1655amu interconn 5.0
DESCRIPTION
Alcatel LucentTRANSCRIPT
Alcatel-Lucent 16551655 ACCESS MULTIPLEXER UNIVERSAL | RELEASE 1-5.0INTERCONNECT INFORMATION
A
AED8C939-20FEBRUARY 2008
ISSUE 6
This document provides application engineering details for 1655 Access Multiplexer Universal , and serves to supplement the Installation Manual. Specifications and application considerations are included to properly engineer the network element for desired functionality, as well as condition the location for proper operation and maintenance. The most current Issue of this drawing can be obtained in paper format or electronically downloaded from the Alcatel-Lucent Corporate Information Center (CIC) by specifying the drawing number.
The CIC website is accessed by non-Alcatel-Lucent employees at http://www.lucentdocs.com/cgi-bin/CIC_store.cgi. In addition, comments or questions concerning the document content should be directed through a Alcatel-Lucent Account Representative.
For Alcatel-Lucent employees, the CIC website is accessed at http://www.cic.lucent.com/. Comments or questions can be directed to a SME identified via: http://mvcde.mv.lucent.com/EAE/
Associated References365-312-818 Application and Planning Guide
365-312-822 User Operations Guide
365-374-821 Alarm and Trouble Clearing Guide
365-312-819 Installation Guide
365-312-820 Provisioning Guide
ED8C939-20 Interconnect Information
Reason for Re-issueIssue 1 07-30-2004 Original Issue
Issue 2 02-17-2004 Release 2.0
Issue 3 06-17-2004 Release 2.0.2
Issue 4 08-04-2006 Release 4.0
Issue 5 02-15-2007 Release 4.1 Added Trib Pack interconnect diagrams
Issue 6 02-29-2008 Release 5.0 E3/DS3_E14 interface
About This Drawing
ED8C939-20 ISSUE 6 A2
Description of Sheet Sheet Number
Updated This Issue
Title Sheet A1 *
About This Drawing A2
Reason for Re-issue A2 *
Table of Contents A3
Engineering Notes A4
Figure 1 - Subrack Power and Ground Wiring B1
Figure 2 - Station Clock Cable (100/120 Ohm) B2
Figure 3 - Station Clock (75 Ohm) B3
Figure 4 - Miscellaneous Discrete Cables (MDIO) B4
Figure 5- V11 Cables (EOW) B5
Figure 6- USB Cables B6
Figure 7- Q-LAN/G-LAN CABLES B7
Figure 8 - Craft Interface Terminal (CIT) CABLE B8
Figure 9 - Main Card SFP Module Cables B9
Figure 10 - P1-E1/63 Cables (120 Ohm) B10
Figure 11 - P1-E1/63 Cables (75 Ohm) B11
Figure 12 - E3/DS3_E14 Interface B12
Figure 13 - Lan Card (X8PL X41P-V2) Cable Interface B13
Figure 14 - DS1 Card (X16DS1) Cable Interface B14
Figure 15 - DS3 and E3 Card (X2E3-V2/X2DS3-V2) Cable interface B15
Figure 16 - EPL4_E132_75 Card (ASC106 and ASC107) Cable Interface B16
Figure 17 - EPL4_E14 Card (ASC105) Cable Interface B17
Figure 18 - ESW4_E14 Card (ASC108) Cable Interface B18
Figure 19 - S1-14/8 Card (ASC109) Cable Interface B19
Total Sheets 23
Table of Contents
ED8C939-20 ISSUE 6 A3
1. Graphics convention
Cable
Connection Furnished as Part of Component
Shield Connection
Coaxial Shield Connection
Division of General Wiring Views
Pair P
2. For Lucent engineered orders, job information shall be recorded by comcode number in the regional wiring lists.
3. For cable assemblies not identified in the ED8C939-10, use this guide and bulk cable to build site specific length cable.
4. When purchasing cable from other sources, specify Halogen free materials when available.
Engineering Notes
ED8C939-20 ISSUE 6 A4
Part of Metropolis AMU Shelf
(PWR A)(-48V A)PWR FEEDER
(PWR B)(-48V B)PWR FEEDER
Part of Main Card ASC101ASC110ASC114
Power Cable Assembies should be fabricated from Non-Halogen materials when available. Cable length and diameter must be calculated using aceptable voltage drop.
Use a minimum of 2.5mm guage wiremaximum 150 mm long
One of 4 threaded grounding points
ontop of 1m/2o or 2m/4o shelf
6 mm Ring Lug to Rack Ground
3mm Ring Lug
to 48 V Power supply or AC/DC Converter
to 48 V Power supply or AC/DC Converter
To Rack or other equipment Grounding Point
ED8C948-20 ISSUE 6 B1
Figure 1 - Subrack Power and Ground Wiring
B
ED8C948-20 ISSUE 6 B2
Figure 2 - Station Clock Cable (100/120 Ohm)
Part of Metropolis AMU Shelf
PART OFCA ASSY
Use prefabricated station clock cable or build from 100 Ohm or 120 Ohm STP cable. Specify lenght during site survey
To External Synchronization Suppply Unit (SSU)
BKYL
Sta
tion
Clo
ck O
utpu
t Pos
itive
P
Sta
tion
Clo
ck O
utpu
t Neg
ativ
e
P
Sta
tion
Clo
ck In
put P
ositi
ve
Sta
tion
Clo
ck In
put N
egat
ive
P
Gro
und
Gro
und
Part of Main Card ASC101ASC110ASC114
ED8C948-20 ISSUE 6 B3
Figure 3 - Station Clock (75 Ohm)
PART OFCA ASSY
Use prefabricated station clock cable or build from 2 lenghts of 75 Ohm Coax cable with copper braid and foil shield. Specify lenght during site survey
BKYLS
tatio
n C
lock
Out
put P
ositi
ve
Sta
tion
Clo
ck O
utpu
t Neg
ativ
e
Sta
tion
Clo
ck In
put N
egat
ive
Gro
und
Gro
und
Sta
tion
Clo
ck In
put N
egat
ive
Part of Metropolis AMU Shelf
To External Synchronization Suppply Unit (SSU)
Part of Main Card ASC101ASC110ASC114
ED8C948-20 ISSUE 6 B4
Figure 4 - Miscellaneous Discrete Cables (MDIO)
Out
put 4
retu
rn n
orm
ally
ope
n
PART OFCA ASSY
TO External Equipment
PPPPP
Out
put 4
retu
rn n
orm
ally
clo
sed
Out
put 3
retu
rn n
orm
ally
ope
n
Out
put 3
retu
rn n
orm
ally
clo
sed
Out
put 2
retu
rn n
orm
ally
ope
n
Out
put 2
retu
rn n
orm
ally
clo
sed
Out
put 1
retu
rn n
orm
ally
clo
sed
Out
put 1
retu
rn n
orm
ally
Ope
n
Inpu
t 4 re
turn
Inpu
t 3 re
turn
Inpu
t 2 re
turn
Inpu
t 1 re
turn
Out
put 4
rela
y co
ntac
t
Out
put 3
rela
y co
ntac
t
Out
put 2
rela
y co
ntac
t
Out
put 1
rela
y co
ntac
t
Inpu
t 4 in
put
Inpu
t 3 in
put
Inpu
t 2 in
put
Inpu
t 1 in
put
PPP
PP
Part of Metropolis AMU Shelf
Part of Main Card ASC101ASC110ASC114
ED8C948-20 ISSUE 6 B5
Figure 5- V11 Cables (EOW)
To External EOW Equipment
Use Prefabricated Cables orUse Shielded Twisted Pair (8 pair) for custom length cables
Rec
eive
64
kHz
Clo
ck fo
r Out
put P
os
Gro
und
PART OFCA ASSY
P
PP
P
PPP
Rec
eive
8 k
Hz
Fram
e S
ync
Out
put P
os
Rec
eive
64
kbps
Dat
a In
put P
os
Tran
smit
64 k
Hz
Clo
ck fo
r Out
put P
os
Tran
smit
8 kH
z Fr
ame
Sync
Out
put P
os
Tran
smit
64 k
bps
Dat
a In
put P
os
Not
Con
nect
ed
Rec
eive
64
kHz
Clo
ck fo
r Out
put N
eg
Rec
eive
8 k
Hz
Fram
e S
ync
Out
put N
eg
Rec
eive
64
kbps
Dat
a In
put N
eg
Gro
und
Tran
smit
64 k
Hz
Clo
ck fo
r Out
put N
eg
Tran
smit
8 kH
z Fr
ame
Sync
Out
put N
eg
Tran
smit
64 k
bps
Dat
a In
put N
eg
Part of Metropolis AMU Shelf
Part of Main Card ASC101ASC110
ED8C948-20 ISSUE 6 B6
Figure 6- USB Cables
To Customer Equipment or Fan Unit
Use prefabricated USB Cable (Not to exceed 15 Feet)
Part of Metropolis AMU Shelf
PART OFCA ASSY
Part of Main Card ASC101ASC110ASC114
ED8C948-20 ISSUE 6 B7
Figure 7- Q-LAN/G-LAN CABLES
REC
EIVE
DAT
A N
EG
TRA
NS
MIT
DA
TA N
EG
REC
EIVE
DAT
A PO
S
TRA
NS
MIT
DA
TA P
OS
PART OFCA ASSY
Use prefabricated LAN cable or build from standard CAT-5 cable
Part of Metropolis AMU Shelf
P
P
To Customer HUB or other LAN Interface
Part of Main Card ASC101ASC110asc 114
ED8C948-20 ISSUE 6 B8
Figure 8 - Craft Interface Terminal (CIT) CABLE
To CIT
Tran
smitt
ed D
ata
Part of Metropolis AMU Shelf
Use prefabricated CIT cable From ED8C939-10 or build from standard CAT-5 cable (4 Pair STP) with overall jacket
Gro
und
PART OFCA ASSY
P
P
Cle
ar to
Sen
d
Rec
eive
d D
ata
Req
uest
to s
end
Dat
a Te
rmin
al R
eady
Part of Main Card ASC101ASC110ASC114
Figure 9 - Main Card SFP Module Cables
ED8C948-20 ISSUE 6 B9
TO E
xter
nal E
quip
men
t
OUT 1
IN 1IN
OUT
LC
Part of Main Card ASC114
STM
4/16
SFP
1
Part of Metropolis AMU Shelf
TO E
xter
nal E
quip
men
t
IN 1
OUT 1
IN 2
OUT 2
STM-4/16 slots 1 and 2STM-4 ModulesSTM-1/4 Bidirectional (See Note 2)STM-4/16 CWDM ModulesSTM-16 Modules
SFP OPTIONS (ASC110 and ASC114)
OUT
IN
OUT
IN
2
SFP
SFP
1
Part of Metropolis AMU Shelf
LC
Part of Main Card ASC101
OUT
IN3
SFP
OUT
IN4
SFP
STM
1/4S
TM 1
IN 2
OUT 2
OUT 1
IN 1
LC
LC
LC
Note 1 :When Using STM-1E Module, use ITT Cannon 75 Ohm 1.0/2.3 RF Plugs and Mini-Coax Cable with overall Braid.
Note 2: Bidirectional SFP's require only one fiber for both IN and OUT.
STM-1/4 slots 3 and 4STM-1 ModulesSTM-4 ModulesSTM-1E (See Note 1)STM-1/4 Bidirectional (See Note 2)STM-4/16 CWDM Modules
OUT 1
TO E
xter
nal E
quip
men
t
OUT 2
IN 2
OUT 2
IN 1
IN 2
OUT 1
IN 1IN
IN
IN
IN
OUT
OUT
OUT
OUT
LC
LC
LC
LC
STM
1/4
SFP
4
Part of Main Card ASC110
STM
4/16
SFP
SFP
3
2
SFP
1
Part of Metropolis AMU Shelf
STM-1 slots 3 and 4STM-1 ModulesSTM-1E (See Note 1)STM-1/4 Bidirectional (See Note 2)
STM-1/4 slots 1 and 2STM-1 ModulesSTM-4 ModulesSTM-1E (See Note 1)STM-1/4 Bidirectional (See Note 2)STM-4/16 CWDM Modules
SFP OPTIONS (ASC101)
ED8C948-20 ISSUE 6 B10
Figure 10 - P1-E1/63 Cables (120 Ohm)
To DDF
Part of Metropolis AMU Shelf
Part of Option CardP1-E1/63ASC102
Use Cat 5 STP/FTP 4 Pair
TRA
NS
MIT
PO
S 1
TRA
NS
MIT
NE
G 1
PART OFCA ASSY
P
P
TRA
NS
MIT
NE
G 2
TRA
NS
MIT
PO
S 2
RE
CE
IVE
NE
G 1
RE
CE
IVE
PO
S 1
RE
CE
IVE
NE
G 2
RE
CE
IVE
PO
S 2
P
P
ED8C948-20 ISSUE 6 B11
Figure 11 - P1-E1/63 Cables (75 Ohm)
Part of Metropolis AMU Shelf
Part of Option CardP1-E1/63ASC104
Use 8X COAX with overall Shield
TRA
NS
MIT
1
PART OFCA ASSY
RE
CE
IVE
1
RE
CE
IVE
2
TRA
NS
MIT
2
To DDF
TRA
NS
MIT
3
RE
CE
IVE
3
RE
CE
IVE
4
TRA
NS
MIT
4
ED8C948-20 ISSUE 6 B12
Figure 12 - E3/DS3_E14 Interface
E1
Por
ts 1
-4(2
cab
les)
IN5
OUT
For Custom Lengths use 4.1 mm coax cable
TO D
DF
Part of E3/DS3_E14
Card
Part of Metropolis AMU
OUT
IN6
OUT
IN7
P PPPRECEIVE POS 1
TRANSMIT POS 2
TRANSMIT NEG 2
TRANSMIT NEG 1
TRANSMIT POS 1
RECEIVE POS 2
RECEIVE NEG 2
RECEIVE NEG 1
To D
DF
PA
RT
OF
CA
AS
SY
E3/
DS3
ED8C948-20 ISSUE 6 B13
Figure 13 - Lan Card (X8PL X41P-V2) Cable Interface
Part of AdapterCard
Part of X8PLCard
Use Cat 5 STP/FTP 2 or 4 Pair
To DDF
Part of Metropolis AMU Shelf
REC
EIVE
DAT
A N
EG
TRA
NS
MIT
DA
TA P
OS
REC
EIVE
DAT
A PO
S
TRA
NS
MIT
DAT
A N
EG
PART OFCA ASSY
P
P
Part of X41P-V2Card
Part of AdapterCard
PART OFCA ASSY
TRA
NS
MIT
DA
TA P
OS
REC
EIVE
DAT
A PO
S
TRA
NS
MIT
DAT
A N
EG
REC
EIVE
DAT
A N
EG
P
P
To DDF
ED8C948-20 ISSUE 6 B14
Figure 14 - DS1 Card (X16DS1) Cable Interface
REC
EIVE
NEG
TRA
NS
MIT
PO
S
TRA
NS
MIT
NEG
REC
EIVE
PO
S
Part of Metropolis AMU
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16
P
P
Use Shielded Twisted Pair Cable (100 Ohm)
PART OFCA ASSY
To DDF
Part of AdapterCard
Part of X16DS1Card
ED8C948-20 ISSUE 6 B15
Figure 15 - DS3 and E3 Card (X2E3-V2/X2DS3-V2) Cable interface
INTP2.1
OUT
For Custom Lengths use 4.1 mm coax cable
TO D
DF
Part of Adapter Card
Part of X2DS3 or
X2E3 Card
Part of Metropolis AMU
OUT
INTP2.2
ED8C948-20 ISSUE 6 B16
Figure 16 - EPL4_E132_75 Card (ASC106 and ASC107) Cable Interface
Use 8X COAX with overall Shield for 75 Ohm applications
Part of Metropolis AMU Shelf
Part of Option CardEPL4_E132_75ASC107
Use Cat 5 STP/FTP 4 Pair for 120 Ohm Applications
PART OFCA ASSY
P
P
REC
EIVE
NEG
1
REC
EIVE
NEG
2
REC
EIVE
PO
S 2
TRA
NS
MIT
PO
S 1
TRA
NS
MIT
NEG
1
TRA
NS
MIT
NEG
2
TRA
NS
MIT
PO
S 2
REC
EIVE
PO
S 1
120 Ohm Option
PART OFCA ASSY
P
P
To DDF
REC
EIVE
DAT
A N
EG
REC
EIVE
1
TRA
NS
MIT
1
REC
EIVE
2
TRA
NS
MIT
2
TRA
NS
MIT
3
75 Ohm Option
REC
EIVE
4
REC
EIVE
3
TRA
NS
MIT
4
REC
EIVE
DAT
A PO
S
TRA
NS
MIT
DA
TA P
OS
TRA
NS
MIT
DA
TA N
EG
P
P
To DDF
To DDF
NOT CONNECTED
PART OFCA ASSY
Use Cat 5 STP/FTP 2 or 4 Pair
ED8C948-20 ISSUE 6 B17
Figure 17 - EPL4_E14 Card (ASC105) Cable Interface
To DDF
Use Cat 5 STP/FTP 2 or 4 Pair
PART OFCA ASSY
TRA
NS
MIT
DA
TA N
EG
TRA
NS
MIT
DA
TA P
OS
P
P
REC
EIVE
DAT
A PO
S
REC
EIVE
DAT
A N
EG
TO E
xter
nal E
quip
men
t
OUT 2
IN 2
OUT 1
IN 1IN
OUT
IN
OUT
LC
LCG
E
SFP
10
SFP
7
SFP OPTIONS
Gigabit Ethernet SXGigabit Ethernet LXGigabit Ethernet ZXSingle Fiber Gigabit Ethernet UpstreamSIngle Fiber Gigabit Ethernet Downstream
Note: Use Multi-mode fiber when using Gigabit Ethernet SX modules. All others use Single Mode fiber. 45 degree angle rotating boot LC connectors are required for SFP jumper connections
NOT CONNECTED
PART OFCA ASSY
P
P
P
P
REC
EIVE
PO
S 1
TRA
NS
MIT
PO
S 2
TRA
NS
MIT
NEG
2
TRA
NS
MIT
NEG
1
TRA
NS
MIT
PO
S 1
REC
EIVE
PO
S 2
REC
EIVE
NEG
2
REC
EIVE
NEG
1
To DDF
Use Cat 5 STP/FTP 4 Pair for 120 Ohm Applications
120 Ohm Option
75 Ohm Option
Part of Metropolis AMU Shelf
Part of Option CardEPL4_E14ASC105
Use 8X COAX with overall Shield for 75 Ohm applications
PART OFCA ASSY
REC
EIVE
2
REC
EIVE
1
TRA
NS
MIT
1
TRA
NS
MIT
2
To DDF
REC
EIVE
3
TRA
NS
MIT
3
REC
EIVE
4
TRA
NS
MIT
4
ED8C948-20 ISSUE 6 B18
Figure 18 - ESW4_E14 Card (ASC108) Cable Interface
75 Ohm Option
To DDF
TO E
xter
nal E
quip
men
t
OUT 1
OUT 2
IN 2
IN 1
Part of Metropolis AMU Shelf
OUT
OUT
LC
Part of Option CardESW4_E14ASC108
LC IN
IN
SFP
GE
10
7
SFP
Use Cat 5 STP/FTP 4 Pair for 120 Ohm Applications
TRA
NS
MIT
PO
S 1
PART OFCA ASSY
P
P
P
P Use 8X COAX with overall Shield for 75 Ohm applications
PART OFCA ASSY
REC
EIVE
NEG
1
REC
EIVE
NEG
2
REC
EIVE
PO
S 2
TRA
NS
MIT
NEG
1
TRA
NS
MIT
NEG
2
TRA
NS
MIT
PO
S 2
REC
EIVE
PO
S 1
120 Ohm Option
TRA
NS
MIT
2
TRA
NS
MIT
1
REC
EIVE
1
REC
EIVE
2
To DDF
Gigabit Ethernet SXGigabit Ethernet LXGigabit Ethernet ZXSingle Fiber Gigabit Ethernet UpstreamSIngle Fiber Gigabit Ethernet DownstreamFast Ethernet 100Base LX
SFP OPTIONS
NOT CONNECTED
Use Cat 5 STP/FTP 2 or 4 Pair
TRA
NS
MIT
4
REC
EIVE
4
TRA
NS
MIT
3
REC
EIVE
3
REC
EIVE
DAT
A N
EG
REC
EIVE
DAT
A PO
S
TRA
NS
MIT
DA
TA P
OS
TRA
NS
MIT
DA
TA N
EG
P
P
To DDF
PART OFCA ASSY
ED8C948-20 ISSUE 6 B19
Figure 19 - S1-14/8 Card (ASC109) Cable Interface
SFP
SFP
SFP
SFP
SFP
SFP
SFP
SFPTO
DD
F
SINGLE MODE
OUT 8
IN 8
IN 6
OUT 7
IN 7
OUT 6
OUT 5
IN 5
OUT
IN
IN
OUT
OUT
IN
OUT
IN
IN 4
OUT 4
IN 3
OUT 3
IN 2
OUT 2
OUT 1
LC CABLE ASSEMBLY
IN 1OUT
IN
OUT
IN
OUT
OUT
IN
IN
8
6
7
5
4
3
2
1
Part of Metropolis AMU Shelf
Part of Option CardSI-14/8 ASC109
STM-1/4 slots 1 and 5STM-1 ModulesSTM-4 ModulesSTM-1E ModulesSTM-1/4 Bidirectional STM-4/16 CWDM Modules
SFP OPTIONS
STM-1 slots 2,3,4,6,7,and 8STM-1/4 BidirectionalSTM-1 ModulesSTM-1E Modules
Note 1 :When Using STM-1E Module, use ITT Cannon 75 Ohm 1.0/2.3 RF Plugs and Mini-Coax Cable with overall Braid.
Note 2: Bidirectional SFP's require only one fiber for both IN and OUT.
STM-1/4
STM-1/4
STM-1
STM-1
STM-1
STM-1
STM-1
STM-1