1.5 3 d-box 6 d-box

2
PERFORMANCE UNDER MAXIMUM LOAD 250I / 250HD 400I / 400HD MAXIMUM LIFTING CAPACITY 250 lb / 114 kg 400 lb / 182 kg HORIZONTAL LOAD Translation on limited friction surfaces can be done on weights up to 3 times vertical lifting capacity. MAXIMUM STROKE 1.5 inch / 38.1 mm MAXIMUM VELOCITY 100 mm/s MAXIMUM ACCELERATION +/- 1 g-force FREQUENCY RANGE 0-100 Hz OPERATING TEMPERATURE RANGE 0-40 °C OPERATING HUMIDITY 10 to 50 % The next generation of D-BOX actuators is here. Benefit from a more robust and compact actuator form factor while retaining the same core architecture and software integration process that lifted D-BOX ahead of its competitors. The new generation comes in a more robust packaging, containing a quick start guide that outlines the key components as well as all the configuration steps needed to ensure the simplest of setup. 3 6 1 .5 POWER REQUIREMENTS AVERAGE POWER To be used for electric consumption (Watts) AVERAGE POWER To be used for converter specification (VA) PEAK CURRENT To be used for breaker specification (A) 250 lb 1 TO 2 ACTUATORS 105 W 283 VA 3.2 A 3 TO 4 ACTUATORS 210 W 566 VA 6.5 A 400 lb 1 TO 2 ACTUATORS 136 W 371 VA 4.6 A 3 TO 4 ACTUATORS 272 W 742 VA 9.2 A 250 lb 1 TO 2 ACTUATORS 127 W 302 VA 2.2 A 3 TO 4 ACTUATORS 254 W 604 VA 4.5 A 400 lb 1 TO 2 ACTUATORS 163 W 393 VA 2.0 A 3 TO 4 ACTUATORS 326 W 786 VA 4.1 A 120 V 50/60 HZ 230 V 50/60 HZ 190-986-0050-EN1 February 2020

Upload: others

Post on 30-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1.5 3 D-BOX 6 D-BOX

PERFORMANCE UNDER MAXIMUM LOAD 250I / 250HD 400I / 400HD

MAXIMUM LIFTING CAPACITY 250 lb / 114 kg 400 lb / 182 kg

HORIZONTAL LOAD Translation on limited friction surfaces can be doneon weights up to 3 times vertical lifting capacity.

MAXIMUM STROKE 1.5 inch / 38.1 mm

MAXIMUM VELOCITY 100 mm/s

MAXIMUM ACCELERATION +/- 1 g-force

FREQUENCY RANGE 0-100 Hz

OPERATING TEMPERATURE RANGE 0-40 °C

OPERATING HUMIDITY 10 to 50 %

The next generation of D-BOX actuators is here. Benefit from a more robust and compact actuator form factor while retaining the same core architecture and software integration process that lifted D-BOX ahead of its competitors. The new generation comes in a more robust packaging, containing a quick start guide that outlines the key components as well as all the configuration steps needed to ensure the simplest of setup.

3”

6”

1.5”

POWER REQUIREMENTS

AVERAGE POWERTo be used for

electric consumption(Watts)

AVERAGE POWERTo be used for converter

specification(VA)

PEAK CURRENTTo be used for breaker

specification(A)

250 lb1 TO 2 ACTUATORS 105 W 283 VA 3.2 A

3 TO 4 ACTUATORS 210 W 566 VA 6.5 A

400 lb1 TO 2 ACTUATORS 136 W 371 VA 4.6 A

3 TO 4 ACTUATORS 272 W 742 VA 9.2 A

250 lb1 TO 2 ACTUATORS 127 W 302 VA 2.2 A

3 TO 4 ACTUATORS 254 W 604 VA 4.5 A

400 lb1 TO 2 ACTUATORS 163 W 393 VA 2.0 A

3 TO 4 ACTUATORS 326 W 786 VA 4.1 A

120

V 5

0/60

HZ

230

V

50/6

0 H

Z

190-986-0050-EN1 February 2020

Page 2: 1.5 3 D-BOX 6 D-BOX

SYSTEM OVERVIEW*

250 I 250 HD*400 I

BRACKET OPTIONS

ENDING OPTIONS

* HD refers to an actuator designed with a double nut ball screw for higher durability in high strain environment and extended periods of time.

*Two actuator system

2.7 in69 mm

17.4

in44

1 mm

2.7 in

69 mm

2.7 in

69 mm

10.6

in26

9 mm

2.3 in58 mm 2.3 in

58 mm

2.3 in

57 mm

15.8

in40

2 mm

2.7 in69 mm 2.7 in

69 mm

2.7 in

69 mm

12.1

in30

8 mm

2.3 in58 mm 2.3 in

58 mm

2.3 in

57 mm

10.6 in269 mm

15.8 in402 mm

12.1 in308 mm

17.4 in441 mm

2.3 in57 mm

2.3 in58 mm

2.3 in58 mm

27 in69 mm

27 in69 mm

2.7 in69 mm

2.3 in57 mm

2.3 in58 mm

2.3 in58 mm

2.7 in69 mm

2.7 in69 mm

2.7 in69 mm

1.5” ACTUATOR FAMILY400 HD*

NON CAPTIVEENDINGS

L BracketAvailable onI series only

U BracketAvailable onI series only

H BracketAvailable on

HD series only

CAPTIVEENDINGS

9.5 in241 mm

3.0 in

76 mm

8.8 in

222 mm

3.0 in76 mm

8.8 in222 mm

9.5 in241 mm