88050-3-en ax8 rym quick start web · the web interface also provides access to other features and...

2
Quick Start Guide http://www.raymarine.com/manuals Obtain the complete documentation for your product The supplied printed documentation is a subset of the full documentation available for your product. Important: The latest versions of all English and translated handbooks are available on the Raymarine website. Please check the website to ensure you have the latest and complete documentation and safety information for your product. Connections to a Raymarine MFD The AX8 can be powered using the supplied PoE injector, alternatively, it can also be powered by a Raymarine MFD / network switch capable of providing power over ethernet (PoE). Up to 8 AX8 cameras can be networked together. Raymarine LightHouse MFD with PoE Raymarine LightHouse MFD Class 2 PoE device 12 V / 24 V dc 12 V / 24 V dc 12 V / 24 V dc 12 V / 24 V dc Raymarine LightHouse MFD Max. x8 55 mm (2.17 in) 25.6 mm (1.00 in) 80 mm (3.15 in) 13.5 mm (0.53 in) LED Camera IR Ethernet and PoE 25.6 mm (1.00 in) Reset Ethernet Diagnostics LED Power Diagnostic LED 60 mm (2.36 in) 125 mm (4.33 in) Surface mounting holes 106 mm (4.17 in) 14 mm (0.55 in) Camera fixing 68 mm (2.68 in) FLIR Ram mount 47 mm (1.85 in) 7 mm (0.28 in) 20 mm (0.79 in) 5 mm (0.20 in) 12 mm (0.47 in) 37 mm (1.46 in) 52 mm (2.05 in) Powered by PoE injector 12 V / 24 V dc Class 2 PoE device 88050-3-EN 09-2015 Date: Document number: Software requirements: Your Raymarine Multifunction display must be running LightHouse TM II Release 15.xx or greater. http://www.raymarine.com/- software Set-up The AX8's built-in web interface MUST be used to align the thermal and visible images before using Thermal MSX ® mode and to set-up spot alarms. The web interface also provides access to other features and settings not available on your MFD. Connect the AX8 to your MFD network and ensure it is powered. When using the camera in Thermal MSX ® mode, you can use the "Adjust Distance" slider control in the web interface to adjust the overlay position of the visible Vs. the thermal image. Raymarine LightHouse MFD Powered by PoE injector 12 V / 24 V dc Class 2 PoE device Obtain the AX8's IP address, this can be found by accessing the AX8's diagnostics page using a Raymarine LightHouse MFD. Homescreen > Set-up > Maintenance > Diagnostics > Select Device > AX8. Scroll down to Networks, the IP address is part of the RTSP URL. EXAMPLE rtsp://10.22.0.32/avc Select the Spot alarm icon to add a new spot to the image, drag the spot to the required position and then set the temperature alarm by selecting the bell icon. PC / Smartphone / tablet Wi-Fi Connect your PC or smart device to the MFD network. For information on connecting a PC or smart device to your Raymarine MFD network, refer to the LightHouse Operation instructions (81360). Refer to the FLIR AX Series user manual (T559913), available on the supplied CD for full details of the features and settings available from the web interface. EXAMPLE Default logon: Username: admin Password: admin Enter the AX8's IP address in the web browser's address bar on your conntected PC or smart device. To obtain the AX8's IP address using a PC download and install the FLIR IP Config tool version 1.9 or greater. http://tinyurl.com/o5wudd7 Alternatively you can connect the AX8 directly to a PC using an ethernet (RJ45) cable. 5 1 2 3 4 6 Potential ignition source The PoE injector is NOT approved for use in hazardous/ flammable atmospheres. Do NOT install in a hazardous/ flammable atmosphere (such as in an engine room or near fuel tanks). In this scenario, you can use a female to male RJ45 adapter cable (available separately) to extend the cable run between the AX8 and the PoE injector.

Upload: others

Post on 09-May-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 88050-3-EN AX8 RYM Quick start WEB · The web interface also provides access to other features and settings not available on your MFD. Connect the AX8 to your MFD network and ensure

Quick Start Guide

http://www.raymarine.com/manuals

Obtain the complete documentation for your productThe supplied printed documentation is a subset of the full documentation available for your product.

Important: The latest versions of all English and translatedhandbooks are available on the Raymarine website. Please check thewebsite to ensure you have the latest and complete documentation and safety information for your product.

Connections to a Raymarine MFDThe AX8 can be powered using the supplied PoE injector, alternatively, it can also be powered by a Raymarine MFD / network switch capable of providing power over ethernet (PoE).

Up to 8 AX8 cameras can be networked together.

Raymarine LightHouse MFD with PoE

Raymarine LightHouse MFD

Class 2 PoE device 12 V / 24 V dc 12 V / 24 V dc 12 V / 24 V dc 12 V / 24 V dc

Raymarine LightHouse MFD

Max.x8

55 mm (2.17 in)

25.6

mm (1

.00 in

)80

mm

(3.15

in)

13.5 mm(0.53 in)

LED

Camera

IR

Ethernet and PoE

25.6 mm (1.00 in)

Reset

EthernetDiagnostics LED

PowerDiagnostic LED

60 mm (2.36 in)

125 m

m (4

.33 in

)

Surfa

ce m

ounti

ng ho

les 10

6 mm

(4.17

in)

14 mm(0.55 in)

Came

ra fix

ing 68

mm

(2.68

in)

FLIR

Ram

mou

nt47

mm

(1.85

in)

7 mm(0.28 in)

20 m

m(0

.79 in

)

5 mm(0.20 in)

12 mm(0.47 in)

37 m

m (1

.46 in

)

52 m

m (2

.05 in

)

Powered by PoE injector12 V / 24 V dc

Class 2 PoE device

88050-3-EN09-2015Date:

Document number:

Software requirements: Your Raymarine Multifunction display must be running LightHouseTM II Release 15.xx or greater.http://www.raymarine.com/-software

Set-upThe AX8's built-in web interface MUST be used to align the thermal and visible images before using Thermal MSX® mode and to set-up spot alarms. The web interface also provides access to other features and settings not available on your MFD.

Connect the AX8 to your MFD network and ensure it is powered.

When using the camera in Thermal MSX® mode, you can use the "Adjust Distance" slider control in the web interface to adjust the overlay position of the visible Vs. the thermal image.

Raymarine LightHouse MFD

Powered by PoE injector

12 V / 24 V dcClass 2 PoE device Obtain the AX8's IP address, this can be found

by accessing the AX8's diagnostics page using a Raymarine LightHouse MFD.Homescreen > Set-up > Maintenance > Diagnostics > Select Device > AX8.Scroll down to Networks, the IP address is part of the RTSP URL.

EXAMPLE

rtsp://10.22.0.32/avc

Select the Spot alarm icon to add a new spot to the image, drag the spot to the required position and then set the temperature alarm by selecting the bell icon.

PC / Smartphone / tablet

Wi-Fi

Connect your PC or smart device to the MFD network. For information on connecting a PC or smart device to your Raymarine MFD network, refer to the LightHouse Operation instructions (81360).

Refer to the FLIR AX Series user manual (T559913), available on the supplied CD for full details of the features and settings available from the web interface.

EXAMPLE

Default logon:Username: admin Password: admin

Enter the AX8's IP address in the web browser's address bar on your conntected PC or smart device.

To obtain the AX8's IP address using a PC download and install the FLIR IP Config tool version 1.9 or greater. http://tinyurl.com/o5wudd7

Alternatively you can connect the AX8 directly to a PC using an ethernet (RJ45) cable.

5

1

2

3

4

6

Potential ignition source

The PoE injector is NOT approved for use in hazardous/flammable atmospheres. Do NOT install in a hazardous/flammable atmosphere (such as in an engine room or near fuel tanks). In this scenario, you can use a female to male RJ45 adapter cable (available separately) to extend the cable run between the AX8 and the PoE injector.

Page 2: 88050-3-EN AX8 RYM Quick start WEB · The web interface also provides access to other features and settings not available on your MFD. Connect the AX8 to your MFD network and ensure

1 2 3 4 5 6B

1 2 3C

1 2 4A 3 5

Visible

LED lightSwitch the camera's LED light on and off directlyfrom your Raymarine MFD's Camera application menu: Menu > Adjust > Light.

AlarmsEnable AX8 spot alarms on your Raymarine MFD.(Spot alarms MUST be set-up using the AX8's web interface.)

Mounting optionsAll mounting options require the supplied cooling bracket to be fitted to the AX8 before installation.A) Bracket mounting (using optional Raymarine accessory R70375) ; B) RAM® mounting (using optional FLIR accessory 261-2288-00) ;C) Surface mounting.

Important: Before mounting the camera check the desired location, ensuring thatthe area or objects to be monitored are within the camera's field of view and that any spot alarms are correctly placed.

Consider using the FLIR ONETM to survey the best location for your AX8 prior to installation.

Operations / Monitoring Monitor feeds and spot readingsusing the Camera application

Important: Refer to the LightHouseTM MFD operation instructions (81360) for details on operating your AX8 using your Raymarine Multifunction Display (MFD). Visit the website to download the document.

Switch image mode directly from your Raymarine MFD's Camera application menu.

Optional RAM®

Mounting

FLIR Part number:261-2288-00

SurfaceMounting

OptionalBracketMounting

Raymarine Part number:R70375

Note:Disregard the bolt supplied withR70375 and use the 1/4" 20 x 30 mm Hex bolt supplied with the AX8 camera.

Thermal MSX® Thermal

Raymarine LightHouse MFD

http://www.raymarine.com/manuals

http://www.flir.com/flirone/

Caution:To prevent possibledamage to the camerahousing, do NOT over-tighten the screws whensecuring the coolingbracket.

Caution:To prevent possibledamage to the camerahousing, do NOT over-tighten the screws whensecuring the coolingbracket.

Caution:To prevent possibledamage to the camerahousing, do NOT over-tighten the screws whensecuring the coolingbracket.

Note:Disregard the bolts supplied with261-2288-00 and use the 10–32UNF 1/2” hex bolts supplied with the AX8 camera.

Selecting the image mode