4.14.2010 team ii: b | c | w f… · 4.14.2010 team ii: bonfanti | clarke | cox | wiacek 2 building...

158
TEAM II: BONFANTI | CLARKE | COX | WIACEK 4.14.2010 1

Upload: others

Post on 02-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 1

Page 2: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 2

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Building Overview

Page 3: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 3

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Building Overview

Page 4: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 4

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Building: 52 story office building with ground floor retail

1.5 Million SF

Location: 8th Avenue & 41st Street, Manhattan

Statistics and Project TeamBuilding Overview

Page 5: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 5

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Building: 52 story office building with ground floor retail

1.5 Million SF

Location: 8th Avenue & 41st Street, Manhattan

Cost: Approximately $1 Billion (2007)

Statistics and Project TeamBuilding Overview

Page 6: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 6

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Building: 52 story office building with ground floor retail

1.5 Million SF

Location: 8th Avenue & 41st Street, Manhattan

Cost: Approximately $1 Billion (2007)

Architect: Renzo Piano Building Workshop

FXFowle

Gensler (Interiors)

Statistics and Project TeamBuilding Overview

Page 7: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 7

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Building: 52 story office building with ground floor retail

1.5 Million SF

Location: 8th Avenue & 41st Street, Manhattan

Cost: Approximately $1 Billion (2007)

Architect: Renzo Piano Building Workshop

FXFowle

Gensler (Interiors)

Engineer: Thornton Tomasetti

Flack + Kurtz

Statistics and Project TeamBuilding Overview

Page 8: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 8

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Building: 52 story office building with ground floor retail

1.5 Million SF

Location: 8th Avenue & 41st Street, Manhattan

Cost: Approximately $1 Billion (2007)

Architect: Renzo Piano Building Workshop

FXFowle

Gensler (Interiors)

Engineer: Thornton Tomasetti

Flack + Kurtz

CM: Amec (Core + Shell)

Turner (Interiors)

Statistics and Project TeamBuilding Overview

Page 9: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 9

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Building Overview

Page 10: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 10

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Configuration of SpacesBuilding Overview

Page 11: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 11

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Configuration of Spaces

Podium

Building Overview

Page 12: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 12

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Configuration of Spaces

Podium

Tower

Building Overview

Page 13: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 13

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Configuration of SpacesBuilding Overview

Page 14: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 14

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Configuration of SpacesBuilding Overview

Owner Occupancy:

2-27, Podium The New York Times

Page 15: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 15

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Building Overview Configuration of Spaces

Owner Occupancy:

2-27, Podium The New York Times

29-50 Forest City Ratner Companies

Page 16: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 16

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Configuration of SpacesBuilding Overview

Owner Occupancy:

2-27, Podium The New York Times

29-50 Forest City Ratner Companies

27, 51 Jointly-owned MEP spaces

Page 17: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 17

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

[Image: nytimes.com]

Owner Occupancy:

2-27, Podium The New York Times

29-50 Forest City Ratner Companies

27, 51 Jointly-owned MEP spaces

Jointly-owned Cogeneration plant

Configuration of SpacesBuilding Overview

Page 18: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 18

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Team Workflow

Page 19: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 19

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Design Phase

Structural

Mechanical

Lighting/ Electrical

Construction

Team Workflow

Page 20: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 20

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Phase I : Façade

Structural

Mechanical

Lighting/ Electrical

ConstructionPhase II:

Cogeneration

Structural

Mechanical

Lighting/ Electrical

Construction

Phase III: Lateral System

Structural

Mechanical

Lighting/ Electrical

Construction

Phase IV: Distribution

Systems/ Coordination

Structural

Mechanical

Lighting/ Electrical

Construction

Team Workflow

Page 21: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 21

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Phase IV: Distribution and

Coordination

Phase III:

Lateral System

Phase II: Cogeneration

Phase I: FaçadeVision of

Transparency

Energy Data

Final Distribution System Design

Façade Mounting Data

Final Structural Layout

Team Workflow

Page 22: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 22

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Phase IV: Distribution and

Coordination

Phase III:

Lateral System

Phase II: Cogeneration

Phase I: FaçadeVision of

Transparency

Energy Data

Final Distribution System Design

Façade Mounting Data

Final Structural Layout

Similar to fast-tracked design build with bid packages

Team Workflow

Page 23: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 23

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Phase IV: Distribution and

Coordination

Phase III:

Lateral System

Phase II: Cogeneration

Phase I: FaçadeVision of

Transparency

Energy Data

Final Distribution System Design

Façade Mounting Data

Final Structural Layout

Similar to fast-tracked design build with bid packages

Allows for leadership roles to evolve naturally

Team Workflow

Page 24: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 24

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Phase IV: Distribution and

Coordination

Phase III:

Lateral System

Phase II: Cogeneration

Phase I: FaçadeVision of

Transparency

Energy Data

Final Distribution System Design

Façade Mounting Data

Final Structural Layout

Team Workflow

Page 25: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 25

Phase I:

Facade

Page 26: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 26

Key Aspects:

Open office – 45 fc ave. + Task Lighting

Private office – 35 fc ave. + Task Lighting

Circulation areas – 30 fc ave.

Brighter Interior Wall

Reducing contrast of a bright perimeter during the day

10’ spacing leaving room for:

Fire protection

Mechanical equipment

Lighting control equipment

View out provided by façade redesign

Typical Floor

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 27: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 27

Key Aspects:

Open office lighting

Brighter interior wall

10’ spacing

Private office lighting

View out

Typical Floor

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 28: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 28

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Daylight Analysis

Page 29: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 29

Existing - RodsRedesign - Blades

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 30: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 30

Existing - RodsRedesign - Blades

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 31: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 31

Noon

Looking For:

Direct sunlight penetration

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 32: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 32

Existing - RodsRedesign - Blades

Solar Noon

Page 33: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 33

Existing - RodsRedesign - Blades

February 22nd

Noon

Page 34: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 34

Existing - RodsRedesign - Blades

March 22nd

Noon

Page 35: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 35

Existing - RodsRedesign - Blades

April 22nd

Noon

Page 36: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 36

Existing - RodsRedesign - Blades

May 22nd

Noon

Page 37: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 37

Existing - RodsRedesign - Blades

June 22nd

Noon

Page 38: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 38

Existing - RodsRedesign - Blades

July 22nd

Noon

Page 39: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 39

Existing - RodsRedesign - Blades

August 22nd

Noon

Page 40: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 40

Existing - RodsRedesign - Blades

September 22nd

Noon

Page 41: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 41

Existing - RodsRedesign - Blades

October 22nd

Noon

Page 42: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 42

Existing - RodsRedesign - Blades

November 22nd

Noon

Page 43: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 43

Existing - RodsRedesign - Blades

December 22nd

Noon

Page 44: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 44

Summer Solstice

Both performed similar and will not be presented

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 45: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 45

Winter Solstice

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 46: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 46

Existing - RodsRedesign - Blades

Winter Solstice

8am

Page 47: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 47

Existing - RodsRedesign - Blades

Winter Solstice

9am

Page 48: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 48

Existing - RodsRedesign - Blades

Winter Solstice

10am

Page 49: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 49

Existing - RodsRedesign - Blades

Winter Solstice

11am

Page 50: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 50

Existing - RodsRedesign - Blades

Winter Solstice

12pm

Page 51: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 51

Existing - RodsRedesign - Blades

Winter Solstice

1pm

Page 52: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 52

Existing - RodsRedesign - Blades

Winter Solstice

2pm

Page 53: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 53

Existing - RodsRedesign - Blades

Winter Solstice

3pm

Page 54: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 54

Existing - RodsRedesign - Blades

Winter Solstice

4pm

Page 55: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 55

Equinox

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 56: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 56

Existing - RodsRedesign - Blades

Equinox

7am

Page 57: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 57

Existing - RodsRedesign - Blades

Equinox

8am

Page 58: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 58

Existing - RodsRedesign - Blades

Equinox

9am

Page 59: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 59

Existing - RodsRedesign - Blades

Equinox

10am

Page 60: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 60

Existing - RodsRedesign - Blades

Equinox

11am

Page 61: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 61

Existing - RodsRedesign - Blades

Equinox

12pm

Page 62: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 62

Existing - RodsRedesign - Blades

Equinox

1pm

Page 63: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 63

Existing - RodsRedesign - Blades

Equinox

3pm

Page 64: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 64

Existing - RodsRedesign - Blades

Equinox

4pm

Page 65: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 65

Existing - RodsRedesign - Blades

Equinox

5pm

Page 66: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 66

Existing - RodsRedesign - Blades

Equinox

6pm

Page 67: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 67

Existing - RodsRedesign - Blades

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 68: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 68

Existing - RodsRedesign - Blades

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 69: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 69

Existing - RodsRedesign - Blades

Sun View

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 70: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 70

Existing - RodsRedesign - Blades

Pedestrian View

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 71: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 71

.1fc

.5fc

1fc

2.5fc

5fc

Page 72: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 72

Glazing Properties

Redesigned Glazing

Manufacturer: Oldcastle Glass

Double-paned insulated glazing unit

Visual light transmittance: 74%

Overall U-value: 0.280 [Btu/ft2- F]

Shading coefficient: 0.73

Existing Glazing

Manufacturer: Saint-Gobain Glass

Double-paned insulated glazing unit

Visual light transmittance: 96%

Overall U-value: 0.625 [Btu/ft2- F]

Shading coefficient: 0.46

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 73: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 73

Spandrel Properties

Existing Spandrel

Cavity wall system

Overall U-value: 0.087 [Btu/ft2- F]

Condensation: 37 [grains H2O/ft2-day]

1. 3/16” aluminum panel

2. 1/2” air space

3. Vapor barrier

4. 2-1/2” rigid insulation

1

4

2

3

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 74: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 74

1

2

3

1

4

2

3

Spandrel Properties

Existing Spandrel

Cavity wall system

Overall U-value: 0.087 [Btu/ft2- F]

Condensation: 37 [grains H2O/ft2-day]

1. 3/16” aluminum panel

2. 1/2” air space

3. Vapor barrier

4. 2-1/2” rigid insulation

Redesigned Spandrel

Barrier wall system

Overall U-value: 0.067 [Btu/ft2- F]

Condensation: <2 [grains H2O/ft2-day]

1. 22 gauge aluminum panel

2. 3-1/2” rigid insulation

3. Vapor barrier

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 75: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 75

Wall Sections

Existing Wall

UFAD system requires large plenum

Lighting cove for improved daylighting

Floor-to-ceiling height: 9’-7”

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 76: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 76

Wall Sections

Redesigned Wall

Lower raised floor

• Elimination of UFAD

Floor-to-ceiling height: 9’-11”

Interstitial height decrease

Existing Wall

UFAD system requires large plenum

Lighting cove for improved daylighting

Floor-to-ceiling height: 9’-7”

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 77: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 77

70%

30%

Existing Facade: Cooling Load

Envelope Loads Internal Loads

48%52%

Redesigned Facade: Cooling Load

Envelope Loads Internal Loads

Existing Redesign

Cooling [Btu/hr-ft2] 39.7 25.7

Heating [Btu/hr-ft2] 51.9 30.6

Façade Energy Analysis

Façade redesign reduced envelope loads due to:

• More effective shading scheme

• Improved U-value of glazing and spandrel

• Enhanced glazing transmittance and shading coefficient

Peak load reduction for typical floor:

• Cooling: 35%

• Heating: 21%

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 78: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 78

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Jan Feb Mar April May June July Aug Sept Oct Nov Dec

Co

ns

um

pti

on

[k

Wh

]

Electricity Consumption for Typical Floor

Existing Facade Redesigned Facade

0

200

400

600

800

1,000

1,200

1,400

1,600

1,800

2,000

Jan Feb Mar April May June July Aug Sept Oct Nov Dec

Co

ns

um

pti

on

[T

he

rms

]

Gas Consumption for Typical Floor

Existing Facade Redesigned Facade

Monthly Energy Requirements

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 79: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Façade support system

4.14.2010 79

Existing shading system estimated at 25 psf

Includes ice on rods

New system weighs ~ 18 psf

C-shaped members allow unitized connection

Bolted in 2 places per panel

Same support used for new system

Thermal expansion calculated

120ºF temperature differential

¼” expansion per panel

Mullions and structural glazing redesigned

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 80: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 80

Double width façade panel was investigated for schedule savings

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 81: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 81

Double width façade panel was investigated for schedule savings

Not possible due to material hoist limitations

Additional information available in report

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 82: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 82

Façade

Area

Average

Façade Unit

Cost

Rods Rod Unit Cost Total Cost

(SF) ($/ SF) (ea.) ($/ rod) ($)

Typical Tower Floor 10,678 $144 14510 $20 $1,606,290.00

Entire Building 555,236 $144 754,510 $20 $83,527,200.00

Cost of Existing Façade System

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 83: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 83

Façade

Area

Average

Façade Unit

Cost

Rods Rod Unit Cost Total Cost

(SF) ($/ SF) (ea.) ($/ rod) ($)

Typical Tower Floor 10,678 $144 14510 $20 $1,606,290.00

Entire Building 555,236 $144 754,510 $20 $83,527,200.00

Cost of Existing Façade System

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 84: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 84

Façade

Area

Average

Façade Unit

Cost

Rods Rod Unit Cost Total Cost

(SF) ($/ SF) (ea.) ($/ rod) ($)

Typical Tower Floor 10,678 $144 14510 $20 $1,606,290.00

Entire Building 555,236 $144 754,510 $20 $83,527,200.00

Material Labor Total Cost

($) ($) ($)

Typical Tower Floor $810,414 $1,343,285 $2,153,700

Entire Building $45,383,218 $75,223,990 $120,607,208

Cost of Existing Façade System Cost of Redesigned Façade System

Building Overview

Team Workflow

Phase I : Façade

Typical Floor

Daylighting Analysis

Energy Analysis

Assembly and Cost

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 85: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 85

Phase II :

Cogeneration

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 86: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 86

9.1

15.2

24.9

0.0

5.0

10.0

15.0

20.0

25.0

30.0

US Average New York State New York City

Price of Electricity [¢/kWh]

0.6250.885

1.392

0.000

0.400

0.800

1.200

1.600

US Average New York State New York City

Price of Natural Gas [$/CCF]

Price of Energy

Electric and natural gas prices obtained from the EIA for 2007

Steam prices are difficult to compare because they are set by each utility

• Price of steam for large commercial customer in New York City:

• 18.36 [$/1,000 lbs] - ConEd

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 87: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 87

Plant Equipment Sizing Methodology

0

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000

4,500

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Co

oli

ng

Lo

ad

[to

ns

]

Hour

Seasonal Building Cooling Load

Winter Fall/Spring Summer

CV Chiller

(1050 tons)

VFD Chiller

(1300 tons)

VFD Chiller

(2170 tons)

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 88: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 88

0

5,000,000

10,000,000

15,000,000

20,000,000

25,000,000

30,000,000

35,000,000

40,000,000

45,000,000

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

He

ati

ng

Lo

ad

[B

tu/h

]

Hour

Seasonal Building Heating Load

Winter Summer Fall/Spring

Region 1:

Consistent Base

Load

Region 2:

Highly variable

Region 3:

Infrequent, high

peaking

Plant Equipment Sizing Methodology

0

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000

4,500

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Co

oli

ng

Lo

ad

[to

ns

]

Hour

Seasonal Building Cooling Load

Winter Fall/Spring Summer

CV Chiller

(1050 tons)

VFD Chiller

(1300 tons)

VFD Chiller

(2170 tons)

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 89: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 89

Alternative 1 Alternative 2 Alternative 3 Alternative 4 Alternative 5

Chiller Plant

Low range CV ElectricAbsorption

(1-stage)

Absorption

(2-stage)

Absorption

(2-stage)

Absorption

(2-stage)

Mid range VFD ElectricAbsorption

(1-stage)

Absorption

(2-stage)

Steam Comp.

(2-stage)Electric

High range VFD Electric Electric ElectricSteam Comp.

(2-stage)Electric

Prime Movers

Low rangeIC Engine

(VFD)

Gas Turbine

(CV)

Gas Turbine

(CV)

Gas Turbine

(CV)

IC Engine

(VFD)

Mid rangeGas Turbine

(CV)Steam

Generator

(VFD)

IC Engine

(VFD)

Gas Turbine

(CV)

Gas Turbine

(CV)

High rangeIC Engine

(VFD)

Steam Gen.

(VFD)

Steam Gen.

(VFD)

IC Engine

(VFD)

Annual Operating Costs [$/yr] 10,133,170 8,155,927 7,459,702 7,704,658 7,794,157

Annual Primary Energy

[MMBtu/yr]444,224 546,834 446,416 516,813 424,050

Preliminary Plant Study

Energy Modeling Assumptions

TRACE model from Phase I was adapted for the entire building

Used “average monthly hourly” TMY data for analysis

Electrical loads

• Lighting: 1.1 [W/ft2]

• Plug loads: 0.5 [W/ft2]

• Misc. loads: 1.0 [W/ft2]

• Data center: 1,200,000 [W]

• Load profile was applied to all electrical loads (except data center)

Modeled part-load plant operating characteristics by weighting COP and heat rate

for each hourly time-step

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 90: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Alternative 1 Alternative 2 Alternative 3 Alternative 4 Alternative 5

Chiller Plant

Low range CV ElectricAbsorption

(1-stage)

Absorption

(2-stage)

Absorption

(2-stage)

Absorption

(2-stage)

Mid range VFD ElectricAbsorption

(1-stage)

Absorption

(2-stage)

Steam Comp.

(2-stage)Electric

High range VFD Electric Electric ElectricSteam Comp.

(2-stage)Electric

Prime Movers

Low rangeIC Engine

(VFD)

Gas Turbine

(CV)

Gas Turbine

(CV)

Gas Turbine

(CV)

IC Engine

(VFD)

Mid rangeGas Turbine

(CV)Steam

Generator

(VFD)

IC Engine

(VFD)

Gas Turbine

(CV)

Gas Turbine

(CV)

High rangeIC Engine

(VFD)

Steam Gen.

(VFD)

Steam Gen.

(VFD)

IC Engine

(VFD)

Annual Operating Costs [$/yr] 10,133,170 8,155,927 7,459,702 7,704,658 7,794,157

Annual Primary Energy

[MMBtu/yr]444,224 546,834 446,416 516,813 424,050

4.14.2010 90

Preliminary Plant Study

Energy Modeling Assumptions

TRACE model from Phase I was adapted for the entire building

Used “average monthly hourly” TMY data for analysis

Electrical loads

• Lighting: 1.1 [W/ft2]

• Plug loads: 0.5 [W/ft2]

• Misc. loads: 1.0 [W/ft2]

• Data center: 1,200,000 [W]

• Load profile was applied to all electrical loads (except data center)

Modeled part-load plant operating characteristics by weighting COP and heat rate

for each hourly time-step

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 91: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 91

Final Equipment Selection

Chiller Plant

(1) – 1,058 [ton] double-stage absorption chiller

• Trane ABTF-1050

• COP: 1.21

• Steam fired

(1) – 1,300 [ton] two-stage, single compressor electric chiller

• Trane CVHF-1300

• COP: ~ 6.1

(1) – 2,170 [ton] dual compressor electrical chillers

• Trane CDHF-2170

• COP: ~ 6.1

• (1) chiller for stand-by

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 92: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 92

Final Equipment Selection

Chiller Plant

(1) – 1,058 [ton] double-stage absorption chiller

• Trane ABTF-1050

• COP: 1.21

• Steam fired

(1) – 1,300 [ton] two-stage, single compressor electric chiller

• Trane CVHF-1300

• COP: ~ 6.1

(1) – 2,170 [ton] dual compressor electrical chillers

• Trane CDHF-2170

• COP: ~ 6.1

• (1) chiller for stand-by

CHP Plant

(1) – 1,185 [kW] gas turbine

• Solar Saturn 20

• Heat rate: 13,906 [Btu/kWh]

• Recoverable heat rate: 8,975 [Btu/kWh]

• Electrical efficiency: 25%

(2) – 1,040 [kW] internal combustion engines

• Caterpillar G3516

• Heat rate: 10,593 [Btu/kWh]

• Recoverable heat rate: 5,234 [Btu/kWh]

• Electrical efficiency: 32%

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 93: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 93

Flow Diagrams

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 94: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 94

Flow Diagrams

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 95: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 95

Mechanical Systems Performance

531,723 551,261

431,602

0

100,000

200,000

300,000

400,000

500,000

600,000

Existing CHP Redesigned SHP Redesigned CHP

En

erg

y [

MM

Btu

]

Annual Primary Energy Used

Primary energy use reduction from existing building: 19%

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 96: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 96

531,723 551,261

431,602

0

100,000

200,000

300,000

400,000

500,000

600,000

Existing CHP Redesigned SHP Redesigned CHP

En

erg

y [

MM

Btu

]

Annual Primary Energy Used

0.447

0.458

0.480

0.400

0.410

0.420

0.430

0.440

0.450

0.460

0.470

0.480

0.490

0.500

Existing CHP Redesigned SHP Redesigned CHP

Annual Primary Fuel Utilization Efficiency

CHP Existing SHP Redesign CHP Redesign

[lbs CO2/yr] 67,562,895 84,787,465 63,443,589

[lbs NOx/yr] 497,038 135,807 292,978

[lbs SOx/yr] 285,510 333,528 210,681

Mechanical Systems Performance

Primary energy use reduction from existing building: 19%

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 97: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 97

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Spring Energy Cost: (Mar-May)

Natural Gas PurchasedElectricity Purchased Steam Purchased

Normal Operating Costs

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 98: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 98

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Spring Energy Cost: (Mar-May)

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Summer Energy Cost: (Jun-Aug)

Natural Gas PurchasedElectricity Purchased Steam Purchased

Normal Operating Costs

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 99: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 99

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Spring Energy Cost: (Mar-May)

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Summer Energy Cost: (Jun-Aug)

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Fall Energy Cost: (Sep-Nov)

Natural Gas PurchasedElectricity Purchased Steam Purchased

Normal Operating Costs

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 100: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 100

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Winter Energy Cost: (Dec-Feb)

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Spring Energy Cost: (Mar-May)

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Summer Energy Cost: (Jun-Aug)

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Fall Energy Cost: (Sep-Nov)

Natural Gas PurchasedElectricity Purchased Steam Purchased

Normal Operating Costs

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 101: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 101

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Winter Energy Cost: (Dec-Feb)

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Spring Energy Cost: (Mar-May)

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Summer Energy Cost: (Jun-Aug)

$0

$500,000

$1,000,000

$1,500,000

$2,000,000

$2,500,000

$3,000,000

$3,500,000

CHP Baseline SHP Redesign

CHP Redesign

Fall Energy Cost: (Sep-Nov)

Natural Gas PurchasedElectricity Purchased Steam Purchased

Normal Operating Costs

CHP Baseline: $ 10,983,700 / year

SHP Redesign: $ 12,081,500 / year

CHP Redesign: $ 8,773,200 / year

Energy cost reduction from

existing building: 20%

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 102: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 102

0

1,000

2,000

3,000

4,000

5,000

6,000

7,000

8,000

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Ele

ctr

ic D

em

an

d [

kW

]

Hour

Peak Load Shedding Strategy

Electric Demand

Electric Load Control

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 103: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 103

0

1,000

2,000

3,000

4,000

5,000

6,000

7,000

8,000

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Ele

ctr

ic D

em

an

d [

kW

]

Hour

Peak Load Shedding Strategy

Electric Demand Purchased Electricity

Purchase Cap set

at 4,129 [kW]

Electric Load Control

Electrical load shedding strategy

Building’s peak electrical demand: 7,394 [kW]

Installed generation capacity: 3,265 [kW]

Recommended strategy: Peak purchase cap

• Guarantees no more that 4,129 [kW] be purchased from the utility

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 104: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 104

0

1,000

2,000

3,000

4,000

5,000

6,000

7,000

8,000

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Ele

ctr

ic D

em

an

d [

kW

]

Hour

Peak Load Shedding Strategy

Electric Demand Purchased Electricity

When demand is below purchase

cap, PMs follow heating load.

When demand is above purchase

cap, PMs follow electrical load to

maintain purchase cap.

Purchase Cap set

at 4,129 [kW]

Electric Load Control

Electrical load shedding strategy

Building’s peak electrical demand: 7,394 [kW]

Installed generation capacity: 3,265 [kW]

Recommended strategy: Peak purchase cap

• Guarantees no more that 4,129 [kW] be purchased from the utility

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 105: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 105

0

1,000

2,000

3,000

4,000

5,000

6,000

7,000

8,000

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Ele

ctr

ic D

em

an

d [

kW

]

Hour

Peak Load Shedding Strategy

Electric Demand Purchased Electricity

When demand is below purchase

cap, PMs follow heating load.

When demand is above purchase

cap, PMs follow electrical load to

maintain purchase cap.

Purchase Cap set

at 4,129 [kW]

Electric Load Control

Electrical load shedding strategy

Building’s peak electrical demand: 7,394 [kW]

Installed generation capacity: 3,265 [kW]

Recommended strategy: Peak purchase cap

• Guarantees no more that 4,129 [kW] be purchased from the utility

“Critical Peak Rebate Program”

NYT Building has lean burning generators which may act as localized

emergency back-up for the utility

ConEd agrees to pay 1.50 [$/kW] in the case when the CHP plant has extra

generating capacity and load relief is needed

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 106: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Podium framing

4.14.2010 106

Larger area containing mechanical equipment

Located as far away from the tower as possible to prevent

vibration effects

RAM Structural System used to analyze and redesign

framing

Existing W21x44 beam members not sufficient

Increased to W24x62

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 107: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 107

ItemShipping

Weight (lb)Elevation (ft)

Horizontal Distance

from Crane (ft)

Absorption Chiller 59,800 -16 40

Electric Chiller (Single Compressor) 37,701 -16 40

Electric Chiller (Dual Compressor) 78,890 -16 40

Internal Combustion Engine 20,560 80 180

Gas Turbine Engine 23,215 80 180

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Crane Selection

Page 108: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 108

ItemShipping

Weight (lb)Elevation (ft)

Horizontal Distance

from Crane (ft)

Absorption Chiller 59,800 -16 40

Electric Chiller (Single Compressor) 37,701 -16 40

Electric Chiller (Dual Compressor) 78,890 -16 40

Internal Combustion Engine 20,560 80 180

Gas Turbine Engine 23,215 80 180

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Crane Selection

440 ton Manitowoc 16000 crawler crane selected for controlling lift (by weight)

No increase to general conditions cost

Full data available in report

Page 109: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 109

Equipment Cost

($)

Labor Cost

($)

Annual Operating Cost

($)

CHP Baseline $3,673,500.00 $114,750.00 $10,983,700.00

CHP Redesign $6,708,800.00 $255,000.00 $8,773,200.00

Difference ($3,035,300.00) ($140,250.00) $2,210,500.00

Annual Savings $2,210,500.00

Payback of Redesign 3.15 Years

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

CHP Cost Comparison

Page 110: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 110

Equipment Cost

($)

Labor Cost

($)

Annual Operating Cost

($)

CHP Baseline $3,673,500.00 $114,750.00 $10,983,700.00

CHP Redesign $6,708,800.00 $255,000.00 $8,773,200.00

Difference ($3,035,300.00) ($140,250.00) $2,210,500.00

Annual Savings $2,210,500.00

Payback of Redesign 3.15 Years

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

CHP Cost Comparison

Page 111: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 111

Interest

Rate

Initial Annual

PMT

FV of Loan at End

Repayment Period

Annual Savings

Applied to

Payments

Potential PV w/

savings applied to

payment

Potential NP w/ savings

applied to payment

0.015 ($50,242,255.52) ($1,256,056,387.88) ($2,210,500.00) $1,086,800,700.55 23.74

0.02 ($53,320,476.39) ($1,333,011,909.81) ($2,210,500.00) $1,084,156,600.53 23.73

0.025 ($56,501,233.81) ($1,412,530,845.22) ($2,210,500.00) $1,081,727,084.08 23.72

0.03 ($59,782,413.75) ($1,494,560,343.79) ($2,210,500.00) $1,079,491,762.97 23.71

0.035 ($63,161,670.86) ($1,579,041,771.57) ($2,210,500.00) $1,077,432,388.01 23.69

0.04 ($66,636,453.26) ($1,665,911,331.52) ($2,210,500.00) $1,075,532,607.72 23.67

0.045 ($70,204,028.19) ($1,755,100,704.71) ($2,210,500.00) $1,073,777,755.91 23.65

0.05 ($73,861,508.05) ($1,846,537,701.21) ($2,210,500.00) $1,072,154,664.46 23.63

Given: $1.041 Billion initial loan (including redesign)

Assumed 25 year initial payback period

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Loan Repayment Analysis

Page 112: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 112

Interes

t RateInitial Annual PMT

FV of Loan at End

Repayment Period

Annual Savings

Applied to

Payments

Potential PV w/

savings applied to

payment

Potential NP w/

savings applied

to payment

0.015 ($50,242,255.52) ($1,256,056,387.88) ($2,210,500.00) $1,086,800,700.55 23.74

0.02 ($53,320,476.39) ($1,333,011,909.81) ($2,210,500.00) $1,084,156,600.53 23.73

0.025 ($56,501,233.81) ($1,412,530,845.22) ($2,210,500.00) $1,081,727,084.08 23.72

0.03 ($59,782,413.75) ($1,494,560,343.79) ($2,210,500.00) $1,079,491,762.97 23.71

0.035 ($63,161,670.86) ($1,579,041,771.57) ($2,210,500.00) $1,077,432,388.01 23.69

0.04 ($66,636,453.26) ($1,665,911,331.52) ($2,210,500.00) $1,075,532,607.72 23.67

0.045 ($70,204,028.19) ($1,755,100,704.71) ($2,210,500.00) $1,073,777,755.91 23.65

0.05 ($73,861,508.05) ($1,846,537,701.21) ($2,210,500.00) $1,072,154,664.46 23.63

Given: $1.041 Billion initial loan (including redesign)

Assumed 25 year initial payback period

With monthly utility savings applied to loan payments:

Owner can borrow an additional $38 Million

Owner can pay back loan 1.3 years faster

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Plant Studies

System Operation

Interdisciplinary Coordination

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Loan Repayment Analysis

Page 113: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 113

Phase III :

Lateral Systems

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 114: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Structural Overview: Lateral system

4.14.2010 114

Steel eccentric and concentric chevron

braced frames

Exterior X-braces: pre-stressed rods

Outrigger level at 28th and 51st floors

7

6

5

4

3

2

1

8

A B C D E

7

6

5

4

3

2

1

8

A B C D E

below 28th floor above 28th floor

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 115: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Goals for Redesign

4.14.2010 115

Create a penthouse level by removing the outrigger at the 51st level

Bring in revenue with new space

Eliminate exterior X-braces for efficiency

Take advantage of extra structural depth with moment frames

Meet original design criteria

Drift: H/450

Periods of vibration: 6.25 seconds – 6.75 seconds

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 116: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

7

6

5

4

3

2

1

8

A B C D E

Lateral system

4.14.2010 116

Option 1

Moment frames in both the N-S and E-W directions provide

stiffness in lieu of 51st outrigger

Concentric steel braces replace eccentric braces

System is heavier due to amount of moment frames/added steel

N-S moment frames skewed along grid C

Not considered further

7

6

5

4

3

2

1

8

A B C D E

below 28th floor above 28th floor

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 117: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Lateral system

4.14.2010 117

Option 2

Moment frames only in the E-W direction

Bracing members lighter due to contributing stiffness

E-W is much stiffer than N-S

Look into adding stiffness in N-S direction

Can eliminate some E-W members

Not considered further

7

6

5

4

3

2

1

8

A B C D E

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 118: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Lateral system

4.14.2010 118

Option 3

Moment frames only in the E-W direction

Symmetry in both directions

E-W line of bracing removed

N-S line of bracing added

Members in the N-S direction able to be lighter

System chosen for further analysis

7

6

5

4

3

2

1

8

A B C D E

7

6

5

4

3

2

1

8

A B C D E

below 28th floor above 28th floor

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 119: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Lateral system

4.14.2010 119

Used wind tunnel base shear

Approximately 2/3 that determined via ASCE 7-05

Cases 1-4 were considered

Symmetrical system eliminates inherent torsion

Case 1 controlled the design

Bracing sizes based on strength calculated in Excel spreadsheet

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 120: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Lateral system

4.14.2010 120

Modeled in 3D in ETABS using rigid and semi-rigid diaphragms

Dynamic analysis for periods of vibration

User-defined members - built-up and box columns

P-delta effects

Shear and axial deformations

Panel zones explicitly modeled

Sizes grouped

E-W N-S

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 121: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Lateral system

4.14.2010 121

Concentric braces used throughout due to newly ducted mechanical

system

Bracing sizes increased to meet drift and period requirements

Original system: W14x68 to W14x455

New system: W14x53 to W14x176 (with additional N-S bracing line)

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 122: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Lateral system

4.14.2010 122

3.5% structural weight savings

21.9 psf existing

21.1 psf new

Periods of vibration

6.7 seconds in E-W

6.3 seconds in N-S

Drift limit of 19.9” (H/450)

E-W drift: 17.9”

N-S drift: 13.4”

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 123: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Lateral system

4.14.2010 123

Thermal movement study

Outriggers controlled differential movement

Causes floor racking and partition separation

Δ28 = 6.45x10-6 in/in- F * (12in * 357.5’) * 120 F = 3.32 inches

Allowable floor deflection L/180= 2.66”

Thermal movement of exterior exposed columns is an issue

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 124: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Lateral system

4.14.2010 124

Two options found

Belt truss or outrigger

Heat/cool columns

Controlling the temperature would likely increase costs

“Thermal” truss relocated to roof

Lateral system could be revisited utilizing truss for additional stiffness

Bracing members could be optimized further

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 125: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 125

Mechanical Equipment Relocation

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

14,392

6,000

1,532

Space Requirements for 51st

Floor [ft2]

Net Usable

Core

Mechanical

420 1,456

2,408

1,532

12,224

Space Requirements for Roof [ft2]

Water Tanks

Cooling Towers

Maintenance Platform

New Equipment

Remaining Area

Page 126: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 126

Mechanical Equipment Relocation

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

14,392

6,000

1,532

Space Requirements for 51st

Floor [ft2]

Net Usable

Core

Mechanical

420 1,456

2,408

1,532

12,224

Space Requirements for Roof [ft2]

Water Tanks

Cooling Towers

Maintenance Platform

New Equipment

Remaining Area

Page 127: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 127

Mechanical Equipment Relocation

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

14,392

6,000

1,532

Space Requirements for 51st

Floor [ft2]

Net Usable

Core

Mechanical

420 1,456

2,408

1,532

12,224

Space Requirements for Roof [ft2]

Water Tanks

Cooling Towers

Maintenance Platform

New Equipment

Remaining Area

Page 128: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 128

Mechanical Equipment Relocation

14,392

6,000

1,532

Space Requirements for 51st

Floor [ft2]

Net Usable

Core

Mechanical

420 1,456

2,408

1,532

12,224

Space Requirements for Roof [ft2]

Water Tanks

Cooling Towers

Maintenance Platform

New Equipment

Remaining Area

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 129: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK

Progressive collapse

4.14.2010 129

Linear-static method: GSA

Considers redistribution within frame of LC 2(1.0D + 0.25L)

Modeled and analyzed as a 2D frame in ETABS

Calculated DCR based on plastic moments

All members failed: potential for progressive collapse

Nonlinear-static method: GSA

Virtual work used for analysis: does not consider redistribution

All members failed: potential for progressive collapse

Should be modeled as a 3D frame in ETABS as DoD requires

Considers redistribution of loads to other frames and bays

PROGRESSIVE COLLAPSE LINEAR STATIC ANALYSISbeam shear (k) beam moment ('k) allowable shear (k) allowable moment (k) required section

2, A&B 2, B&C 2, A&B 2, B&C 2, A&B check 2, B&C check 2, A&B check 2, B&C check 2, A&B section 2, B&C section

level W18x50 W16x36 W18x50 W16x36 W18x50 DCR<2 W16x36 DCR<2 W18x50 DCR<3 W16x36 DCR<3 ФMp ФMp

2 190.90 198.40 3796.4 3214.1 192 OK 140 OK 379 NG!! 240 NG!! 1270 W30x108 1075 W30x99

3 189.82 199.01 3772.1 3222.4 192 OK 140 OK 379 NG!! 240 NG!! 1262 W30x108 1078 W30x99

4 188.73 199.65 3752.1 3234.2 192 OK 140 OK 379 NG!! 240 NG!! 1255 W30x108 1082 W30x99

5 187.62 199.99 3730.6 3239.9 192 OK 140 OK 379 NG!! 240 NG!! 1248 W30x108 1084 W30x99

6 186.67 200.16 3711.6 3242.6 192 OK 140 OK 379 NG!! 240 NG!! 1241 W30x108 1084 W30x99

7 185.85 200.23 3695.2 3243.7 192 OK 140 OK 379 NG!! 240 NG!! 1236 W30x108 1085 W30x99

8 185.11 200.19 3680.1 3237.4 192 OK 140 OK 379 NG!! 240 NG!! 1231 W30x108 1083 W30x99

9 184.43 200.02 3665.1 3240.3 192 OK 140 OK 379 NG!! 240 NG!! 1226 W30x108 1084 W30x99

10 183.29 199.82 3638.7 3237.0 192 OK 140 OK 379 NG!! 240 NG!! 1217 W30x108 1083 W30x99

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Preliminary Study

Redesign

Mechanical Relocation

Progressive Collapse

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Page 130: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 130

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Phase IV :

Distribution Systems

and Coordination

Page 131: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 131

Proposed Mechanical Distribution

Removal of UFAD

Issues with long-term indoor air quality

Thermal comfort problems due to localized under/over pressurization

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 132: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 132

30 x 132 beam clashing with a 24” x 80” duct (recreated in Navisworks)

Proposed Mechanical Distribution

Removal of UFAD

Issues with long-term indoor air quality

Thermal comfort problems due to localized under/over pressurization

Elimination of VAV

Proposal included a comparison between an all-air variable air volume system

(VAV) and a dedicated outdoor air system with active chilled beams

New structural space requirements eliminated the feasibility of a VAV system

Selected a dedicated outdoor air system (DOAS) with active chilled beams (ACB)

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 133: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 133

System Selection

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 134: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 134

Supply Air

Room Air

Active Chilled Beam

System Selection

Design considerations

Easy to implement demand controlled ventilation

Ventilation and heating/cooling loads are decoupled

DOAS/ACB recommendations (Mumma et al):

• Space dewpoint: 45 F

• Supply air temperature: 55 F

• Discharge air temperature: 64-66 F

• 5:1 mixing ratio at terminal unit

• Chilled water supply temperature: 57-61 F

TROX 2-pipe active chilled beams as standard

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 135: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 135

System Operation

General operation

Outdoor air unit:

• Removes all latent loads

• Supply fan – 55,000 [CFM]

• Enthalpy wheel operates at around 64% effectiveness (unbalanced flow)

• Steam humidifier to maintain space minimum 0.006 [lb H2O/lb DA]

Floor-by-floor

• Supply fan – 2,500 [CFM] (ASHRAE Std. 62.1 + 30%)

• Zone T-stat controls tempered chilled water in ACBs and perimeter finned tube

• Occupancy sensors in single-zone rooms allow for VAV box reset

• CO2 sensor in return duct for each quadrant

• Relative humidity sensor in space for each quadrant

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 136: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 136

Ceiling Layout Coordination

Lighting and chilled beams

Selected linear devices

Oriented in the North-South direction

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 137: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 137

Material Qty. Unit Cost Cost Per FloorCost for NYT

Spaces

Ductwork and Connections 11,400 lb $0.76 $8,664.00 $242,592.00

Chilled Beams 161 EA $800.00 $128,800.00 $3,606,400.00

VAV Box and Connections 44 EA $18.00 $792.00 $22,176.00

Outdoor Air Units 2 EA $26,100.00 - $52,200.00

Labor Qty. Unit Unit Cost Cost Per FloorCost for NYT

Spaces

Ductwork and Connections 11,400 lb $8.86 $101,004.00 $2,828,112.00

Chilled Beams 161 EA $217.00 $34,937.00 $978,236.00

VAV Box and Connections 44 EA $57.33 $2,522.00 $70,630.00

Outdoor Air Units 2 EA 8778 - $17,556.00

Total: ($276,719.00) ($7,800,346.00)

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Mechanical Systems Cost

Page 138: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 138

Conductor to Bus Duct Comparison

500mcm - Copper Conductors - Existing Conditions

From DP to Floor __

Length + 5'per termination (6)

3-1/2" - Conduit

Price Length Number Total Price Length Total

4 $19.99 175 205 4 $16,421.79 $28.06 175 $4,921.02

7 $19.99 217 247 4 $19,750.12 $28.06 217 $6,089.02

10 $19.99 259 289 4 $23,078.46 $28.06 259 $7,257.02

13 $19.99 300 330 4 $26,406.79 $28.06 300 $8,425.02

16 $19.99 342 372 4 $29,735.13 $28.06 342 $9,593.01

19 $19.99 384 414 4 $33,063.46 $28.06 384 $10,761.01

22 $19.99 425 455 4 $36,391.80 $28.06 425 $11,929.01

25 $19.99 467 497 4 $39,720.13 $28.06 467 $13,097.01

28 $19.99 508 538 4 $43,048.47 $28.06 508 $14,265.00

TOTALS: $267,616.13 $86,337.11

Price per side $353,953.24

Price Both sides $707,906.48

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 139: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 139

Conductor to Bus Duct Comparison

750mcm - Aluminum Conductors

From DP to Floor __

Length + 5'per termination(6)

3-1/2" - Conduit

Price Length Number Total Price Length Total

4 $10.18 175 205 4 $8,362.87 $31.61 175 $5,543.60

7 $10.18 217 247 4 $10,057.84 $31.61 217 $6,859.37

10 $10.18 259 289 4 $11,752.81 $31.61 259 $8,175.14

13 $10.18 300 330 4 $13,447.78 $31.61 300 $9,490.90

16 $10.18 342 372 4 $15,142.75 $31.61 342 $10,806.67

19 $10.18 384 414 4 $16,837.72 $31.61 384 $12,122.44

22 $10.18 425 455 4 $18,532.69 $31.61 425 $13,438.20

25 $10.18 467 497 4 $20,227.66 $31.61 467 $14,753.97

28 $10.18 508 538 4 $21,922.63 $31.61 508 $16,069.73

TOTALS: $136,284.75 $97,260.02

Price per side $233,544.77

Price Both sides $467,089.54

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 140: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 140

Conductor to Bus Duct Comparison

2500A - Copper Bus Duct

From DP to Floor __ Price Units Length Number Total28 Bus $980.79 LF 508 1 $498,609.12

Elbows / Up / Downs $4,054.37 EA - 5 $20,271.85Taps $6,279.75 EA - 28 $175,833.00

Price per side $694,713.97Price Both sides $1,389,427.93

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 141: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 141

Conductor to Bus Duct Comparison

2500A - Aluminum Bus Duct

From DP to Floor__ Price Units Length Number Total28 Bus $827.70 LF 508 1 $420,781.99

Elbows / Up / Downs $4,081.72 EA - 5 $20,408.60Taps $5,639.63 EA - 28 $157,909.64

Price per side $599,100.23Price Both sides $1,198,200.46

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 142: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 142

Conductor to Bus Duct Comparison

Results:

Existing: $707,906.48

Aluminum Alternate: $467,089.54

Copper Bus: $1,389,427.93

Aluminum Bus: $1,198,200.46

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 143: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 143

3D Coordination and Clash Detection

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 144: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 144

3D Coordination and Clash Detection

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 145: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 145

3D Coordination and Clash Detection

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and ConclusionsZero

clashes

Page 146: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 146

SIPS Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 147: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 147

SIPS Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 148: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 148

SIPS Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 149: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 149

Interior fit out of each floor divided into six regions of equal work

SIPS Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 150: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 150

Interior fit out of each floor divided into six regions of equal work

Allowed for tighter stacking of trades

SIPS Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 151: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 151

Interior fit out of each floor divided into six regions of equal work

Allowed for tighter stacking of trades

• SIPS production method employed to reduce fit out time

• Trades move from one region to the next in succesion

SIPS Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 152: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 152

New schedule

SIPS Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 153: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 153

New schedule

SIPS Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 154: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 154

Relation to entire building construction?

SIPS Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 155: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 155

SIPS – Redesign Sequencing Existing Sequencing

Building Overview

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Mechanical

Electrical

Coordination

SIPS Sequencing

Results and Conclusions

Page 156: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 156

Building Overview

Team Workflow

Phase I : Façade

Phase II: Cogeneration

Phase III: Lateral System

Phase IV: Distribution Systems

and Coordination

Results and Conclusions

Conclusions

Page 157: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 157

Phase I:

Reduced number of fixtures by about 50%

Dimming increased energy savings/decreased load

Minimized direct solar glare

Maintained building transparency

Reduced the annual energy consumption by 23%

Phase II:

Allowed for a cap to be placed on purchased peak

electrical demand

Increased the installed electric generating capacity from

1400 kW to 3265 KW

Reduced the annual building operating costs by 20%

compared to the existing CHP system

Phase III:

Redesigned lateral system eliminates inherent

torsion and reduces required steel by 3.5%

Elimination of 51st floor outrigger creates two

additional rentable floors to bring in revenue

New York Times Building could be at risk for

progressive collapse

Phase IV:

Bus ducts not a cost effective option

Replaced existing UFAD system

Chose DOAS with ACBs because of reduced

space requirements and superior thermal comfort

Zero system clashes were found on the first

clash detection analysis due to coordination

process

Achieved a 177 day schedule reduction for the

interior fit out portion of the project

Financial Summary:

Phase I: Façade Redesign

Material Labor Typical Floor CostTotal

Building Cost

Existing Façade $810,414 $45,383,218 $1,606,293 $83,527,260

Redesigned Façade $1,343,285 $75,223,990 $2,153,700 $120,607,208

Difference -$532,871 -$29,840,772 -$547,407 -$37,079,948

Phase II: Cogeneration

Plant Redesign

Equipment Cost LaborAnnual Operating

Costs

Payback

Period

Existing CHP Plant $3,673,500.00 $114,750.00 $10,983,700.00 -

Redesigned CHP Plant $6,708,800.00 $255,000.00 $8,773,200.00 3.15 Years

Difference -$3,035,300.00 -$140,250.00 +$2,210,500.00

Thank You

Industry Partners

Thornton Tomasetti Turner Construction

Amec The New York Times

Flack + Kurtz PSU OPP

AE FacultyDr. Chimay Anumba Professor Robert Holland

Dr. Andres Lepage Professor M. Kevin Parfitt

Dr. Jelena Srebric Dr. Kevin Houser

Dr. Richard Mistrick Dr. John Messner

Dr. Jim Freihaut Jim Faust

Family and Friends

Page 158: 4.14.2010 TEAM II: B | C | W F… · 4.14.2010 TEAM II: BONFANTI | CLARKE | COX | WIACEK 2 Building Overview Team Workflow Phase I : Façade Phase II: Cogeneration Phase III: Lateral

TEAM II: BONFANTI | CLARKE | COX | WIACEK4.14.2010 158

Thank You