15 - 1038 sez 5 ver eng rev d14 sez_ 5_ver...pws inverter short circuit iub / iux inverter...
TRANSCRIPT
![Page 1: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/1.jpg)
Section 5
![Page 2: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/2.jpg)
page n.1
Section 5
1 GENERATOR DESCRIPTION 3
1.0 Rack overview . . . . . . . .
1.1 M.C.U. Master Control Unit .
1.2 Line and Safety Supervisor .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
.
.
.
.
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
.
.
.
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.3 Filament Inverter Driver .
1.4 Normal Speed Starter . .
1.5 General Terminal Board .
. .
. .
. .
1.6 Inverter and Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.7a Main switches for NS .
1.7b Main switches for HS 1.8 H.V. Transformer.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Rev L15 SERIES R306.3x
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
![Page 3: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/3.jpg)
page n.2
SERIES R306.3x Rev L15
![Page 4: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/4.jpg)
1 GENERATOR DESCRIPTION page n.3
1 GENERATOR DESCRIPTION
1.0 Rack overview
Front, back and lateral view
Inverter
H.V. transformer
Safety Supervisor
Main switches
Filament Inverter Driver
M.C.U.
N.S. Starter
G.T.B.
Line Filter
Rev L15 SERIES R306.3x
![Page 5: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/5.jpg)
page n.4 1 GENERATOR DESCRIPTION
1.1 M.C.U. Master Control Unit
This is the main computer. Here are coming all signals that make the generator working; from the different PCB signals are coming here via 20 pins flat cables, control consolle is lied by a DB9 connector, the PC is
connectable by a DB9 cable. On this board we have a Flash memory with the software inside and a
backup-Ram that stores all configuration, tube calibration and anatomic programs.
SERIES R306.3x Rev L15
SIGNAL DESCRIPTION
IRP (digital input) Potter Reply (from G.T.B.)
IPR (digital input) Preparation Radiography (from G.T.B.)
ISR (digital input) Start Radiography (from G.T.B.)
IFS (digital input) Start Fluoroscopy (from G.T.B.)
IST-1 (digital input) Safety Tube 1 (from G.T.B.)
ITS (digital input) Tomo Slow (from G.T.B.)
ITF (digital input) Tomo Fast (from G.T.B.)
ITA (digital input) Tomo 8 Degree (from G.T.B.)
ITB (digital input) Tomo 20 Degree (from G.T.B.)
ITC (digital input) Tomo 30 Degree (from G.T.B.)
ITD (digital input) Tomo 40 Degree (from G.T.B.)
IPE (digital input) X-Ray Stop (from G.T.B.)
![Page 6: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/6.jpg)
1 GENERATOR DESCRIPTION page n.5
Rev L15 SERIES R306.3x
SIGNAL DESCRIPTION
INS (digital input) Safety Rotation Normal Speed (from Starter N.S.)
IHS (digital input) Safety Rotation High Speed (from Starter N.S.-H.S.)
IRM (digital input) High Voltage Present at 75% of kV (from M.C.U.)
IPW (digital input) DC Bar Charged (from M.C.U.)
IUB (digital input) Unbalanced Power Bridge Inverter (from M.C.U.)
iec- (analog input) Negative Analog Continuous Fluoro (from G.T.B.)
iec+ (analog input) Positive Analog Continuous Fluoro (from G.T.B.)
icl (analog input) Fluoro Current 5V=10mA (from M.C.U.)
icm (analog input) Radiography Medium Current 5V=150mA (from M.C.U.)
ich (analog input) Radiography High Current 5V=1500mA (from M.C.U.)
irsf (analog input) Small Focus Current Real Value 5V=10A (from Filament Inv. Drv.)
irlf (analog input) Larege Focus Real Value 5V=10A (from Filament Inv. Drv.)
OCC (digital output) 80% of Tube Maximum kHUT
OBS-1 (digital output) Bucky Start Working Station 1
OBS-2 (digital output) Bucky Start Working Station 2
OBS-3 (digital output) Bucky Start Working Station 3
OHS (digital output) High Speed Rotation (to Starter N.S.-H.S.)
ORP (digital output) Radiography Preparation
ORT (digital output) Radiography Time During Exposure
OFT (digital output) Fluoroscopy Time During Exposure
OXT (digital output) Pulsed Fluoroscopy Time During Exposure
OHT (digital output) Start High Voltage Active
OREI (digital output) Reset Allarm
OAB (digital output) Turn Off Generator from M.C.U.
OBF (digital output) Filament Current Safety
COM (digital output) Commun ON-OFF Generator
OFF (digital output) OFF Generator
ON (digital output) On Generator
ORR (digital output) Start Rotation Normal Speed
OFR (digital output) Anode Fluoroscopy Rotation
OAT (digital output) Anode Rotation Time
olf (analog output) Reference Large Focus Current 5V=10A
osf (analog output) Reference Small Focus Current 5V=10A
okv (analog output) Reference High Voltage 5V=200kV
![Page 7: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/7.jpg)
page n.6 1 GENERATOR DESCRIPTION
1.2 Line and Safety Supervisor
The uController on this board checks all signal considered usefull for generator working. Here comes the
+24Vdc used to supply the different generator board.
SERIES R306.3x Rev L15
SIGNAL DESCRIPTION
ORS Radiography Time
OFT Fluoroscopy Time During Exposure
OAB Turn OFF Generator from M.C.U.
OBF Filament Current Safety Through M.C.U.
COM ON / OFF Common from Control Console Through M.C.U.
ON ON Key from Control Console Through M.C.U.
OFF OFF Key from Control Console Through M.C.U.
![Page 8: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/8.jpg)
1 GENERATOR DESCRIPTION page n.7
1.3 Filament Inverter Driver
This is the filament supplier, could lit filament till 8 Amps.
The real filament heating value is measured by the MCU uProcessor, and shown on the PC if NAVIGATOR is connected.
Rev L15 SERIES R306.3x
SIGNAL DESCRIPTION
orsf Reference Small Focus Current 5V=10A
orlf Reference Large Focus Current 5V=10A
+irsf Positive Small Focus Current Real Value 5V=10A
+irlf Positive Larege Focus Real Value 5V=10A
IST-1 Safety Tube 1
OBF Filament Current Safety
OSF Filament Shut Down
OLF Filament selection
![Page 9: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/9.jpg)
page n.8 1 GENERATOR DESCRIPTION
1.4 Normal Speed Starter
This is the normal speed starter so, 3000 RPM. By wire jumper you can set the capacitance value for different kind of tubes.
SERIES R306.3x Rev L15
SIGNAL DESCRIPTION
264Vac Power Supply from Service Transformer
0Vac Power Supply from Service Transformer
IND Inductive
CAP Capacitive
COM Common
INS Safety Rotation Normal Speed
OAT Anode Rotation Time
![Page 10: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/10.jpg)
1 GENERATOR DESCRIPTION page n.9
1.5 General Terminal Board
This board job is the interface of the generator with the external devices, such as potter or accessories.
Rev L15 SERIES R306.3x
SIGNAL DESCRIPTION
101-102-103 +24Vdc
104-105-106-112-119-117 115-128-126-124-122-130
0Vdc
107 iec+
108 iec-
113 ITA Tomo 8 Degree
111 IS2
110 IS3
109 IST-1Safety Tube 1
120 IPE x-ray safety
118 IFS Start Fluoroscopy
116 ITS Tomo Slow
114 Preparation Radiography
![Page 11: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/11.jpg)
pagina n.10 1 GENERATOR DESCRIPTION
SERIES R306.3x Rev L15
127 Start Radiography
125 Potter Reply
123 Door Safety
121 ITF Tomo Fast
132 ITB Tomo 20 Degree
131 ITC Tomo 30 Degree
129 ITD Tomo 40 Degree
135 OCC 80% of Tube Maximum kHUT /OS1
137 OXT pulse fluoro exp. Time / OS3
138 OFT Fluoroscopy Exposure Time / OS2
139 ORT Radiography Exposure Time
201-202 204-205
JP1 selection OXT pulse fluoro exp. Time ORP Radiography Preparation
206-207 209-210
JP2 Selection OBS-1 Bucky Start Working Station 1 OBS-2 Bucky Start Working Station 2 OBS-3 Bucky Start Working Station 3
211-212 214-215
JP3 Selection OBS-1 Bucky Start Working Station 1 OBS-2 Bucky Start Working Station 2 OBS-3 Bucky Start Working Station 3
216-217 219-220
JP4 Selection OBS-1 Bucky Start Working Station 1 OBS-2 Bucky Start Working Station 2 OBS-3 Bucky Start Working Station 3
221-222 224-225
JP18 Selection ORM 75% high voltage value OXT pulse fluoro exp. Time ORT Radiography Exposure Time
226-229 227-230
IRP Potter Reply
![Page 12: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/12.jpg)
1 GENERATOR DESCRIPTION page n.11
1.6 Inverter and Driver
That’s the power inverter
Rev L15 SERIES R306.3x
SIGNAL DESCRIPTION
Vrail+ / Vrail- DC-rail charged
cbr+ H.V. Transformer primary current
cbr- H.V. Transformer primary current
PWS Inverter short circuit
IUB / IUX Inverter unballanced bridge
OREI Reset inverter
GF 1-4 Gate triggering signal IGBT 1-3
GF 2-3 Gate triggering signal IGBT 2-4
![Page 13: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/13.jpg)
page n.12 1 GENERATOR DESCRIPTION
1.7a Main switches for NS
Main switches
SERIES R306.3x Rev L15
COMPONENT DESCRIPTION
AC - DC Power Supply 24Vdc 500W
Si1 Magneto-thermal switch 3P C 63 A
Si2 Magneto-thermal switch 3P C 6 A
Si3 Magneto-thermal switch 2P C 3 A
LA Contactor line
COMPONENT
AC - DC
Si1
Si2
Si3
LA Contactor line
Magneto-thermal switch 2P C 3 A
Magneto-thermal switch 3P C 6 A
Magneto-thermal switch 3P C 63 A
Power Supply DRT-240-24 IN 400-500 OUT 24V 10A
![Page 14: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/14.jpg)
page n.13 1 GENERATOR DESCRIPTION
1.7b Main switches for HS
Main switches
SERIES R306.3x Rev L15
COMPONENT DESCRIPTION
AC - DC Power Supply 24Vdc 500W
Si1 Magneto-thermal switch 3P C 63 A
Si2 Magneto-thermal switch 3P C 6 A
LA Contactor line
![Page 15: 15 - 1038 SEZ 5 ver ENG rev D14 SEZ_ 5_ver...PWS Inverter short circuit IUB / IUX Inverter unballanced bridge OREI Reset inverter GF 1-4 Gate triggering signal IGBT 1-3 GF 2-3 Gate](https://reader035.vdocuments.mx/reader035/viewer/2022070913/5fb4ac552b667b5e293173b4/html5/thumbnails/15.jpg)
1 GENERATOR DESCRIPTION page n.14
1.8 H.V. Transformer
H.V. Transformer
Rev L15 SERIES R306.3x
SIGNAL DESCRIPTION
1 Main inverter supply
2 Main inverter supply
lfa Filament Supply 1 Large
+24Vdc Common Fliament Supply
lfb Filament 2 Large
sfa Filament Supply 1 Small
+24Vdc Common Filament Supply
sfb Filament Supply 2 Small
STP H.V. Transformer connected
kV+ kV+ Real to MCU
kV- kV- Real to MCU
ihv+ High Voltage Current + Real to MCU
ihv- High Voltage Current - Real to MCU