2-2_pfc_delta_pump072808_113402

4
Pr o Minent ® 21 1.6.2006 / P. 1 Chap. 1 Continuous or pulsating dosing Programmable suction and delivery stroke duration Pump can be adapted to the dosing media Integrated injection control optoGuard ® detects blocked dosing points, broken dosing lines and air or gas bubbles trapped in the dosing head Capacity range 12-80 l/h, 16-2 bar Stroke length infinitely adjustable from 0 - 100% (recommended range 30 - 100%) PVDF and stainless steel material versions Patented coarse/fine ventilation Detection and indication of diaphragm failure Adjustment and display of pump delivery from the keypad with choice of display in l/h or strokes/min Large backlit graphic display External control options via volt-free contacts with optional increase/reduce speed pulse Optional external control via standard 0/4-20 mA signal Interfaces for PROFIBUS ® or CANopen 14-day process timer option* for time and event-dependent dosing duties Connection for 2-stage level switch Power relay, for use especially in conjunction with the process timer to switch higher powers (230 V – 8 A) 3 LED displays for operation and warning and error message in plain text Optional concentration input for volume-proportional dosing * available from last quarter of 2006 1.4.a.1 Diaphragm Metering Pumps delta ® with Controlled Solenoid Drive 1.4.a Solenoid-drive Diaphragm Metering Pumps delta ® pk_1_131 optoDrive ® inside P r o M in e n t

Upload: mpica

Post on 18-Aug-2015

225 views

Category:

Documents


6 download

DESCRIPTION

bombas delta de prominent

TRANSCRIPT

ProMinent21 1.6.2006 / P. 1 Chap. 1 Continuous or pulsating dosing Programmable suction and delivery stroke duration Pump can be adapted to the dosing media Integrated injection control optoGuard detects blocked dosing points, broken dosinglines and air or gas bubbles trapped in the dosing head Capacity range 12-80 l/h, 16-2 bar Stroke length infinitely adjustable from 0 - 100% (recommended range 30 - 100%) PVDF and stainless steel material versions Patented coarse/fine ventilation Detection and indication of diaphragm failure Adjustment and display of pump delivery from the keypad with choice of display in l/hor strokes/min Large backlit graphic display External control options via volt-free contacts with optional increase/reduce speedpulse Optional external control via standard 0/4-20 mA signal Interfaces for PROFIBUS or CANopen 14-day process timer option* for time and event-dependent dosing duties Connection for 2-stage level switch Power relay, for use especially in conjunction with the process timer to switch higherpowers (230 V 8 A) 3 LED displays for operation and warning and error message in plain text Optional concentration input for volume-proportional dosing* available from last quarter of 20061. 4. a. 1 Di aphr agmMet er i ngPumpsdel t awi t hCont r ol l edSol enoi dDr i ve1. 4. a Sol enoi d- dr i veDi aphr agmMet er i ngPumpsdel t apk_1_131optoDriveinsideProMinentProMinent22 1.6.2006 / P. 1 Chap. 1Version Dosing head Suction/discharge connector Seals Ball valvesPVT PVDF PVDF PTFE CeramicSST Stainless steel Mat. No. 1.4404 Stainless steel Mat. No. 1.4404 PTFE CeramicPTFE-coated dosing diaphragmDosing repeatability 2% when used in accordance with the operating instructionsPermissible ambient temperature 10C to +45CAverage power consumption 78 WProtection IP65, insulation class FDelivery package: metering pump with mains cord (2m) and plug, connection kit for hose/pipe connectors as per table.1. 4. a Sol enoi d- dr i veDi aphr agmMet er i ngPumpsdel t aTechni cal Dat aMat er i al si nCont act wi t hChemi cal sPump type Pressure Capacity Stroke capacity Stroke frequency Connector size Suction lift* Shipping weightdeltabar l/h ml/stroke strokes/min mm m WG PVT/SST in kgDLTA 1612 16 12 1.0 200 8x5 6 10 / 11DLTA 1020 10 20 1.7 200 12x9 5 10 / 11DLTA 0730 7 30 2.5 200 12x9 5 10 / 11DLTA 0450 4 50 4.2 200 DN10 3 10 / 11DLTA 0280 2 80 6.7 200 DN10 2 10 / 11* suction lift with primed dosing head and suction lineProMinent23 1.6.2006 / P. 1 Chap. 11. 4. a Sol enoi d- dr i veDi aphr agmMet er i ngPumpsdel t a1. 4. a. 2 I dent codeOrder i ngSyst emBasi cTypeDLTA del t aser i esPump type1612 Capacity: 16 bar; 12 l/h1020 10 bar; 20 l/h0730 7 bar; 30 l/h0450 4 bar; 50 l/h0280 2 bar; 80 l/hDosing head materialSS Stainless steelPV PVDFSeals/diaphragm materialT PTFE/PTFE coatedS PTFE/diaphragm additionally with FPM coating for silica-laden mediaDosing head version0 Without ventilation, without valve spring1 Without ventilation, with valve spring2 With ventilation, without valve spring3 With ventilation, with valve springHydraulic connector0 Standard connectors as per technical data5 Discharge-side connector for 12/6 hose, suction-side standardVersion0 Without diaphragm failure indication1 Visual diaphragm failure indication2 Diaphragm failure indicationSupplyU Universal controller 100-240 VCord and plugA 2m EuropeB 2m SwitzerlandC 2m AustraliaD 2m USA / 115 V1 2 m without plugRelay0 Without relay1 1 alarm relay normally energised 1 x C/O contact 230 V 2 A3 3 alarm relay normally de-energised 1 x C/O contact 230 V 2 A4 as 1 + timing relay 2 x N.O. contacts 24 V 100 mA5 as 3 + timing relay 2 x N.O. contacts 24 V 100 mAA Shutdown and alarm relaynormally energised 2 x N.O. contacts 24 V 100 mAC as 1 + 4-20 mA output 1 x N.O. contact 24 V 100 mAG Power relay normally de-energised 1 x C/O contact 230 V 8 AAccessories0 Without accessories1 With foot valve and dosing valve,2 m suction line and 5 m discharge line2 as 0 + measuring beaker3 as 1 + measuring beakerControl variants0 Manual + external contact 1:1 +analogue 0/4-20 mA3 Manual + external contact with pulse control +analog 0/4-20 mA expansion4 as 0 + 14-day process timer5 as 3 + 14-day process timerC CANopenP As 3 + PROFIBUS interface, 9-way sub-DR As 3 + PROFIBUS interface, M12Access code0 Without access code1 With access codeLanguageDE GermanEN EnglishFR FrenchES SpanishPause/Level0 Pause N.C. contact level,N.C. contactDLTA 1612 SS T 0 0 0 U A 0 0 0 0 EN 0ProMinent24 1.6.2006 / P. 1 Chap. 11. 4. a Sol enoi d- dr i veDi aphr agmMet er i ngPumpsdel t a1. 4. a. 3 SparePar t sKi t s, Repl acement Di aphr agmsSpare parts kits for delta, consisting of:1 dosing diaphragm1 suction valve set1 discharge valve set2 ball valves1 set of seals1 connection kitStainless steel version without suction and discharge valve setsSpar epar t ski t sf or del t aOrder No.Type 1612 PVT 1027081SST 1027086Type 1020 PVT 1027082SST 1027087Type 0730 PVT 1027083SST 1027088Type 0450 PVT 1027084SST 1027089Type 0280 PVT 1027085SST 1027090Repl acement di aphr agmsf or del t aser i esType 1612 all materials 1000248Type 1020 all materials 1000249Type 0730 all materials 1000250Type 0450 all materials 1000251Type 0280 all materials 1025075pk_1_008