2013517326106709

1
1. Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head screws. 2. When wiring has been completed, attach the front cover to the rear plate. 3.Plug in the cable harness on the PCB (See Figure 3) 4.attach the front cover(See Figure 4) Door Strike Relay NC Door Strike Relay NO Door Strike Relay Com Alarm Switched negative when active To Door EXIT Request Button Then Negative To Door Contact Then To Negative (+) 12VDC Positive Regulated Power Input (-) Negative Regulated Power Input .3. Do not plug the power supply or transformer into the mains until all wiring has been completed and the front cover secured. Contents 2.Specifications 3.Important Information 1.Introduction 4.Mounting 5.Wiring 6.Detailed Programming Guide 6.1 User Settings . 6.2. Relay Setting (Pulse mode, Toggle mode) 6.3. Alarm Settings, Door Detecting 7.To Remove The Alarm 9.Technical Specification 10.Package Listing 8.Resetting To Factory Default Setting 1 1 1 2 2 4 4 5 6 6 7 7 7 Figure 1 NC NO COM RELAY Figure 2 .1. 1. Programmable Functions Relay momentary Relay strike time Pulse mode,Toggle mode Change Codes 1 master, 1000 users 2. Programmable Timers Door relay time 1-99 seconds Alarm time 1-3 minutes 3. Pulse Mode Toggle Mode 4. Wiring Connections Electric lock External bell External Push Switch Magnetic Contacts Alarm 5. 12V DC Metal shell keypad 12 keys with backlight 2.Specifications 3.Important Information If holes are to be drilled before mounting onto a wall, check for hidden cables and/or pipes before drilling. Use safety goggles when drilling or hammering in cable clips. Every effort has been made to provide accurate information, however slight variations can occur. We also reserve the right to make changes for product improvement at any time NOTE: please read these instructions carefully before attempting to install the BC-2000/K2 Internal Interface Circuit 1. Alarm output interface (See Figure 1) 1.Introduction 2. Electric lock interface (See Figure 2) The BC-2000/K2 is a standalone access control, they use the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming is done through the keypad. Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure. The BC-2000/K2 can store 1000 users with card and 4-6 digits password codes.It has one relay output with 3 Amp changeover contacts. ALARM 2K GND R Q .2. 4.Mounting Terminal Wire Connector Function 3 2 1 NO COM NC Blue Purple Orange 8 7 6 5 4 OPEN D_IN 12V ALARM Yellow Brown Red Black Grey 5.Wiring 1.Unplug the cable harness and connect the necessary cables(See Figure 3). 2.Tape any wires that are unused. GND Figure 4 BC-2000 Figure 3 1 2 3 4 5 6 7 8 9 0 # K2 After all wiring is completed and the unit face plate is attached to the back plate, power on, the red LED will be flashing. Power on BC-2000/K2 Quick Reference Programming Guide To enter the programming mode To exit from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code * Master code # 9999 is the default factory master code * 0 New code # New code # The master code can be 4-6 digits long To add a PIN user 1 User ID number # PIN # The ID number is any number between 000 ~ 999.The PIN is any 4-6 digits between 0000 ~ 999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode To add a card user 1 Read Card # Cards can be added continuously without exiting from programming mode To delete a PIN or a card user. 2 User ID number # for a PIN user or 2 Read Card # for a card user Users can be deleted continuously without exiting from programming mode To unlock the door To unlock the door for a PIN user To unlock the door for a card user Enter the PIN then press # Present the card .4. 6.Detailed Programming Guide 6.1 User Settings . To enter the programming mode Note that to undertake the following programming the master user must be logged in To change the master code * Master code # 9999 is the default factory master code 0 New code # New code # The master code is any 4-6 digits To exit from the programming mode * Setting the working mode: Set valid card only users Set valid card and PIN users Set valid card or PIN users 3 0 # by card only 3 1 # by card and PIN together 3 2 # by either card or PIN (default) To set a user in either card or PIN mode ( 3 2 # ) (Default setting) To add a PIN user 1 User ID number # PIN # The ID number is any number between 000-999. The PIN is any 4-6 digits between 0000-999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting from programming mode as follows: 1 User ID no 1 # PIN # User ID no 2 # PIN # To delete a PIN user 2 User ID number # Users can be deleted continuously without exiting programming mode To change the PIN of a PIN user (This step must be done out of programming mode) * ID number # Old PIN # New PIN # New PIN # To add a card user (Method 1) This is the fastest way to enter cards using ID number auto generation. 1 Read card # Cards can be added continuously without exiting programming mode To add a card user (Method 2) This is the alternative way to enter using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card. cards To delete a card user by card number. Note users can be deleted continuously without exiting programming mode 1 ID number # ReadCard # 2 Read Card # .5. To delete a card user by user ID. This option can be used when a user has lost their card 2 User ID # To set a card and PIN user in card and PIN mode ( 3 1 # ) To Add a card and PIN user (The PIN is any 4-6 digits between 0000 & 999999 with the exception of 1234 which is reserved.) Add the card as for a card user Press * to exit from the programming mode Then allocate the card a PIN as follows: * Read card 1234 # PIN # PIN # To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselves To change a PIN in card and PIN mode (Method 2) Note that this is done outside programming mode so the user can undertake this themselves To delete a Card and PIN user just delete the card 2 User ID # To set a card user in card mode ( 3 0 # ) To Add and Delete a card user The operating is the same as adding and deleting a card user in 3 2 # To delete All users To delete ALL users. (Note that this is a dangerous option so use with care) 2 0000 # To unlock the door For a PIN user For a card User For a card and PIN user Enter the PIN then press # Read card Read card then enter PIN # 6.2. Relay Setting (Pulse mode, Toggle mode) Pulse mode (Factory default) Pulse mode - Door relay time setting 4 1~99 # The door relay time is between 1~99 seconds, the factory default setting is 5 seconds. Every time a valid tag/card or PIN is read/input in Pulse Mode, the relay will operate, for the pre-set relay pulse time * Read Card Old PIN # New PIN # New PIN # * ID number # Old PIN # New PIN # New PIN # .6. Toggle mode Toggle mode 4 0 # Every time a valid tag/card or PIN is read/input in Toggle Mode, the relay changes state, which will not turn back until read card or input PIN again. 6.3. Alarm Settings, Door Detecting Alarm output time To set the alarm output time (1~3 minutes) Factory default is 1 minute Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened by force, or if the door is opened after 120 seconds of the electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 1~3 minutes with the default being 1 minute. To disable door open detection (Factory default) To enable door open detection Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in succession either the keypad will lockout for 10 minutes or the alarm will operate, depending on the option selected below. Normal status: No keypad lockout or alarm (factory default) Keypad Lockout Alarm Output 5 1~3 # 6 0 # 6 1 # 7 0 # (Factory default setting) 7 1 # 7 2 # 7.To remove the alarm To reset the Door Forced Open warning To reset the Door Open Too Long warning Read valid card or Master Code # Close the door or Read valid card or Master Code # 9.Technical Specification Supply Voltage Current Consumption Door Relay Alarm output load Memory Codes Keypad Card Types Induction Distance Wiring Connections Tamper Protection Keypad Housing Operating Temperature Dimensions Weight 12V DC 20mA 3A 3A Non volatile EPROM memory 1000 Users 12 keys, 3 LED status indicators EM or EM compatible 2-6cm Electric lock Remote Request to Exit Door open detection External Alarm Negative loop, normally closed Metal L128 × 82 × 28mm L135 mm×W58 mm×H26 mm (K2) mm W mm H (BC-2000) 500g o o -40to 60(-40 F to 140 F) .7. BC-2000/K2 BC-2000/K2 1N4007 Φ6mm×27 mm Φ4mm×27 mm 10.Package Listing Name Digital Keypad User Manual Diode Wall Fixing Plug Self TapPINg Screws Qnty 1 1 1 4 4 Remark Used for fixing Used for fixing Model no. To reset to factory default, power off, press * , hold it and power on, release it until hear three beeps(two short, one long), means reset to factory default successfully. Remarks: Reset to factory default, the users information is still retained. 8.Resetting To Factory Default Setting 1 2 3 4 5 6 7 8 9 0 # K2 BC-2000 Access Control User manual Yellow Brown Grey Red Black Blue Purple Orange Exit button Door detectingswitch ALARM- OPEN D_IN DC /3A 12V BC2000/K2 - - + + Electric bolt - + POWER +12V GND NC COM NO NO NC COM NO +12V GND PUSH Special Power Supply COM NC Alarm Electric strike ALARM- OPEN D_IN BC2000/K2 - + Lock +12V GND NC COM NO In4007 Electric bolt NC Electric strike: NO : DC /3A 12V - + Common Power Supply Current200mA + - Yellow Brown Grey Red Black Blue Purple Orange Exit button Door detecting switch NO COM NC Alarm POWER NO NC COM GND 12V D_IN OPEN ALARM- K13 J3

Upload: paberge3458

Post on 17-Aug-2015

213 views

Category:

Documents


1 download

DESCRIPTION

BC-2000

TRANSCRIPT

1. Attach the rear plate to a single or double gang electrical box or secure to the wall firmly withat least three flat head screws.2. When wiring has been completed, attach the front cover to the rear plate. 3.Plug in the cable harness on the PCB (See Figure 3)4.attach the front cover(See Figure 4)Door Strike Relay NCDoor Strike Relay NO Door Strike Relay ComAlarmSwitched negative when activeTo Door EXIT Request Button Then Negati veTo Door Contact Then To Negative(+) 12VDC Positive Regulated Power Input (-) Negative Regulated Power Input .3.Do not plug the power supply or transformer into the mains until all wiring has been completed and the front cover secured.Contents2.Specifications3.Important Information1.Introduction 4.Mounting5.Wiring6.Detailed Programming Guide6.1 User Settings . 6.2. Relay Setting (Pulse mode, Toggle mode)6.3. Alarm Settings, Door Detecting7.To Remove The Alarm9.Technical Specification10.Package Listing8.Resetting To Factory Default Setting1112244566777Figure 1NCNOCOMRELAYFigure 2.1.1.Programmable FunctionsRelay momentary Relay strike timePulse mode,Toggle modeChange Codes 1 master, 1000 users 2.Programmable TimersDoor relay time 1-99 secondsAlarm time 1-3 minutes3.Pulse ModeToggle Mode4.Wiring ConnectionsElectric lockExternal bellExternal Push SwitchMagnetic ContactsAlarm5.12V DC Metal shell keypad12 keys with backlight 2.Specifications3.Important InformationIfholesaretobedrilledbeforemountingontoawall,checkforhiddencablesand/or pipes before drilling. Use safety goggles when drilling or hammering in cable clips.Every effort has been made to provide accurate information, however slight variations canoccur. We also reserve the right to make changes for product improvement at any timeNOTE: please read these instructions carefully before attempting to install the BC-2000/K2Internal Interface Circuit1. Alarm output interface (See Figure 1) 1.Introduction 2. Electric lock interface (See Figure 2)The BC-2000/K2 is a standalone access control, they use the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure.All programming is done through the keypad. Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure.The BC-2000/K2 can store 1000 users with card and 4-6 digits password codes.It has one relay output with 3 Amp changeover contacts.ALARM2KGNDR Q.2.4.Mounting Terminal Wire Connector Function321 NOCOMNC BluePurpleOrange87 6 5 4 OPEN D_IN12VALARMYellowBrownRedBlackGrey5.Wiring1.Unplug the cable harness and connect thenecessary cables(See Figure 3).2.Tape any wires that are unused.GNDFigure 4BC-2000Figure 31 23 45 67 89 0#K2After all wiring is completed and the unit face plate is attached to the back plate, power on, the red LED will be flashing.Power onBC-2000/K2 Quick Reference Programming GuideTo enter the programming modeTo exit from the programming modeNote that to undertake the following programming the master user must be logged inTo change the master code*Master code#9999 is the default factory master code * 0New code#New code#The master code can be 4-6 digits longTo add a PIN user1 User ID number # PIN # The ID number is any number between 000 ~ 999.The PIN is any 4-6 digits between 0000 ~ 999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming modeTo add a card user1 Read Card #Cards can be added continuously without exiting from programming modeTo delete a PIN or a card user. 2User ID number#for a PIN user or 2Read Card#for a card userUsers can be deleted continuously without exiting fromprogramming modeTo unlock the doorTo unlock the door for a PIN userTo unlock the door for a card userEnter the PIN then press #Present the card .4.6.Detailed Programming Guide6.1 User Settings . To enter the programming modeNote that to undertake the following programming the master user must be logged inTo change the master code *Master code# 9999 is the default factory master code 0New code#New code #The master code is any 4-6 digitsTo exit from the programming mode* Setting the working mode:Set valid card only usersSet valid card and PIN usersSet valid card or PIN users3 0 #by card only3 1 #by card and PIN together3 2 #by either card or PIN (default)To set a user in either card or PIN mode ( 32 # ) (Default setting)To add a PIN user1User ID number#PIN#The ID number is any number between 000-999. The PIN is any 4-6 digits between 0000-999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting from programming mode as follows:1User ID no 1 #PIN # User ID no 2 #PIN # To delete a PIN user2User ID number#Users can be deleted continuously without exiting programming modeTo change the PIN of a PIN user (This step must be done out of programming mode)*IDnumber # Old PIN#NewPIN#NewPIN#To add a card user (Method 1)This is the fastest way to enter cards using ID number auto generation.1 Read card #Cards can be added continuously without exiting programming modeTo add a card user (Method 2)This is the alternative way to enter using User IDAllocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card. cards To delete a card user by card number. Note users can be deleted continuously without exiting programming mode1 ID number # ReadCard # 2 Read Card#.5.To delete a card user by user ID. This option can be used when a user has lost their card2 User ID #To set a card and PIN user in card and PIN mode (3 1 # )To Add a card and PIN user(The PIN is any 4-6 digits between 0000 & 999999 with the exception of 1234 which is reserved.)Add the card as for a card user Press*to exit from the programming modeThen allocate the card a PIN as follows: *Read card1234 # PIN # PIN #To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselvesTo change a PIN in card and PIN mode (Method 2) Note that this is done outside programming mode so the user can undertake this themselvesTo delete a Card and PIN user just delete the card2 User ID #To set a card user in card mode (30# )To Add and Delete a card userThe operating is the same as adding and deleting a card user in3 2 #To delete All usersTo delete ALL users. (Note that this is a dangerous option so use with care) 2 0000 #To unlock the doorFor a PIN userFor a card UserFor a card and PIN userEnter the PINthen press #Read cardRead card then enter PIN #6.2. Relay Setting (Pulse mode, Toggle mode)Pulse mode (Factory default)Pulse mode - Door relay time setting4 1~99 #The door relay time is between 1~99 seconds, the factory default setting is 5 seconds.Every time a valid tag/card or PIN is read/input in Pulse Mode, the relay willoperate, for the pre-set relay pulse time*Read Card Old PIN#NewPIN#NewPIN#*IDnumber # Old PIN#NewPIN#NewPIN#.6.Toggle modeToggle mode4 0 #Every time a valid tag/card or PIN is read/input in Toggle Mode, the relay changes state, which will not turn back untilread card or input PIN again. 6.3. Alarm Settings, Door DetectingAlarm output timeTo set the alarm output time (1~3 minutes) Factory default is 1 minuteDoor Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically.Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if thedoor is opened by force, or if the door is opened after 120 seconds of the electro-mechanicallock not closed properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 1~3 minutes with the default being 1 minute.To disable door open detection(Factory default)To enable door open detectionKeypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in succession either the keypad will lockout for 10 minutes or the alarm willoperate, depending on the option selected below.Normal status: No keypad lockout or alarm (factory default)Keypad LockoutAlarm Output 5 1~3 # 6 0 # 6 1 # 7 0 # (Factory default setting) 7 1 # 7 2 #7.To remove the alarmTo reset the Door Forced Open warningTo reset the Door Open Too Long warningRead valid card or Master Code #Close the door orRead valid card or Master Code #9.Technical SpecificationSupply VoltageCurrent ConsumptionDoor RelayAlarm output loadMemoryCodesKeypadCard TypesInduction DistanceWiring ConnectionsTamper ProtectionKeypad HousingOperatingTemperatureDimensionsWeight12V DC20mA3A3ANon volatile EPROM memory1000 Users12 keys, 3 LED status indicatorsEM or EM compatible2-6cmElectric lockRemote Request to ExitDoor open detectionExternal AlarmNegative loop, normally closedMetalL128 82 28mm L135 mmW58 mmH26 mm (K2) mm Wmm H (BC-2000)500go o-40to 60(-40 F to 140 F).7.BC-2000/K2BC-2000/K21N40076mm27 mm4mm27 mm10.Package ListingNameDigital KeypadUser ManualDiodeWall Fixing PlugSelf TapPINg ScrewsQnty11144RemarkUsed for fixingUsed for fixingModel no.To reset to factory default, power off, press * , hold it and power on, release it until hear three beeps(two short, one long), means reset to factory default successfully. Remarks: Reset to factory default, the usersinformation is still retained.8.Resetting To Factory Default Setting1 23 45 67 890#K2 BC-2000Access ControlUser manualYellowBrownGreyRedBlackBluePurpleOrangeExit buttonDoor detecting switchALARM-OPEND_IN DC /3A 12VBC2000/K2- - + + Electric bolt -+POWER+12VGNDNCCOMNO NONC COM NO +12V GND PUSHSpecial Power SupplyCOMNCAlarmElectric strikeALARM-OPEND_INBC2000/K2-+Lock+12VGNDNCCOMNOIn4007Electric bolt NCElectric strike: NO :DC /3A 12V-+Common Power SupplyCurrent200mA+ -YellowBrownGreyRedBlackBluePurpleOrangeExit buttonDoor detecting switchNOCOMNCAlarmPOWERNO NCCOMGND12VD_INOPENALARM-K13J3