STRUCTURAL SHEET LIST
S001 - GENERAL NOTES
S002 - GENERAL NOTES & TYPICAL DETAILS
S003 - TYPICAL DETAILS
S004 - TYPICAL DETAILS
S005 - TYPICAL DETAILS
S006 - TYPICAL DETAILS
S007 - TYPICAL DETAILS
S101 - CROFT FRAMING PLANS
S102 - ELEVATOR FRAMING PLANS
S103 - LIBRARY FRAMING PLANS
S104 - LIBRARY FRAMING PLANS
S105 - ROOM 259 PLAN & ROOM 171A PLAN
S106 - TOWER AHU PLANS
S201 - WEST HALL - SECTIONS
S202 - ELEVATOR - SECTIONS
S203 - ELEVATOR - SECTIONS
S204 - ELEVATOR - SECTIONS
S205 - LIBRARY - SECTIONS
S206 - LIBRARY - SECTIONS
S207 - CROFT - SECTIONS
S208 - CROFT - SECTIONS
010000 GENERAL
1. CONFORM TO THE REQUIREMENTS OF THE ONTARIO BUILDING CODE 2012, AND ANY APPLICABLE ACTS OF AUTHORITY HAVING JURISDICTION.
2. READ STRUCTURAL DRAWINGS IN CONJUNCTION WITH THE SPECIFICATIONS AND ALL OTHER CONTRACT DOCUMENTS.
3. BEFORE PROCEEDING WITH WORK, CHECK ALL THE DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH THE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND REPORT DISCREPANCIES TO THE CONSULTANT. DO NOT SCALE THE DRAWINGS.
4. REFER TO THE ARCHITECTURAL AND OTHER DRAWINGS FOR LOCATIONS AND DIMENSIONING OF OPENINGS AND SLEEVES NOT SHOWN ON THE STRUCTURAL DRAWINGS. HOWEVER, OBTAIN THE CONSULTANT'S PRIOR APPROVAL BEFORE INSTALLING OPENINGS, SLEEVES, ETC. WHICH ARE NOT SHOWN ON STRUCTURAL DRAWINGS.
5. SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATIONS OF PITS, BASES, SUMPS, TRENCHES, DEPRESSIONS, GROOVES, CURBS, CHAMFERS AND SLOPES NOT SHOWN ON STRUCTURAL DRAWINGS.
6. HORIZONTAL AND VERTICAL DESIGN LOADS ARE NOTED. THEY SHALL NOT BE EXCEEDED DURING CONSTRUCTION.
7. TYPICAL STRUCTURAL DETAILS SHALL GOVERN THE WORK. IF DETAILS DIFFER ON THE DRAWINGS, THE MOST STRINGENT SHALL GOVERN.
8. ALL TEMPORARY WORKS INCLUDING SHORING ARE TO BE PROVIDED BY THE CONTRACTOR.
9. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS.
010001 DESIGN NOTES
1. THE BUILDING IS DESIGNATED AS BELONGING TO THE HIGH IMPORTANCE CATEGORY, AS DEFINED IN THE OBC 2012.
2. ALL REINFORCED CONCRETE ELEMENTS HAVE BEEN DESIGNED IN ACCORDANCE WITH CSA STANDARD A23.3.
3. ALL STRUCTURAL STEEL ELEMENTS HAVE BEEN DESIGNED IN ACCORDANCE WITH CAN/CSA-S16.
4. ALL STRUCTURAL MASONRY ELEMENTS HAVE BEEN DESIGNED IN ACCORDANCE WITH CSA STANDARD S304.1.
5. LATERAL FORCES ON STRUCTURAL FRAME
a. THE LATERAL FORCES ARE RESISTED BY THE EXISTING MASONRY LOAD-BEARING AND MASONRY SHEAR WALLS IN RENOVATED AREAS AND THE NEW MASONRY ELEVATOR CORE IN THE NEW ELEVATOR CONSTRUCTION AREAS.
b. WIND:
i) THE DESIGN OF THE STRUCTURE FOR WIND IS BASED ON AN HOURLY WIND PRESSURE OF 0.44 kPa (BASED ON 1/50 YEAR RETURN).
ii) EXPOSURE CONDITION: ROUGH TERRAIN
iii) THE IMPORTANCE FACTOR, Iw, FOR WIND DESIGN IS 1.15. FOR DEFLECTION ANALYSIS, THE FACTOR IS 0.75.
iv) THE DESIGN WIND FORCES HAVE BEEN CALCULATED IN ACCORDANCE WITH THE ONTARIO BUILDING CODE 2012 AND WITH THE SIMPLE PROCEDURE DESCRIBED IN THE USER'S GUIDE - NBC 2010 - STRUCTURAL COMMENTARIES (PART 4).
c. EARTHQUAKE:
i) THE DESIGN OF THE STRUCTURE FOR EARTHQUAKE IS BASED ON:
Ie = 1.30
SITE CLASS = C
Sa(0.2) = 0.22
Sa(0.5) = 0.13
Sa(1.0) = 0.067
Sa(2.0) = 0.021
PGA = 0.12
Rd = 1.0 (EXISTING AREAS), 1.5 (NEW MASONRY ELEVATOR WALLS)
Ro = 1.0 (EXISTING AREAS), 1.5 (NEW MASONRY ELEVATOR WALLS)
Fa= 1.0
Fv= 1.0
Mv = 1.0
ii) THE SEISMIC HAZARD INDEX FOR THIS SITE IS:
IeFaSa(0.2)=0.286
iii) THE DESIGN EARTHQUAKE FORCES HAVE BEEN CALCULATED IN ACCORDANCE WITH THE ONTARIO BUILDING CODE 2012.
iv) THE BUILDING’S STRUCTURAL CONFIGURATION IS DESIGNATED AS REGULAR.
6. LATERAL FORCES ON FOUNDATION WALLS
a. WALLS RETAINING EARTH ARE DESIGNED TO SAFELY WITHSTAND A HORIZONTAL PRESSURE AT ANY DEPTH (h) GIVEN BY THE EXPRESSION:
P = K ( h + q) , WHERE K IS THE LATERAL EARTH PRESSURE COEFFICIENT P IS THE PRESSURE EXERTED HORIZONTALLY h IS THE DEPTH BELOW GRADE
IS THE UNIT WEIGHT OF SOIL q IS THE SURCHARGE ON THE GROUND SURFACE
b. FOUNDATION AND OTHER WALLS RETAINING EARTH HAVE BEEN DESIGNED FOR SURCHARGE OF 12 kPa
c. THE WALLS HAVE BEEN DESIGNED ASSUMING THAT THERE IS FREE-DRAINING BACKFILL, OR THAT OTHER PROVISIONS HAVE BEEN MADE, SUCH THAT THE WALLS ARE NOT SUBJECT TO HYDROSTATIC PRESSURE.
7. SNOW LOADS ON ROOFS
a. THE ROOFS HAVE BEEN DESIGNED WITH Ss = 0.9 kPa AND Sr = 0.4 kPa.
b. THE IMPORTANCE FACTOR, IS, IS 1.15 FOR ULS AND 0.9 FOR SLS.
c. ADDITIONAL SNOW ACCUMULATIONS ADJACENT TO HIGHER WALLS, ROOFS AND MECHANICAL UNITS ARE INDICATED ON THE DRAWINGS.
8. RAINWATER LOADS ON ROOFS
a. THE ROOFS HAVE BEEN DESIGNED FOR NO FLOW CONTROL DRAINAGE.
9. WIND UPLIFT OF ROOFS
a. ALL ROOF ELEMENTS INCLUDING JOISTS, METAL DECK, AND THEIR CONNECTIONS TO THE STRUCTURE ARE TO BE DESIGNED FOR UPWARD SUCTION DUE TO WIND. THE NET UPWARD DESIGN PRESSURES ARE NOTED ON THE RELEVANT PLANS.
10. LIVE AND OTHER LOADS
a. SEE NOTES BELOW FLOOR PLANS.
b. IN THE DESIGN OF COLUMNS, WALLS, BEAMS, FLAT SLABS ETC. THE INDICATED LIVE LOADS HAVE BEEN REDUCED AS PER TRIBUTARY AREA CONSIDERATIONS OF THE ONTARIO BUILDING CODE.
c. STRUCTURE SUPPORTING CURTAINWALL HAS BEEN DESIGNED FOR A MAXIMUM VERTICAL LIVE LOAD DEFLECTION OF 19 mm
11. FUTURE EXTENSIONS
a. THE STRUCTURE HAS NOT BEEN DESIGNED FOR ANY FUTURE EXTENSIONS.
020000 EXISTING CONDITIONS
1. THE DRAWINGS GOVERNING ALTERATIONS TO EXISTING STRUCTURAL WORK WERE PREPARED USING THE FOLLOWING ASSUMPTIONS:
a. THE WORKMANSHIP AND MATERIALS EMPLOYED ON THE EXISTING BUILDINGS WERE OF GOOD QUALITY AND THE BUILDING HAS NOT DETERIORATED SIGNIFICANTLY.
b. BEARING WALLS, STRUCTURAL STEEL, STRUCTURAL CONCRETE AND TIMBER FRAMING IS REASONABLY TRUE AND PLUMB.
2. EXISTING STRUCTURAL INFORMATION USED IN PREPARING THESE DOCUMENTS WERE TAKEN FROM THE FOLLOWING DOCUMENTS. REFER TO NOTE BELOW REGARDING VERIFICATION OF THE EXISTING INFORMATION.
a. CROFT CHAPTER HOUSE - “UNIVERSITY OF TORONTO UNIVERSITY COLLEGE” STRUCTURAL DRAWINGS S1-S5 (5 SHEETS TOTAL), PREPARED BY ERIC R. ARTHUR, WILSON NEWTON ROBERTS ASSOCIATE ARCHITECTS, DATED JAN 14, 1972.
b. CENTRAL TOWER AND WEST HALL – “UNIVERSITY OF TORONTO UNIVERSITY COLLEGE PHASE II” STRUCTURAL DRAWINGS S1-S5 (5 SHEETS TOTAL), PREPARED BY C.D. CARRUTHERS & WALLACE CONSULTANTS LIMITED, DATED MAY 31, 1974.
c. EAST HALL AND LIBRARY – “UNIVERSITY OF TORONTO UNIVERSITY COLLEGE PHASE III” STRUCTURAL DRAWINGS S1-S5 (5 SHEETS TOTAL), PREPARED BY C.D. CARRUTHERS & WALLACE CONSULTANTS LIMITED, DATED 15 SEP, 1976.
3. BEFORE PROCEEDING WITH ALTERATIONS TO STRUCTURAL MEMBERS, VERIFY THAT THE ASSUMPTIONS ON THE DRAWINGS ARE CORRECT. SHOULD THE ASSUMPTIONS NOT BE CORRECT, NOTIFY THE CONSULTANT IMMEDIATELY. THE CONSULTANT WILL DETERMINE REVISIONS NECESSARY TO THE WORK AS SHOWN. THE CONTRACTOR SHALL PROVIDE THE NECESSARY ASSISTANCE TO ENABLE THE CONSULTANT TO DETERMINE THE EXTENT OF THE REVISIONS NECESSARY.
4. INVESTIGATE THE EXISTING BUILDING TO DETERMINE ACTUAL FIELD CONDITIONS, TAKE FIELD DIMENSIONS AND PERFORM OTHER INSPECTION NECESSARY TO CARRY OUT DESIGN OF SHORING, BRACING AND THE LIKE, TO SCHEDULE THE SEQUENCE OF OPERATIONS, AND PREPARE SHOP DRAWINGS AND DETAILS.
5. DETERMINE THE NEED FOR, PROVIDE AND DESIGN SHORING, BRACING, NEEDLING, SCAFFOLDING, AND THE LIKE, IN ACCORDANCE WITH THE REQUIREMENTS OF THE ONTARIO BUILDING CODE, SO THAT LOADS APPLIED TO THEM WILL BE SAFELY CARRIED. SUPERIMPOSED LIVE LOADS, CONSTRUCTION LOADS AND WIND LOADS SHALL BE TAKEN INTO ACCOUNT AND THE LATERAL STABILITY OF THE ELEMENTS SUPPORTED AND THE SHORING AND NEEDLING SHALL BE INSURED.
6. PREPARE DESIGN OF SHORING, AND THE LIKE, IN CO-OPERATION WITH OTHER TRADES SO THAT NEW WORK MAY BE INSTALLED AS REQUIRED.
030000 CONCRETE
1. MATERIALS
a. CONCRETE
i) CONFORM TO THE REQUIREMENTS OF CSA STANDARD A23.1 (LATEST VERSION) AND THE FOLLOWING FOR STRENGTH, SLUMP, WATER-TO-CEMENTING MATERIALS CONTENT AND AIR CONTENT.
ii) NOMINAL MAXIMUM SIZE OF AGGREGATE SHALL BE 20 mm. USE SMALLER AGGREGATES AS APPROPRIATE IN AREAS OF CONGESTED REINFORCING STEEL OR TO IMPROVE WORKABILITY. MODIFY MIX DESIGNS TO SUIT.
CATEGORY DESCRIPTION
EX
PO
SU
RE
CL
AS
S
PE
R A
23.1
CO
NC
RE
TE
S
TR
EN
GTH
f'c
(M
Pa)
MA
X. W
/C
RA
TIO
AIR
C
ON
TE
NT
1 SCOPE
CM 1 FOUNDATION MIX
25 5%-8%
FOOTINGS AND CAPS
CM 2 SLAB ON GRADE MIX
25 INTERIOR SLABS ON GRADE
CM 3 COLUMN AND WALL MIX
30 CONCRETE COLUMNS AND WALLS NOT EXPOSED TO FREEZE THAW OR DE-ICING CHEMICALS
CM 4 TOPPING MIX 20 TOPPINGS ON CONCRETE.
CM 5 COMPOSITE DECK MIX
25 SLABS ON METAL DECK
CM 6 PAVING MIX C-2 32 0.45 5%-8%
EXTERIOR PAVING AND SIDEWALKS
CM 7 EXTERIOR WALL MIX
F-2 25 0.55 4%-7%
FOUNDATION WALLS AND OTHER WALLS EXPOSED TO FREEZE THAW BUT NOT EXPOSED TO DE-ICING CHEMICALS
CM 8 LEAN MIX 0.4 max.3
4-6% (EXTERIOR ONLY)
UNSHRINKABLE FILL
1. WHERE AGGREGATES SMALLER THAN 14 mm ARE USED, INCREASE AIR CONTENT BY 1%
2. REINFORCED CONCRETE EXPOSED TO DE-ICING CHEMICALS TO HAVE DCI CORROSION INHIBITOR @ 11L/cu.m. DOSAGE OR APPROVED EQUIVALENT
3. MAX. 25kg CEMENT/cu.m.
b. REINFORCEMENT:
i) CONFORM TO THE REQUIREMENTS OF CSA STANDARD G30 SERIES.
ii) REINFORCING BARS SHALL HAVE A MINIMUM YIELD STRENGTH fy = 400 MPa, AND WELDED WIRE FABRIC SHALL HAVE A MINIMUM YIELD STRENGTH OF fy = 386 MPa, SUPPLY IN FLAT SHEETS.
iii) WHERE WELDING OF REBAR IS INDICATED, WELDABLE GRADE REBAR SHALL BE USED.
2. EXECUTION
a. SLAB ON GRADE
i) PLACE SLABS ON GRADE ON MATERIAL CAPABLE OF SUSTAINING 24 kPa WITHOUT SETTLEMENT RELATIVE TO THE BUILDING FOOTINGS.
ii) BEFORE PLACING SLAB, PLACE 200 mm OF 20 mm MAXIMUM SIZE CLEAR CRUSHED STONE OVER THE SUB GRADE. THOROUGHLY ROLL AND CONSOLIDATE TO THE LINES AND LEVELS REQUIRED.
b. CONCRETE AND REINFORCEMENT
i) PROVIDE DOWELS TO WALLS AND COLUMNS SIMILAR IN NUMBER, SIZE, AND SPACING TO THE VERTICAL STEEL IN THE WALL OR COLUMN EXCEPT WHEN NOTED OTHERWISE.
ii) CONSTRUCTION JOINTS:
HORIZONTAL CONSTRUCTION JOINTS SHALL NOT BE MADE IN BEAMS OR JOISTS, UNLESS SHOWN OR REVIEWED BY THE CONSULTANT.
VERTICAL CONSTRUCTION JOINS MAY BE MADE ONLY AT MID-SPAN OF BEAMS, JOISTS, AND SLABS UNLESS OTHERWISE SHOWN OR DIRECTED AND THEIR LOCATION SHALL BE REVIEWED BY THE CONSULTANT.
PROVIDE 38x89 KEYS AT CONSTRUCTION JOINTS UNLESS NOTED OTHERWISE.
iii) NO SLEEVES TO BE PLACED VERTICALLY OR HORIZONTALLY THROUGH BEAMS WITHOUT BEING REVIEWED BY THE CONSULTANT.
iv) NO OPENINGS SHALL BE MADE IN FLAT SLAB COLUMN STRIPS UNLESS SHOWN OR REVIEWED BY THE CONSULTANT.
v) WELDING OF REBAR SHALL BE DONE IN ACCORDANCE WITH CSA W186.
c. CONCRETE COVER TO REINFORCEMENT:
i) CONFORM TO THE REQUIREMENTS OF CSA STANDARD A23.1 (LATEST VERSION) AND THE FOLLOWING FOR COVER TO REINFORCEMENT (mm):
NOT EXPOSED (N) AND FOR FIRE RATING:
LOCATION OR MEMBER FIRE RATING (HOURS)
UP TO 1 1.5 2 3 4
BEAMS AND GIRDERS
(PRINCIPAL REINFORCEMENT) 35M AND SMALLER
40 40 40 40 50
SLABS – 25M AND SMALLER 25 25 25 35 40
30M 30 30 30 35 40
35M 35 35 35 35 40
COLUMNS (VERTICAL BARS) – 35M AND SMALLER
40 40 50 50 63
WALLS – 25M AND SMALLER 25 40 50 50 63
30M 30 40 50 50 63
35M 35 40 50 50 63
STIRRUPS AND TIES 30
i) ADDITIONAL COVER REQUIREMENTS AS APPLICABLE:
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:
i. 35M BARS AND SMALLER: 75mm
ii. 45M BARS AND LARGER: 2x THE NOMINAL BAR DIAMETER
CONCRETE EXPOSED TO CHLORIDES (C-1, C-3) (DOES NOT INCLUDE CONCRETE PROTECTED BY A WATERPROOFING MEMBRANE):
i. 30M BARS AND SMALLER: 60mm
ii. 35M BARS AND LARGER: 2x THE NOMINAL BAR DIAMETER
EXPOSED TO EARTH OR WEATHER (F-1, F-2)
i. 25M AND SMALLER: 40mm
ii. 30M BARS AND LARGER: 1.5x THE NOMINAL BAR DIAMETER
d. REINFORCING IN SLAB ON DECK
i) WELDED WIRE MESH REINFORCING IS TO BE CHAIRED AND SECURELY POSITIONED IN THE MIDDLE OF THE COVER SLAB OF ALL SLABS ON COMPOSITE STEEL DECK UNLESS OTHERWISE NOTED ON THE DRAWINGS.
e. ARCHITECTURAL CONCRETE
i) DESIGNATE CONCRETE AS ARCHITECTURALLY EXPOSED IN ACCORDANCE WITH THE FOLLOWING TABLE. REFER TO THE SPECIFICATION FOR SPECIFIC REQUIREMENTS FOR ARCHITECTURAL CONCRETE (AEC).
CATEGORY DESCRIPTION SCOPE
AEC 0 STANDARD CONCRETE ALL CONCRETE NOT DESIGNATED AS AEC BELOW.
AEC 1 BASIC ELEMENTS CONCRETE EXPOSED TO VIEW IN THE FINISHED BUILDING, BUT NOT IN GENERAL PUBLIC USE SUCH AS IN SIDE MECHANICAL ROOMS AND STAIRS USED EXCLUSIVELY FOR EMERGENCY EXITING INCLUDING.
AEC 2 PUBLIC ELEMENTS CONCRETE EXPOSED TO VIEW IN SPACES FREQUENTED BY THE PUBLIC BUT GENERALLY IN TRANSITION SUCH AS CORRIDORS OR FIELD HOUSE ACCESS STAIRS INCLUDING
AEC 3 IMPORTANT PUBLIC ELEMENTS SPACES THAT WILL BE OCCUPIED BY THE PUBLIC FOR SIGNIFICANT PERIODS OF TIME, BUT NOT CONSIDERED SHOWCASE SPACES SUCH AS LOBBIES AND MEZZANINES AROUND THE FIELD HOUSE INCLUDING
AEC 4 SHOWCASE ELEMENTS CONCRETE EXPOSED TO VIEW IN THE MOST IMPORTANT PUBLIC SPACES LIKE THE MAIN BUILDING LOBBY AND ENTRANCE LOBBY TO THE FIELD HOUSE INCLUDING:
f. WATERSTOPS
i) PROVIDE WATERSTOPS AT ALL CONCRETE JOINTS MORE THAN 600 MM BELOW GRADE.
040000 MASONRY
1. MATERIALS
a. ALL MASONRY UNITS SHALL COMPLY WITH THE REQUIREMENTS OF CSA STANDARD A371-04, MINIMUM NET AREA COMPRESSIVE STRENGTH, 15 MPa.
b. GROUT FILL - MINIMUM 28-DAY COMPRESSIVE STRENGTH, 10 MPA AND A 200-250 MM SLUMP.
c. MORTAR - CONFORM TO THE REQUIREMENTS OF CSA STANDARD A179-04, TYPE S.
2. EXECUTION
a. WHERE REINFORCING BARS, DOWELS, ANCHOR BOLTS, ETC. ARE SHOWN EMBEDDED IN MASONRY, BUILD THESE TIGHT INTO MASONRY VOIDS WITH GROUT FILL.
b. BENEATH STEEL AND CONCRETE BEAMS AND COLUMNS, PROVIDE A MINIMUM DEPTH OF 400 mm OF 100% SOLID MASONRY UNITS OR HOLLOW MASONRY UNITS FILLED SOLID, PROJECTING A MINIMUM OF 200 mm BEYOND THE EDGES OF BEARING PLATES, EXCEPT AS NOTED OTHERWISE.
c. BENEATH SLABS, METAL OR TIMBER DECK, AND STEEL OR TIMBER JOISTS, PROVIDE A MINIMUM DEPTH OF 200 mm OF 100% SOLID MASONRY UNITS OR HOLLOW MASONRY UNITS FILLED SOLID.
d. BENEATH STEEL, CONCRETE OR REINFORCED MASONRY LINTELS PROVIDE A MINIMUM LENGTH OF 200 mm AND A MINIMUM DEPTH OF 200 mm OF 100% SOLID MASONRY UNITS OR HOLLOW MASONRY UNITS FILLED SOLID.
e. BUILD MASONRY TIGHT INTO WEBS OF ALL WALL BEARING STEEL BEAMS AT THEIR POINTS OF BEARING.
f. BUILD MASONRY TIGHT INTO WEBS OF ALL STEEL COLUMNS.
g. WHERE 100% SOLID MASONRY UNITS ARE NOTED, THE MASONRY SHALL BE SET WITH FULLY FILLED JOINTS USING TYPE S MORTAR AS DEFINED IN CSA STANDARD A179-04.
h. PROVIDE CONTROL JOINTS IN MASONRY WALLS AS SHOWN IN TYPICAL DETAIL 0409.
i. LINTELS
i. PROVIDE LINTELS OVER ALL OPENINGS OR RECESSES IN MASONRY WALLS, INCLUDING THOSE FOR MECHANICAL OR ELECTRICAL SERVICE OR EQUIPMENT. SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS.
ii. SEE TYPICAL DETAIL 0402 FOR LINTEL SIZES AND DETAILS UNLESS NOTED OTHERWISE.
iii. FIRE PROTECT LINTELS ABOVE OPENINGS MORE THAN 2m IN LOADBEARING WALLS AND MORE THAN 3m WIDE IN NON-LOADBEARING WALLS AS PER DIRECTION FROM THE ARCHITECT.
j. SUPPORT OF VENEER
i. MASONRY VENEER, WHERE PRESENT AND WHERE NOT SUPPORTED BY THE FOUNDATION, SHALL BE SUPPORTED AT EACH FLOOR, STARTING AT THE SECOND FLOOR (U/N) BY A
2017-12-22
ABBREVIATIONS 0001A. BOLT
ADJALT
ARCH
ASL
=
==
=
=
ANCHOR BOLT
ADJUSTABLEALTERNATE
ARCHITECTURAL
ADDITIONAL SNOW LOAD
B
BEWBLL
BUL
BLDGBM
BPL
BSMT
=
==
==
=
==
BOTTOM
BOTTOM EACH WAY
BOTTOM LOWER LAYER
BOTTOM UPPER LAYER
BUILDING
BEAM
BASE OR BEARING PLATE
BASEMENT
@ = AT
c/c, o/c
C/W
C
Cf
CANT
CA
CB
COL
CONC
CONSTR
CJ
CONT
==
==
==
==
=
==
=
CENTRE TO CENTRE
COMPLETE WITH
EPOXY COATED
FACTORED COMPRESSIVE
FORCE, kN
CANTILEVER
COLUMN ABOVE
COLUMN BELOW
COLUMN
CONCRETE
CONSTRUCTION
CONSTRUCTION JOINT
CONTINUOUS
DET
DIAG
DIA, Ø
DIM
DJ
DO
DL
DWG(S)
DWL(S)
==
=
=
==
=
==
DETAIL
DIAGONAL
DIAMETER, BAR
DIAMETER
DIMENSION
DOUBLE JOIST
DITTO
DEAD LOAD
DRAWING(S)
DOWEL(S)
EA
EFEW
EL
ELECTELEV
E-W
EQ
EXISTEXP JT
EXT
=
==
=
==
=
==
==
EACH
EACH FACE
EACH WAY
ELEVATION
ELECTRICAL
ELEVATOR
EAST-WEST
EQUAL
EXISTING
EXPANSION JOINT
EXTERIOR
FF
FDNFIN
FL
FTG
=
==
=
=
FAR FACE
FOUNDATION
FINISHED
FLOOR
FOOTING
GA
GALV
GEN
=
==
GAUGE
GALVANIZED
GENERAL
H, HORHEF, H EF
HEE
Hf
HSC
==
=
=
=
HORIZONTAL
HORIZONTAL EACH FACE
HOOKED EACH END
FACTORED HORIZONTAL
FORCE, kN
HORIZONTALLY SLOTTED
CONNECTION
IFINT
==
INSIDE FACE
INTERIOR
JT = JOINT
kNkg
kN.m
kN/sq.m
kN/m
kPa
==
=
=
==
KILONEWTON
KILOGRAM
KILONEWTON METRES
KILONEWTON PER
SQUARE METRE
KILONEWTON PER METRE
KILOPASCAL
LL
LG
LLVLLH
==
==
LIVE LOAD
LONG
LONG LEG VERTICAL
LONG LEG HORIZONTAL
MAX
MC, ►
MECHMEZZ
MIN
MISCML
mm
MOM
mMPa
Mfx
Mfy
==
=
==
=
==
==
=
=
=
MAXIMUM
MOMENT CONNECTION
MECHANICALMEZZANINE
MINIMUM
MISCELLANEOUSMIDDLE LAYER
MILLIMETRE
MOMENT
METRE, METRIC
MEGAPASCAL
FACTORED BENDING
MOMENT ABOUT X-AXIS,
kNm
FACTORED BENDING
MOMENT ABOUT Y-AXIS, kNm
N
NIC
NF
N-S
NTS
==
=
==
NEWTONS
NOT IN CONTRACT
NEAR FACE
NORTH-SOUTH
NOT TO SCALE
OF
OWSJ
OPEN
==
=
OUTSIDE FACE
OPEN WEB STEEL JOISTS
OPENING
PL
PC
PROJ
==
=
PLATE
PRECAST
PROJECTION
R
RADREF
REINF
REQ'D
REV
r/w, R/W
=
==
=
=
==
RADIUS, REACTION
RADIUS
REFERENCE
REINFORCE,
REINFORCEMENT
REQUIRED
REVISION, REVISED
REINFORCED WITH
SECT
SDF
SL
SOG
SPEC'S
STD
SQ
STRUCT
=
=
==
==
=
=
SECTION
STEP DOWN FOOTING
SLAB
SLAB ON GRADE
SPECIFICATIONS
STANDARD
SQUARE
STRUCTURAL
TTEW
TMf
Tf
TJ
TLLTUL
TEMPTYP
==
=
=
=
=
==
=
TOP
TOP EACH WAY
FACTORED TORSIONAL
MOMENT, kNm
FACTORED TENSION
FORCE, kN
TIE JOIST
TOP LOWER LAYER
TOP UPPER LAYER
TEMPERATURE
TYPICAL
UL
U/N
U/S
=
=
=
UPPER LAYER
UNLESS OTHERWISE
NOTED
UNDERSIDE
WPLWWF
WWM
W/, w/
wD, wL
==
=
==
WALL PLATE
WELDED WIRE FABRIC
WELDED WIRE MESHWITH
UNIFORMLY
DISTRIBUTED LOADS
FACTORED SHEAR
FORCE, kN OR
VERTICAL
VERTICAL EACH FACE
VERTICAL BRACING
VERTICALLY SLOTTED
CONNECTION
Vf
V, VERT
VEF, V EFVBR
VSC
=
=
=
FACTORED VERTICALFORCE, kN
REINFORCEMENT DEVELOPMENT LENGTHS
TABLE 5 - COMPRESSION LAP SPLICE
LENGTH (mm)
BAR
SIZEUSUAL CONFINEMENT
10
15
2025
30
35
TABLE 4 - COMPRESSION DEVELOPMENT
LENGTH (mm)
1015
20
25
30
3545
55
f'c=25MPaf'c=20MPa
TABLE 2 - TENSION LAP SPLICE (CLASS B)
LENGTH (mm)TABLE 1 - TENSION DEVELOPMENT LENGTH
(mm)
20MPa 25MPa 30MPa 35MPa 40MPa
f'c≥30MPa
300
430
580900
1080
1260
1620
1980
300
390
530820
990
1150
1480
1810
300
370
490760
910
1060
1370
1680
300
340
460710
850
1000
1290
1570
420
630
8401315
1575
1840
380
560755
1170
1405
1640
340
510
6901070
1290
1495
315
485
640990
1180
1405
300
445600
925
1105
1300
210320
430
540
640
750970
1180
200290
380
480
580
670860
1060
200260
350
440
530
620790
970
300
440
580730
880
1020
10
15
2025
30
35
4555
320
480
640
10101210
1410
1820
2220
0301
BAR
SIZE
BAR
SIZE
NOTE: 45M AND 55M BARS SHALL BE
SPLICED WITH MECHANICAL
CONNECTORS
TABLE 6 - STANDARD HOOK DIMENSION FOR
BLACK REINFORCING.
10
1520
25
30
3545
55
180
260310
400
510
610
790
1030
140
180220
280
400
480
680
900
180
250300
400
490
590
770
1010
130
170200
280
350
430
620
830
BAR
SIZE
400R OR 500R 400W OR 500W
90° HOOK
(mm)
180° HOOK
(mm)
90° HOOK
(mm)180° HOOK
(mm)
REFER TO REINFORCING STEEL MANUAL OF
STANDARD PRACTICE FOR MORE INFORMATION.
f'c
20MPa 25MPa 30MPa 35MPa 40MPa
10
15
2025
30
35
4555
BAR
SIZE
f'c
LAP SPLICES NOT PERMITTED
TABLE 3 - DEVELOPMENT LENGTH (mm)
FOR STANDARD HOOKS.
155
240
315
390
470550
977
1261
150
210
280
350
420430
874
1128
150
190
260
320
385450
798
1030
150
175
240
295
360415
739
953
150
170
225
280
330385
691
892
20MPa 25MPa 30MPa 35MPa 40MPa
10
15
20
25
3035
45
55
BAR
SIZE
f'c
CONTINUOUS SHELF ANGLE. SUPPORT OF THE ANGLE SHALL BE AS SHOWN ON THE DRAWINGS BUT AT A MAXIMUM OF 1200o/c AND 300mm FROM ENDS AND CONTROL JOINTS.
ii. COORDINATE LOCATIONS OF CONTROL JOINTS WITH ARCHITECTURAL ELEVATIONS. CONTINUOUS LENGTH OF ANGLE IS NOT TO EXCEED 6000mm. PROVIDE A 13mm GAP BETWEEN LENGTHS.
k. SEE TYPICAL DETAILS 0405, 0406, 0407, 0408 AND 0410, AS APPROPRIATE.
050000 STRUCTURAL STEEL:
1. MATERIALS
a. WIDE FLANGE SHAPES - CONFORM TO THE REQUIREMENTS OF ASTM A992/A992M, Fy=345MPa
b. HSS MEMBERS - CONFORM TO THE REQUIREMENTS OF G40.21 350W CLASS C
i) NOTE THAT ASTM A500 IS NOT AN ACCEPTABLE ALTERNATE FOR HSS MEMBERS WITHOUT REVIEW AND RESIZING (INCREASED SECTION SIZE OR WALL THICKNESS) BY THE CONSULTANT.
c. CHANNELS AND ANGLES – CONFORM TO THE REQUIREMENTS OF CSA G40.21 GRADE 350W
d. BOLTS, NUTS AND WASHERS – "[ASTM F3125, GRADE A325]"
e. HEADED STUD- CONFORM TO CSA W59 APPENDIX H, WITH TENSILE STRENGTH OF 450MPa AND YIELD STRENGTH OF 350MPa
f. ANCHOR RODS – CONFORM TO THE REQUIREMENTS OF CSA G40.21 GRADE 300W UNLESS NOTED OTHERWISE.
g. ALL OTHER - CONFORM TO THE REQUIREMENTS OF CSA G40.21 GRADE 300W
h. STEEL JOISTS - CONFORM TO CAN/CSA-S16-09
i. METAL DECK: - CONFORM TO THE REQUIREMENTS OF CAN/CSA-S136-07.
2. EXECUTION
a. PROVIDE A MINIMUM BEARING OF 200 mm FOR ALL STEEL BEAMS BEARING ON MASONRY AND A MINIMUM OF 100 mm ON STRUCTURAL STEEL, UNLESS NOTED OTHERWISE.
b. CENTRE BEARING PLATES UNDER BEAMS, OR AS NOTED.
c. BEARING PLATE DIMENSION GIVEN FIRST INDICATES SIDE PARALLEL TO BEAM WEB.
d. NO STRUCTURAL STEEL SHALL BE CUT WITHOUT THE PERMISSION OF THE CONSULTANT.
e. WHERE COLUMNS ARE STABILIZED BY WALLS PROVIDE COLUMN ANCHORS AT ABUTTING WALLS. PROVIDE TEMPORARY BRACING UNTIL WALLS ARE BUILT TIGHT TO COLUMNS.
f. PROVIDE FRAMING AROUND ALL OPENINGS IN METAL DECK AS SPECIFIED. REFER TO TYPICAL DETAIL 0504 FOR DETAILS. SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS.
g. PROVIDE FULL HEIGHT WEB STIFFENERS AT ALL BEAMS BEARING ON COLUMNS AND ALL BEAMS SUPPORTING COLUMNS. WEB STIFFENERS SHALL BE OF THE SAME SIZE AND THICKNESS AS THE COLUMN FLANGES AND SHALL ALIGN WITH THE FLANGES OF THE SUPPORTING COLUMN.
h. CONNECT BEAMS FOR THE FACTORED REACTIONS INDICATED ON THE DRAWINGS. IF BEAM REACTIONS ARE NOT INDICATED, THE CONNECTIONS SHALL BE DESIGNED FOR ONE-HALF THE TOTAL UNIFORM LOAD CAPACITY OF THE SIMPLE SPAN BEAM FOR THE GIVEN SPAN PRESENTED IN THE CISC HANDBOOK OF STEEL CONSTRUCTION. BOLTED CONNECTIONS SHALL HAVE A MINIMUM OF TWO BOLTS.
i. DESIGNATE STEEL AS ARCHITECTURALLY EXPOSED IN ACCORDANCE WITH THE FOLLOWING TABLE. REFER TO THE SPECIFICATION FOR SPECIFIC REQUIREMENTS FOR ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS).
CATEGORY DESCRIPTION SCOPE
SSS STANDARD STRUCTURAL STEEL
ALL STRUCTURAL STEEL NOT DESIGNATED AS AESS BELOW.
AESS 1 BASIC ELEMENTS
AESS 2 FEATURE ELEMENTS (VIEWED AT A DISTANCE > 6m)
AESS 3 FEATURE ELEMENTS (VIEWED AT A DISTANCE <= 6m)
AESS 4 SHOWCASE ELEMENTS
AESS C CUSTOM ELEMENTS
j. PROTECTION: REFER TO THE SPECIFICATION FOR SPECIFIC REQUIREMENTS FOR ANY COATING SYSTEMS.
k. ALL STRUCTURAL STEEL LOCATED OUTSIDE OF THE BUILDING ENVELOPE OR EXPOSED TO HIGH HUMIDITY OR MOISTURE SHALL BE FULLY GALVANIZED IN ACCORDANCE WITH ASTM A123/A123M TO A MINIMUM ZINC COATING AS DICTATED IN TABLE 1 OF A123/A123M. WHERE GALVANIZING IS DAMAGED, THE COATING SHALL BE REPAIRED IN ACCORDANCE WITH ASTM A780/A780M.
l. ALL STEEL CONCEALED FROM VIEW AND NOT EXPOSED TO WEATHER OR HIGH HUMIDITY SHALL BE BLACK, EXCEPT AS FOLLOWS:
i) REFER TO PLANS FOR SPECIFIC ELEMENTS.
m. ALL STEEL EXPOSED TO VIEW AND NOT EXPOSED TO WEATHER OR HIGH HUMIDITY SHALL BE PRIMED (SERVICE GRADE) AND FINISHED AS PER ARCHITECTURAL, EXCEPT AS FOLLOWS:
i) REFER TO PLANS FOR SPECIFIC ELEMENTS.
053100 STEEL DECKING:
1. MATERIALS
a. STEEL DECKING PER PLAN AND CONFORMING TO CAN/CSA-S136 AND THE FOLLOWING;
i) CSSBI 10M FOR ROOF DECKING.
ii) CSSBI 12M FOR FLOOR DECKING.
b. MINIMUM ZINC COATING OF Z275 FOR EXTERIOR DECKING AND DECKING EXPOSED TO VIEW.
c. MINIMUM ZINC COATING OF ZF75 FOR INTERIOR DECKING NOT EXPOSED TO VIEW.
d. MINIMUM 1.22mm STEEL CONFORMING TO ABOVE STANDARDS FOR COVER PLATES, CELL CLOSURES, WEB STIFFENERS, EDGE STRIPS AND FLASHINGS.
e. FORM ROOF DECK WITH INTEGRAL RIBS OF A SHAPE TO MATCH EXISTING DECK WHERE REPAIR/REPLACEMENT OF EXISTING DECK IS REQUIRED.
2. EXECUTION
a. DESIGN DECK IN ACCORDANCE WITH THE REQUIREMENTS OF THE ONTARIO BUILDING CODE.
b. DESIGN AND CONNECT METAL EDGE AND CLOSURE STRIPS, METAL SCREEDS, FLASHINGS AND THE LIKE.
c. DESIGN FRAMING FOR 450mm OR SMALLER OPENINGS IN ROOF DECK, AND 300mm OR SMALLER OPENINGS IN FLOOR DECK. REINFORCE OPENINGS OVER 150mm, AS REQUIRED.
d. PLACE SHEETS IN MINIMUM 3 SPAN LENGTHS. BEAR ENDS MINIMUM 50mm.
e. LAP ENDS OF NON-COMPOSITE DECK UNITS A MINIMUM OF 50mm AND ONLY OVER SUPPORTING MEMBERS.
f. AS A MINIMUM, WELD DECK TO SUPPORTS AND PERIMETER ELEMENTS WITH 20mm PUDDLE WELDS AT MAXIMUM 400mm o/c OR EVERY SECOND FLUTE, WHICHEVER IS LESS.
g. AS A MINIMUM, FASTEN SIDE JOINTS OF DECK UNITS BETWEEN SUPPORTS BY CLINCHING AT 600mm INTERVALS OR WITH 25mm LONG WELDS AT 1000mm INTERVALS.
h. PAINT WELDS AND REPAIR DAMAGED COATING WITH GALVACON COATING.
i. DO THE FOLLOWING WHERE DECKING IS EXPOSED TO VIEW;
i) LAP ENDS OF DECK UNITS ONLY OVER SUPPORTING MEMBERS. NO SEAMS ARE PERMITTED WITHIN SPANS.
ii) KEEP DECK FREE OF DIRT, SCALE, FOREIGN MATTER, DENTS OR DEFORMATIONS.
iii) KEEP FUSION WELDS WELL WITHIN THE BEARING WIDTH OF SUPPORTING MEMBERS.
iv) AVOID WELD DAMAGE TO THE DECK OR ITS SUPPORTS.
060000 WOOD
1. MATERIALS
a. SAWN LUMBER i) CONFORM TO THE REQUIREMENTS OF CSA-O141 ii) SPECIES – SPRUCE-PINE-FIR iii) GRADE – No.1/No.2
b. PLYWOOD SHEATHING i) CONFORM TO THE REQUIREMENTS OF CSA O121 AND CSA O151 ii) FLOOR AND ROOF SHEATHING TO BE TONGUE AND GROOVE.
c. GLUED-LAMINATED TIMBER i) CONFORM TO CAN/CSA-0122 ii) SPECIES - "[DOUGLAS FIR-LARCH]" [HEM-FIR] [SPRUCE-PINE] iii) BENDING STRESS GRADE - [20f-E] [20f-EX] [24f-E] [24f-EX] iv) COMPRESSION STRESS GRADE - [12c-E] [16c-E] v) TENSION STRESS GRADE - [14t-E] [18t-E] vi) APPEARANCE GRADE - [INDUSTRIAL] [COMMERCIAL] [QUALITY]
d. CONNECTIONS
i) ALL WOOD TO WOOD CONNECTIONS OR WOOD TO STEEL CONNECTIONS, UNLESS OTHERWISE NOTED, ARE TO BE THE APPROPRIATE SIMPSON STRONG-TIE HANGER OR APPROVED EQUIVALENT, SIZED FOR THE CONNECTION FORCE AND MEMBER CONFIGURATION INDICATED.
ii) NAILS ARE TO BE COMMON STEEL WIRE NAILS CONFORMING TO THE REQUIREMENTS OF ASTM F1667 OR CSA B111. NAILS SHALL HAVE A MINIMUM DIAMETER (CORRESPONDING TO NAIL LENGTH) AS FOLLOWS: 2.87mm (FOR 57mm LONG NAILS); 3.25mm (62mm LONG); 3.66mm (76mm AND 82mm LONG); 4.88mm (102mm LONG).
iii) WOOD SCREWS ARE TO CONFORM TO THE REQUIREMENTS OF ASTM B18.6.1. REFER TO CSA O86 FOR DIAMETER AND MINIMUM YIELD STRENGTH INFORMATION.
iv) BOLTS, NUTS AND WASHERS: ASTM A307 OR SAE J429 GRADE 2. v) LAG SCREWS ARE TO CONFORM TO THE REQUIREMENTS OF ASTM B18.2.1 vi) ALL LAG BOLTS, THRU BOLTS AND OTHER HARDWARE TO BE HOT DIPPED GALVANIZED vii) ALL LAG BOLTS SHALL HAVE SHARP THREADS FOR AT LEAST ONE-HALF THE TOTAL BOLT
LENGTH, UP TO 152 mm (6”) THREADED LENGTH. LAG BOLT WITH DULL THREADS OR INSUFFICIENT THREADED LENGTH WILL BE REJECTED OUTRIGHT.
viii) UNLESS OTHERWISE APPROVED BY THE CONSULTANT, ALL NAILS ARE TO HAVE FULL ROUND HEADS; CLIPPED HEAD NAILS ARE NOT ACCEPTABLE. NAILS ARE TO BE DRIVEN FLUSH; DO NOT OVERDRIVE NAILS.
ix) HOLD DOWNS SHALL BE INSTALLED IN DOUBLE STUDS AT THE END OF THE SHEAR WALL UNLESS NOTED OTHERWISE. SHOULD THE HOLD DOWN BE LOCATED INWARD FROM THE WALL END DUE TO FIELD CONDITIONS, THE SHEATHING SHALL BE NAILED TO THE DOUBLE STUDS CARRYING THE HOLD DOWN WITH EDGE NAIL SPACING.
2. EXECUTION
a. PROTECT ALL WOOD PRODUCTS FROM DAMAGE AND STAINING DUE TO WETTING AND MOISTURE.
b. PROTECT INSTALLED DECKING AND SHEATHING FROM EXCESSIVE MOISTURE UNTIL FINAL WATERPROOFING IS COMPLETE. ENSURE SURFACES THAT ARE TO RECEIVE FINISHES MEET MANUFACTURERS REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT FOR THE FINISH SPECIFIED.
c. DIMENSION LUMBER WITH SMALLER NOMINAL DIMENSION OF 2 INCHES (“2-BY- “) PRESERVATIVE TREATED FOR EXTERIOR APPLICATIONS SHALL NOT BE INCISED. IF INCISED LUMBER IS TO BE USED, CONFIRM MEMBER SIZES WITH THE ENGINEER PRIOR TO CONSTRUCTION.
310000 FOUNDATIONS
1. A SOIL INVESTIGATION HAS BEEN COMPLETED. READ THIS REPORT, AND BE THOROUGHLY FAMILIARIZED WITH ITS FINDINGS.
2. FOUND ALL FOOTINGS AND UNDERPINNING ON NATURALLY CONSOLIDATED UNDISTURBED SOIL CAPABLE OF SAFELY SUSTAINING AN ULTIMATE BEARING VALUE OF 225 kPa AND AN ALLOWABLE BEARING VALUE OF 150 kPa.
3. FOUND FOOTINGS EXPOSED TO FREEZING BELOW THE LEVEL AT WHICH POTENTIAL DAMAGE RESULTING FROM FROST ACTION CAN OCCUR, BUT A MINIMUM OF 1200mm BELOW FINISHED GRADE IF NOT NOTED TO BE FOUNDED LOWER.
4. THE LINE OF SLOPE BETWEEN ADJACENT FOOTINGS OR EXCAVATIONS OR ALONG STEPPED FOOTINGS SHALL NOT EXCEED A RISE OF 7 IN A RUN OF 10. AT STEPS CONSTRUCT LOWER FOOTINGS PRIOR TO CONSTRUCTING HIGHER FOOTINGS.
5. DO NOT PLACE BACKFILL AGAINST WALLS RETAINING EARTH (OTHER THAN CANTILEVER WALLS) UNTIL THE FLOOR CONSTRUCTION AT TOP AND BOTTOM OF THE WALLS IS POURED AND HAS ATTAINED 70% OF ITS SPECIFIED STRENGTH.
6. CARRY OUT BACKFILLING AGAINST FOUNDATION WALLS WHERE THERE IS GRADE ON BOTH SIDES IN SUCH A MANNER THAT THE LEVEL OF BACKFILLING ON ONE SIDE OF THE WALL IS NEVER MORE THAN 500 mm DIFFERENT FROM THE LEVEL ON THE OTHER SIDE OF THE WALL.
7. PROVIDE FOOTINGS AS PER TYPICAL DETAIL 0306 FOR ALL LOAD BEARING MASONRY WALLS AND ALL NON-LOAD BEARING MASONRY WALLS THICKER THAN 190 mm. ALL NON-LOAD BEARING MASONRY WALLS 190 mm OR LESS SHALL REST ON A THICKENING OF THE SLAB ON GRADE AS PER THE TYPICAL DETAIL OR AS NOTED ON DRAWINGS.
310001 UNDERPINNING
1. REFER TO DRAWINGS FOR APPLICABLE UNDERPINNING PLANS, SECTIONS AND TYPICAL DETAILS.
2. MATERIALS:
a. CONCRETE: MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS, f’c= 25 MPa.
b. GROUT: APPROVED NON-SHRINK PRE-MIXED DRY-PACK BAG GROUT WITH A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS, f’c= 35 MPa.
3. EXECUTION
a. CONSTRUCT UNDERPINNING IN SEGMENTS WITH A MAXIMUM LENGTH OF 1200 mm (4’-0”).
b. UNDERPINNING SHALL BE CONSTRUCTED IN A MINIMUM OF THREE CONSECUTIVE STAGES AS SHOWN NUMBERED 1, 2 AND 3 ABOVE AND ON PLANS. CONSTRUCT ALL SEGMENTS NUMBERED “1”, THEN ALL SEGMENTS NUMBERED “2”, AND FINALLY ALL SEGMENTS NUMBERED “3”.
c. AT ALL TIMES, ENSURE THAT THERE IS A MINIMUM LENGTH OF 2400 mm (8’-0”) FULLY SUPPORTED ON UNDISTURBED SOIL OR ON NEW UNDERPINNING BETWEEN EXCAVATED SEGMENTS.
d. INSTALL UNDERPINNING AS FOLLOWS:
i) EXCAVATE TO THE REQUIRED ELEVATION, LEAVING A TEMPORARY BERM SLOPED AT 7V:10H AGAINST THE EXISTING FOOTING.
ii) FOR EACH SEGMENT IN TURN, EXCAVATE THE BERM AND THE SOIL UNDER THE EXISTING FOOTING FOR THE WIDTH OF THE SEGMENT.
iii) IMMEDIATELY POUR UNDERPINNING THE SAME WIDTH AS THE FOOTING, STOPPING 75 mm (3”) BELOW THE UNDER SIDE OF THE FOOTING. ENSURE THAT NO VOIDS EXIST BETWEEN THE SOIL FACE AND THE UNDERPINNING.
iv) AFTER A MINIMUM OF 48 HOURS AFTER POURING, COMPLETELY FILL THE GAP BETWEEN THE UNDERPINNING AND THE FOOTING WITH GROUT.
v) AFTER GROUT HAS ATTAINED A MINIMUM OF 50% OF ITS SPECIFIED STRENGTH, PROCEED WITH THE FOLLOWING SEGMENTS IN A SIMILAR MANNER.
vi) ADEQUATELY SHORE THE EXISTING WALL AND UNDERPINNING UNTIL THE NEW STRUCTURE CAN SAFELY SUPPORT THE LATERAL EARTH PRESSURE.
e. VERTICAL HEIGHT OF UNDERPINNING SHALL NOT EXCEED 1200 mm (4’-0”) UNLESS IT IS CONSTRUCTED IN MULTIPLE LIFTS, EACH NOT EXCEEDING 1200 mm (4’-0”).
f. WHERE UNDERPINNING HAS THE POTENTIAL TO BE BELOW THE WATER TABLE OR WHERE DRAINAGE MAY BE A PROBLEM, PROVIDE A CONTINUOUS BENTONITE STRIP AT ALL COLD JOINTS BETWEEN NEW AND EXISTING OR PREVIOUSLY POURED CONCRETE.
g. REFER TO MECHANICAL AND/OR ARCHITECTURAL DRAWINGS FOR WEEPING TILE REQUIREMENTS.
2017-12-22
0308BTYPICAL UNDERPINNING DETAILS
CLEAN U/S OF
EXIST. FOOTING
PRIOR TO POURING
NEW CONCRETE
TYPICAL UNDERPINNING FOR FROST PROTECTION AT BASEMENT WALKOUT
1:20
120
0 M
IN.
BE
LO
W G
RA
DE
75 NON-
SHRINK
GROUT
NE
W
UN
DE
RP
INN
ING
CLEAN U/S OF
EXIST. FOOTING
PRIOR TO POURING
NEW CONCRETE
EXISTING
BASEMENT SLAB
SAWCUT AND
MAKE GOOD SILL
NEW DOOR
OPENING
WALKOUT
SLAB
EXISITNG
FOUNDATION
WALL
TYPICAL UNDERPINNING DETAIL AT LOWERED BASEMENT
1:20
ALL AROUND
WEEP
ING
TILE IF
REQ
UIR
ED
50 MIN
.
SH
RIN
K
GR
OU
T1
200
MA
X.
NE
W U
ND
ER
PIN
NIN
G75
NO
N-
MAX. 10
7
ANGLE OF REPOSE
2500
MA
X. U
NS
UP
OR
TE
D H
EIG
HT
SEE PLAN
FOR SLAB
EXIST. SLAB
TO BE REMOVED
SEE PLAN
GRADE
EXISTING
FOUNDATION
WALLADJACENT
BUILDING
FOUNDATION
READ THIS DETAIL IN CONJUNCTION WITH TYPICAL
UNDERPINNING DETAIL 0308A
300
PAD OR STRIP
FOOTING
SLOPE AS PER SOIL
INVESTIGATION REPORT,
OR 7:10 (VER:HOR)
SUMP PIT NOTES:
1. REFER TO ACHITECTURAL AND MECHANICAL
DRAWINGS FOR SUMP PIT LOCATIONS.
2. WHERE SUMP PITS UNDERMINE STRIP OR PAD
FOOTINGS, LOWER THE U/S OF FOOTINGS
ELEVATIONS FROM THOSE SHOWN ON PLAN
AS PER TYPICAL DETAIL 0306.
3. THE SUMP PITS DO NOT HAVE TO BE CAST IN
PLACE REINFORCED CONCRETE. REFER TO
MECHANICAL SPECIFICATIONS FOR
REQUIREMENTS.
SLOPE AS PER SOIL
INVESTIGATION REPORT,
OR 7:10 (VER:HOR) 10@400 EACH WAY
(3 BARS BOTTOM MIN.)
200
150
SLAB REINFORCING
10
00 M
AX
.
10@250 EACH WAY
(3 BARS MIN).
PROVIDE SHORING
IN TRENCHES OVER
1200mm IN DEPTH
DURING BACKFILLING
10@250 H&V
150
500
200
25
00 M
AX
.
1-15 ALL AROUND500
0309SUMP PITS AND TRENCHES
300
OV
ER
75
0 B
UT
NO
T
GR
EA
TE
R T
HA
N 2
000
REINFORCEMENT
SEE PLAN
SAWCUT SHOWN
THUS. TYP.CONSTRUCTION
JOINT AROUND
COLUMNWIDE FLANGE COLUMNHSS OR CONC. COLUMN
300 MIN
SAWCUTS AT COLUMN
EXTEND SAWCUT
AS CLOSE AS
PRACTICAL WITHOUT
MARKING COLUMN
NOTE: U/N REFER TO ARCH
FOR SAWCUT LAYOUT
STEEL STAIRS SUPPORTED ON GRADE
STAIR
STRINGER
2-15
20
0
400
CONCRETE STAIRS SUPPORTED ON GRADE
20
0
4002-15
REINFORCEMENT
SEE PLAN
DOWELS
10@300
x 750 LONG
ISOLATION JOINT AROUND COLUMN
80±
COLUMN
POUR CONCRETE
AROUND COLUMN
MIN. 7 DAYS AFTER
POURING
SURROUNDING
SLAB
TYPICAL SAWCUTSTEPS OVER 750 BUT NOT
GREATER THAN 2000STEPS UP TO 750
CONSTRUCTION JOINT
REINF. AT MID DEPTH.
SEE PLAN (DO NOT CUT)
SAWCUT @ 25 TIMES
SLAB THICKNESS MAX.
AND LESS THAN 4.5m. c/c.
D
D/4
REINF. - SEE PLAN
500
PROVIDE SHORING
DURING BACKFILLING
10@250 EA. WAY1-15T&B
10M
@2
50 H
&V
50
0
25 COVER
150
1
1 t
REINF. - SEE PLAN
75
0
MA
X.
t
300
FIRST POURSECOND POUR
0311SLABS ON GRADE - JOINTS, STEPS, SAWCUTS, STAIRS
0308A
2 1 3 2 1
2 1 3 2 1
3 2
3 2
1
UNDERPINNING NOTES:
1. REFER TO DRAWINGS FOR APPLICABLE UNDERPINNING PLANS, SECTIONS AND TYPICAL DETAILS.
2. MATERIALS:
a) CONCRETE: MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS, f'c=25 MPa.
b) GROUT: APPROVED NON-SHRINK PRE-MIXED DRY-PACK BAG GROUT WITH A MINIMUM COMPRESSIVE
STRENGTH AT 28 DAYS, f'c=35 MPa.
3. CONSTRUCT UNDERPINNING IN SEGMENTS WITH A MAXIMUM LENGTH OF 1200 mm (4'-0").
4. UNDERPINNING SHALL BE CONSTRUCTED IN A MINUMUM OF THREE CONSECUTIVE STAGES AS SHOWN NUMBERED
1, 2 AND 3 ABOVE AND ON PLANS. CONSTRUCT ALL SEGMENTS NUMBERED "1", THEN ALL SEGMENTS NUMBERED "2",
THEN ALL SEGMENTS NUMBERED "3", AND SO ON. MAINTAIN A MINIMUM SPACING OF 2400mm BETWEEN SEGMENTS
UNDERPINNED AT THE SAME TIME (i.e. BETWEEN TWO SEGMENTS NUMBERED "1").
5. AT ALL TIMES, ENSURE THAT THERE IS A MINIMUM LENGTH OF 2400 mm (8'-0") FULLY SUPPORTED ON UNDISTURBED
SOIL OR ON NEW UNDERPINNING BETWEEN EXCAVATED SEGMENTS.
6. INSTALL UNDERPINNING AS FOLLOWS:
a) EXCAVATE TO THE REQUIRED ELEVATION, LEAVING A TEMPORARY BERM SLOPED AT 7V:10H AGAINST THE
EXISTING FOOTING.
b) FOR EACH SEGMENT IN TURN, EXCAVATE THE BERM AND THE SOIL UNDER THE EXISTING FOOTING FOR THE
WIDTH OF THE SEGMENT.
c) IMMEDIATLY POUR UNDERPINNING THE SAME WIDTH AS THE FOOTING, STOPPING 75 mm (3") BELOW THE
UNDERSIDE OF THE FOOTING. ENSURE THAT NO VOIDS EXIST BETWEEN THE SOIL FACE AND THE
UNDERPINNING.
d) AFTER A MINIMUM OF 48 HOURS AFTER POURING, COMPLETELY FILL THE GAP BETWEEN THE UNDERPINNING
AND THE FOOTING WITH GROUT.
e) AFTER GROUT HAS ATTAINED A MINIMUM OF 50% OF ITS SPECIFIED STRENGTH, PROCEED WITH THE
FOLLOWING SEGMENTS IN A SIMILAR MANNER.
7. ADEQUATELY SHORE THE EXISTING WALL AND UNDERPINNING UNTIL THE NEW STRUCTURE CAN SAFELY SUPPORT
THE LATERAL EARTH PRESSURE.
8. VERTICAL HEIGHT OF UNDERPINNING SHALL NOT EXCEED 1200 mm (4'-0") UNLESS IT IS CONSTRUCTED IN MULTIPLE
LIFTS, EACH NOT EXCEDDING 1200 mm (4'-0").
9. WHERE UNDERPINNING HAS THE POTENTIAL TO BE BELOW THE WATER TABLE OR WHERE DRAINAGE MAY BE A
PROBLEM, PROVIDE A CONTINUOUS BENTONITE STRIP AT ALL COLD JOINTS BETWEEN NEW AND EXISTING OR
PREVIOULSY POURED CONCRETE.
10. REFER TO MECHANICAL AND/OR ARCHITECTURAL DRAWINGS FOR WEEPING TILE REQUIREMENTS.
11. WHERE EXISTING SERVICES RUN THROUGH UNDERPINNING, WRAP THE PIPE WITH 50mm OF COMPRESSIBLE
MATERIAL PRIOR TO CONCRETE POUR.
STEP UNDERPINNING
SHOWN IF REQUIRED
MAXIMIM RISE = 600
MINIMUM RUN = 900
SAMPLE PLAN
NTS75 mm NON-SHRINK
GROUT, TYP.
POURED CONCRETE
UNDERPINNING1200 MAX. 1200 MAX. TYP.
SAMPLE ELEVATION
N.T.S.
TYPICAL UNDERPINNING: PLAN AND ELEVATIONS
2400 MIN.
60
0 M
AX
.
SE
E N
OT
E 8
READ THIS DETAIL IN CONJUNCTION WITH
TYPICAL UNDERPINNING DETAILS 0308B
75
MIN
.
150 MIN.
10M BARS @800 c/c
EPOXY INTO HOLES
DRILLED INTO WALL
1-15T
CONT.
EXISTING SLAB
TO BE REMOVED
EXIST. FOUNDATION
WALL
EXISTING FOOTING
UNDISTURBED
SOIL
1-15 CONT.
150 MIN.
10
7 MAX.
50
MIN
.
ALL
AR
OU
ND
LOCATION OF
WEEPING TILE
IF REQUIRED REFER TO
ARCH. OR MECH. DWGS
CONCRETE SLAB
SEE PLAN
CONSTRUCTION JOINT
IF REQUIRED
TYPICAL SECTION THROUGH BENCHING
NOTES:
1. CONFORM TO THE REQUIREMENTS OF THE ONTARIO BUILDING CODE 2006 AND ANY
APPLICABLE ACTS OF AUTHORITIES HAVING JURISDICTION.
2. MATERIALS:
CONCRETE - 25 MPa AT 28 DAYS WITH A SLUMP OF 50 TO 110 mm.
REINFORCING STEEL - MINIMUM YIELD STRENGTH Fy=400 MPa.
EPOXY ANCHORS - HILTI HY150 INJECTION ADHESIVE ANCHORS OR APPROVED EQUAL.
3. DO WORK IN A MANNER THAT AVOIDS DAMAGE TO ADJACENT STRUCTURES, UTILITIES,
ROADS AND SIDEWALKS.
4. PROVIDE ALL BRACING, SHORING AND NEEDLING NECESSARY FOR THE SAFE EXECUTION
OF THE WORK.
5. WHERE THERE IS SOIL PRESSURE AGAINST THE EXTERIOR FACE OF THE EXISTING WALL,
PROVIDE ADEQUATE LATERAL RESTRAINT TO THE BOTTOM OF THE WALL UNTIL THE NEW
BENCHING AND SLAB ON GRADE ARE INSTALLED AND THE CONCRETE HAS ACHIEVED AT
LEAST 50% OF ITS SPECIFIED STRENGTH.
6. ENSURE THAT THE SOIL BELOW A 7 IN 10 SLOPE FROM THE EDGE OF THE EXISTING WALL
FOOTING IS UNDISTURBED.
7. PROVIDE ADEQUATE DRAINAGE TO PREVENT AN ACCUMULATION OF WATER.
TYPICAL SECTION THROUGH BENCHING 0307
10M @ 400 o/c DOWELS
190 NON LOAD
BEARING CONC.
BLOCK WALL
2-15 CONT. LAP
AT CORNERS AND
JUNCTIONS.
20
0
400
SLAB ON
GRADE
IF TOTAL HEIGHT OF STEPPING "D"
EXCEEDS 2000, PROVIDE INTERMEDIATE
HORIZONTAL SECTIONS WITH A MINIMUM
HORIZONTAL LENGTH OF 1200 BETWEEN
STEPPED FOOTINGS.SLAB THICKENING UNDER 140mm
AND 190mm NON LOAD BEARING WALLS
MASONRY WALL
2-15 CONT.
LAP AT CORNERS
AND JUNCTIONS
OF FOOTINGS
100 TYP. U/N
200
TY
P.
U/N
STRIP FOOTING FOR ALL LOAD BEARING
WALLS AND THOSE NON LOAD BEARING
GREATER THAN 190mm THICK
WHEN 'B' EXCEEDS 2000 mm
FOOTING SHALL BE STEPPED
DOWN FROM BOTH SIDES
B
WALL
FTGt
UNDISTURBED
SOIL
t M
IN.
50 mm OF APPROVED HIGHLY
COMPRESSIBLE MATERIAL
AROUND PIPE RUNS.
PROVIDE 10 MPa CONCRETE
BACKFILL WHERE EXCAVATION
RUNS ACROSS AND UNDER THE
LINE OF FOOTING
PIPES CROSSING BENEATH
CONT. WALL FOOTINGSRELATION TO ADJACENT FOOTINGS AND EXCAVATIONS
ADJUST FOOTING ELEVATIONS SHOWN ON
DRAWINGS IF NECESSARY TO MAINTAIN THE
MAX. 7 TO 10 SLOPE BETWEEN FOOTINGS AND
ADJACENT EXCAVATIONS FOR DRAINS OR
OTHER ITEMS
10
7
200
TY
P.
U/N
450 F
OR
10M
& 1
5M
600 F
OR
≥ 2
0M
PROVIDE 38X89 KEY AT
WALLS 200 THICK AND
OVER
1-15 CONT.
100 TYP. U/N
PROVIDE INSIDE FACE
VERTICAL DOWELS SAME
SIZE AND SPACING AS
VERTICAL WALL REINFORCING
FOR WALLS RETAINING EARTH
TYPICAL STEPPING DETAIL FOR STRIP FOOTINGS
MARKED SDF (STEP DOWN FOOTING) ON PLAN
STRIP FOOTINGS FOR
CONCRETE WALLS
7
10LINE OF
EXCAVATION
MAINTAIN
STABLE SLOPE
WALL FOOTINGS 0306
1
2
600 MIN.
D
600 M
AX
.
600 MIN.
OF
ST
RIP
FO
OT
ING
T=
DE
PT
H
STAGGERED U/S
FOOTING
300
MIN.
DOWEL TO MATCH VERT.
REINF. IN WALL
WHERE IeFaSa(0.2)≥0.35
DOWEL TO MATCH VERT.
REINF. IN WALL
WHERE IeFaSa(0.2)≥0.35
2017-12-22
0312CONCRETE WALLS
DOWELS SAME SIZE
& SPACING AS
HORIZONTAL WALL
REINFORCING
38x89 KEY AT
CONSTRUCTION
JOINTS
CORNER BARS SAME
SIZE & SPACING AS
HORIZONTAL WALL REINF.
ANCHORAGE "A"
500 FOR 10 & 15 BARS
600 FOR 20 & LARGER
DISPLACE VERTICAL AND
HORIZONTAL REINF. AT
LOCATION OF OPENING TO
EITHER SIDE OF OPENING
1-15 x1500 LG
FOR WALLS UP TO
200 WALLS, & 1-15
EACH FACE FOR WALLS
OVER 200. HOOK AS
NECESSARY.
ADD MIN REINF
WITH HOOK
ABOVE, BELOW
AND ON EA
SIDE OF OPENING
15@400 DOWELS TO
FLOOR SLAB UNLESS
NOTED OTHERWISE
ON DRAWINGS
38x89 KEY TYP.
1-15 CONT.
DETAIL OF REINFORCING AT
OPENINGS OR RECESSES IN
CONCRETE WALLS
1200 MAX.
REINFORCING AT
INTERSECTIONS OF WALLS
A
A
REINFORCING AT CORNERS
OF WALLS
600 M
IN.
DETAIL AT TOP OF
WALL/GRADE BEAM
600
MIN
.
600 MIN.
OPEN
300
X
0313A
1 LAYER
15@500
15@500
10@300
10@400
10@500
10@300
15@500
15@500
15@500
15@500
15@500
10@400
400350
300
250
200150
W400W350
W300
W250
W200W150
PLACE HORIZONTAL
BARS ON ALTERNATING
SIDES OF VERTICALS
1-20 M
TYPICAL
CONCRETE WALL REINFORCING
PROVIDE ADDITIONAL TIES
(SHOWN DASHED) WHEN
X>150mm
NOMINALLY REINFORCED WALLS
WALLS WITH 2 LAYERS OF REINFORCINGWALLS WITH 1 LAYER OF REINFORCING
2-20M
FOR WALLS > 200
THICK PROVIDE
10M U-BAR @ SAME
SPACING AS
HORIZONTAL BARS
NOTES:
1. UNLESS NOTED OTHERWISE ON THE DRAWINGS, PROVIDE THE REINFORCING SHOWN ABOVE
IN ALL CONCRETE WALLS.
2. SEE PLAN FOR WALL MARKS
3. CONFORM TO DETAILS BELOW FOR ADDITIONAL TIES.
4. FOR WALL THICKNESS BETWEEN THOSE SCHEDULED, PROVIDE REINFORCING AS FOR THE
NEXT THICKER WALL.
5. 20M AT ENDS OF WALLS TO BE TENSION LAPPED WITH REBAR ABOVE.
6. SEE DETAIL 0313B FOR ADDITIONAL INFORMATION AT WALL OFFSETS.
7. DO NOT USE FOR FOUNDATION WALLS.
REMARKSHORIZONTAL
BARS
EACH FACE
VERTICAL BARS
EACH FACETHICKNESSMARK
PROVIDE 10M TIES WHEN
DISTRIBUTED
VERTICAL BAR SIZE
EXCEEDS 20M t
AB
DOWELS AS
INDICATED
(PROVIDE
15M@500 MIN.)
75 MIN.
t/2
DOWELS AS
INDICATED
(PROVIDE
15M@500 MIN.)
75 MIN.t/2
t
THIRD
POURSECOND
POUR
FIRST
POUR
HORIZONTAL JOINTS AT SLAB
AB
HORIZONTAL JOINT
PROVIDE
SPECIFIED
WATERSTOP
IN ALL
HORIZONTAL
JOINTS MORE
THAN 600mm
BELOW GRADE.
REGLET FOR
ARCHITECTURAL
CONCRETE
ONLY. FOR
CONFIGURATION
SEE
ARCHITECTURAL
AND/OR
STRUCTURAL
DRAWINGS.
FIRST
POUR
38mm X 89mm KEY IN WALLS
250mm THICK OR GREATER.
US
E B
IF
EA
RT
H
IS P
RE
SE
NT
ON
OP
PO
SIT
E S
IDE
.
SECOND
POUR
A O
R B
100 M
IN.
REGLET FOR ARCHITECTURAL
CONCRETE ONLY. FOR
CONFIGURATION SEE
ARCHITECTURAL AND/OR
STRUCTURAL DRAWINGS.TIE WATERSTOP TO
REBAR AT 600 MAX.
(TYPICAL)
FIRST POUR
PROVIDE
SPECIFIED
WATERSTOP
WHEN EXPOSED
TO EARTH OR
WEATHER. EXTEND
TO TOP OF
FOOTING OR
300mm MAXIMUM
BELOW SLAB
ON GRADE.
SECOND
POUR
75 MIN.75 MIN.
B
0314CONSTRUCTION JOINTS IN WALLS
VERTICAL JOINT
SPLICE LENGTHS
A - REFER TO TABLE 5, DETAIL 0301
B - REFER TO TABLE 2, DETAIL 0301. INCREASE BY
50% IF EPOXY-COATED BAR IS USED.
0315CONTROL AND EXPANSION JOINTS IN CONCRETE WALLS
EXPANSION JOINT
CONTROL JOINT
NOTES:
1. AS A MINIMUM PROVIDE CONTROL JOINTS IN ALL FOUNDATION WALLS
AT 30 TIMES THE WALL THICKNESS.
2. PROVIDE CONTROL JOINT AT ALL LOCATIONS MARKED THUS IN
PLAN
CUT EVERY OTHER HORIZONTAL
BAR EXCEPT CONTINUOUS TOP
AND BOTTOM BARS.
REGLET FOR ARCHITECTURAL
CONCRETE ONLY.
FOR CONFIGURATION
SEE ARCHITECTURAL AND/OR
STRUCTURAL DRAWINGS.
19 mm X 19 mm REGLET IN CONCRETE
WALLS EXPOSED TO VIEW BUT NOT
DESIGNATED AS ARCHITECTURAL CONCRETE.
75
MIN.75
MIN.
EXPOSED FACESEALING COMPOUND
AS SPECIFIED.
SPECIFIED WATERSTOP SPECIFIED FILLER
3030
SEE DRAWINGS
75 75
15M@400T
U/N
2-15M CONT. T+B
AT UNSUPPORTED
SLAB EDGESAT CANILEVER
SLAB, EXTEND
INTO SLAB
1.5 x CANTILEVER
LENGTH
A 1.5 x A
TOP BAR
BE
YO
ND
SU
PP
OR
T
BE
LO
W
100
0 T
YP
.
BEAM OR
WALL BELOW
BEAM OR
WALL BELOW
NOTES:
1. TOP BARS SHALL BE CARRIED 24 Ø INTO
THE SUPPORT OR HOOKED AS SHOWN
DOTTED.
2. L IS GREATER OF L1 AND L2.
3. IN ALL ONE WAY SLABS PROVIDE
TEMPERATURE REINFORCEMENT
PERPENDICULAR TO THE SPAN AS PER
THE TABLE BELOW, UNLESS OTHERWISE
NOTED ON PLAN. LAP TEMPERATURE
REINFORCEMENT 24 Ø, BUT NOT LESS
THAN 300 mm.
REINFORCING FOR CRACK CONTROL
10 @ 500
10 @ 400
10 @ 300
15 @ 500
15 @ 450
15 @ 400
15 @ 350
20 @ 500
20 @ 400
20 @ 400
10 @ 500
10 @ 500
10 @ 400
10 @ 325
15 @ 500
15 @ 500
15 @ 450
15 @ 400
15 @ 350
20 @ 500
75
100
125
150
175
200
225
250
275
300
SLABS EXPOSED TO WEATHER
As = .0025 AgINTERIOR SLABS
As = .002 AgSLAB
THICKNESS
CUT SHORT NOT
MORE THAN HALF
OF STEEL
0.125 L1
0.20 L
0.30 L
0.20 LSE
E N
OT
E 3
TOP BARTOP BARS
BOTTOM BARS
SE
E N
OT
E 3
0.30 L
150 MIN TYP.
PLAN DETAIL
L2
24 Ø OR 450 MIN.
BUT IN NO CASE
LESS THAN WIDTH
OF BEAMS PLUS
STANDARD HOOK
TYPICAL ALL
EDGES
CARRY 0.25L INTO
ADJACENT BUT NON-
CONTINUOUS SLAB
L1
0.25 L1
L/5
L/5
L/5
L/5
L/5 L/5
0317ONE-WAY SLABS
BEAM OR
WALL BELOW
0.25 L1
TOP BAR
TOP BAR
1.5 x A
CARRY 0.25L INTO
ADJACENT BUT NON-
CONTINUOUS SLAB
24 Ø OR 450 MIN.
BUT IN NO CASE
LESS THAN WIDTH
OF BEAMS PLUS
STANDARD HOOK
TYPICAL ALL
EDGES
A
AT CANILEVER
SLAB, EXTEND
BARS INTO SLAB
1.5 x CANTILEVER
LENGTH 0.2
5 L
4
L4
0.10 L1
0.1
0 L
4
L1
0318TWO-WAY SLABS
ALTERNATE BOTTOM
BARS SHORT AT
CONTINUOUS ENDS
EXTEND MIN 50% OF BOTTOM STEEL TO
WITHIN 75 FROM FACE. PROVIDE MINIMUM
50 COVER. TYPICAL ALL EDGES
10Ø MINIMUM
TYPICAL ALL
EDGES
L3
L2
PLAN DETAIL
150 M
IN
150 MIN
0.30 L0.30 L
0.3
0 L
0.3
0 L
TO
P B
AR
BOTTOM BARS
TOP BAR
BO
TT
OM
BA
RS
TO
P B
AR
NOTES:
1. L IS LONGER OF L1 AND L2 OR L3 AND L4 (i.e. LONGER OF ADJACENT SPANS).
2. PROVIDE AT LEAST 4-15M SUPPORT BARS FOR ALL TOP BARS. SUPPORT BARS SHALL
REST ON CHAIRS.
3. HOOK BOTTOM BARS WHERE REQUIRED TO ACHIEVE EMBEDMENT INDICATED.
4. SEE PLAN FOR PLACING ORDER OF BARS.
2017-12-22
NOTE:
1. LINTELS DESCRIBED ON THIS TYPICAL DETAIL ARE FOR NON-LOAD BEARING WALLS. THE LINTELS SHALL ONLY
BE USED IN LOAD BEARING MASONRY WALLS IF REVIEWED BY THE CONSULTANT.
2. PROVIDE STEEL PACKING PLATES UNDER THE ENDS OF LINTELS AS REQUIRED TO ENSURE EVEN BEARING
3. FOR OPENINGS OVER 600mm IN WIDTH, BOLT DOUBLE ANGLES BACK TO BACK USING 16mm DIAM. BOLTS AT
450mm C/C. PROVIDE BOLTS 75mm FROM EACH END. ALTERNATIVELY, PROVIDE 6mm X 50mm LONG FILLET WELDS
AT 450mm C/C TOP AND BOTTOM.
4. FILL LINTEL BLOCKS WITH CONCRETE GROUT IN CONFORMANCE WITH CSA STANDARDS.
5. PROVIDE 200mm MINIMUM LENGTH OF BEARING AT EACH END. PROVIDE A MINIMUM LENGTH OF 200mm AND
A MINIMUM DEPTH OF 400mm OF 100% SOLID MASONRY BELOW THE LINTEL BEARING EACH END.
6. WHERE LINTELS ABUT CONCRETE COLUMNS AND WALLS, OR STEEL MEMBERS, PROVIDE L100X100X10
ANCHORED TO CONCRETE WITH 2-20mm DIAM. BOLTS WITH ADJUSTABLE ANCHORS, OR WELDED TO STEEL
FOR V=10kN
7. HORIZONTAL REINFORCEMENT SHALL EXTEND 200mm BEYOND FACE OF OPENING
8. LINTELS IN EXTERIOR WALLS EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED.
9. VERTICAL CONTROL JOINTS SHALL NOT BE LOCATED IN LINE WITH WALL OPENINGS. REFER TO TYPICAL DETAIL
0409 FOR CONTROL JOINTS IN MASONRY WALLS.
WALL TYPE
90 SOLID WALL
140 SOLID WALL
190 SOLID WALL
240 SOLID WALL
290 SOLID WALL
90 + 90
CAVITY WALL
90 + 140
CAVITY WALL
90 + 190
CAVITY WALL
90 + 240
CAVTIY WALL
90 + 290
CAVITY WALL
UP TO 1200 SPAN OVER 1200 BUT NOT MORE
THAN 1800 SPAN
OVER 1800 BUT NOT MORE
THAN 2200 SPAN
LINTEL BLOCK REINF.
WITH 1-10M T & B
LINTEL BLOCK REINF.
WITH 1-15M T & B
2Ls - 89X89X7.9
2Ls - 102X102X7.9
3Ls - 89X89X7.9
1L - 89X89X7.9 +
LINTEL BLOCK REINF.
WITH 1-10M T& B
1L - 89X89X7.9 +
LINTLE BLOCK REINF.
WITH 1-15M T & B
1L - 89X89X7.9 +
2Ls - 89X89X7.9
1L - 89X89X7.9 +
2Ls - 102X102X7.9
1L - 89X89X7.9 +
3Ls - 89X89X7.9
LINTEL BLOCK REINF.
WITH 1-15M T & B
LINTEL BLOCK REINF.
WITH 1-15M T & B
2Ls - 102X89X7.9
2Ls - 102X102X9.5
3Ls - 127X89X7.9
1L - 102X89X7.9 +
LINTEL BLOCK REINF.
WITH 1-15M T & B
1L - 102X89X7.9 +
LINTEL BLOCK REINF.
WITH 1-15M T & B
1L - 102X89X7.9 +
2Ls - 102X89X7.9
1L - 102X89X7.9 +2Ls - 102X102X9.5
1L - 102X89X7.93Ls - 127X89X7.9
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
2Ls - 127X89X7.9
2Ls - 152X102X7.9
3Ls - 152X102X7.9
1L - 127X89X7.9 +
2Ls - 127X89X7.9
1L - 127X89X7.9 +
2Ls - 152X102X7.9
1Ls - 127X89X7.9 +
3Ls - 152X89X7.9
LINTELS FOR MASONRY WALLS 0402
L89X89X7.9 L102X89X7.9 L127X89X7.990 VENEER
DETAIL AT BEAM
(EXPOSED TO VIEW)
20 m
m
GA
P, U
/N
75
200 t WALL
25mm GAP FILLED WITH
COMPRESSIBLE MATERIAL
ANCHORAGE TO METAL DECK
CLIP FABRICATED FROM
12GA. PLATE OR USE
MANUFACTURED EQUIVALENT
25mm GAP FILLED WITH
COMPRESSIBLE MATERIAL
ANCHOR TO SLAB
WITH 2-8Ø
EXPANSION ANCHORS
PROVIDE CLIPS FOR BLOCK
TIES @400 o/c WELDED
TO WEB OF BEAM
ANCHORAGE TO STEEL BEAM
ANCHOR TO SLAB
WITH 2-8Ø
EXPANSION ANCHORS
25mm GAP FILLED WITH
COMPRESSIBLE MATERIAL
ANCHORAGE TO CONCRETE SLAB
L76x76x4.8
x150LG.
NOTES:
1. PROVIDE TOP LATERAL SUPPORTS FOR ALL MASONRY WALLS WHEN SPACING BETWEEN
RETURN WALLS EXCEEDS 20t FOR EXTERIOR WALLS, AND 36t FOR INTERIOR PARTITIONS.
2. SPACING OF LATERAL SUPPORTS SHALL NOT EXCEED 1200 o/c.
CLIP FROM
L76x76x4.8
x150LG
STAGGERED
L127x76x6.4 CLIP
ANGLE x75LG
c/w 12x50 VERT.
SLOTTED HOLE
10M BAR x600 LG.
GROUTED SOLID
INTO BLOCK
DO NOT GROUT
CLIP ANGLE
INTO BLOCK
ANCHORAGE TO STEEL BEAM
DETAIL AT BEAM
(CONCEALED FROM VIEW)
20 m
m
GA
P,
U/N
LATERAL SUPPORT AT TOP OF MASONRY PARTITIONS 0403
0409MASONRY CONTROL JOINTS
FILL VOID WITH MORTAR 1-15M EA. SIDE OF JOINT
BUILDING PAPER
STOP HORIZONTAL REINFORCEMENT
AT CONTROL JOINT
BACKER ROD AND JOINT SEALANT
400MIN.
ELEVATION SHOWING CONTROL JOINTS AT OPENINGS WITH REINFORCED MASONRY LINTELS
ELEVATION SHOWING CONTROL JOINTS AT OPENINGS WITH STEEL LINTELS
REINF. EACH SIDE OF OPENING
AS INDICATED IN TYP. DETAIL 0401PROVIDE CONTROL JOINT ON BOTH SIDES
FOR OPENINGS OVER 1800
9000 MAX.
LOCATE CONTROL JOINT
AWAY FROM OPENING LOCATE CONTROL JOINT
AWAY FROM OPENING
PROVIDE CONTROL JOINT ON ONE SIDE
FOR OPENINGS UNDER 1800
LINTEL REINF. AS SPECIFIED
800 MIN.
CONTROL JOINT PLAN DETAIL
ADD HOR. JOINT REINF. IN FIRST
MORTAR JOINT BELOW OPENING
IF NOT ALREADY PRESENT
200 MIN.
STEEL LINTEL
REINF. EACH SIDE OF OPENING
AS INDICATED IN TYP. DETAIL 0401
CLEAN OUT TO BE
PROVIDED AT ALL
BAR LOCATIONS
SEE NOTE 8
84
0 L
AP
(2
0M
)
63
0 L
AP
(15M
)800, TYP.
CONTROL JOINT
INTERSECTION
JAMB STEEL OFFSET
300 FROM OPENING
CORNER OR
END OF WALL
NOTES:
1. UNLESS NOTED OTHERWISE, PROVIDE 1-15M VERTICAL ADJACENT TO ALL OPENINGS, AT WALL ENDS,
CORNERS AND INTERSECTIONS, AND ON EACH SIDE OF CONTROL JOINTS.
2. UNLESS NOTED OTHERWISE, PROVIDE 2-WIRE (3.66Ø) LADDER TYPE HORIZONTAL JOINT
REINFORCING @400mm o/c.
3. FULLY FILL ALL BLOCK CELLS CONTAINING BARS WITH GROUT OF POURABLE CONSISTENCY AS PER CSA
STANDARDS.
4. ALL BED JOINTS TO BE LAID WITH TYPE "S" MORTAR.
5. WHERE STEEL COLUMN INTERSECTS BLOCK WYTHE, BUILD BLOCK TIGHTLY AGAINST COLUMN AND
CONNECT TO IT WITH STEEL BAR OR STRAP ANCHORS CAPABLE TO RESIST 5kN FACTORED TENSION
AND SHEAR AT THE SAME SPACING AS THE HORIZONTAL REINFORCEMENT.
6. REFER TO PLANS AND WALL SCHEDULES FOR SPECIFIC WALL REINFORCEMENT. REINFORCE AS
INDICATED BUT NOT LESS THAN THAT SHOWN ON THIS TYPICAL DETAIL.
7. PROVIDE DOWELS FROM CONCRETE FOUNDATION WALLS TO MATCH VERTICAL REINF. IN MASONRY ABOVE.
8. PROVIDE CLEANOUTS AT BASE OF WALL TO ENSURE COMPLETE GROUTING OF VOID. MAXIMUM HEIGHT OF
GROUTING TO BE 2400 mm. IF CLEANOUT CANNOT BE PROVIDED BECAUSE OF EXPOSED MASONRY, LIMIT
HEIGHT OF GROUT POUR TO 1200 mm.
9. REFER TO TYPICAL DETAIL 0409 FOR CONTROL JOINTS IN MASONRY WALLS.
MINIMUM WALL REINFORCING
PROVIDE LADDER
TIE AT GRADE
LADDER TIES
AS SPECIFIED
REINFORCING IN MASONRY WALLS 0401
VERTICAL BARS
AS SPECIFIED
500
LA
P (
10m
)
PROVIDE CONTINUOUS
BOND BEAM r/w 1-15M
TYPICAL AT TOP OF EACH
LIFT OF WALL
NOTE: DOWELS BACK TO BASE
STRUCTURE TO MATCH REINF. IN WALL.
SEE PLAN FOR DETAIL WHERE MASONRY
WALL NOT SUPPORTED ON
CAST IN PLACE CONCRETE
NON-LOAD-BEARING WALLS
WALL HORIZONTAL
THICKNESS VERTICAL (LADDER-TYPE JOINT REINFORCING)
140 10M@800 o/c 2-3.66Ø @400 o/c
190 10M@800 o/c 2-3.66Ø @400 o/c
240 10M@800 o/c 2-3.66Ø @400 o/c
290 10M@600 o/c 2-4.76Ø @400 o/c
2017-12-22
0501CONCRETE SLAB ON STEEL DECK FRAMING DETAILS
UNLESS NOTED OTHERWISE,
PROVIDE DECK MANUFACTURER
RECOMMENDED POUR STOP
CONTINUOUS AROUND OPENING
DETAIL AT FRAMED OPENINGS
CONNECT BRIDGING FOR
FORCES INDICATED ON
JOIST DRAWINGS
IF REQUIRED, PROVIDE
MANUFACTURER
RECOMMENDED
POUR STOP, U/N.
20
0
MIN
.
150x10x100 PLATE
c/w 2-12Ø w/ 50 HOOK
ANCHOR BOLTS AT
BRIDGING LOCATIONS
65x6 CONTINUOUS STRIP
c/w 12Ø x300LG. w/ 75 HOOK
ANCHOR BOLTS @1200 o/c
150 MIN.
75
10M x1200LG. @300 o/c
CENTRED OVER BEAM
MID-DEPTH OF SLAB
NOTES:
1. WHEN THE JOIST FRAME ONTO BEAM FROM ONE SIDE ONLY, CENTRE JOIST
SHOE OVER BEAM CENTRE LINE.
2. OFFSET JOISTS IF BEAM FLANGE IS LESS THAN 130 WIDE.
10 MAX.
65 MIN. BEARING
NOTES:
1. PROVIDE CONTINUOUS PERMANENT BRIDGING FOR TOP AND BOTTOM JOIST CHORDS IN
ACCORDANCE WITH CSA S16.
2. TAKE ALL NECESSARY PRECAUTIONS WHEN POURING CONCRETE SLAB OVER STEEL DECK TO PREVENT
LARGE CONCENTRATIONS OF CONCRETE WHICH MIGHT LOCALLY OVERSTRESS THE DECK.
3. IF NECESSARY, OFFSET JOIST BEARING AND/OR ANY CONNECTION PLATE FROM MASONRY CONTROL
JOISTS.
4. PROVIDE A MINIMUM DEPTH OF 200mm OF 100% SOLID MASONRY UNITS FOR STEEL JOISTS BEARING
ON MASONRY.
CLOSURE ANGLE AS SPECIFIED.
IF NONE SPECIFIED, PROVIDE
POUR STOP AS SPECIFIED BY
DECK MANUFACTURER.
AS SPECIFIED
REFER TO DETAILS
0502METAL DECK AND FRAMING SUPPORTED BY MASONRY
NOTES:
1. OFFSET JOISTS IF WALL IS LESS THAN 190mm THICK.
2. OFFSET JOISTS AND ANY CONNECTION PLATES FROM
CONTROL JOINTS IN MASONRY WALLS.
3. CUT ANCHOR BOLTS AND WELD TO LINTELS WHERE LENGTH
OF ANCHOR BOLT INTERFERES WITH LINTEL.
DECK FRAMING ONTO MASONRY BEARING WALL
JOISTS FRAMING ONTO MASONRY BEARING WALL
150x10x100 PLATE
c/w 2-12Ø w/ 50 HOOK
ANCHOR BOLTS AT
BRIDGING LOCATIONS
150 MIN.
GROUT SOLID
MIN. 400 LG.
600
GROUT SOLID
MIN. 400 LG.
10M BAR x2000 LG. GROUTED IN
VOID. CENTRE BENEATH JOIST
SHOE/BEARING PLATE
BEARING PLATE w/ 2-16Ø x600LG.
ANCHOR RODS w/ 75 HOOK OR
STANDARD NUT AND WASHER
90 MIN.
75 MIN.10 MAX.
45 MIN. TO CENTRE
LINE OF JOIST SHOE
CONT. TRIM
ANGLE AS INDICATED
ON DRAWINGS
15M x450LG. REBAR
THROUGH HOLE
IN L152x152
L152x152x8 x150LG.
IN MORTAR JOIST @800 o/c
START NO FURTHER THAN
150mm FROM CONTROL JOINTS
55
CONTINUOUS L64x64x6.4
CUT AT MASONRY
CONTROL JOISTS
55
MO
RE
TH
AN
600
LE
SS
TH
AN
600
WHERE LINTEL INTERFERES
WITH BOLTS, CUT BOLTS
AND WELD TO LINTEL
19Ø x650LG. ANCHOR
BOLTS GROUTED @800 o/c
c/w 90x6x90 END PLATE
65x6 CONTINUOUS BEARING
STRIP ON 15mm GROUT BED.
CUT STRIP AT CONTROL
JOINTS IN MASONRY WALL.
5±
0503STEEL DECK FRAMING DETAILS
TRIMMER ANGLE SPLICE
L38x38x3.2 CONT.
BY DECK ERECTOR TYP.
AS REQUIRED WHERE
HIGH FLUTE OCCURS AT
EDGE. DO NOT BEND
HIGH FLUTE DOWN.
40-300340-3003
ROOF DIAPHRAGM
CONNECTION, WELD AS
SPECIFIED
WELD FOR FULL
TENSILE CAPACITY
SPLICE ANGLE OF EQUAL OR
GREATER CROSS-SECTIONAL AREA
AS TRIM ANGLE
BEVEL HEEL OF SPLICE ANGLE TO FIT
CONT. TRIM
ANGLE AS
SPECIFIED.
STEEL BEAM PARALLEL TO STEEL DECK
WELD DECK TO FLANGE
AT 500 o/c MAX.
CHANGE IN SPAN DIRECTION OF STEEL DECK
PROVIDE CONT. ANGLE
(L64x64x6.4 OR L102x76x6.4 LLV
TO SUIT JOIST SHOE DEPTH)
WELDED TO BEAM AND JOISTS
TO SUPPORT EDGE OF DECK
75-300575-3005
HSS SHEAR TRANSFER
MEMBER CONT. BETWEEN JOISTS.
DEPTH TO MATCH JOIST SHOE.
MIN. 152 WIDE, 4.8 WALL
CONT. TRIM
ANGLE AS INDICATED
ON DRAWINGS
NOTES:
1. WHEN THE JOIST FRAME ONTO BEAM
FROM ONE SIDE ONLY, CENTRE JOIST
SHOE OVER BEAM CENTRE LINE.
2. OFFSET JOISTS IF BEAM FLANGE IS
LESS THAN 130 WIDE.
DE
PT
H A
S
IND
ICA
TE
D
ON
DW
GS
.
JO
IST
SH
OE
65 MIN. BEARING
10 MAX.
0504FRAMING FOR ROOFTOP UNITS AND OPENINGS IN DECK
FRAMING FOR ROOFTOP MECHANICAL UNITS
OPENINGS IN METAL ROOF DECK
NOTES:
1. UNLESS SHOWN OTHERWISE ON PLAN, PROVIDE C150x12 SPANNING BETWEEN BEAMS OR JOISTS EACH SIDE
OF ROOFTOP UNIT, AS WELL AS AT EACH END, IN THE MANNER INDICATED ABOVE. CHANNELS TO BE LOCATED
DIRECTLY UNDER CURBS SUPPORTING UNIT. OMIT CHANNEL IF CURB IS DIRECTLY OVER A BEAM OR JOIST.
2. PROVIDE C100x8 TO SUPPORT EDGES OF DECK AT OPENINGS IN THE MANNER INDICATED ABOVE. IF THE
DECK UNDER THE ENTIRE UNIT IS TO BE OMITTED, THE C100x8 FRAMING CAN BE DELETED.
3. CONNECT C150x12 TO SUPPORTING BEAMS OR JOISTS FOR A MINIMUM WORKING LOAD OF 9kN OR 14 OF THE WEIGHT OF THE UNIT PLUS 5kN, WHICHEVER IS MORE. CONNECT WITHOUT DAMAMGING THE SUPPORTING
STEEL.
4. CONNECT C100x8 TO SUPPORTS FOR A MINIMUM WORKING LOAD OF 5 kN.
5. COORDINATE LOCATION AND SIZE OF UNIT AND OPENINGS, AND LOCATION OF STEEL FRAMING WITH THE
MECHANICAL CONSULTANT AND/OR MECHANICAL CONTRACTOR AND THE STRUCTURAL CONSULTANT.
6. THIS DETAIL APPLIES TO NEW CONSTRUCTION ONLY.
OP
EN
OPEN
C100x8
C150x12 C150x12
C150x12C150x12
C100
x8
C1
50x1
2
C1
00x8
C1
50x12
OUTLINE OF
ROOFTOP UNITBEAM OR JOIST
BEAM OR JOIST
METAL DECK
NOTES:
1. OPENINGS UP TO 150mm SQUARE OR IN DIAMETER AND SPACED
A MINIMUM 300mm CLEAR FROM ADJACENT OPENINGS DO NOT
REQUIRE REINFORCING.
2. OPENINGS LARGER THAN 150mm, BUT NOT EXCEEDING 450mm,
ARE TO BE REINFORCED BY THE METAL DECK SUPPLER AS
REQUIRED.
3. OPENINGS LARGER THAN 450mm UP TO MAXIMUM 1200mm
SQUARE ARE TO BE REINFORCED AS SHOWN ABOVE, UNLESS
INDICATED OTHERWISE ON PLAN.
4. CONNECT FRAMING FOR A MINIMUM END REACTION OF 10 kN.
450
MIN
.
12
00 M
AX
.
OP
EN
C1
50x12
C1
50x12
C150x12
C150x12
METAL DECK
0505FRAMING ONTO EXISTING STEEL JOISTS AND DECK
2-L64x64x6.4
TO ADJACENT
BOTTOM PANEL
POINTS
L152x102x9.5 LLV
x150LG.
DESIGN FOR FORCE
SHOWN ON PLAN
L152x102x9.5 LLV
HORIZONTAL LEG NOTCHED
TO FIT FLUTES OF DECK SPAN
OVER 2 PANEL POINTS, MIN.
REFER TO PLAN FOR
FRAMING MEMBERS, TYP.
(TWO OPTIONS SHOWN)
DETAIL AT EXISTING JOIST
DETAIL AT EXISTING DECK
APPLIED
LOAD
BENT PLATE
200x100x1.91
SCREWED TO u/s
OF EXISTING DECK
AT 300 o/c, TYP.
EDGE OF
OPENING
BENT PLATE
200x100x1.91
SCREWED TO u/s
OF EXISTING DECK
AT 300 o/c, TYP.
100
MIN.TYP.
0512ROOF ANCHORS ON STEEL FRAMING
NOTES:
1. REFER TO ARCHITECTURAL DRAWINGS FOR QUANTITY AND LOCATIONS.
2. SEE ARCHITECTURAL DRAWINGS FOR THERMAL BREAK. CONNECT FOR FULL CAPACITY.
3. IN EXISTING STRUCTURES, LOCATE ROOF ANCHORS BETWEEN JOISTS OR BEAMS AND SUPPORT
ON HSS FRAMING AS SHOWN IN LOWER DETAIL.
4. STRUCTURAL STEEL OUTSIDE OF BUILDING ENVELOPE TO BE H.D. GALV.
22 kN ULTIMATE LOAD
ANY DIRECTION
700 M
AX
2500 o/c MAX.
ROOF ANCHOR ASSEMBLY
BY OTHERS TYP.
OPTIONAL THERMAL BREAK,
REFER TO NOTE 2 TYP.
LINE OF ROOFING
FOR CONTEXT ONLY
C150x12 OR AS
NOTED ON PLAN.
CONNECT FOR
Vf = 10 kN
Tf = 22 kNCONNECT FOR
Mf = 15.5 kN.m
Vf = 12 kN
Tf = 22 kN
16 STIFFENER PL.
EA.SIDE TYP.
b ≥ 133
22 kN ULTIMATE LOAD
ANY DIRECTION
HSS 152x152x8.0 FRAME
BETWEEN ROOF BEAMS
OR JOISTS
CONNECT EA. END FOR
Vf = 12 kN
Tf = 22 kN
Tf = 15.4 kN.m (TORSION)
700 M
AX
COPE ENDS AS
REQUIRED
NOTE: FOR BEAMS SUPPORTING
ANCHORS WITH b < 133 INCREASE
TO BEAM FROM NEXT SIZE GROUP
WITH EQUAL OR GREATER VALUE
FOR Ix (EG. W200x22 → W200X27)
2500 o/c MAX.
90 OD MIN.
2017-12-22
LENGTH OF WELD TYP.
25mm MIN. TOTAL
5
5
WEB
t
b
d
txbdL3L2JOIST MARK
EACH END TYP.
300 CONT. WELD5
5
75-300
75-300
75-5005
75-5005
EACH END TYP.
300 CONT. WELD
SEE TABLE BELOW
FOR ROD DIAMETER
SEE TABLE BELOW
FOR PLATE SIZE
SEE TABLE BELOW FOR
WEB REINFORCING
CONTRACTOR NOTE: DO WELDING IN SUCH A WAY AS TO AVOID LOCKING IN
STRESSES DUE TO THERMAL EXPANSION OF JOIST REINFORCING MATERIALS.
IF REQUIRED, SPLICES IN CHORD REINFORCING MUST BE MADE WITH FULL
PENETRATION WELDS.
EQ. EQ.
L3 = EXTENT OF REQUIRED
FLEXURAL REINFORCING
CL INSTALL WEB
REINFORCING FROM
ALTERNATING SIDES,
TYP.
L2 = EXTENT OF REQUIRED
SHEAR REINFORCING AT RIGHT END
L2 = EXTENT OF REQUIRED
SHEAR REINF. AT LEFT END REINFORCE EACH WEB
MEMBER TO THE FIRST
PANEL POINT BEYOND
THE EXTENT INDICATED
OPEN WEB STEEL JOIST REINFORCING 0507
t
L1
Ø
NOTE:
1. PROVIDE WEB DIMENSIONS AND LAYOUT
OF EACH MEMBER IF WEB MEMBERS
VARY IN SIZE.
2. NOTIFY CONSULTANT IF JOIST HAS
MECHANICAL OPENINGS OR HAS BEEN
PREVIOUSLY REINFORCED.
3. PROVIDE DIMENSIONS FOR EACH JOIST IF
JOISTS SHOWN ON PLAN VARY.
CL
REQUIRED OWSJ DIMENSIONS
X1 X2, TYP. X1
Y3, TYP.Y2 Y2
H
WEB MEMBER
ROD:
ANGLE:
OTHER: NOTIFY CONSULTANT
Ø
L1
L2
t
TOP CHORD
BOTTOM CHORD
WEB MEMBER, TYP.
t
L2
L1
TOP CHORD
BACK TO BACK ANGLE:
OTHER: NOTIFY CONSULTANT
BOTTOM CHORD
BACK TO BACK ANGLE:
OTHER: NOTIFY CONSULTANT
L1
L2
t
L
H
L
X1
X2
Y1
Y2
s
s
L2
JOIST DIMENSION
WEB DIMENSION
TOP CHORD DIMENSION
s
t
L2
L1
L1
L2
t
s
BOTTOM CHORD DIMENSION
Y1 Y1
Y3
0507A
2017-12-22
NEW W250x58
NE
W W
310x97
NE
W W
31
0x97
EXISTING 7" SLAB
EX
IST
ING
7"
SL
AB
EXIST C8
3 E
XIS
TIN
G 1
8"
OW
SJs
INF
IL
SEE CASH ALLOWANCES FOR
PROVISIONS TO STRENGTHEN
CROFT ROOF TO ACCOMODATE
SUSPENDED FEATURE BY OWNER
NEW W250x28 LINTEL
INSTALL NEW LINTELS
AND DEMOLISH
EXISTING MASONRY
WALLS
MIN MASONRY PIER
SIZE TO REMAIN TO
BE 1200x300.
EXISTING SLAB
SAW-TOOTHED INTO
EXISTING MASONRY TO
REMAIN
NEW SLAB TO MATCH THICKNESS OF
ADJACENT EXISTING SLAB. R/W 15@200 BEW.
SAWTOOTH INTO EXISTING MASONRY WITH
100x300 POCKETS SPACED AT 600 c/c. ADD
DOWELS INTO EXISTING SLAB AS PER DETAIL
FOR SHEAR TRANSFER.
EXPOSED CONCRETE FINISH AS PER ARCH
SAWCUT AND REMOVE
CANT PORTION OF
EXISTING SLAB.
ROUGHEN EXISTING
SURFACE.
EXISTING 7" SLAB
EXISTING
CONCRETE BEAM
SUPPORTING STAIR
EXISTING EDGE OF
STAIR LANDING
RE-WORK BOTTOM OF
EXISTING OWSJ TO MEET
MINIMUM HEADROOM
REQUIREMENTS
04
S207
REFER TO ARCH FOR EXPOSED
CONCRETE LOCATIONS AND FINISH.
AEC TYPE AS PER SPEC.
05
S207
NEW W250x28
NEW W250x28
NEW SERVERY CEILING
BELOW. STUDS AND
JOISTS TO BE DESIGNED
BY OTHERS. MINIMUM
DESIGN LOAD FOR
CEILING TO BE 2.40 kPa.
REMOVE EXISTING BACK OF
CHIMNEY BELOW SECOND FLOOR.
SUPPORT EXISTING CHIMNEY
ABOVE SECOND FLOOR ON W250
TRANSFER BEAMS.
CONNECT
EXIST
C8 TO
NEW
W310
01
S208
01
S208 SIM
02
S208
03
S208
04
S208
06
S208
NEW W250x49
LINTEL
WALLS
REMOVED
BELOW
WALLS REMOVED BELOW
NEW AV CABINET CEILING
BELOW. STUDS AND JOISTS
TO BE DESIGNED BY
OTHERS. MINIMUM DESIGN
LOAD FOR CEILING TO BE
2.40 kPa.
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
08
S208
09
S208
400
550
550x400x300 DEEP
CONCRETE BEARING PAD
FULL WIDTH OF EXIST.
WALL
EX
IST
ING
7"
SLA
B
EX
IST
ING
7"
SLA
B
NE
W W
20
0x15
EXISTING 7" TIERED SLAB
NEW STAIR
RA
MP
DO
WN
RA
MP
DO
WN
RAMP DOWN
SLAB INFILL TYPE S1
EXISTING 300 OWSJ. SHORE
OWSJ TO INSTALL NEW STEEL
BEAM. RE-WORK ENDS AND
SUPPLY NEW JOIST SHOES AT
NEW STEEL BEAM.
REINFORCE EXISTING STEEL BEAM AS PER DETAILS
SLAB INFILL TYPE S1
REFER TO ARCH FOR EXTENTS OF
INFILL
NEW LINTELS OVER NEW AND
EXISTING OPENING BELOW.
SLAB INFILL TYPE S1
75 THICK CONCRETE R/W WWF 152x152
MW 25.8 x MW 25.8, MIN 40 COVER OVER
WWF. SUPPORT NEW CONCRETE ON
RIGID INSULATION VOID FORM BELOW.
EXPOSED CONCRETE FINISH AS PER
ARCH
SLAB INFILL TYPE S1
01
S207
REFER TO ARCH FOR EXPOSED
CONCRETE LOCATIONS AND FINISH.
AEC TYPE AS PER SPEC.
03
S207
87 CONCRETE ON 38 STEEL FORM DECK TO
SPAN FROM SILL TO RAMP. MIN THICKNESS
OF FORM DECK TO BE 0.96 mm.
METAL GRATING, DESIGN BY OTHERS. TYP
BOTH SIDES. CAST-IN CONNECTIONS TO SIDE
FACE OF CONCRETE TO BE BY OTHERS.
STEEL SUPPORT ANGLES
FASTENED TO EXISTING
MASONRY FOR FHC SUPPORT
NEW SERVERY STUD
WALLS
HANDRAILS BY OTHERS.
FASTEN TO CONCRETE
BELOW.
RE-WORK SHOES
OF EXISTING OWSJ
TO BEAR ON NEW
STEEL BEAM
EX
IST
ING
6"
SLA
B
06
S207
TRENCH THROUGH EXISTING
CONCRETE SLAB IN THE
DIRECTION OF THE SPAN. REFER
TO SECTIONS FOR REQUIRED
DEPTH OF TRENCH
NEW OPENING
SLAB INFILL TYPE S1
OVER STAIRS BELOW
03
S207
SIM
02
S207
PORTION OF EXISTING
MASONRY WALL TO REMAIN
AS PIER TO SUPPORT NEW
BEAM ABOVE
01
S201
02
S20104
S201
05
S201
07
S207
03
S201125 CONCRETE SLAB ON
76 FORM DECK (0.91 mm)
05A
S201
NEW CONCRETE CURB ON
EXISTING STEEL BEAM
BELOW. REINFORCE STEEL
BEAM AS PER DETAILS
INFILL EXISTING OPENINGS
WITH 240 CMU. ADD 1-20M
VERTICAL IN EACH CELL.
GROUT ALL CELLS SOLID.
05
S208
NOTE:
IN ALL AREAS WHERE HOUSEKEEPING PADS
ARE TO BE REMOVED AND REPLACED, THE
FOLLOWING NOTES APPLY:
DEMOLISH EXISTING HOUSEKEEPING PAD.
ROUGHEN SURFACE BENEATH NEW
HOUSEKEEPING PAD. APPLY BONDING
AGENT TO SURFACE OF EXISTING
CONCRETE. REPLACE WITH NEW 100 THICK
CONCRETE HOUSEKEEPING PAD. REFER TO
ARCH AND MECH FOR DIMENSIONS AND
PROJECTIONS. REINFORCE WITH 10M @ 300
TEW. PATCH AND MAKE GOOD ANY AREAS
WHERE CONCRETE REMOVED AND NOT
REPLACED WITH CONCRETE ABOVE.
NEW AV CABINET
STUD WALLS
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
01A
S201
NEW OPENING
EXTERIOR STAIR TO BE 100 THICK
CONCRETE R/W WWF 102x102 MW
25.8 x MW 25.8, MIN 60 COVER
OVER WWF. SUPPORT NEW
CONCRETE ON RIGID INSULATION
VOID FORM BELOW. EXPOSED
CONCRETE FINISH AS PER ARCH
REMOVE EXISTING SLAB FOR M&E
INSTALLATION BELOW, REINSTATE WITH
76 CONC. ON 76 COMPOSITE METAL
DECK (1.21 mm). R/W 10M@300 IN DECK
FLUTES, 10M@400 PERP. 10M@400
DOWELS IN TOP PERPENDICULAR TO
SUPPORTS, OR REINSTATE EXISTING.
03
S208
SIM
03
S208
SIM
REMOVE EXISTING SLAB FOR
M&E INSTALLATION BELOW,
REINSTATE WITH 76 CONC. ON
76 COMPOSITE METAL DECK (1.21
mm). R/W 10M@300 IN DECK
FLUTES, 10M@400 PERP.
10M@400 DOWELS IN TOP
PERPENDICULAR TO SUPPORTS,
OR REINSTATE EXISTING.
LINTEL AS PER TYP. DET.
0402 FOR WALL OPENING
BELOW. WIDTH NOT TO
EXCEED WINDOW ABOVE.
LINTEL AS PER TYP. DET.
0402, WIDTH NOT TO
EXCEED SPACE BETWEEN
MASONRY COLUMNS
ABOVE
SUPPORT END OF DECK
ON EXIST. MASONRY AS
PER 05/S201
125 CONCRETE
SLAB ON 76 FORM
DECK (1.21 mm)
NEW W200x15
NEW C100x8
NEW L76x76x9.5
TRENCH THROUGH EXISTING
CONCRETE SLAB IN THE DIRECTION
OF THE SPAN. REFER TO SECTIONS
FOR REQUIRED DEPTH OF TRENCH.
REFER TO NOTES BELOW
REGARDING NEW
ELECTRICAL JUNCTION
BOXES
NOTE:
FOR ELECTRICAL JUNCTION BOXES IN
CORRDIOR 179, A MAXIMUM OF ONE (1)
BRICK MAY BE REMOVED TO FACILITATE
INSTALLATION OF THE JUNCTION BOX.
ANY CORING, ADDITIONAL BRICK
REMOVAL, ETC. TO BE REVIEWED BY
THE STRUCTURAL ENGINEER.
COORDINATE WORK WITH THE
ARCHITECTURAL AND ELECTRICAL
DRAWINGS.
01
S101
CROFT - GROUND FLOOR FRAMING PLAN1:100
02
S101
CROFT - SECOND FLOOR FRAMING PLAN1:100
KEYPLANN.T.S.
2017-12-22
PIT B
ELOW
1
1 1
1
1 1
2
2 2
3
2 23
3
3 3
3
3
300 MAT SLAB. R/W 15@300
T+B EW. STEP DOWN
ACCORDING TO SECTION TO
MEET U/S SUMP PIT.
1 3
THIS AREA
ALREADY
UNDERPINNINED
SD
F
SD
F
EXTENT OF UNDERPINNING AS
SHOWN. UNDERPINNG DEPTH IS
APPROXIMATELY 2000, TO BE
INSTALLED IN 2 LIFTS.
UNDERPINNING TO BE DEEPER
ADJACENT TO SUMP PIT.
REMOVE SLAB ON GRADE
IN THIS AREA FOR
UNDERPINNING WORK
AND REINSTATE WITH
NEW SLAB ON GRADE
PRE-CAST SUMP PIT BY OTHERS.
REFER TO ARCH AND MECH FOR
LOCATION AND DEPTH. STEP DOWN
FOOTINGS TO U/S SUMP PIT
SDF
NOTE 'A'
SW1
SW3
SW
2
SW
2
01
S202
POUR NEW CONCRETE WALLS
AGAINST UNDERPINNING AND
EXISTING MASONRY
NOTE:
PROVIDE TEMPORARY
SHORING. REFER TO
SECTION
NOTE: FOR ALL NEW CORES THROUGH
EXISTING MASONRY, MAINTAIN MIN 300mm
CLEAR DISTANCE BETWEEN ALL EXISTING
OPENINGS, ARCHS, LINTELS, SLEEVES, ETC.
NOTIFY ENGINEER PRIOR TO CORING IF THIS
CLEAR DISTANCE CANNOT BE MAINTAINED.
EXISTING 150 CONCRETE SLABS TO
REMAIN. BEAR EXISTING SLABS ON NEW
WALLS BELOW.
NOTE 'A':
EXISTING OPENING THROUGH
MASONRY WALL ABOVE AND BELOW.
WIDTH OF OPENING BELOW TO BE
SITE VERIFIED. EXTEND WIDTH OF
OPENING BELOW WITH VERTICAL CUT
NO WIDER THAN WIDTH OF EXISTING
OPENING ABOVE.
NOTE 'A'
SW1
SW3
SW
2
SW
2
NEW OPENING IN
EXIST SLAB. REFER
TO NOTE ABOVE
REGARDING
CUTTING
CONCRETE
01
S202
02
S202
OPENING IN EXISTING WALL FOR
NEW PIPES, LAYOUT LOCATIONS
FOR STRUCTURAL CONSULTANT
REVIEW BEFORE CUTTING.
SIMILAR BETWEEN GRID LINES 4-5.
W150x18W150x18
REMOVE EXISTING
ROOF BELOW
SW1
SW3
SW
2SW
2
W150x18
OPEN
01
S203
02
S203
EXISTING LINTEL BELOW
SECOND LEVEL
01
S203
SIM
03
S203
W150x18
04
S203
PENETRATIONS THROUGH
SLAB. REINFORCE AS PER
TYPICAL DETAILS
04
S203
SIM
05
S203
62 CONCRETE ON 38 METAL DECK.
R/W 152x152 MW18.7 x MW18.7
W150x18
W150x18W150x22
W150x22
OPEN
06
S207
EX
IST
ING
5"
SL
AB
EX
IST
ING
5"
SLA
B
EXISTING BM 60"x16"
EXISTING BM 60"x16"
DO NOT CUT OR DAMAGE
EXISTING CONCRETE BEAM
BELOW. MAINTAIN MINIMUM
100 CLEAR DISTANCE
BETWEEN EDGE OF BEAM AND
ANY CONCRETE CUTTING
SW1
SW3S
W2
SW
2
OP
EN
01
S203
02
S203
01
S203
03
S203 04 A
S203
04
S203
TRENCH THROUGH EXISTING
CONCRETE SLAB. REFER TO
SECTIONS FOR REQUIRED DEPTH
OF TRENCH
SIM
SIM
SIM SIM
SIM
03
S203
SIMW150x2262 CONCRETE ON 38 METAL DECK.
R/W 152x152 MW18.7 x MW18.7.
MIN DECK THICKNESS = 0.91mm
190 MASONRY WALL
ABOVE TO SUPPORT LOW
ROOF FRAMING
REMOVE SLAB BETWEEN EX. BEAMS
FOR M&E INSTALLATION. REPLACE
WITH 125 CONC. ON 76 METAL DECK
(1.21 mm), R/W 15M@400 BLL,
10M@400 BUL. DOWEL BOTTOM
BARS INTO BEAM WITH 15M@400 IN
HILTI HY-200, MIN. EMB. 145 mm.
SUPPORT DECK ON L76x76x6.4
ANCHORED TO BEAM WITH 12 mm
DIA. THREADED ROD IN HILTI
HY-200, MIN. EMB. 114 mm.
02
S204
AT THIS END, PLATE
CONNECTION TO
EXISTING MASONRY TO
BE 400 WIDE
OVERHEAD HSS FOR COILING DOOR.
PROVIDE CONNECTIONS TO
EXISTING MASONRY EACH END
SIMILAR TO 07/S205. JAMB STEEL,
HSS, CONNECTIONS TO STRUCTURE
AND EXISTING MASONRY BY
OTHERS. COORDINATE WITH MISC.
METALS FABRICATOR AND DOOR
SUPPLIER
LINTEL
OVER
NEW
OPENING
W200X36 HIGH ROOF BEAM. CONNECT
ROOF ANCHOR TO TOP FLANGE AND
PROVIDE STIFFENERS BOTH SIDES AS
PER TYPICAL DETAIL
38 METAL ROOF DECK
MIN THICKNESS 1.52mm. SUPPLY
SINGLE SHEET FOR FULL
LENGTH AND WIDTH.
MAX UNFACTORED SNOW LOAD
ON LOW ROOF = 14.6 kPa
38 METAL ROOF DECK
MIN THICKNESS 0.91mm.
MAX UNFACTORED SNOW LOAD
ON MID ROOF = 6.6 kPa
38 METAL ROOF DECK
MASONRY SHEAR WALLS BELOW
HIGH
ROO
F
MID
ROOF
LOW ROOF
01
S204
ROOF ANCHOR, TYP
02
S204
W200x36 HIGH ROOF BEAM. PROVIDE TOP
AND BOTTOM FLANGE BRACING TO W200
HIGH ROOF BEAMS
W150x37 MID ROOF BEAM. PROVIDE TOP
AND BOTTOM FLANGE BRACING TO W150
MID ROOF BEAMS
W150x37 MID ROOF BEAM. CONNECT
ROOF ANCHOR TO TOP FLANGE AND
PROVIDE STIFFENERS BOTH SIDES AS
PER TYPICAL DETAIL
W150x22
W150x22
W150x18
W150x18, TYP FOR (3) LOW ROOF BEAMS
W150x37, TYP FOR (3) LOW ROOF BEAMS
CONNECTED TO ROOF ANCHOR.
03
S204
ROOF
190 CMU
15M @ 800 V
2-3.66Ø @ 400 H
SW1
LEVEL 3
190 CMU
15M @ 800 V
2-3.66Ø @ 400 H
190 CMU
15M V EACH CELL
2-3.66Ø @ 400 H
200 CONC
15M @ 400 VEF
10M @ 400 HEF
LEVEL 2
LEVEL 1
BASEMENT
FDN
190 CMU
15M @ 800 V
2-3.66Ø @ 400 H
SW2
190 CMU
15M @ 800 V
2-3.66Ø @ 400 H
190 CMU
15M @ 400 V
2-3.66Ø @ 400 H
200 CONC
15M @ 400 VEF
10M @ 400 HEF
ALL CELLS FULLY
GROUTED
ALL CELLS FULLY
GROUTED
ALL CELLS FULLY
GROUTED
ALL CELLS FULLY
GROUTED
ALL CELLS FULLY
GROUTED
ALL CELLS FULLY
GROUTED
190 CMU
15M V EACH CELL
2-3.66Ø @ 400 H
SW3
190 CMU
15M V EACH CELL
2-3.66Ø @ 400 H
190 CMU
15M V EACH CELL
2-3.66Ø @ 400 H
200 CONC
15M @ 400 VEF
10M @ 400 HEF
ALL CELLS FULLY
GROUTED
ALL CELLS FULLY
GROUTED
ALL CELLS FULLY
GROUTED
1-15M V
CORNER REINF.
4-15M V
10M @ 200 TIES
1-25M x 2500 INTO
CONCRETE
BELOW. MIN 900
INTO SW BELOW
1-15M V
1-20M V ABOVE
SHEAR WALL SCHEDULE NOTES:
1. REFER TO TYPICAL DETAILS FOR ALL INFORMATION NOT SHOWN HERE. WHERE
CONFLICTING INFORMATION OCCURS, THE MOST STRINGENT OF DETAILS SHALL APPLY.
2. DO NOT POUR A CONSTRUCTION/COLD JOINT AT THE BASEMENT LEVEL SLAB ON GRADE.
ALL REBAR TO BE CONTINUOUS FROM THE FOUNDATION TO THE U/S OF THE LEVEL 1
SLAB, OR PROVIDE STAGGERED SPLICES AS REQUIRED. NO MORE THAN 50% OF
REINFORCING TO BE SPLICED AT ANY ONE ELEVATION.
3. PROVIDE DOWELS BETWEEN FOUNDATION TO CONCRETE WALLS MATCHING VERTICAL
SPACING OF REBAR. PROVIDE MIN 2 STIRRUPS IN FOUNDATION AT THE CORNER
VERTICAL REINFORCING DOWELS.
4. PROVIDE DOWELS BETWEEN THE CONCRETE AND MASONRY WALL INTERFACE. AT
INTERSECTION OF EXISTING SLAB, PROVIDE EITHER A) PRE-DRILLED DOWELS THROUGH
THE SLAB AND EMBEDDED INTO THE CONCRETE WALLS BELOW, OR B) POST-INSTALLED
DOWELS INTO THE CONCRETE WALL BELOW USING EPOXY GROUT HILTI HY-200. ALL
DOWELS TO BE FULLY DEVELOPED AS PER THE TYPICAL DETAILS.
5. DO NOT PROVIDE CONSTRUCTION/EXPANSION JOINTS IN MASONRY ELEVATOR SHAFT
WALLS.
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
01
S102
ELEVATOR - FOUNDATION FRAMING PLAN1:100
02
S102
ELEVATOR - FIRST FLOOR FRAMING PLAN1:100
03
S102
ELEVATOR - SECOND FLOOR FRAMING PLAN1:100
05
S102
ELEVATOR - ROOF FRAMING PLAN1:100
04
S102
ELEVATOR - THIRD FLOOR FRAMING PLAN1:100
KEYPLANN.T.S.
06
S102
ELEVATOR - SHEAR WALL SCHEDULE
ELEVATOR FRAMING NOTES
1:100
1. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIOS OF FLOOR ASSEMBLY.
2. WHERE CROSSED AND NOTED THE LOCAL DATUM FOR RAISED OR LOWERED AREAS
ARE GIVEN RELATIVE TO THE GIVEN DATUM.
3. TOP OF CONCRETE ON METAL DECK IS 20mm BELOW THE FINISHED FLOOR ELEVATION
UNLESS NOTED.
4. TOP OF STEEL BEAMS SUPPORTING THE CONCRETE ON METAL DECK ARE 100mm
BELOW THE FINISHED FLOOR ELEVATION UNLESS OTHERWISE NOTED.
5. SUPERIMPOSED LOADS USED IN THE DESIGN:
LIVE LOAD
ELEVATOR LOBBY 4.8 kPa
ROOF SNOW LOAD 1.29 kPa + ASL AS NOTED
DEAD LOADS
ELEVATOR LOBBY: ROOF:
PARTITIONS 1.0 kPa ROOFING 0.40 kPa
FLOOR FINISH 0.25 kPa SUSPENDED 0.35 kPa
SUSPENDED 0.35 kPa TOTAL 0.75 kPa
TOTAL 1.60 kPa
6. ASSUMED SELF WEIGHT OF STRUCTURE USED IN THE DESIGN:
CONCRETE ON METAL DECK1.90 kPa
METAL DECK 0.15 kPa
STRUCTURAL STEEL 0.40 kPa
7. REFER TO DRAWING S001 FOR GENERAL NOTES.
8. REFER TO DRAWING S002-S006 FOR TYPICAL DETAILS.
2017-12-22
NEW W250x49 NEW W360x45
NEW W250x49
NE
W W
410
x54
NE
W W
410
x67
NE
W W
410
x46
EXISTING CONCRETE ON METAL PAN
EX
IST
ING
16"
OW
SJ @
24"
c/c
EX
IST
ING
CO
NC
RE
TE
ON
ME
TA
L P
AN
EXISTING 14" OWSJ @ 24" c/c
EX
IST
ING
CO
NC
RE
TE
ON
ME
TA
L P
AN
EXISTING 10" OWSJ @ 24" c/c
EX
IST
ING
5"
SL
AB
NE
W W
410
x54
NE
W W
410
x54
NEW STEEL BEAMS TO SUPPORT FEATURE
STAIR ABOVE. FABRICATOR TO PROVIDE
REACTION LOADS PRIOR TO ERECTION
FEATURE STAIR BY
OTHERS. DESIGN FOR
LOADS AND GUARD
LOADS ACCORDING TO
OBC2012
MIL
LW
OR
K
MIL
LW
OR
K
MIL
LW
OR
K
MIL
LW
OR
K
MIL
LW
OR
K
MIL
LW
OR
K
MIL
LW
OR
K
MIL
LW
OR
K
MIL
LW
OR
K
MIL
LW
OR
K
CA CA CA CA
CA
CACACACACA
NEW W360x45
ADD LINE OF BRIDGING TO
SUPPORT TOP FLANGE OF NEW
WIDE FLANGE BEAMS. ADD
BRIDGING LINE AT EACH
QUARTER POINT AND AT EACH
CONNECTION TO COLUMNS
ABOVE. BRIDGING TO CONNECT
TO MINIMUM 2 JOISTS ON EITHER
SIDE OF THE NEW WIDE FLANGE
BEAMS. TYP FOR ALL NEW BEAMS
ON SECOND LEVEL
NOTES:
1. VERIFY EXACT LOCATIONS OF OWSJ FRAMING PRIOR TO FABRICATION
OF BEAMS. IN THE EVENT OF INTERFERENCE BETWEEN EXISTING OWSJ,
ALLOW FOR EITHER:
A) TEMPORARY SHORING OF ADJACENT OWSJ. REMOVAL OF
INTERFERRING OWSJ, REPLACE EXISTING OWSJ WITH SIMILAR
CONNECTIONS EITHER END. INSTALL NEW BEAM IN CORRECT
LOCATION; OR,
B) INSTALL (2) WIDE FLANGE BEAMS EITHER SIDE OF
INTERFERRING OWSJ. REMOVE INTERFERRING OWSJ AND ADD
NEW STEEL PLATES/ANGLES TO TRANSFER LOAD FROM COLUMN
ABOVE INTO NEW BEAMS.
NOTIFY ENGINEER OF ANY INTERFERENCES AND ALLOW FOR RE-DESIGN
OF BEAMS IN EVENT OF INTERFERENCE.
2. ALLOW FOR REMOVAL AND REINSTATEMENT OF EXISTING OWSJ
BRIDGING WHERE INTERFERRING WITH NEW WORK. WHERE AN
EXISTING OWSJ WOULD HAVE BRIDGING REMOVED ON BOTH SIDES,
ALLOW FOR TEMPORARY SHORING OF THE OWSJ UNTIL BRIDGING IS
REPLACED.
3. REMOVE AND REPLACE ALL MECHANICAL AND ELECTRICAL
INTERFERENCES. REFER TO ARCH, MECH, AND ELEC DRAWINGS FOR
INFORMATION.
MIL
LW
OR
K
UNDER AREAS OF MILLWORK
ABOVE, LIVE LOAD = 7.20 kPa.
CONCTRACTOR TO
SITE-MEASURE EXIST OWSJ
DIMENSIONS AND REPORT
DIMENSIONS TO ENGINEER.
REFER TO TYPICAL DETAIL
0507A FOR REQUIRED
DIMENSIONS. TYP FOR ALL
EXIST OWSJ UNDER NEW
MILLWORK AREAS ABOVE.
01
S205
01
S205
SIM
01
S205
SIM
01
S205
SIM
01
S205
SIM
01
S205
SIM
01
S205
SIM
01
S205
SIM
01
S205
SIM
02
S205
03
S205
BP1
BP1
MARKWIDTH x DEPTH
x THICKNESS
04
S205
ANCHORAGE
BP2
BP2
BP1 350 x 450 x 15 4-12Ø HILTI KWIK BOLT 3
BP2 250 x 250 x 10 4-12Ø HILTI KWIK BOLT 3
BP3 300 x 300 x 15 4-12Ø HILTI KWIK BOLT 3
BP1
BP1
BP3
BP3 400 x 450 x 15 4-12Ø HILTI KWIK BOLT 3
BEARING PLATE SCHEDULE
NOTES:
1. WIDTH IS DIRECTION PARALLEL WITH
THE EXISTING MASONRY WALLS BELOW.
2, REFER TO SECTIONS FOR NOTES ON
EXISTING CONDITIONS
BP3BP4 BP4
BP3
01
S205
SIM
BP3 BP3 BP3BP3
NOTE: SECTIONS TYP FOR
ALL BEARING PLATES ON
EXISTING MASONRY WALLS
NOTE:
LONG-SPAN STEEL BEAMS
SUPPORTING COLUMNS ABOVE
MAY REQUIRE SPLICING. TO BE
DETERMINED BY CONTRACTOR
BASED ON SITE CONDITIONS
AND ACCESS. ALL SPLICES TO
FULLY DEVELOP MOMENT AND
SHEAR CAPACITY OF BEAM.
CHIP AND REMOVE 20mm CONCRETE FROM
CONCRETE ON PAN WITHIN THIS REGION.
REPLACE WITH 10mm THIN-SET GROUT AND 10
THICK STEEL PLATE, PROVIDED IN SINGLE PLATE
DIRECTLY BELOW FINISHED FLOOR. FEATURE
STAIR FABRICATOR TO FASTEN/WELD DIRECTLY
TO THIS PLATE
ADD 4-L102x102x4.8 KICKERS FROM
BOTTOM FLANGE OF NEW STEEL BEAMS
UP TO SUPPORT TOP CHORD OF
EXISTING OWSJ. INSTALL PRIOR TO
ERECTION OF NEW FEATURE STAIR
ABOVE. DESIGN FOR Tf=Cf=15 kN.
07
S206
07
S206
SIM
MAX. 38 mm
DEEP TRENCH,
CUT INTO EXIST.
SLAB.
06
S207
500
MA
X.
06
S207
TRENCH THROUGH EXISTING
CONCRETE SLAB IN THE
DIRECTION OF THE SPAN.
REFER TO SECTIONS FOR
REQUIRED DEPTH OF
TRENCH. SIM. AT ENTRANCE
TO WEST HALL.
01
S103
LIBRARY - SECOND FLOOR FRAMING PLAN1:50
KEYPLANN.T.S.
SECOND FLOOR FRAMING NOTES
1:50
1. REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR ASSEMBLY ELEVATIONS.
2. WHERE CROSSED AND NOTED THE LOCAL DATUM FOR RAISED OR LOWERED
AREAS ARE GIVEN RELATIVE TO THE THIRD FLOOR DATUM.
3. TOP OF FINISHED FLOOR IS 20 mm BELOW THE FLOOR DATUM.
4. TOP OF STEEL BEAMS SUPPORTING THE SLAB ON METAL DECK ARE 100mm BELOW
THE FINISHED FLOOR UNLESS OTHERWISE NOTED.
5. WHERE NOTED, TOP OF BEAM IS GIVEN RELATIVE TO THE FINISHED FLOOR.
6. SUPERIMPOSED LOADS USED IN THE DESIGN:
LIVE LOAD 4.8 kPa EVERYWHERE
7.2 kPa UNDER MILLWORK AREAS AS NOTED
DEAD LOADS
PARTITIONS 1.0 kPa
FLOOR FINISH 0.25 kPa
SUSPENDED 0.35 kPa
TOTAL 1.60 kPa
7. ASSUMED SELF WEIGHT OF STRUCTURE USED IN THE DESIGN:
CONCRETE ON METAL DECK 1.90 kPa
STRUCTURAL STEEL 0.40 kPa
8. REFER TO DRAWING S001 FOR GENERAL NOTES.
9. REFER TO DRAWING S002-S006 FOR TYPICAL DETAILS.
2017-12-22
EXISTING 8" OWSJ @ 24" c/c TO REMAIN
EX
IST
ING
5"
CO
NC
RE
TE
SLA
B
EX
IST
ING
CO
NC
RE
TE
ON
ME
TA
L P
AN
TO
RE
MA
IN
EX
IST
ING
CO
NC
RE
TE
ON
ME
TA
L P
AN
AN
D E
XIS
TIN
G
OW
SJ T
O B
E R
EM
OV
ED
W150x30 CRANKED CRANKED W150x30
W150
x22
CANT
W150x13 (SLOPED)PA
PA
PA - HSS102x102x3.2
POST ABOVE TO SUPPORT
HIGH FRAMING, TYP
PA
W15
0x1
3
W15
0x1
3
W25
0x1
8
W150x13
W200x36
W150
x13
(S
LO
PE
D)
W200x19
W1
50x1
3
W1
50x18
W1
50x1
3
W150
x13
W150
x13
W150x13 (SLOPED)
W150
x13
(S
LO
PE
D)
W150x13
+84
+26
0
+260
±0
±0
W150x13
0
D1
STRUCTURAL FRAMING IN
THIS AREA SIMILAR TO STEEL
ON OTHER PLATFORM,
EXCEPT AS NOTED
W150
x22
W150
x22
W15
0x2
2
W150
x22
W150
x22
W150
x22
W150
x22
W150
x22
W150x18
W150
x18
W150x22W150x22W150x22W150x22
W150x22W150x22W150x22
W1
50x22
W1
50x22
W1
50x22
W1
50x22
W1
50x22
W1
50x22
W150x22
W150x22 W150x22
W150x22 W200x42 CANT
W150x30
W150
x13
W150
x30
W1
50x3
0
W1
50x3
0
W150x1
3
W150x13
W150x30
W1
50x13
W310
X39
W200
x18
W310
x39
CANT
OPEN TO BELOW
FEATURE STAIR, DESIGN BY
OTHERS
D1
D1
D1
W200x59
W200x31
CANT, TYP ALL EDGES
D1 - 62 CONCRETE ON 38 METAL DECK. R/W 152 x 152 x MW 18.7 x MW 18.7
D1
D1
WALLS ABOVE THIRD
LEVEL TO BE
DEMOLISHED SHOWN
DASHED HERE. REFER
TO ARCH FOR
EXTENTS. NEW LINTEL
ABOVE. ALLOW FOR
2-W250x58 w/ PL20 TOP
AND BOTTOM x FULL
WIDTH OF WALL. TO BE
VERIFIED ON SITE
DURING DEMOLITION.
NEW 75 THICK CONCRETE TOPPING OVER RIGID INSULATION
BELOW. REINFORCE TOPPING WITH 152 x 152 x MW 25.8 x MW 25.8.
LIVE LOAD REDUCED TO 2.4 kPa (OFFICE) IN CROSSED AREA
EXISTING 5"
CONCRETE
SLAB AND
STAIRS IN
THIS AREA
REMOVED.
W2
00x22
W20
0x1
5
STEEL JOISTS AND STUDS FOR GROUP STUDY AREA
TO BE DESIGNED BY OTHERS. MINIMUM DESIGN LOAD
FOR CEILING TO BE 2.40 kPa. TYP FOR BOTH GROUP
STUDY AREAS, BOTH PLATFORMS
GUARDRAIL DESIGN BY
OTHERS. FASTEN TO
CONCRETE TOPPING.
ALL COLUMNS BELOW U/N
TYPE C1 - W150x22
W150x30
W150x22
W15
0x1
3
W150x30
D2 - 150 CONCRETE ON
38 METAL 'FORM' DECK
REINFORCED WITH
15M@300 BEW. STEEL
BEAMS IN THIS AREA
TO RECEIVE
INTUMESCENT FIRE
PROTECTION. TYP FOR
ALL FRAMING IN
LANDING AREA
06
S205
05
S205
07
S205
06
S205
05
S205
07
S205
SIM SIM
SIM
W150
x13
08
S205
W2
00x22
09
S205
10
S205
STEEL BENT PLATE CONNECTION TYP
AT ALL CONNECTIONS TO EXISTING
MASONRY UNLESS NOTED.
01
S206
02
S206
W150x18
(SLOPED)
W150x18
(SLOPED)
W150
x18
W150x18
+6
37
+6
37
W15
0x2
2W
150x18
03
S206
04
S206
+220
+485
+485
NOTE: REFER TO ARCH FOR ALL AREAS
WITH HANDRAILS, GUARDRAILS. DESIGN
BY OTHERS FOR ALL SYSTEMS.
CONNECTION TO STRUCTURE BY
OTHERS FOR ALL SYSTEMS.
W150x13
04
S206SIM
OP
EN
W150
x18
OVERHEAD HSS FOR
COILING DOOR. PROVIDE
CONNECTIONS TO EXISTING
MASONRY EACH END
SIMILAR TO 07/S205. JAMB
STEEL, HSS, CONNECTIONS
TO STRUCTURE AND
EXISTING MASONRY BY
OTHERS. COORDINATE
WITH MISC. METALS
FABRICATOR AND DOOR
SUPPLIER
C2 BELOW
W150x30.
INTUMESCENT PAINT
ON COLUMN
W15
0x30
PL200x25
PL200x25
PL200x25
HB
HANGER BELOW
TYP (4) LOCATIONS
AT LANDING
11
S205
W150
x18
W150
x18
W15
0x18
12
S205
D3D3 - 62 CONCRETE ON 38 METAL DECK.
R/W 152 x 152 x MW18.7 x MW18.7. MAX
AGGREGATE SIZE IN CONCRETE
TOPPING TO BE 10mm. ADJUST MIX
DESIGN FOR SMALLER AGGREGATE.
USE THIS MIX ON LANDING ONLY
CANT DECK EDGES PAST
STRUCTURAL STEEL. DECK
FABRICATOR TO PROVIDE BENT
PLATE SUITABLE FOR CANTILEVER
LENGTH.
CANT
W150x18
150
W150x18 (LOW)
EDGE OF DECK AT MID LANDING
05-A
S205
07-A
S205LOW FRAMING AT
EXISTING WINDOW SILL.
REFER TO SECTION.
D2
06
S206
W200x15
W200x15
W200x15
W250x28
W150
x14
PROVIDE
BEARING PLATES
FOR ALL STEEL
BEAMS SIM TO
7/S205
THREAD NEW BEAMS
THROUGH MASONRY
WALLS BELOW AS
REQUIRED.
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
0
0
0
W200x46
W200x46
W200x46
NEW LINTEL OVER
EXTENDED FHC
OPENING IN EXISTING
WALL. REFER TO
03/S204 FOR SIMILAR
LINTEL.
01
S104
LIBRARY - THIRD FLOOR FRAMING PLAN1:50
THIRD FLOOR FRAMING NOTES
1:50
1. REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR ASSEMBLY ELEVATIONS.
2. WHERE CROSSED AND NOTED THE LOCAL DATUM FOR RAISED OR LOWERED AREAS
ARE GIVEN RELATIVE TO THE THIRD FLOOR DATUM.
3. TOP OF FINISHED FLOOR IS 20 mm BELOW THE FLOOR DATUM.
4. TOP OF STEEL BEAMS SUPPORTING THE SLAB ON METAL DECK ARE 100mm BELOW
THE FINISHED FLOOR UNLESS OTHERWISE NOTED.
5. WHERE NOTED, TOP OF BEAM IS GIVEN RELATIVE TO THE FINISHED FLOOR.
6. SUPERIMPOSED LOADS USED IN THE DESIGN:
LIVE LOAD 4.8 kPa EVERYWHERE, EXCEPT AS NOTED
2.4 kPa IN OFFICE AREAS AS NOTED
DEAD LOADS
PARTITIONS 1.0 kPa
FLOOR FINISH 0.25 kPa
SUSPENDED 0.35 kPa
TOTAL 1.60 kPa
7. ASSUMED SELF WEIGHT OF STRUCTURE USED IN THE DESIGN:
CONCRETE ON METAL DECK1.90 kPa
STRUCTURAL STEEL 0.40 kPa
8. REFER TO DRAWING S001 FOR GENERAL NOTES.
9. REFER TO DRAWING S002-S006 FOR TYPICAL DETAILS.
N.T.S.
KEYPLAN
2017-12-22
03
S105
GLAZING CONNECTION TO EXISTING STRUCTURE ABOVE
1:20
U/S CEILING
U/S EXISTING STRUCTURE
EXISTING STRUCTURE ABOVE
CONT L152x152x6.4. FASTEN TO
EXISTING STRUCTURE WITH
EXPANSION ANCHORS OR SIMILAR
DEPENDING ON STRUCTURE
ABOVE SPACED AT 400 c/c.
L102x102x6.4 KICKERS. SPACE
KICKERS SO THAT MINIMUM 2
SETS OF KICKERS SUPPORT
EACH GLAZED PARTITION AT
EACH END OF PARITION.
CONNECT FOR Tf=Cf=15 kN
MA
X 1
50
CONT L152x152x6.4 ACROSS TOP
OF GLAZED PARTITION. MAY BE
INTERRUPTED AND/OR SPLICED
PROVIDED THAT SINGLE ANGLE
IS PROVIDED ACROSS TOPS OF
GLAZING BETWEEN KICKERS.
GLAZED PARTITION BELOW.
CONNECTION TO STRUCTURE
ABOVE BY OTHERS NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
05
S105
TYP ALL GLAZING IN
ROOM 259
EXISTING 5" SLAB
SLAB INFILL TYPE S1
03
S204
SIM
NEW LINTELS
ABOVE NEW DOOR
OPENING
02
S105
ROOM 259
1:100
N.T.S.
KEYPLAN
01
S105
ROOM 171A
1:100
KEYPLAN
N.T.S.
2017-12-22
OPENING
BELOW
METAL GRATING AT LOWER
MECHANICAL LEVEL ABOVE
CONCRETE SLAB
EXISTING 10"
CONCRETE SLAB
AS REQUIRED, PROVIDE
TEMPORARY SHORING TO
EXISTING STEEL MEMBERS
ABOVE. SUPPORT
TEMPORARY SHORING ON
EXISTING CONCRETE SLAB. DO
NOT SUPPORT EXISTING
STEEL ABOVE FROM THE
LOWER MECHANICAL LEVEL
GRATING OR STEEL.
NEW OPENINGS THROUGH
EXISTING MASONRY FOR NEW
MECHANICAL SERVICES. REFE
TO MECH FOR LOCATIONS.
EX. ROOF
EX. ROOF
EX
. R
OO
F
EX. ROOF BEAM / TRUSSEX. ROOF BEAM / TRUSS
EX
. R
OO
F
ROOF STRUCTURE HIGH POINT
EXISTING BUILT-UP ROOF SLOPES.
REINSTATE AFTER COMPLETING
AHU WORK
REMOVE AND REINSTATE ROOF AND ROOF MEMBERS WITHIN
THIS AREA.
AFTER REMOVING ROOFING, CONFIRM LAYOUT OF STRUCTURAL
MEMBERS AND RECORD SIZE, SPACING, AND QUALITY OF
STRUCTURAL MEMBERS. NOTIFY ENGINEER WITH FINDINGS.
REINSTATE ALL STRCUTURAL MEMBERS AFTER INSTALLATION
OF AHU UNITS. REFER TO ARCH FOR REINSTATING ROOF.
ALLOW FOR NEW HATCH THROUGH
EXISTING ROOF. SIZE TBD BASED ON
EXISTING STRUCTURE. ALLOW FOR
REMOVAL OF (4) EXISTING ROOF BEAMS
AND REINFORCING OF ADJACENT ROOF
MEMBERS
SEPARATE PRICE ITEM:
PROVIDE ROOF ANCHOR FOR FALL ARREST SYSTEM.
COORDINATE WORK WITH ROOF HATCH AND WITH
ROOF HATCH REINFORCING. ALLOW FOR ADDITIONAL
REINFORCING OF MIN TRIPLEING EXISTING ROOF
MEMBERS WITH EQUIVALENT SIZE LVL MEMBERS, NEW
HEADER ACROSS EXISTING MEMBERS, STEEL FRAMING
BETWEEN MEMBERS AS PER TYPICAL DETAIL 0512, AND
TIE-IN TO ROOFING AND FLASHING SYSTEM. REFER TO
ARCH FOR LOCATION AND DETAILS.
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
EXISTING BRICK CORBELS ABOVE
EX
W1
2x6
.5W
F27 (
W3
10x3
9)
EX W12B14 (W310x21)
EX W12B14 (W310x21)
EXISTING AHU AND DUCTS TO BE
REPLACED. REFER TO MECH AND ARCH
FOR SIZE AND LOCATION. REFER TO
ROOF PLAN FOR APPROXIMATE AREA OF
ROOF REMOVAL REQUIRED TO
FACILITATE WORK.
NOTE:
NOT ALL EXISTING STEEL FRAMING REQUIRING REMOVAL DETAILED HERE. CONTRACTOR TO DETERMINE REQUIREMENTS OF
EXISTING STEEL REMOVAL BASED ON MEANS AND METHODS OF COMPLETING THE WORK.
WHERE REQUIRED, EXISTING STEEL BEAMS, CHANNELS, POSTS, HANGERS, GRATING, ETC. TO BE REMOVED TO ALLOW FOR
REMOVAL OF EXISTING AHU AND DUCTS AND FOR INSTALLATION OF NEW AHU AND DUCTS. STAGING AND PLANNING OF THE
WORK IS THE RESPONSIBILITY OF THE CONTRACTOR.
SUBMIT PLAN PRIOR TO DECONSTRUCTING STEEL DETAILING WHICH MEMBERS ARE TO BE REMOVED AND HOW REMAINING
STEEL MEMBERS WILL BE SUPPORTED TEMPORARILY. EXISTING HOIST BEAMS MAY BE USED TO LIFT AHU AND DUCTS INTO
PLACE AND TO FACILITATE REMOVAL OF THE EXISTING AHU AND DUCTS.
CONTRACTOR TO SUBMIT SHOP DRAWINGS WITH WEIGHTS OF MATERIALS TO BE HOISTED USING EXISTING STEEL MEMBERS.
PRIOR TO ERECTION, EXISTING HOIST BEAMS TO BE MEASURED AND INFORMATION SENT TO ENGINEER FOR REVIEW. INCLUDE
LIFITNG POINTS, TRAVEL ROUTES, ETC.
AFTER WORK HAS BEEN COMPLETED, REINSTATE EXISTING STEEL MEMBERS AND METAL GRATING. WHERE EXISTING WELDED
CONNECTIONS WERE REMOVED, REINSTATE WITH MATCHING WELDS OF SIMILAR TYPE AND QUALITY.
EXISTING WIDE-FLANGE BEAMS CAPABLE OF SUPPORTING
THE NEW AHU. SUBMIT AHU SHOP DRAWINGS SHOWING
SUPPORT REQUIREMENTS UP TO THE OVERHEAD BEAMS.
HANGERS AND CONNECTION TO EXISTING STEEL TO BE BY
STEEL FABRICATOR. WHERE POSSIBLE, SUPPORT
DIRECTLY FROM THE WIDE FLANGE BEAMS AND NOT FROM
THE CHANNELS. SUBMIT LOADS TO BE APPLIED TO
EXISTING STEEL CHANNELS AND ALLOW FOR
STRENGTHENING OF CHANNELS AS REQUIRED.
ALL SECONDARY FRAMING ARE EX 6C8.2
(C150x12) EXCEPT AS NOTED. NOT ALL
FRAMES SHOWN FOR CLARITY. REFER TO
EXISTING STRUCTURAL DRAWINGS FOR
INFORMATION.
EXISTING METAL GRATING BELOW AND EXISTING STEEL HANGERS
UP TO UPPER LEVEL OF STEEL FRAMING TO BE REMOVED AND
REPLACED TO FACILITATE AHU REPLACEMENT. REFER TO NOTES
BELOW REGARDING REPLACEMENT OF STEEL MEMBERS AND
CONNECTIONS.
NOTE:
REFER TO ARCH DOCMENTS FOR PLANS AND PHOTOGRAPHS OF
EXISTING FRAMING.
REFER TO MECH FOR SCOPE OF WORK AND EXISTING
MECHANICAL EQUIPMENT LOCATIONS.
02
S106
TOWER AHU - UPPER MECHANICAL FLOOR PLAN1:100
01
S106
TOWER AHU - LOWER MECHANICAL FLOOR PLAN1:100
03
S106
TOWER AHU - EXISTING ROOF PLAN1:100
N.T.S.
KEYPLAN
04
S106
TOWER AHU - EXISTING UPPER LEVEL FRAMINGN.T.S.
DRAWINGBLOCKTITLE 2017-12-22
GUARDAIL BY OTHERS.
CONNECTION TO
STRUCTURE BY
OTHERS
EXISTING MASONRY
EXISTING
CONCRETE SLABNEW PLATES, ANGLES, ETC. BY
OTHERS. FASTEN DIRECTLY TO
EXISTING CONCRETE SLAB BELOW.
CAST GUARDRAIL CONNECTIONS INTO
CONCRETE TOPPING BUT DO NOT RELY
UPON TOPPING FOR RIGID SUPPORT
RAMP, SLOPED
CONCRETE
TOPPING
01
S201
HANDRAIL AND CONCRETE TOPPING AT EXIT CORRIDOR1:20
02
S201
HANDRAIL AND CONCRETE TOPPING AT EXIT CORRIDOR1:20
EXISTING MASONRY BEYOND
EXISTING CONCRETE ON METAL
PAN
EXISTING OWSJ
EXISTING W200
EXISTING CONCRETE BEAM
EXISTING 7" CONCRETE SLAB
RAMP, SLOPED
CONCRETE TOPPING
BASEMENT LEVEL
TOP OF SLAB EL. 107.47
150 MIN
REMOVE EXISTING CONCRETE
STAIRS
MAKE GOOD CONCRETE AT
BASE OF EXISTING STAIR
SLAB THICKENING IN SLAB ON GRADE
UNDER NEW STAIRS. REFER TO TYPICAL
DETAILS. ADD 10M @ 300 x 600 LONG
DOWELS INTO EXISTING CONCRETE
SLAB ON GRADE. USE EPOXY GROUT HILTI HY-200 MIN EMBEDMENT 300
NEW CONCRETE STAIR. REFER TO
ARCH FOR DIMENSIONS OF TREADS
AND RISERS. MINIMUM THICKNESS 150.
REINFORCE WITH 15M @ 250 BEW
EXISTING CONCRETE WALL TO
REMAIN. BEND REBAR FROM
WALL INTO NEW STAIRS
BEND EXISTING REBAR INTO NEW
STAIR. REPLACE DAMAGED REBAR
WITH MATCHING SIZE AND SPACING
DOWELED INTO EXISTING CONCRETE
WALL BELOW.
EXISTING OWSJ TO REMAIN.
MAINTAIN FULL BEARING OF
OWSJ ON EXISTING CONCRETE
WALL DURING CONSTRUCTION
OR PROVIDE TEMPORARY
SHORING UNTIL NEW STAIR
COMPLETED. EXISTING JOIST
SHOES AT CONNECTION TO
EXISTING CONCRETE WALL TO
BE CAST IN TO NEW STAIR
CANT TOP OF STAIR PAST SUPPORT BELOW.
ADD 15M @ 250 TOP. MIN EXTENSION PAST
SUPPORT BELOW TO BE 600. EXTEND MIN 400
INTO SLAB ABOVE
LEAVE ROUGHENED SURFACE
EXISTING CONCRETE ON METAL PAN
FLOOR TO REMAIN. REMOVE
PORTIONS INTERFEREING WITH NEW
STAIR
04
S201
NEW CONCRETE STAIRS1:20
EXIT STAIR
FFE EL. 110.11
EXISTING EXIT
FFE EL. VARIES
FIRST FLOOR, EXIT CORRIDOR
TOP OF SLAB EL. VARIES
REINFORCE EXISTING 10LB19 WITH:
175x25 BOTTOM PLATE WELDED TO
BOTTOM FLANGE.
REINFORCE STEEL BEAM PRIOR TO
INSTALLING NEW W200x15 THAT
FRAMES INTO THIS BEAM
NEW W200 SUPPORTING
EXISTING OWSJ
FIRST FLOOR, WEST WING
TOP OF SLAB EL. 110.51
MIN 50
EXISTING CONCRETE ON METAL
PAN TO REMAIN
SAWCUT EXISTING CONCRETE
AT START OF NEW RAMP
PORTION OF EXISTING OWSJ TO REMAIN.
TEMPORARILY SUPPORT OWSJ DURING
CONSTRUCTION UNTIL ALL NEW STEEL
SUPPORTING OWSJ AND REINFORCING ON NEW
STEEL BEAMS IS INSTALLED. PROVIDE NEW JOIST
BEARING SHOE ON NEW STEEL BEAM. CUT OFF
AND REMOVE PORTIONS OF EXISTING OWSJ
INTERFERING WITH NEW WORK.
NEW
W200x15
CONT L152x102x7.9
(LLH) FOR CONCRETE
CLOSURE STRIP. MIN
GAP TO ALLOW
CONCRETE DOWN INTO
CAVITY TO BE MIN 50.
SLOPED CONCRETE RAMP
REMOVE EXISTING STAIRS
AND STEEL SUPPORTING
STAIRS
EXISTING STEEL BEAMS, OWSJ,
CONCRETE ON METAL PAN TO
REMAIN AT LOW LEVEL
06
S201
NEW CONCRETE RAMP1:20
EXISTING MASONRY WALL
IF LAST EXISTING WEB MEMBER IS MORE
THAN 50 FROM EDGE OF SHOE, ADD WEB
MEMBER ON EXIST OWSJ MATCHING SIZE
AS EXISTING WEB MEMBERS
EXIST OWSJ
TO REMAIN
EXISTING SLAB
ON GRADE
VOID
125
76
VOID
03
S201
EXISTING STEEL BEAM REINFORCING AT WEST HALL STAIR1:20
VOID
87 CONCRETE ON 38
METAL DECK (0.91 mm).
REINFORCE WITH
10@400 BEW
LAP MESH INTO
CONCRETE ON
DECK MIN 600
MASONITE BEARING PAD BELOW
STEEL DECK, BOND-BREAKER
APPLIED TO ALL EXISTING
SURFACE CONDITIONS
150 CONCRETE CURB. REINFORCE WITH 10M
@ 300 VERTICAL. DOWEL INTO SLAB BELOW
WITH HILTI HY-200 EPOXY GROUT. MIN
EMBEDMENT TO BE 100. DOWEL WITH SLAB
ABOVE WITH MATCHING REBAR.
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
SLOPED CONCRETE RAMP
VA
RIE
S
150 WIDE CONCRETE UPSTAND.
REINFORCE WITH 10M @ 400 V
DOWELS INTO CONCRETE SLABS
ABOVE. ADD CONT 2-10M H.
ROUGHEN CONCRETE SURFACE
BELOW AND APPLY BONDING
AGENT
SECONDARY CONCRETE POUR,
SLOPED TO SUIT RAMP SLOPE.
LEAVE ROUGHENED SURFACE
ABOVE AND BELOW
75 BEARING ON CONCRETE
EXISTING BEAMS,
OWSJ REMOVED
BELOWBENT PLATE AND CONNECTIONS
SIMILAR TO 7/S205 EXCEPT AS
NOTED. DIMENSIONS AS FOLLOWS
125
100VARIES
15M @ 400 x 400 LONG
WELDABLE REBAR
WELDED TO STEEL
PLATE
STEP TOP OF PLATE WITH SLOPED
CONCRETE RAMP. BEARING FOR CONCRETE
RAMP ON STEEL DECK TO BE CONTINUOUS.
FIELD WELD PLATES TOGETHER AT STEPS.
TOP OF PLATE TO BE FULLY ENCASED IN
CONCRETE AT ALL SECTIONS. MINIMUM
BEND NOTED 'VARIES' TO BE 50mm.
WELD BOTTOM PLATE AS NECESSARY,
OR PROVIDE SHIMS, OR PROVIDE
CUSTOM TAPERED BENT PLATE SHAPE
TO HAVE EVEN BEARING ACROSS FULL
WIDTH OF RAMP.
REINFORCE EXISTING 10WF21 WITH:
2-19Ø STEEL BARS WELDED TO TOP FLANGE AND WEB
200x19 BOTTOM PLATE WELDED TO BOTTOM FLANGE.
REINFORCE STEEL BEAM PRIOR TO POURING TOPPING AND NEW FLOOR ABOVE
EXISTING OWSJ
15M @ 400 BLL
10M @ 400 BUL
05
S201
NEW CONCRETE RAMP1:20
FIRESPRAY OR
INTUMESCENT PAINT ANGLE
SUPPORTING CONCRETE.
TYP FOR ALL AREAS IN WEST
HALL. REFER TO ARCH
VOID
125
125
76
76
REFER TO NOTES ON THIS
SHEET FOR STEEL PLATE
CONNECTION
EXIT STAIR
FFE EL. 110.11
EXISTING EXIT
FFE EL. VARIES
EXIT STAIR
FFE EL. 110.11
EXISTING EXIT
FFE EL. VARIES
05A
S201
NEW CONCRETE RAMP1:20
SIMILAR EXCEPT AS NOTED
VOID 76
150 CONCRETE CURB. REINFORCE
WITH 10M @ 300 VERTICAL. DOWEL
INTO SLAB BELOW WITH HILTI
HY-200 EPOXY GROUT. MIN
EMBEDMENT TO BE 100. DOWEL
WITH SLAB ABOVE WITH MATCHING REBAR.
150 CURB R/W 10M@300
EACH WAY. DOWEL INTO
SLAB BELOW WITH HILTI
HY-200 EPOXY GROUT. MIN
EMBEDMENT TO BE 100.
150 CURB R/W 10M@300 EACH
WAY. DOWEL INTO SLAB
BELOW WITH HILTI HY-200
EPOXY GROUT. MIN
EMBEDMENT TO BE 100.
LC
01A
S201
HANDRAIL AND CONCRETE TOPPING AT EXIT CORRIDOR1:20
L127x127x6.4 mm
EDGE ANGLE
GRATING BY OTHERS
MIRROR ABOUT
CENTER LINE
NICHE IN WALL FOR FHC
VOID
EXISTING STEEL BEAMS, OWSJ,
CONCRETE ON METAL PAN TO REMAIN AT
LOW LEVEL
EXISTING HERITAGE WALL SUPPORTING
STAIRS ABOVE TO BE SHORED ON EXIT
STAIR SIDE ONLY, FOR CONCRETE
PLACEMENT BELOW. REFER TO
PROTECTION DRAWINGS.
WELD L102x102x6.4 LEDGER TO
PL10 STIFFENERS @ 600 IN
BEAM BEYOND FOR NEW
SLOPING CONCRETE ON METAL
DECK
12
5
FIRST FLOOR, EXIT CORRIDOR
TOP OF SLAB EL. VARIES
EXISTING HERITAGE WALL
SUPPORTING STAIRS ABOVE TO
BE SHORED ON EXIT STAIR SIDE
ONLY, FOR CONCRETE
PLACEMENT BELOW. REFER TO
PROTECTION DRAWINGS.
EXISTING HERITAGE WALL SUPPORTING
STAIRS ABOVE TO BE SHORED ON EXIT
STAIR SIDE ONLY, FOR CONCRETE
PLACEMENT BELOW. REFER TO
PROTECTION DRAWINGS.
2017-12-22
EXISTING BASEMENT
FFE 107.43
EXISTING GRADE
EL. VARIES
ELEVATOR PIT TOP OF SLAB
EL. 105.73
01
S202
NEW UNDERPINNING AND ELEVATOR FOUNDATION1:20
FIRST FLOOR
FFE 110.51
UNDERPINNING. REFER TO PLAN
AND TYPICAL DETAILS. POUR
UNDERPINNING IN (2) LIFTS
1
1
NEW SHEAR
WALLS, REFER TO
PLAN AND
SCHEDULE
EXISTING SLAB ON
GRADE TO BE REMOVED
ELE
VA
TO
R S
HA
FT
ADD 15M DOWELS INTO UNDERPINNING
AND EXISTING MASONRY WALLS ABOVE.
SPACE AT 800 c/c IN BOTH DIRECTIONS.
DOWEL USING EPOXY GROUT HILTI HY-200.
EMBED INTO CONCRETE/MASONRY MINI 300
WITH EPOXY GROUT HILTI HY-200.
TYP FOR ALL ELEVATOR WALLS IN POURED
DIRECTLY AGAINST EXISTING WALLS AND
UNDERPINNING.
450
300
89
LEAVE FULL DEPTH KEY IN
UNDERPINNING, TYP FOR FULL
PERIMETER OF ELEVATOR PIT SLAB.
ADD DOWELS INTO UNDERPINNING
MATCHING BOTTOM LAYER OF
REINFORCING SIZE AND SPACING. EMBED
INTO UNDERPINNING MIN 600 WITH
EPOXY GROUT HILTIY HY-200. LAP WITH
REBAR MAT IN PIT SLAB MIN 600
20
0
MIN 200 UNDERPINNING
PROJECTION BELOW U/S
ELEVATOR PIT SLAB
300
300
SU
MP
PIT
BY
OT
HE
RS
NEW SLAB ON GRADE NEW SLAB ON GRADE AS
REQUIRED TO ALLOW FOR
UNDERPINNING WORK
NEW SHEAR WALLS, REFER TO
PLAN AND SCHEDULE
NEW SHEAR WALLS,
REFER TO PLAN AND
SCHEDULE
EXISTING 150 CONCRETE
SLAB TO BE REMOVED.
REFER TO PLAN FOR NOTESEXISTING 150 CONCRETE
SLAB TO REMAIN. BEAR
DIRECTLY ON WALLS
BELOW.
AT INTERFACE BETWEEN NEW MASONRY ABOVE,
EXISTING CONCRETE SLAB, AND NEW CONCRETE
WALLS BELOW, DOWELS BETWEEN CONCRETE
WALLS BELOW AND MASONRY WALLS ABOVE TO BE
INSTALLED EITHER BY A) EMBEDING DOWELS IN
CONCRETE PRIOR TO POURING WALLS OR B)
POST-INSTALLING WITH EPOXY GROUT. REFER TO
PLAN AND SCHEDULE FOR DETAILS. TYP ALL AREAS
OF THIS INTERFACE.
EITHER ADJUST MASONRY COURSING ABOVE OR
USE SECONDARY GROUT POUR TO MEET LEVEL 1
ELEVATION AT AREAS WHERE SLAB REMOVED
AFTER WALLS BELOW POURED.
GROUT PACK TOP OF
WALL FOR FULL BEARING
1700
COORDINATE DRAIN LOCATION WITH MECH
AND SUMP PIT PROVIDER. SLOPE TOP OF
PIT SLAB TO SUIT DRAIN LOCATION.
MAINTAIN MINIMUM SLAB THICKNESS
ELEVATOR PIT SLAB TO BE
POURED MONOLITHICALLY
MIN
300
NEW MASONRY SHEAR WALL
BEYOND
NEW CONCRETE SHEAR WALL
BEYOND
EXISTING CONCRETE SLAB TO
REMAIN
EXISTING CONCRETE SLAB TO
BE REMOVED
OVER OPENING IN CONCRETE
WALL:
2-15 T
2-15 EF
2-15 B
10@200 STIRRUPS/U-BARS
EXTEND HORIZONTAL BARS MIN
450 INTO WALL EITHER END OR
PROVIDE HOOKED ENDS INTO
CORES
RE
FE
R T
O A
RC
H
02
S202
CONCRETE HEADER BEAM OVER ELEVATOR OPENING1:20
NEW SHEAR WALLS,
REFER TO PLAN AND
SCHEDULE RE
FE
R T
O A
RC
H
OVER OPENINGS IN MASONRY
SHEAR WALLS, BUILD MASONRY
BOND-BEAM MIN 600 DEEP. R/W
1-25 T, 1-25 B. MIN 20 COVER
AROUND ALL BARS.
MIN 300 BEARING EACH END.
REBAR TO BE CONT THROUGH
LENGTH OF BOND BEAM
AT ENDS OF VERTICAL REBAR
OVER OPENING, FINISH BOTTOM
OF REBAR IN 180-DEGREE HOOK.
ORIENT TO FIT WITHIN BOTTOM
OF BOND BEAM. MAINTAIN MIN
20 COVER AROUND BAR
600
GROUT PACK FOR FULL BEARINGPROVIDE TEMPORARY SHORING TO EXTERIOR
WALLS PRIOR TO EXCAVATION. RELEASE
TEMPORARY SHORING AFTER NEW ELEVATOR
WALLS CAST AND FORMS STRIPPED. COORDINATE
LOCATION OF TEMPORARY SHORING WITH
FORMWORK, OTHER CONTRACTORS. DESIGN OF
TEMPORARY SHORING BY OTHERS.
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
2017-12-22
SECOND FLOOR
FFE 115.43
EXIST LOW ROOF BELOW.
REFER TO ARCH FOR
DEMOLITION.
FACADE AND CLADDING BY
OTHERS. DESIGN FOR THE
FOLLOWING WIND PRESSURE:
POSTIVE : 0.81 kpA
NEGATIVE (SUCTION): -0.71 kPa
CONNECTION TO MASONRY BY OTHERS.
ALL CELLS TO BE GROUTED TO RECEIVE
CONNECTIONS IN ANY LOCATION. DO NOT
INSTALL ANCHORS IN CELLS WITH
VERTICAL REINFORCING UNLESS CELL
HAS BEEN SCANNED FOR REINFORCING
AND LOCATION CONFIRMED. DO NOT
DAMAGE VERTICAL REINFORCING WHEN
INSTALLING ANCHORS. CONTRACTOR TO
SUBMIT SHOP DRAWINGS WITH FACTORED
REACTIONS ON THE MASONRY WALLS FOR
REVIEW PRIOR TO FABRICATION.
20
MARK CELLS WITH
REINFORCING ON OUTSIDE
FACE OF MASONRY FOR WORK
BY OTHERS.
01
S203
CLADDING CONNECTION TO MASONRY SHEAR WALLS1:20
02
S203
FLOOR CONNECTION AT ELEVATOR LOBBY1:20
MAINTAIN MIN GAP FOR
FIRE-SPRAY APPLICATION,
TYP ALL STEEL BEAMS AGAINST
MASONRY
62 CONCRETE ON
38 METAL DECK
DECK CLOSURE ANGLE BY DECK
SUPPLIER
STOP DECK AT EDGE OF
MASONRY WALL. BEND 10M@400
DOWELS INTO FLUTES OF DECK.
MIN 20 COVER AROUND BAR.
POUR CONCRETE OVER
MASONRY WALL BELOW. POUR
STOP/FORM BY OTHERS
400
400
EXISTING CONCRETE SLAB
EXISTING MASONRY WALL
EXISTING MASONRY
WALL BEYOND
EXISTING LINTELVERTICAL
REINFORCING
CONTINUOUS
THROUGH FLOOR
TRANSITION.
03
S203
ELEVATOR LOBBY FLOOR1:20
STUD FRAMING BY OTHERS
MASONRY ELEVATOR SHEAR
WALL BEYOND
STUD FRAMING BY OTHERS TO
CONTINUE PAST FLOOR
STRUCTURE. CONNECTION TO
STRUCTURE BY OTHERS
DECK CLOSURE ANGLE BY
OTHERS
62 CONCRETE ON
38 METAL DECK
SECOND FLOOR
FFE 115.43
DECK CLOSURE
ANGLE BY OTHERS
CUSTOM BENT PLATE 10 THICK FOR
BEARING ON EXISTING MASONRY. MINIMUM
BEARING DIMENSIONS TO BE 200mm DEEP,
300mm WIDE.
ROUT EXISTING MORTAR AT CONNECTION
POINT AND INSERT BENT PLATE. DRIVE
SHIM PLATES OF EQUAL WIDTH AND DEPTH
AS BENT PLATE FOR SNUG BEARING ABOVE
AND BELOW. DO NOT DAMAGE EXISTING
MASONRY AND RE-INSTATE ANY MORTAR
WITH APPROVED MORTAR EQUIVALENT TO
MATCH EXISTING.
200
350
NOTE: VERIFY EXISTING CONDITIONS OF
MASONRY BELOW NEW BEARING PLATE
PRIOR TO CONSTRUCTION. REPAIR ANY
MORTAR JOINTS. CONFIRM MINIMUM
DOUBLE-WYTHE, INTERLOCKED
MASONRY AT ALL LOCATIONS. ALLOW
FOR MODIFICATION TO BEARING PLATE
DESIGN IF SINGLE-WYTHE OR VENEER
PRESENT AT THESE LOCATIONS
04
S203
TYPICAL CONNECTIONS TO NEW AND EXISTING MASONRY1:20
MIN 75, MAX 100 BEARING ON
MASONRY SHEAR WALL
GROUT CELLS TO U/S STEEL
BEAM, ALLOW FOR ERECTION
TOLERANCE, STEEL BEARING
PLATE, AND GROUT BELOW
BEARING PLATE.
INSTALL FACE BLOCK AFTER
STEEL ERECTION
CONTINUOUS REBAR THROUGH
STEEL CONNECTION
2-10Ø x 300 LONG ANCHOR
RODS. GROUT ANCHOR RODS
INTO CELLS BELOW
GROUT CELLS ABOVE AFTER
INSTALLATION OF STEEL BEAM.
VERIFY STEEL BEAM IS GROUT
PACKED AROUND ALL SIDES
STEEL BEAM
04 A
S203
SIMILAR EXCEPT AS NOTED
62 CONCRETE ON 38 METAL DECK.
FOR SECTION 04 A, NO CONCRETE
ON DECK AT THIS LOCATION.
05
S203
CURTAIN WALL CONNECTION AT LEVEL 21:20
CURTAIN WALL CONNECTION
TO STRUCTURE BY OTHERS
CONT L89x89x6.4
HSS76x76x3.2 @ 400 c/c POSTS
FOR CLADDING AND CURTAIN
WALL CONNECTION. CONNECT
TO BENT PLATE BELOW FOR
FULL MOMENT CONNECTION.
EXISTING MASONRY. VARIABLE
DISTANCE AWAY FROM
CLADDING.
CLADDING AND CONNECTION TO
STRUCTURE BY OTHERS
L51x51x3.2 KICKERS AT
EACH HSS POST ABOVE.
CONNECT FOR Tf=Cf=15 kN
BENT PLATE 10 THICK AS
DECK CLOSURE ANGLE
AND SUPPORT FOR HSS
ABOVE
L76x76x4.8 KICKER BACK TO TOP
FLANGE OF PERPENDICULAR W150
BEAM. LOCATE AT MID SPAN OF
PERIMETER BEAM AND CONNECT BACK
TO APPROX 1/3 SPAN OF
PERPENDICULAR BEAM. CONNECT FOR
Tf=Cf=15 kN
62 CONCRETE ON 38 METAL DECK
PORTION OF EXISTING
STRUCTURE/ROOF TO REMAIN.
REFER TO ARCH. RE-SUPPORT
EXISTING STRUCTURE OFF OF
NEW MASONRY SHEAR WALLS.
ALLOW FOR NEW 2-2x10 LEDGER
BOARDS TO SUPPORT EXIST
ROOF. ALLOW FOR ANCHORING
SPACED AT 200 c/c, STAGGERED
300
200
350
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
RADIANT TUBING THROUGH SLAB BY
OTHERS. COORDINATE WITH DECK
SUPPLIER FOR HOLE IN DECK AND
REQUIRED REINFORCING IF NECESSARY.
PIPE TO RUN ADJACENT TO STEEL BEAM
AS SHOWN HERE.
2017-12-22
TOP OF SCREEN
127.85
TOP OF BEAM
127.02
EXISTING ROOF AND EXISTING
MASONRY STRUCTURE
ROOF ANCHOR. REFER TO
PLANS AND TYPICAL DETAILS
ROOF ANCHOR. REFER TO
PLANS AND TYPICAL DETAILS
CLADDING AND CONNECTION TO
STRUCTURE BY OTHERS
MIDDLE ROOF
EL.
THIRD FLOOR / CAFE
FFE EL.120.40
LOW ROOF
EL.
CONT BENT PLATE 10
FOR DECK SUPPORT IN
MASONRY MORTAR BED
100
100
VARIES
38 METAL DECK
ELEVATOR HOIST
BEAM BY ELEVATOR
FABRICATOR
38
METAL
DECK
38 METAL DECK
CONNECTIONS
TO EXISTING
MASONRY AND
NEW MASONRY
AS PER 04/S203
190 MASONRY WALL TO SUPPORT CLADDING/STUD
FRAMING ABOVE. REINFORCE AS PER TYPICAL
DETAILS. ADD DOWELS OR BENT VERTICALS INTO
FLUTES OF DECK BELOW. MAINTAIN MIN 20 COVER
AROUND BAR IN FLUTES
62 CONCRETE ON 38
METAL DECK
DECK CLOSURE
ANGLE BY DECK
SUPPLIER
DECK CLOSURE
ANGLE BY DECK
SUPPLIER
CLADDING AND STUD FRAMING
BY OTHERS. CONNECTION TO
STRUCTURE BY OTHERS
CLADDING AND STUD FRAMING
BY OTHERS. CONNECTION TO
STRUCTURE BY OTHERS
01
S204
HIGH ROOF AND MID ROOF FRAMING
1:20
02
S204
MID ROOF, LOW ROOF, AND THIRD FLOOR FRAMING
1:20
CONNECTIONS
TO MASONRY AS
PER 04/S203
MAINTAIN MIN GAP FOR
FIRE-SPRAY APPLICATION,
TYP ALL STEEL BEAMS AGAINST
MASONRY
CANT ROOF DECK PAST STEEL
BEAMS, TYP BOTH ENDS
ROOF ANCHOR. REFER TO
PLANS AND TYPICAL DETAILS
±580 SITE VERIFY
RE
FE
R T
O A
RC
H
GROUT PACK TOP OF LINTEL
2-W150x22 LINTELS W/ CONT ±580x13 TOP PLATE,
±580x200x13 BASEPLATE EACH END, ADD 100 WIDE
x 6.4 THICK BOTTOM PLATE AT MIDSPAN
BASEPLATE BEYOND, BEAR ON
MIN 200 MASONRY. GROUT
UNDER BASEPLATE FOR EVEN
BEARING
03
S204
NEW LINTEL THROUGH EXISTING MASONRY IN CAFE
1:20
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
RADIANT TUBING THROUGH SLAB BY
OTHERS. COORDINATE WITH DECK
SUPPLIER FOR HOLE IN DECK AND
REQUIRED REINFORCING IF NECESSARY.
PIPE TO RUN ADJACENT TO STEEL BEAM
AS SHOWN HERE.
2017-12-22
SECOND FLOOR
FFE EL. 115.43
NEW STEEL COLUMN ABOVE. DO NOT
INSTALL COLUMN ABOVE UNTIL
BRACES/BRIDGING INSTALLED
BELOW
PATCH HOLES IN EXISTING FLOOR WITH
GROUT. PREPARE EDGES OF EXISTING
CONCRETE SO THAT NEW GROUT WILL
BEAR ON SLOPED AND ROUGHENED
EDGES. REPAIR EXISTING STEEL PAN
BELOW AS REQUIRED.
EXISTING CEILING, REFER TO
ARCH
EXISTING OWSJREFER TO PLAN FOR
LOCATING EXISTING
OWSJ AND
POTENTIAL
RELOCATION OF
EXISTING OWSJ
L38x38x4.8, TYP FOR
ALL NEW BRIDGING
SUPPORTING TOP
FLANGES OF NEW
BEAMS. INSTALL AT
EACH QUARTER
POINT AND AT EACH
COLUMN ABOVE.
CONNECT FOR
Tf=Cf=20 kN
EXISTING BRIDGING
REMOVED AND
REINSTATED
NEW STEEL BEAM
SUPPORTING
COLUMN ABOVE
01
S205
NEW STEEL BEAMS SUPPORTING COLUMNS ABOVE1:20
REMOVE EXISTING MASONRY TO INSTALL NEW BEAMS
AND BEARING PLATES. DO NOT UNDERMINE EXISTING
BEARING SUPPORTS FOR ADJACENT OWSJ. PROVIDE
TEMPORARY SHORING TO ADJACENT OWSJ IF ANY
EXISTING MASONRY WILL BE REMOVED WITHIN A 1:1
SLOPE FROM THE OWSJ BEARING LINE
STIFFENER PLATES
BEARING PLATE ON 50 GROUT
UNDER NEW STEEL BEAMS.
REFER TO PLAN FOR MINIMUM
PLATE SIZES AND ANCHORING
ADD SOLID PRECAST CONCRETE
BLOCK WHERE NEW STEEL
BEARING PLATE IS >50mm FROM
U/S OF STEEL BEAM. IF BEARING
SURFACE <50mm, GROUTED
BUILD-UP MAY BE USED.
EXISTING CONCRETE ON METAL
PAN FLOOR
EXISTING CONCRETE ON METAL
PAN FLOOR
EXISTING MASONRY
WALLS
02
S205
NEW STEEL BEAMS ON EXISTING MASONRY1:20
NEW STEEL BEAM NEW STEEL BEAM
03
S205
NEW STEEL BEAMS ON EXISTING MASONRY1:20
03
S205
02
S205
IF INSTALLATION OF GROUT,
STEEL PLATE, STEEL BEAM ETC
WOULD INTERFERE WITHIN 1:1
SLOPE FROM EXISTING OWSJ
BEARING, TEMPORARILY
SUPPORT EXISTING OWSJ AND
FILL ENTIRE REGION WITHIN
BEARING ZONE WITH GROUT.
04
S205
04
S205
NEW STEEL BEAMS ON EXISTING MASONRY1:20
02
S205
EXTEND STIFFENER PLATES TO
EDGE OF BEARING PLATE, TYP
FOR ALL BEARING PLATES AND
BEAMS
LIBRARY MEZZANINE
FFE EL. 119.77
CONT STEEL BY OTHERS, REFER
TO ARCH
MILLWORK
STUD BACKUP FOR MILLWORK
BY OTHERS. CONNECTION TO
STRUCTURE BY OTHERS.
PROVIDE LATERAL BRACING
BACK TO STRUCTURAL STEEL.
DO NOT CONNECT TO STEEL
DECK. PROVIDE CONTINUOUS
MEMBERS AT UNDERSIDE OF
STEEL BEAMS AS REQUIRED.
COLUMN BEYOND
05
S205
GUARD DETAIL AT MEZZANINE LEVEL1:20
CEILING BEYOND
62 CONCRETE ON 38
METAL DECK
62 CONCRETE ON 38
METAL DECK
CONT DECK CLOSURE
ANGLE L102x102x6.4
CONT DECK CLOSURE ANGLE
L102x102x6.4
06
S205
GUARD DETAIL AT MEZZANINE LEVEL1:20
GUARDRAIL, GUARDRAIL
CONNECTIONS TO STRUCTURE
BY OTHERS.
EXISTING
MASONRY
EXTERIOR WALL
07
S205
MEZZANINE CONNECTION DETAIL TO EXISTING MASONRY1:20
62 CONCRETE ON 38
METAL DECK
CONT DECK CLOSURE
ANGLE L102x102x6.4
EXISTING
MASONRY
EXTERIOR WALL
CUSTOM BENT PLATE 10 THICK FOR
BEARING ON EXISTING MASONRY.
MINIMUM BEARING DIMENSIONS TO BE
200mm DEEP, 300mm WIDE.
ROUT EXISTING MORTAR AT
CONNECTION POINT AND INSERT BENT
PLATE. DRIVE SHIM PLATES OF EQUAL
WIDTH AND DEPTH AS BENT PLATE FOR
SNUG BEARING ABOVE AND BELOW. DO
NOT DAMAGE EXISTING MASONRY AND
RE-INSTATE ANY MORTAR WITH
APPROVED MORTAR EQUIVALENT TO
MATCH EXISTING.200
35
0
PLASTER/WALL FINISH
REFER TO ARCH FOR REQUIRED
CONNECTION DETAILS AT
EXPOSED CONDITIONS. EXPOSED
STEEL TO RECEIVE INTUMESCENT
PAINT, REFER TO ARCH.
KNIFE PLATE/CHANNEL/SHOE TO
BE SHOP WELDED TO PLATE.
BOLTED CONNECTION FROM
BEAM TO PLATE TO BE
CONCEALED WITHIN FINISHES.
DESIGN WELDED CONNECTION TO
PLATE ALLOWING FOR
ECCENTRICITY
BENT STEEL PLATE TOE GUARD
AND EMBEDDED ITEMS BY
OTHERS. CONNECTION TO
STRUCTURE BY OTHERS
W150 BEAMS
W150 BEAMS
300
200
350
LIBRARY MEZZANINE
FFE EL. 119.77
MEZZANINE OVERLOOK
FFE EL. 120.25
STEEL STUD
FRAMING FOR
GROUP STUDY
ROOMS BY OTHERS
62 CONCRETE ON
38 METAL DECK
W150 BEAM
SUPPORTING RAMP
62 CONCRETE
ON 38 METAL
DECK
CANT STEEL BEAM
STEEL COLUMN
RAMP MID LANDING
FFE EL. 119.99
RAMP
62 CONCRETE ON
38 METAL DECK
CONT DECK CLOSURE
ANGLE L102x102x6.4
GUARDRAIL, GUARDRAIL
CONNECTIONS TO
STRUCTURE BY OTHERS.
SLOPED, CRANKED RAMP BEAM
HSS POST
62 CONCRETE ON 38
METAL DECK
STUD FRAMING AND HANDRAIL
BY OTHERS. CONNECTION TO
STRUCTURE BY OTHERS
CONT DECK CLOSURE ANGLE
L152x102x6.4 (LLH)
CONT DECK CLOSURE
ANGLE L102x102x6.4
SHIM U/S BEAM FOR EVEN
BEARING. BOLT THROUGH
SHIMS AS NECESSARY
08
S205
MEZZANINE DETAIL AT GROUP STUDY ROOM1:20
09
S205
DETAIL THROUGH RAMP AND GUARDRAIL CONNECTION1:20
10
S205
DETAIL AT LOW BEAM CONNECTION UNDER MEZZANINE1:20
STUD FRAMING AND HANDRAIL
BY OTHERS. CONNECTION TO
STRUCTURE BY OTHERS
RAMP
62 CONCRETE ON
38 METAL DECK
LANDING LEVEL
FFE EL. 119.13FMC
FMC
GUARDRAIL, GUARDRAIL
CONNECTIONS TO STRUCTURE
BY OTHERS.
62 CONCRETE ON
38 METAL DECK
HSS102x102x3.2 HANGER
BENT PL 200x100x6.4 (LLH)
DECK CLOSURE ANGLE.
62 CONCRETE
ON 38 METAL
DECK
CONT L76x51x4.8
FOR DECK
SUPPORT, TYP
EACH SIDE
10
0
30
MIN 30 CONCRETE
OVER STEEL FLANGES
EMBEDDED IN
CONCRETE
BENT PL 30x100x4.8 (LLH) DECK
CLOSURE ANGLE, TYP ALL
SIDES
INTUMESCENT PAINT AT
EXPOSED STEEL AND WHERE
FIRESPRAY APPLICATION NOT
POSSIBLE DUE TO SPACE
RESTRICTIONS
11
S205
STAIR LANDING CONNECTIONS TO STRUCTURE1:20
LANDING LEVEL
FFE EL. 119.13
12
S205
12
S205
DETAIL THROUGH LANDING1:20
STAIRS, TREADS, RAILINGS, ETC. BY
OTHERS. CONNECTION TO
STRUCTURE BY OTHERS
CONT L76x51x4.8 FOR DECK
SUPPORT, TYP ALL EDGES
62 CONCRETE ON
38 METAL DECK
COORDINATE TOP
TREAD, FLOOR FINISH,
AND TOP OF CONCRETE
VOIDBENT PL 30x100x4.8 (LLH) DECK
CLOSURE ANGLE, TYP ALL SIDES
HANGER BEYOND
STAIRS, TREADS, RAILINGS, ETC. BY
OTHERS. CONNECTION TO
STRUCTURE BY OTHERS150
SHOP WELD BEAM EXTENSION TO FACE OF WALL
PLATE. FIELD SPLICE TO REMAINDER OF BEAM.
FIELD SPLICE TO DEVELOP FULL MOMENT AND
SHEAR CAPACITY OF BEAM. FULLY CONCEAL
SPLICE CONNECTION. INTUMESCENT PAINT AT
EXPOSED STEEL, REFER TO ARCH
05-A
S205
DEATIL AT WORK ROOM BELOW1:20
SIMILAR EXCEPT AS NOTED
SECTION 05-A/S205 ONLY
CANT STUD FRAMING AT LOW
LEVEL. DESIGN AND
CONNECTION TO
STRUCTURE BY OTHERS.
DESIGN FOR 4.8 kPa LIVE
LOAD. DO NOT CONNECT TO
EXISTING STONE SILL.
PROVIDE BRACES/KICKERS
AS NECESSARY BACK TO
STEEL STRUCTURE TO
SUPPORT CANT EDGE
07-A
S205
DETAIL AT WORK ROOM BELOW1:20
SIMILAR EXCEPT AS NOTED
SECTION 07-A/S205 ONLY
ADD L102x102x4.8 OR
BENTPLATE AS REQUIRED TO
CLOSE GAP TO EXISTING WALL.
REFER TO ARCH
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
2017-12-22
MEZZANINE OVERLOOK
FFE EL. 120.25
200 FROM EDGE OF MASONRY WALL
CAFE
FFE EL. 120.40
EXISTING MASONRY WALL
BEYOND
EXISTING WOOD FRAMING
BELOW
NEW DUCTS, REFER TO ARCH
AND MECH
EXISTING STAIRS, SLAB TO BE
REMOVED
ADD 15M @ 300 x 600 LONG DOWELS INTO
EXIST CONCRETE. EMBED MIN 300 USING
EPOXY GROUT HILTI HY-200 AT MID HEIGHT
OF EXISTING CONCRETE SLAB
CLOSURE ANGLE AS REQUIRED
OR CAST DIRECTLY AGAINST
EXISTING CONCRETE
CONCRETE EDGE BEYOND
62 CONCRETE ON
38 METAL DECK
BACK TO BACK CONT CLOSURE
ANGLES OR BENT PLATES BY
DECK SUPPLIER.
BACK TO BACK CONT CLOSURE
ANGLES OR BENT PLATES BY
DECK SUPPLIER.
CONT L102x102x6.4 DECK
CLOSURE ANGLE
GUARDRAIL AND STUD FRAMING
BY OTHERS. CONNECTION TO
STRUCTURE BY OTHERS
SHIM FOR
EVEN BEARING
150 CONCRETE ON
38 FORM DECK
INTUMESCENT PAINT ON STEEL
BEAMS IN THIS AREA
EXISTING MASONRY WALL
CONNECT TO EXISTING
MASONRY WALL SIMILAR TO
07/S205. TYP FOR ALL
CONNECTIONS IN
LANDING/RAMP AREA
W150x18 TO SUPPORT DECK
EDGE BEYOND.
RAMP
150 CONCRETE ON
38 FORM DECK
01
S206
FLOOR CONNECTION TO EXISTING CAFE LEVEL1:20
02
S206
DETAIL THROUGH RAMP AT CONNECTION TO CAFE LEVEL1:20
GUARDRAIL BY OTHERS.
CONNECTION TO STRUCTURE
BY OTHERS
TAPERED BENT PLATE ALONG
SLOPED BEAM FOR DECK
CLOSURE ANGLE.
02
S206
150 CONCRETE ON
38 FORM DECK
DECK CLOSURE ANGLE BY
DECK SUPPLIER
WELD DECK CLOSURE ANGLE
TO UPPER CLOSURE ANGLE
62 CONCRETE
ON 38 METAL
DECK
03
S206
DETAIL THROUGH TRANSITION AT CAFE LEVEL TO MEZZANINE1:20
OFFICE
FFE EL. 120.40
04
S206
NEW GUARDRAIL INTEGRATED WITH NEW TOPPING OVER EXSITING FLOOR1:20
75
1
1
06
S206
NEW TOPPING AND FRAMING OVER DUCTS IN OFFICE1:20
300
600
05
S206
ANCHOR FOR GUARDRAIL AT EDGE OF TOPPING1:10
3-10M WELDABLE REBARS
SPACED @ 300 c/c AROUND ALL
EDGES OF GUARDRAIL
CONTINUOUS CAST-IN-PLATE 10
THICK TO ACT AS CLOSURE
FORM FOR CONCRETE AND
GUARDRAIL ATTACHMENT
EXISTING EXTERIOR
MASONRY WALL
EXISTING OWSJ
EXISTING CONCRETE
ON METAL PAN
BUILD-UP WITH RIGID
INSULATION
GUARDRAIL BY OTHERS.
CONNECTION TO STRUCTURE
BY OTHERS
WELD REBAR TO PLATE
WELD REBAR TOGETHER, TYP AT
ALL INTERSECTIONS OF REBAR.
NOTE: USE WELDABLE GRADE
REBAR ONLY
05
S206
EXISTING OWSJ AND CONCRETE
ON METAL PAN TO BE REMOVED
REFER TO ARCH
BUILD-UP WITH RIGID INSULATION
EXISTING MASONRY WALL
BEYOND
EXIST OFFICE ELEVATION
FFE EL. VARIES
HISTORIC CEILING BELOW. REFER TO ARCH.
SUSPENDED DUCTS AND SERVICES BELOW NEW SLAB.
REFER TO MECH AND ARCH
300
EXISTING OWSJ AND CONCRETE
TO REMAIN SOUTH OF SAWCUT
LINE. REPLACE BRIDGING AS
NECESSARY
SAWCUT MAX 50 FROM
EDGE OF OWSJ BELOW
STEEL BEAMS IN THIS
AREA TO RECEIVE
INTUMESCENT PAINT
150 CONCRETE ON 38 METAL
DECK
CONT L76x76x6.4 DECK
CLOSURE ANGLE
EXTEND MESH MIN 300 INTO
CONCRETE ON DECK
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
07
S206
TRENCH FOR DOOR OPERATOR1:20
SECOND FLOOR
FFE EL. 115.43
127 DEEP TRENCH W 178 DEEP PIT @ EACH
END. FOR DOOR OPERATOR REFER TO DOOR
SCH. DO NOT UNDERMINE JOIST SHOES
12
7
76
EXISTING CONCRETE ON METAL
PAN FLOOR
FLOOR CONDITION VARIES BOTH SIDES
EXISTING OWSJ
2017-12-22
04
S207
GLAZING PARTITION CONNECTION1:20
EXISTING CONCRETE SLAB
CONT L152x102x7.9 (LLH). FASTEN TO EXISTING
CONCRETE SLAB WITH HILTI KWIK-BOLT 3, MIN 50
EMBEDMENT, SPACED AT 600 c/c
L51x51x4.8 KICKER
SPACED AT 600 c/c
NEW W310 BEAM.
25 GROUT PACK TOP OF
BEAM TO EXISTING SLAB
CONT L 102x102x4.8 FOR TOP OF
GLAZING PARTITION SUPPORTL51x51x4.8 HANGER SPACED AT 600 c/c
DROP CEILING. REFER TO
ARCH FOR ELEVATION
GLAZING PARTITION.
CONNECTION TO STEEL BY
OTHERS.
EXISTING 18" OWSJ
EXISTING CONCRETE ON DECK
PROJECTION BOOTH
TOP OF SLAB EL. 111.29
FIRST FLOOR, WEST WING
TOP OF SLAB EL. 110.51
FIRST FLOOR, CROFT CHAPTER HOUSE
TOP OF SLAB EL. VARIES
SECOND FLOOR
FFE EL. 115.43
EXISTING LOAD BEARING
MASONRY WALL
EXISTING 8" MASONRY WALL
EXISTING 8" MASONRY WALL EXISTING 10" MASONRY WALL
EXISTING LOAD BEARING
MASONRY WALL
NEW SLAB INFILL TYPE S1.
REFER TO PLAN
NEW TOP OF CONCRETE, LECTURE HALL
TOP OF SLAB EL. 109.36
NEW CHANNELS ACROSS
EXISTING MASONRY OPENINGS
FOR NEW MECHANICAL DUCTS.
INSTALL AND GROUT TOP OF
NEW CHANNELS PRIOR TO
OPENING MASONRY WALL.
EXISTING 8" MASONRY WALL
CLEAN EXISTING CONCRETE AND APPLY
BONDING AGENT BETWEEN EXISTING
CONCRETE AND NEW GROUT. ALLOW FOR
GROUT TO ACHIEVE FULL STRENGTH
PRIOR TO CUTTING HOLES IN MASONRY NEW C200x17 CHANNELS
ACROSS OPENING, BOTH SIDES.
EXTEND PAST EDGE OF
EXISTING/NEW OPENING MIN
700. AT EACH END OF OPENING,
INSTALL 6-13Ø THROUGH BOLTS.
STAGGER BOLTS TOP AND
BOTTOM, 100 c/c
38
100 100100
EXISTING MASONRY WALL
EDGE OF EXISTING MASONRY
OR EDGE OF NEW OPENING
THROUGH MASONRY. DO NOT
CUT MASONRY UNTIL CHANNELS
INSTALLED AND GROUTED
RIGID INSULATION UNDER NEW CONCRETE
TOPPING. REFER TO PLAN
01
S207
SECTION THROUGH TIERED SEATING AND PROJECTION BOOTH1:20
02
S207
NEW CHANNELS ACROSS OPENING DETAIL1:20
02
S207
NEW CHANNELS ACROSS
EXISTING AND NEW OPENING.
REFER TO NOTES BELOW
EXISTING PROJECTION BOOTH CONCRETE
SLAB. REMOVE SLAB AND UPSTAND
CONCRETE WALL. MAKE GOOD
CONCRETE AT CONNECTIONS.
NEW CONCRETE TIERED STEP
TO MATCH EXISTING.
ROUGHEN EXISTING CONCRETE
SURFACE AND APPLY BONDING
AGENT
DOWEL NEW REBAR INTO EXISTING
SLAB. EMBED 100 MIN. USE HILTI
HY-200 EPOXY GROUT
300
NEW 10M @ 400 REBAR.
DOWEL INTO EXISTING
CONCRETE, SPLICE MIN 300.
4-10M CONT REBAR. DOWEL
INTO EXISTING CONCRETE
TIERED SLAB, BOTH SIDES.
EMBED MIN 100. STAGGER
SPLICES AS REQUIRED. MIN
300 SPLICE FOR ALL BARS
PARTITION/GUARDRAIL DESIGN BY
OTHERS. CONNECTION TO STRUCTURE BY
OTHERS. CAST-IN-PLATE BY OTHERS.
CONNECTION TO STRUCTURE BY OTHERS.
MAX 2" SLOT INTO EXISTING SLAB AT BASE
OF RAMP.
NEW SLAB
INFILL TYPE
S1. REFER
TO PLAN
RIGID INSULATION UNDER
NEW CONCRETE TOPPING.
REFER TO PLAN
EXISTING LOAD BEARING
MASONRY WALL
EXISTING 7" CONCRETE SLAB
EXISTING CONCRETE TIERED
SLAB, MIN THICKNESS 7"
EXISTING CONCRETE TIERED
SLAB, MIN THICKNESS 7"
150 WIDE CONCRETE UPSTAND.
REINFORCE WITH 10M @ 400 V
DOWELED INTO EXISTING
CONCRETE BELOW. ADD CONT
2-10M H. ROUGHEN CONCRETE
SURFACE BELOW AND APPLY
BONDING AGENT
DOWEL NEW REBAR INTO EXISTING
SLAB. EMBED 100 MIN. USE HILTI
HY-200 EPOXY GROUT
300
VA
RIE
S. R
EF
ER
TO
AR
CH
FIRST FLOOR, CROFT CHAPTER HOUSE
TOP OF SLAB EL. VARIES
03
S207
SECTION THROUGH RAMP1:20
NEW CHANNEL AND 12Ø
THROUGH-BOLTS.
GROUT PACK
BETWEEN CHANNEL
AND EXISTING TIERED
SLAB
150
EXISTING STAIR LANDING
7" CONCRETE SLAB
EXISTING 8" MASONRY WALL
DROP CEILING. REFER TO ARCH
FOR ELEVATION
REMOVE EXISTING MASONRY
CHIMNEY BELOW SECOND
FLOOR.
EXISTING MASONRY
CHIMNEY/ LOAD
BEARING MASONRY
WALL
EXISTING MASONRY
CHIMNEY ABOVE
NEW LINTEL TO SUPPORT EXISTING MASONRY CHIMNEY ABOVE.
2-W250x101 W/ CONT PL10, 600 WIDE TOP.
GROUT PACK TOP OF PLATE TO UNDERSIDE OF EXISTING
MASONRY CHIMNEY
05
S207
NEW LINTELS AT EXISTING CHIMNEY REMOVAL1:20
EXISTING MASONRY WALL
REMOVED
06-B
S207
SECTION THROUGH FULL DEPTH TRENCH IN EXISTING SLAB1:20
EQ
EQ
WIDTH DETERMINED BY CONTRACTOR
06-A
S207
SECTION THROUGH PARTIAL DEPTH TRENCH IN EXISTING SLAB1:20
IF DEPTH OF TRENCHING FOR NEW SERVICES DOES NOT
EXCEED 1/2 OF THE EXISTING SLAB DEPTH AND NO
REBAR IS TO BE CUT/DAMAGED, PARTIAL TRENCH MAY BE
ACCEPTABLE. ROUGHEN SIDES OF EXISTING CONCRETE
AND APPLY BOND BREAKER PRIOR TO POURING NEW
CONCRETE
IF DEPTH OF TRENCH WOULD EXCEED 1/2 OF
THE THICKNESS OF THE EXISTING CONCRETE
SLAB OR EXISTING REBAR IS TO BE
CUT/DAMAGED, REMOVE FULL DEPTH OF SLAB.
EXTENT OF REMOVAL TO BE FROM EDGES OF
SUPPORTING MEMBERS ON EACH SIDE
EXISTING CONCRETE SLAB
EXISTING REINFORCING IN SLAB
TO REMAIN.
EXISTING CONCRETE SLAB
EXISTING REINFORCING
IN SLAB TO REMAIN.
CUT EXISTING REINFORCING RUNNING
PERPENDICULAR TO DIRECTION OF THE
TRENCH.
ADD 10@400 x 350 LONG DOWELS, STAGGERED EACH SIDE
INTO EXISTING CONCRETE. USE HILTI HY-200 EPOXY
GROUT, MIN 100 EMBEDMENT.
ADD 2-15 CONT
NOTE: CONTRACTOR TO SCAN FOR REBAR AND SERVICES IN SLABS AND
SLABS ON GRADE PRIOR TO CUTTING. ADJUST LAYOUT AS NECESSARY. IN ALL
CASES, DO NOT CUT REBAR RUNNING PARALLEL WITH THE DIRECTION OF THE
TRENCH. REBAR RUNNING PERPEDICULAR TO THE DIRECTION OF THE TRENCH
MAY BE CUT ONLY WITH REVIEW BY THE STRUCTURAL ENGINEER.
CONDUITS FOR REFERENCE
ONLY. DO NOT TIE CONDUITS
TO LONGITUDINAL REBAR
75 CONT BENT PL5 FOR CONCRETE SUPPORT DURING
POURING. DIMENSIONS OF PLATE TO BE DETERMINED
BASED ON TRENCHING AND SITE CONDITIONS. FASTEN
TO EXISTING CONCRETE LEDGE WITH 10Ø EXPANSION
ANCHOR SPACED AT @800, STAGGERED EACH SIDE.
ADD 2-10 CONT
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
FIRST FLOOR, CROFT
CHAPTER HOUSE
TOP OF SLAB EL. VARIES
NEW TOP OF CONCRETE,
LECTURE HALL
TOP OF SLAB EL. 109.36
EXISTING LOAD BEARING
MASONRY WALL
EXISTING 8" MASONRY WALL
NEW SLAB INFILL TYPE S1.
REFER TO PLAN
EXISTING 8" MASONRY WALL
150 CONCRETE CURB. REINFORCE WITH 10M
@ 300 VERTICAL. DOWEL INTO SLAB BELOW
WITH HILTI HY-200 EPOXY GROUT. MIN
EMBEDMENT TO BE 100. DOWEL WITH SLAB
ABOVE WITH MATCHING REBAR.
BENT PLATE AND
CONNECTIONS SIMILAR
TO 7/S205 EXCEPT AS
NOTED. DIMENSIONS
AS FOLLOWS
125
100175
07
S207
SECTION THROUGH INFILL FLOOR IN CLASSROOM1:20
PL100x10 CONTINUOUS PLATE WITH
16 mm Ø ANCHOR BOLT @ 600 mm
15M@400 BLL
10M@400 BUL
2017-12-22
SECOND FLOOR
FFE EL. 115.43
01
S208
NEW LINTEL SUPPORTING MASONRY AND EXISTING SLAB1:20
EXISTING MASONRY EXTERIOR
WALL
300
CUT AND REMOVE EXISTING
MASONRY TO FORM POCKET
FOR BEAM INSTALLATION.
GROUT UNDERSIDE OF NEW
BASEPLATE. MAX DEPTH OF
NEW GROUT TO BE 50
STEEL BASEPLATE. 300 x 500 x 20
THICK
STIFFENER PLATES
EACH SIDE
EXISTING CONCRETE SLAB
GROUT PACK TOP OF STEEL
BEAM
EXISTING MASONRY WALL ABOVE
EXISTING MASONRY
WALL BELOW REMOVED
02
S208
NEW SLAB CONNECTION TO EXISTING MASONRY1:20
SAWTOOTH NEW CONCRETE
INTO EXISTING MASONRY WALL.
ADD 1-10M HOOKED REBAR x 600
LONG AT EACH SAWTOOTH
EXISTING WALL ABOVE
EXISTING WALL BELOW REMOVED
EXISTING WALL BEYOND
NEW W250
BENT PL178x152x6.4 FOR
CLOSURE ANGLE
03
S208
NEW SLAB CONNECTION TO EXISTING CONCRETE1:20
EXISTING CONCRETE SLAB
ADD 10M @ 300 x 600 LONG
DOWELS INTO EXISTING
CONCRETE. DOWEL WITH
EPOXY GROUT HILTI HY-200, MIN
EMBEDMENT 300
EXISTING STAIR LANDING
7" CONCRETE SLAB
EXISTING 8" MASONRY WALL
DROP CEILING. REFER TO ARCH
FOR ELEVATION
EXISTING
MASONRY
CHIMNEY
BEYOND
04
S208
NEW LINTELS AT EXISTING CHIMNEY REMOVAL1:20
NEW CONCRETE SLAB
REMOVE PROJECTIONS/CANTILEVERED PORTIONS
OF CONCRETE SLAB. PROVIDE ROUGHENED
SURFACE AT INTERFACE BETWEEN NEW AND
EXISTING CONCRETE
LINTELS SUPPORTING
CHIMNEY BEYOND
STIFF PLATES
BREAK OUT AND REMOVE
PORTIONS OF EXISTING
MASONRY AND CONCRETE TO
FIT NEW LINTEL.
PROVIDE MIN 400 WIDE BASE
PLATE AT CONNECTION TO
EXISTING MASONRY. GROUT
SOLID ALL CELLS DIRECTLY
BELOW NEW BASEPLATE
SECTION 04A:
TRANSFER ONTO NEW W250
LINTEL. SIMILAR BEARING
PLATES AT EACH SIDE OF NEW LINTEL
NEW MASONRY INFILL WALL.
REFER TO PLAN
SIMILAR EXCEPT AS NOTED
FIRST FLOOR
FFE EL. ELEVATION VARIES
EXISTING MASONRY WALL ABOVE
AND BELOW
EXISTING OPENING THROUGH
MASONRY WALL
EXISTING CONCRETE SLAB
NEW W200x46 SUPPORTING NEW
MASONRY WALL ABOVE.
POCKET INTO EXISTING
MASONRY
NEW 200 x 300 x 20 BASEPLATE.
MIN 25 GROUT UNDER
BASEPLATE
GROUT BETWEEN EXISTING
MASONRY AND TOP OF STEEL
BEAM
NEW MASONRY INFILL
SUPPORTING TRANSFER
BEAMS ABOVE
05
S208
NEW STEEL BEAM SUPPORTING NEW MASONRY INFILL1:20
SECOND FLOORFFE EL. 115.43
EXISTING STAIR LANDING
7" CONCRETE SLAB
EXISTING 8" MASONRY WALL
06
S208
NEW LINTELS AT EXISTING STAIR1:20
NEW W250 LINTEL TO SUPPORT
EDGE BEAM, STAIR BEAM, NEW
LINTEL, GROUT TO U/S OF EXIST.
DOWNTURN BEAM
EXISTING STAIR BEAM,
STAIR RISERS, AND
TREAD TO REMAIN
NEW STEEL WALL PLATE 10 THICK.
WITH 8-19Ø HILTI HIT-Z RODS WITH
EPOXY GROUT HILTI HY-200,
EMBEDMENT MIN 100
450
300
100
MIN
15
0
07
S208
NEW WALL PLATE1:20
07
S208
08
S208
NEW LINTEL UNDER EXISTING MASONRY WALL1:20
09
S208
NEW LINTEL INTO EXISTING MASONRY1:20
SECOND FLOOR
FFE EL. 115.43
NOTE:
REFER TO P-SERIES DRAWINGS
FOR REQUIREMENTS FOR
PROTECTION OF THE EXISTING
BUILDING
CONNECT FOR
Vf = 130 kN
LC
228
LC
EXISTING WALL BEYOND
EXISTING WALL BEYOND.
CUT AND REMOVE
EXISTING MASONRY TO
FORM POCKET FOR BEAM
INSTALLATION. GROUT
UNDERSIDE OF NEW
BASEPLATE. MAX DEPTH
OF NEW GROUT TO BE 50
EXISTING WALL BEYOND
NEW OPENING
PL200x16x170 BEARING PLATE
550x400x300 DEEP
CONCRETE BEARING
PAD
30
0
550
STIFFENER PLATES AT
BEAREING LOCATION
2017-12-22