77012794_a elec.pdf
TRANSCRIPT
-
8/11/2019 77012794_A ELEC.pdf
1/6
TABLE OF CONTENTS
SHEET
CONTENTS AND INDEX LISTMAIN CABINETS WIRINGEMERGENCY STOP BUTTON OF CTRL PANELSPOWER SUPPLY OF CONTROL SYSTEMEXTERNAL PUMP BUTTON1-BOOM HOLDING MAGNETS
CONTENTS REVISION INFOREVISION
123456
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
CHECKED
APPROVED
DRAWN BY
DATE NAME 1 / 6
3-77012794-A2006-09-03 PLE
AXERA 5 THC560 CONTROL SYSTEM
29 30
CONTROL_
CONTROL CIRCUIT DIAGRAM CONTENTS AND INDEX LIST2006-09-03 PCH
2006-09-03 AP 1JB102 77012794POSITION
SHEET
DWG NR
ID-CODECopyright Sandvik Mining and Construction prior written consent of Sandvik.
SANDVIK
of subject matter thereof without theany third party or used in manufacturenot be copied, reproduced, disclosed toreturned on request. The document mustproperty of Sandvik and it must beNOTICE! This document is the exclusive
-
8/11/2019 77012794_A ELEC.pdf
2/6
1 W
S1
9 0
2 x1
. 5
7 x
0 . 5
+ C
W4 2
1 S1 9 0
H O
RAMETR
E FRAPPE
PER
C U S S
I
ON H
O U
RMETER
1 W
S 8
1
4 x
0 . 7 5
+ C
1 S 8 1
LIMITE A
RRIERE
REAR LIM
IT
SEN
S O
R
1 WY4
7
ELECTRICAL SWITCHGEAR
MP
ARMOIRE PRINCIPALE
1THC
QN
SW
1JB102
1 X1
0 2
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
CHECKED
APPROVED
DRAWN BY
DATE NAME 2 / 6
3-77012794-A2006-09-03 PLE
AXERA 5 THC560 CONTROL SYSTEM
CONTROL_
CONTROL CIRCUIT DIAGRAM MAIN CABINETS WIRING2006-09-03 PCH
2006-09-03 AP 77012794POSITION
SHEET
DWG NR
ID-CODECopyright Sandvik Mining and Construction prior written consent of Sandvik.
SANDVIK
of subject matter thereof without theany third party or used in manufacturenot be copied, reproduced, disclosed toreturned on request. The document mustproperty of Sandvik and it must beNOTICE! This document is the exclusive
3 x
0 . 7 5
1 Y4 7
VALVE DE
RET
O U
R RAPIDE
RAPID M
O
VEMENT BA
CK
S O
LEN
OID
WY4
0
3 x
0 . 7 5
Y4 0
O U
VERT
UR
E PIN
CE ME
CHE
( O
PTI
ON
)
R O
D
CLAM
P O
PENED
( O
PTI
ON
)
WY4 1
3 x
0 . 7 5
Y4 1
FERMET
UR
E PIN
CE ME
CHE
( O
PTI
ON
)
R O
D
CLAM
P C
L O S
ED
( O
PTI
ON
)
1 W
S1 2
6
2 x1
. 5
1 S1 2 6
1W102
1 W
9
4
1 W
9
3
3 x1
. 5
5 0
x1
AM
ORTI
S S
EMENT
STABILAT
OR
( O
PTI
ON
)
PRE
S S . S
W
. ( O
PTI
ON
)
36x1.5
1 W
S 8 0
4 x
0 . 7 5
+ C
1 S 8 0
LIMITE A
VANT
FR
ONT LI
MIT
SEN
S O
R
pp
-
8/11/2019 77012794_A ELEC.pdf
3/6
P O
W E R P A
C K
S T A R T -
S T
O P
S W I T
C H
C O
M M
U T A T E
U R
M A R
C H E -A R R E T
P O
W E R P A
C K
11
X500 X500X500
1X102 1X1021X102
1X1 1X1 1X1
1
526 506577
A1
A1
1
10 S
SH501
2.1 1.3
2 3
A3
A3
A2
A2
1.42.2SH5011S771S77
1.3
1.4
2.1
2.2
10 S
1SH78
2.1 1.3
1.42.21SH78
X110 1X110 1X110
1X1 1X1 1X1
1X102 1X102 1X102
1X94 1X94 1X94
17
0 S
SH502
131 130
A4
2.1 1.3
1.42.2SH502
X500
A4
A6
A6
A5
A5
4 6 5
4
4
6
6
5
5
B O U
T O
N A R R E T
D
U R
G E N
C E
P O S
T E
O P E R A T E
U R
E M E R
G E N
C Y
S T
O P
B U
T T
O N
O F
C O
N T R
O L P A N E L
X500 X500 X500512 511510 509 513X500
2.1
S505 2.2
1X102 1X102
C O
M M A N D E A
U T
O /
M A N
U
P O
M P E A E A
U
W A T E R P
U M P
C O
N T R
O L
A U
T O /
M A N
U A L
U S
E
P R E
S S U
R E
S W I T
C H
R E
S E T
C O
M P R E
S S O
R
C O
N T R
O L
A U
T O /
M A N
U
U S
E
C O
M M A N D E A
U T
O /
M A N
U
C O
M P R E
S S
E U
R
R E M I
S E A Z E R
O
P R E
S S O S
T A T
S
1X102 1X102 1X102
1X1 1X1 1X1 1X1 1X1
1X94 1X94 1X94 1X94 1X94 1X94 1X94 1X94
17 18 19 20 21
C E N T R A L E D E
G R A I
S S
A G
E
( O
P T I
O N
)
C E N T R A L
G R E A
S I N
G
U N I T
C O
N T R
O L
( O
P T I
O N
)
X500 X500 X500573 574 501
1X102 1X102 1X102
1X1 1X1 1X1
1X94 1X94 1X9411
2
2
3
3
B7
B7
17
17
B8
B8
18
18
B9
B9
19
19
B10
B10
20
20
C1
C1
21
21
C2
C2
22
22
22
C3
C3
23
23
23
C4
C4
24
24
24
MP
1JB94
1JB102
12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
CHECKED
APPROVED
DRAWN BY
DATE NAME 3 / 6
3-77012794-A2006-09-03 PLE
AXERA 5 THC560 CONTROL SYSTEM
CONTROL_
CONTROL CIRCUIT DIAGRAM EMERGENCY STOP BUTTON OF CTRL PANELS2006-09-03 PCH
2006-09-03 AP 1JB102 77012794POSITION
SHEET
DWG NR
ID-CODECopyright Sandvik Mining and Construction prior written consent of Sandvik.
SANDVIK
of subject matter thereof without theany third party or used in manufacturenot be copied, reproduced, disclosed toreturned on request. The document mustproperty of Sandvik and it must beNOTICE! This document is the exclusive
1W102 01 1W102 02 1W102 03 1W102 04 1W102 051W102 061W102 17 1W102 18 1W102 19 1W102 20 1W102 21 1W102 24
1W94 01 1W94 02 1W94 03 1W94 04 1W94 051W94 061W94 17 1W94 18 1W94 19 1W94 20 1W94 21 1W94 22 1W94 23 1W94 24
SH501SH5021S78
4
0
2
1
3
S
1
STOP
RUNNING
START
1 2
-
8/11/2019 77012794_A ELEC.pdf
4/6
1X1
1X1 12
MP-1X1101X102
1/7105/11
1X1
1X1
1THC-1S190
13
14
B1B1124
D I
S J O
N C
T E
U R
S
D E L A R M
O I R E
P R I N
C I P A L E
C O
N T R
O L F
U S
E S
O F M A I N
S W I T
C H
G E A R
H O
R A M E T R E
F R A P P E
P E R
C U S S
I O
N
H O U
R M E T E R
1/702
WY40
13
14
1WS190 01
1WS190 02
1
11
2MP-F451.1
10AMP-1X110
MP-X450
MP-1X110
121
122
A10A10
A7 A 7
B2B2501
F451.2
1X102
1X102
1X102
B3 B 31X102
1X102B4 B 4
+24VDC
MAIN PANEL POWER SUPPLY
-0VDC
5/11
1/8
KVL
SLU
MP-X500 1V582K
ALTERNATIVE S
MP-X5001X102
A9A9557
MP-X5001X102
A8A8584
5/11
YE = YELLOW
BK = BLACK
RD = RED
TR = TRANSPARENT
Y/G = YEL/GREGR = GREEN
WH = WHITE
VI = VIOLET
BR = BROWN
PK = PINK
BU = BLUE
GY = GRAY
COLOURS
MP-X500
MP
12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
CHECKED
APPROVED
DRAWN BY
DATE NAME 4 / 6
3-77012794-A2006-09-03 PLE
AXERA 5 THC560 CONTROL SYSTEM
CONTROL_
CONTROL CIRCUIT DIAGRAM POWER SUPPLY OF CONTROL SYSTEM2006-09-03 PCH
2006-09-03 AP 1JB102 77012794POSITION
SHEET
DWG NR
ID-CODECopyright Sandvik Mining and Construction prior written consent of Sandvik.
SANDVIK
of subject matter thereof without theany third party or used in manufacturenot be copied, reproduced, disclosed toreturned on request. The document mustproperty of Sandvik and it must beNOTICE! This document is the exclusive
1X94 1616
16
1JB94
1X941X94
Y41BR
1
BU
2
37
3
4
3
4
4 24
2
S534S534
37
38
38
1X1 1X137 38
Y40BR
1
BU
2
1W102 07
1W102 08
1W102 09
1W102 10
1W102 11
1W102 12
1W102 13
1W102 14
BR
WY40 BU
WY41 BR
WY41 BU
1W94 16
1W94 381W94 37
R O
D
C L A M P
P I N
C E M E
C H E
p
-
8/11/2019 77012794_A ELEC.pdf
5/6
X500 544
11
X500 539 X500 X500
01 210 S 1.3
1.4
1X102 1X102
S503
1X102
2.1
2.2
1.3
1.4
T E
S T P
O M P E
E X T E R N E
( O
P T I
O N
)
S504
X500
P O
M P E E X T E R N E
( O
P T I
O N
)
E X T E R N A L P
U M P
( O
P T I
O N
)
X500547 546541 537 X500 508
E X T E R N A L P
U M P
T E
S T
( O
P T I
O N
)
1X1 26 1X1 27 1X1 28 1X1 1X1 1X129 30 31 321X1
S504
1X102 1X102 1X102 1X102C6
C6
C7
C7
C8
C8
C9
C9
C10
C10
D1
D1
D2
D2
1X94 1X94 1X94 1X94 1X94 1X94 1X942626
27
27
28
28
29
29
30
30
31
31
32
32
S503 S504
12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
CHECKED
APPROVED
DRAWN BY
DATE NAME 5 / 6
3-77012794-A2006-09-03 PLE
AXERA 5 THC560 CONTROL SYSTEM
CONTROL_
CONTROL CIRCUIT DIAGRAM EXTERNAL PUMP BUTTON2006-09-03 PCH
2006-09-03 AP 77012794POSITION
SHEET
DWG NR
ID-CODECopyright Sandvik Mining and Construction prior written consent of Sandvik.
SANDVIK
of subject matter thereof without theany third party or used in manufacturenot be copied, reproduced, disclosed toreturned on request. The document mustproperty of Sandvik and it must beNOTICE! This document is the exclusive
1W102 26 1W102 27 1W102 28 1W102 29 1W102 30 1W102 31 1W102 32
1JB94
MP
1 W9 4 2 6 1 W9 4 2 7 1W 94 2 8 1 W9 4 2 9 1 W9 4 3 0 1 W9 4 3 1 1W 94 3 2
2.1
2.2
S503
4
0
2
1
3
S
1
STOP
RUNNING
START
S504
4
2
2
0
3
1
1
2 11 2
-
8/11/2019 77012794_A ELEC.pdf
6/6
43
1X1 106
5
87
1K70 1K71 1K72
TMS DD/DDS/DDSS OPTION
1S80
BR
1
BU
2
1Y47
1S81
HOLDING MAGNETS OF THE JOYSTICKS
2 3
1
2 3
1 /702
3/30
1
1S126
1K71
3/30
1/710
ELECTRO-AIMANTS DE MAINTIEN DES JOYSTICKS
11
1K74
1K74
W42
V O
Y A N T D E B I T
H U
I L E
S L
U
( O
P T I
O N
)
AM
A1
A2
1K73
1K73
ONLY IF
SL
U
I S
N
OT
1/83/30
A1
A2
S L
U
O I L F L
O W
I N D I
C A T
O R L I
G H T
( O
P T I
O N
)
P R E
S S O S
T A T
A M
O R T I
S S
E M E N T
S T A B I L A T
O R
P R E
S S . S
W .
( O
P T I
O N
)
29
B
1S73 1S73
13
1S73
28
1.3
1K73
20
31
QN-1H72
11
11
12 14
12 14
1.4
1K74
1X9410
ONL
Y IF
STAB
.
I S
N OT
01
W42 07
13
D E B I T H
U I L E
S L
U
S L
U
O I L F L
O W
( O
P T I
O N
)
P O U S S
E E
F R A P P E
2
24VDC
1 1 2
3 3 3
1X94
10
9
7
1
12
71X1
BK
BK
81X1
1XV1
10
1X94
RETURN AUTOM=OFFA=RETURN AUTOB=FORCED RETURN
1X1
2.1
BK
2.2
R O
T A T I
O N
F E E D
BK
1S721S711S70
91X1
P E R
C U S S
I O
N
91XV5
1JB93-1X1
1JB93-1X1
+1THC
1JB93-1X1
1JB93-1X1
1JB93-1X1
BK
BK
BK
BK
BK
BK
BK
BK
1JB93-1X1
R O
T A T I
O N
7
9
1X1 11
1K70
1K72
25
27
23
L I M I T E A R R I E R E
B A
C K L I M I T
L I M I T E A V A N T
F R
O N T L I M I T
4 2
3 1
XXX
M
A
B
13
14
15
18 16
11
14 12
11
14 12
1K70 1K71 1K72
A1
A2
A1
A2
A1
A2
Y1
DP-BOX
1X1 16
1XV2
1XV41XV3
192315
1JB94
0.2s
1K70 Settings:Multi timer -> Range= 0.1-1s -> Setting= 2
-> Function= C
12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
CHECKED
APPROVED
DRAWN BY
DATE NAME 6 / 6
3-77012794-A2006-09-03 PLE
AXERA 5 THC560 CONTROL SYSTEM
CONTROL_
CONTROL CIRCUIT DIAGRAM 1-BOOM HOLDING MAGNETS2006-09-03 PCH
2006-09-03 AP 1JB102 77012794POSITION
SHEET
DWG NR
ID-CODECopyright Sandvik Mining and Construction prior written consent of Sandvik.
SANDVIK
of subject matter thereof without theany third party or used in manufacturenot be copied, reproduced, disclosed toreturned on request. The document mustproperty of Sandvik and it must beNOTICE! This document is the exclusive
1W93 01 1W93 02
1W93 03
1W94 07
1W94 09 1W94 10
1WY47 BR
1WS126 02
1WY47 BU
1WS126 01
1WS80 01
1WS80 03 1WS81 03
1WS81 01
2 2
p
1214 11
p
1214 11
p
1214 11
1214 11
1618 15