6.6 pressure sensor

3
www.distech-controls.com PDIGR-LP2 Series Low Pressure Transducers Overview The PDIGR-LP2 Series are low pressure transducers. These devices can be used to measure positive, negative or differential pressure in the ranges of 1”W.C. to 12”W.C. (200 to 2000Pa). The piezoresistive sensor is ideal for monitoring the pressure of air or other clean inert gases and is limited only to those media which will not attack polyetherimide, silicon, fluorosilicone, silicone, EPDM and neoprene seals. The PDIGR-LP2 Series features field selectable pressure ranges and output signal types for the most flexible applications. The output signal is factory calibrated and temperature compensated for highest startup accuracy and trouble-free operation. Available options include LCDs and integrated static pressure probes. This product offers a cost effective solution for customers who wish to have ease of installation to their Building Automation System. Applications Used for monitoring filters. Used for measuring duct static pressure. Used for measuring velocity pressure. Features & Benefits Attractive enclosures are well received by architects and building owners Economical Optional LCD Optional integrated pressure probe Accurate pressure monitoring for increased comfort Functional weather resistant ABS enclosure 24V AC/DC power supply is standard Field selectable pressure ranges and output signals Models with ranges in Pascals

Upload: javier-morales-cabello

Post on 13-Apr-2015

81 views

Category:

Documents


7 download

TRANSCRIPT

www.distech-controls.com

PDIGR-LP2 Series Low Pressure Transducers

Overview

The PDIGR-LP2 Series are low pressure transducers. These devices can be used to measure positive, negative or differential pressure in the ranges of 1”W.C. to 12”W.C. (200 to 2000Pa). The piezoresistive sensor is ideal for monitoring the pressure of air or other clean inert gases and is limited only to those media which will not attack polyetherimide, silicon, fluorosilicone, silicone, EPDM and neoprene seals.

The PDIGR-LP2 Series features field selectable pressure ranges and output signal types for the most flexible applications. The output signal is factory calibrated and temperature compensated for highest startup accuracy and trouble-free operation. Available options include LCDs and integrated static pressure probes.

This product offers a cost effective solution for customers who wish to have ease of installation to their Building Automation System.

Applications

Used for monitoring filters.

Used for measuring duct static pressure.

Used for measuring velocity pressure.

Features & Benefits

Attractive enclosures are well received by architects and building owners

Economical

Optional LCD

Optional integrated pressure probe

Accurate pressure monitoring for increased comfort

Functional weather resistant ABS enclosure

24V AC/DC power supply is standard

Field selectable pressure ranges and output signals

Models with ranges in Pascals

PDIGR-LP2 Series

www.distech-controls.com

Product Warranty & Total Quality Commitment

Distech Controls PDIGR-LP2 Series product line is built to meet rigorous quality standards and carries a five-year warranty. Distech Controls is an ISO 9001 registered company. Distech Controls’ products provide both the contractor and the end user with the flexibility of using “best-of-breed” products in system design.

Available Low Pressure Transducer Models

PDIGR-LP2Ayy Low Pressure Transducer

- Monitor duct static pressure, static pressure across filters

- ABS Enclosure

PDIGR LP2AyyS Low Pressure Transducer with Integrated Static Pressure Probe

- Monitor Duct static pressure, static pressure across filters

- ABS Enclosure

PDIGR-LP2Byy Low Pressure Transducer with LCD

- Monitor Duct static pressure, static pressure across filters

- ABS Enclosure

PDIGR-LP2ByyS Low Pressure Transducer with Integrated Static Pressure Probe and LCD

- Monitor Duct static pressure, static pressure across filters

- ABS Enclosure

Model Options yy – Pressure Range Option

Related Products

Pitot/Static Tubes

HFO-0016 7.5” aluminum pitot tube

HSO-0016 7.5” aluminum static tube

HFO-0016-K Two 7.5” aluminum pitot tubes c/w 6’ pneumatic tubing

HSO-0016-K 7.5” aluminum static tube c/w 3’ pneumatic tubing

Flow Sensors

SSS-1002 Differential pressure flow sensor 4” ABS

SSS-1003 Differential pressure flow sensor 6” ABS

SSS-1004 Differential pressure flow sensor 8” ABS

SSS-1005 Differential pressure flow sensor 10” ABS

Calibration

PDIGR-LP2-NST NIST calibration certificate

For more information on these or other Distech Controls products please refer to our web site at www.distech-controls.com or contact [email protected].

*05DI-DSLP2XX-10*

05DI-DSLP2XX-10

PDIGR-LP2 Series

www.distech-controls.com

Product Specifications

Environmental Electrical

Operating Temperature: 0oC to 60

oC; 32

oF to 140

oF Input Power: 12 to 28Vac; 15 to 35Vdc (non isolated half

Storage Temperature: 0oC to 70

oC; 32

oF to 158

oF wave rectified)

Relative Humidity: 10 to 90% Non-condensing Supply Current @ 24Vdc: < 4mA

Enclosure Output: User selectable:

Material: High impact ABS, plenum rated with optional 4-20mA (2 wire), 0-5Vdc and 0-10Vdc (3 wire)

gasket around cover Accuracy: ±1% F.S.O.

Color: Black Long Term Stability: < ± 1% F.S.O. per year

Dimensions (overall): 4.55” x 3.30” x 2.10” (111mm x 84mm x 53mm) Thermal Effects: < ± 3% F.S.O. over compensated range

Shipping Weight: Input Voltage Effects: Negligible over specified operating range

- PDIGR-LP2Ayy 0.45lbs (0.99kg) Current Drive Capability: 400 ohms maximum @ 24Vdc

- PDIGR-LP2AyyS 0.60lbs (1.32kg) Voltage Drive Capability: 2kΩ minimum for 0-5Vdc signal

- PDIGR-LP2Byy 0.50lbs (1.10kg) 10kΩ minimum for 0-10Vdc signal

- PDIGR-LP2ByyS 0.65lbs (1.43kg) Protection Circuitry: Reverse voltage protected and output limited

Pressure Connections: Barbed ports for 0.17" (4.3mm) ID flexible tubes Response Time: 1ms maximum

Wiring Connections: Screw terminal block (14 to 22 AWG) Zero Adjust: Push button auto-zero

Elec. Conduit Connection: Access hole for ½" NPT conduit or cable gland Pressure

Temp. compensated range: 10°C to 50°C; 50°F to 122°F Over Pressure: 20 psi or 2X range (whichever is greater)

Media Compatibility: Limited only to those that will not attack Pressure Ranges: 00 - ±0.5", ±1.0", 0-1.0", 0-2.0" W.C.

polyetherimide, silicon, fluorosilicone, EPDM 01 - ±1.5", ±3.0", 0-3.0", 0-6.0" W.C.

and neoprene seals. Typically dry air or inert 02 - ±2.0", ±4.0", 0-4.0", 0-8.0" W.C.

gas, but liquid is allowed. 03 - ±2.5", ±5.0", 0-5.0", 0-10.0" W.C.

Agency Approvals 04 - ±3.0", ±6.0", 0-6.0", 0-12.0" W.C.

Material1: UL94-VB 05 - ±100, ±200, 0-200 / 0-400 Pa

06 - ±250, ±500, 0-500 / 0-1000 Pa

07 - ±400, ±800, 0-800 / 0-1600 Pa

08 - ±500, ±1000, 0-1000 / 0-2000 Pa

Electromagnetic Compatibility

1. All materials and manufacturing processes comply with the RoHS directive .

Specifications subject to change without notice. Distech Controls logo is a trademark of Distech Controls Inc.; All other trademarks are property of their respective owners.