17/06/2010 UK Valencia RAL Petals and Staves Meeting
1
DC-DC for Stave Bus TapesRoy Wastie
Oxford University
17/06/2010 UK Valencia RAL Petals and Staves Meeting
2
Stave Overview
Carbon Fibre foam core plank
Module
Stave module controller
Cooling pipes
Size 1.2 m x 12cm 12 modules per side each with 2 hybrids
17/06/2010 UK Valencia RAL Petals and Staves Meeting
3
Stave Detail
Bus tape
Silicon Detector
ABCN chip
Hybrid flex PCB
17/06/2010 UK Valencia RAL Petals and Staves Meeting
4
Bus tape
Tape stack up
100μm track & gap
17/06/2010 UK Valencia RAL Petals and Staves Meeting
5
Stavelet
• Module evaluation
• Two types
• Segmented shield
• Solid shield
17/06/2010 UK Valencia RAL Petals and Staves Meeting
6
Layout Details
Serial Power Return
HV
Serial In
Power protection control
Wire bond pads
TTC busDataNTC
17/06/2010 UK Valencia RAL Petals and Staves Meeting
7
Openings for Bonding
150um
0.35mm & 0.65mm for HV pad
Kapton
Kapton
Kapton
Al
Copper pad
Adhesive
Wire bond
4 masks required one for Al screen, one for Copper tracks and two cover layers
17/06/2010 UK Valencia RAL Petals and Staves Meeting
8
Bus Cable Geometry and Impedance
11
1~10.7
1
2
CF
Cu
ADHESIVE
KAPTON
Materials: Al foil 2mil, Dupont LF0100, Shinetsu CA333 2 mils, Cu 18 um,Kapton 1 mil, Adhesive
Al
17/06/2010 UK Valencia RAL Petals and Staves Meeting
9
In house tape prototyping
• Thermal resistance– High conductivity glue layers
• Less material ie thinner Aluminium/kapton design– Aluminium 25μm on kapton 25μm for
screen layer and 50 μm Al for track layer– Hatched screen to reduce material– Easier to handle
• Rapid prototyping possible
17/06/2010 UK Valencia RAL Petals and Staves Meeting
10
Stave09 and DCDC Powering – moving forward
2.Integration of DCDC onto a Stavelet (shortened 4 module stave), what we presently have:
•Stavelet Bus cable is (presently) designed for serial powering •DCDC can be added, via the Power Protection Board drop-in connector, BUT is not ideal
•No DCDC power feed – it comes external to the Bus cable•Drop-in connector is multi-functional – used for other serial powering topologies (SPi, …)
•Not electrically optimised for DCDC•No ‘real estate’ available to integrate DCDC directly onto present Serial powered Stavelet
•The Power Protection Board is in the way!•No access to Stave cooling contact.
Propose designing a Stavelet Bus cable exclusively for DCDC
•Remove ALL serial powering trace routing from layout – freeing up space for DCDC requirements•Power feeds to converters and control could maybe integrated onto cable
•Revisit Bus cable shielding, currently 2 flavours exist:•Segmented – each module has it’s own individual shield (shields float w.r.t. each other)•Continuous – no segmentation (maximal coverage) with modules AC-coupled to shield•Optimise for DCDC…
BUT
•The geometry of the Stave will remain the same at 500mm x 120mm – fixed by tooling.•Availability of real estate for DCDC placement is still at a premium
Slide from Powering meeting CERN 30/3/10 Ashley Greenall
17/06/2010 UK Valencia RAL Petals and Staves Meeting
11
Stavelet Geometry – ‘real estate’ for DCDC
Available space per module for locating DCDC components(typically ~97.5mm x 6.2mm)
Slide from Powering meeting CERN 30/3/10 Ashley Greenall
17/06/2010 UK Valencia RAL Petals and Staves Meeting
12
Stavelet – Bus cables
•Bus cable routing is on a single layer – no crossovers of traces allowed (no vias used!)•Build is 18µm Cu with 50µm Kapton dielectric
•Expect majority of routing to stay as is e.g. Data I/O, HV distribution etc.•But Serial Power Return and associated control can be removed.
Data I/O (remains)
Serial Power Return (not needed)
HV (remains)
Available for DCDC (6.2mm wide)
•Bus cable shielding, 2 flavours exist:
Flexes are DC connected to their respective shield
Flexes are AC connected to the shield
Segmented Continuous
120
mm
• Insufficient Cu for DCDC power feed and return?• 6mm trace width of 18µm Cu: <6A• Need 2 traces for DCDC powering…• Consider selectively adding more Cu (35µm)
• Move DCDC powering off Bus cable to PCB?• If so, could we still use existing Bus cables?
Slide from Powering meeting CERN 30/3/10 Ashley Greenall
17/06/2010 UK Valencia RAL Petals and Staves Meeting
13
DCDC Powering Implementation for stavelet
Redesign CERN DCDC PCB to fit on to the stave bus tape connect with wire bonding. Limited to 6.2mm wide. Requires a narrow multilayer flex tape to bus the power in. DCDC PCB to tape and let it overhang, will need cooling ( add ceramic base board).
2mm side by side track single layer copper 105µm thickness
6.2mm
CERN DCDC PCB
17/06/2010 UK Valencia RAL Petals and Staves Meeting
14
CERN DC-DC convertor
DCDC PCB
Hybrid outline
Serial power track green
sensor outline
DCDC power track red
17/06/2010 UK Valencia RAL Petals and Staves Meeting
15
Full Stave DCDC• With 130nm, will the power system be able to tolerate power
dissipation and volt drop for 24 hybrid?• Too long for one DCDC narrow PCB, would require two.
(Flex/ridged) 105µm copper thicknessStavelet tape voltage drop & power