoChief C20

    AA-00380-A 7

    2.2.3 Alarm Acknowledge and in command functions

    Incommand

    Soundoff

    Alarmackn.

    The alarm and command functions available on the AutoChief control panel are:

    In Command, indicates with a green LED that the actual ACP is in command

    Sound off, used for silencing buzzer when an alarm is active.

    Alarm Ackn., used for accepting alarm indications. When the alarm condition has returned to normal state the alarm text will disappear from the display

    2.2.4 Multifunctional knob

    The multifunctional knob (Rotary Knob):

    For navigating through mimic pictures and objects in in the mimic pictures.

    To be turned clockwise or counter clockwise, until required field is high-lighted, push the wheel for entering into a new mimic picture or field to be operated.

    Change value, move graphic levers or handles or scroll through roll-up menus, press knob for activating required function.

    The multifunctional knob has no stop in turning either way, it will navigate the operator through available fields in each picture.

  • Instruction manual AutoChief C20

    8 AA-00380-A

    2.3 AutoChief Combined Lever and telegraph unit (LTU)

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    D.Slow AST

    EmergencyStop

    Essentially, an Engine Telegraph System is designed to control the engine and comprises an AutoChiefC20 Lever Telegraph Unit (LTU) at the following locations:

    Bridge Control room

    The AutoChiefC20 Lever Telegraph Unit (LTU) is a combined telegraph & manoeuvring lever with telegraph handle and emergency stop switch

    2.3.1 Emergency Stop

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    D.Slow AST

    EmergencyStop

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    STOP

    The emergency stop button in the bridge console is located in the LTU. At the lower part of the lever, a cover marked with emergency stop can be opened. The emergency stop button is located below this cover The emergency stop function activates the emergency stop system in the main engine safety system. Additionally the conventional stop system is activated and the speed order to the rpm control system is set to zero rpm.

    Functions Push-button pressed once for emergency stop Push-button pressed twice for reset

    Indications The push-button illumination is red. When active the illumination is enhanced. The cover has a translucent section, so if its closed

    the light will show through

  • Instruction manual AutoChief C20

    AA-00380-A 9

    2.3.2 Command Transfer functions

    Bridge

    ECR

    Local

    The command transfer section is used for selecting the location for controlling the main engine Bridge The operator on the bridge is controlling the engine via the automatic Remote Control System. The Engine Telegraph System is disabled. ECR The control room personnel have control of the engine. Communication is established between the bridge and engine control room via the telegraph system Local The engine room personnel have control of the engine from the local control system. Communication is established between the bridge and engine room via the telegraph system.

    Functions Push-button pressed once for request of command Push-button pressed twice for accept of command

    Indications The push-button LED indicator is lit to confirm

    control position The push-button LED indicator is flickering when a

    control position is requested but not accepted.

  • Instruction manual AutoChief C20

    10 AA-00380-A

    2.3.3 Sub-Telegraph functions

    At sea

    Stand by

    FWE

    The sub-telegraph functions are included for informing the engine crew about the subsequent need for propulsive and electric power. At Sea The operator on the bridge is informing that all systems has to be prepared and set-up for seagoing. Stand by The operator on the bridge is informing that all systems has to be prepared for stand by. Engine to be prepared for start. It may also inform the crew that the vessel is entering channel or harbours where special attention has to be made to the machinery or steering plant. FWE ( Finished with engine) The operator on the bridge is informing that there will be no need for propulsive power. The crew will block main start valve and drain the line, Start air distributor will be locked and control air drained. For the MAN B&W engines this lamp will flicker until all actions is made to inhibit the engine to start unintentionally. This function is called FWE Loop abnormal.

    Functions Push-button pressed for request of mode

    Indications The push-button LED indicator is lit to confirm sub-

    telegraph mode

  • Instruction manual AutoChief C20

    AA-00380-A 11

    2.3.4 Lever function

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    SLOW

    EmergencyStop

    SLOW

    SLOW

    The telegraph handle enables an operator on the bridge to be in direct command of the ship by allowing speed and rotation control of the engine. The lever operates in eleven fixed steps, where each step represents an RPM command in ahead or astern direction. The steps are the following: Ahead: D.Slow, Slow, Half, Full, Navigation Full, Stop Astern: D.Slow, Slow, Half, Full, Emergency Astern The lever can be moved between the steps as well for adjusting the rpm level Additionally its possible to use a fine tuning parameter available on the ACP mimic.

    Functions Lever set to required position.

    Indications A corresponding led is lit on each side of the lever. Above the cover for emergency stop button there are

    a digital display which shows textual information, which telegraph position which is selected.

    On each side of the lever there are a digital display which shows textual information and a arrow indicating the direction of rotation

  • Instruction manual AutoChief C20

    12 AA-00380-A

    2.4 AutoChief Bridge wing control unit BWU

    ASTERN AHEAD

    EMERGENCY STOP

    BWU C20BRIDGE WING UNIT

    STOP

    D.SLOW

    SLOW

    HALFFULL

    NAV.FULL

    D.SLOW

    SLOW

    HALF

    FULL

    EM.AST.

    rpm-100

    0

    100

    START AIR PRESSURE

    0

    20

    40

    Transfer functions

    Cancel SHD

    Cancel SLD

    In Command

    Panel dim. -+

    Shut Down

    Slow Down

    Not Cancellable

    CancellableSafety functions

    2.4.1 Emergency Stop

    EMERGENCY STOP

    EMERGENCY STOP

    EMERGENCY STOP

    The emergency stop button in the bridge wing console is located in the BWU C20. At the lower part of the panel, a cover marked with emergency stop can be opened. The emergency stop button is located below this cover The emergency stop function activates the emergency stop system in the main engine safety system. Additionally the conventional stop system is activated and the speed order to the rpm control system is set to zero rpm.

    Functions Push-button pressed once for emergency stop Push-button pressed twice for reset

    Indications The push-button illumination is red. When active the illumination is enhanced. The cover has a translucent section, so if its closed

    the light will show through

  • Instruction manual AutoChief C20

    AA-00380-A 13

    2.4.2 Transfer functions

    Transfer functions

    Cancel SHD

    Cancel SLD

    In Command

    Panel dim. -+

    Shut Down

    Slow Down

    Not Cancellable

    CancellableSafety functions

    In Command

    The command transfer function is solved by functions in the push-button panel at the left side of the BWU (bridge wing unit Port or starboard. Wing control is selected from the ACP in the centre bridge console. When the request is done the indicator lamp In Command on the bridge wing will flicker. The system is equipped with an electric shaft system between the levers, which makes a bump-less transfer possible. The pushbutton In command will, when pressed, transfer the control from bridge to requested bridge wings.

    Functions Push-button pressed once for activation

    Indications The push-button LED indicator is green.

  • Instruction manual AutoChief C20

    14 AA-00380-A

    2.4.3 Safety functions

    Cancel SLD

    Cancel SHD

    The Safety functions in the BWU are divided in two section, cancellable and not cancellable. The safety functions which is cancellable will be announced on the following indicators: Cancel Slow Down The pushbutton will, when activated, cancel slow downs which are predefined as cancellable. Cancel Shut Down The pushbutton, will when activated, cancel shut downs which are predefined as cancellable.

    The safety functions which is not cancellable will be announced on the indicators:

    Shut Down Slow Down

    Functions Push-button pressed once for activation Push-button pressed twice de-activation

    Indications The push-button LED indicator is flickering when a

    safety function is active. If the push-button is pressed and the cancel function

    is activated the LED indicator gets fixed red light. If the push-button is pressed again the cancel

    function is switched off and the LED indicator starts flickering if the Safety function is still active but extinguishes if the safety function is no longer active.

  • Instruction manual AutoChief C20

    AA-00380-A 15

    2.4.4 Lever function

    STOP

    D.SLOW

    SLOW

    HALFFULL

    NAV.FULL

    D.SLOW

    SLOW

    HALF

    FULL

    EM.AST.

    The manoeuvre lever on the bridge wing unit has the same divisions as the bridge lever. Each division has a step.

    Functions Lever to be moved to required step Electric shaft function will move lever in center

    bridge and the other bridge wing accordingly.

    Indications Illuminated scale showing each lever position.

    2.4.5 Indicators

    START AIR PRESSURE

    0

    20

    40

    rpm-100

    0

    100

    The BWU C20 includes indicators for starting air pressure, engine rpm and optionally engine pitch, The indicators does always be operative whether the wing control station is in command or not.

    Indications Start air pressure, indicates available starting air

    pressure

    Engine rpm, indicates the engine rpm in astern or ahead direction. Astern is indicated with negative (-) rpm value and red scale. Ahead is positive and green scale.

  • Instruction manual AutoChief C20

    16 AA-00380-A

    2.4.6 Panel Dimming

    Panel dim. -+

    Panel dim. -+

    Panel dim. -+

    The BWU instrumentation and lever do all include background illumination. The intensity can be adjusted by dedicated pushbuttons on the push-button panel.

    Functions By pressing + button intensity will be enhanced By pressing - button intensity will be reduced

    Indications LED indicator is lit as long as pushbutton is pressed.

  • Instruction manual AutoChief C20

    AA-00380-A 17

    2.5 AutoChief Push-Button Telegraph (PBT)

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    Nav.full

    Full

    Half

    Slow

    DeadSlow

    Stop

    DeadSlow

    Slow

    Half

    Full

    Emerg.Astern

    EmergencyStop

    Wrong way

    LampTest

    In addition to the Lever Telegraph Unit, another unit provides a simple sub telegraph system for the engine room. The Push Button Telegraph (PBT) enables an operator to transmit/receive messages between the bridge, control room and engine room. The following standard functions are available as explained above:

    Engine Telegraph Modes: Engine Telegraph Control Location Engine Telegraph Status Emergency Stop

    The following telegraph divisions are provided by push buttons with indicators: Ahead: D.Slow, Slow, Half, Full, Navigation Full, Stop Astern: D.Slow, Slow, Half, Full, Emergency Astern

    Functions Push-buttons activated for accepting and confirming

    order received from the bridge Emergency Stop pushbutton pressed once for

    activation and pressed again for reset. Lamp test pushbutton for testing all indicators and

    background illumination.

    Indications A corresponding led is lit on each pushbutton when

    activated Emergency Stop pushbutton, illumination is red.

    When active the illumination is enhanced. Wrong way alarm. The cover has a translucent section, so if its closed

    the light will show through

  • Instruction manual AutoChief C20

    18 AA-00380-A

    2.5.1 Command Transfer functions

    Bridge

    ECR

    Local

    The command transfer section is used for selecting the location for controlling the main engine Bridge The operator on the bridge is controlling the engine via the automatic Remote Control System. The Engine Telegraph System is disabled. ECR The control room personnel have control of the engine. Communication is established between the bridge and engine control room via the telegraph system Local The engine room personnel have control of the engine from the local control system. Communication is established between the bridge and engine room via the telegraph system.

    Functions Push-button pressed once for request of command Push-button pressed twice for accept of command

    Indications The push-button LED indicator is lit to confirm

    control position The push-button LED indicator is flickering when a

    control position is requested but not accepted.

  • Instruction manual AutoChief C20

    AA-00380-A 19

    2.5.2 Sub-Telegraph functions

    At sea

    Stand by

    FWE

    The sub-telegraph functions are included for informing the engine crew about the subsequent need for propulsive and electric power. At Sea The operator on the bridge is informing that all systems has to be prepared and set-up for seagoing. Stand by The operator on the bridge is informing that all systems has to be prepared for stand by. Engine to be prepared for start. It may also inform the crew that the vessel is entering channel or harbours where special attention has to be made to the machinery or steering plant. FWE ( Finished with engine) The operator on the bridge is informing that there will be no need for propulsive power. The crew will block main start valve and drain the line, Start air distributor will be locked and control air drained. For the MAN B&W engines this lamp will flicker until all actions is made to inhibit the engine to start unintentionally. This function is called FWE Loop abnormal.

    Functions Push-button pressed for request of mode

    Indications The push-button LED indicator is lit to confirm sub-

    telegraph mode

  • Instruction manual AutoChief C20

    20 AA-00380-A

    2.6 Safety switch panel

    SHUTDOWN

    SLOWDOWN

    CANCELSHUTDOWN

    CANCELSLOWDOWN

    NORMALFORCED ECR

    CONTROL NORMALINCREASE

    LIMIT

    SSP

    LAMPTEST

    RESETSLOWDOWN

    The safety switch panel is located in the engine control room

    2.6.1 Safety functions

    SHUTDOWN

    Indicates that shut down is activated.

    CANCELSHUTDOWN

    Pushbutton for cancelling shut down.

  • Instruction manual AutoChief C20

    AA-00380-A 21

    SLOWDOWN

    Indicates that slow down is activated.

    CANCELSLOWDOWN

    Pushbutton for cancelling slow down.

    NORMALINCREASE

    LIMIT

    Selector switch for increasing limiters in the remote control system.

    NORMALFORCED ECR

    CONTROL

    Selector switch for forced control take-over, from remote to Engine Control room control.

    LAMPTEST

    Pushbutton for testing all lamps in the Safety switch panel.

    RESETSLOWDOWN

    Pushbutton for reset slow down.

  • Instruction manual AutoChief C20

    22 AA-00380-A

    2.7 PBT in cabinet for ME engine

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    Nav.full

    Full

    Half

    Slow

    DeadSlow

    Stop

    DeadSlow

    Slow

    Half

    Full

    Emerg.Astern

    EmergencyStop

    Wrong way

    LampTest

    AHEAD ASTERNSTOP

    DEADSLOW

    SLOW

    HALF

    FULL

    EMERG.ASTERN

    DEADSLOW

    SLOW

    HALF

    FULL

    NAV.FULL

    For the MAN B&W ME engine the pushbutton telegraph is mounted in a cabinet together with a control dial for local control of the ME engine

    2.7.1 function and indicators AHEAD ASTERNS

    TOP

    DEADSLOW

    SLOW

    HALF

    FULL

    EMERG.ASTERN

    DEADSLOW

    SLOW

    HALF

    FULL

    NAV.FULL

    The control dial is used for local start / stop and speed control of the main engine. The dial is directly connected to the MAN B&W ECU A&B units. The control dial has a scale indicating all the telegraph positions similar to the pushbutton telegraph.

    There is also a buzzer mounted in the cabinet for announcing new telegraph commands given from the bridge to the local telegraph.

    See separate description of the pushbutton Telegraph

  • Instruction manual AutoChief C20

    AA-00380-A 23

    2.8 Distributed processing units

    2.8.1 General A number of different Distributed Processing Units are available for different tasks. The main functions of the Distributed Processing Units are to monitor analogue or digital sensors and to provide analogue and digital output to different devices. All units have the same mechanical construction and are built using the same electronic design principles. The main characteristics of the Distributed Processing Units are:

    Distributed Processing Units (DPU) LED indicators on the housing for Watch-dog, Run, General

    information, unit initialised and power polarity. Three-way isolation between: - I/O and power. - I/O and process-bus. - Power and process-bus. Single printed circuit board design. Easy service replacement without setting trimmers, dip switches,

    jumpers or sockets. No additional EMC protection required (only IP).

    Time synchronisation. Non-volatile memory. Remote alarms function. Dual CAN-bus interfaces.

  • Instruction manual AutoChief C20

    24 AA-00380-A

    Software can be downloaded into the unit. Built In Self-Test (BIST) monitoring temperature, power

    and sensor excitation overload. All parameters are stored in each unit. Each unit is remotely configurable. No serviceable parts inside. All connections are pluggable.

    Each Distributed Process Unit contains its own microprocessor. These are programmed for a number of different tasks such as detecting when a monitored signal move outside set limits. Unwanted alarms are inhibited during start-up and shut-down of the machinery. Status information is continuously monitored by the AutoChiefC20 AMSs Remote Operator Stations through the system network. When an unacceptable condition is detected, the Distributed Process Unit and AutoChiefC20 AMS generates an alarm signal, identifies the responsible sensor, and provides information about the condition. The following gives a short description of each Distributed Processing Unit type:

  • Instruction manual AutoChief C20

    AA-00380-A 25

    2.8.2 Dual Process Segment Controller (dPSC)

    The dual Process Segment Controller (dPSC) is a dual two channel CAN gateway. Its main task is to process messages from the local CAN segment and send them on the global process bus, where they are available for other dPSCs and the Remote Operator Stations. In most cases the two channels are working in parallel on redundant CAN lines. Commands and downloading of parameters and software from any Remote Operator Station to the Distributed Processing Units connected to the local process bus is handled as well. The main features are:

    Redundant routing of messages between local and global CAN segments.

    Application mastership with active running backup. PLC algorithm for controlling I/O-signals connected to the

    local DPUs.

    Self checking Remote configurable No serviceable parts All connections pluggable All parameters stored in module Dual redundant 24VDC input (power)

  • Instruction manual AutoChief C20

    26 AA-00380-A

    2.8.3 RPMD Unit (RPMD) The RPMD module is a module with pickup inputs and digital outputs, two relay output and two solenoid driver output. The value from the pickups can be used to activate the outputs and will be reported on CAN. The main features are: 4 pickup inputs, 2 or 3 wire (NPN or PNP pickup required). 2 Relay output, one changeover contact 2 channels for Solenoid driver

    Scaled in technical units. Limit check. Alarm and monitoring for all channels. Trend. Time stamp of alarms and events (0.001 seconds). Self checking. Sensor excitation power overload. CAN net status, error handling.

    RPMD C20

  • Instruction manual AutoChief C20

    AA-00380-A 27

    2.8.4 Remote Analogue Input (RAi-16) This unit has 16 analogue input channels. Each channel is selectable as voltage, current and resistance input in different ranges and has free technical units scaling. It also incorporates a 5-500Hz counter channel. The main features are:

    16 analogue or digital input channels. Scaled in technical units. 1 Counter 5 - 500 Hz. Limit check. Alarm and monitoring for all channels. Trend. Time stamp of alarms and events (0.001 seconds). Self checking. Sensor excitation power overload. CAN net status, error handling.

  • Instruction manual AutoChief C20

    28 AA-00380-A

    2.8.5 Remote Analogue Input (RAi-10tc) This unit has 10 analogue input channels. It is used for temperature measurements with Thermo Coupler (TC) elements of different type. It is particularly suited to monitor engine exhaust temperatures. A large variety of temperature elements can be connected, with ranges 50, 200, 0 to + 600C. A Cold Junction Compensation function is included. If external compensation is needed, the use of external Thermo Coupler amplifiers and RAi-16 is recommended. The main features are:

    10 thermo-coupler input channels. Scaled in technical units. Limit check. Alarm and monitoring for all channels. Trend. Time stamp of alarms and events. Self checking. Sensor excitation power overload. CAN net status, error handling.

  • Instruction manual AutoChief C20

    AA-00380-A 29

    2.8.6 Remote Digital Input (RDi-32 and RDi-32a)

    These units have 32 digital input channels/dry contacts and includes LED status indicators. The main features are:

    32 digital input channels with LED status indicators. Input dry contacts. Alarm and monitoring for all channels. Trend. Time stamp of alarms and events. Self checking. Sensor excitation power overload. CAN net status, error handling.

    2.8.7 Remote Analogue Output (RAo-8) This unit has 8 analogue output channels. Each channel is selectable for voltage or current output in different ranges and almost free technical units scaling. This module is suited to drive analogue indicators. By placing the module close to instruments long cables can be avoided. The main features are:

    8 analogue output channels. 10VDC / 20 mA. CAN net status, error handling.

  • Instruction manual AutoChief C20

    30 AA-00380-A

    2.8.8 Remote Digital Output (RDo-16) This unit has 16 digital output channels and includes LED status indicators. The maximum output current for each channel is 3 Amperes (resistive load). Maximum voltage is 230 VAC. The main features are: 16 digital output channels with LED status indicator. The main features are:

    Change over, brake before make relay-contacts. Pulse on output. Pulse off output. CAN net status, error handling.

    2.8.9 Process Segment Starcoupler (PSS)

    CAN lines are vulnerable against short circuit and un-terminated lines. A short-circuit or a broken line will disable the entire CAN segment. The PSS will protect two sections of a CAN segment from each other. A typical application is to protect CAN segments running across fire- or flood-zones.

    Protection of sections in a single CAN segment Extension of bus topology No configuration No serviceable parts All connections pluggable

  • Instruction manual AutoChief C20

    AA-00380-A 31

    2.9 Remote control system functions

    2.9.1 Start fail/block As long as any of the below mentioned conditions is active the engine is inhibited for starting.

    2.9.1.1 Start failed Starting failure is announced from the MAN B&W ECS when one of the following conditions occurs, and is indicated on ECR and Bridge ACP.

    3 failed starts Slow turning failure

    2.9.1.2 Start air pressure low

    To secure a safe starting of the main engine a minimum starting air pressure is required. The value for minimum starting air pressure allowed is preset in parameters in the remote control system. If the pressure is below this preset level Start Block is activated.

    2.9.1.3 Engine tripped

    Engine has tripped because of a shut down detected and created by the safety system.

    Details to be found in the alarm list on the Safety system mimic pages.

    2.9.1.4 Start blocked

    If one or more of the following conditions are present the ECS will block the start:

    Shut down Main starting valve blocked Starting air distribution system blocked Control air vented Turning gear engaged Starting air pressure low and bridge control active Auxiliary blowers not operational and bridge control active

  • Instruction manual AutoChief C20

    32 AA-00380-A

    When the start is blocked the ECS will release an alarm and route Start Blocked signal to the RCS via the serial connection. The ECS will automatically reset the start blocking when the condition has returned to normal and stop command is released.

    2.9.1.5 Engine blocked

    This is a signal from the Electronic Control System to the remote control system via serial line informing that the engine is blocked for operation. Its active if one or all of the following conditions is active:

    Main starting valve blocked Starting air distribution system blocked Control air vented

    2.9.2 Engine state ECS

    2.9.2.1 Start air distributor blocked

    For safety reasons, when the main engine is not in use, the start air distributor is blocked. To be able to start the engine the start air distributor has to be unblocked.

    2.9.2.2 Main Start air valve blocked

    For safety reasons, when the main engine is not in use, the main start air valve is mechanically blocked. To be able to start the engine the main start air valve has to be unblocked.

    2.9.2.3 Turning gear engaged

    The turning gear is mechanically engaged to the flywheel. The main engine is therefore inhibited from starting.

    2.9.2.4 Control air vented

    The control air valve is closed and the line is pressure released with a ventilation valve.

  • Instruction manual AutoChief C20

    AA-00380-A 33

    2.9.2.5 Engine not ready/ready

    Engine Not Ready is used for an indication at the bridge, ECR and LOP. The purpose of the Engine Not Ready indication is to inform the navigator/engine staff that the engine is not fully capable of functioning. For example it may not be possible to start the engine again if it has been stopped.

    It is allowed to perform a start attempt if the Engine Not Ready indication is on. However, the normal procedure is to wait until Engine Not Ready deactivates before a start attempt is carried out e.g. after black-out.

    The ECS will route Engine Not Ready to the remote control system via serial connection. The Engine Not Ready signal is set active if the condition for engine ready is not fulfilled Engine Not Ready is thus the inverse of the following signals:

    Main starting valve in service position Starting air distribution system in service position Turning gear disengaged Control air pressure OK Hydraulic supply system OK Auxiliary blowers operational ECS OK

  • Instruction manual AutoChief C20

    34 AA-00380-A

    2.9.3 Starting the main engine The engine is started automatically in ahead (or astern) direction from bridge (if the engine is prepared for start), simply by setting the bridge handle from stop to any position in ahead (or astern) direction.

    2.9.3.1 Prepare Start.

    This function is activated from the ACP mimic pages, its activated for starting the auxiliary blowers prior to the normal start of the engine. As long as this sequence is not performed the engine will be in the state Delayed Start. When the sequence is ready the engine state will be Ready for Start,

    2.9.3.2 Starting Starting of the main engine is performed when the bridge lever is moved from stop to any position in ahead (or astern direction). The remote control system will send a signal called Not Stop through a switch in the LTU and a current signal (420 mA) informing the ECS about rpm request and thrust direction.

    2.9.3.3 Repeated start If the engine fails to start (run on fuel) after the starting air is switched off, the system will automatically try to restart the engine. Indication for "repeated starts" will show on bridge and ECR. If the second start also fails, the system will try once more. After 3 starting attempts, start failed alarm will be activated.

    2.9.3.4 Running The signal Running is transferred to the RCS from the ECS when the engine is running on fuel.

  • Instruction manual AutoChief C20

    AA-00380-A 35

    2.9.4 RPM limiters For protecting the engine against thermal stress and destruction some fixed RPM Limiters are included in the ECS.

    2.9.4.1 Load Limitation

    This function is including the operational limiters:

    Chief rpm limit Torque Limiter Scavenging air Limiter

    The limiter functions is adjustable only in the MAN B&W ECS.

    2.9.4.2 Slow Down A slow down is caused by a input signal detected by the slow down module. If such a signal is detected, the safety system will send a slow down request to the ECS. The speed set-point will after a pre-warning time be reduced to the predefined slow down level.

    Time

    RPM

    SLD RPMLevel

    SLD Active During pre-warning time an alarm "slow down cancellable" or "slow down none cancellable" will be displayed on the ACP.

    2.9.5 Operation modes

    2.9.5.1 Emission mode

    This mode is selectable from the ACP mimic. Emission mode is a special feature controlled by the MAN B&W Electronic Control System. It secures operation of the main engine with the lowest emissions for the actual engine type.

  • Instruction manual AutoChief C20

    36 AA-00380-A

    2.9.5.2 Economy mode

    This mode is selectable from the ACP mimic. Economy mode is a special feature controlled by the MAN B&W Electronic Control System. It secures the operation of the main engine with the lowest consumption and thereby in the most economic way.

    2.9.6 Reversing the main engine The engine is reversed automatically to ahead (or astern) direction from bridge by setting the bridge handle from stop to any position in ahead (or astern) direction. Reversing sequence will be carried out prior to the starting sequence. If the engine is running above the brake air level, brake air will be supplied when engine has reached down to brake air level, in order to perform the reversing sequence as fast as possible.

    2.9.7 Stopping the main engine The engine is stopped automatically by setting the bridge handle to STOP position. The stop solenoid valve is activated, and stop signal is given to governor to set the fuel rack in zero position.

  • Instruction manual AutoChief C20

    AA-00380-A 37

    2.10 Safety system functions

    2.10.1 Safety function Shut down

    2.10.1.1 Shut Down Function (1 6) Then engine will automatically shut down (stop), if any of the shut down sensors is activated. The emergency stop solenoid valve will be activated, and the fuel rack to zero order is given to the governor. The engine will then stop. The following inputs for shut down sensors are provided: Shut down 1: (Fixed as over speed) Shut down 2-6: (To be project specified for the actual

    project) Custom Shut down 1-5 (To be project specified for the actual

    project) The input sensors may be of digital (on/off) or analogue type. The shut downs may be configured as cancellable or non cancellable type. Non cancellable types will stop the engine immediately. Shut down is reset (after the sensor is de-activated) by setting the manoeuvring lever at the control stand in control to stop position. The engine may then be restarted.

    2.10.1.2 Cancellable Shut Down It will be possible, during the time delay, to cancel the shut down by pressing the "Cancel SHD" pushbutton on the ACP unit. There will be time delay on the cancellable shut downs. The delay time may be adjusted individually for each sensor. The cancellable shut-downs may be cancelled individually from the ACP in control room, regardless of control position, it will additionally be possible to cancel all shut-downs from bridge while in bridge control, control room in control room control and from engine side while in emergency control. The indications mentioned will be shown on the LCD display of the ACP unit.

  • Instruction manual AutoChief C20

    38 AA-00380-A

    2.10.1.3 Emergency Stop function Safety System has possibility for total 5 emergency stop push buttons Normally 3 emergency stop pushbuttons will be used:

    Bridge Pushbutton with light with integrated in bridge LTU.

    Control Room Pushbutton with light with cover integrated in the ECR LTU

    Local Control: Pushbutton with light with cover integrated in emergency control PBT.

    Emergency stop solenoid valve is directly activated through the ESU when one of the pushbuttons is activated. Stop signal is sent to the RCS and fuel rack to zero order is given to the governor. The engine will stop, and an alarm "emergency stop", emergency stop valve activated", and information of which of the emergency stop pushbutton is activated will be shown on the ACP. Emergency stop may be activated from all control stands at all time, regardless of the control position. Emergency stop is simply deactivated when the pushbutton are pressed once more.

    2.10.1.4 Over-speed Shut Down Over speed is detected by the RPM detection system, from tacho pick-ups which are mounted towards engine fly-wheel, when the engine revolution exceeds the over speed level (107% of MCR, adjustable). A hardwired signal from the RPM detection system is connected to a shut down input on the ESU for direct activation of emergency stop solenoid valve. And the RPM detection system will by dual redundant CAN order shut down of engine to RCS, Safety System and Governor System. This will cause the emergency stop solenoid valve to be activated and the fuel rack position moved to zero. The engine will stop and the alarm "over speed" will be shown on the ACP. Over speed is reset by setting the manoeuvring lever at the control stand to stop position. The engine may then be restarted.

  • Instruction manual AutoChief C20

    AA-00380-A 39

    2.10.2 Safety function Slow Down

    2.10.2.1 Slow Down Function (1 20) The engine will automatically reduce the speed corresponding to slow (adjustable) if any of the slow down sensors is activated. Slow down signal will be sent to the remote control system and/or the governor, which takes action. Slow down is indicated on the ACP. The inputs for slow down sensors are as follows: Slow down 1-20: (To be project specified for the actual

    project) The input sensors may be of digital (on/off) or analogue type. The slow downs may be configured as cancellable or non cancellable type. Non cancellable types will reduce the engine speed immediately; while there will be time delay on the cancellable ones. The delay time may be adjusted individually for each sensor. The cancellable slow-downs may be cancelled individually from the ACP in control room, regardless of control position, it will additionally be possible to cancel all slow-downs from bridge while in bridge control, control room in control room control and from engine side while in emergency control. Slow down is automatically reset after the sensor is de-activated, alternatively it is reset when the sensor is de-activated, and the bridge handle is set below the slow down level. A none cancellable slowdown will activate speed reduction immediately after the time delay has run out. Slow down action is performed as follows:

    Bridge Control Automatically by the remote control system.

    Control Room Contr. Automatically by the governor or manually by the operator

    Local Control: Manually by the local speed device.

  • Instruction manual AutoChief C20

    40 AA-00380-A

    2.10.2.2 Cancellable Slow Down It will be possible during the time delay to cancel the slowdown by pressing the "Cancel SLD" pushbutton on the ACP unit. If not cancelled, the slow down will be activated and be indicated as "slow down activated" and the speed set-point will be reduced to the slow down level, normally corresponding to dead slow (adjustable). It will be possible to adjust main engine speed in the area between minimum run and slow down level. Slow down is reset automatically, when the slow down signal goes off. The indications mentioned will be shown on the LCD display of the ACP unit.

  • Instruction manual AutoChief C20

    AA-00380-A 41

    2.11 RPM measurement functions

    2.11.1 Dual engine speed detector system for MAN B&W ME Engines The AutoChiefC20 is furnished with two independent RPM measurement systems. These systems will at all time ensure correct reading of the RPM pickups and give alarm in case of irregularities.

    There is a hardwired connection for activating overspeed shut down from the RPME to the ESU (Safety system). The RPM detector system is used to detect over speed, critical RPM, wrong rotation as well as driving a variety of RPM indicators located on bridge, in control room and engine side.

    2.11.2 RPM detector failure RPM monitoring is critical for starting and running of the engine, So if the RPM measuring system is experiencing a redundant detector failure the engine is inhibited for starting. A principle diagram of the RPM detector system is shown below:

    RPMEPick-ups RPMERPMD

    Notchfilter

    Low passfilter

    Displayfilter

    ESU

  • Instruction manual AutoChief C20

    42 AA-00380-A

    3 OPERATING INFORMATION

    3.1 Introduction This chapter describes normal operation from the different control locations for a normal delivery. This covers operation from the following locations:

    Bridge Bridge Wings Engine Control Room Local Control Stand The operational description is built on the case that the engine shall be started ahead, stopped and reversed for starting astern from each control location. Normal events during these operations are described. More advanced operations is not covered in this chapter.

  • Instruction manual AutoChief C20

    AA-00380-A 43

    3.2 AutoChief Control Panel (ACP)

    3.2.1 General operation from bridge.

    3.2.1.1 Preparing engine for start in ECR

    Before starting the engine it has to be made ready for start.

    1. Use the Rotary knob and scroll to the soft key Engine State

    2. Press the Rotary knob for activating Engine State.

    30 bar

    0 rpm

    0 %0 rpm 0 rpm

    Stopped

    120-120

    -60 600

    ME RPM

    400

    10 3020

    50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    HOMEB&W ModesSafety System

    Fine TuningMisc MenuControl Pos.LimitersAlarms

    Stand by ECR Eng Ready System ReadySTART AIR PRESS

    FUEL INDEX

    LEVERSETP

    Engine State

    3. Observe the start block conditions and act accordingly.

    ECR Eng Ready System ReadyStand by

    Start BlockedReady for StartDelayed StartPreparing StartStarting

    STATEStart failedSTART FAIL/BLOCK

    Start air distributor blockedMain start air valve blockedTurning gear engaged

    ENGINE STATE ECS

    Control air vented

    Start air pressure low

    Start blockedEngine tripped

    Engine blockedRepeated StartRunningStoppingEngine Tripped

    HOMEEngine LineEngine State

    Engine not ready

  • Instruction manual AutoChief C20

    44 AA-00380-A

    4. When all start block conditions is cancelled the engine is ready for start.

    ECR Eng Ready System ReadyStand by

    Start BlockedReady for StartDelayed StartPreparing StartStarting

    STATEStart failedSTART FAIL/BLOCK

    Start air distributor blockedMain start air valve blockedTurning gear engaged

    ENGINE STATE ECS

    Control air vented

    Start air pressure low

    Start blockedEngine tripped

    Engine blockedRepeated StartRunningStoppingEngine Tripped

    HOMEEngine LineEngine State

    Engine not ready

    3.2.1.2 Transfer control from ECR to Bridge

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    STOP

    EmergencyStop

    Bridge

    ECR

    Local

    Bridge

    ECR

    Local

    Incommand

    Soundoff

    Alarmackn.

    1. Press the pushbutton Bridge on the LTU in ECR.

    2. The led in the pushbutton marked bridge flickers, buzzers sounds in ECR and Bridge.

    3. The upper section of the ACP mimic Home, changes status.

    Control transfer Eng Ready System ReadyStand by 4. Press the pushbutton Bridge on the LTU on the bridge.

    5. The led in the pushbutton marked ECR extinguishes.

    6. The led in the pushbutton Bridge turns to steady light. Buzzers on the bridge and in ECR turns off

    7. The upper section of the Home mimic changes status.

    Bridge Eng Ready System ReadyStand by 8. Control station is now bridge, and the led In Command

    is lit on the ACP

  • Instruction manual AutoChief C20

    AA-00380-A 45

    3.2.1.3 Start Auxilliary blowers

    1. Select the B&W modes page.

    HOMEB&W ModesSafety System

    Fine TuningMisc MenuControl Pos.LimitersAlarms

    Engine State The B&W Modes page will appear on the screen.

    At Sea Bridge Eng Ready System Ready

    Engine Running Mode

    Emmission Mode

    Prepare Start

    Economy Mode

    Spare

    Spare

    Preparing Start

    Start Blocked

    2. Navigate to the field Preparing Start. At Sea Bridge Eng Ready System Ready

    Engine Running Mode

    Emmission Mode

    Prepare Start

    Economy Mode

    Spare

    Spare

    Preparing Start

    Start Blocked

    3. This function will start the auxiliary blowers and the field below the preparing Start will change the text to Ready for start when the sequence is ready

  • Instruction manual AutoChief C20

    46 AA-00380-A

    3.2.1.4 Start engine ahead

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    D.SLOW

    EmergencyStop

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    FULL

    EmergencyStop

    1. Move the bridge lever from Stop to any position ahead.

    2. Observe the ACP mimic.

    26 bar

    24 rpm

    12 %24 rpm 24 rpm

    Running

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    HOMEEngine StateSafety System

    Misc MenuControl Pos.LimitersAlarms

    Bridge Eng Ready System ReadyStand by

    3. The engines rpm, fuel index, available starting air. press.

    can be monitored.

    4. Increase to full speed by moving the lever to requested position.

    26 bar

    58 rpm

    48 %58 rpm 96 rpm

    Running

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    HOMEEngine StateSafety System

    Misc MenuControl Pos.LimitersAlarms

    Bridge Eng Ready System ReadyStand by

    Man RPM Lim.

    5. Observe that the lever command is set to Full and 96 RPM. The graph SETP indicates 58 rpm, this means that a limiter is active.

  • Instruction manual AutoChief C20

    AA-00380-A 47

    6. To inspect which limiter that is active, use the rotary knob and navigate to the Limiters page and press the knob for activation.

    Control Pos.LimitersAlarms

    7. This picture indicates which limiter that is active.

    48 rpm 48 rpm

    LEVERSETP120967248240

    -120-96-72-48-24

    HOMELoad ProgramShow LimitersLim. CurvesSet Limiter

    Bridge Eng Ready System ReadyStand by

    Load LimitationRPM Limiters

    8. To be able to increase the rpm, this limiter has to be adjusted to a higher value.

  • Instruction manual AutoChief C20

    48 AA-00380-A

    3.2.1.5 Stop engine

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    STOP

    EmergencyStop

    1 Move the bridge lever to Stop position.

    2 The RPM will be reduced according to preset limiters in the system such as load program, acceleration limiter and critical RPM limiter.

    36 bar

    0 rpm

    0 %0 rpm 0 rpm

    Stopped

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 SETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    Bridge Eng Ready System ReadyAt Sea

    LEVER

    3.2.1.6 Start engine astern

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    D.SLOW

    EmergencyStop

    1 Move the bridge lever to any position in astern direction.

    2 The start sequence will be activated. As the lever command is lower than the required start set point the engines rpm will, during the start sequence, increase above the requested rpm. This is just during the start sequence.

    28 bar

    30 rpm

    40 %-30 rpm -24 rpm

    Starting

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 SETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    Bridge Eng Ready System ReadyAt Sea

    LEVER

    Start setpoint limit

    3 As soon as the start sequence is ready the engines rpm will

    stabilize according to the request initiated by the manoeuvre lever.

  • Instruction manual AutoChief C20

    AA-00380-A 49

    3.2.2 Normal operations from Bridge

    3.2.2.1 Cancel SHD

    CancelSHD

    CancelSLD

    Cancellimits

    CancelSHD

    CancelSLD

    Cancellimits

    During normal operation a shutdown message will appear like the figure below. Its stated whether the SHD is cancellable or not. If its cancellable and if it is required to keep ships speed follow the instructions below.

    26 bar

    72 rpm

    45 %72 rpm 72rpm

    Running

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    Bridge Eng Ready System ReadyAt Sea

    SHUT DOWN

    SHUT DOWN ACTIVE

    Engine will be stopped

    SHUTDOWN ALARM, CANCELLABLE

    1 Between detection and activation of a shut down there is a

    time delay. Shut down should be cancelled before its activated.

    2 Press the pushbutton Cancel SHD on the ACP.

    3 Engine will keep on running

    4 Press Cancel SHD pushbutton again and the shut down goes active.

    26 bar

    38 rpm

    0 %0 rpm 72rpm

    STOPPING

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    SHUT DOWN ACTIVEJACKET COOLING W. TEMP HIGH

    Bridge Eng Ready System ReadyAt Sea

    SHUT DOWN

    Note!

    Its possible to cancel the shut down also after its activated. As long as the engine does rotate with a speed above whats obtainable on starting air, the stop valve will be released and fuel applied to the engine.

  • Instruction manual AutoChief C20

    50 AA-00380-A

    3.2.2.2 Cancel SLD

    CancelSHD

    CancelSLD

    Cancellimits

    CancelSHD

    CancelSLD

    Cancellimits

    During normal operation a slow down message will appear like the figure below. Its stated whether the SLD is cancellable or not. If its cancellable and if it is required to keep ships speed follow the instructions below.

    26 bar

    72 rpm

    45 %72 rpm 72rpm

    Running

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    Bridge Eng Ready System ReadyAt Sea

    SLOW DOWN

    SLOW DOWN ACTIVE

    Engine speed will be reduced

    SLOWDOWN ALARM, CANCELLABLE

    1 Between detection and activation of a slow down there is

    a time delay. Slow down should be cancelled before its activated.

    2 Press the pushbutton Cancel SLD on the ACP.

    3 Engine will keep the requested rpm.

    4 Press Cancel SLD pushbutton again and the slow down goes active.

    26 bar

    38 rpm

    25 %38 rpm 72rpm

    Running

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    SLOW DOWN ACTIVETHRUST PAD HIGH TEMP, SLDN

    Bridge Eng Ready System ReadyAt Sea

    SLOW DOWN

    Note!

    Its possible to cancel the slow down function also when no function is active, this is normal i.e. during maintenance work

  • Instruction manual AutoChief C20

    AA-00380-A 51

    3.2.2.3 Cancel Limits

    CancelSHD

    CancelSLD

    Cancellimits

    CancelSHD

    CancelSLD

    Cancellimits

    1 Press the pushbutton Cancel Limits on the ACP.

    2 The led indicator is lit and the text Limits cancelled from ACP will appear in the ACP display.

    26 bar

    96 rpm

    80 %96 rpm 120 rpm

    Load program active

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    LIMITS CANCELLED FROM ACP

    Bridge Eng Ready System ReadyAt Sea

    Running

    3 Press the pushbutton Cancel Limits once more and the

    function is disabled.

    3.2.2.4 Sound off

    Incommand

    Soundoff

    Alarmackn.

    Incommand

    Soundoff

    Alarmackn.

    1 Press the pushbutton Sound Off on the ACP for silencing of buzzer.

    2 The led indicator is lit until pushbutton is pressed.

  • Instruction manual AutoChief C20

    52 AA-00380-A

    3.2.2.5 Alarm ack.

    Incommand

    Soundoff

    Alarmackn.

    Incommand

    Soundoff

    Alarmackn.

    26 bar

    72 rpm

    45 %72 rpm 72rpm

    Running

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    JACKET COOLING WATER TEMP. HIGH

    HOMEEngine StateSafety System

    Misc MenuControl Pos.LimitersAlarms

    Bridge Eng Ready System ReadyAt Sea

    SLOW DOWN

    SLOW DOWN ACTIVE

    Engine speed will be reduced

    SLOWDOWN ALARM, CANCELLABLE

    1 Press the pushbutton Alarm Ack. on the ACP for

    Accepting alarm.

    2 The Led indicator beside the soft keys Alarms and Safety System is lit.

    HOMEB&W ModesSafety System

    Fine TuningMisc MenuControl Pos.LimitersAlarms

    Engine State 3 Use the rotary knob to navigate to the page Alarm, press

    the knob for activating the picture

    4 Observe the Alarm page and verify which alarm conditions that are present.

    Al.Summary

    HOMEGovernor FailI/O FailSys. Non-Crit.Sys. Critical

    At Sea Bridge Eng Ready System ReadyDescription Value Alarm

    JACKET COOLING WATER TEMP. HIGH HIGH HIGH

    JACKET COOLING WATER PRESS. LOW LOW LOW

    Tags in alarm:

  • Instruction manual AutoChief C20

    AA-00380-A 53

    3.2.3 General Operation from the bridge Wing.

    3.2.3.1 Transfer from bridge to bridge wing

    Before manoeuvring from the bridge wing is possible the control has to be transferred from bridge to bridge wing.

    ASTERN AHEAD

    EMERGENCY STOP

    BWU C20BRIDGE WING UNIT

    STOP

    D.SLOW

    SLOW

    HALFFULL

    NAV.FULL

    D.SLOW

    SLOW

    HALF

    FULL

    EM.AST.

    rpm-100

    0

    100

    START AIR PRESSURE

    0

    20

    40

    Transfer functions

    Cancel SHD

    Cancel SLD

    In Command

    Panel dim. -+

    Shut Down

    Slow Down

    Not Cancellable

    CancellableSafety functions

    In Command

    STOP

    D.SLOW

    SLOW

    HALFFULL

    NAV.FULL

    D.SLOW

    SLOW

    HALF

    FULL

    EM.AST.

    In Command

    1 Press the pushbutton In Command on the BWU C20 panel for control take over.

    2 The led indicator will flash until transfer is ready.

    3 The lever will start to move to match position with the bridge lever. This is an automatic function.

    4 The led indicator in the In Command pushbutton will turn to steady light when the control is transferred.

  • Instruction manual AutoChief C20

    54 AA-00380-A

    3.2.3.2 Manoeuvring from the bridge wing

    The control position is now the bridge wing. The operation is the same whether the port or starboard wing is selected.

    ASTERN AHEAD

    EMERGENCY STOP

    BWU C20BRIDGE WING UNIT

    STOP

    D.SLOW

    SLOW

    HALFFULL

    NAV.FULL

    D.SLOW

    SLOW

    HALF

    FULL

    EM.AST.

    rpm-100

    0

    100

    START AIR PRESSURE

    0

    20

    40

    Transfer functions

    Cancel SHD

    Cancel SLD

    In Command

    Panel dim. -+

    Shut Down

    Slow Down

    Not Cancellable

    CancellableSafety functions

    STOP

    D.SLOW

    SLOW

    HALFFULL

    NAV.FULL

    D.SLOW

    SLOW

    HALF

    FULL

    EM.AST.

    STOP

    D.SLOW

    SLOW

    HALFFULL

    NAV.FULL

    D.SLOW

    SLOW

    HALF

    FULL

    EM.AST.

    rpm-100

    0

    100

    AHEADASTERN

    1 Use the lever for selecting required rpm and direction of thrust. The bridge lever will follow the bridge wing lever.

    2 Stop Engine by moving the lever to Stop position.

    3 The rpm is monitored on the rpm indicator.

  • Instruction manual AutoChief C20

    AA-00380-A 55

    STOP

    D.SLOW

    SLOW

    HALFFULL

    NAV.FULL

    D.SLOW

    SLOW

    HALF

    FULL

    EM.AST.

    rpm-100

    0

    100

    AHEADASTERN

    Transfer functions

    Cancel SHD

    Cancel SLD

    In Command

    Panel dim. -+

    Shut Down

    Slow Down

    Not Cancellable

    CancellableSafety functions

    EMERGENCY STOP

    EMERGENCY STOP

    4 Start engine astern by moving the lever to any position in astern direction.

    5 Observe that the engine start and run astern.

    Safety functions are divided in cancellable and not cancellable. If a cancellable safety function appears follow the description below. A none cancellable safety function will appear like this:

    Shut Down Slow Down

    6 To cancel Shut Down use the dedicated pushbutton.

    Cancel SHD

    7 To cancel Slow Down, use the dedicated pushbutton.

    Cancel SLD

    8 To Activate Emergency Stop, lift the protection cover

    9 Press the pushbutton, and emergency stop is activated.

    10 To reset emergency stop the pushbutton has to be pressed once more. Manoeuvre lever in command to be set to stop, then engine can be started again

  • Instruction manual AutoChief C20

    56 AA-00380-A

    3.2.3.3 Transfer from Bridge Wing to Bridge

    Bridge Wing Control is a sub mode of bridge control. To take the control back from bridge wing the following procedure has to be used

    CancelSHD

    CancelSLD

    Cancellimits

    Incommand

    Soundoff

    Alarmackn.

    36 bar

    0 rpm

    0 %0 rpm 0 rpm

    Stopped

    120-120

    -60 60

    0ME RPM START AIR PRESS LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    HOMEEngine StateSafety System

    Misc MenuControl Pos.LimitersAlarms

    At Sea Bridge Eng Ready System Ready

    400

    10 3020

    B&W Modes

    Incommand

    Soundoff

    Alarmackn.

    Incommand

    Soundoff

    Alarmackn.

    The upper section of the ACP page Home indicates that the Bridge Wing control station is in control.

    Port Wing Eng Ready System ReadyAt Sea 1. Press the pushbutton In Command on the ACP on the

    bridge

    2. The led in the pushbutton marked In Command, indicates that the bridge main operation station is in control

    3. The upper section of the ACP mimic Home, changes status.

    Bridge Eng Ready System ReadyAt Sea

  • Instruction manual AutoChief C20

    AA-00380-A 57

    3.2.4 General operation from ECR. When the engine is operated from control room, orders for rpm and direction of thrust is given from the bridge. The telegraph system is active by transmitting orders from bridge to control room. The order is confirmed in control room by moving the lever to the position that is requested from bridge.

    3.2.4.1 Transfer control from bridge to ECR

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    STOP

    EmergencyStop

    Bridge

    ECR

    Local

    Bridge

    ECR

    Local

    Incommand

    Soundoff

    Alarmackn.

    1. Press the pushbutton ECR on the LTU in the bridge.

    2. The led in the pushbutton marked ECR flickers, buzzers sounds in ECR and Bridge.

    3. The upper section of the ACP mimic Home, changes status.

    Control transfer Eng Ready System ReadyStand by 4. Press the pushbutton ECR on the LTU in the ECR.

    5. The led in the pushbutton marked bridge extinguishes.

    6. The led in the pushbutton ECR turns to steady light. Buzzers on the bridge and in ECR turns off

    7. The upper section of the Home mimic changes status.

    ECR Eng Ready System ReadyStand by 8. Control station is now ECR, and the led In Command is

    lit on the ACP in the control room.

  • Instruction manual AutoChief C20

    58 AA-00380-A

    3.2.4.2 Start engine ahead

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    D.SLOW

    EmergencyStop

    Bridge

    ECR

    Local

    At sea

    Stand by

    FWE

    FULL

    EmergencyStop

    1. Move the ECR lever from Stop to any position ahead.

    2. Observe the ACP mimic.

    26 bar

    24 rpm

    12 %24 rpm 24 rpm

    Running

    120-120

    -60 600

    ME RPMSTART AIR PRESS

    400

    10 3020 LEVERSETP

    FUEL INDEX50

    1000

    25 75

    120967248240

    -120-96-72-48-24

    HOMEEngine StateSafety System

    Misc MenuControl Pos.LimitersAlarms

    Bridge Eng Ready System ReadyStand by

    3. The engines rpm, fuel index, available starting air. press.

    can be monitored.

    4. Increase to full speed by moving the lever to requested position.

    26 bar

    58 rpm

    48 %58 rpm 96 rpm