3_5_ark - non return damper

9
Non Return Dampers Type ARK · ARK1 Pressure Relief Damper Type ARK2 3/5/EN/3 TROX GmbH T elephone + 49 / 2845 / 2 02-0 T elefax +4 9/2 845/202-265 Heinrich- T rox-Platz e-mail trox@trox.de D-47504 Neukirchen- Vluyn www.troxtechnik.com

Upload: blindjaxx

Post on 03-Apr-2018

223 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 3_5_ark - Non Return Damper

7/28/2019 3_5_ark - Non Return Damper

http://slidepdf.com/reader/full/35ark-non-return-damper 1/8

Non Return DampersType ARK · ARK1

Pressure Relief DamperType ARK2

3/5/EN/3

TROX GmbH Telephone +49/28 45/2 02-0Telefax +49/2845 /202-265

Heinrich-Trox-Platz e-mail [email protected]

D-47504 Neukirchen-Vluyn www.troxtechnik.com

Page 2: 3_5_ark - Non Return Damper

7/28/2019 3_5_ark - Non Return Damper

http://slidepdf.com/reader/full/35ark-non-return-damper 2/8

Contents · Description

Description 2

Construction 3

Standard sizes · Installation details 5

Technical data 6Order details 7

2

Type ARK (with linked blades) to be used in systems with

variable air volume.

Type ARK1 (with adjustable stops to limit the blade openingangle) to be used in systems with constant air volume.

Permitted installation orientation: horizontal and vertical

Type ARK2 (with factory-set permanent magnets for lockingthe blades in closed position) to be used in ventilation systemsand rooms of buildings in case of over pressure risks.

Permitted installation orientation: horizontal

 ARK ARK1

 ARK2

Non return dampers type ARK and ARK1 are designed forautomatic shut off of individual sections of an air conditioningsystem. With fan running, the degree of blade opening is afunction of the air velocity. If the fan is turned off, the blades

close automatically. In a multi fan installation this prevents backdraught through the non-operating fans.

Pressure relief dampers type ARK2 are used in ventilationsystems and rooms of buildings to prevent excess pressuresoccuring. If a specified pressure difference is exceeded thedamper blades automatically open to relieve the excesspressure. Pressure peaks, e.g. resulting from rapidly closingfire dampers or shut-off dampers, will be reliably controlled.

Page 3: 3_5_ark - Non Return Damper

7/28/2019 3_5_ark - Non Return Damper

http://slidepdf.com/reader/full/35ark-non-return-damper 3/83

Construction

Type ARK 

Type ARK1

Type ARK · ARK1

 ARK – Casing formed from galvanised sheet steel;

casing in stainless steel on request

– Aluminium blades– Coupling sections (with dampers having two or more blades)

made of aluminium– Blade shafts stainless steel– Bearing from composite material with antifriction lining of

PTFE/Pb (maintenance-free)– Seals made of neoprene, temperature resistant up to 80°C– Limiting pressure 5000 Pa

Construction variant ARK-G As for type ARK, but both flanges drilled

 ARK1 As for type ARK, but:– without blade coupling sections– with stops to limit blade opening angle, which are adjustable

externally

Construction variant ARK1-G As for type ARK1, but both flanges drilled

ቢ Casingባ Bladeቤ

Sealብ Stop angle

ቦ Blade shaft

ቧ Bearingቨ Blade coupling sectionቩ

 Adjustable stop(2 elements per blade)

B

B

   H

   H

180

max. 200

   3   8

ቦ ቧ

ቦ ቧ

180

   3   8

ቦ ቧ

Surface finish

Powder coating P1Standard RAL shades: RAL 9010-GE50*, RAL 9006-GE30*,

RAL 9001, RAL 9002, RAL 9003,RAL 9005, RAL 9016, RAL 7001,RAL 7035 – all GE70*

Other shades on request

* GE = Gloss level

Page 4: 3_5_ark - Non Return Damper

7/28/2019 3_5_ark - Non Return Damper

http://slidepdf.com/reader/full/35ark-non-return-damper 4/8

Construction

4

Type ARK2

Damper locked Damper unlocked

Type ARK2

 ARK2– Casing formed from galvanised sheet steel;

casing in stainless steel on request– Aluminium blades– Blade shafts stainless steel– Bearing from composite material with antifriction lining of

PTFE/Pb (maintenance-free)– Seals made of neoprene, temperature resistant up to 80°C– Opening pressure difference 50-1000 Pa for dampers up to

a width of 600 mm– Opening pressure difference max. 600 Pa for dampers

with a width greater than 600-1200 mm– The required opening pressure difference must be specified

when ordering

Construction variant ARK2-G As for type ARK2, but both flanges drilled ቢ Casing

ባBladeቤ Seal

ብ Stop angle

ቦ Blade shaftቧ

Bearingቪ Permanent magnet

ባ ቪ ባ ቪ

B

   H

180

max. 235

   3   8

ቦ ቧ

Surface finish

Powder coating P1Standard RAL shades: RAL 9010-GE50*, RAL 9006-GE30*,

RAL 9001, RAL 9002, RAL 9003,RAL 9005, RAL 9016, RAL 7001,RAL 7035 – all GE70*

Other shades on request

* GE = Gloss level

Page 5: 3_5_ark - Non Return Damper

7/28/2019 3_5_ark - Non Return Damper

http://slidepdf.com/reader/full/35ark-non-return-damper 5/85

Standard Sizes · Installation Details

Flange drilling details

even number of holes

odd number of holes

For construction using masonry subframe, the casing flanges aredrilled on both sides.

By using special screws in the masonry subframe, the non returndamper or pressure relief damper can easily be demounted ormounted even when subframe is fitted in the wall.

Scope of supply masonry subframe:Galvanised angle steel masonry subframe 35/35/3; builders cleats(screw-on type), special screws, screws, nuts and washers made ofgalvanised steel (installation on site, by others).

Installation on surface of wall opening Installation between ventilation ducts

Detail X 

B20

л 9.5

   2   0

   H

   H

   /   B

   H

  +   2   0   /   B  +   2   0

 X 

   H

   /   B

Type ARK2 shown

Installation opening without masonry subframe B / H

Type ARK2 shown

   H   /   B

Masonry subframe

Special screw

Masonry subframe

with one masonry subframe 22

Construction Code

Hole pitch B- and H-dimensions = 125 mm

Standard sizes

200 345 1 – 2 4400 675 2 1 4 6

600 1005 3 1 5 9

800 1335 4 2 7 12

1000 1665 5 2 8 14

1200 1995 6 2 10 17

B H Number of Number of Number of holes

in mm in mm blades bladecoupling per B- per H-sections * dimension dimension

 Any combinations of dimensions B x H listed above can be supplied.Intermediate dimensions on request. * only with type ARK

Inlet cross-section A in m2

345 0.069 0.138 0.207 0.276 0.345 0.414

675 0.135 0.270 0.405 0.540 0.675 0.810

1005 0.201 0.402 0.603 0.804 1.005 1.206

1335 0.227 0.454 0.681 0.908 1.135 1.362

1665 0.333 0.666 0.999 1.332 1.665 1.998

1995 0.399 0.798 1.197 1.596 1.995 2.394

H in mm B in mm200 400 600 800 1000 1200

Page 6: 3_5_ark - Non Return Damper

7/28/2019 3_5_ark - Non Return Damper

http://slidepdf.com/reader/full/35ark-non-return-damper 6/8

Technical Data

6

Nomenclature

B in mm: Width

H in mm: Height

 A in m2: Inlet cross-section (see page 5)v in m/s: Air velocity with damper opened based on inlet

cross-section A 

pt in Pa: Total pressure drop (duct mounting) withdamper open

pD in Pa: Pressure difference with damper closed

V· L in l/s: Leakage volume flow ratein m3 /h: (independent of width B)

pÖ in Pa: Opening pressure difference

V· in m3 /h: Resulting volume flow

Example 1

Data given: Non return damper type ARKB = 600 mm, H = 1005 mm

pD

= 2000 Pa, v = 7 m/sHorizontal installation orientation

Required: Total pressure drop ptLeakage volume flow V· L

Result: (from diagram) pt = 100 Pa

V· L = 1.3 l/s (4.7 m3 /h)

Example 2

Data given: Pressure relief damper type ARK2 – 1000 PaB = 600 mm, H = 1005 mm, A = 0.6 m2

pÖ = 1000 Pa, v = 2 m/sRequired: Total pressure drop pt with damper open

Resulting volume flow V·

Result: pt = 50 Pa (from diagram)V· = v · A · 3600 = 2 · 0.6 · 3600 = 4320 m3 /h

Pressure drop type ARK · ARK1 Pressure drop type ARK2

Installation orientation

v v

       p

   t

       p

   t

140 100

80

60

Pa

40

20

0

120

100

Pa

80

60

40

20

00 1 2 m/s 3 4 52 4 6 8 10m/s

1

1

2

Leakage volume flow type ARK · ARK1

H

V.L

       p

   D

345 mm 675 1005 1335 1665 19955000

4000

Pa

3000

2000

1000

5000.5

2 4 6 m3 /h 8 10 12

1 1.5 l/s 2 2.5 3 3.5

1horizontal duct

(graph 1)

2vertical duct

(graph 2)

3horizontal duct

       p

   t

   

  p   t

       p

   D

Installation orientations

Pressure drop 1 + 2 1 + 2 1

Leakage volume flow 3 3 –

Diagram Type ARK Type ARK1 Type ARK2

Page 7: 3_5_ark - Non Return Damper

7/28/2019 3_5_ark - Non Return Damper

http://slidepdf.com/reader/full/35ark-non-return-damper 7/87

Order Details

Type designation ARK ARK1

Construction variant

Standard sizesB x H1 in mm(see page 5)

Order code These codes need not be completed for standard products

 / / / /  ARK-G 600 x 1005 22 P1 RAL 9010

Specification textPressure relief dampers with permanent locking magnet to protectventilation systems and rooms in buildings against overpressure.

Opening pressure difference 50-1000 Pa for dampers up to a widthof 600 mm

Opening pressure difference max. 600 Pa for dampers with a widthgreater than 600-1200 mm

Material and construction variants:details see page 4

Masonry subframe:details see page 5

Make: TROX

Type: ARK2

Order exampleMake: TROXType: ARK2-G / 600 x 1005 / 22 / 1000 Pa / P1 / RAL 9010Qty.: 4

Specification textNon return dampers for automatic shut off of individual sectionsof an air conditioning system, permitted maximum pressure loading5000 Pa (acting in closing direction).

Material and construction variants:details see page 3

Masonry subframe:details see page 5

Make: TROX

Types: ARK · ARK1

Order exampleMake: TROXType: ARK-G / 600 x 1005 / 22 / P1 / RAL 9010Qty.: 4

Masonry subframe (see page 5)220 = without masonry subframe

Surface (see pages 3 and 4)P1 = Powder-coated to RAL ...

Colour shade (see pages 3 and 4)RAL ...

P1 RAL 9010

Surface (see pages 3 and 4)P1 = Powder-coated to RAL ...

Colour shade (see pages 3 and 4)RAL ...

Type designation ARK2

Construction variant

Standard sizesB x H1 in mm(see page 5)

These codes need not be completed for standard products

 ARK2-G 600 x 1005 22 …Pa

Masonry subframe (see page 5)

220 = without masonry subframe

Opening pressure differenceSpecification in Pa

   D  e  s   i  g  n  c   h  a  n  g  e  s  r  e  s  e  r  v  e   d  ·   A   l   l  r   i  g   h   t  s  r  e  s  e  r  v  e   d   ©

   T   R   O   X   G  m   b   H   (   0   8   /   2   0   0   8   )

 / / / / / 

Page 8: 3_5_ark - Non Return Damper

7/28/2019 3_5_ark - Non Return Damper

http://slidepdf.com/reader/full/35ark-non-return-damper 8/8