INSTALLATION 1. Remove the control cover assembly by turning the locking lever to the unlock position. 2. Insert nut into the slot located above the bypass valve disc (Figure 1). OPERATION Tightening the adjusting screw forces the Bypass Flapper open and blends unconditioned water into the treated water supply. Continue to tighten adjusting screw to increase the volume of unconditioned water that is blended is into the water supply. Loosen the adjusting screw to allow the Bypass Flapper to close. Continue to loosen the adjusting screw to decrease the volume of unconditioned water that is blended into the water supply. To blend a certain amount of hardness back into the water, adjust the screw and test the water. Repeat the procedure as needed until the desired hardness level is reached. 360 Blending Valve Kit Instruction Manual 3. Insert adjusting screw through top plate and thread through the nut. 4. Tighten the screw until it contacts the bypass flapper.

Upload: others

Post on 28-Jun-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 360 Blending Valve Kit - pentair.com

INSTALLATION

1. Remove the control cover assembly by turning the locking lever to the unlock position.

2. Insert nut into the slot located above the bypass valve disc (Figure 1).

OPERATION

Tightening the adjusting screw forces the Bypass Flapper open and blends unconditioned water into the treated water supply. Continue to tighten adjusting screw to increase the volume of unconditioned water that is blended is into the water supply.Loosen the adjusting screw to allow the Bypass Flapper to close. Continue to loosen the adjusting screw to decrease the volume of unconditioned water that is blended into the water supply.

To blend a certain amount of hardness back into the water, adjust the screw and test the water. Repeat the procedure as needed until the desired hardness level is reached.

360 Blending Valve KitInstruction Manual

3. Insert adjusting screw through top plate and thread through the nut.

4. Tighten the screw until it contacts the bypass flapper.

Page 2: 360 Blending Valve Kit - pentair.com

INSTALACIÓN

1. Retire la tapa protectora girando el mando de desbloqueo situado en la parte inferior del frontal de la válvula.

2. Inserte la pequeña pletina roscada (tuerca) en la ranura situada por encima de la válvula nº 5. (Figura 2).

3. Inserte el tornillo de ajuste a través de la guía superior y roscarlo a la tuerca de la pletina.

AJUSTE DUREZA RESIDUAL

Al apretar el tornillo abriremos la válvula de clapeta que controla el bypass generando una mezcla de agua sin tratar con agua descalci-ficada. Cuanto más apretemos, mayor cantidad de agua sin tratar mezclaremos con el agua descalcificada resultando una dureza residual mayor. Afloje el tornillo para cerrar la mezcla de agua con el agua descalcificada. Si desea agua a 0 ºhf el tornillo no deberá tocar la válvula de clapeta.

Para un buen ajuste de la dureza residual se recomienda roscar el tornillo hasta tocar la válvula de clapeta y a partir de este punto apretar una vuelta completa el tornillo. Dejar pasar agua a través del equipo descalcificador por un grifo de servicio (preferiblemente el mas cercano a la salida del descalcificador) con el fin de purgar la tu-bería. Analizar para ver el resultado de la mezcla y corregir el exceso o defecto de la misma abriendo o cerrando el tornillo mezclador.La dureza residual recomendada en instalaciones domesticas es entre 6-10 ºhf (60-100 mg/l).

4. Apriete el tornillo hasta que haga contacto con la válvula de clapeta (figura 3). Y ajuste la dureza residual deseada.

5. Coloque de nuevo la tapa de protección y bloquéela.

Kit ajuste dureza residual matrix - 360Manual de instrucciones

4002315 Rev A JL12