94.5120_4300_ivs_6x6x8_int_submittal

2
NO. OF PUMPS: TAG: CAPACITY: USgpm (L/s) HEAD: ft (m) LIQUID: VISCOSITY: TEMPERATURE: °F (°C) SPECIFIC GRAVITY: PUMP DESIGN DATA MATERIALS OF CONSTRUCTION ANSI FLANGE RATING ANSI 125 ANSI 250 CONSTRUCTION BF DBF CASING CAST IRON DUCTILE IRON IMPELLER BRONZE BRONZE FLUSH LINE PUMP SHAFT 416 STAINLESS STEEL COUPLING HIGH TENSILE ALUMINUM GASKET CONFINED NON-ASBESTOS MAX. PUMP OPERATING CONDITIONS 175 psig at 140°F (12 bars at 60°C) 375 psig at 100°F (26 bars at 38°C) 100 psig at 300°F (7 bars at 149°C) 275 psig at 500°F (19 bars at 260°C) BRAIDED STAINLESS STEEL Page 1 of 2 SUBMITTAL JOB: ENGINEER: CONTRACTOR: REPRESENTATIVE: ORDER NO: SUBMITTED BY: APPROVED BY: DATE: DATE: DATE: MOTOR DESIGN DATA HP: FRAME SIZE: ENCLOSURE: VOLTS: HERTZ: 60 Hz PHASE: 3 EFFICIENCY: NEMA PREMIUM 12.12 FLANGE SIZE: SUCTION: DISCHARGE: COUPLING GUARD (NOT SHOWN) IS SUPPLIED. TOLERANCE OF ±0.125” (±3 mm) SHOULD BE USED. FOR EXACT INSTALLATION DATA PLEASE WRITE FACTORY FOR CERTIFIED DIMENSIONS. PUMP EQUIPPED WITH CASING DRAIN PLUG AND 1/4” NPT SUCTION AND DISCHARGE GAUGE PORTS Series 4300 IVS With Integrated Controls DRIVE DATA SENSORLESS CONTROL: MINIMUM SYSTEM PRESSURE TO BE MAINTAINED ft (m) * PROTOCOL (Standard): Modbus RTU Johnson® N2 Siemens® FLN ENCLOSURE: NEMA UL Type 12 EMI/RFI CONTROL: Integrated filter designed to meet EN61800-3 HARMONIC SUPPRESSION: Dual D-link reactors (Equivalent: 5% A line reactor) Supporting IEEE 519-1992 requirements** COOLING: Fan-cooled through back channel AMBIENT TEMPERATURE: -10°C to +45°C up to 1000 meters above sea level (-14°F to +113°F, 3300 ft) ANALOG I/O: 2 current or voltage inputs, 1 current output DIGITAL I/O: 6 programmable inputs (2 can be configured as outputs) PULSE INPUTS: 2 Programmable RELAY OUTPUTS: 2 Programmable COMMUNICATION PORT: 1-RS485, 1-USB PROTOCOL (Optional): LonWorks® BACnet™ MS/TP OPTIONS: Real-time Clock Relay Card General I/O FUSED DISCONNECT SWITCH: *If minimum maintained system pressure is not known: Default to 40% of design head **The IVS 102 drive is a low harmonic drive via built-in DC line reactors. This does not guaranty performance to any system wide harmonic specification or the costs to meet a system wide specification. If supplied with the system electrical details, Armstrong will run a computer simulation of the system wide harmonics. If system harmonic levels are exceeded Armstrong can also recommend additional harmonic mitigation and the costs for such mitigation. FILE NO: 94.5120 DATE: June 28, 2010 SUPERSEDES: 94.5120 DATE: Mar. 30, 2010 6 x 6 x 8 DIMENSION DATA - inches (mm) Frame RPM Power (HP) B C D E P S SD T XY Weight lbs (Kg) ODP TEFC ODP TEFC 1800 1200 1800 1200 9.75 (248) 7.50 (191) 13.50 (343) 19.50 (495) 33.00 (838) 10.38 (264) 213TC 7.5 3 7.5 3 14.17 (360) 12.13 (308) 29.76 (756) 471 (213.7) 486 (220.5) 215TC 10 5 10 5 14.17 (360) 12.13 (308) 29.76 (756) 481 (218.2) 501 (227.3) 254TC 15 -- 15 -- 14.88 (378) 13.38 (340) 34.70 (881) 531 (240.9) 571 (259.1) 256TC 20 -- 20 -- 14.88 (378) 13.38 (340) 34.70 (881) 550 (249.5) 620 (281.2) 6” (150 mm) 6” (150 mm)

Upload: sas999333

Post on 01-Jan-2016

32 views

Category:

Documents


3 download

DESCRIPTION

armstrong pump

TRANSCRIPT

Page 1: 94.5120_4300_IVS_6x6x8_Int_Submittal

NO. OF PUMPS:

TAG:

CAPACITY: USgpm (L/s) HEAD: ft (m)

LIQUID: VISCOSITY:

TEMPERATURE: °F (°C) SPECIFIC GRAVITY:

PUMP DESIGN DATA

MATERIALS OF CONSTRUCTION

ANSI FLANGE RATING ANSI 125 ANSI 250

CONSTRUCTION BF DBF

CASING CAST IRON DUCTILE IRON

IMPELLER BRONZE BRONZE

FLUSH LINE

PUMP SHAFT 416 STAINLESS STEEL COUPLING HIGH TENSILE ALUMINUM GASKET CONFINED NON-ASBESTOS

MAX. PUMP OPERATING CONDITIONS

175 psig at 140°F (12 bars at 60°C)

375 psig at 100°F (26 bars at 38°C)

100 psig at 300°F (7 bars at 149°C)

275 psig at 500°F (19 bars at 260°C)

BRAIDED STAINLESS STEEL

Page 1 of 2

SUBMITTAL

JOB:

ENGINEER: CONTRACTOR:

REPRESENTATIVE:

ORDER NO: SUBMITTED BY: APPROVED BY:

DATE: DATE: DATE:

MOTOR DESIGN DATA HP: FRAME SIZE: ENCLOSURE: VOLTS: HERTZ: 60 Hz PHASE: 3 EFFICIENCY: NEMA PREMIUM 12.12

FLANGE SIZE: SUCTION: DISCHARGE:

• COUPLING GUARD (NOT SHOWN) IS SUPPLIED. • TOLERANCE OF ±0.125” (±3 mm) SHOULD BE USED. • FOR EXACT INSTALLATION DATA PLEASE WRITE FACTORY FOR CERTIFIED DIMENSIONS. • PUMP EQUIPPED WITH CASING DRAIN PLUG AND 1/4” NPT SUCTION AND DISCHARGE GAUGE PORTS

Series 4300 IVS With Integrated Controls

DRIVE DATA SENSORLESS CONTROL: MINIMUM SYSTEM PRESSURE TO BE MAINTAINED ft (m) * PROTOCOL (Standard): Modbus RTU Johnson® N2 Siemens® FLN

ENCLOSURE: NEMA UL Type 12

EMI/RFI CONTROL: Integrated filter designed to meet EN61800-3 HARMONIC SUPPRESSION: Dual D-link reactors (Equivalent: 5% A line reactor) Supporting IEEE 519-1992 requirements** COOLING: Fan-cooled through back channel AMBIENT TEMPERATURE: -10°C to +45°C up to 1000 meters above sea level (-14°F to +113°F, 3300 ft) ANALOG I/O: 2 current or voltage inputs, 1 current output DIGITAL I/O: 6 programmable inputs (2 can be configured as outputs) PULSE INPUTS: 2 Programmable RELAY OUTPUTS: 2 Programmable COMMUNICATION PORT: 1-RS485, 1-USB

PROTOCOL (Optional): LonWorks® BACnet™ MS/TP

OPTIONS: Real-time Clock Relay Card General I/O FUSED DISCONNECT SWITCH:

*If minimum maintained system pressure is not known: Default to 40% of design head **The IVS 102 drive is a low harmonic drive via built-in DC line reactors. This does not guaranty performance to

any system wide harmonic specification or the costs to meet a system wide specification. If supplied with the system electrical details, Armstrong will run a computer simulation of the system wide harmonics. If system harmonic levels are exceeded Armstrong can also recommend additional harmonic mitigation and the costs for such mitigation.

FILE NO: 94.5120 DATE: June 28, 2010 SUPERSEDES: 94.5120 DATE: Mar. 30, 2010

6 x 6 x 8

DIMENSION DATA - inches (mm)

Frame RPM Power (HP)

B C D E P S SD T XY Weight lbs (Kg)

ODP TEFC ODP TEFC 1800 1200 1800 1200

9.75(248)

7.50(191)

13.50(343)

19.50(495)

33.00(838)

10.38(264)

213TC 7.5 3 7.5 3 14.17 (360) 12.13 (308) 29.76 (756) 471 (213.7) 486 (220.5) 215TC 10 5 10 5 14.17 (360) 12.13 (308) 29.76 (756) 481 (218.2) 501 (227.3) 254TC 15 -- 15 -- 14.88 (378) 13.38 (340) 34.70 (881) 531 (240.9) 571 (259.1) 256TC 20 -- 20 -- 14.88 (378) 13.38 (340) 34.70 (881) 550 (249.5) 620 (281.2)

6” (150 mm) 6” (150 mm)

Page 2: 94.5120_4300_IVS_6x6x8_Int_Submittal

S. A. Armstrong Limited 23 Bertrand Avenue Toronto, Ontario Canada, M1L 2P3 T: (416) 755-2291 F (Main): (416) 759-9101

Armstrong Pumps Inc. 93 East Avenue North Tonawanda, New York U.S.A. 14120-6594 T: (716) 693-8813 F: (716) 693-8970

Armstrong Integrated Limited Wenlock Way Manchester United Kingdom, M12 5JL T: +44 (0) 8444 145 145 F: +44 (0) 8444 145 146 © S.A. Armstrong Limited 2010

For Armstrong locations worldwide, please visit www.armstrongintegrated.com

SEAL DATA OPTIONS

OPTIONAL EQUIPMENT

SEE FILE NO. 43.50 FOR ENVIRONMENTAL ACCESSORIES

MECHANICAL SEAL DESIGN DATA

See File No. 43.50 for standard mechanical

Armstrong Seal Reference Number C1 (a) Other____________

CHASSIS SIZE:

hp VFD Chassis Size 200V-240V 380V-480V 600V

7.5 B1 A5 A5 10 B1 A5 A5 15 B1 B1 B1

BHP based onshown Fluid's sp. gr.

4300 IVS4380 IVS

4300 IVSAll Ratings

4380 IVSAll Ratings

CURVE NO.

PT107-1-0-1150

6x6x8

RPM

AVAILABILITY

SERIES

SIZE

1150

00.00

20012.62

40025.24

60037.85

80050.47

100063.09

(usgpm)(lps)

(0.0) 0

(1.5) 5

(3.0) 10

(4.6) 15

(6.1) 20

(7.6) 25

Head (m) ft

2 hp

3 hp

5 hp

1.5 hp

83

83

79

79

73

73

64

64%

5339

6.51 in

7.42 in

8.19 in

NPSHr

FlowWater, spgr= 1.0000

1150 RPM

NPSHr

84

BHP based onshown Fluid's sp. gr.

4300 IVS4380 IVS

4300 IVSAll Ratings

4380 IVSAll Ratings

CURVE NO.

PT107-1-0-1750

6x6x8

RPM

AVAILABILITY

SERIES

SIZE

1777/1750

00.00

40025.24

80050.47

120075.71

1600100.94

(usgpm)(lps)

(0.0) 0

(3.0) 10

(6.1) 20

(9.1) 30

(12.2) 40

(15.2) 50

(18.3) 60

(21.3) 70

Head (m) ft

7.5 hp

10 hp

15 hp

20 hp

83

83

79

79

72

72

64

64%

5239

6.65 in

7.29 in

8.19 in*

NPSHr

FlowWater, spgr= 1.0000

1777/1750 RPM

NPSHr

84