255 valve specifications - performance water

6
imagination at work 255 Valve Specifications

Upload: others

Post on 08-Jan-2022

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 255 Valve Specifications - Performance Water

imagination at work

255 Valve Specifications

Page 2: 255 Valve Specifications - Performance Water

Flow Rates (Valve Only)Service @ 15 psi (1.03 bar) drop . . . . . . . . . . . . . . . . . . . . . . . 15.5 gpm (3.52 m3/h)Backwash @ 25 psi (1.72 bar) drop. . . . . . . . . . . . . . . . . . . . . 6.0 gpm (1.36 m3/h)Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cv = 3.99 (Kv = 3.4)Backwash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cv = 1.20 (Kv = 1.0)Note: Tested with a 3/4-inch brass manifold

Valve Connections/DimensionsTank Thread. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1/2-inches – 8, maleInlet/Outlet Manifold (Brass or Noryl®). . . . . . . . . . . . . . . . . 1-inch NPT or BSPT, female

3/4-inch NPT or BSPT, female3/4-inch NPT or BSPT, male, Noryl®

1/2-inch NPT or BSPT, male, Noryl®

Drain Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2-inch (manifold dependent)Brine Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4-inch or 3/8-inch NPT, male; air check built into valveDistributor Tube Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.050 inches (27 mm) or 13/16-inch (20.6 mm)Distributor Tube Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/8 ± 1/8 inches (29 mm ± 3 mm) above top of tank

Design Specifications/RatingsValve Body . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glass-filled Noryl® – NSF listed materialRubber Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compounded for cold water – NSF listed materialsValve Materials Certification . . . . . . . . . . . . . . . . . . . . . . . . . . NSF/ANSI 44 rated component for material safetyWeight (Valve with Control). . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Ibs (1.8 kg)Recommended Operating Pressure . . . . . . . . . . . . . . . . . . . . 20 - 120 psi (1.38 - 8.27 bar)

Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 - 100 psi (1.38 - 6.89 bar)Hydrostatic Test Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 psi (20.69 bar)Water Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35° - 100°F (2° - 38°C)Ambient Temperature* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35° - 120°F (2° - 48.9°C)*Recommended use of outdoor cover for direct sunlight applications

OptionsTurbine for Demand Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard manifold, 1-inch Autotrol turbineBypass Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Noryl®, 1-inch flow path, 1/2-inch (13mm) NPT male, drain

Bypass Inlet-Outlet Fitting Kits:Copper, Sweat Tube Adapter . . . . . . . . . . . . . . . . . . . . . . . . 1-inch or 3/4-inch (25 mm or 19 mm)CPVC, Solvent Weld Tube Adapter . . . . . . . . . . . . . . . . . . 1-inch or 3/4-inch (25 mm or 19 mm)Plastic NPT or BSPT Pipe Adapter . . . . . . . . . . . . . . . . . . . 1-inch male or 3/4-inch male (25 mm or 19 mm)Brass NPT or BSPT Pipe Adapter . . . . . . . . . . . . . . . . . . . . 1-inch male or 3/4-inch male (25 mm or 19 mm)Brine Refill Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 gpm (1.25 Lpm) fixed

.17 gpm (.64 Lpm) fixed – optional for small tank applications1-10 lbs (0.45 - 4.5 kg) – 400 series controllers3-19 lbs (1.3 - 8.6 kg) – 400 series controllers

Compatible with Regenerants/Chemicals. . . . . . . . . . . . . . Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite†, sodium hydroxide†,hydrochloric acid†, chlorine†† and chloramines††

Specifications

2

✝ See owners manual for specific concentrations✝✝Valve for use on potable water supply

Page 3: 255 Valve Specifications - Performance Water

Injector* Performance – Logix Series Controllers

0.08

0.07

0.06

0.05

0.04

0.03

0.02

0.01

0.00

M3/hr gpm

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.00 LWR6057

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

TOTAL BRINE DRAW RINSE

Injector “F” (Peach)For 7-inch Tanks

0.11

0.10

0.09

0.08

0.07

0.06

0.05

0.04

0.03

0.02

0.01

0.00

M3/hr gpm

0.50

0.40

0.30

0.20

0.10

0.00LWR6057

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

TOTAL BRINE DRAW RINSE

Injector “G” (Tan)For 8-inch Tanks

0.16

0.14

0.12

0.10

0.08

0.06

0.04

0.02

0.00

M3/hr gpm

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00 LWR6151

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

TOTAL BRINE DRAW RINSE

Injector “H” (Light Purple)For 9-inch Tanks

0.18

0.16

0.14

0.12

0.10

0.08

0.06

0.04

0.02

0.00

M3/hr gpm

0.80

0.60

0.40

0.20

0.00 LWR6151

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

TOTAL BRINE DRAW RINSE

Injector “J” (Light Blue)For 10-inch Tanks

0.25

0.20

0.15

0.10

0.05

0.00

M3/hr gpm

1.20

1.00

0.80

0.60

0.40

0.20

0.00 LWR6151

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

TOTAL BRINE DRAW RINSE

Injector “K” (Pink)For 12-inch Tanks

0.30

0.20

0.10

0.00

M3/hr gpm

1.50

1.25

1.00

0.75

0.50

0.25

0.00 LWR6164

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

TOTAL BRINE DRAW RINSE

Injector “L” (Orange)For 13- and 14-inch Tanks

*New injectors for high-efficiency regeneration sequence are standard with Logix Controllers.

NOTE: Actual injector performance is dependent on the resin used, tank geometry, elevated drain, etc. This injector data was taken using an empty tank (no resin).

3

Page 4: 255 Valve Specifications - Performance Water

Backwash Flow Rate Flow RateNumber** (gpm) (lpm)

7 1.3 4.9

8 1.7 6.4

9 2.2 8.3

10 2.7 10.2

12 3.9 14.76

13 4.5 17.0

14 5.3 20.0

**Backwash flow controls sized for 5.0 gpm/ft2

Backwash Flow Control Table

Injector “A” (White)

Injector “B” (Blue)

Injector “C” (Red)

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.00

M3/hr gpm

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

TOTAL BRINE DRAW RINSE

1.80

1.60

1.40

1.20

1.00

0.80

0.60

0.40

0.20

0.00 LWR4669

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.00

M3/hr gpm

1.80

1.60

1.40

1.20

1.00

0.80

0.60

0.40

0.20

0.00 LWR4669

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

TOTAL BRINE DRAW RINSE

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.00

M3/hr gpm

1.80

1.60

1.40

1.20

1.00

0.80

0.60

0.40

0.20

0.00 LWR4669

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

TOTAL BRINE DRAW RINSE

4

400 and 900 Series Controllers

P

R

E

S

S

U

R

E

D

R

O

P

F L O W R A T E

255 SERVICE FLOW

– Cv = 3.99

255

BACK

WAS

HFL

OW

–Cv

=1.

20

LWR 4630 SVCLWR 5236 BW

2 64 8 10 12 16140

m3/h

gpm

0.9 1.4 1.80.50 2.3 2.7 3.2 3.6

1.10

1.00

0.90

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00

bar psi

16

14

12

10

8

6

4

2

0

Flow Rate Characteristics

Page 5: 255 Valve Specifications - Performance Water

5

Electrical SpecificationsController Operating Voltage 12 Volt – AC (Requires use of GE Infrastructure supplied transformer)

Input Supply Frequency 50 or 60 Hz (Controller configuration dependent)

Motor Input Voltage 12 Volt – AC

Electronics Operating Voltage (Logix Series) 3.5 Volt – AC

Controller System Power Consumption 3 Watts average

Transformer Specifications – All ControllersAll Controllers require the use of a GE Infrastructure supplied transformer.

Transformer Output Voltage 12 Volt – AC 400mA

Transformer Input Options 115 Volt – AC 50/60 Hz; 230 Volt – AC 50/60 Hz; 100 Volt – AC 50/60 Hz

Transformer Plug Options Indoor North American Plug

Outdoor North American (UL Listed for outdoor use)

Japanese Plug

Taiwan/Korea Plug

Australian Plug

United Kingdom Plug

Mainland Europe Plug

Additional transformers may be available – call for more information

Controller Series

400 Series440i Time Clock• Value priced, reliable

mechanical control• Time-clock regeneration• Set it and forget it• 12-volt or 120-volt versions

available• 6- or 7-day regeneration• Operates 255, 263, 268 valves

460i Time Clock• Economical electronic-

demand control• Simple set-up and

programming• Calendar override• 12-volt operation• 7-day variable reserve• Operates 255, 268 valves

Logix Series740 Time Clock• Simple, economic electronic

time clock (chronometric)• 7- or 99-day regeneration

setting• High efficiency regeneration sequence• 12-volt operation• Filter or conditioner setting in one control• Operates 255, 263, 268 with one controller

760 Demand• Simple, economic electronic

demand (volumetric)• Calendar override• 12-volt operation• 28-day variable reserve• High efficiency regeneration sequence• Automatic capacity calculations• Operates 255, 263, 268 with one controller

742 Time ClockSame features as the 740 time clock, plus:• Fully programmable cycle times• Salt setting in 1-pound increments• Optional no-salt detector• Operates 255, 263, 268, 278, and Magnum IT

with one controller

762 DemandSame features as the 760, plus:• Fully programmable cycle times• Salt setting in 1-pound increments• Optional no-salt detector• Operates 255, 263, 268, 278, and Magnum IT

with one controller

GE offers a full range of valve controllers to meet all residential water-conditioning applications.

Page 6: 255 Valve Specifications - Performance Water

imagination at work

For More Information:Call GE Infrastructure Water & Process Technologies;Household Water Group at (262) 238-4400 or (800) 279-9404, or visit www.gewater.com

©2005, General Electric Company.Printed in USA, P/N 1018069 Rev. C

North American Sales5730 N. Glen Park RoadMilwaukee, WI 53209-4403USA(262) 238-4400 Phone(262) 238-4402 Fax

Controller valve manufactured by:

B IHC

E F

G

D

A

K

J

in cmA 14.9 (37.8)B 6.6 (16.8)C 8.2 (20.8)D 8.4 (21.3)E 4.2 (10.7)F 4.0 (10.2)

in cmG 5.7 (34.5)H 3.1 (7.9)I 5.1 (13.0)J 1.5 (3.8)K 1.5 (3.8)

255 Valve – Logix Series Controller

255 Valve Outline DimensionsLogix Series Controllers

255 Valve Dimensions with Logix Cover

K

J

CBL

G

IH

Inlet

Drain

Outlet

F

A

ME

D

in cmA 12.07 (30.6)B 4.80 (12.2)C 5.44 (13.8)D 8.86 (22.5)E 3.50 (8.9)F 6.48 (16.5)

in cmG 9.36 (23.8)H 1.50 (3.8)I 1.50 (3.8)J 8.60 (21.8)K .94 (2.4)L 4.56 (11.6)

400 Series Controllers255 Valve Dimensions with 400 Series Controller

255 Valve – 400 Series Controller