a hard x-ray coherent scattering beamline for nsls-ii alec sandy, x-ray science division argonne...
Embed Size (px)
TRANSCRIPT

A Hard X-Ray Coherent Scattering Beamline for NSLS-II
Alec Sandy,
X-Ray Science Division
Argonne National Laboratory
& SAXS?

2
Acknowledgements
Design to be discussed today represents work primarily performed by:
– Scott Coburn, Brookhaven National Laboratory
– Simon Mochrie, Yale University
– Ian Robinson, University College London
Many helpful conversations with:
– Larry Lurio, Northern Illinois University
– Brian Stephenson, Argonne National Laboratory
– Mark Sutton, McGill University

3
Outline
Beamline Mission
Supported Techniques
Lay of the Land
NSLS-II Strengths
Beamline Requirements
Design Philosophy
Conceptual Design
Possible Discussion Items

4
Beamline Mission
Application of hard (7–12 keV) coherent x-rays to the study of nanoscale dynamics and structure of complex materials
– Equilibrium dynamics and fluctuations about the evolution to equilibrium in colloids, polymers, membranes, concentrated proteins, glasses, …
– 3-D imaging of microscopic non-crystalline objects such as catalytically active materials, cavities within steel, defect structures in magnetic multilayers, cellular imaging
Mark A. Pfeifer, Garth J. Williams, Ivan A. Vartanyants, Ross Harder, and Ian K. Robinson, “Three-dimensional mapping of a deformation field inside a nanocrystal,” Nature 442, 63 (2006)
O. G. Shpyrko, E. D. Isaacs, J. M. Logan, Yejun Feng, G. Aeppli, R. Jaramillo, H. C. Kim, T. F. Rosenbaum, P. Zschack, M. Sprung, S. Narayanan, and A. R. Sandy; "Direct measurement of antiferromagnetic domain fluctuations," Nature 447, 68

5
Supported Techniques
Techniques to be employed
– X-ray photon correlation spectroscopy (XPCS) or x-ray intensity fluctuation spectroscopy (XIFS)• X-ray analog of dynamic light scattering
– Coherent x-ray diffraction (CXD)• Coherent x-rays and intensity over-sampling to determine the
nanoscale structure of micron sized crystals via phase retrieval and inversion
– Coherent x-ray diffraction imaging (CXDI)• Coherent x-rays and intensity over-sampling to determine the
nanoscale structure of non-periodic objects via phase retrieval and inversion– Lensless imaging, ptychography, CXDI
– SAXS
– Imaging• Phase contrast imaging• Diffraction enhanced imaging

6
Lay of the Land ESRF (6 GeV)
– General purpose beamline evolving to XPCS and CXD(I) specialization• Small Q XPCS, considerably less large Q XPCS and CXDI: ID-10
APS (7 GeV)– Dedicated XPCS beamline but not (yet) CXD/CXDI
• Small Q XPCS and considerably less large Q XPCS: 8-ID• CXD (large Q) but limited GU program: 34-ID• CXDI (small Q): ?
SPRing 8– Little activity
SLS (2.4 GeV)– SAXS, XPCS, CXDI: cSAXS
• Sophisticated and advanced detector program but lower energy ring and shorter beamlines
Petra III (6.0 GeV)– Tandem endstations: large Q XPCS, CXD and XPCS and CXDI
• Planning phase: 2009–2010 completion—long straights and beamlines Diamond (3.0 GeV)
– USAXS/XPCS branch, CXDI/CXD multiplexed with full-field imaging: I13• 250 m beamline length• Planning phase: 2010–2011 completion

7
NSLS-II Strengths
Unprecedented brightness
– Both XPCS and CXD remain signal starved techniques• CXD “improves” linearly with brightness– Measurement times from hours to minutes
• XPCS “improves” quadratically with brightness– 30× more incident intensity → 1,000× faster dynamics
Existing strong community in soft condensed matter science and a relatively local XPCS community
Soft and hard x-ray coherent x-ray scattering Existing, innovative detector program coupled to activities on the
experiment floor
– Leverage for XPCS and CXD detector development Learn from others’ mistakes and capitalize on several years of operational
experience at other 3rd generation coherence-based beamlines
– ESRF ID10 (XPCS) and APS 8-ID (XPCS) both originally built to satisfy broad scientific mission

8
Beamline Requirements
Coherent flux!
Stability
– Parasitically fluctuating signals contaminate XPCS time autocorrelation analysis
– Parasitically fluctuating signals significantly complicate phase retrieval
Beamtime
– Brilliance-hungry techniques so maximize the beamtime delivered to experimental stations
Long beamline
– High demagnification focusing for CXD and large Q XPCS
– Reduced flux density for radiation sensitive samples
Long small angle XPCS station
– “Smart” detectors likely to have larger pixels than today’s
Minimal energy tunability
– Above energy of large resonant enhancements

9
Design Philosophy
KISS – Keep it simple, stupid!
– Coherent flux• Select the coherent portion of the x-ray beam as far upstream as
possible to eliminate power mitigation issues downstream– Secondary source/pinhole
• Preserve the coherence delivered by the undulator and reduce parasitic scattering– Minimize the number of beamline optics
– Stability– Minimize the number of beamline optics
– Beamtime• Beam comprised of many horizontal coherence lengths—split the
beam and feed independent end stations
– Limited/infrequent energy tunability• Compatible with split beam operations

10
Conceptual Design-Secondary Source/Pinhole
Secondary source or pinhole
– Extract, in the horizontal, only a coherent fraction of the x-ray beam
Undulator
S1 S2
D1 D2
Sample
SecondarySource ( 27 m)
Pixel size = p

11
Conceptual Design-Secondary Source/Pinhole
Coherent diffraction over-sampling
– λD2/S2 > 2p
Far field
– S2/D2 > λ / S2
Coherent illumination
– S2 < λD1/S1
Use entire source
– 2σx < (S1 + S2) D0 / D1
Undulator
S1 S2
D1 D2
Sample
SecondarySource ( 27 m)
Pixel size = p
Item CXD, large Q XPCS Value
XPCS, CXDI Value
Max. sample to detector distance
3 m 10 m
S2 size 100 µm 30 µm
Maximum S1 secondary source size
80 µm 80 µm
Pixel resolution 20 µm 80 µm

12
Conceptual Design-Beam Splitting
2 secondary sources or pinholes in the FOE
– Multiplexed operation creates twice as much beamtime
– Small horizontal-bounce mirrors used to extract coherent fraction of the beam (in the horizontal)
– 2× mirror deflections and long beamline creates sufficient horizontal clearance
CXS FOE Beam Splitting Concept-Plan View
Hi-pass filter
Slit
Mirrors = secondary source or pinhole
½ Slit
WB Stop
ShutterWhite beam (WB)
Power-reducing aperture
Pink beam
12 mrad

13
Conceptual Design-Optical Layout
Simplified version of the optical layout
– Undulator• Future upgrade to tandem devices (rather than canted)
– Standard operating energy goal 12 keV• Low K value → less power• Less sample radiation damage
– High demagnification optics• Kinoform lenses or KB mirrors

14
Conceptual Design-Floor Layout
Stations
– Large Q XPCS and CXD station• High demagnification
optics• Diffractometer
– Small Q XPCS and CXDI station• Pinhole “SAXS”• Vertically focusing
optics
– SOE• Monochromators × 2• Optics?
– FOE

15
Conceptual Design-Small Q XPCS and CXDI Station Requirements
50 m from the source and 15 m long × 4 m wide
– Pinhole SAXS set-up
– 3 or more heavy-duty motorized support tables
1. High demagnification optics and collimating/guard apertures
– Vertical focusing to reduce the vertical coherence length
– Collimating and guard apertures
– All in vacuum where possible
2. Sample environment
– Flow cells
– In vacuum positioning
3. Long flight path and detector support assembly
– Smart detectors
– On-the-fly compression, on-board correlation

16
Conceptual Design-Large Q XPCS and CXD Station
Requirements 100 m from source and 6 m long × 6 m wide
– Optics table• High demagnification nanofocusing optics– KB mirror, kinoform lens, zone plate
– Large load capacity precision diffractometer and/or large load hexapod with ≤ 3 m detector arm
– Optical microscopy/fluorescence detectors for sample alignment and registration
– Small pixel, high dynamic range direct detection area detector
Alio Industries
Silicon kinoform lensK. Evans-Lutterodt et al., Opt. Express

17
Some Possible Issues for Discussion
Long beamline– Conceptual design only but significant rethinking required if not allowed
Mirrors or crystals for beam splitting Split beam vis-à-vis operational support
– Canted versus split beam beamlines Which “imaging” techniques, if any, belong as part of the beamline?
– Lensless imaging/ptychography/coherent diffractive imaging– Phase contrast imaging– Diffraction enhanced imaging
Vertical focusing further upstream– Large vertical correlation can not be used so eliminate from the start?
Energy gap– ≥ 7 keV for hard coherent x-ray scattering versus ≤ 2 keV for soft x-ray
coherent scattering/imaging Sample radiation damage Detectors, detectors, detectors!
– Now is the time to worry about detectors