2017955a · 5. when mounting heights are above 30ft., the sensor generally only detects large...
TRANSCRIPT
Tekening-nr :
Artikel-nr :Product-omschrijving :
Buismast "NS" 5.5m-121-60 / VPMast-type "Ledway"
2017955
2017955A-OV
Maat-toll
FormaatA4
Schaalzie tek
Alg.toll. Maateenh.mmDIN 7168 GROF
Amerik.proj.
Tot. bladBlad-nr.
NEN-EN 40-2
2
M2-ctGetekend: PvO/MSN2.26 m²
2
Revisie dd: 14-08-2014Tel : 0416 - 347.057 Fax : 0416 - 561.545Haydnstraat 1 5144 GR Waalwijk
Mast Services Nederland
ALGEMENE VOORWAARDEN: OP AL ONZE LEVERINGEN
BETALINGEN EN/OF TRANSACTIES ZIJN VAN TOEPASSINGDE BETALINGS- EN LEVERINGSVOORWAARDEN ZOALSGEDEPONEERD BIJ DE K.V.K. TE BRABANT
OP VERZOEK WORDT EEN EXEMPLAAR TOEGEZONDEN.
DEZE TEKENING IS EIGENDOM VAN MAST SERVICES
NEDERLAND EN MAG ZONDER HAAR TOESTEMMINGNIET GEBRUIKT, GECOPIEERD EN/OF AAN DERDEN
TER BESCHIKKING WORDEN GESTELD.AUTEURSRECHTEN VOORBEHOUDEN VOLGENS DE WET
5500
MULTI-LEVEL SENSOR OPTION
INSTALLATION INSTRUCTIONS- ENGLISH
1 of 5 CI265X56R0
IMPORTANT SAFEGUARDSWhen using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS1. To avoid the possibility of electrical shock, turn off power supply before installation or servicing.2. Product must be installed in accordance with your local electrical code. If you are not familiar with these codes
and requirements, consult a qualified electrician.3. All electrical connections have been made at the factory.4. The sensor is designed for mounting heights between 10 ft. to 40 ft., see figure 1, 2 and 3 for product specific
coverage pattern.5. When mounting heights are above 30ft., the sensor generally only detects large objects such as forklift trucks.6. When sensor lens assembly is removed the exposed sensor body is sensitive to electrostatic discharge. Take the
necessary steps to avoid possible damage to the sensor.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
SENSOR DESCRIPTION
The occupancy sensor controls high and low light levels based on occupancy and the selected ambient light level setting. The Ambient Light feature can be used to keep the lights from turning to high level if the ambient light level is sufficient.The sensor uses passive infrared sensing
(PIR) technology that reacts to changes in infrared energy (moving heat) within the coverage area. Once the space is vacant and the time delay elapses (adjustable from 30 seconds to 30 minutes), the luminaire will turn off or dim. Sensors must directly “see” motion of an occupant to detect them, so careful consideration must be given to sensor placement. Avoid placement where sensor’s line of sight may be obstructed
IMPORTANT: There is an initial warm-up period. It may take up to a minute before the lights turn on due to a sensor warm–up period required during initial power- up. This occurs during installation or after a lengthy power failure only.
COVERAGE PATTERN
The density and the range of the coverage pattern is determined by the supplied lens and mounting height. For standard lenses and patterns for EDGE Area and LEDway Streetlight (and SLM and XSP) See Figure 1. For EDGE Canopy and 304 Series Floodlight/ Recessed Canopy See Figure 2. For EDGE Security, EDGE Parking Structure and 304 Series Parking Structure. See Figure 3.
1
2
3
2 of 5 CI265X56R0
SENSOR OPERATION
HIGH DIMMING FEATURE (H):The High Dimming feature (Rotary switch H) has eight possible settings. See Figure 5 for the complete range available. NOTE: The sensor will not allow the maximum rated drive current of the luminaire to be exceeded.
LOW DIMMING FEATURE (L):The Low Dimming feature (Rotary switch L) has eight possible settings and can be adjusted from an off position (position 0) to a maximum drive current (position 7). See Figure 5 for the complete range available.
TIME DELAY FEATURE (D):The Time Delay feature (Rotary switch D) has eight possible settings and can be adjusted from 0.5 min (position 0) to 30 min (position 7) - factory set at 4 min (position 3). See Figure 5 for the complete range available. Once motion is detected, the lighting level will remain in high mode until no activity is detected for the duration of the time delay cycle that has been selected.
AMBIENT LIGHT FEATURE (A):The Ambient Light feature (Rotary switch A) has eight possible settings and provides the ability to employ daylight harvesting. It also includes a test mode, as well as lock low and lock high settings. See Figure 5 for complete range available – a more detail description of each setting is below.Occupancy Sensing Only (OSO): Occupancy detection (PIR) enabled only- factory default setting. Ambient Light sensing (ambient photocell ) is disabled. The sensor will switch the luminaire to High mode during occupancy detection regardless of environment light levels and will remain so per selected setting in Time Delay feature. After no occupancy is detected during Time Delay cycle, luminaire will switch to Low mode.
Occupancy Sensing and Time Off (OSTO): Occupancy detection (PIR) enabled only with Time Off operation. Ambient light sensing (ambient photocell) is disabled. The sensor will switch the luminaire to High mode during occupancy detection regardless of environment light levels and will remain so per selected setting in Time Delay feature. After no occupancy is detected during Time Delay cycle, luminaire will switch to Low mode. Sensor will switch the luminaire to Off after 30 minutes of no occupancy detection (Low mode). The luminaire will move immediately back into high mode from off once motion is detected. Occupancy Sensing and Low Ambient (OSLA): Occupancy detection (PIR) and Ambient Light sensing (ambient photocell) enabled. During transitional periods from night to day once environment light levels exceed 130 Lux (12 FC), luminaire will be turned Off regardless of occupancy. During transitional periods from day to night when environment light levels fall below 80 Lux (7 FC), luminaire will switch from OFF to Low mode during no occupancy and switch to High mode after occupancy is detected.Occupancy Sensing and High Ambient (OSHA): Occupancy detection (PIR) and Ambient Light sensing (ambient photocell) enabled. During transitional periods from night to day once environment light levels exceed 600 Lux (55 FC), luminaire will be turned Off regardless of occupancy. During transitional periods from day to night when environment light levels fall below 500 Lux (46 FC), luminaire will switch from OFF to Low mode during no occupancy and switch to High mode after occupancy is detected.Occupancy Sensing, Low Ambient and Time Off (OSLATO): Occupancy detection (PIR), Ambient Light sensing (ambient photocell) and Time Off enabled. During transitional periods from night to day once environment light levels exceed 130 Lux (12 FC), luminaire will be turned Off regardless of occupancy. During transitional periods from day to night
when environment light levels fall below 80 Lux (7 FC), luminaire will switch from OFF to Low mode during no occupancy and switch to High mode after occupancy is detected. Sensor will switch the luminaire Off after 30 minutes of no occupancy detection (Low mode). The luminaire will move immediately back into high mode from off once motion is detected and ambient light is less than approximately 130 Lux (12 FC).Occupancy Sensing, High Ambient and Time Off (OSHATO): Occupancy detection (PIR), Ambient Light sensing (ambient photocell) and Time Off enabled. During transitional periods from night to day once environment light levels exceed 600 Lux (55 FC), luminaire will be turned Off regardless of occupancy. During transitional periods from day to night when environment light levels fall below 500 Lux (46 FC), luminaire will switch from OFF to Low mode during no occupancy and switch to High mode after occupancy is detected. Sensor will switch the luminaire Off after 30 minutes of no occupancy detection (Low mode). The luminaire will move immediately back into high mode from off once motion is detected and ambient light is less than approximately 600 Lux (55 FC). Lock Low Mode (LL): Sensor locks in Low Dimming level indefinitely per dimming switch (L) setting. The occupancy detection (PIR) and Ambient Light (ambient photocell) operation are disabled during the Lock Low mode.Test/Lock High Mode (Test/LH): The sensor turns the fixture on at the low level set by dimming switches. Sensor will cycle every 5 seconds between the specified Low and High dimming settings for 4 complete cycles (Low, High, Low, High) and then locks in High indefinitely. The occupancy detection (PIR) and Ambient Light (ambient photocell) operation are disabled during the Test/Lock High mode
SENSOR FACTORY SETTINGS
WARNING: DO NOT TOUCH THE PASSIVE INFRARED SENSOR BELOW LENS ASSEMBLY
4
3 of 5 CI265X56R0
SENSOR ADJUSTMENTS
NOTE: Adjustments to these settings require the user to remove the sensor lens assembly to access the above features; features are located under the lens assembly. Grasp the lens assembly and turn it counterclockwise a quarter turn. Do not remove the plastic nut; it holds the sensor in place and ensures water seal to the lighting fixture. Adjust the Ambient Level switch settings during daylight hours when ambient light is at desired level. See Figure 5 for the full details of the sensor features.
SENSOR LENS ASSEMBLY LABEL Shown for 700 mA maximum drive current. Other drive current labels not shown.
SENSOR LENS ASSEMBLY LABEL
LabelAmbient Setting Description Position
Setting
Occupancy Sensing
(High/Low)Low Ambient
(OFF at ~ 10 fc)High Ambient
(OFF at ~ 50 fc)Timedto Off
Test/Survey Mode
OSO Occupancy Only (standard factory setting)
0 X
OSTO Occupancy & Timed to Off 1 X X
OSLA Occupancy & Low Ambient (~10 fc) 2 X X
OSHA Occupancy & High Ambient (~50 fc) 3 X X
OSLATO Occupancy, Low Ambient (~10 fc) & Timed to Off
4 X X X
OSHATO Occupancy, High Ambient (~50 fc) & Timed to Off
5 X X X
LL Lock Low 6 X
Test/LH Lock High 7 X
AMBIENT LIGHT FEATURES (ML OPTIONS)
5
4 of 5 CI265X56R0
TROUBLESHOOTING
LIGHTS WILL NOT TURN ON OR GO TO HIGH DIMMING MODELED on sensor does not flash
a. Check all wire connections and verify the ground wire is tightly secured.LED on sensor does flash
a. Check all wire connections and verify the ground wire is tightly secured.b. Check Ambient Light settings. Cover the sensor lens to simulate darkness in the room. If the lights come
on, the Ambient Level needs to be adjusted. For instance, if Ambient Level switch is set in position 2 or 4, ambient light levels higher than this setting will keep lights off. See Testing and Adjusting Ambient Level section for instructions.
LIGHTS WILL NOT TURN OFF OR STAY IN LOW MODE
STEP 1:Remove lens. Grasp the lens and turn it counterclockwise a quarter turn.
STEP 2:Check Time Delay switch settings and turn it to position 0 (0.5 min).
STEP 3:Check Ambient Light setting and turn it to position 0 (OSO) and leave controlled area. The fixture should turn off or stay in low mode.
STEP 4:If fixture does not turn off or stay in low mode, call 1-800-236-6800 for technical support.
TESTING OCCUPANCY SENSOR – HIGH AND LOW DIMMING FEATURES
STEP 1:Turn fixture off.
STEP 2:Remove lens assembly. Grasp the lens assembly and turn it counterclockwise a quarter turn.
STEP 3:Turn Ambient Light switch to test mode, position 7.
STEP 4:Turn fixture on.
STEP 5:The fixture should turn on and cycle every 5 seconds between the high and low dimming settings for 4 complete cycles.
STEP 6:Return Ambient Light switch to desired position.
TESTING SENSOR DETECTION OPERATION
STEP 1: Remove lens assembly. Grasp the lens assembly and turn it counterclockwise a quarter turn.
STEP 2: Turn Time Delay switch to position 0 (0.5 min).
STEP 3: Turn Ambient Light switch to position 0 (OSO).
STEP 4:Leave controlled area and let the fixture turn off or go to low mode.
STEP 5: Enter the controlled area, fixture should turn on or go to high mode.
STEP 6:Adjust sensor to desired settings and replace sensor lens assembly.
5 of 5 CI265X56R0
www.cree.com/lighting
© 2013 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See www.cree.com/lighting for warranty and specifications. Cree® and the Cree logo are registered trademarks.
MULTI-LEVEL OPTION OUTPUT MULTIPLIERSLEDway
GENERATION D
DriveCurrent
mA
SystemWatts
Multiplier
SystemLumen
Multiplier
L70 life(Hours)
Hrs @ 25°C
50K hours LumenMaintenance
Level m@ 15° C
75 0.12 0.30 > 150K 102%
125 0.22 0.37 > 150K 101%
150 0.27 0.41 > 150K 101%
175 0.32 0.45 > 150K 100%
225 0.41 0.52 > 150K 99%
275 0.51 0.60 > 150K 98%
325 0.60 0.67 > 150K 97%
350 0.66 0.71 > 150K 96%
425 0.80 0.82 > 150K 95%
475 0.89 0.90 > 150K 94%
525 1.00 1.00 > 150K 93%
550 1.04 1.01 > 150K 93%
575 1.08 1.05 > 150K 92%
625 1.18 1.12 > 150K 91%
700 1.34 1.25 145K 89%
MULTI-LEVEL OPTION OUTPUT MULTIPLIERS
THE EDGE
GENERATION D
DriveCurrent
mA
SystemWatts
Multiplier
SystemLumen
Multiplier
L70 life(Hours)
Hrs @ 25°C
50K hours LumenMaintenance
Level m@ 15° C
75 0.19 0.46 > 150K 103%
125 0.33 .56 > 150K 101%
150 0.40 0.61 > 150K 101%
175 0.48 0.66 > 150K 100%
225 0.62 0.76 > 150K 98%
275 0.77 0.86 > 150K 97%
325 0.91 0.96 > 150K 95%
350 1.00 1.00 > 150K 94%
425 1.20 1.16 > 150K 92%
475 1.35 1.26 > 150K 91%
525 1.51 1.40 140K 88%
550 1.56 1.41 110K 89%
575 1.64 1.46 100K 88%
625 1.78 1.56 95K 86%
700 2.03 1.71 90K 84%
MULTI-LEVEL OPTION OUTPUT MULTIPLIERS304 SERIES
GENERATION D
DriveCurrent
mA
SystemWatts
Multiplier
SystemLumen
Multiplier
L70 life(Hours)
Hrs @ 25°C
50K hours LumenMaintenance
Level m@ 15° C
75 0.19 0.42 > 150K 102%
125 0.33 0.52 > 150K 101%
150 0.40 0.57 > 150K 101%
175 0.48 0.63 > 150K 100%
225 0.62 0.73 > 150K 99%
275 0.77 0.84 > 150K 98%
325 0.91 0.94 > 150K 97%
350 1.00 1.00 > 150K 96%
425 1.20 1.15 > 150K 95%
475 1.35 1.26 > 150K 94%
525 1.51 1.40 > 150K 93%
550 1.56 1.41 > 150K 93%
575 1.64 1.47 > 150K 92%
625 1.78 1.57 > 150K 91%
700 2.03 1.75 145K 89%
POWER DATA
Note: Multipliers are for estimating purposes only; check the actual Spec Sheet data when adjusting drive current.
When the sensor settings are changed, it will impact both the power consumption and the fixture light output. In order to achieve the ideal settings for the intended application, consult the following data sheet and the appropriate product specification sheet.
Ph. +39 055 343081 Fax +39 055 34308200www.cree-europe.com
Rev. Date: 14 March 2014
Product DescriptionLuminaire housing is all aluminum construction. All components are mercury free and recyclable. Sharp profile for low wind exposure. Tooless entry. Provided with a tenon mounting system that allows for direct arm or pole-top installation (90°) on cylindrical poles and arms with a diameter of 60mm. The adjustable bracket allows the fixture to be tilted by increments of 5° in order to maintain a horizontal position with respect to the ground, making it ideal for retrofit installations as well.
Performance Summary
Utilizes BetaLED® Technology
Patented NanoOptic® Product Technology
CRI: Minimum 70 CRI
CCT: 5700K (+/- 500K) Standard, 4000K (+/- 300K)
Warranty†: Class 1 - 10 years on luminaire/10 years on Colorfast DeltaGuard® finish Class 2 - 5 years on luminaire/10 years on Colorfast DeltaGuard® finish
AccessoriesField Installed Accessories
BRDSPK30 Bird Spikes for Light Engine, 20-30 LEDs
BRDSPK60 Bird Spikes for Light Engine, 40-60 LEDs
BRDSPK120 Bird Spikes for Light Engine, 80-120 LEDs
BRDSPKHSG Bird Spikes for Housing
KIT ADATT. PALO 34MM Adaptor Kit for dia. 34mm poles
KIT ADATT. PALO 42MM Adaptor Kit for dia. 42mm poles
KIT ADATT. PALO 48MM Adaptor Kit for dia. 48mm poles
LEDway® Road
A
270 mm
272 mm218 mm
119 mm
78 mm
78 mm
A
270 mm
272 mm
119 mm
108 mm
195 mm
78 mm
A
270 mm
272 mm218 mm
119 mm
78 mm
78 mm
A
270 mm
272 mm
119 mm
108 mm
195 mm
78 mm
A
270 mm
272 mm218 mm
119 mm
78 mm
78 mm
A
270 mm
272 mm
119 mm
108 mm
195 mm
78 mm
* Light engine portion of extrusion is not painted and will remain natural aluminum regardless of color selection† See www.cree.com/lighting for warranty terms ** Not available in Class 2
LED Count Dimension Measurement
20
"A"
156mm
270mm
30
40
Weight
552mm
552mm
120
110
100
90
80
60
50
552mm
552mm
552mm
270mm
270mm
156mm
7,52kg
7,92kg
9,22kg
10,42kg
10,52kg
14,72kg
14,82kg
14,92kg
15,02kg
15,12kg
L X D 7 02 E G SV I5
ProductInsulation
ClassModel Optic Mounting
LED Count (x10)
VersionOptions
(consult company for available options)Color
Options*Drive
Current
LEDway XClass 1
YClass 2
D Road
7 02030405060809101112
E No code 5700K43 4000K K# Light Control with Occupancy Sensor** - Flux dimming control with occupancy sensorD# Power Line Communication System (PLC) - Power line control system with dimmable driver G# Bi-Level Control - Two distinct power levels, High/LowD Dimmable Driver - Dimmable driver 1-10V with external controllerS# Virtual Midnight - Two levels option with virtual midnight - Available up to 100 LEDs in class 1 - Available up to 60 LEDs in class 2T# Reprogrammable Virtual Midnight - Reprogrammable 2 levels option with virtual midnight R# Flux Dimming - Integral dimming system with plants including flux regulators - Available up to 100 LEDs in class 1 - Available from 80 to 120 LEDs in class 2
SVSilver
(Standard)
BKBlack
BZBronze
SBSilver
Bronze
WHWhite
No Code700mA
I5
525mA
I3350mA
IP66 Street Light – Adjustable Arm Mount – TS (Type II Short)
Ordering InformationExample: LXDTS702EGSVI5
TSType II Short
TS
Ph. +39 055 343081 Fax +39 055 34308200www.cree-europe.com
© 2014 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content subject to change. See www.cree.com/patents for patents that cover these products. Cree®, the Cree logo, BetaLED®, NanoOptic®, and Colorfast DeltaGuard® are registered trademarks, and the BetaLED Technology logo, Precision Delivery Grid™ and LEDway® are trademarks of Cree, Inc. or one of its subsidiaries.
Photometry
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified laboratory.
IES FilesTo obtain an IES file specific to your project, please consult www.cree-europe.com
Maximum Wind Area (lateral surface exposed to wind):
LED Count (x10) Arm Mount Pole Top
Mount
0203
0.051 m2 0.061 m2
040506
0.060 m2 0.070 m2
0809101112
0.080 m2 0.090 m2
Product Specifications
BETALED® TECHNOLOGYLEDway® Road luminaires are powered by BetaLED® Technology delivering outstanding illumination, lasting performance and optimum energy efficiency. Patented NanoOptic® technology optimizes target illumination, performance and offers flexibility with multiple optic choices. NanoOptic compliant with light pollution and photobiological safety standards
CONSTRUCTION & MATERIALS• Housing is all aluminum construction
• Designed with 1-10V dimming capabilities. Controls by others
• Adjustable mounting arm is rugged die cast aluminum and mounts to a 60mm outer dimension tenon
• Exclusive Colorfast DeltaGuard® finish features an E-Coat epoxy primer with an ultradurable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Standard is silver. Bronze, black, white, and silver bronze are also available
ELECTRICAL SYSTEM• Input Voltage: 220 – 240Vac (capable 120-277Vac, please consult
company for available configurations) 50/60Hz
• Power Factor: > 0.9 at full load
• Total Harmonic Distortion: < 20% at full load
• Quick disconnect harness suitable for mate and break under load provided on power feed to driver for ease of maintenance
REGULATORY & VOLUNTARY QUALIFICATIONS• CE Listed
• ENEC Listed only for class II
• Enclosure rated IP66 per IEC 60529
• 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2, for Class I only
• Luminaire and finish are endurance tested to withstand 5,000 hours of elevated ambient salt fog as defined in ASTM Standard B 117
• RoHS Compliant
* Based on fixture operating at 25° C
IP66 Street Light – Adjustable Arm Mount – TS (Type II Short)
0
10
20
20
10
20 2010 10
0
LXDTS704E
cd/klm C0 - C180 C90 - C270 C55 - C235
500 400 300 200 100 0 100 200 300 400 500
75° 75°
60°60°
45° 45°
30°30°15° 15°0°
Test Report #: CESTL-2013-0072 LXDTS704E43Mounting Height: 6mInitial Delivered Lumens: 8058
lux
Effective Flux (lm) - TS (Type II Short) Distribution
LED Count (x10)
5700K 4000K
System Watts220–240V
Total Current (A) 50K Hours Projected Lumen Maintenance
Factor @ 15˚C (59˚F)
L70 Life*(hours) Delivered
Lumens Delivered Lumens 230V
350mA @ 25˚C (77˚F)
94% >150000
02 2276 2208 25 0.1303 3413 3311 35 0.1704 4551 4425 46 0.2105 5689 5519 56 0.2706 6827 6623 66 0.3108 9102 8831 89 0.4209 10240 9934 99 0.4610 11378 11038 108 0.5211 12516 12142 117 0.5812 13654 13246 126 0.62
525mA @ 25˚C (77˚F)
93% 149000
02 3277 3179 37 0.1703 4915 4769 52 0.2404 6554 6358 70 0.3005 8192 7948 86 0.3906 9831 9537 99 0.4508 13107 12716 141 0.5909 14746 14306 157 0.6510 16384 15895 172 0.7411 18023 17485 187 0.8312 19661 19074 203 0.89
700mA @ 25˚C (77˚F)
91% 129000
02 4153 4029 49 0.2303 6229 6043 70 0.3204 8306 8058 91 0.4005 10382 10072 112 0.5206 12459 12087 132 0.6008 16612 16116 183 0.7909 18688 18130 203 0.8610 20765 20145 224 1.0211 22841 22159 243 1.1212 24918 24174 264 1.26