141482
TRANSCRIPT
-
7/21/2019 141482
1/6
Specifications and Ordering InformationPart Number 141482-01
Rev. D (11/08)
Page 1 of 6
170172 FieldMonitor Internal 7200 ProximitorModuleBently Nevada Asset Condition Monitoring
DescriptionThe 170172 Internal 7200 Proximitor Module is a dual Proximitor module that willwork with any standard 7200 series 5mm or 8mm probe in 5m and 9m systemlengths. This modules dual internal Proximitor sensors eliminate the need forexternal Proximitor sensors, and allow direct connection of up to two proximityprobes and their associated extension cables.
-
7/21/2019 141482
2/6
Specifications and Ordering InformationPart Number 141482-01
Rev. D (11/08)
Page 2 of 6
Specifications
Unless otherwise noted, the following specificationsare for a proximity transducer system at +22C(+72F) with a -24 Vdc power supply, a 10 kload, aGE supplied AISI 4140 steel target and a probegapped at 1.27 mm (50 mils). Typical is defined as
90% of the devices built meeting the specification.The calibration range is 250 m (10 mil)to 2250 m(90 mil), (Approximately 1 to 17 Volt dc).
Incremental
Scale Factor:
7.87 mV/m (200 mV/mil)
6.5% includinginterchangeability error whenmeasured in increments of 0.25mm (10 mils) over the linearrange.
Deviation from
best fit straightline (DSL):
Less than 38 m (1.5 mil)deviation from best fit straightline.
Minimum
Target Size:
15.2 mm (0.6 inch) diameter (flattarget).
Shaft Diameter:Minimum: 50.8 mm (2 inches).
Recommended
minimum:
76.2 mm (3 inches). With XYprobes in the same plane, shaftdiameters smaller than 50.8 mm(2 inches) will experienceelectrical noise due to crosstalk.
Proximitor Sensor
Weight:
353 g (12.7 oz)
StorageTemperature:
-40C to +85C (-40F to +185F)
Operating
Temperature:
-35C to +85C (-30F to +185F)
RelativeHumidity:
100% condensing non-submerged from +7C to +85C(+45F to +185F) when
connectors are protected.Intrinsic safety:
The 1701 Proximitor Sensor isdesigned to be used only with the1701 Internal Galvanic Isolator.
Hazardous Area Approvals
-00 ApprovalsOrdering Option
North America
Ex nA IIC T4
Class I, Zone 2
Class I, Div 2
Groups A, B, C, D
T4 @ -30C = Ta = +70C
per dwg 139255
Certification
Number
CSA 1166985
European/ATEX
II 3G EEx nA [L] IIC T4
LCIE 00ATEX6016X
T4 @ -30C = Ta = +70C
Brazil
Br-Ex nA [nL] IIC T4
MC, AEX-8304-X
T4 @ -30C = Ta = +70C
-05 ApprovalsOrdering Option
North America
Ex nA [ia] IIC T4
Class I, Zone 2(0)
Class I, Div 2
-
7/21/2019 141482
3/6
Specifications and Ordering InformationPart Number 141482-01
Rev. D (11/08)
Page 3 of 6
Groups A, B, C, D
T4 @ -30C = Ta = +70C
per dwg 141265
Certification
Number
CSA 1166985European/ATEX
II 1/3 G EEx nA[ia] ia IIC T4
LCIE 00ATEX6017X
T4 @ -30C = Ta = +70C
Probe
Probe dcresistance(nominal)
(RPROBE):
3.3 +0.79 /m (0.24 /ft).
Connector
torquerequirement:
0.565 Nm (5 inlb.) minimum(approximately 1/8 turn pastfinger tight)
Minimum Cable
Bend Radius:
25.4 mm (1.0 in)
ProbeTemperature
Range:
-35C to +177C (-31F to +351F)
Relative
Humidity:
95% non-condensing non-submerged from +2C to +100C(+35F to +212F) whenconnectors are protected.
Extension Cable
Cable dc
resistance,nominal:
Center
conductor
(RCORE):
0.74 /m (0.23 /ft)
Shield (RJACKET):
0.06 /m (0.02 /ft)
Capacitance:
59.5 pF/m (15.4 pF/ft)
Temperature
Range:-51C to +177C (-60F to +351F)
Ordering Information
Internal 7200 Series Proximitor Module
170172-XXX-XX
A: Proximitor Type0 5 0 7200 Internal Dual 5-metre
Proximitor Sensor0 9 0 7200 Internal Dual 9-metre
Proximitor Sensor
B: Hazardous Area ApprovalUse the 05option in the 1701/06 Isolator Terminal Base
0 0 Division 2/Zone 20 5 Division 2/Zone 2 for Monitor
Division 1, Zone 0/1 forTransducers
Note: For 7200 5 mm and 8 mm proximity probesand their associated extension cables, contact yoursales professional.
-
7/21/2019 141482
4/6
Specifications and Ordering InformationPart Number 141482-01
Rev. D (11/08)
Page 4 of 6
Dimensional Drawing
Dimensions are in millimetres (inches)
126.9 (5.00)
(0.85)
(4.15)
105.3
21.6
-
7/21/2019 141482
5/6
Specifications and Ordering InformationPart Number 141482-01
Rev. D (11/08)
Page 5 of 6
Performance Graphs
170172 Internal 7200 Proximitor Module
Figure 1: 5-metre Proximitor and 4-metre (13.1 feet) cable at high temperature
-20%
-15%
-10%
-5%
0%
5%
10%
15%
20%
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
ISFERROR
Referencedto20
0MV/MIL
-10
-5
0
5
10
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
DSLERROR
IN
MILS
Referencedto20
0MV/MIL
-24.000
-22.000
-20.000
-18.000
-16.000
-14.000
-12.000
-10.000
-8.000
-6.000
-4.000
-2.000
0.000
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
OUTPUT(VOLTS)
25 deg C (77 deg F) 70 deg C (158 deg F) 85 deg C (185 deg F)
-
7/21/2019 141482
6/6
Specifications and Ordering InformationPart Number 141482-01
Rev. D (11/08)
Page 6 of 6
Figure 2: 5-metre Proximitor and 4-metre (13.1 feet) cable at low temperature
Bently Nevada and Proximitor are trademarks of General Electric Company.
Copyright 2000. Bently Nevada LLC.1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 775.782.3611 Fax: 775.215.2873www.ge-energy.com/bently
All rights reserved.
-20%
-15%
-10%
-5%
0%
5%
10%
15%
20%
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
ISFERROR
Referencedto200MV/MIL
-10
-5
0
5
10
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
DSL
ERROR
IN
MILS
Referencedto200MV/MIL
-24.000
-22.000
-20.000
-18.000
-16.000
-14.000
-12.000
-10.000
-8.000
-6.000
-4.000
-2.000
0.000
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
OUTPUT(VOLTS)
25 deg C (77 deg F) -20 deg C (-4 deg F) -35 deg C (-31 deg F)