S6S1-10 © Canadian Standards Association May 2010 10.10.2.2 Laterally supported members When continuous lateral support is provided to the compression flange of a member subjected to bending about its major axis, the factored moment resistance, M r , shall be calculated as M r = s Z x F y = s M px 10.10.2.3 Laterally unbraced members For a section subjected to bending about its major axis and laterally unbraced over a length, L, the factored moment resistance, M r , shall be calculated as (a) ; or (b) M r = s M u , when M u 0.67M p The critical elastic moment, M u , of a monosymmetric section shall be taken as where where M max = maximum factored bending moment magnitude in unbraced segment, N•mm M a = factored bending moment at one-quarter point of unbraced segment, N•mm M b = factored bending moment at midpoint of unbraced segment, N•mm M c = factored bending moment at three-quarter point of unbraced segment, N•mm L = length of unbraced segment of beam, mm B 1 = where x = coefficient of monosymmetry B 2 = For doubly symmetric sections, x = 0.0 B 1 = 0.0 so that M u = The general expression for the critical elastic moment and formulas for x , J, and C w for I-girder and open-top box girders as specified in Clause C10.10.2.3 of CSA S6.1 may be used for guidance. A more rigorous analysis, taking into account both elastic and inelastic behaviour, may also be used. 10.10.2.4 Bending about the minor axis For a section subjected to bending about its minor axis, whether laterally braced or unbraced, the factored moment resistance, M r , shall be calculated as M r = s Z y F y = s M py M M M M M M M r s p p u s p u p = > 1 15 1 0 28 0 67 . . , . f f when M L EIGJB B B u sy s = + + + w 2 1 2 1 2 1 π w 2 2 2 2 2 4 4 7 4 25 = + + + M M M M M b c max max a . π b x sy s L EI GJ 2 π 2 2 EC LGJ s w s w 2 2 π L EIGJ E L lC sy s s y w + p (Replaces p. 456, November 2006) 456 Single user license only. Storage, distribution or use on network prohibited

Upload: vuongtram

Post on 10-Mar-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.10.2.2 Laterally supported membersWhen continuous lateral support is provided to the compression flange of a member subjected to bending about its major axis, the factored moment resistance, Mr , shall be calculated as

Mr = s Zx Fy = sMpx

10.10.2.3 Laterally unbraced membersFor a section subjected to bending about its major axis and laterally unbraced over a length, L, the factored moment resistance, Mr , shall be calculated as

(a) ; or

(b) Mr = s Mu , when Mu 0.67MpThe critical elastic moment, Mu , of a monosymmetric section shall be taken as

where

where

Mmax = maximum factored bending moment magnitude in unbraced segment, N•mm

Ma = factored bending moment at one-quarter point of unbraced segment, N•mm

Mb = factored bending moment at midpoint of unbraced segment, N•mm

Mc = factored bending moment at three-quarter point of unbraced segment, N•mm

L = length of unbraced segment of beam, mm

B1 =

where

x = coefficient of monosymmetry

B2 =

For doubly symmetric sections,

x = 0.0

B1 = 0.0

so that

Mu =

The general expression for the critical elastic moment and formulas for x , J, and Cw for I-girder and open-top box girders as specified in Clause C10.10.2.3 of CSA S6.1 may be used for guidance. A more rigorous analysis, taking into account both elastic and inelastic behaviour, may also be used.

10.10.2.4 Bending about the minor axisFor a section subjected to bending about its minor axis, whether laterally braced or unbraced, the factored moment resistance, Mr , shall be calculated as

Mr = s Zy Fy = s Mpy

M MM

MM M Mr s p

p

us p u p= −

⎣⎢

⎦⎥ ≤ >1 15 1

0 280 67.

., .f f when

ML

E I G J B B Bu s y s= + + +⎡⎣⎢

⎤⎦⎥

⎡⎣⎢

⎤⎦⎥

w21 2 1

21π

w2 2 2 2 2

4

4 7 42 5 =

+ + +≤

M

M M M Mb c

max

max a

.

πbx s y

sL

E I

G J2

π2

2

E C

L G Js w

s

w22π

LE I G J

EL

l Cs y ss

y w+ ⎡⎣⎢

⎤⎦⎥

p

(Replaces p. 456, November 2006)456

Single user license only. S

torage, distribution or use on network prohibited

Page 2: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Longitudinal stiffeners shall be proportioned so that(a) the stiffener width-to-thickness ratio does not exceed 200/ unless the section properties are

deemed to be based on an effective width of 200/ ;

(b) the projecting stiffener width is less than or equal to 30t ;

(c) I hw3(2.4(a/h)2 – 0.13); and

(d)

where I and r are calculated about a centroidal axis parallel to the web for a section comprising the stiffener or stiffeners and a strip of web 10w wide on each side.

10.10.7.3 Transverse stiffener requirements for longitudinally stiffened websTransverse stiffeners for girder panels with longitudinal stiffeners shall meet the requirements of Clause 10.10.6. In addition, the section modulus of the transverse stiffener, where I is calculated with respect to the base of the stiffener, shall not be less than St = hSh / 3a.

When j is calculated for the purpose of calculating the required moment of inertia, I , of the transverse stiffener in accordance with Clause 10.10.6.2(a), the depth of subpanel, hp , shall be used for calculating h/a.

When Clause 10.10.6.2(b) is applied to longitudinally stiffened girders, the depth of subpanel, hp , shall be used for calculating a/h in the equation for As ; the full depth of the web, h, shall be used for calculating C and Vr .

10.10.8 Bearing stiffeners

10.10.8.1 Web crippling and yieldingBearing stiffeners shall be provided where the factored concentrated loads or reactions at the ULS exceed the factored compressive resistance of the webs of beams or girders. The factored compressive resistance of the web, Br , shall be calculated as follows:(a) for concentrated loads applied at a distance from the member end greater than the member depth,

the lesser of(i) Br = bi w (N + 10t )Fy

(ii) Br =

where

bi = 0.80

N = length of bearing, mm

t = flange thickness, mm

(b) for end reactions, the lesser of(i) Br = be w (N + 4t )Fy

(ii) Br =

where

be = 0.75

N = length of bearing, mm

t = flange thickness, mm

Fy

Fy

r aFy≥

1900

1 45 2. fbi y sw F E

0 60 2. fbe y sw F E

461(Replaces p. 461, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 3: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.10.8.2 Bearing resistance and detailsBearing stiffeners shall extend the full depth of the web and shall be fitted to bear against the flange through which the loads are transmitted or be connected to the flange by welds. Stiffeners shall preferably be symmetrical about the web and extend as close to the edge of the flanges as practicable.

The width-to-thickness ratio of bearing stiffeners shall not exceed 200/ Fy .

The factored bearing resistance of the bearing stiffeners, Br , shall be calculated as

Br = 1.50 s As Fy

where

As = area of stiffener in contact with the flange, mm2

Fy = yield stress of the stiffener or flange, MPa, whichever is less

10.10.8.3 Compressive resistanceBearing stiffeners shall be designed as compression members in accordance with Clause 10.9, assuming a column section comprising all of the projecting stiffener element plus a strip of web extending not more than 12w on both sides of each stiffener element. The effective column length shall be taken as not less than 0.75 times the depth of the girder. Connections shall be designed for the interface force transmitted from the web to the stiffeners.

10.10.9 Lateral bracing, cross-frames, and diaphragms

10.10.9.1 Intermediate cross-frames or diaphragmsThe spacing of intermediate cross-frames or diaphragms shall be determined from an investigation of the lateral torsional buckling resistance of the longitudinal girders, the need to transfer lateral wind forces, and the need to provide torsional restraint to the girders for any anticipated applied torsional loading.

Cross-frames and diaphragms shall be designed for the lateral loads they are required to resist plus a lateral load equivalent to 1% of the compression flange force in the beam or girder at the location under consideration.

If the intermediate cross-frames or diaphragms are included in the structural model used to determine the forces in the girders, they shall be designed for the forces that they attract.

Intermediate cross-frames shall be placed normal to the main members when the supports are skewed more than 20° and shall be designed for the forces they attract.

Where girders support deck slabs proportioned in accordance with the empirical design method of Clause 8.18.4, the spacing of intermediate cross-frames, ties, or diaphragms shall satisfy the requirements of Clause 8.18.5.

10.10.9.2 Lateral BracingIf lateral loads are not resisted by the girders alone, a lateral bracing system shall be provided at or close to either the top or bottom flanges. Bracing systems shall be designed to resist a lateral load equivalent to at least 1% of the compression flange force in the beam or girder at the location under consideration, in addition to other applied forces for the limit state under consideration. The bracing system shall have sufficient stiffness to maintain the stability of the braced flange when the system has displaced, at the location under consideration, through the distance required to develop the bracing resistance. A steel or concrete deck used for this function shall be rigidly connected to the compression flange. Timber floors shall not be considered to provide adequate lateral support unless the floor and fastenings are designed for this purpose.

Unless otherwise justified by analysis, girder spans longer than 50 m shall have a system of lateral bracing at or close to the bottom flange.

As required by Clause A5.1.6, lateral bracing systems shall be designed for the forces they attract in maintaining the compatibility of deformations of girders under vertical loading.

(Replaces p. 462, November 2006)462

Single user license only. S

torage, distribution or use on network prohibited

Page 4: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Figure 10.1Class 1 and 2 sections in positive moment regions

(See Clauses 10.11.5.2.1, 10.11.5.2.3, and 10.11.5.2.4.)

10.11.5.2.3 Plastic neutral axis in concreteWhen C1 is greater than C2 , the plastic neutral axis is in the concrete slab as shown in Figure 10.1(a), and the depth of the compressive stress block, a, shall be calculated as

aC A f

b fr r y

c e c=

−′

2

0 85

ff.

The factored moment resistance, Mr , of the section shall be calculated as

Mr = Cc ec + Cr er

whereCc = 0.85 c be a fc ‘

(a) Plastic neutral axis in the concrete slab

(b) Plastic neutral axis in the steel section

be

Ar

As

Cc

Cr

Ts

Compression zone

d

yt

yb

tc

Centre of gravity ofsteelsection

a

ds’

ec er

0.85fcfc’

tt

tb

h

Plastic neutral axis of compositesection

frfy

fsFy

be

Ar

Asd

ytc

ybc

tc

Cc

Cr

Ts

ecer

frfy

fsFy

Cs

fsFy es

ds’0.85fcfc’

yt’

yb’

465(Replaces p. 465, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 5: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.11.5.2.4 Plastic neutral axis in steelWhen C1 is less than C2 , the plastic neutral axis is in the web as shown in Figure 10.1(b), and the depth of the compressive stress block, a, shall be taken as equal to tc . The factored moment resistance, Mr , shall be calculated as

Mr = Cc ec + Cr er + Cs es

where

Cc = 0.85 c betc fc‘

Cs = 0.5( s As Fy – C1)

10.11.5.3 Negative moment regions

10.11.5.3.1 Moment resistance of composite sectionWhen (a) shear connectors are provided; and (b) slab reinforcement is continuous over interior supports or the slab is prestressed longitudinally,the factored moment resistance, Mr , of the section shall be calculated on the basis of a fully plastic stress distribution in the structural steel, reinforcement, and prestressing strands, as shown in Figure 10.2, as follows:

Mr = Tr er + Ts es

where

Tr = r Ar fyTs = 0.5(s As Fy – Tr)

The requirements of Clause 8.5.3 shall also be satisfied.When shear connectors are not provided in the negative moment regions, the factored moment

resistance shall be taken as that of the steel section alone, calculated in accordance with Clause 10.10.2.

As

Ar

be

tc

d

Neutral axis

yb

er

Cs

es

yt’

frfy

Tr

Ts

fsFy

fsFy

Figure 10.2Class 1 and 2 sections in negative moment regions

(See Clause 10.11.5.3.1.)

(Replaces p. 466, November 2006)466

Single user license only. S

torage, distribution or use on network prohibited

Page 6: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.11.5.3.2 Longitudinal reinforcement in non-prestressed slabsWhen the longitudinal tensile stress in non-prestressed deck slabs at SLS exceeds c fcr , the longitudinal reinforcement, including longitudinal distribution reinforcement, shall not be less than 1% of the cross-sectional area of the slab. At least two-thirds of this reinforcement shall be placed in the top layer of the slab reinforcement and within the effective width of the slab.

10.11.5.3.3 Negative moment regions without shear connectorsWhen shear connectors are not provided in the negative moment region, the longitudinal reinforcement shall be extended into the positive moment regions in accordance with Clause 8.15, and additional shear connectors shall be provided in accordance with Clause 10.17.2.7.

10.11.6 Class 3 sections

10.11.6.1 Width-to-thickness ratiosThe portions of the steel section in compression shall comply with Clause 10.9.2.

10.11.6.2 Positive moment regions

10.11.6.2.1 Moment resistanceFor composite sections in which the depth of the compression portion of the web of the steel section,

calculated on the basis of a fully plastic stress distribution, equals or is less than 850w/ Fy , the factored

moment resistance shall be determined in accordance with Clause 10.11.5.2.

10.11.6.2.2 Moment resistance of slender membersWhen the depth of the compression portion of the web of the steel section, calculated in accordance with

Clause 10.11.6.2.1, exceeds 850w/ Fy , the factored moment resistance, Mr , of the composite section

shall be calculated on the basis of fully plastic stress blocks, as shown in Figure 10.3, as follows:

Mr = Cc ec + Cr er + Cs es

where

Cc = 0.85c betc fc‘

Cr = r Ar fyCs = s A‘sc Fy

The area of the steel section in compression, A‘sc , shall include the top flange and a web area of

(850w 2)/ Fy , and the area of the steel section in tension, A‘st , shall be calculated as follows:

′ =+ +

AC C C

Fstc r s

s yf

467(Replaces p. 467, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 7: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

850 w/ Fy

d

ttyt

yb

fsFy

frfybe

Ar

As

w

tc

Cr

Cc

Ts

Cs

erec

es

0.85fcfc’

S6S1-10 © Canadian Standards Association

May 2010

Figure 10.3Class 3 Sections in positive moment regions

(See Clause 10.11.6.2.2.)

10.11.6.3 Negative moment regions

10.11.6.3.1 Composite sections

10.11.6.3.1.1 When(a) shear connectors are provided; and (b) slab reinforcement is continuous over interior supports or the slab is prestressed longitudinally,the factored moment resistance of the composite section shall be taken as the resultant moment based on the linear stress distribution at first yielding or buckling, as shown in Figure 10.4, and the requirements specified in Clause 10.11.6.3.1.2 shall be satisfied.

10.11.6.3.1.2 The following requirements shall be satisfied:(a) Mfd /S + (Mfsd + Mfl )/S‘ sFcr

where S and S‘ are the elastic section moduli with respect to the bottom fibre, Fcr = Mr /sS, and Mr is determined in accordance with Clause 10.10.3.3, based on the steel section.

(b) Mfd /S + (Mfsd + Mfl )/S‘ sFy

where S and S‘are the elastic section moduli with respect to the top fibre of the steel section.

(c) (Mfsd + Mfl )/S‘ rfywhere S‘ is the elastic section modulus with respect to the centroid of the top layer of longitudinal slab reinforcement.

The applicable requirements of Clauses 8.5.3 and 10.11.5.3.2 shall also be satisfied.

(Replaces p. 468, November 2006)468

Single user license only. S

torage, distribution or use on network prohibited

Page 8: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

+ =

Dead load onbare steel girder

Superimposed dead plus liveload on composite girder

Total accumulatedstresses

SMfd

SMfsd + Mfl

< fsFcr

fsFy

frf y

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Figure 10.4Class 3 Sections in negative moment regions

(See Clause 10.11.6.3.1.)

10.11.6.3.2 Non-composite sectionsWhen shear connectors are not provided in the negative moment regions, the factored moment resistance shall be taken as that of the steel section alone, calculated in accordance with Clause 10.10.3. The requirements of Clause 10.11.5.3.3 shall also be satisfied.

10.11.7 Stiffened plate girders

10.11.7.1 Width-to-thickness ratiosStiffened plate girders shall meet the requirements of Clauses 10.10.4.1 and 10.10.4.2.

10.11.7.2 Positive moment regions

10.11.7.2.1 Moment resistanceFor composite sections in which the depth of the compression portion of the web of the steel section, calculated on the basis of a fully plastic stress distribution, does not exceed 850w/ Fy , the factored moment resistance shall be determined in accordance with Clause 10.11.5.2.

10.11.7.2.2 Moment resistance of slender websWhen the depth of the compression portion of the web of the steel section calculated in accordance with

Clause 10.11.7.2.1 exceeds 850w/ Fy , whether or not longitudinal stiffeners are provided, the factored

moment resistance of the composite section shall be calculated on the basis of fully plastic stress blocks, as

in Clause 10.11.6.2.2.

469(Replaces p. 469, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 9: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.11.7.3 Negative moment regions

10.11.7.3.1 Composite sectionsWhen (a) shear connectors are provided; and(b) slab reinforcement is continuous over interior supports or the slab is prestressed longitudinally,the factored moment resistance of the section shall be calculated in accordance with Clause 10.11.6.3.1.

If longitudinal stiffeners are not provided and 2dc /w > 1900 Fy , the factored moment resistance shall be reduced by the factor specified in Clause 10.10.4.3.

10.11.7.3.2 Non-composite sectionsWhen shear connectors are not provided in the negative moment region, the factored moment resistance shall be taken as that of the steel section alone (see Clause 10.10.4). The requirements of Clause 10.11.5.3.3 shall also apply.

10.11.8 Shear connectors

10.11.8.1 GeneralShear connectors shall comply with the applicable materials specification of Clause 10.4 and shall be capable of resisting both horizontal and vertical movements between the concrete slab and the steel beam or girder.

The fatigue resistance of the base metal at the connection weld of shear connectors shall meet the requirements of Clause 10.17.2.3. The fatigue resistance of stud shear connectors shall meet the requirements of Clause 10.17.2.7.

10.11.8.2 Cover and edge distancesThe clear depth of concrete cover over the top of shear connectors shall meet the requirements of Clause 8.11.2.2. Shear connectors shall extend into the concrete deck so that the clear distance from the underside of the head of the shear connector to the top of the bottom transverse reinforcement or, when the slab is haunched, to the top of the transverse reinforcement in the slab haunch, is at least 25 mm. The clear distance between the edge of a girder flange and a shear connector shank shall be at least 25 mm.

10.11.8.3 Resistance, placement, and spacingIn determining the resistance of shear connectors, connector strength and spacing, concrete strength and, where stud connectors are embedded in grout, grout strength, including grout side cover to the studs, shall be taken into consideration. Use of connectors that are fastened to the steel section by means other than welding shall require Approval.

The minimum number of shear connectors in each shear span shall be calculated as follows:

N = P/qr

where a shear span is a segment between points of maximum and zero moment at the ULS and P is determined as follows:(a) for positive moment:

(i) when the plastic neutral axis is in the concrete slab: P = sAsFy ; and(ii) when the plastic neutral axis is in the steel section: P = 0.85cfc’ betc + r Arfy ; and

(b) for negative moment: P = r Arfy .The factored shear connector resistance, qr , shall be determined in accordance with Clauses 10.11.8.3.1

to 10.11.8.3.3.

10.11.8.3.1 Stud connectors in cast-in-place deck slabThe factored shear resistance, qr , of a headed stud shear connector with h/d 4 shall be taken as

q A f E F Ar sc sc c c sc u sc= ′ ≤0 5. f f

(Replaces p. 470, November 2006)470

Single user license only. S

torage, distribution or use on network prohibited

Page 10: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

where

Fu = minimum tensile strength of the stud steel (450 MPa for CSA W59 Type B studs)

Asc = cross-sectional area of one stud shear connector, mm2

The spacing of shear connectors shall not be less than 4d, nor greater than 600 mm. Stud connectors shall be spaced uniformly in a shear span or spaced according to the variation in the interface shear.

10.11.8.3.2 Stud connectors in full-depth precast panelsThis Clause applies to full-depth precast panels where grout pockets (blockouts) are provided to accommodate clusters of stud connectors welded to the steel section. The pockets are filled with non-shrink grout to provide composite action.

The grout pockets shall be shaped to prevent vertical separation between the deck slab and the steel section unless other means of interlocking are provided.

The concrete used in the precast panels shall have f’c 35 MPa and the compressive strength of the grout shall be equal to or greater than the f’c of the concrete. The precast panels shall meet all the requirements of Section 8. Local effects due to the actions of the studs shall also be considered. Post-tensioning, when specified, shall precede the grout placement.

The maximum spacing of stud clusters shall not exceed 1200 mm. The minimum spacing of studs within the pocket shall be 4d. The grout side cover, taken as the shortest distance from the grout pocket perimeter to the shank of the nearest stud, shall be greater than or equal to 1.5d.

The factored resistance of a stud shear connector, qr , shall be determined in accordance with Clause 10.11.8.3.1. In this calculation, the values for f’c and Ec shall be based on the compressive strength of the grout. The grout strength shall not be greater than 1.3 times the f’c of the precast concrete. Where the stud cluster spacing exceeds 600 mm, the minimum number of studs per cluster shall vary according to the variation in the interface shear.

The use of stud connectors 25 mm in diameter or larger shall require Approval.

10.11.8.3.3 Channel connectors in cast-in-place deck slabIn solid slabs of normal-density concrete, the factored shear resistance for channel shear connectors shall be taken as

q t w L fr sc c c= +( ) ′45 0 5f .

where

t = average thickness of channel shear connector flange, mm

w = thickness of channel shear connector web, mm

Lc = length of channel shear connector, mm

Channel connectors shall be spaced according to the variation in the interface shear.

10.11.8.4 Longitudinal shearThe longitudinal factored shear resistance along any potential shear planes shall be greater than the factored longitudinal shear.

The factored longitudinal shear in the slab of a composite beam, Vu , shall be taken as

For normal-weight concrete, the factored shear resistance along any potential shear surface in the concrete slab shall be calculated as

For lightweight concrete, the constant 2.76 with units of MPa shall be replaced by 1.38.

V q A f A fu r c c c r rL y= − ′ −S 0 85. f f

V A f A A fr r rt y c cv c cv c= + ≤ ′0 80 2 76 0 50. . .f f f

471(Replaces p. 471, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 11: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.11.9 Lateral bracing, cross-frames, and diaphragmsThe requirements of Clause 10.10.9 shall be met.

10.12 Composite box girders

10.12.1 GeneralClause 10.12.1 applies to the design of simple and continuous composite box girder bridges of spans up to 110 m, consisting of one or more straight steel single-cell box girders, acting compositely with a concrete deck, and symmetrical about a vertical axis. For longer spans, other requirements may apply.

The top of the box may be open with twin steel flanges or closed with a steel flange plate.Exterior access holes with hinged and locked doors shall be provided. Openings in box sections shall be

screened to exclude animals.The requirements of Clauses 10.11.2 to 10.11.4 shall also apply.

10.12.2 Effective width of tension flangesThe effective width of bottom flange plates in tension shall be taken as not more than one-fifth of the span for simply supported structures and not more than one-fifth of the distance between points of contraflexure under dead load for continuous structures.

10.12.3 Web platesWebs shall be proportioned in accordance with Clause 10.10 and, for single box girders, in accordance with Clause 10.12.8.5. The shear force to be considered on each web shall be Vf /cos , where Vf is one-half of the total vertical shear force at the ULS on one box girder and is the angle of inclination of the web plate to the vertical.

The inclination of the web plates shall not exceed 1 horizontal to 4 vertical.

10.12.4 Flange-to-web weldsThe total effective throat of the flange-to-web welds shall not be less than the thickness of the web unless internal diaphragms or cross-frames are spaced in accordance with Clause 10.12.6.1 and a minimum of two intermediate diaphragms per span are used inside the box. If fillet welds are used, they shall be placed on both sides of the connecting flange or web plate.

10.12.5 Moment resistance

10.12.5.1 Composite and non-composite sections

10.12.5.1.1 The factored moment resistance of the steel section acting alone before the attainment of composite action shall be determined in accordance with(a) Clauses 10.10, 10.12.2, and 10.12.8.4 for regions of positive moment; and(b) Clauses 10.10 and 10.12.5.2 to 10.12.5.4 for regions of negative moment, using the elastic section

modulus of the steel section alone.

10.12.5.1.2 The factored moment resistance of the composite section shall be determined in accordance with (a) Clauses 10.11, 10.12.2, and 10.12.8.4 for regions of positive moment; and(b) Clause 10.11 for regions of negative moment, except that in applying Clause 10.11.6.3.1.1

or 10.11.6.3.1.2, Fcr shall be determined in accordance with the applicable requirements of Clauses 10.12.5.2 to 10.12.5.4.

(Replaces p. 472, November 2006)472

Single user license only. S

torage, distribution or use on network prohibited

Page 12: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.12.5.2 Unstiffened compression flanges The factored moment resistance with respect to the compression flange shall be calculated as follows:(a) when b/t 510/ :

Mr = sFyS‘

(b) when 510/ < b/t 1100/ :

Mr = sFcrS‘

where

Fcr =

where

C =

(c) when b/t > 1100/ :

Mr = sFcrS‘

where

Fcr =

10.12.5.3 Compression flanges stiffened longitudinally

10.12.5.3.1 The factored moment resistance with respect to the compression flange shall be calculated as follows:(a) when :

Mr = sFyS‘

(b) when :

Mr = sFcrS‘

Fy

Fy Fy

0 592 1 0 6872

. . sinFC

y +⎡⎣⎢

⎤⎦⎥

π

1100

590

− ( / )b t Fy

Fy

7 24 105

2.( / )

×b t

b t k Fs y/ /≤ 255 1

255 5501 1k F b t k Fy s y/ / /< ≤

472A

Single user license only. S

torage, distribution or use on network prohibited

Page 13: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Single user license only. S

torage, distribution or use on network prohibited

Page 14: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

where

Fcr =

where

Cs =

(c) when :

Mr = sFcrS‘

where

Fcr =

10.12.5.3.2 The buckling coefficient, k1, in Clause 10.12.5.3.1 shall be determined as follows:(a) For n = 1:

(b) For n > 1:

wheren = number of longitudinal stiffeners

Is = moment of inertia of each stiffener about an axis parallel to the flange and at the base of the stiffener, mm4

10.12.5.3.3 The longitudinal stiffeners shall be equally spaced across the flange width. A transverse stiffener shall be placed near the point of contraflexure under dead load and shall be equal in size to a longitudinal stiffener.

10.12.5.4 Compression flanges stiffened longitudinally and transverselyThe factored moment resistance with respect to the compression flange shall be calculated as follows:

(a) when :

Mr = sFyS‘

(b) when :

Mr = sFcrS‘

where

Fcr =

0 592 1 0 6872

. . sinFC

ys+⎡

⎣⎢⎤⎦⎥

π

550

2951

1

k b t F

ks y− ( / )

b t k Fs y/ /> 550 1

18 1014

2kb ts

×( / )

kI

b ts

s1 3

1 38

4 0=⎡

⎣⎢⎢

⎦⎥⎥

≤/

.

kI

b t ns

s1 3 4

1 314 3

4 0=⎡

⎣⎢⎢

⎦⎥⎥

≤.

./

b t k Fs y/ /≤ 255 2

255 5502 2k F b t k Fy s y/ / /< ≤

0 592 1 0 6872

. . sinFC

ys+⎡

⎣⎢⎤⎦⎥

π

473(Replaces p. 473, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 15: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

where

Cs =

(c) when :

Mr = sFcrS‘

where

Fcr =

k2 =

The longitudinal stiffeners shall be equally spaced across the flange width and shall be proportioned so that the moment of inertia of each stiffener, Is, about a transverse axis at the base of the stiffener is at least equal to

Is = 8t3bs

The transverse stiffeners shall be proportioned so that the moment of inertia of each stiffener, It, about a longitudinal axis through its centroid is at least equal to

I n bF AE at scr f

s= +0 55 1 3 3. ( )

The ratio a/b shall not exceed 3.0. The maximum value of the buckling coefficient k2 shall be 4.0. When k2 has its maximum value, the transverse stiffeners shall have a spacing, a, equal to or less than 4bs. The transverse stiffeners need not be connected to the flange plate but shall be connected to the webs of the box and to each longitudinal stiffener. The connection to the web shall be proportioned for a vertical force, Rw , of

RF S

bws y t=

f2

The connection to each longitudinal stiffener shall be proportioned for a vertical force, Rs , of

RF S

nbss y t=

f

10.12.6 Diaphragms, cross-frames, and lateral bracing

10.12.6.1 Diaphragms and cross-frames within girdersInternal diaphragms, cross-frames, or other means shall be provided at each support to resist transverse rotation, displacement, and distortion and to transfer vertical, transverse, and torsional loads to the bearings. The effect of access holes shall be considered and adequate reinforcement provided if necessary.

Intermediate internal diaphragms or cross-frames shall be used to control deformation, torsional warping, and distortion of open box girders during fabrication, transportation, erection, and placement of the deck. Cross-frames, diaphragms, or cross-ties between top flanges shall be used in open trapezoidal box girders to resist the transverse resultant induced by the sloping web force opposing the vertical loads acting on the top flanges during construction.

550

2952

2

k b t F

ks y− ( / )

b t k Fs y/ /> 550 2

18 1024

2kb ts

×( / )

[ ( / ) ] .

( ) ( / ) [ . ( )]

1 87 3

1 1 0 1 1

2 2

2 2

+ ++ + +

a b

n a b n

(Replaces p. 474, November 2006)474

Single user license only. S

torage, distribution or use on network prohibited

Page 16: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.13.2.2 Super-elevation and centrifugal forcesThe super-elevation of the deck shall be considered when the wheel loads due to the combined effects of the centrifugal forces and the vertical live loads are being determined.

10.13.2.3 Thermal forcesTangential and radial movements, potential uplift at the bearings, and induced restraining forces due to the temperature changes and gradients shall be taken into account.

10.13.2.4 UpliftThe structure shall be assessed for uplift at the supports. The assessment for dead loads shall take into account the intended sequence of construction.

10.13.3 Design theory

10.13.3.1 GeneralThe whole structure shall be modelled in the analysis, including the transverse members. The analysis shall include, in addition to the torsional shear stresses, an evaluation of the longitudinal stresses due to restrained warping of members with non-uniform torsion.

10.13.3.2 Limiting curvatureProvided that the conditions of Clause A5.1.3.2 are met, the bridge shall be considered straight for the purposes of structural analysis.

10.13.4 BearingsBearings shall be designed to resist the vertical loads (including uplift) and the horizontal loads to which they could be subjected (including centrifugal force effects) and be designed and oriented to permit thermal movement consistent with the design assumptions.

10.13.5 Diaphragms, cross-frames, and lateral bracingUnless otherwise Approved, longitudinal girders shall be connected at each support by diaphragms designed to prevent twisting of the girders.

Diaphragms or cross-frames shall be provided between I-girders, i.e., at intervals between supports, to further facilitate resistance to twisting of the girders. Each line of diaphragms or cross-frames shall extend continuously across the full width of the bridge.

Diaphragms or cross-frames shall be provided between box girders where needed to augment the resistance of the girders to torsion. Diaphragms or cross-frames shall be provided inside the girders in line with those provided between the girders.

Diaphragms and cross-frames shall be treated as main structural members. They shall be approximately as deep as the girders they connect and shall be connected to the girders to transfer all of the loads that they attract.

In addition to the diaphragms or cross-frames used to control torsion, other cross-frames shall be provided in box girders, if necessary, to resist the distortional effects of eccentric loads on the cross-section.

The need for lateral bracing between the top flanges of curved box girders and between I-girders to ensure stability and resist the effects of wind shall be assessed for all stages of construction as well as for service conditions.

Where girders support deck slabs proportioned in accordance with the empirical design method of Clause 8.18.4, the lateral spacing of intermediate cross-frames or diaphragms shall satisfy the requirements of Clause 8.18.5.

477(Replaces p. 477, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 17: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.13.6 Steel I-girders

10.13.6.1 Non-composite girder design

10.13.6.1.1 Limits of applicabilityThe following requirements shall apply:(a) The absolute value of the ratio of the torsional warping normal stress to the normal flexural stress

shall, as far as possible, not exceed 0.5 at any point in the girder.(b) The unbraced length between cross-frames shall not exceed 25 times the width of the flange or

0.1 times the mean radius of the girder.(c) Flanges shall be Class 3 or better.

10.13.6.1.2 FlangesFlanges shall be proportioned to satisfy the following requirements:

MM

MM

fx

rx

fw

ry+ < 1

(a) Strength of either flange:

(b) Stability of compression flange:

Mfx M‘rx

where

Mfx = factored bending moment due to flexure

Mrx = sF ySx

where

Sx = elastic section modulus of the girder about its major axis

Mfw = factored bending moment in the flange due to torsional warping

Mry = sF ySy

where

Sy = elastic section modulus of the flanges only about an axis in the plane tangent to the web of the girder

M‘rx = sFy Sx (1 – 3 2) b w

where

=

b =

w = smaller of w1 and w2 when fw / fb is positive

= w1 when fw / fb is negative

Lb

F

Ey

s2 2π

1

12

+ ⎡⎣⎢

⎤⎦⎥

⎡⎣⎢

⎤⎦⎥

LR

Lb

(Replaces p. 478, November 2006)478

Single user license only. S

torage, distribution or use on network prohibited

Page 18: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

where

w1 =

w2 =

fw = coexisting warping normal stress, MPa

fb = flexural stress due to the larger of the two moments at either end of the braced segment, MPa

fw / fb is positive when fw is compressive on the outside edge of the curved flange.

10.13.6.1.3 WebsThe factored shear resistance shall be calculated in accordance with Clause 10.10.5.1(a) (neglecting tension field action). The following requirements shall also apply:(a) Webs without stiffeners: transverse stiffeners shall not be required if h/w 150.(b) Webs with transverse stiffeners only: when

150 < h/w

transverse stiffeners shall be provided at a spacing a < h.(c) Webs with transverse and longitudinal stiffeners: when

< h/w <

the longitudinal stiffeners shall be provided at a distance 0.2h from the compression flange.When same-size longitudinal stiffeners are located 0.2h from both the compression flange and the

tension flange, the web slenderness ratio shall not exceed 6000/ .

(d) Proportioning of transverse web stiffeners: in addition to meeting the b/t requirements of Clause 10.9.2, stiffeners shall be proportioned so that

I aw3j

where

j =

where

X = 1.0 when

=

I shall be taken about an axis at the mid-plane of the web for stiffener pairs, or at the near face of the web for single stiffeners.

1

1 1150

− −⎡⎣⎢

⎤⎦⎥

ff

Lb

w

b

0 95 2

30 8000 0 1

1 0 6

2.

.

.

++ −⎡

⎣⎢⎤⎦⎥

+⎡

⎣⎢

⎦⎥

Lb

LR

ffw

b

31501 8 6 34

2

F

aR

aRy

− ⎡⎣⎢

⎤⎦⎥

+ ⎡⎣⎢

⎤⎦⎥

⎣⎢⎢

⎦⎥⎥

.

31501 8 6 34

2

F

aR

aRy

− ⎡⎣⎢

⎤⎦⎥

+ ⎡⎣⎢

⎤⎦⎥

⎣⎢⎢

⎦⎥⎥

.6000

1 2 9 2 20 5

F

aR

aRy

− ⎡⎣⎢

⎤⎦⎥

+ ⎡⎣⎢

⎤⎦⎥

⎣⎢⎢

⎦⎥⎥

. ..

Fy

2 5 2 0 52

. .ha

X⎡⎣⎢

⎤⎦⎥

−⎡

⎣⎢⎢

⎦⎥⎥

ah

≤ 0 78.

1 00 78

17750 78 1 0 0 10 0 94.

.. . , , .+

−⎡⎣⎢

⎤⎦⎥ < < ≤ ≤ =

ah Z

ah

Z Z when and 552a

Rw

479(Replaces p. 479, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 19: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

(e) Longitudinal stiffeners shall meet the requirements of Clause 10.10.7.2.(f) Monosymmetric sections: the slenderness ratio of the compression portion of webs of

monosymmetric sections with an axis of symmetry in the plane of loading shall not exceed one-half of the applicable value specified in Item (a), (b), or (c).

Longitudinal stiffeners, if required, shall be placed 0.4dc from the inner surface of the compression flange.

10.13.6.2 Composite I-girders

10.13.6.2.1 GeneralClauses 10.13.6.2.2 to 10.13.6.2.4 shall apply to simple and continuous span curved I-girders, fastened throughout their full length to a concrete deck by shear connectors.

10.13.6.2.2 WebsThe web of the steel girder shall be designed to carry the entire vertical shear in accordance with Clause 10.13.6.1.3.

10.13.6.2.3 FlangesFlanges shall be Class 3 or better and meet the strength and stability requirements of Clause 10.13.6.1.2.

10.13.6.2.4 Shear connectorsShear connectors shall meet the requirements of Clauses 10.11.8 and 10.17.2.7.

10.13.7 Composite box girders

10.13.7.1 GeneralClause 10.13.7.1 shall apply to simple or continuous span curved box girders fastened throughout their length to a concrete deck by shear connectors.

The behaviour of a girder before the concrete deck has cured may be analyzed as a quasi-closed section by replacing the lateral bracing with an equivalent plate. The top flanges shall meet the requirements of Clause 10.13.6.2.3 and the bottom flange shall meet the requirements of Clause 10.13.7.4.

10.13.7.2 WebsThe inclination of the webs from the normal to the bottom flange shall not exceed 1 in 4. The webs shall meet the requirements of Clause 10.13.6.1.3 for combined flexural and torsional shear.

10.13.7.3 Top flangesThe top flanges of open-box girders shall meet the requirements of Clauses 10.13.6.1.1 and 10.13.6.1.2 and the top flanges of closed-box girders shall meet the requirements of Clause 10.13.7.4. In both cases, lateral bending and buckling of the steel flange shall be checked for strength and stability during placement of concrete, but may be assumed to be restrained by the concrete deck when the deck has cured.

10.13.7.4 Bottom flanges

10.13.7.4.1 Tension flangesThe factored moment resistance with respect to the tension flange shall be determined using an effective width in accordance with Clause 10.12.5.1.2(a) and using a reduced normal stress, Rv F y , in place of Fy , with Rv as follows:

(Replaces p. 480, November 2006)480

Single user license only. S

torage, distribution or use on network prohibited

Page 20: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Single groove butt weld on permanentbacking bar. Backing bar fillet weldscontinuous.

Preferably no snipe in web

80%penetration

80%penetration

(a) Welded longitudinal field splice of deck plate

Grind ends of welddo not wrap around

Note: c > h/3 (75 mm minimum).

50R

a e

c

h

(b) Intersection of closed ribs with floor beams

20R

Edge of sidewalk

20

(c) Open ribs at floor beams

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Figure 10.5Detailing requirements for orthotropic decks

(See Clause 10.16.6.3.)

10.16.7 Wearing surfaceThe wearing surface shall be considered an integral part of the orthotropic deck and shall be bonded to the top of the deck plate.

The contribution of a wearing surface to the stiffness of the members of an orthotropic deck shall not be considered unless the structural and bonding properties are satisfactorily demonstrated over the design temperature range. If the contribution is considered, the required engineering properties of the wearing surface shall be specified on the Plans.

487(Replaces p. 487, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 21: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

For the purpose of design, the following requirements shall apply:(a) the long-term composite action between the deck plate and the wearing surface shall be

demonstrated by both static and dynamic cyclic load tests;(b) the determination of force effects in the wearing surface and at the interface with the steel deck plate

shall take into account the engineering properties of the wearing surface at anticipated extreme service temperatures; and

(c) the wearing surface shall be assumed to act compositely with the deck plate whether or not the deck plate is designed on that basis.

10.17 Structural fatigue

10.17.1 GeneralThe FLS considered shall include direct live load effects, i.e., live load-induced fatigue, and the effects of local distortion within the structure, i.e., distortion-induced fatigue.

10.17.2 Live-load-induced fatigue

10.17.2.1 Calculation of stress rangeThe stress range for load-induced fatigue shall be calculated using ordinary elastic analysis and the principles of mechanics of materials. A more sophisticated analysis shall be required only in cases not covered in Tables 10.7 and 10.8, such as major access holes and cutouts. Because the stress range shall be the algebraic difference between the maximum stress and minimum stress at a given location, only the stresses due to live load shall be considered.

At locations where the stresses resulting from the permanent loads are compressive, load-induced fatigue shall be disregarded when the compressive stress is at least twice the maximum tensile live load stress.

10.17.2.2 Design criteriaFor load-induced fatigue, except in bridge decks, each detail shall satisfy the requirement that

0.52CLfsr < Fsr

where

CL = 1.0, except when W > 625 kN and the volume of heavy trucks prompting the use of a level of loading greater than that for CL-625 Trucks constitutes not more than the greater of 200 per day and 5% of the ADTT on the highway, CL = 0.20 + 500/W

fsr = calculated fatigue stress range at the detail due to passage of the CL-W Truck, as specified in Clause 3.8.3.2

For load-induced fatigue in bridge decks, each detail shall satisfy the requirement that

0.62fsr Fsr

where

fsr = calculated fatigue stress range at the detail due to passage of a tandem set of 125 kN axles spaced 1.2 m apart and with a transverse wheel spacing of 1.8 m

10.17.2.3 Fatigue stress range resistance

10.17.2.3.1 Fatigue stress range resistance of a member or detailThe fatigue stress range resistance of a member or a detail, Fsr , other than for shear studs or cables, shall be calculated as follows:

Fsr = (/Nc )1/3 Fsrt / 2

(Replaces p. 488, November 2006)488

Single user license only. S

torage, distribution or use on network prohibited

Page 22: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

where

= fatigue life constant pertaining to the detail category established in accordance with Clause 10.17.2.4 and specified in Table 10.4

Nc = 365y Nd (ADTTf)

where

y = design life (equal to 75 years unless otherwise specified by the Owner or Engineer)

Nd = number of design stress cycles experienced for each passage of the design truck, as specified in Table 10.5

ADTTf = single-lane average daily truck traffic, as obtained from site-specific traffic forecasts. In lieu of such data, ADTTf shall be estimated as p (ADTT), where p is 1.0, 0.85, or 0.80 for the cases of one, two, or three or more lanes available to trucks, respectively, and ADTT is as specified in Table 10.6

10.17.2.3.2 Fatigue stress range resistance of fillet welds transversely loadedThe fatigue stress range resistance, Fsr , of fillet welds transversely loaded shall be calculated as a function of the weld size and plate thickness, as follows:

Fsr = Fsrc [(0.06 + 0.79D/t)/(0.64t1/6)]

where

Fsrc = fatigue stress range resistance for Category C, as determined in accordance with

Clause 10.17.2.3.1, based on no penetration of the weld root

D = weld leg size, mm

t = plate thickness, mm

Table 10.4Fatigue life constants and constant amplitude threshold stress ranges

(See Clauses 10.17.2.3.1 and 13.8.17.7.3.)

Detail categoryFatigue life constant,

Constant amplitudethreshold stress range,Fsrt, MPa

ABB1CC1DEE1M164M253

8190 × 109

3930 × 109

2000 × 109

1440 × 109

1440 × 109

721 × 109

361 × 109

128 × 109

561 × 109

1030 × 109

165110836983483118

214262

489(Replaces p. 489, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 23: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

Table 10.5Values of Nd

(See Clause 10.17.2.3.1.)

Table 10.6Average daily truck traffic

(See Clause 10.17.2.3.1.)

10.17.2.4 Detail categoriesThe detail categories shall be as specified in Tables 10.7 and 10.8.

The following details shall be prohibited for use when cyclic loading is present:(a) partial penetration groove welds loaded transversely; and(b) cover plates attached to girder flanges using only fillet welds that are oriented transversely with

respect to the direction of stress in the member.

10.17.2.5 Width-to-thickness ratios of transversely stiffened websThe width-to-thickness ratios of transversely stiffened webs, h/w, shall not exceed 3150/ Fy unless a longitudinal stiffener is provided in accordance with Clause 10.10.7.

In determining a width-to-thickness ratio, Fy may be replaced by the maximum compressive stress due to the factored ULS loads if the maximum shear at the FLS does not exceed Vr calculated in accordance with Clause 10.10.5.1, taking Ft = 0 and s = 1.0.

Longitudinal membersSpan length, L, 12 m

Span length, L, < 12 m

Simple-span girdersContinuous girders

Near interior support (within 0.1L on either side)All other locations

Cantilever girdersTrusses

1.0

1.5

1.05.01.0

2.0

2.0

2.05.01.0

Transverse members Spacing 6 m Spacing < 6 m

All cases 1 2

Class of highway ADTT

ABCD

4000100025050

(Replaces p. 490, November 2006)490

Single user license only. S

torage, distribution or use on network prohibited

Page 24: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Table 10.8 (Concluded)

10.17.2.6 Fatigue resistance of high-strength bolts loaded in tensionHigh-strength bolts subjected to tensile cyclic loading shall be pretensioned to the minimum preload specified in Clause 10.24.6.3. Connected parts shall be arranged so that prying forces are minimized. The calculated prying force shall not exceed 30% of the externally applied load.

10.17.2.7 Fatigue resistance of stud shear connectorsStud shear connectors shall be designed for the following stress range, rs :

whereCL = 1.0, except when W > 625 kN and the volume of heavy trucks prompting the use of a level of

loading greater than that for CL-625 Trucks constitutes not more than the greater of 200 per day and 5% of the ADTT on the highway, CL = 0.20 + 500/W

Vsc = design shear force at the section along the length of the beam where the fatigue resistance of the shear connectors is being evaluated, N

Q = first moment of area of the transformed section at the interface between the concrete slab and the steel section, mm3

s = shear stud group spacing, mmAsc = cross-sectional area of a shear stud, mm2

n = number of shear studs in the group at the cross-section being evaluatedIt = moment of inertia of the transformed composite section about the axis of bending, mm4

Fatigue Category D shall be used to evaluate the fatigue resistance of stud shear connectors.

Generalcondition Situation

Detailcategory

Illustrativeexample

Welded rib splice without backing bar

Single-groove butt weld without backing bar

E1

Rib intersection with floor beam

Axial stress in rib wall at the lower end of rib to floor beam weld

D

Deck plate to floor beam connection

Deck plate stress parallel to floor beam at deck to floor beam junction

D

Floor beam web at cutout

Vertical stress in floor beam web at floor beam cutout at the bottom of rib.f = stress in floor beam web due to bending moment, VHh, where VH = VLL+I (a + e) Q/I and Q and I are properties of the floor beam cross-section at Section 1-1.

D

Q e

VH

fh

1

1

t rs Lsc

sc tC

V QA I

sn

= 0 52.

499(Replaces p. 499, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 25: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

When stud shear connectors are not provided in negative moment regions, additional connectors, Na in number, shall be provided at each location of contraflexure, where

where

Zsr = the allowable range of interface shear in an individual shear connector, given as

where

Nc = number of cycles as specified in Clause 10.17.2.3

These additional connectors shall be placed within a distance equal to one-third of the effective slab width on each side of the point of dead load contraflexure.

10.17.2.8 Fatigue resistance of cables

10.17.2.8.1 Suspension cables and hangersCables and hangers used in suspension bridge construction need not be designed for fatigue, unless, in the judgment of the Engineer, special fatigue provisions are required.

10.17.2.8.2 Cable-stays and cable-stayed bridge tie-downs

10.17.2.8.2.1 Inspectable staysThe fatigue stress range for cable-stays and tie-downs that are replaceable without significant loss of function of the bridge, and in which wire breaks can be detected in service, shall not exceed the fatigue stress resistance established by test. An acceptable test is a test of cable and sockets in which the stress range is applied for 2 000 000 cycles and, at the end of which, the test stay has at least 0.95 of its specified breaking strength. The lowest stress range of three successful tests shall be taken as the fatigue stress range resistance.

For the purpose of this Clause, secondary (bending) stresses shall be calculated, but only secondary stresses exceeding 50 MPa shall be added to the primary (tension) stress to derive the test fatigue stress range.

10.17.2.8.2.2 Non-inspectable or non-replaceable staysThe fatigue stress range resistances for cable stays and tie-downs in which wire breaks cannot be detected while they are in service, or for cable stays and tie-downs that cannot be readily replaced, shall not exceed 0.75 of the fatigue stress range resistance established by test.

10.17.3 Distortion-induced fatigue

10.17.3.1 GeneralWhen members designed in accordance with Clause 10.17.2 for load-induced fatigue are provided with interconnection components such as diaphragms, cross-bracing, and lateral bracing, both the members and the interconnection components shall be examined for distortion-induced fatigue. Wherever practicable, elements of the primary member shall be fastened to the interconnection member unless otherwise Approved. The requirements for controlling web buckling and flexing of girder webs specified in Clause 10.17.3.2.2 shall apply.

N CA fZa Lr sr

sr= 0 52.

Z N A Asr c sc sc= ×( ) ≥721 10 249 13

(Replaces p. 500, November 2006)500

Single user license only. S

torage, distribution or use on network prohibited

Page 26: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.17.3.2 Connection of diaphragms, cross-frames, lateral bracing, and floor beams

10.17.3.2.1 Connection to transverse elementsUnless otherwise Approved, the connections of diaphragms, including internal diaphragms, cross-frames, lateral bracing, floor beams, etc., to main members shall be made using transverse connection plates that are welded or bolted to both the tension and compression flanges of the main member. If transverse stiffeners of the main members form part of the connection, they shall be similarly connected.

In straight non-skewed bridges, the connections shall be designed to resist a factored horizontal force of 90 kN unless a more exact value is determined by analysis.

10.17.3.2.2 Connection to lateral elementsIf connections of diaphragms, including internal diaphragms, cross-frames, lateral bracing, floor beams, etc., are to be made to elements that are parallel to the longitudinal axis of the main member, the lateral connection plates shall be attached to both the tension and compression flanges of the main member. Where this is not practicable, then lateral connection plates shall be located as follows:(a) Transversely stiffened girders: where lateral connection plates are fastened to a transversely stiffened

girder, the attachment shall be located at a vertical distance not less than one-half the flange width from the flange. If located within the depth of the web, the lateral connection plate shall be centred with respect to the transverse stiffener, whether or not the stiffener and the connection plate are on opposite sides of the web. If the lateral connection plate and the transverse stiffener are located on the same side of the web, the plate shall be attached to the stiffener. Transverse stiffeners at locations where lateral connection plates are attached shall be continuous between the flanges and shall be fastened to them. Bracing members attached to the lateral connection plates shall be located so that their ends are at least 100 mm from the face of the girder web and the transverse stiffener.

(b) Transversely unstiffened girders: lateral connection plates may be fastened to a transversely unstiffened girder, provided that the attachment is located a vertical distance not less than one-half the flange width or 150 mm from the flange. Bracing members attached to the lateral connection plates shall be located so that their ends are at least 100 mm from the face of the girder web.

10.17.4 Orthotropic decksDistortion-induced fatigue shall be minimized through appropriate detailing in accordance with Clause 10.16.6. The stress ranges for live-load-induced fatigue shall be as specified in Clause 10.17.2.

10.18 Splices and connections

10.18.1 General

10.18.1.1 General design considerationsSplices and connections shall be designed at the ULS for the larger of(a) the calculated forces at the splice or connection; or(b) 75% of the factored resistance of the member, such resistance to be based on the condition of

tension, compression, bending, or shear that governed selection of the member.Except for handrails and non-load-carrying components, connections shall contain at least two 16 mm

diameter high-strength bolts or equivalent welds.

10.18.1.2 Alignment of axially loaded membersWhen the centroidal axes of axially loaded members meeting at a joint do not intersect at a common point, the effect of joint eccentricity shall be considered.

501(Replaces p. 501, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 27: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.18.1.3 Proportioning of splices and connectionsSplices and connections shall be designed for all of the forces, including axial, bending, and shear forces, that can occur in the connected components (allowing for any eccentricity of loading). Where the fatigue requirements of Clause 10.17 govern the design, the connections shall be designed to the same requirements.

10.18.1.4 Compression members finished to bearAt the ends of compression members that are finished to bear, splice material and connecting bolts or welds shall be arranged to hold all of the components in place and shall be proportioned to resist not less than 50% of the force effects at the ULS.

10.18.1.5 Beam and girder connectionsEnd connections for beams and girders that are proportioned to resist vertical reactions only shall be detailed to minimize the flexural end restraint, except that inelastic action in the connection at the SLS shall be permitted in order to accommodate the end rotations of unrestrained simple beams.

The connections of beams and girders subject to both reaction shear and end moment due to rigid, continuous, or cantilever construction shall be proportioned for the loads at the ULS. Axial forces, if present, shall also be considered.

Coping of flanges at connections may be used for secondary members in bridges with straight girders. Coping of flanges at connections of floor beams and main girders shall not be permitted. Blocks shall be used instead of copes whenever possible.

10.18.2 Bolted connections

10.18.2.1 GeneralAll high-strength bolts shall be pretensioned in accordance with Clause 10.24.6.3.

10.18.2.2 Bolts in tension

10.18.2.2.1 Tensile resistance at the ultimate limit statesThe factored tensile resistance, Tr , developed by the bolts in a bolted joint subject to tension, Tf , shall be taken as

Tr = 0.75b n Ab Fu

where

Fu = specified ultimate tensile strength of the bolt material

Bolts in tension shall be proportioned to resist the factored tensile force, Tf , taken as the sum of the factored external load and any additional tension resulting from prying action produced by the deformations of the connected parts, but neglecting bolt pretension.

10.18.2.2.2 Tensile resistance at the fatigue limit stateHigh-strength bolts subjected to tensile cyclic loading shall meet the requirements of Clause 10.17.2.6.

10.18.2.3 Bolted joints in shear

10.18.2.3.1 GeneralBolted joints required to resist shear between the connected parts shall be designed as slip-critical connections at FLS and SLS, except for connections of bracing members in straight girder bridges and connections not subjected to stress reversal.

(Replaces p. 502, November 2006)502

Single user license only. S

torage, distribution or use on network prohibited

Page 28: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.18.2.3.2 Slip resistance at the service load levelsThe slip resistance, Vs , of a bolted joint in a slip-critical connection subjected to shear, V, shall be taken as

Vs = 0.53c1ks mnAb Fu

where

ks = mean slip coefficient determined in accordance with Table 10.9 or by Approved tests

c1 = coefficient that relates the specified initial tension and mean slip to a 5% probability of slip for bolts installed by turn-of-nut procedures, as specified in Table 10.9

For installation using other procedures, different values of c1 apply. In long-slotted holes, the shear resistance shall be taken as 0.75Vs .

A slip-critical connection shall also satisfy the shear and bearing criteria at the ULS.

Table 10.9Values of ks and c1

(See Clauses 10.18.2.3.2 and 10.24.6.2.)

10.18.2.3.3 Shear resistance at the ultimate limit statesThe factored shear resistance of a bolted joint subject to a shear force, Vf , shall be taken as the lesser of(a) the bearing resistance, Br , of the plate adjacent to the bolts, as follows:

Br = 3br ntdFu

whereFu = ultimate strength of the platebr = 0.80

(b) the shear resistance, Vr , of the bolts, as follows:

Vr = 0.60b nmAb Fu

where

Fu = ultimate strength of the bolt material

For axially loaded lap splices with shear transfer length > 760 mm:

Vr = 0.50b nmAb Fu

If any bolt threads are intercepted by a shear plane, the factored shear resistance of the joint shall be taken as 0.7Vr .

Contact surface of bolted parts

ks

c1 (ASTM A 325 and ASTM F 1852)

c1 (ASTM A 490 and ASTM F 2280)Class Description

A Clean mill-scale or blast cleaned with Class A coatings 0.33 0.82 0.78

B Blast-cleaned surfaces or blast-cleaned surface with Class B coatings

0.50 0.90 0.85

C Hot-dip galvanized with hand wire-brushed surfaces 0.40 0.90 0.85

Note: Class A and B coatings are those coatings that provide a mean slip-coefficient of not less than 0.33 and 0.50, respectively. Values of c1 for a 5% probability of slip for values of ks other than those specified in this Table shall be determined by an Approved means.

503(Replaces p. 503, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 29: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.18.2.4 Bolts in shear and tension

10.18.2.4.1 Resistance at the serviceability limit statesBolts in a connection subjected to loads that cause shear, V, and tension, T, shall satisfy the following relationship:

The requirements of Clause 10.18.2.3.2 shall also be met.

10.18.2.4.2 Resistance at the ultimate limit statesA bolt that is required to resist a tensile force and a shear force at the ULS shall satisfy the following relationship:

10.18.3 Welds

10.18.3.1 GeneralWelding design shall comply with CSA W59, except as otherwise specified in Clause 10.18.3. The matching electrode classifications for CSA G40.21 and CSA W59 steels shall be as specified in Table 10.10.

Table 10.10Matching electrode classifications for

CSA G40.21 and CSA W59 steels(See Clause 10.18.3.1.)

10.18.3.2 Shear

10.18.3.2.1 Complete and partial joint penetration groove weldsThe factored shear resistance,Vr , shall be taken as the lesser of(a) for base metal:

Vr = 0.67w Am Fu

Matching electrode*

CSA G40.21 grade

260 300 350 380 400 480 700

430490550620820

XX

X†X X‡ X

X‡X

X

*The number indicates the tensile strength of the weld metal in megapascals, as indicated in the electrode classification number.†For hollow structural steel sections only.‡For uncoated applications using “A” or “AT” steels, where the deposited weld metal is to have atmospheric corrosion resistance and/or corrosion characteristics similar to those of the base metal, the requirements of Clauses 5.2.1.4 and 5.2.1.5 of CSA W59 shall apply.

VV

TnA Fs b u

+ ≤1 91 0

..

VV

TT

f

r

f

r

⎣⎢

⎦⎥ +

⎣⎢

⎦⎥ ≤

2 2

1 0.

(Replaces p. 504, November 2006)504

Single user license only. S

torage, distribution or use on network prohibited

Page 30: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

(b) for weld metal:

Vr = 0.67w Aw Xu

10.18.3.2.2 Fillet weldsThe factored resistance for tension- or compression-induced shear, Vr , shall be taken as the lesser of(a) for base metal:

Vr = 0.67 w Am Fu

(b) for weld metal:

Vr = 0.67 w Aw Xu (1.00 + 0.50 sin1.5) Rw

where

= angle between the axis of the weld segment and the line of action of the applied force (e.g., 0° for a longitudinal weld and 90° for a transverse weld)

Rw = strength reduction factor.

= 1.0 for the weld segment with the largest = 0.85 for the other weld segments

Note: It is a conservative simplification to take the bracketed quantity in Item (b) equal to 1.0.

10.18.3.3 Tension normal to the weld axisComplete joint penetration groove welds shall be made with matching electrodes. The factored tensile resistance shall be taken as that of the base metal.

10.18.3.4 Compression normal to the weld axisComplete and partial joint penetration groove welds shall be made with matching electrodes.

The factored compressive resistance shall be taken as that of the effective area of the base metal in the joint. For partial penetration groove welds, the effective area in compression shall be taken as the nominal area of the fusion face normal to the compression plus the area of the base metal fitted to bear.

10.18.3.5 Hollow structural sectionsThe provisions of Appendix L of CSA W59 should be applied to hollow structural sections.Note: Use of these provisions is strongly recommended.

10.18.4 Detailing of bolted connections

10.18.4.1 Contact of bolted partsBolted parts shall fit together solidly when assembled and shall not be separated by gaskets or any other interposed compressible material.

10.18.4.2 Hole sizeThe nominal diameter of a hole shall not be more than 2 mm greater than the nominal bolt size, except that where shown on the Plans, oversize or slotted holes may be used with high-strength ASTM A 325 or ASTM A 490 bolts 5/8 in or larger in diameter, or with ASTM A 325M or ASTM A 490M bolts 16 mm or larger in diameter.

Joints with oversize or slotted holes shall meet the following requirements:(a) Oversize holes shall not be more than 4 mm larger than bolts 22 mm or less in diameter, not more

than 6 mm larger than bolts 24 mm in diameter, and not more than 8 mm larger than bolts 27 mm or more in diameter. Oversize holes used in any plies of connections shall be provided with hardened washers under heads or nuts adjacent to plies containing oversize holes.

505(Replaces p. 505, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 31: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

(b) Short slotted holes shall not be more than 2 mm wider than the bolt diameter and shall not have a length that exceeds the oversize diameter requirements of Item (a) by more than 2 mm. When used in any plies of connections, hardened washers shall be provided under heads or nuts adjacent to plies containing slotted holes.

(c) Long slotted holes shall not be more than 2 mm wider than the bolt diameter and shall not be greater than 2.5 times the bolt diameter. They shall also comply with the following requirements:(i) when the slotted hole is normal to the direction of the load, the shear resistance shall be as

specified in Clause 10.18.2.3.2;(ii) they shall be used in only one of the connected parts at a given faying surface; and(iii) structural plate washers or a continuous bar not less than 8 mm thick shall cover long slots that

are in the outer plies of joints after installation.(d) When ASTM A 490 or ASTM A 490M bolts larger than 26 mm in diameter are used in oversize or

slotted holes in outer plies, the hardened washers shall be at least 8 mm thick and comply with ASTM F 436.

(e) The requirements for the nominal diameter of a hole shall not preclude the use of the following bolt diameters and hole combinations:(i) a 3/4 in bolt or an M20 bolt in a 22 mm diameter hole;(ii) a 7/8 in bolt or an M22 bolt in a 24 mm diameter hole; and(iii) a 1 in bolt or an M24 bolt in a 27 mm diameter hole.

10.18.4.3 CoatingsThe faying surfaces of slip-critical connections shall be shown on the Plans as coated or uncoated.

Where faying surfaces are to be coated, one of the following processes shall be used:(a) hot-dip galvanizing, provided that the faying surfaces are hand wire-brushed after galvanizing and

before assembly; (b) sprayed-zinc coatings, applied in accordance with CSA G189; or(c) other Approved materials and methods, provided that these have been tested in accordance with the

Specification for Structural Joints Using ASTM A325 or A490 Bolts issued by the Research Council on Structural Connections.

10.18.4.4 Bolt spacingThe minimum distance between centres of bolt holes shall not be less than 3 bolt diameters wherever practicable and never less than 2.7 diameters. The maximum bolt spacing shall be governed by the requirements for sealing or stitching specified in Clauses 10.18.4.5 to 10.18.4.7.

10.18.4.5 Sealing boltsFor sealing bolts, the pitch, p, between bolts on a single line adjacent to a free edge of an outside plate or shape shall be equal to or less than

(100 + 4t) 180

When a second line of fasteners is uniformly staggered with those in the line adjacent to the free edge, at a gauge less than 40 + 4t therefrom, the staggered pitch, p, in two such lines considered together shall be equal to or less than

or one-half the requirement for a single line, whichever is greater.

100 43

180+ − ⎡⎣⎢

⎤⎦⎥

≤tg

d

(Replaces p. 506, November 2006)506

Single user license only. S

torage, distribution or use on network prohibited

Page 32: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.18.4.6 Stitch boltsUnless closer spacing is required for transfer of load or for sealing inaccessible surfaces, the longitudinal spacing in-line between intermediate bolts in built-up compression members shall not exceed 12t. The gauge, g, between adjacent lines of bolts shall not exceed 24t. The staggered pitch between two adjacent lines of staggered holes shall not exceed

The pitch for tension members shall not exceed twice that specified for compression members. The gauge for tension members shall not exceed 24t.

p tg

t≤ − ⎡⎣⎢

⎤⎦⎥

≤1538

12

506A

Single user license only. S

torage, distribution or use on network prohibited

Page 33: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Single user license only. S

torage, distribution or use on network prohibited

Page 34: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.18.5.3.5 Stiffener connection and stiffener lengthStiffeners shall be connected so that the force in the stiffener is transferred through the stiffener connection. When beams frame to one side of a column only, the stiffeners need not be longer than one-half the depth of the column.

10.19 Anchor rods

10.19.1 GeneralAnchors provided to connect the superstructure to the substructure shall be proportioned to withstand the effect of uplift forces, bending moments, and shear at the ULS determined in accordance with Sections 3 and 5.

Anchor rods for bearing assemblies shall have a minimum diameter of 30 mm and a minimum embedment length of 300 mm.

The compression resistance of the concrete, the anchorage of rods, the shear resistance between the baseplate and substructure, and the moment resistance of anchorage systems shall be determined in accordance with Clause 8.16.7.

10.19.2 Anchor rod resistance

10.19.2.1 TensionThe factored tensile resistance, Tr , of an anchor rod shall be taken as

Tr = b As Fu

where

As = tensile stress area

=

where

p = pitch of threads, mm

10.19.2.2 ShearThe factored shear resistance, Vr , of an anchor rod shall be taken as

Vr = 0.60b n Ab Fu

but not be greater than the lateral bearing resistance specified in Clause 8.16.7.3. When rod threads are intercepted by the shear plane, the factored resistance shall be taken as 0.70Vr .

10.19.2.3 Combined tension and shearAn anchor rod required to develop resistance to both tension and shear shall be proportioned so that

VV

TT

f

r

f

r

⎣⎢

⎦⎥ +

⎣⎢

⎦⎥ ≤

2 2

1 0.

where

Vr = portion of the total shear per rod transmitted by bearing of the anchor rods on the concrete, as required by Section 8

π4

d p−( )0 938 2.

509(Replaces p. 509, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 35: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.19.2.4 Combined tension and bendingAnchor rods required to develop resistance to both tension and bending shall be proportioned to meet the requirements of Clause 10.8.3. The tensile and moment resistances, Tr and Mr , respectively, shall be based on the properties of the cross-section at the critical section; Mr shall be taken as bSFy .

10.20 Pins, rollers, and rockers

10.20.1 Bearing resistanceThe factored bearing resistance, Br , developed by a component or portion of a component subjected to bearing shall be calculated as follows:(a) on the contact area of machined, accurately sawn, or fitted parts and on the bearing area of pins:

Br = 1.50 s Fy A

where the bearing area of pins is taken as the pin diameter multiplied by the thickness of the connected parts; and

(b) on expansion rollers or rockers:

where

Fy = specified minimum yield point of the weaker part in contact

10.20.2 Pins

10.20.2.1 Bending resistanceThe factored bending resistance of a pin shall be taken as Mr = sSFy .

10.20.2.2 Shear resistanceThe factored shear resistance of a pin shall be taken as Vr = 0.60 s AFy .

10.20.2.3 Combined bending and shearSections of pins subject to both bending and shear shall be proportioned so that

MM

VV

f

r

f

r+

⎣⎢

⎦⎥ ≤3

1 0.

10.20.2.4 Pin connection detailsPins shall be of sufficient length to ensure full bearing of all parts connected to the turned body of the pin. They shall be secured in position by hexagonal recessed nuts or by hexagonal solid nuts with washers or, if the pins are bored, by throughrods with recessed cap washers. Pin nuts shall be malleable steel castings or steel and shall be secured by cotter pins in the screw ends or with locknuts.

Pins shall be located so as to minimize the force effects due to eccentricity. Pin plates shall contain sufficient welds or fasteners to distribute their portion of the pin load to the full cross-section of the component with due consideration given to the effects of eccentricity.

BR

RR

LFr s y=−

⎢⎢⎢

⎥⎥⎥

0 000261

1

1

2

2. f

(Replaces p. 510, November 2006)510

Single user license only. S

torage, distribution or use on network prohibited

Page 36: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.21 Torsion

10.21.1 GeneralMembers and their connections subjected to torsion shall have sufficient strength and rigidity to resist the torsional moments and forces in addition to other moments and forces. The torsional deformations at the SLS shall be within acceptable limits.

10.21.2 Members of closed cross-section

10.21.2.1 Torsional resistanceThe factored torsional resistance, Qr , taking the warping constant, Cw , to be zero, shall be calculated as

Q F A tr s y= ′2

3f

where

t = minimum thickness of material, provided that the width-to-thickness ratios of elements are

(a) for flat plate elements:

b/t 1100/

(b) for circular hollow sections (or multi-sided hollow sections that approximate a circle):

D / t 18 000/ Fy

When a width-to-thickness ratio exceeds a ratio specified in Item (a) or (b), as applicable, the torsional resistance shall be calculated using an elastic analysis.

10.21.2.2 Combined axial compression, flexure, and torsionMembers of closed cross-section subject to combined axial compression, flexure, and torsion shall be proportioned so that

where Cr is as specified in Clause 10.9.3, Mr is as specified in Clause 10.10, and Qr is as specified in Clause 10.21.2.1.

10.21.2.3 Reinforcement of cut-outsMembers with cut-outs whose torsional design is based on the cross-sectional properties of the closed cross-section shall be detailed as follows:(a) cut-outs shall have semicircular ends;(b) the width of a cut-out shall not exceed 0.17 times the circumference of the member;(c) a stiffener shall be provided around the perimeter of the cutout and welded to develop the full

cross-section of the wall. The stiffener shall have a cross-sectional area, A, of

where

L = length of the cut-out measured parallel to the longitudinal axis of the member

t = thickness of the wall of the member

(d) the width-to-thickness ratio of the outstanding portions of the stiffener shall not exceed 170/ .

Fy

CC

M

MCC

QQ

f

r

f

rf

e

f

r+

−⎡

⎣⎢

⎦⎥

+⎡

⎣⎢

⎦⎥ ≤

1

1 02

.

A L t= ( )/ 3

Fy

511(Replaces p. 511, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 37: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.21.3 Members of open cross-section

10.21.3.1 St. Venant torsional constantThe St. Venant torsional constant shall be calculated as

Jbt= S

3

3

where

b = length of the plate element

t = thickness of the plate element

The width-to-thickness ratios of elements shall meet the requirements of Clause 10.9.2.

10.21.3.2 Warping constantThe warping constant, Cw , shall be calculated as follows: (a) for a doubly symmetric I-shaped section:

(b) for a monosymmetric I-shaped section:

where

Iy = moment of inertia about the minor axis

Iy1 , Iy2 = moment of inertia of the upper and lower flanges, respectively, about the y-axis of symmetry

(c) for a closed rectangular section:

where

If =

Iw =

10.21.3.3 Torsional resistanceThe factored torsional resistance of members of open cross-section shall be calculated based on accepted principles of elastic torsional analysis, taking into account the St. Venant and warping torsional resistance as a function of the loading and restraint conditions.

10.21.3.4 Combined bending and torsionFor I-shaped members subject to torsion or combined bending and torsion, the maximum combined normal stress due to warping torsion and bending at SLS loads, as determined by an elastic analysis, shall not exceed Fy .

Cl h

wy=

2

4

Ch l l

l lw

y y

y y

=+( )

21 2

1 2

C ld

Ib

w f w= ⎡⎣⎢

⎤⎦⎥

+ ⎡⎣⎢

⎤⎦⎥

22

22

2 2

b t3

12

d w3

12

(Replaces p. 512, November 2006)512

Single user license only. S

torage, distribution or use on network prohibited

Page 38: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.22 Steel piles

10.22.1 GeneralThe structural design of steel piles shall be in accordance with this Section. The geotechnical design shall be in accordance with Section 6.

10.22.2 Resistance factorsThe resistance factor to be used when calculating the factored axial compressive resistance for piles under axial compression alone in accordance with Clause 10.22.3.1 shall be 0.70. The factor given in Clause 6.8.8.5 shall also apply unless the pile is not driven into the soil but rather lowered into a pre-augered hole.

When calculating the resistance of the pile above the point of fixity, the resistance factors for coincident axial compression and bending shall be 0.70 for compression and 0.95 for flexure.

10.22.3 Compressive resistance

10.22.3.1 Axial compressionFor piles under axial compression alone, the factored axial compressive loads shall not exceed the factored compressive resistance specified in Clause 10.9.3.

10.22.3.2 Combined axial compression and bendingPiles under coincident axial compression and bending shall satisfy the following:(a) The factored axial compressive loads shall not exceed the axial compressive resistance of the pile, as

calculated under Clause 10.22.3.1.(b) The coincident axial compressive and flexural loads and resistance of the pile above the point of fixity

shall satisfy the requirements of Clause 10.9.4.

10.22.4 Unsupported lengthFor piles that are subjected to axial compression alone and are fully embedded in soil, the unsupported length, L, shall be taken as zero.

If the pile extends above the ground surface in air or water, or is subjected to combined axial compression and bending, the unsupported length of the pile shall include the length of the pile above the soil, if any, plus an embedded depth to fixity.

10.22.5 Effective length factorThe effective length factor, K, shall be determined on the basis of the restraint provided by the soil, the pile cap, the structure, and the substructure, as specified in Section 6.

10.22.6 SplicesSplices shall be proportioned to develop the full cross-sectional strength of the pile.

10.22.7 WeldingWelding shall be in accordance with Clause 10.24.5.

10.22.8 Composite tube pilesFor composite tube piles, the applicable requirements of Clause 10.9.5 shall be met.

513(Replaces p. 513, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 39: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.23 Fracture control

10.23.1 GeneralFracture control shall be considered throughout material selection and structural design. Consideration shall be given to(a) designation of fracture-critical and primary tension members;(b) the level of quality control, inspection, and monitoring during fabrication;(c) the likelihood of crack initiation and crack growth;(d) selection of steel and welding consumables with appropriate toughness; and(e) controlling stress concentrations and improper alignment.

10.23.2 IdentificationThe components identified as fracture-critical members and primary tension members shall be clearly identified in the Plans. Shop drawings shall identify the extent of fracture-critical and primary tension members. Attachments longer than 100 mm in the direction of tension and welded to the tension zone of a fracture-critical or primary tension member shall be treated as part of that member.

For each component of a fracture-critical or primary tension member, records shall be kept to identify the heat number of the material and its corresponding mill test certificate.

The fracture-toughness and welding requirements of Clauses 10.23.3 to 10.23.5 shall apply only to members designated as fracture-critical and primary tension members.

10.23.3 Fracture toughness

10.23.3.1 GeneralThe Charpy V-notch requirements specified in Clause 10.23.3 shall apply only to standard full-size specimens. For plates from 8 to 11 mm thick, subsize specimens with adjusted energy levels may be used, as permitted by CSA G40.20. The requirements of Clause 10.23.3 shall apply to both bolted and welded construction.

10.23.3.2 Fracture-critical membersFor fracture-critical members, Charpy V-notch tests shall be specified on a per plate frequency, as defined in CSA G40.20/G40.21. The steel shall meet the impact energy requirements specified in Table 10.12.

10.23.3.3 Primary tension membersFor primary tension members, Charpy V-notch tests shall be specified on a per heat frequency, as defined in CSA G40.20/G40.21. The steel shall meet the impact energy requirements specified in Table 10.13.

10.23.3.4 Service temperatureThe applicable minimum service temperature, Ts , shall be the minimum daily mean temperature in Figure A3.1.2.

10.23.3.5 Weld metal toughnessFor fracture-critical and primary tension members, the weld metal shall meet the impact energy requirements of (a) Clause 10.23.4; and (b) Tables 10.14A and 10.14B, respectively.

10.23.3.6 Steel for permanent backing barsSteel for permanent backing bars shall meet the requirements of Clause 5.5.1.1 of CSA W59 and shall meet the Charpy impact energy requirements of Table 10.12 or 10.13, as applicable.

(Replaces p. 514, November 2006)514

Single user license only. S

torage, distribution or use on network prohibited

Page 40: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Table 10.12Impact test temperatures and Charpy impact energy requirements

for fracture-critical members(See Clauses 10.23.3.2, 10.23.3.6, and 10.23.4.4.)

Table 10.13Impact test temperatures and Charpy impact energy requirements

for primary tension members(See Clauses 10.23.3.3, 10.23.3.6, and 10.23.4.4.)

CSA G40.21grade

Minimum averageenergy, J

Test temperature, Tt , °C, for minimum service temperature, Ts, °C

Ts –30 –30 > Ts – 60 Ts < – 60

Commonly used steels

260 WT300 WT350 WT and AT400 WT and AT

20202727

–10–10–10–10

–30–30–30–30

–50–50–50–50

Steels requiring Approval

480 WT and AT700 QT

4050

–10–20

– 40– 40

– 60– 60

CSA G40.21grade

Minimum averageenergy, J

Test temperature, Tt , °C,for minimum service temperature, Ts, °C

Ts –30 –30 > Ts – 60 Ts < – 60

Commonly used steels

260 WT300 WT350 WT and AT400 WT and AT

20202727

0000

–20–20–20–20

–30–30–30–30

Steels requiring Approval

480 WT and AT700 QT

2734

–10–20

–30– 40

– 40–50

514A

Single user license only. S

torage, distribution or use on network prohibited

Page 41: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Single user license only. S

torage, distribution or use on network prohibited

Page 42: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Table 10.14AImpact test temperatures and Charpy impact energy requirements

for weld metal in fracture-critical members(See Clauses 10.23.3.5 and 10.23.4.2–10.23.4.5.)

Table 10.14BImpact test temperatures and Charpy impact energy requirements

for weld metal in primary tension members(See Clauses 10.23.3.5 and 10.23.4.2–10.23.4.5.)

10.23.4 Welding of fracture-critical and primary tension members

10.23.4.1 GeneralThe requirements of Clauses 10.23.4.2 to 10.23.4.6 and 10.24 shall apply to the welding of fracture-critical and primary tension members.

10.23.4.2 Welding consumablesExcept as permitted by Clause 10.23.4.5, only welding consumables with Charpy V-notch toughness requirements in compliance with Tables 10.14A and 10.14B, as applicable, and certified by the Canadian Welding Bureau to CAN/CSA-W48 shall be used. In the absence of an applicable CAN/CSA-W48 requirement, the applicable Standard(s) in the American Welding Society A5 series of Standards shall be used.

In groove welds connecting two different grades of steel, the classification of consumables used, including Charpy V-notch impact requirements, shall be that applicable to the grade with the lower ultimate tensile strength.

Base metalCSA G40.21grade

Minimum averageenergy, J

Test temperature, Tt , °C,for minimum service temperature, Ts, °C

Ts – 40 – 40 > Ts – 60 Ts < – 60

260 WT300 WT350 WT and AT400 WT and AT480 WT and AT700 QT

2020272727—

–30–30–30–30– 40*

– 40– 40– 40– 40– 60*

–60– 60– 60– 60**

*Welded construction using 480WT and 700QT steels shall require Approval and special considerations. Joining by bolting is recommended for these applications.

Base metalCSA G40.21 grade

Minimum average energy, J

Test temperature, Tt , °C,for minimum service temperature, Ts, °C

Ts – 40 Ts < – 40

260 WT300 WT350 WT and AT400 WT and AT480 WT and AT700 QT

202027272740

–30–30–30–30– 35–45

–40– 40– 40– 40– 45– 45

515(Replaces p. 515, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 43: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.23.4.3 Approval and verification of consumablesFor groove welds in fracture-critical and primary tension members using certified consumables where the Charpy V-notch test temperature required by Tables 10.14A and 10.14B is lower than the test temperature required by CAN/CSA-W48 or the applicable Standard(s) in the American Welding Society A5 series of Standards, or where these Standards are not applicable, welding consumables shall be Approved by the Canadian Welding Bureau and qualified using a verification test assembly to establish the impact properties of the weld metal. The test procedures shall be those specified in CAN/CSA-W48 or the applicable American Welding Society Standard, except that only Charpy V-notch tests shall be required and welding shall be carried out using the preheat and the maximum heat input to be used in practice. The Charpy V-notch results shall meet the requirements of Table 10.14A or 10.14B, as applicable. Qualification shall be required for each electrode diameter used and for the consumables supplied by each manufacturer. The qualification shall be valid for consumables for all groove weld procedures that use a heat input the same as or lower than that used in the qualification test.

10.23.4.4 Welding 700Q and 700QT steelsFor groove weld procedures involving fracture-critical and primary tension members made of 700Q and 700QT steels, consumables shall be qualified by welding procedure tests and Approved by the Canadian Welding Bureau. The tests shall be conducted in accordance with CSA W47.1 using 700Q or 700QT steels for the base plate and shall include weld metal and heat-affected zone (HAZ) Charpy V-notch impact tests in accordance with Appendix E of CSA W47.1. Weld metal impact tests shall meet the requirements of Table 10.14A or 10.14B, as applicable, and HAZ impact tests shall meet the requirements of Tables 10.12 or 10.13 for the base plate, as applicable. Only manufacturers of qualified consumables shall supply consumables for fabrication. The qualification shall be valid for all groove weld procedures that use a heat input the same as or lower than that used in the qualification test.

10.23.4.5 Qualification of consumablesWhen the welding consumables have not previously been certified by the Canadian Welding Bureau, they shall be qualified by welding procedure tests in accordance with Clause 11.8.2.1(b) of CSA W47.1 and shall include Charpy V-notch impact tests of the weld metal. For steels other than 700Q and 700QT Charpy V-notch tests in the HAZ shall not be required. Weld metal Charpy V-notch properties shall be established by qualification tests in accordance with CSA W47.1 (including Appendix E) and shall meet the requirements of Tables 10.14A and 10.14B, as applicable. Only manufacturers of qualified consumables shall supply consumables for fabrication. Qualification testing shall be performed for each lot or batch of consumables. The qualification shall be valid for all weld procedures that use a heat input the same as or lower than that used in the qualification test. Consumables for 700Q and 700QT steels shall be qualified in accordance with Clause 10.23.4.4.

10.23.4.6 Tack welds and temporary weldsTack welds shall not be used on fracture-critical or primary tension members unless they are incorporated into the final weld. Temporary welds shall not be used on fracture-critical or primary tension members, or on flange material in compression, unless Approved.

10.23.5 Welding corrections and repairs to fracture-critical members

10.23.5.1 GeneralExcept as specified in Clause 10.23.5.4(c), repairs to base metal and to welded joints shall be documented. The documentation shall include all of the details specified in Clauses 10.23.5.6 and 10.23.5.7. Welding repair procedures shall be Approved by the Engineer in accordance with Clauses 10.23.5.4 and 10.23.5.5, as applicable.

10.23.5.2 Repair of base metalRepair of base metal by welding at the producing mill shall not be permitted.

(Replaces p. 516, November 2006)516

Single user license only. S

torage, distribution or use on network prohibited

Page 44: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Table 10.16Minimum elapsed time for acceptance testing

(See Clause 10.23.5.7.)

10.23.5.8 Compliance with Approved proceduresAll repair welding and non-destructive testing shall be performed as described in the Approved repair procedure.

10.23.5.9 RecordsApproved critical repair procedures shall be retained as part of the project records.

10.23.6 Non-destructive testing of fracture-critical membersThe use of Cobalt 60 as a radiographic source in quality control shall be permitted only when the steel being tested is more than 75 mm thick.

The Constructor shall maintain documentation of all visual and non-destructive testing for review and confirmation by the Engineer. The documentation shall be submitted to the Engineer on completion of the project.

10.24 Construction requirements for structural steel

10.24.1 GeneralClauses 10.24.2 to 10.24.10 specify requirements for the construction of structural steel for highway bridges and applies unless otherwise specified by the authority having jurisdiction. The requirements specified in these Clauses are provided to ensure compliance with the design philosophy of this Section.

10.24.2 Submissions

10.24.2.1 GeneralErection diagrams, shop details, welding procedures, and erection procedure drawings and calculations shall be submitted to the Owner. This requirement shall be stipulated on the Plans.

10.24.2.2 Erection diagramsErection diagrams are general-arrangement drawings showing or indicating the principal dimensions of the bridge, piece marks, the sizes of all members, field welding requirements, the sizes and types of bolts, and bolt installation requirements.

10.24.2.3 Shop detailsShop details shall provide(a) full detail dimensions and sizes of all component parts of the structure. These dimensions shall make

allowance for changes in shape due to weld shrinkage, camber, and any other effects that cause finished dimensions to differ from initial dimensions;

(b) all necessary specifications for the materials to be used;(c) identification of areas requiring special surface treatment;(d) identification of fracture-critical and primary tension members and component parts;

Plate thickness, t, mmMagnetic particlefor fillet welds

Ultrasonic examinationof groove welds

t 50t > 50

24 h24 h

24 h48 h

519(Replaces p. 519, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 45: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

(e) bolt installation requirements; and(f) details of all welds.

10.24.2.4 Welding proceduresWelding procedures shall comply with CSA W47.1.

10.24.2.5 Erection procedure drawings and calculationsThe erection procedure drawings and calculations shall fully indicate the proposed method of erection, including the sequence of erection, the weights and lifting points of the members, and the location and lifting capacities of the cranes used to lift them. Details of temporary bracing and bents to be used during construction shall be shown. Calculations shall be provided to show that members and supports are not overloaded during erection.

10.24.2.6 Symbols for welding and non-destructive testingThe symbols for welding and non-destructive testing on shop drawings shall be in accordance with CSA W59.

10.24.3 Materials

10.24.3.1 SteelSubstitution of steel members or components for size and grade shall not be permitted unless Approved. All steel shall be new. Acceptance of any material by an inspector shall not preclude subsequent rejection of the material if it is found defective.

10.24.3.2 High-strength bolts, nuts, and washersNuts and bolts shall be shipped together as an assembly.

The nuts of galvanized fasteners shall be overtapped by the minimum amount required for assembly and shall be lubricated with a lubricant containing a visible dye. The use of a mechanically deposited zinc coating shall require Approval.

10.24.3.3 — Deleted

10.24.3.4 — Deleted

10.24.4 Fabrication

10.24.4.1 Quality of workThe standards for quality of work and finish shall comply with the best modern practices for steel bridge fabrication (with particular attention to the appearance of parts exposed to view).

10.24.4.2 Storage of materialsPlain or fabricated structural steel shall be stored above the ground on skids or other supports and kept free from dirt and other foreign matter. Long members shall be adequately supported to prevent excessive deflection.

10.24.4.3 Plates

10.24.4.3.1 Direction of rollingUnless otherwise shown on the Plans, steel plates for main members (and their splice plates) shall be cut so that the primary direction of rolling is parallel to the direction of tensile or compressive stress.

(Replaces p. 520, November 2006)520

Single user license only. S

torage, distribution or use on network prohibited

Page 46: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.24.4.3.2 Plate edgesSheared edges of plates more than 16 mm thick and carrying calculated tension shall be planed, milled, or ground a minimum of 3 mm.

Oxygen cutting of structural steel shall be done by machine, except that hand-guided cutting shall be allowed for copes, blocks, and similar cuts where machine cutting is impracticable. Re-entrant corners shall be free from notches and shall have a fillet of the largest practical radius, but not less than 25 mm.

The quality and repair of the cut edges shall comply with Clause 5 of CSA W59. All cut edges shall have a surface roughness not greater than 1000, as specified by CSA B95.

Corners of oxygen-cut girder flange tips shall be chamfered 2.0 mm by grinding.

10.24.4.3.3 Camber in web platesWebs shall be cut to the prescribed camber, with allowance for shrinkage due to cutting and subsequent welding. The requirements of Clauses 10.7.4.2 and 10.7.4.3 shall also apply.

10.24.4.3.4 Bent platesThe following requirements shall apply to bent plates:(a) Load-carrying, rolled steel plates to be bent shall

(i) be cut from the stock plates so that the bend line is at right angles to the direction of rolling, except as otherwise Approved for orthotropic decks; and

(ii) have their corners lightly chamfered by grinding in the region of the bend before bending.(b) Cold bending shall be carried out so that no cracking or tearing of the plate occurs. Minimum bend

radii, measured to the concave face of the metal, shall be as shown in Table 10.17.(c) Hot bending at a plate temperature not greater than 600 °C shall be used to form radii less than

those specified for cold bending. Accelerated cooling using compressed air or water shall be used for a hot bent component only when its temperature is below 300 °C.

Table 10.17Minimum bend radii for bent plates

(See Clause 10.24.4.3.4.)

10.24.4.4 Straightening materialAll steel shall be flat and straight before being worked. Steel with sharp kinks or bends may be rejected. Attempts to straighten sharp kinks or bends shall require Approval.

Rolled plates, sections, and built-up members may be straightened using mechanical means or by the application of a controlled heating procedure in accordance with Clause 5.10.5 of CSA W59. After straightening of a bend or buckle, the surface of the steel shall be examined for evidence of fracture or other damage and corrective action taken if necessary.

t, mmMinimum radius

12 or less 2t

Over 12 to 25 2.5t

Over 25 to 38 3t

Over 38 to 65 3.5t

Over 65 to 100 4t

521(Replaces p. 521, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 47: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.24.4.5 Bolt holes

10.24.4.5.1 GeneralAll holes shall be drilled or reamed to the finished diameter, except that punched holes shall be allowed in material up to 16 mm thick.

When shown on the Plans, oversize or slotted holes in accordance with Clause 10.18.4.2 are permitted.

10.24.4.5.2 Punched holesThe diameter of a punched hole shall be not more than 2 mm larger than the nominal diameter of the bolt unless oversize holes are specified.

The diameter of the die shall not exceed the diameter of the punch by more than 2 mm. Holes shall be clean cut and without ragged or torn edges, but the lightly conical hole that results from clean cutting shall be acceptable. Holes may be reamed to admit fasteners.

10.24.4.5.3 Reamed holesHoles that are to be reamed to final diameter shall first be subdrilled or subpunched to 4 mm smaller than the nominal diameter of the bolt. With the connecting parts assembled and securely held, the holes shall then be reamed to 2 mm larger than the nominal diameter of the bolts. The parts shall be match-marked before disassembly.

10.24.4.5.4 Drilled holesHoles that are drilled full-size shall be 2 mm larger than the nominal diameter of the bolt unless oversize holes have been specified. They shall be accurately located by using suitable numerically controlled drilling equipment, or by using a steel template carefully positioned and clamped to the steel. The accuracy of the holes prepared in this manner, and their locations, shall be such that like parts are identical and require no match-marking.

The holes for any connection may be drilled full-size when the connecting parts are assembled and clamped in position, in which case the parts shall be match-marked before disassembly.

10.24.4.6 Pins and rollersPins and rollers shall be accurately turned to the dimensions and finish shown on the drawings and shall be straight and free from flaws. Pins and rollers more than 175 mm in diameter shall be forged and annealed. Pins and rollers 175 mm or less in diameter may be either forged and annealed or of cold-finished carbon-steel shafting.

Holes for pins shall be bored to the specified diameter and finish at right angles to the axis of the member. The diameter of the pin hole shall not exceed that of the pin by more than 0.5 mm for pins 125 mm or less in diameter or more than 0.75 mm for larger pins. Pin holes shall be bored on completion of the assembly of built-up members.

10.24.4.7 Curved girders

10.24.4.7.1 GeneralFlanges of curved, welded I-girders may be cut to the radius. However, they may be curved by applying heat if the radius, R, is greater than 45 000 mm and also exceeds

where

Fy = specified minimum yield stress of the web

37 51700b h

F w

bF

f

y

f

yy y and

(Replaces p. 522, November 2006)522

Single user license only. S

torage, distribution or use on network prohibited

Page 48: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.24.4.7.2 Heat curving of rolled beams and welded girdersSteel beams and girders with a specified minimum yield point greater than 350 MPa shall not be heat curved. In heat curving using the continuous or V-type heating pattern, the temperature of the steel shall not exceed 600 °C, as measured by temperature-indicating crayons.

A detailed procedure for the heat-curving operation shall be submitted for review. The procedure shall describe the type of heating to be employed, the extent of the heating patterns, the sequence of operations, and the method of support of the girder, including an assessment of any dead-load stresses present during the operation.

Transverse web stiffeners may be welded in place either before or after the heat-curving operation. However, unless allowance is made for the longitudinal shrinkage, bracing connection plates and bearing stiffeners shall be located and welded after curving.

Girders shall be cambered before heat curving. Rolled sections may be heat cambered using an Approved procedure. Plate girders shall have the required camber cut into the web, with suitable allowance for camber loss due to cutting, welding, and heat curving.

10.24.4.8 Identification markingEach member shall carry an erection mark for identification. Low-stress stamps — stamps with blunt-nosed markings — may be used on low-stress areas of main members or on secondary members as a means of permanent identification.

10.24.5 Welded construction

10.24.5.1 GeneralAll welding procedures, including those related to quality of work, techniques, repairs, and qualifications, shall comply with CSA W47.1 and CSA W59, except where modified by Clauses 10.24.5.2 to 10.24.5.7.

10.24.5.2 Processes with limited applicationThe electroslag and electrogas welding processes specified in Clause 5 of CSA W59 shall not be used for welding quenched and tempered steels or for welding components of members subject to tension stress or stress reversal.

10.24.5.3 Primary tension and fracture-critical membersMembers and components of members designated primary-tension or fracture-critical shall meet the requirements of Clause 10.23 in addition to the requirements of CSA W59. The use of heat to alter the sweep or camber of fracture-critical girders shall require Approval.

10.24.5.4 SubmissionsCWB-accepted welding procedure specifications, data sheets, and repair procedures for prequalification shall be submitted to the Owner in compliance with the Plans.

10.24.5.5 Certification of welding operationsAny company undertaking welded fabrication and/or welded erection (including steel piles, railings and guards, or other welded attachments) shall be certified to Division 1 or 2 of CSA W47.1.

10.24.5.6 Complete joint penetration groove weldsComplete joint penetration groove welds shall conform to CSA W59, Clause 12.

Runoff tabs or extension bars shall be provided so that groove welds terminate on the tab and shall be removed upon completion of the joint. The welds that attach the tabs to the piece being welded shall be placed inside the joint so that they are incorporated into the final weld.

The conditions for the type, use, and removal of the welding backing bar, if used, shall comply with CSA W59, Clause 12, or as otherwise directed by the Engineer.

523(Replaces p. 523 November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 49: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.24.5.7 Web to flange fillet weldsWhere practicable, web to flange fillet welds shall be made continuously by machine or automatic welding. Welds may be repaired using either a semi-automatic or manual process, but the repaired weld shall blend smoothly with the adjacent welds.

10.24.6 Bolted construction

10.24.6.1 GeneralClauses 10.24.6.2 to 10.24.6.11 specify requirements for bolted steel construction using ASTM A 325/A 325M or ASTM A 490/A 490M high-strength bolts.

10.24.6.2 AssemblyWhen assembled, all joint surfaces, including those adjacent to bolt heads, nuts, and washers, shall be free from loose scale, burrs, dirt, and foreign material that would prevent the solid seating of the parts.

The faying surfaces of connections designed in accordance with Clause 10.18.2.3.2 shall be prepared as follows:(a) For clean mill scale, the surfaces shall be free from oil, paint, lacquer, or any other coating in all areas

within the bolt pattern and for a distance beyond the edge of the bolt hole that is the greater of 25 mm or the bolt diameter.

(b) For Classes A and B (see Table 10.9), the surfaces shall have the same blast cleaning and coating application as was used in the tests to determine the mean slip coefficient. Coated joints shall not be assembled before the coating has cured for the minimum time used in the tests to determine the mean slip coefficient.

(c) For Class C (see Table 10.9), the surfaces shall be hot-dip galvanized in accordance with CAN/CSA-G164 and subsequently roughened by hand wire-brushing. Power wire-brushing shall not be used.

10.24.6.3 Installation of boltsPretensioned bolts shall be tightened in accordance with Clause 10.24.6.6 to at least 70% of the minimum tensile strength specified in the applicable ASTM Standard.

10.24.6.4 Hardened washersThe following requirements shall apply to hardened washers:(a) Hardened washers shall be provided as follows under the element turned (head or nut) during

installation:(i) as required by Clause 10.24.6.7; and(ii) for ASTM A 490/A 490M bolts.

(b) Hardened washers shall also be required(i) for oversize or slotted holes that meet the requirements of Clause 10.18.4.2;(ii) under the head and nut of ASTM A 490/A 490M bolts when used with steel with a specified

minimum yield strength of less than 280 MPa; and(iii) when ASTM A 490/A 490M bolts of greater than 26 mm diameter are used in oversize or slotted

holes. The washers in this case shall have a minimum thickness of 8 mm.

(Replaces p. 524, November 2006)524

Single user license only. S

torage, distribution or use on network prohibited

Page 50: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.24.6.5 Bevelled washersBevelled washers shall be used to compensate for lack of parallelism where, in the case of ASTM A 325/A 325M bolts, an outer face of bolted parts has more than a 5% slope with respect to a plane normal to the bolt axis. In the case of ASTM A 490/A 490M bolts, bevelled washers shall be used to compensate for any lack of parallelism due to the slope of outer faces.

10.24.6.6 Turn-of-nut tighteningAfter the holes in a joint are aligned, a sufficient number of bolts shall be placed and brought to a snug-tight condition to ensure that the parts of the joint are brought into full contact with each other.

Following the initial snugging operation, bolts shall be placed in any remaining open holes and brought to snug-tightness. Resnugging can be necessary in large joints.

When all bolts are snug-tight, each bolt in the joint shall be further tightened by the applicable amount of relative rotation specified in Table 10.18, with tightening progressing systematically from the most rigid part of the joint to its free edges. During this operation, there shall be no rotation of the part not turned by the wrench unless the bolt and nut are match-marked to enable the amount of relative rotation to be determined.

Table 10.18Nut rotation from snug-tight condition*

(See Clauses 10.24.6.6 and 10.24.6.7.)

10.24.6.7 InspectionAn inspector shall determine whether the requirements of Clauses 10.24.3.2 and 10.24.6.2 to 10.24.6.6 have been met. Installation of bolts shall be observed to ascertain that a proper tightening procedure is employed. The turned element of all bolts shall be visually examined for evidence that they have been tightened.

When properly installed, the tip of the bolt shall be flush with or outside the face of the nut.Tensions in bolts installed by the turn-of-nut method exceeding those specified in Clause 10.24.6.3 shall

not be cause for rejection.When there is disagreement concerning the results of an inspection of bolt tension, the following

arbitration procedure shall be used unless a different procedure has been specified:(a) The inspector shall use an inspection wrench that is a manual or power torque wrench capable of

indicating a selected torque value.(b) Three bolts of the same grade and diameter as those under inspection and representative of the

lengths and conditions of those in the bridge shall be placed individually in a calibration device capable of measuring bolt tension. There shall be a washer under the part turned if washers are so used in the bridge or, if no washer is used, the material abutting the part turned shall be of the same specification as that in the bridge.

Disposition of outer faces of bolted parts Bolt length† Turn from snug

Both faces normal to the bolt axis or one face normal to the axis and the other sloped 1:20 (bevelled washers not used)‡

Up to and including four diameters 1/3

Over four diameters and not exceeding eight diameters or 200 mm

1/2

Exceeding eight diameters or 200 mm 2/3

Both faces sloped 1:20 from normal to the bolt axis (bevelled washers not used)‡

All lengths 3/4

*Nut rotation is rotation relative to a bolt regardless of whether the nut or bolt is turned. The tolerance on rotation is 30° over. This Table applies to coarse-thread, heavy-hex structural bolts of all sizes and lengths used with heavy-hex semi-finished nuts.†Bolt length is measured from the underside of the head to the extreme end point.‡Bevelled washers are necessary when ASTM A 490/A 490M bolts are used.

525(Replaces p. 525, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 51: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

(c) When the inspection wrench is a manual wrench, each bolt specified in Item (b) shall be tightened in the calibration device by any convenient means to an initial tension of approximately 15% of the required fastener tension, and then to the minimum tension specified for its size in Clause 10.24.6.3. Tightening beyond the initial condition shall not produce greater nut rotation beyond that permitted by Table 10.18. The inspection wrench shall then be applied to the tightened bolt and the average torque necessary to turn the nut or head 5° in the tightening direction shall be determined. The average torque measured in these tests of three bolts shall be taken as the job inspection torque to be used in the manner specified in Item (e). The job inspection torque shall be established at least once each working day.

(d) When the inspection wrench is a power wrench, it shall first be applied to produce an initial tension of approximately 15% of the required fastener tension and then adjusted so that it will tighten each bolt specified in Item (b) to a tension of at least 5% but not more than 10% greater than the minimum bolt tension specified for its size in Clause 10.24.6.3. This setting of the wrench shall be taken as the job inspection torque to be used in the manner specified in Item (e). Tightening beyond the initial condition shall not produce greater nut rotation than that permitted by Table 10.18. The job inspection torque shall be established at least once each working day.

(e) Bolts represented by the sample specified in Item (b) that have been tightened in the bridge shall be inspected by applying, in the tightening direction, the inspection wrench and its job inspection torque to 10% of the bolts (but not fewer than two bolts) selected at random in each connection. If no nut or bolt head is turned by this application of the job inspection torque, the connection shall be accepted as being properly tightened. If any nut or bolt head is turned by the application of the job inspection torque, this torque shall be applied to all of the bolts in the connection, and all of the bolts whose nut or head is turned by the job inspection torque shall be retightened and reinspected. Alternatively, the fabricator or erector, at his or her option, may retighten all of the bolts in the connection and then resubmit the connection for inspection.

10.24.6.8 Reuse of boltsASTM A 490/A 490M and galvanized ASTM A 325/A 325M bolts shall not be reused once they have been fully tightened. Other ASTM A 325/A 325M bolts may be reused up to two times, provided that proper control on the number of reuses can be established. Touch-up of pretensioned bolts in a multi-bolt joint shall not constitute a reuse unless a bolt becomes substantially unloaded as other parts of the joint are bolted.

10.24.6.9 Shop trial assemblyGirders and other main components shall be preassembled in the shop in order to prepare or verify the field-splices. Components shall be supported in a manner consistent with the finished geometry of the bridge, as specified on the Plans, with allowance for any camber required to offset the effects of dead load deflection.

Holes in the webs and flanges of main components shall be reamed or drilled to final size while in assembly. The components shall be pinned and firmly drawn together by bolts before reaming or drilling. Drifting done during assembly shall be sufficient only to align the holes and not to distort the steel. If necessary, reaming shall be used to enlarge holes.

When a number of sequential assemblies are necessary because of the length of the bridge, the second and subsequent assemblies shall include at least one section from the preceding assembly to provide continuity of alignment.

Trial assemblies shall be required whether the field-splices are bolted or welded. Each assembly shall be checked for camber, alignment, accuracy of holes, and fit-up of welded joints and milled surfaces. Corrective work, if necessary, shall be carried out at no cost to the Owner.

10.24.6.10 Holes drilled using numerically controlled machinesAs an alternative to the trial assembly specified in Clause 10.24.6.9 when the bolt holes have been prepared by numerically controlled drilling or using a suitable template, the accuracy of the drilling may be demonstrated by a check assembly consisting of the first components of each type to be made. If the check assembly is satisfactory, further assemblies of like components shall not be required.

(Replaces p. 526, November 2006)526

Single user license only. S

torage, distribution or use on network prohibited

Page 52: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

If the check assembly is unsatisfactory for any reason, the work shall be redone or repaired in a manner acceptable to the Owner. Further check assemblies shall be required, as specified by the Owner, to demonstrate that the required accuracy of fit-up has been achieved.

10.24.6.11 Match-markingConnecting parts that are assembled in the shop for reaming or drilling holes shall be match-marked. A drawing shall be prepared to show how the marked pieces should be assembled in the field to replicate the shop assembly.

10.24.7 Tolerances

10.24.7.1 Structural membersStructural members consisting of a single rolled shape shall meet the straightness tolerances of CSA G40.20, except that columns shall not deviate from straight by more than 1/1000 of the length between points of lateral support.

A variation of 1 mm from the detailed length shall be permissible in the length of members that have both ends finished for contact bearing. Other members without finished ends may have a variation from the detailed length of not more than 2 mm for members 10 m or less in length, and not more than 4 mm for members over 10 m in length.

10.24.7.2 Abutting jointsWhen compression members are butted together to transmit loads in bearing, the contact faces shall be milled or saw-cut. The completed joint shall have at least 75% of the entire contact area in full bearing, defined as not more than 0.5 mm separation, and the separation of the remainder shall not exceed 1 mm.

At joints where loads are not transferred in bearing, the nominal dimension of the gap between main members shall not exceed 10 mm, with a tolerance of ±5 mm from the nominal dimension.

10.24.7.3 Facing of bearing surfacesThe surface finish of bearing surfaces that are in contact with each other or with concrete shall meet the roughness requirements specified in CSA B95 and Table 10.19.

Surfaces of flanges that are in contact with bearing sole plates shall be flat within 0.5 mm over an area equal to the projected area of the bearing stiffeners and web. Outside this area, a 2 mm deviation from flat shall be acceptable. The bearing surface shall be perpendicular to the web and bearing stiffeners.

Table 10.19Facing of bearing surfaces roughness requirements

(See Clause 10.24.7.3.)

Contact surfaces

Surface roughness

Micro-inches Microns

Steel slabs or plates in contact with concretePlates in contact as part of bearing assembliesMilled ends of compression membersMilled or ground ends of stiffenersBridge rollers or rockersPins and pin holesSliding bearings — Steel/copper alloy or steel/stainless steel

20001000 500 500 250 125 125

50251313 6 3 3

527(Replaces p. 527, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 53: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.24.7.4 Bearing platesBearing plates shall meet the following requirements:(a) rolled steel bearing plates 50 mm or less in thickness may be used without planing if a satisfactory

contact bearing is obtained;(b) rolled steel bearing plates more than 50 mm thick but not more than 100 mm thick may be

straightened by pressing or by planing on all bearing surfaces to obtain a satisfactory contact bearing; and

(c) rolled steel bearing plates more than 100 mm thick shall be planed on all bearing surfaces, except for those surfaces that are in contact with concrete foundations and are grouted to ensure full bearing.

10.24.7.5 Fabricated componentsThe tolerances for welded components shall comply with Clause 5.4 of CSA W59. The dimensional tolerances of welded structural members shall be those specified in Clauses 5.8 and 12.5.3 of CSA W59.

Built-up, bolted structural members shall comply with the straightness tolerances specified in CSA G40.20 for rolled wide-flanged shapes.

Bearing stiffeners fitted to bear shall have a minimum bearing contact area of 75% and a maximum separation of 1 mm over the remaining area. Fitted intermediate stiffeners shall have a minimum bearing contact area of 25% and a maximum separation of 2 mm.

10.24.8 Quality control

10.24.8.1 Qualification of inspectorsWelding inspectors shall be qualified by the CWB to the requirements of CSA W178.2.

10.24.8.2 Non-destructive testing of weldsAt least the following non-destructive testing of welds shall be performed:(a) visual inspection of all welds;(b) radiographic or ultrasonic inspection of groove welds in flanges and webs of built-up girders, as

follows:(i) flange splices in tension or stress reversal zones: 100%;(ii) flange splices in compression zones: 25%; and(iii) web splices: 100% for one-half of the depth from the tension flange and 25% for the remainder

of the web;(c) magnetic particle inspection of web-to-flange fillet welds, as follows:

(i) submerged-arc welds: 25%;(ii) semi-automatic welds: 50%; and(iii) manual welds: 100%; and

(d) magnetic particle inspection of fillet welds, as follows, for connection plates and stiffeners to which cross-bracing or diaphragms are attached:(i) for one-half of the depth from the tension flange: 100%; and (ii) transverse welds on tension flanges: 100%.

Radiographic and ultrasonic testing shall be performed before assembly of the flanges to the webs.

10.24.8.3 Acceptance standards for weld defectsThe acceptance standards for dynamically loaded structures specified in Clause 12.5.4 of CSA W59 shall apply to weld defects.

10.24.8.4 Repair of weldsWelds that do not meet the acceptance standards specified in Clause 10.24.8.3 shall be removed, rewelded, and retested. Repairs and non-destructive testing of fracture-critical and primary-tension members shall be performed in accordance with Clause 10.23.

(Replaces p. 528, November 2006)528

Single user license only. S

torage, distribution or use on network prohibited

Page 54: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

10.24.8.5 Identification of structural steelIn the fabricator’s plant, the specification and grade of steel used for main components shall be identified by use of suitable markings or recognized colour coding. Cut pieces that are identified by piece mark and contract number need not continue to carry specification identification markings when it has been established that such pieces conform to the required material specifications.

Records shall be kept to identify the heat number of the material and the corresponding mill test report for each component of a fracture-critical or primary tension member.

10.24.9 Transportation and deliveryStructural steel shall be loaded for shipping, transported, unloaded, and stored clear of the ground at its destination without being excessively stressed, deformed, or otherwise damaged. Where possible, plate girders shall be transported with their webs in the vertical plane. Where girders cannot be shipped with their webs in the vertical plane, static and dynamic forces during handling, transport, and storage shall be determined using a dynamic load allowance of at least 100%, unless a lower value can be justified. Computed stresses shall satisfy the provisions of Clause 10.10. Fatigue stresses due to dynamic flexure during transport shall also be considered.

10.24.10 Erection

10.24.10.1 Erection conditionsComponents shall be lifted and placed using appropriate lifting equipment, temporary bracing, guys, or stiffening devices so that they are not overloaded or unstable. Additional permanent material may be provided, if Approved, to ensure that the member capacities are not exceeded during erection.

10.24.10.2 FalseworkAll falsework, including necessary foundations, required for the safe construction of a bridge shall be designed, furnished, maintained, and removed by the contractor. The contractor shall not use any of the material intended for use in the finished bridge for temporary purposes during erection, unless such use is Approved.

10.24.10.3 Removal of temporary bracing or guysTemporary bracing or guys shall be removed when no longer required for the stability of the bridge, unless otherwise Approved.

10.24.10.4 Maintaining alignment and camberThe bridge shall be erected to the proper alignment on plan and in elevation, taking into account the specified dead load camber.

10.24.10.5 Field assemblyParts shall be assembled following the piece marks shown on the erection drawings and match-marks.

Main girder splices and field connections shall have half their holes filled with fitting-up bolts and drift-pins (half bolts and half pins) before the installing and tightening of the balance of the connection bolts. The fitting-up bolts may be the same high-strength bolts used in the installation. The pins shall be 1 mm larger in diameter than the bolts. Excessive drifting that distorts the metal and enlarges the holes shall not be allowed, although reaming up to 2 mm over the nominal hole diameter shall be permitted, except for oversize or slotted holes.

10.24.10.6 Cantilever erectionWhen cantilever erection is used, splices that support the cantilevering member shall be fully bolted before the cantilever is further extended or loaded.

529(Replaces p. 529, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 55: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

10.24.10.7 Repairs to erected materialWith the exception of splices of main material, the correction of minor misfits involving minor amounts of reaming, cutting, and shimming shall be permitted. The correction of other shop fabrication, or any deformation resulting from handling or transportation that prevents the proper assembly and fitting of the parts, shall require Approval.

10.24.10.8 Field weldingAny company undertaking field welding in accordance with this Section shall be certified to Division 1 or 2 of CSA W47.1.

10.24.10.9 AttachmentsTack welds intended to be used for attachments or for any other purpose shall not be used unless they subsequently become a part of the welds shown on the Plans. Tack welds that are not part of the welds shown on the Plans shall not be used on any portion of the girders.

10.24.10.10 Protection of the substructure against stainingThe substructure shall be protected against rust staining by water runoff from the bridge, as specified on the Plans.

(Replaces p. 530, November 2006)530

Single user license only. S

torage, distribution or use on network prohibited

Page 56: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

13.7.6 Hydraulic cylinder connectionsThe loads on the structural connections to the cylinders shall be based on the maximum of(a) wind, ice, inertia, or other structural loads, assuming the cylinder as a rigid link; and(b) driving and braking mechanical loads, assuming a cylinder force developed by 150% of the setting of

the pressure-relief valve that controls the maximum pressure available at the cylinder.

13.7.7 Loads on end floor beams and stringer bracketsThe end floor beams and stringer brackets of the moving span shall be proportioned for at least the factored dead load and factored live load plus twice the factored dynamic load allowance.

13.7.8 Swing bridges — Ultimate limit states

13.7.8.1 Closed positionIn the closed position, the bridge ends are lifted to give a positive reaction equal to 150% of the maximum negative reaction due to live load and dynamic load allowance. For this position, load combinations ULS 1 to ULS 8 of Section 3 shall apply.

13.7.8.2 Special load combinations and load factorsIn addition to load combinations ULS 1 to ULS 8 of Section 3, the special load combinations and load factors specified in Table 13.3 shall be considered.

Table 13.3Swing bridges — Special load combinations and load factors

(See Clauses 13.7.1 and 13.7.8.2.)

Load combination Do* Ls Lc Wo Io Mo

ULS S1ULS S2ULS S3ULS S4ULS S5ULS S6ULS S7

DDDDDDD

01.7001.40000

001.7001.4000

0001.201.201.201.50

1.2000001.201.20

1.5500001.250

*See Table 13.6 for values of D.Notes: (1) When the ends are being lifted, the loading combination and load factors are

similar to ULS S1 except that there are different machinery forces and there are forces at the ends.

(2) For any combination, the minimum or maximum value of the load factor, D , shall be used so as to maximize the total force effect.

Legend: Do = dead load; bridge open in any position or closed with ends just touchingLs = live load (including dynamic load allowance) on one arm as a simple

span; bridge closed with ends just touchingLc = live load (including dynamic load allowance); bridge closed with ends

just touching, with bridge considered as a continuous structure; reactions at both ends to be positive

Wo = wind load; bridge open in any position or closed with ends just touchingIo = operating impact of 20% applied to the maximum dead load effect in all

members that are in motion and to the load effect on a stationary member caused by the moving dead load

Mo = maximum forces on structural parts caused by the operation of machinery, or by forces applied for moving or stopping the span, increased 100% as an allowance for impact

591(Replaces p. 591, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 57: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

13.7.8.3 Stationary in open positionIn the event that a movable bridge is required to remain open or can be stuck in the open position, the requirements of Section 3 for wind loads on a fixed bridge shall apply.

13.7.9 Bascule (including rolling lift) bridges — Ultimate limit states

13.7.9.1 Closed positionWhen the bridge is not in operating mode and the counterweight is not temporarily supported for repairs, load combinations ULS 1 to ULS 8 of Section 3 shall apply.

13.7.9.2 Special load combinations and load factorsIn addition to load combinations ULS 1 to ULS 8 of Section 3, the special load combinations and load factors specified in Table 13.4 shall be considered.

Table 13.4Bascule (including rolling lift) bridges —

Special load combinations and load factors(See Clauses 13.7.1 and 13.7.9.2.)

Load combination Do* Dt* Lt Ho Wo Io Mo

ULS B1ULS B2ULS B3ULS B4ULS B5

DDDD0

0000D

00001.70

0001.550

01.201.5000

1.21.21.21.20

1.551.2501.550

*See Table 13.6 for values of D.Notes: (1) Combination ULS B4 applies only to those parts of the structure that support

trunnions of the moving span and/or counterweight.(2) For any combination, the minimum or maximum value of the dead load factor, D ,

specified in Section 3 shall be used to maximize the total force effects.Legend: Do = dead load; bridge open in any position or closed with ends just touchingDt = dead load; bridge closed; counterweight supported for repairsLt = live load (including dynamic load allowance); bridge closed; counterweight

supported for repairsHo = horizontal force, taken as 5% of the total moving load carried by the steel

towers and/or special parts of the structure that support the counterweight assembly; bridge open in any position; this force shall be applied in any direction, through the centre of gravity of the moving load

Wo = wind load; bridge open in any position or closed with ends just touchingIo = operating impact of 20% applied to the maximum dead load effect in all

members that are in motion and to the load effect on a stationary member caused by the moving dead load

Mo = maximum forces on structural parts caused by the operation of machinery, or by forces applied for moving or stopping the span, increased 100% as an allowance for impact

(Replaces p. 592, November 2006)592

Single user license only. S

torage, distribution or use on network prohibited

Page 58: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

13.7.10 Vertical lift bridges — Ultimate limit states

13.7.10.1 Closed positionWhen the bridge is not in operating mode and the counterweight is not temporarily supported for repairs, load combinations ULS 1 to ULS 8 of Section 3 shall apply.

13.7.10.2 Special load combinations and load factorsIn addition to load combinations ULS 1 to ULS 8 of Section 3, the special load combinations and load factors specified in Table 13.5 shall be considered.

Table 13.5Vertical lift bridges — Special load combinations and load factors

(See Clauses 13.7.1 and 13.7.10.2.)

13.7.11 Dead load factorThe dead load factor, D , in Tables 13.3 to 13.5 shall be as specified in Table 13.6.

Table 13.6Dead load factor, D

(See Clause 13.7.11 and Tables 13.3–13.5.)

Load combination Do* Dt* Lt Wo Io Mo

ULS V1ULS V2ULS V3ULS V4

DDD0

000D

0001.70

0 1.20 1.500

1.21.21.20

1.551.2500

*See Table 13.6 for values of D.Note: For any combination, the minimum or maximum value of the dead load factor, D , shall be used to maximize the total force effects.Legend: Do = dead load; bridge open in any position or closed with ends just

touchingDt = dead load; bridge closed; counterweight supported for repairsLt = live load (including dynamic load allowance); bridge closed;

counterweight supported for repairsWo = wind load; bridge open in any position or closed with ends just

touchingIo = operating impact of 20% applied to the maximum dead load effect

in all members that are in motion and to the load effect on a stationary member caused by the moving dead load

Mo = maximum forces on structural parts caused by the operation of machinery, or by forces applied for moving or stopping the span, increased 100% as an allowance for impact

Dead load type Maximum Minimum

D1 — Factory-produced componentsD2 — Cast-in-place concrete and woodD3 — Wearing surface

1.201.401.40

0.900.800.75

593(Replaces p. 593, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 59: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

13.7.12 All movable bridges — Ultimate limit statesLongitudinal wind shall be included in the design of the superstructure for load combinations ULS 3, ULS 4, and ULS 7 of Section 3. For seismic loading with the bridge open, load combination ULS 5 of Section 3, as modified by Clause 13.7.4, shall apply. For vessel collisions with the bridge operating, load combination ULS 8 of Section 3 shall apply.

13.7.13 Special types of movable bridgesThe analysis of special types of movable bridges shall be carried out for all applicable load conditions. The members shall be proportioned for total factored load effects in accordance with the requirements specified in this Section for the design of fixed, swing, bascule, and vertical lift bridges.

13.7.14 Load effectsA drawing shall be prepared showing the load effects for the various analyses and the total factored load effects for the applicable combinations in the different primary members at appropriate locations.

13.7.15 Fatigue limit stateThe stress range arising from the operation of the span from the fully closed to the fully open position and back to the fully closed position, including the effect of wind, shall be less than the allowable stress range specified in Section 10, based on the estimated number of load cycles.

This Clause shall also apply to members and/or steel that are embedded in or encase counterweights and either support the mass or transfer the load to the main structure, and to the connections of such members.

13.7.16 FrictionConsideration shall be given to bending stresses arising from pin, journal, trunnion, and other friction.

13.7.17 Machinery supportsAll structural parts supporting machinery shall be of ample strength and rigidity and be designed to minimize vibration.

13.7.18 Vertical lift bridge towersThe lateral bracing of vertical lift bridge towers shall be designed for 2.5% of the total compression in the columns in addition to the specified wind loads.

13.7.19 Transitory loadsTransitory loads, e.g., operating impact, shall be included in the loading combinations only if their inclusion increases the total factored load effect.

13.8 Mechanical system design

13.8.1 GeneralBecause mechanical system design in North America is based mainly on working stress design, the requirements of Clauses 13.8.2 to 13.8.20 are specified in terms of working stress even though other clauses of this Code are based on limit states design.

Most North American textbooks on mechanical system design use foot/pound units. Accordingly, where a value was originally expressed in foot/pound units, Clause 13.8 provides the foot/pound value in parentheses, accompanied by a soft-converted SI value.

(Replaces p. 594, November 2006)594

Single user license only. S

torage, distribution or use on network prohibited

Page 60: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Section 14 — Evaluation

14.1 Scope 64314.2 Definitions 64314.3 Symbols 64314.4 General requirements 64614.4.1 Exclusions 64614.4.2 Expertise 64614.4.3 Future growth of traffic or future deterioration 64714.4.4 Scope of evaluation 64714.5 Evaluation procedures 64714.5.1 General 64714.5.2 Limit states 64714.5.3 Deleted14.5.4 Evaluation methodology 64814.5.5 Bridge posting 64814.6 Condition inspection 64814.6.1 General 64814.6.2 Plans 64914.6.3 Physical features 64914.6.4 Deterioration 64914.7 Material strengths 64914.7.1 General 64914.7.2 Review of original construction documents 64914.7.3 Analysis of tests of samples 64914.7.4 Strengths based on date of construction 65014.7.5 Deteriorated material 65114.8 Permanent loads 65114.8.1 General 65114.8.2 Dead load 65114.8.3 Earth pressure and hydrostatic pressure 65214.8.4 Shrinkage, creep, differential settlement, and bearing friction 65214.8.5 Secondary effects from prestressing 65214.9 Transitory loads 65214.9.1 Normal traffic 65214.9.2 Permit — Vehicle loads 65614.9.3 Dynamic load allowance for permit vehicle loads and alternative loading 65714.9.4 Multiple-lane loading 65714.9.5 Loads other than traffic 65814.10 Exceptional loads 65914.11 Lateral distribution categories for live load 65914.11.1 General 65914.11.2 Statically determinate method 65914.11.3 Sophisticated method 65914.11.4 Simplified method 65914.12 Target reliability index 65914.12.1 General 65914.12.2 System behaviour 66014.12.3 Element behaviour 66014.12.4 Inspection level 66014.12.5 Important structures 66014.13 Load factors 66114.13.1 General 661

641(Replaces p. 641, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 61: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

14.13.2 Permanent loads 66214.13.3 Transitory loads 66214.14 Resistance 66514.14.1 General 66514.14.2 Resistance adjustment factor 67214.14.3 Effects of defects and deterioration 67314.15 Live load capacity factor 67414.15.1 General 67414.15.2 Ultimate limit states 67414.15.3 Serviceability limit states 67514.15.4 Combined load effects 67514.16 Load testing 67514.16.1 General 67514.16.2 Instrumentation 67614.16.3 Test load 67614.16.4 Application of load test results 67614.17 Bridge posting 67714.17.1 General 67714.17.2 Calculation of posting loads 67714.17.3 Posting signs 67814.18 Fatigue 679

AnnexesA14.1 (normative) — Equivalent material strengths from tests of samples 680A14.2 (normative) — Evaluation Level 1 (vehicle trains) in Ontario 682A14.3 (normative) — Evaluation Level 2 (two-unit vehicles) in Ontario 683A14.4 (normative) — Evaluation Level 3 (single-unit vehicles) in Ontario 684

(Replaces p. 642, November 2006)642

Single user license only. S

torage, distribution or use on network prohibited

Page 62: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

P = posting factor

Pn = unfactored resistance of a masonry arch, kN

Pr = factored resistance of a masonry arch, kN

q = average percentage of tensile reinforcement in the two directions in which steel is placed at the midspan of a slab panel (see Clause 14.14.1.3.3); uniformly distributed portion of lane load, kN/m

R = nominal unfactored resistance, kN, calculated using the material strengths as specified in Clause 14.7.1 and in accordance with the requirements of Sections 6 to 12 and Clause 14.14 (see Clause 14.15.2.3)

R = mean resistance, kN

REL1 = loss of prestress due to relaxation of prestressing steel prior to transfer, MPa

REL2 = loss of prestress due to relaxation of prestressing steel after transfer, MPa

Rd = nominal resistance of a concrete deck slab, kN

Rn = unfactored (nominal) resistance of a concrete deck slab, kN

Rr = factored resistance of structural component, kN

SD = standard deviation of dead load force effects

SL = standard deviation of live load force effects

SH = loss of prestress due to shrinkage of concrete, MPa

s = spacing of stirrups measured parallel to the longitudinal axis of a component, mm

sm1 = maximum allowable spacing below which a section is considered to have full transverse reinforcement, mm

sm2 = maximum allowable spacing above which a section is considered not to have transverse reinforcement, mm

sr1 = maximum allowable spacing, as a fraction of shear depth, below which the section is considered to have transverse reinforcement

sr2 = maximum allowable spacing, as a fraction of shear depth, above which the section is considered not to have transverse reinforcement

Tf = tensile force in a member or component at the ultimate limit state, N

Tr = factored tensile resistance of a riveted joint, N

t = thickness of a steel component, mm; thickness of a concrete deck slab, mm; time, d

U = resistance adjustment factor

V = coefficient of variation

VAD = coefficient of variation for dead load analysis method

VAL = coefficient of variation for live load analysis method

VD = coefficient of variation for dead load

VI = coefficient of variation for dynamic load allowance

VL = coefficient of variation for live load

VR = coefficient of variation for resistance

VS = coefficient of variation for total load

Vf = shear force at the ultimate limit state, N

Vp = component in the direction of the applied shear of all of the effective prestressing forces crossing the critical section factored by p , the resistance factor for tendons in Clause 8.4.6 (taken as positive if resisting the applied shear), N

Vr = factored shear resistance of a riveted joint, N

W = gross vehicle weight, kN

645(Replaces p. 645, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 63: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

A = load factors for force effects due to additional loads (including wind, creep, shrinkage, temperature, and differential settlement) that may be considered in the evaluation

D = load factors for force effects due to dead loads

L = load factors for force effects due to live loads

= target reliability index

AD = bias coefficients (ratio of mean to nominal effects) for dead load analysis method

AL = bias coefficients (ratio of mean to nominal effects) for live load analysis method

D = bias coefficients (ratio of mean to nominal effects) for dead load

I = bias coefficients (ratio of mean to nominal effects) for dynamic load allowance

L = bias coefficients (ratio of mean to nominal effects) for live load

R = bias coefficients (ratio of mean to nominal effects) for resistance

µp = ratio of area of prestressed reinforcement to area of concrete

= reinforcement ratio of tensile reinforcement

b = reinforcement ratio producing balanced conditions — when the tension reinforcement reaches its yield strain just as the concrete compression reaches a strain of 0.0035 — used in the calculation of U

A = unfactored stress due to additional loads (including wind, creep, shrinkage, temperature, and differential settlement) that may be considered in the evaluation, MPa

D = unfactored dead load stress, MPa

L = unfactored live load stress, MPa

SLS = serviceability limit state stress, MPa

= resistance factor

c = resistance factor for concrete (see Clause 8.4.6)

mc = member resistance factor for a riveted connection

md = member resistance factor for a reinforced concrete deck slab

mm = member resistance factor for a masonry component

r = material resistance factor for rivet steel

p = mechanical reinforcement ratio for prestressing steel

14.4 General requirements

14.4.1 ExclusionsThis Section shall not be used to determine whether a bridge or bridge design complies with the design requirements of Sections 1 to 13 and 16.

Pedestrian bridges, railings, barrier walls, foundations, and retaining walls shall be evaluated in accordance with the design requirements of this Code.

This Section does not address loads caused by earthquakes, fires, floods, ice, and vehicle and vessel collisions.

This Section shall not be used unless the bridge is secure against causes of failure other than traffic loading. Loads other than traffic shall be considered in accordance with other Sections of this Code, except as required by Clause 14.9.5.

This Section shall not be used for buried structures.

14.4.2 ExpertiseEvaluations in accordance with this Section shall be performed and checked by suitably qualified Engineers, and shall be reviewed by an experienced bridge Engineer, who may also be one of the persons performing or checking the evaluation.

(Replaces p. 646, November 2006)646

Single user license only. S

torage, distribution or use on network prohibited

Page 64: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

14.4.3 Future growth of traffic or future deteriorationNo allowance is made in this Section for future growth of traffic or for future deterioration of the bridge. If such changes are anticipated, they shall be considered in the evaluation. If any change in traffic or in the condition of the bridge that has not been accounted for occurs, the evaluation shall be reviewed and, if necessary, the bridge shall be re-evaluated.

14.4.4 Scope of evaluationThe scope of the evaluation shall be determined in consultation with the Owner, with particular care exercised for single load path structures with brittle failure modes.

14.5 Evaluation procedures

14.5.1 GeneralThe procedures in this Section shall be used when bridges are to be evaluated for load limit restrictions, serviceability, or fatigue loadings.

A bridge shall be evaluated in accordance with one or more of the following methods:(a) ultimate limit states methods (except for masonry abutments, masonry piers, and masonry retaining

walls). The following shall be considered acceptable methods:(i) ultimate limit states methods in accordance with Clauses 14.15.2.1 and 14.15.2.2, using load

and resistance adjustment factors specified in Clauses 14.13 and 14.14;(ii) the mean load method for ultimate limit states specified in Clause 14.15.2.3; and(iii) the load testing method specified in Clause 14.16;

(b) serviceability limit states methods; and(c) other Approved methods.

14.5.2 Limit states

14.5.2.1 GeneralThe limit states for which a bridge is to be evaluated shall be selected from Clauses 14.5.2.2 to 14.5.2.4.

14.5.2.2 Ultimate limit statesUltimate limit states shall be used in determining the load-carrying capacity, stability, and load posting of bridges, except as specified in Clause 14.5.2.3.

14.5.2.3 Serviceability limit statesServiceability limit states shall be used in determining the load-carrying capacity, stability, and load posting of masonry abutments, masonry piers, and masonry retaining walls, in accordance with Clause 14.15.3.

For a bridge where cracking, deformation, stresses, or vibrations are detrimental to the structure, expected, or evident, the bridge and its affected components shall be evaluated for serviceability limit states requirements in accordance with the applicable Sections of this Code.

Where there is no evidence of serviceability-related defects, the evaluation need not consider the serviceability limit state if neither the use nor the behaviour of the bridge is changed.

14.5.2.4 Fatigue limit stateEvaluations for the fatigue limit state shall be carried out in accordance with Clause 14.18.

647(Replaces p. 647, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 65: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

14.5.2.5 — Deleted

14.5.3 — Deleted

14.5.4 Evaluation methodology

14.5.4.1 GeneralThe following requirements shall apply to the evaluation of bridges in accordance with this Section:(a) a condition inspection of the structure shall be conducted in accordance with Clause 14.6;(b) material strengths shall be determined in accordance with Clause 14.7;(c) loads shall be defined in accordance with Clauses 14.8 to 14.10; and(d) lateral distribution of live load shall be categorized in accordance with Clause 14.11.

14.5.4.2 Evaluation at ultimate limit states using load and resistance factorsThe following requirements shall apply to the evaluation at ultimate limit states using load and resistance factors:(a) the target reliability index, , shall be selected in accordance with Clause 14.12.1;(b) the load factors shall be selected in accordance with Clause 14.13;(c) the resistances shall be calculated in accordance with Clause 14.14; and(d) the live load capacity factor, F, shall be determined in accordance with Clause 14.15.

14.5.4.3 Evaluation at serviceability limit statesFor evaluation at serviceability limit states, the live load capacity factor, F, shall be determined in accordance with Clause 14.15.3.

14.5.4.4 Evaluation by use of mean load methodThe following requirements shall apply to evaluation by use of the mean load method:(a) the target reliability index, , shall be selected in accordance with Clause 14.12.1;(b) nominal (unfactored) resistances shall be calculated in accordance with Sections 6 to 12 or

Clause 14.14 by taking all resistance factors, , as having a value of 1.0; and(c) the live load capacity factor, F, shall be determined in accordance with Clause 14.15.2.3.

14.5.4.5 Evaluation by load testingThe following requirements shall apply to evaluation by load testing:(a) the bridge shall be evaluated in accordance with Clause 14.5.4.2, 14.5.4.3, or 14.5.4.4;(b) the bridge shall be tested in accordance with Clause 14.16; and(c) the live load capacity factor, F, shall be determined in accordance with Clause 14.16.4.2.

14.5.5 Bridge postingIf a bridge needs to be posted for load restriction based on the load capacity factor calculated in accordance with Clause 14.15 or 14.16, the posting loads shall be in accordance with Clause 14.17.

14.6 Condition inspection

14.6.1 GeneralA condition inspection of the bridge shall be carried out to the satisfaction of the evaluator. Inspection records shall be sufficiently detailed to allow changes in condition to be assessed during future inspections.

(Replaces p. 648, November 2006)648

Single user license only. S

torage, distribution or use on network prohibited

Page 66: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

14.6.2 PlansThe evaluator shall verify that the available Plans accurately represent the dimensions, member sizes, and other essential geometric features of the structure, for the original construction and subsequent rehabilitations and modifications. If no Plans are available, measurements shall be made with sufficient precision to suit the intended purpose.

14.6.3 Physical featuresAll physical features of a bridge that affect its structural integrity shall be examined.

14.6.4 DeteriorationAll flawed, damaged, distorted, or deteriorated regions shall be identified, and sufficient data shall be collected so that these defects can be properly considered in the evaluation.

14.7 Material strengths

14.7.1 GeneralThe strengths of materials that do not have visible signs of deterioration shall be determined using one of the following methods:(a) review of Plans and other documents in accordance with Clause 14.7.2;(b) analysis of tests of samples obtained from the bridge or from specific bridge components in

accordance with Clause 14.7.3;(c) estimation by considering the date of bridge construction in accordance with Clause 14.7.4; or(d) an Approved method.

14.7.2 Review of original construction documents

14.7.2.1 GeneralThe Plans and other relevant contract documents may be reviewed to determine(a) the specified minimum yield strength of structural steel;(b) the specified compressive strength of concrete;(c) the specified minimum yield strength of reinforcing steel;(d) the specified tensile strength of prestressing steel;(e) the species and grade of wood; and(f) the type of stone and grade of mortar used in masonry construction.

14.7.2.2 Mill certificatesActual values of yield and ultimate tensile stresses reported on mill certificates shall not be used for evaluation. Instead, the strength used shall be the guaranteed minimum value specified for the grade of steel shown on the certificate.

14.7.3 Analysis of tests of samples

14.7.3.1 GeneralNominal material strengths to be used in the calculation of member resistances may be determined by testing samples obtained from the bridge. Samples shall not be removed from locations where the strength, stability, or integrity of the member might be adversely affected. The location and orientation of each sample shall be recorded, as well as any additional information that could later be useful in interpretation of the test results.

649(Replaces p. 649, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 67: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

Material strength values obtained by testing shall not be directly substituted into the equations for resistance specified in this Code. Test results shall be converted to nominal material strengths in accordance with Annex A14.1 or an Approved method.

14.7.3.2 Prestressing steelRemoval of prestressing steel specimens for testing shall not jeopardize the safety of the structure or be hazardous to the personnel involved. Specimens shall be tested in accordance with CSA G279.

14.7.3.3 WoodIn lieu of obtaining wood samples for testing, the species and grade shall be identified by a wood grader.

14.7.3.4 Masonry mortarMortar in joints shall be sampled or tested to obtain the compressive strength. The mortar shall be classified as one of the following types:(a) hard mortar — compressive strength greater than 7 MPa;(b) medium mortar — compressive strength between 2 and 7 MPa; or(c) soft mortar — compressive strength less than 2 MPa.

The allowable limit state stress at the serviceability limit state in shear and compression shall be determined using a rational method based on the classification of the mortar, the thickness of the mortar joint, and the type of stone used in the masonry.

14.7.4 Strengths based on date of construction

14.7.4.1 GeneralIn the absence of more specific information, preliminary evaluation may be based on material strengths estimated by considering the date of bridge construction.

14.7.4.2 Structural steelIf Plans and mill certificates are not available, and coupons have not been taken for testing, the values specified in Table 14.1 shall be used for structural steel.

Table 14.1Properties of structural steel

(See Clause 14.7.4.2.)

14.7.4.3 ConcreteIf Plans and specifications are not available and cores have not been obtained, the compressive strength of concrete with no visible signs of deterioration shall be taken as 15 MPa for the substructure, 20 MPa for the superstructure, and 25 MPa for prestressed concrete components.

14.7.4.4 Reinforcing steelIf Plans and mill certificates are not available and specimens have not been tested, the values specified in Table 14.2 shall be used for reinforcing steel.

Date of bridge constructionSpecifiedFy , MPa

SpecifiedFu , MPa

Before 19051905–19321933–1975After 1975

180210230250

360420420420

(Replaces p. 650, November 2006)650

Single user license only. S

torage, distribution or use on network prohibited

Page 68: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Table 14.2Minimum yield strengths of reinforcing steel, MPa

(See Clause 14.7.4.4.)

14.7.4.5 Prestressing steelIf Plans and mill certificates are not available and specimens have not been tested, the tensile strength of prestressing steel shall be taken as 1600 MPa for bridges constructed before 1963 and 1725 MPa for bridges constructed later.

14.7.4.6 RivetsIf Plans and mill certificates are not available, the following values for the ultimate tensile strength of rivets shall be used:(a) rivets constructed to ASTM A 7-39, constructed before 1936, or of unknown origin: Fu = 320 MPa;

and(b) rivets constructed to CESA S42-1935, CSA G40.2-1959, ASTM A 141-33, ASTM A 141-39, or

ASTM A 502-65, or constructed after 1935 but of unknown origin: Fu = 360 MPa.

14.7.5 Deteriorated materialDeteriorated material shall be assessed in accordance with Clause 14.14.3. Non-destructive test methods, such as ultrasonic pulse velocity and surface hardness methods, may be used to correlate the concrete strength in damaged and sound regions of a structure. If compressive strengths are estimated using non-destructive methods, calibration factors shall be determined using concrete cores from the structure, and their uncertainty shall be accounted for in the estimate of predicted strengths.

14.8 Permanent loads

14.8.1 GeneralThe evaluation of the load-carrying capacity of existing bridges shall take into consideration all permanent loads except as specified in Clause 14.8.4.

14.8.2 Dead load

14.8.2.1 GeneralDead load shall include the weight of all components of the bridge, fill, utilities, and other materials permanently on the bridge. Dead loads shall be determined from available Plans and verified with field measurements in accordance with Clause 14.6.

Dead load shall be apportioned to three categories, D1, D2, and D3, as follows:(a) D1: dead load of factory-produced components and cast-in-place concrete, excluding decks;(b) D2: cast-in-place concrete decks (including voided decks and cementitious concrete overlays), wood,

field-measured bituminous surfacing, and non-structural components; and(c) D3: bituminous surfacing where the nominal thickness is assumed to be 90 mm for the evaluation.

Date of bridgeconstruction

Grade

StructuralMedium or intermediate Hard Unknown

Before 19141914–19721973–1978After 1978

—230275300

—275345350

—345415400

210230275300

651(Replaces p. 651, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 69: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

14.8.2.2 Dead load distributionThe transverse distribution of dead load shall be in accordance with Section 5.

14.8.3 Earth pressure and hydrostatic pressureEarth pressure and hydrostatic pressure shall be considered in the evaluation, treated as permanent loads, and multiplied by a load factor in accordance with Clause 14.13.2.2.

14.8.4 Shrinkage, creep, differential settlement, and bearing frictionShrinkage, creep, differential settlement, and bearing friction need not be considered in evaluation at ultimate limit states if their effects induce ductile behaviour. When their effects induce non-ductile behaviour, they shall have load factors determined in accordance with Clause 14.13.2.3.

14.8.5 Secondary effects from prestressingSecondary effects from prestressing shall be considered as permanent loads and multiplied by load factors in accordance with Clause 3.5.1.

14.9 Transitory loads

14.9.1 Normal traffic

14.9.1.1 GeneralBridges shall be evaluated for the following:(a) a vehicle train, a two-unit vehicle, and a single-unit vehicle, as specified in Clause 14.9.1.2, 14.9.1.3,

and 14.9.1.4, respectively; or(b) alternative loading based on local traffic, as specified in Clause 14.9.1.6.

Truck axles and portions of uniformly distributed lane load that reduce the load effect shall be neglected.

14.9.1.2 Evaluation Level 1 (vehicle trains)A bridge required to carry vehicle trains in normal traffic shall be evaluated to Evaluation Level 1, for which the live load model shall be the CL1-W Truck or Lane Load shown in Figure 14.1, where W is the gross vehicle weight in kilonewtons of a vehicle train legally permitted on bridges without a permit.

The value of W shall be taken as 625 unless the Regulatory Authority uses lesser or greater values of W where traffic conditions are expected to differ from the norm.

In Ontario, the load used for Evaluation Level 1 shall be the CL1-625-ONT Truck Load or CL1-625-ONT Lane Load specified in Annex A14.2.

14.9.1.3 Evaluation Level 2 (two-unit vehicles)A bridge shall be evaluated to Evaluation Level 2 when load restrictions are to be applied and the bridge is required to carry two-unit vehicles. The live load model shall be the CL2-W Truck or Lane Load shown in Figure 14.2, where W is as specified in Clause 14.9.1.2.

In Ontario, the load used for Evaluation Level 2 shall be the CL2-625-ONT Truck Load or the CL2-625-ONT Lane Load specified in Annex A14.3.

14.9.1.4 Evaluation Level 3 (single-unit vehicles)A bridge shall be evaluated to Evaluation Level 3 when load restrictions are to be applied and the bridge is required to carry single-unit vehicles. The live load model shall be the CL3-W Truck or Lane Load shown in Figure 14.3, where W is as specified in Clause 14.9.1.2.

In Ontario, the load used for Evaluation Level 3 shall be the CL3-625-ONT Truck Load or the CL3-625-ONT Lane Load specified in Annex A14.4.

(Replaces p. 652, November 2006)652

Single user license only. S

torage, distribution or use on network prohibited

Page 70: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

14.9.2.4 Permit — Controlled (PC)PC traffic shall include the vehicles authorized by permit to carry an indivisible load on a specified route under supervision and specified travel conditions. The weights and spacings of the axles shall be verified by measurement.

Lane load need not be considered for PC traffic if other traffic is excluded from the bridge during passage of the PC vehicle.

14.9.2.5 Permit — Single trip (PS)PS traffic shall include vehicles authorized by permit for a single trip to carry an indivisible load, mixed with other traffic without supervision. Axle loads and the gross vehicle weight may exceed the non-permit legislated limits.

For the lane carrying the PS vehicle, the load effect shall be calculated from the more severe of(a) the permit vehicle alone in the lane with dynamic load allowance, in accordance with Clause 14.9.3;

or(b) 85% of the permit vehicle, plus a superimposed uniformly distributed load of 9, 8, 7, and 7 kN/m for

highway classes A, B, C, and D, respectively, without dynamic load allowance for either Truck or uniformly distributed loads.

14.9.3 Dynamic load allowance for permit vehicle loads and alternative loadingThe dynamic load allowance for permit vehicle loads shall be as specified in Clause 3.8.4.5, except the dynamic load allowance specified in Clause 3.8.4.5.3(c) shall be taken as 0.30 for tandems, tridems, two-axle groups, and the axle group consisting of the front axle and drive axles.

For a permit vehicle crossing the bridge at a restricted speed, the dynamic load allowance so calculated shall be multiplied by(a) 0.30 for a vehicle speed of 10 km/h or less;(b) 0.50 for a vehicle speed greater than 10 km/h and less than or equal to 25 km/h;(c) 0.75 for a vehicle speed greater than 25 km/h and less than or equal to 40 km/h; and(d) 1.00 for a vehicle speed greater than 40 km/h.

14.9.4 Multiple-lane loading

14.9.4.1 Design lanesThe number of loaded lanes shall be determined in accordance with the current or intended use of the bridge. Where the traffic lanes are clearly designated on the bridge, they shall be used as design lanes, except that outer lanes shall include the adjacent shoulders.

14.9.4.2 Normal trafficThe modification factors for multiple-lane loading shall be as specified in Table 14.3.

657(Replaces p. 657, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 71: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

Table 14.3Modification factors for multiple-lane loading

(See Clause 14.9.4.2.)

14.9.4.3 Permit vehicle with normal trafficWhen the permit vehicle is allowed to travel with normal traffic, the loading to be applied in the other lanes shall be taken as a fraction of the CL1-W loading or CL1-625-ONT loading, as specified in Table 14.4.

Table 14.4Fraction of CL1-W loading to be applied in the other lanes

(See Clause 14.9.4.3.)

14.9.5 Loads other than traffic

14.9.5.1 Sidewalk loadingExcept for sidewalk components, sidewalk loading shall not be considered coincident with traffic loading unless the evaluator has reason to suppose that significant sidewalk loading will occur coincident with maximum traffic loading, in which case the pedestrian loading specified in Clause 3.8.9 shall be used with the same load factor specified in Clause 14.13.3 for traffic.

14.9.5.2 Snow loadsIf significant snow loading on sidewalks is expected, it shall be considered in the evaluation.

14.9.5.3 Wind loadsWind loads are not specifically considered in this Section. If the evaluator considers that significant wind forces could occur simultaneously with the maximum traffic loads, these wind forces shall be considered in accordance with Clause 3.10.

14.9.5.4 Temperature effectsTemperature effects need not be considered at ultimate limit states for any element that will behave in a ductile manner. When non-ductile behaviour is expected, temperature effects shall be considered in accordance with Clause 3.9.4.

Number of lanes loaded

Highway class

A B C or D

123456 or more

1.000.900.800.700.600.55

1.000.900.800.70——

1.000.850.70———

Highway class

A B C or D

Second loaded laneThird and subsequent loaded lanes

0.70.4

0.60.4

0.50.4

(Replaces p. 658, November 2006)658

Single user license only. S

torage, distribution or use on network prohibited

Page 72: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

14.9.5.5 Secondary effectsSecondary effects (excluding secondary effects from prestressing) need not be considered in evaluation at ultimate limit states if their effects induce ductile behaviour. When secondary effects induce non-ductile behaviour, they shall be considered and multiplied by a load factor in accordance with Clause 3.5.1.

14.9.5.6 — Deleted

14.10 Exceptional loadsLoads (other than traffic loads) that occur on rare occasions and are of significant magnitude shall be considered exceptional loads and shall be evaluated in accordance with Sections 1 to 13 and 16 or, when not covered by Sections 1 to 13 and 16, in accordance with good engineering practice.

14.11 Lateral distribution categories for live load

14.11.1 GeneralThe method to be used in calculating the lateral distribution of live loads to the elements considered shall be categorized as statically determinate, sophisticated, or simplified in accordance with Clauses 14.11.2 to 14.11.4.

14.11.2 Statically determinate methodIn this method the lateral distribution is statically determinate.

14.11.3 Sophisticated methodIn this method the lateral distribution is statically indeterminate and is calculated in accordance with a sophisticated method of analysis such as the grillage analogy, orthotropic plate theory, finite element, finite strip, or folded plate method.

14.11.4 Simplified methodIn this method the lateral distribution is calculated in accordance with the simplified methods of Section 5. However, it is possible that the methods specified in Section 5 will not be suitable for non-standard bridges or permit vehicle loads (especially those that are wider than the CL-W vehicles), in which cases such methods shall not be used.

14.12 Target reliability index

14.12.1 GeneralFor all evaluation levels, the target reliability index, , shall be taken from Table 14.5 for PA, PB, and PS traffic and Table 14.6 for PC traffic. In both cases, the system behaviour, element behaviour, and inspection level shall be as specified in Clauses 14.12.2 to 14.12.4.

659(Replaces p. 659, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 73: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

14.12.2 System behaviourSystem behaviour shall take into consideration the effect of any existing deterioration and shall be classified into one of the following categories:(a) Category S1, where element failure leads to total collapse. This includes failure of main members with

no benefit from continuity or multiple-load paths, e.g., a simply supported girder in a two-girder system.

(b) Category S2, where element failure probably will not lead to total collapse. This includes main load-carrying members in a multi-girder system or continuous main members in bending.

(c) Category S3, where element failure leads to local failure only. This includes deck slabs, stringers, and bearings in compression.

14.12.3 Element behaviourElement behaviour shall take into consideration the effect of any existing deterioration and shall be classified into one of the following categories:(a) Category E1, where the element being considered is subject to sudden loss of capacity with little or

no warning. This can include failure by buckling, concrete in shear and/or torsion with less than the minimum reinforcement required by Clause 14.14.1.6.2(a), bond (pullout) failure, suspension cables, eyebars, bearing stiffeners, over-reinforced concrete beams, connections, concrete beam-column compression failure, and steel in tension at net section.

(b) Category E2, where the element being considered is subject to sudden failure with little or no warning but will retain post-failure capacity. This can include concrete in shear and/or torsion with at least the minimum reinforcement required by Clause 14.14.1.6.2(a), and steel plates in compression with post-buckling capacity.

(c) Category E3, where the element being considered is subject to gradual failure with warning of probable failure. This can include steel beams in bending or shear, under-reinforced concrete in bending, decks, and steel in tension at gross section.

14.12.4 Inspection levelEvaluation shall not be undertaken without inspection. Inspection levels shall be classified as follows:(a) Inspection Level INSP1, where a component is not inspectable. This can include hidden members not

accessible for inspection, e.g., interior webs of adjacent box beams.(b) Inspection Level INSP2, where inspection is to the satisfaction of the evaluator, with the results of

each inspection recorded and available to the evaluator.(c) Inspection Level INSP3, where the evaluator has directed the inspection of all critical and substandard

components and final evaluation calculations account for all information obtained during this inspection.

14.12.5 Important structuresFor structures that can affect the life or safety of people under or near a bridge, are essential to the local economy, or are designated as emergency route bridges (in accordance with Clause 4.4.2), a value of greater than that specified in Table 14.5 or 14.6 shall be used if directed by the Regulatory Authority.

(Replaces p. 660, November 2006)660

Single user license only. S

torage, distribution or use on network prohibited

Page 74: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

14.14 Resistance

14.14.1 General

14.14.1.1 GeneralThe factored resistances of concrete, structural steel, and wood components shall be determined in accordance with the applicable Sections of this Code. Components that do not meet the limitations on which the resistance calculations of this Code are based shall have their resistances calculated in accordance with alternative procedures based on established and generally recognized theories, analyses, and engineering judgment.

14.14.1.2 Prestressed concrete using stress-relieved strand or wire

14.14.1.2.1 GeneralThe requirements of Section 8 for low-relaxation strand or wire shall be followed for the evaluation of prestressed concrete bridges using stress-relieved strand or wire, except as modified by Clauses 14.14.1.2.2 to 14.14.1.2.4.

14.14.1.2.2 Prestressing steel stress limitationsStresses at jacking or transfer shall be based on data given on the Plans. In the absence of such data, the following stress limitations, for both pretensioning and post-tensioning, shall be used:(a) at jacking: 0.80fpu ; and(b) at transfer: 0.70fpu .

14.14.1.2.3 Loss of prestress

14.14.1.2.3.1 At transferIn pretensioned components, the relaxation loss in prestressing steel, REL1, initially stressed in excess of 0.5fpu shall be calculated as follows:

RELt f

ffsj

pysj1

2410

0 55= ( ) −⎡

⎣⎢⎢

⎦⎥⎥

log.

14.14.1.2.3.2 After transferThe loss of prestress due to relaxation after transfer, REL2 , shall be calculated as follows:

RELff

CR SHf

fst

pu pu2 0 52 0 42

1 25= −

⎣⎢⎢

⎦⎥⎥

− +⎡

⎣⎢⎢

⎦⎥⎥

⎣⎢⎢

⎦⎥⎥

. .. ppu puf≥ 0 01.

14.14.1.2.4 Prestressing steel stress at the ultimate limit stateThe steel stress, fps , at the ultimate limit state in bonded prestressing steel shall be calculated using a method based on sectional strain compatibility and using stress-strain curves representative of the steel, except that if fse 0.5fpu , the value of fps may be calculated as follows:

f ff

fps pup pu

c= −

′⎡

⎣⎢

⎦⎥1 0 5.

m

665(Replaces p. 665, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 75: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

14.14.1.3 Concrete deck slabs

14.14.1.3.1 GeneralWhen the concrete deck slab is at least 175 mm thick and the requirements for the empirical design method in accordance with Clause 8.18.4 are satisfied, the deck slab shall be deemed to have adequate resistance for the CL loadings specified with a value of W not greater than 625 kN in Clauses 14.9.1.2 to 14.9.1.4. When the concrete deck slab is less than 175 mm thick, W is greater than 625 kN, or the requirements of Clause 8.18.4 are not satisfied, an evaluation of the deck slab shall be carried out in accordance with Clauses 14.14.1.3.2 and 14.14.1.3.3.

14.14.1.3.2 Method of analysisIf all of the conditions specified in Items (a) to (e) are satisfied, the factored resistance shall be determined in accordance with the simplified method specified in Clause 14.14.1.3.3; otherwise, the resistance shall be determined in accordance with Section 8 and expressed as an equivalent wheel load:(a) the centre-to-centre spacing of the supporting beams for a slab panel does not exceed 4.5 m and the

slab extends sufficiently beyond the external beams to provide full development length for the bottom transverse reinforcement;

(b) the ratio of the spacing of the supporting beams to the thickness of the slab does not exceed 20;(c) the minimum slab thickness of sound concrete is at least 150 mm (with the minimum slab thickness

used for slabs of variable thickness);(d) all cross-frames or diaphragms extend throughout the cross-section of the bridge between external

girders and the maximum spacing of such cross-frames or diaphragms is in accordance with Clause 8.18.5; and

(e) edge stiffening is in accordance with Clause 8.18.6.

14.14.1.3.3 Simplified methodIf all of the conditions of Clause 14.14.1.3.2 are satisfied, the value of the factored resistance, Rr , shall be calculated as follows:

Rr = md Rn

where

md = 0.5

The values of Rn for both composite and non-composite concrete deck slabs shall be calculated as follows:

Rn = Rd Fq Fc

where Rd is taken from Figure 14.4 or 14.5, as applicable, for the deck thickness, d, and the deck span being considered; Fq is a correction factor based on q, where q = 50 (As/bd + Ast /bdt ); and Fc is a correction factor based on fc’.

The values of Fq and Fc shall be taken from Figure 14.4 or 14.5, as applicable, or obtained from those figures by linear interpolation.

For deck thicknesses other than those shown in Figures 14.4 and 14.5, the value of Rn shall be obtained by linear interpolation.

(Replaces p. 666, November 2006)666

Single user license only. S

torage, distribution or use on network prohibited

Page 76: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Figure 14.7Spacing requirements for minimum reinforcement

as a fraction of shear depth(See Clause 14.14.1.6.2.)

14.14.1.6.3 Proportioning of transverse reinforcement

14.14.1.6.3.1 GeneralFor the purpose of evaluation, Clause 14.14.1.6.3.2 shall apply in lieu of Clause 8.9.3.9.

14.14.1.6.3.2 Amount of transverse reinforcementProvided that the cross-section does not change abruptly within a length equal to the member depth, h, and the load is applied through the top face of the beam, the amount of transverse reinforcement, Av h/s, may be taken as the total amount calculated within the length h. This length shall be measured from the section of interest toward the support.

14.14.1.7 Wood

14.14.1.7.1 GeneralThe resistances for beam and stringer grade and post and timber grade wood members of Select Structural Grade and Grade 1 quality shall be determined in accordance with Clauses 14.14.1.7.2 and 14.14.1.7.3. All other wood resistances shall be determined in accordance with Section 9.

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4

Sp

acin

g as

a fr

actio

n of

dv

sr1

sr2

0.75

0.33

(Vf – Vp) /(fcbv f’c)dv

671(Replaces p. 671, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 77: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

14.14.1.7.2 ShearThe shear resistance in wood shall be taken from Clause 9.7, with fv u taken from Table 14.14 and the size effect factor, ksv , taken as follows:

kd a dsv =

+( )≤75 1

1 2 / 2.5

where

d = member depth

For members older than five years, a shall be the distance measured from the centreline of the support to the tip of the end split. Where the split does not extend past the centreline of the support into the span, a shall be taken as zero.

For members that are not older than five years, or where the end split length has not been measured, a shall be assumed to be 0.33d for Select Structural Grade and 0.75d for Grade 1.

14.14.1.7.3 Specified strengths and moduli of elasticityThe specified strengths and moduli of elasticity shall be obtained from Table 14.14.

Table 14.14Specified strengths and moduli of elasticity for beam and stringer

grades and post and timber grades, MPa(See Clauses 14.14.1.7.2 and 14.14.1.7.3.)

14.14.1.8 Shear in steel plate girders with intermediate transverse stiffenersClauses 10.10.5 and 10.10.6 shall be used to calculate the shear resistance of steel plate girders with intermediate transverse stiffener plates on one side of the web if the width-to-thickness ratio of the plate

does not exceed 400/ Fy .

14.14.2 Resistance adjustment factorFor all components that have no visible sign of defect or deterioration, the factored resistance, as calculated in accordance with Clause 14.14.1, shall be multiplied by the appropriate resistance adjustment factor, U, specified in Table 14.15. Where no value for U is specified in Table 14.15 and in lieu of better information, a value of U = 1.0 may be used.

Species Combination Grade

Bending at extreme fibre, ƒbu

Longitudinal shear, ƒvu

Compressionparallel to grain, ƒpu

Compression perpendicular to grain, ƒqu

Tensionparallelto grain, ƒtu

Modulus of elasticity

E50 E05

Douglas fir–Larch

SSNo. 1

24.020.0

1.11.1

16.510.0

4.74.7

13.09.0

11 0009 500

7 5006 500

Hem-Fir SSNo. 1

20.018.0

0.80.8

14.510.5

3.13.1

13.09.0

11 00010 500

7 5007 000

Spruce-Pine-Fir

SSNo. 1

18.513.0

1.01.0

14.510.5

3.63.6

13.09.0

10 0009 000

7 0006 000

Northern species

SSNo. 1

13.010.8

0.80.8

10.07.0

2.32.3

10.07.0

7 0006 000

5 0004 000

Note: See Clause 9.3 for the symbols used in this Table.

(Replaces p. 672, November 2006)672

Single user license only. S

torage, distribution or use on network prohibited

Page 78: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

14.17 Bridge posting

14.17.1 GeneralThe calculations for the live load capacity factors for establishing posting limits shall be carried out in accordance with Clause 14.15 or 14.16. In certain cases, a single posting load, based on engineering judgment and experience, may be used, subject to Approval. Posting methods other than those specified in Clause 14.17, may be used, subject to Approval.

Subject to Approval, a concrete bridge with multiple load paths need not be posted if it has been carrying normal traffic without signs of excessive material cracking, deformation, or degradation. Such a bridge shall be inspected at intervals recommended by the evaluator.

14.17.2 Calculation of posting loadsWhen Evaluation Levels 1, 2, and 3 are used as a basis for posting, the smallest value of F from Clause 14.15 or 14.16 shall be calculated and applied as follows:(a) when F 1.0 for Evaluation Level 1, posting shall not be required;(b) when 1.0 > F 0.3 for Evaluation Level 1, triple posting shall be required, with the posting loads for

each evaluation level being obtained from Figure 14.8 for the appropriate value of F for each evaluation level;

(c) when F < 0.3 for Evaluation Level 1 and F 0.3 for Evaluation Level 3, single posting corresponding to Evaluation Level 3 shall be required, with the posting load being obtained from Figure 14.8 for Evaluation Level 3 only; and

(d) when F < 0.3 for Evaluation Level 3, consideration shall be given to closing the bridge.

677(Replaces p. 677, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 79: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Posting factor, P

Live

load

cap

acity

fact

or, F

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.30 0.02 0.04 0.06 0.08 0.10

0.011 0.02 0.028

Eval

uatio

n Le

vel 3

Eval

uatio

n Le

vel 2

Eval

uatio

n Le

vel 1

0.100.0720.04

S6S1-10 © Canadian Standards Association

May 2010

Figure 14.8Posting loads for gross vehicle weight

(See Clauses 14.17.2 and 14.17.3.1.)

14.17.3 Posting signs

14.17.3.1 GeneralThe posted weight limit(s) in tonnes shall be PW, where P is the posting factor shown in Figure 14.8 and W is in kilonewtons and as specified in Clause 14.9.1.2. For ONT loads specified for use in Ontario, W equals 625 kN.

14.17.3.2 Single posting signs for vehiclesPosting signs shall be in accordance with the regulations set by the Regulatory Authority. Posting shall show the gross vehicle weight to the nearest tonne.

(Replaces p. 678, November 2006)678

Single user license only. S

torage, distribution or use on network prohibited

Page 80: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

15.6.1.4.2 Restricted highway live loadsFor bridges to be rehabilitated and posted for restricted highway live loads, the dynamic load allowance specified in Section 3 shall be multiplied by the dynamic load allowance modification factor specified in Clause 14.9.3.

15.6.1.5 Thermal, shrinkage, and creep effectsProvision shall be made in the rehabilitation design for expansion and contraction due to temperature, shrinkage, and creep. Load effects induced by any restraints on these movements shall be included in the rehabilitation design.

15.6.1.6 Wind loadsWind loads shall be as specified in Section 3.

15.6.1.7 Collision loadsCollision loads in accordance with Section 3 shall be considered unless effective measures are taken to protect the bridge and its components against these loads.

15.6.1.8 Settlement and permanent deformationsLoad effects resulting from settlement and permanent deformations in the bridge or its components shall be included in the rehabilitation design.

15.6.1.9 Seismic loadsSeismic loads shall be considered in accordance with Section 4.

15.6.1.10 Stream flow and ice pressure loadsLoad effects resulting from stream flow and ice pressure shall be considered in accordance with Section 3.

15.6.1.11 Component deteriorationLoad effects resulting from redistribution of loads due to deterioration of components shall be included in the rehabilitation design.

15.6.1.12 Loads induced by the rehabilitationLoads induced in the bridge or its components during rehabilitation construction and any changes in the bridge or its components resulting from the rehabilitation shall be included in the rehabilitation design.

15.6.2 Load factors and load combinations

15.6.2.1 GeneralUnless otherwise specified by the Regulatory Authority, all load factors and load combinations shall be in accordance with Section 3.

15.6.2.2 Minimum rehabilitation load factorsIf the purpose of the rehabilitation is to allow passage of a permit vehicle (see Clause 14.9.2), the load factors shall be in accordance with Section 14. The reliability index, , for all rehabilitated members shall be selected using Inspection Level INSP1.

If specified by the Regulatory Authority, load factors from Section 14 may be used for a bridge rehabilitation intended to carry normal traffic, but shall be selected using Inspection Level INSP1.

15.6.2.3 Total factored load effectFor each load combination, every load that is to be included shall be multiplied by the specified load factor and then added to the other loads to obtain the total factored load effect.

691(Replaces p. 691, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 81: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

15.6.2.4 Overall minimum load factorExcept for PB or PC vehicles, the total factored load effect for ULS Combination 1 (see Table 3.1) shall not be less than 1.25 times the sum of the unfactored load effects. This requirement may be waived if the member provides a live load capacity factor, F, greater than or equal to 1.0 in accordance with the mean load method specified in Clause 14.15.2.3. For PC vehicles, the total factored load effect for ULS Combination 1 shall not be less than 1.15 times the sum of the unfactored load effects.

15.7 AnalysisStructural analysis shall be performed in accordance with this Section and the other applicable Sections of this Code.

The effects of member connections, connection continuity, support restraints, the contribution of the secondary components, and the interaction between the new and existing components of the bridge shall be considered in the analysis.

Structural analysis shall consider the extent of member deterioration and existing locked-in stresses due to system behaviour, their effect on the strength and stiffness characteristics of the member, and their effect on the strength of the structural system.

15.8 Resistance

15.8.1 Existing members

15.8.1.1 GeneralThe factored resistances of existing members, including existing members strengthened with new material, shall be determined in accordance with Clauses 14.14.1 and 14.14.2.

The factored resistances of existing members shall be reduced to account for any member defects or deterioration in accordance with Clause 14.14.3.

In addition, the effects on member resistance and ductility of different stress levels in the new and existing portions of hybrid members shall be considered.

15.8.1.2 Strengthening using fibre-reinforced polymerIn addition to satisfying the requirements of Clause 15.8.1.1, members strengthened using fibre-reinforced polymer shall satisfy the durability requirements of Clause 16.4.

The design of concrete or wood members strengthened with fibre-reinforced polymer shall also satisfy the requirements of Clause 16.11 or 16.12, respectively.

15.8.2 New membersThe factored resistances of new members shall be determined in accordance with Sections 5 to 13 and 16.

(Replaces p. 692, November 2006)692

Single user license only. S

torage, distribution or use on network prohibited

Page 82: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Open time — the maximum time for joining together adherents after adhesive has been applied in order to avoid surface alteration of the adhesive.

Plate — an FRP component whose thickness is significantly less than its other dimensions.

Pot life — the time one can work with primer, putty, and/or adhesive after mixing resin and a hardener before the primer, putty, and/or adhesive starts to harden in the mixture vessel.

Primary reinforcement — reinforcement provided mainly for strength.

Rope — an assembly of bundled continuous fibres.

Secondary reinforcement — reinforcement provided mainly for control of cracking.

Sheath — a protective encasement for a tendon or rope.

Sheet — a flexible component comprising fibres.

Shelf life — the length of time a material can be stored under specified environmental conditions and still continue to meet all applicable specifications for use.

Slab — a concrete slab that transfers load directly to the substructure.

Strand — a linear component that constitutes all or part of a tendon.

Strap — a linear component of steel or FRP that provides transverse restraint externally in a deck slab.

Stressed log bridge — a bridge deck made with logs that are trimmed to obtain two parallel faces and that are post-tensioned transversely.

Stressed wood deck — a stress-laminated wood deck or stressed log bridge.

Stress-laminated wood deck — a laminated wood deck that is post-tensioned perpendicular to the deck laminates.

Supporting beam — a stringer, floor beam, or girder.

Tendon — an FRP or high-strength steel element that imparts prestress to a structural component.

Thermoplastic matrix — a polymer capable of being repeatedly softened by an increase in temperature and hardened by a decrease in temperature.

Thermoset matrix — a polymer that changes into a substantially infusible and insoluble material when cured by heat, chemicals, or both.

Wet lay-up — a method of making an FRP-laminated product that involves applying a resin system as a liquid when the fabric is put in place.

16.3 Abbreviations and symbols

16.3.1 AbbreviationsThe following abbreviations apply in this Section:

AFRP — aramid-fibre-reinforced polymer

CFRP — carbon-fibre-reinforced polymer

FLS — fatigue limit state

FRC — fibre-reinforced concrete

697(Replaces p. 697, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 83: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

FRP — fibre-reinforced polymer

GFRP — glass-fibre-reinforced polymer

NSMR — near-surface-mounted reinforcement

SLS — serviceability limit state

ULS — ultimate limit state

16.3.2 SymbolsThe following symbols apply in this Section:

A = area of cross-section of a strap or bar, mm2

AFRP = area of cross-section of an FRP bar, plate, sheet, or tendon, mm2

Af = area of cross-section of deck slab formwork along a section parallel to the beams, per unit length of the formwork, mm2/mm

Ap = area of steel tendons in the tension zone, mm2

As = area of cross-section of steel or FRP reinforcing bars used in edge stiffening of deck slabs, as shown in Figures 16.2 and 16.5, mm2

Av = area of transverse shear reinforcement perpendicular to the axis of a member, mm2

Av,min = minimum required area of transverse shear reinforcement perpendicular to the axis of a member, mm2

b = smallest log diameter, mm; height of the flat face of a trimmed log, as shown in Figure 16.10, mm; width of a rectangular section, mm

bv = effective width of web within depth dlong , mm (see Clause 8.9.1.6)

bw = width of web of a T-section, mm

Dg = diameter of a circular column or equivalent diameter of a rectangular column, mm (see Clause 16.11.2.5.6)

d = effective depth of a reinforced concrete component, being the distance from the compression face to the centroid of the tensile reinforcement, mm

dFRP = effective shear depth for FRP, mm, calculated in the same manner as dlong for longitudinal reinforcement

db = equivalent diameter of a bar, tendon, or strand in a multiple-strand tendon, mm

dc = distance from the centroid of the tension reinforcement to the extreme tension surface of concrete, mm

dcs = smaller of the distance from the closest concrete surface to the centre of the bar being developed, or two-thirds the centre-to-centre spacing of the bars being developed, mm

dlong = effective shear depth for longitudinal reinforcement, mm

ds = diameter of an FRP stirrup in Clause 16.8.7(c), mm; distance from the top of the slab to the centroid of the bottom transverse FRP bars in Clause 16.8.8.1(b), mm

E = modulus of elasticity, MPa

EFRP = mean modulus of elasticity of FRP bars, plates, sheets, and tendons, MPa

Ep = modulus of elasticity of steel tendons, MPa

Es = modulus of elasticity of steel, MPa

EvFRP = modulus of elasticity of the FRP stirrups, MPa (see Clause 16.8.7)

EI = flexural rigidity, N•mm2

F = live load capacity factor (see Clause 14.15.2)

FSLS = dimensionless factor (see Clause 16.8.3)

Fs = factor in Clauses 16.7.2(c) and 16.7.3(g), MPa

Ft = dimensionless factor (see Clause 16.5.2)

(Replaces p. 698, November 2006)698

Single user license only. S

torage, distribution or use on network prohibited

Page 84: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

fFRP = stress in the tension FRP reinforcement, MPa

fFRPbend = specified tensile strength of the straight portion of an FRP bent stirrup, MPa

fFRPu = specified tensile strength of an FRP bar, grid, plate, sheet, tendon, or aramid rope, MPa

fbu = specified bending strength of wood, MPa

fc’ = specified compressive strength of concrete, MPa

fcc’ = compressive strength of confined concrete, MPa

fcr = cracking strength of concrete, MPa

fFRP = confinement pressure due to FRP strengthening at the ULS, MPa

fpo = stress in tendons when the stress in the surrounding concrete is zero, MPa

fps = maximum permissible stress in a tendon at the ULS, MPa

fvu = specified shear strength of timber (see Section 9)

fy = specified yield strength of steel reinforcing bars, MPa

h = depth of a timber beam, mm

h1 = distance from the centroid of tension reinforcement to the neutral axis, mm

h2 = distance from the extreme flexural tension surface to the neutral axis, mm

J = overall performance factor for a concrete beam or slab with a rectangular section or a T-section

KbFRP = non-dimensional factor (see Clauses 16.12.2.1 and 16.12.2.2)

Ktr = transverse reinforcement index, mm (see Clause 8.15.2.2)

KvFRP = non-dimensional factor (see Clauses 16.12.3.1 and 16.12.3.2)

kb = coefficient depending on bond between FRP and concrete

k1 = bar location factor (see Clause 8.15.2.4); concrete strength factor (see Clause 16.11.3.2)

k2 = non-dimensional factor (see Clause 16.11.3.2)

k4 = bar surface factor

Le = effective anchorage length of an FRP sheet, mm (see Clause 16.11.3.2)

Lu = unsupported length of a transverse edge beam, mm

a = minimum required anchorage length for externally bonded FRP beyond the point where no strengthening is required, mm

d = development length of FRP bars and tendons, mm

Mc = moment at a section corresponding to a maximum compressive concrete strain of 0.001, N•mm

Mcr = cracking moment, N•mm

Mf = factored moment at a section, N•mm

Mr = factored flexural resistance of a section, N•mm

Mult = ultimate moment capacity of a section, N•mm

Nf = factored axial load normal to the cross-section occurring simultaneously with Vf , including the effects of tension due to creep and shrinkage, N

n = number of test specimens

Po = factored axial resistance of a section in pure compression, N

Pr = factored axial resistance of a section in compression with minimum eccentricity, N

Ri = post-cracking residual strength index

r = radius of curvature of the bend of an FRP stirrup, mm; radius of curvature of the saddle for a deflected straight tendon, mm

S = centre-to-centre spacing of beams supporting a deck slab, mm

S = spacing of straps, mm

699(Replaces p. 699, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 85: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

s = spacing of shear or tensile reinforcement, mmsFRP = spacing of externally bonded FRP bands on concrete for shear strengthening, measured

along the axis of the member, mmTgw = wet glass transition temperature, i.e., the glass transition temperature after moisture uptake

by the polymer, °Ct = thickness of an externally restrained deck slab, including that of the stay-in-place formwork, if

present, mmtFRP = total thickness of externally bonded FRP plates or sheets, mmtc = thickness of cast-in-place concrete in a deck slab cast on a stay-in-place formwork, if

present, mmts = projection of a shear connector or other shear-connecting device into a deck slab, as shown

in Figure 16.1 for shear connectors, mmV = coefficient of variation of the strength of FRP components, being the ratio of the standard

deviation to the meanVFRP = factored shear resistance provided by the FRP shear reinforcement, NVc = factored shear resistance provided by tensile forces in concrete, NVf = factored shear force at a section, NVp = component in the direction of the applied shear of all of the effective prestressing forces

crossing the critical section, factored by p (see Clause 8.4.6), to be taken as positive if resisting the applied shear, N

Vr = factored shear resistance, NVs = factored shear resistance provided by the steel shear reinforcement, NVst = factored shear resistance provided by the shear reinforcement, N

wFRP = width of an FRP sheet measured perpendicular to the direction of the main fibres, mmwcr = crack width at the tensile face of the flexural component, mm = angle of inclination of internal or external transverse reinforcement to the longitudinal axis of

the member, degrees = factor used to account for shear resistance of cracked concreteFRPe = effective strain in FRP (see Clause 16.11.3.2)FRPu = ultimate strain in FRPv = strain in an FRP stirrupx = longitudinal strain calculated in accordance with Clause 16.8.7 = angle of inclination of the principal diagonal compressive stress to the longitudinal axis of the

member, degreesV = bond reduction factor (see Clause 16.11.3.2)s = ratio of the cross-sectional area of the longitudinal FRP reinforcement to the effective

cross-sectional area of the beamvFRP = ratio of the total cross-sectional area of the legs of an FRP stirrup to the product of the width

of the beam and the spacing of the stirrupsN = stress in concrete due to axial loads, MPa v = stress calculated in accordance with Clause 16.8.7FRP = resistance factor for FRP components (see Clause 16.5.3)c = resistance factor for concrete (see Clause 8.4.6)

c = curvature at a section when the moment is Mc, mm–1

ult = curvature at a section when the moment is Mult, mm–1

(Replaces p. 700, November 2006)700

Single user license only. S

torage, distribution or use on network prohibited

Page 86: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

16.5.3 Resistance factorThe resistance factor, FRP , for pultruded FRP and aramid fibre rope shall be as specified in Table 16.2. For non-pultruded FRP made by wet lay-up, FRP shall be 0.75 times the corresponding value in Table 16.2. For non-pultruded FRP made in accordance with other factory-based controlled processes, FRP shall be 0.85 times the corresponding value in Table 16.2.

Table 16.2FRP for pultruded FRP and aramid fibre rope

(See Clause 16.5.3.)

16.6 Fibre-reinforced concrete

16.6.1 GeneralRandomly distributed fibre reinforcement shall be permitted in deck slabs, barrier walls, and surfacing of stressed log bridges for the control of cracks that develop in concrete during its early life. Its use in other applications shall require Approval.

16.6.2 Fibre volume fractionThe fibre volume fraction shall be such that the residual strength index, Ri , is at least that specified by Table 16.3 for the particular application, where Ri is calculated as

Ri = ARS/R

where ARS = mean value of the average residual strength determined using the ASTM C 1399 test on at least

five fibre-reinforced concrete beam specimens

R = mean value of the modulus of rupture determined by performing the ASTM C 78 test on at least five fibre reinforced concrete specimens

Application FRP

AFRP reinforcement in concrete and NSMR 0.65

AFRP in externally bonded applications 0.55

AFRP and aramid fibre rope tendons for concrete and timber components 0.60

CFRP reinforcement in concrete 0.80

CFRP in externally bonded applications and NSMR 0.80

CFRP tendons 0.80

GFRP reinforcement in concrete 0.55

GFRP in externally bonded applications and NSMR 0.70

GFRP tendons for concrete components 0.55

GFRP tendons for timber decks 0.70

703(Replaces p. 703, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 87: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

Table 16.3Minimum values of Ri for various applications

(See Clause 16.6.2.)

16.6.3 Fibre dispersion in concreteFibres shall be mixed uniformly in concrete. The Plans shall specify that before a given mix of FRC is used in the structure, the uniformity of dispersion of the fibres shall be confirmed visually.

As an additional measure, the possibility of non-uniform fibre dispersion shall be estimated by comparing the compressive strength of FRC with that of the corresponding plain concrete using 7-day compressive strength tests in accordance with CAN/CSA-A23.1. If the FRC mix has a mean compressive strength less than 90% of that of the corresponding plain concrete, engineering judgment shall be exercised to determine corrective measures.

16.7 Externally restrained deck slabs

16.7.1 GeneralAn externally restrained deck slab supported on parallel longitudinal beams that complies with Clause 16.7.2, 16.7.3, or 16.7.4 and satisfies the following conditions need not be analyzed except for negative transverse moments due to loads on the overhangs and barrier walls, and for negative longitudinal moments in continuous span bridges:(a) The deck slab is composite, with parallel supporting beams in the positive moment regions of the

beams.(b) The spacing of the supporting beams, S, does not exceed 3000 mm.(c) The total thickness of the deck slab, including that of the stay-in-place formwork, if present, t, is at

least 175 mm and at least S/15.(d) The supporting beams are connected with transverse diaphragms or cross-frames at a spacing of not

more than 8000 mm.(e) The deck slab is confined transversely by straps or a stay-in-place formwork in accordance with the

applicable provisions of Clause 16.7.2, 16.7.3, or 16.7.4.(f) When the deck slab is confined by straps, the distance between the top of the straps and the bottom

of the slab is between 25 and 125 mm, as shown in Figure 16.1.(g) The projection of the shear connectors in the deck slab, ts , is at least 75 mm, as shown in Figure 16.1,

or additional reinforcement with at least the same shear capacity as that of the shear connectors is provided and the projection of the additional reinforcement into the slab is at least 75 mm.

(h) The cover distance between the tops of the shear-connecting devices and the top surface of the deck slab is at least 75 mm when the slab is not exposed to moisture containing de-icing chemicals; otherwise, this cover distance is at least 100 mm or the shear-connecting devices have an Approved coating.

Application Minimum value of Ri

Barrier wall with one mesh of bars 0.25

Barrier wall with two meshes of bars 0.0*

Deck slab with one crack-control mesh 0.25

Deck slab with two crack-control meshes 0.0*

Surfacing of stressed log bridges 0.30

*Fibres not needed.

(Replaces p. 704, November 2006)704

Single user license only. S

torage, distribution or use on network prohibited

Page 88: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

(i) The fibre volume fraction in the cast-in-place concrete is in accordance with Clause 16.6.2.(j) The deck slab contains appropriate tensile reinforcement for transverse negative moments resulting

from loads on deck slab overhangs and loads on railings or barrier walls.(k) The transverse edges of the deck slab are stiffened by composite edge beams with a minimum

flexural rigidity, EI, in the plane of the deck slab of 3.5Lu4 Nmm2, where Lu is the unsupported length

of the edge beam, or, for an unsupported length of edge beam less than 4250 mm, the details of the transverse edge beams are as shown in Figure 16.2, 16.3, 16.4, or 16.5.

(l) For continuous span bridges, the deck slab contains longitudinal negative moment reinforcement in at least those segments where the flexural tensile stresses in concrete for the SLS cases are larger than 0.6fcr, where fcr is calculated as follows:

(m) The spacing of the reinforcement bars shall not exceed 300 mm. The diameter of reinforcement bars shall not be less than 15 mm.

When the conditions specified in this Clause and the requirements specified in Clause 16.7.1, 16.7.2, or 16.7.3, as applicable, are not satisfied, the design of the externally restrained deck slab shall require Approval.

16.7.2 Full-depth cast-in-place deck slabsThe design of an externally restrained deck slab with full-depth cast-in-place construction shall meet the requirements of Clause 16.7.1 and the following requirements:(a) The top flanges of all adjacent supporting beams shall be connected by straps that are perpendicular

to the supporting beams and either connected directly to the tops of the flanges, as in the case of the welded steel straps shown in Figure 16.6, or connected indirectly, as in the case of the partially studded straps shown in Figure 16.7; alternatively, the transverse confining system shall comprise devices that have been proved through Approved full-scale laboratory testing.

(b) The spacing of straps, S , shall be not more than 1250 mm.(c) Each strap shall have a minimum cross-sectional area, A, in mm2, as follows:

where

Fs = 6.0 MPa for outer panels and 5.0 MPa for inner panels

E = modulus of elasticity of the strap material

In the case of FRP straps, the main fibres shall be in the direction perpendicular to the supporting beams.

(d) The direct or indirect connection of a strap to the supporting beams shall be designed to have a minimum shear strength in newtons of 200A.

(e) In a negative moment region of a supporting beam, where the beam is not made composite, shear-connecting devices shall be provided on the beam in the vicinity of the straps, and have a minimum total shear strength in newtons of 200A (as shown, e.g., in Figure 16.8). As shown in Figure 16.7, such shear-connecting devices shall be within 200 mm of the nearest strap.

(f) The deck slab shall have a crack-control orthogonal assembly of GFRP bars placed near the bottom of the slab, with the area of the cross-section of the GFRP bars in each direction being at least 0.0015t mm2/mm.

When steel straps are welded to steel girders in negative moment regions, the fatigue of the girder shall be considered.

When the conditions specified in Clause 16.7.1 and the requirements specified in this Clause are not satisfied, the design of the slab shall require Approval.

f fcr c= ′0 4.

705(Replaces p. 705, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 89: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

16.7.3 Cast-in-place deck slabs on stay-in-place formworkThe design of an externally restrained deck slab with cast-in-place construction on stay-in-place formwork shall meet the requirements of Clause 16.7.1 and the following requirements:

AF SEtfs=

2

(a) The design of the formwork shall take into account its anticipated handling and anticipated conditions during construction.

(b) The effective span of the formwork shall be taken as the distance between the edges of the supporting beams plus 150 mm.

(c) The deflection of the formwork during construction shall not exceed 1/240 of the effective span of the formwork.

(d) The ends of the formwork shall be supported on beams in such a manner that after placement of concrete topping a support length of at least 75 mm shall be provided under the lower portions of the formwork. Such support shall be within 25 mm of the closer edges of the supporting beams.

(e) The top flanges of all adjacent supporting beams shall be connected by external straps or the formwork itself.

(f) When the deck slab is confined by straps, the straps and their connections shall be designed to satisfy the requirements specified in Items (a) to (e) of Clause 16.7.2.

(g) When the deck slab is restrained by a formwork, the concept shall have been verified by tests on full-scale models. In addition, the minimum area of cross-section of the formwork, in mm2/mm, across a section parallel to the beams, Af , shall be calculated as follows:

where

Fs = 6.0 MPa for outer panels and 5.0 MPa for inner panels

E = modulus of elasticity of the material of the formwork in the direction perpendicular to the supporting beams

(h) When the deck slab is restrained by a formwork, the direct or indirect connection of the formwork to the supporting beams shall have been proved by full-scale tests to have a shear strength in N/mm of at least 200Af .

(i) When the formwork is of precast concrete construction, it shall contain a crack-control orthogonal assembly of GFRP bars placed at its mid-depth, with an area of cross-section of GFRP bars in each direction equal to 0.0015t mm2/mm.

(j) When it is of precast construction, the formwork panel shall have a maximum thickness of 0.5t.(k) When it is of precast construction, the upper surface of the formwork panel shall be clean, free of

laitance, and roughened to an amplitude of 2 mm at a spacing of nearly 15 mm.(l) The cast-in-place concrete shall have a crack-control orthogonal assembly of GFRP bars placed in the

middle of the cast-in-place slab, with the area of the cross-section of the GFRP bars in each direction being at least 0.0015tc mm2/mm.

When the conditions specified in Clause 16.7.1 and the requirements specified in this Clause are not satisfied, the design of the slab shall require Approval.

16.7.4 Full-depth precast concrete deck slabsThe design of an externally restrained deck slab with full-depth precast concrete construction shall require Approval.

(Replaces p. 706, November 2006)706

Single user license only. S

torage, distribution or use on network prohibited

Page 90: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

16.8 Concrete beams and slabs

16.8.1 GeneralExcept as specified in this Section, the resistance and deformations of concrete beams, slabs, and deck slabs reinforced with FRP tendons, bars, or grids, corresponding to the various limit states, shall be calculated in accordance with Section 8.

The resistance at ULS for beams and slabs with FRP bars or grids in multiple layers shall be calculated by taking account of the linear variation of strain through the depth of the member, ensuring that the stresses in the reinforcement are consistent with Clause 16.8.3.

The maximum compressive concrete strains in beams and slabs due to factored loads shall not exceed the limiting strain specified in Section 8.

Internally restrained deck slabs shall be designed in accordance with Clause 16.8.8.

16.8.2 Deformability and minimum reinforcement

16.8.2.1 Design for deformabilityFor concrete components reinforced with FRP bars or grids, the overall performance factor, J, shall be at least 4.0 for rectangular sections and 6.0 for T-sections, with J calculated as follows:

JM

Mult ult

c c=

yy

where

Mult = ultimate moment capacity of the section

ult = curvature at Mult

Mc = moment corresponding to a maximum compressive concrete strain in the section of 0.001

c = curvature at Mc

16.8.2.2 Minimum flexural resistanceThe factored resistance, Mr , shall be at least 50% greater than the cracking moment, Mcr, as specified in Clause 8.8.4.4. This requirement may be waived if the factored resistance, Mr, is at least 50% greater than the factored moment, Mf . If the ULS design of the section is governed by FRP rupture, Mr shall be greater than 1.5Mf .

The principles for calculating Mcr and Mr shall be consistent with those specified in Clause 8.8, except that stresses in FRP bars at different levels, if present, shall be calculated by assuming a linear distribution.

16.8.2.3 Crack-control reinforcementWhen the maximum tensile strain in FRP reinforcement under full service loads exceeds 0.0015, cross-sections of the component in maximum positive and negative moment regions shall be proportioned in such a way that the crack width does not exceed 0.5 mm for members subject to aggressive environments and 0.7 mm for other members, with the crack width calculated as follows:

wfE

hh

k d scrFRP

FRPb c= + ( )2 22

1

2 2/

The value of kb shall be determined experimentally, but in the absence of test data may be taken as 0.8 for sand-coated and 1.0 for deformed FRP bars. In calculating dc , the clear cover shall not be taken greater than 50 mm.

711(Replaces p. 711, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 91: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

16.8.3 Non-prestressed reinforcementThe maximum stress in FRP bars or grids under loads at SLS shall not be more than FSLS fFRPu , where FSLS is as follows:(a) for AFRP: 0.35;(b) for CFRP: 0.65; and(c) for GFRP: 0.25.

16.8.4 Development length for FRP bars and tendons

16.8.4.1 GeneralThe development length, d , for FRP bars in tension shall be calculated as follows:

wherefFRP = stress in the tension reinforcement at ULS

In addition, d shall not be taken as less than 250 mm.All of the variables in this equation shall be in accordance with Clause 8.15.2.2, except as follows:(a) The variable k4 is the bar surface factor, being the ratio of the bond strength of the FRP bar to that of

a steel deformed bar with the same cross-sectional area as the FRP bar, but not greater than 1.0. In the absence of experimental data, k4 shall be taken as 0.8.

(b) The variable EFRP is the modulus of elasticity of the FRP bar.(c) The term (dcs + Ktr EFRP /Es ) shall not be taken greater than 2.5db .(d) The bond strength of the FRP bar shall be determined by testing or taken to be the bond strength

specified by the manufacturer of the bar.

16.8.4.2 Splice length for FRP barsThe splice length for FRP bars in tension shall be 1.3d , where d is calculated in accordance with Clause 16.8.4.1. Spliced FRP bars shall not be separated by more than 150 mm.

16.8.5 Development length for FRP gridsFor FRP grids in which the intersecting orthogonal bars have been demonstrated to be fully anchored, the development length shall include at least two transverse bars of the grid lying perpendicular to the direction of the force under consideration.

16.8.6 Tendons

16.8.6.1 Supplementary reinforcementA structure incorporating concrete beams or slabs with FRP tendons shall contain supplementary reinforcement capable of sustaining the unfactored dead loads or have alternative load paths such that the failure of one beam or a portion of a slab will not lead to progressive collapse of the structure.

16.8.6.2 Stress limitations for tendonsFor straight tendons, the maximum stress at jacking and transfer shall not exceed the values specified in Table 16.4. For curved tendons, the maximum stresses at jacking and transfer shall be those specified in Table 16.4, reduced by an amount determined from tests.

FRP tendons shall be stressed to provide a minimum effective prestress of 75% of the stresses at transfer.The maximum SLS stresses after all prestress losses shall not exceed the FSLS values specified in

Clause 16.8.3.

(Replaces p. 712, November 2006)712

Single user license only. S

torage, distribution or use on network prohibited

Page 92: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

The maximum stress in the tendons under factored loads at ULS, fps , computed using a method based on strain compatibility, shall not exceed FRP fFRPu , where the resistance factor FRP is as specified in Clause 16.5.3.

Table 16.4Maximum permissible stresses in FRP tendons at

jacking and transfer for concrete beams and slabs for pretensioning and post-tensioning systems

(See Clauses 16.8.6.2 and 16.9.4.)

16.8.6.3 Capacity of anchorsWhen tested in an unbonded condition, anchors for post-tensioning tendons shall be capable of developing a tendon force at least 50% higher than the jacking force, but not more than 90% of the specified tensile strength of the tendons, without exceeding the anticipated set. After tensioning and seating, anchors shall sustain applied loads without slippage, distortion, or other changes that result in loss of prestress. The Plans shall specify that at least two anchors are to be tested to confirm this requirement.

16.8.6.4 End zones in pretensioned componentsThe end zones of pretensioned concrete components shall be reinforced against splitting unless it can be demonstrated that such reinforcement is unnecessary.

16.8.6.5 Protection of external tendonsExternal tendons comprising glass or aramid fibres shall be protected against ultraviolet rays by encasing them in protective sheaths; carbon fibre external tendons with ultraviolet-susceptible matrices shall also be similarly protected. Aramid fibre ropes shall be protected by sheaths and watertight anchors against the ingress of moisture.

16.8.7 Design for shearFor concrete beams reinforced with steel or FRP longitudinal reinforcement, and with steel or FRP stirrups, the factored shear resistance, Vr, shall be calculated as follows:

Vr = Vc + Vst + Vp

where

Vst = Vs or VFRP (in accordance with the type of stirrups used in the beam)

Clause 8.9.3 shall be used to calculate Vc , Vs , and Vp , except as follows:

V f b dc c cr v long= 2 5. bf

(a) Instead of calculating Vc in accordance with Clause 8.9.3.4, the following equation shall be used:

The effective shear depth, dlong , shall be calculated in accordance with Clause 8.9.1.5, and shall be calculated in accordance with Clause 8.9.3.7, after using the value of x in Clause 16.8.7(b).

Tendon At jacking At transfer

AFRP 0.40fFRPu 0.35fFRPu

CFRP 0.70fFRPu 0.65fFRPu

GFRP 0.30fFRPu 0.25fFRPu

713(Replaces p. 713, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 93: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

svs FRPbendr d f

=+( )0 05 0 3

1 5. / .

.

S6S1-10 © Canadian Standards Association

May 2010

(b) Instead of calculating x in accordance with Clause 8.9.3.8, one of the following equations shall be used:

(i)

(ii)

(c) For the factored shear resistance carried by FRP shear reinforcement, VFRP, the following equations shall be used:(i) for components with transverse reinforcement perpendicular to the longitudinal axis:

(ii) for components with transverse reinforcement inclined at an angle to the longitudinal axis:

For the equations in Items (i) and (ii), shall be obtained from Clause 8.9.3.7 for the general method; the coefficient FRP shall be as specified in Clause 16.5.3; and v shall be the smaller of the values obtained from the following two equations:

= EvFRPv

where

v = 0.004

(d) The minimum amount of shear reinforcement, Av,min , shall be calculated as follows:

Av,min =

where v is as specified in Item (c).

16.8.8 Internally restrained cast-in-place deck slabs

16.8.8.1 Design by empirical methodThe requirements of Clause 8.18 pertaining to cast-in-place deck slabs shall apply to cast-in-place deck slabs with FRP bars or grids, except that when the deck slab is designed using the empirical method of Clause 8.18.4, the following requirements shall be met in lieu of those specified in Items (a) and (c) of Clause 8.18.4.2:(a) the deck slab shall contain two orthogonal assemblies of FRP bars, with the clear distance between

the top and bottom transverse bars being at least 55 mm. The diameter of reinforcement bars shall not be less than 15 mm;

(b) for the transverse FRP bars in the bottom assembly, the minimum area of cross-section in mm2/mm shall be 500ds/EFRP ; and

(c) the longitudinal bars in the bottom assembly and the transverse and longitudinal bars in the top assembly shall be of GFRP with a minimum s of 0.0035.

ex

f

longf p f p po

s s p p

Md

V V N A f

E A E A=

+ − + − ( )+( ) ≤0 5

20 003

.

.

ex

f

longf p f FRP po

s s FRP FRP

Md

V V N A f

E A E A=

+ − + − ( )+( )

≤0 5

20 003

.

.

VA d

sFRPFRP v v long=

f s qcot

VA d

sFRPFRP v v long=

+f s q a a(cot cot ) sin

0 06. ′fb s

cw

vs

(Replaces p. 714, November 2006)714

Single user license only. S

torage, distribution or use on network prohibited

Page 94: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Consistent with the requirements of Clause 8.18.1, the requirements of Clause 16.8.2.3 shall be waived for decks designed using the empirical method.

The edge-stiffening details shall be as shown in Figures 16.2 to 16.5.

16.8.8.2 Design for flexureFor cast-in-place deck slabs with FRP bars or tendons designed for flexure, the requirements of Clauses 16.8.2 to 16.8.6 shall apply. In addition, the requirements of Clause 8.18.5 shall be satisfied for diaphragms.

The distribution reinforcement shall be designed in accordance with Clause 8.18.7. In addition, the spacing of the reinforcement in each direction shall not exceed 300 mm. The diameter of reinforcement bars shall not be less than 15 mm.

16.9 Stressed wood decks

16.9.1 GeneralClauses 16.9.2 to 16.9.6 shall apply to stress-laminated wood decks and stressed log bridges that are post-tensioned with FRP or fibre rope tendons.

16.9.2 Post-tensioning materials

16.9.2.1 TendonsGFRP, AFRP, and aramid ropes shall be permitted as tendons in stressed wood decks. The design of stressed laminated wood decks shall comply with Section 9 (with the exception of Clause 9.23.3.4) and Clauses 16.9.2.2 to 16.9.6.

16.9.2.2 AnchorsAnchors shall be capable of developing a tendon force at least 50% higher than the jacking force. The Plans shall specify that at least two anchors are to be tested to confirm this requirement.

16.9.2.3 Stress limitationsAt initial stressing, the stresses shall not exceed 0.35fFRPu for GFRP tendons or 0.40fFRPu for AFRP and aramid rope tendons.

16.9.3 Post-tensioning systemFor stressed log bridges, the post-tensioning system shall be external or internal (the external system is shown in Figure 16.9). For stress-laminated wood decks, the post-tensioning system shall be as shown in Figure 9.5 or 9.6, except that the tendons shall comprise GFRP, AFRP, or aramid ropes. When lower tendons in decks with external post-tensioning are exposed to damage from flowing debris, they shall be suitably protected.

715(Replaces p. 715, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 95: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Anchor

Steel channel bulkhead

Anchorage plate

5 mm (minimum)

Safety nut

Wood bearing block

Anchorage nut

Fibre tendon withprotective tubing

S6S1-10 © Canadian Standards Association

May 2010

Figure 16.9Post-tensioning system for stressed log bridges

(See Clause 16.9.3.)

16.9.4 Stressing procedureThe initial post-tensioning forces in the tendons shall be such as to bring the average interface pressure between wood laminates or logs to approximately 0.8 MPa, regardless of the species concerned. These forces shall be reduced 12 to 24 h after initial post-tensioning to establish an average interface pressure of 0.35 to 0.44 MPa, at which level the stresses in the tendons shall not exceed the relevant values specified in Table 16.4 for post-tensioning at transfer.

16.9.5 Design of bulkheadsStressed wood decks shall incorporate steel distribution bulkheads, as specified in Clause 9.23.4, except that the factored bearing resistance, calculated in accordance with Clause 9.23.4.2, shall be for the reduced post-tensioning forces specified in Clause 16.9.4.

16.9.6 Stressed log bridges

16.9.6.1 GeneralA stressed log bridge shall be constructed of logs(a) that are

(i) new; or (ii) used but structurally sound; and

(b) whose exposed surfaces have been suitably treated in accordance with Section 9.

16.9.6.2 Log dimensionsThe logs in a stressed log bridge shall meet the following requirements:(a) the ratio of the largest to the smallest diameter of a log shall be not more than 1.10;(b) the out-of-straightness of a log shall be not more than 0.003 times its length;(c) the end faces of a log shall be perpendicular to its axis to within an angular tolerance of 5°; and(d) the logs shall be trimmed longitudinally so as to provide, at any transverse cross-section, two

opposed faces that are parallel within an accuracy of 2°.

(Replaces p. 716, November 2006)716

Single user license only. S

torage, distribution or use on network prohibited

Page 96: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

16.9.6.3 Splicing at butt jointsAs shown in Figure 16.10, all butt joints shall be spliced by hot-dipped galvanized steel nail-plates with a minimum thickness of 1.5 mm. The nail-plates shall be installed by using a hydraulic jack or other Approved means to apply uniform pressure.

Height b

2b (minimum)

Galvanized nail-plate1.5 mm (minimum) thick

0.7b(min.)

Figure 16.10Spliced butt joint for logs

(See Clause 16.9.6.3.)

16.9.6.4 Frequency of butt jointsThe butt joints shall be staggered in such a way that within any band with a width of 1 m measured along the logs, a butt joint shall not occur in more than one out of four adjacent logs on each side of the log with a butt joint.

16.9.6.5 Holes in logs for an internal systemThe diameter of the holes drilled in the logs for an internal post-tensioning system shall be less than or equal to 20% of the minimum diameter of the logs.

16.9.6.6 Support anchorageA stressed log bridge shall be secured to the substructure by steel bars in accordance with the requirements of Clause 9.23.5.5 for stress-laminated wood decks.

16.9.6.7 SurfacingThe top of a stressed log bridge shall be surfaced by hot-mix asphalt or FRC incorporating low modulus polymer fibres. A fibre-reinforced concrete surfacing may be assumed to be acting compositely with the logs if the smallest thickness of concrete is not more than 50 mm.

16.9.6.8 Flexural resistance and stiffnessThe factored flexural resistance, Mr, of a stressed log bridge shall be calculated in accordance with Clause 9.6.1, except that the value of fbu shall be obtained from Table 9.17, which shall also be used for obtaining the modulus of elasticity of the logs.

717(Replaces p. 717, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 97: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

16.10 Barrier wallsA barrier wall that has the details shown in Figure 16.11 and satisfies the following conditions shall be deemed to have met the Performance Level 3 requirements of Section 12:(a) on the traffic side, the wall has a GFRP grid or an orthogonal assembly of GFRP bars providing a

factored strength of 330 N per millimetre length of the wall in the vertical direction and 240 N per millimetre length of the wall in the horizontal direction;

(b) the spacing of the bars in the GFRP grid or orthogonal assembly on the traffic side is not more than 300 mm;

(c) the wall is reinforced with(i) one planar GFRP grid or an orthogonal assembly of GFRP bars near the surface, as shown in

Figure 16.11, and FRC is used in accordance with Clause 16.6; or(ii) two layers of planar GFRP grid or two orthogonal assemblies of GFRP bars (in which case FRC is

not needed);(d) if a planar GFRP grid or an orthogonal assembly of GFRP bars is provided away from the traffic side, it

comprises bars of a diameter of at least 15 mm, at a spacing of 300 mm in the horizontal and vertical directions;

(e) if only one planar GFRP grid or orthogonal assembly of GFRP bars is used, the wall is provided at mid-thickness near its top with two 19 mm diameter steel bars or two 15 mm diameter GFRP bars, as shown in Figure 16.11;

(f) the wall is anchored to the slab by double-headed steel bars 19 mm in diameter and 500 mm long, or by bent GFRP bars whose performance has been established by Approved full-scale tests, at a spacing of 300 mm;

(g) the spacing of the bars and anchors is reduced by half for the following lengths of the wall:(i) 1.2 m on each side of a joint in the wall;(ii) 1.2 m on each side of a luminaire embedded in the wall; and(iii) 1.2 m from the free vertical edges of the wall; and

(h) the cover to GFRP bars (if any) meets the requirements of Clause 16.4.4 and the cover to double-headed bars (if any) meets the requirements of Clause 8.11.2.2.

Barrier walls for Performance Levels 1, 2, and 3 with details other than those shown in Figure 16.11 may be used if their performance has been established by Approved full-scale tests.

(Replaces p. 718, November 2006)718

Single user license only. S

torage, distribution or use on network prohibited

Page 98: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

16.11.2.4 Flexural components

16.11.2.4.1 Failure modesFor a section strengthened with FRP systems, the following flexural failure modes shall be investigated at ULS:(a) crushing of the concrete in compression before rupture of the FRP or yielding of the reinforcing steel;(b) yielding of the steel followed by concrete crushing before rupture of the FRP in tension;(c) yielding of the steel followed by rupture of the FRP in tension;(d) in the case of members with internal prestressing, additional failure modes controlled by the rupture

of the prestressing tendons; and(e) peeling failure or anchorage failure of the FRP system at the cut-off point.

16.11.2.4.2 Flexural resistance to sustained and fatigue loadsAt SLS and/or FLS, stresses shall be calculated based on elastic analysis. The effect of the FRP system on the serviceability may be assessed using transformed section analysis. The initial stresses and strains related to unfactored dead loads in a beam before strengthening shall be considered.

In addition to satisfying the requirements of Clause 8.5.2 for SLS and Clause 8.5.3 for FLS, the stress level in the FRP system due to all dead loads after strengthening and SLS live loads shall not exceed FSLS fFRPu , where the value of FSLS is obtained from Clause 16.8.3.

16.11.2.4.3 Factored flexural resistanceThe factored flexural resistance shall be calculated in accordance with Clause 16.11.2.3.

16.11.2.4.4 Anchorage lengths for flexureFor externally-bonded FRP strengthening systems, the anchorage length beyond the point where no strengthening is required shall not be less than a , calculated as follows:

�a FRP FRPE t= 0 5.

In addition, the anchorage length shall be at least 300 mm or the FRP shall be suitably anchored.For NSMR, the anchorage length, d , beyond the point where no strengthening is required shall be

calculated in accordance with Clause 16.8.4.1.

16.11.2.5 Compression components

16.11.2.5.1 GeneralFor FRP-strengthened columns subjected to combined flexure and axial compression, the factored resistance shall be calculated in accordance with Clause 16.11.2.3.

16.11.2.5.2 Slenderness effectsThe slenderness effects shall be accounted for in accordance with Clauses 8.8.5.2 and 8.8.5.3.

16.11.2.5.3 Maximum factored axial resistanceFor columns with FRP systems bonded to the external perimeter that meet the requirements of Clause 16.11.2.3, the factored axial resistance, Pr, shall be less than or equal to 0.80Po .

The confined concrete compressive strength determined in accordance with Clause 16.11.2.5.6 may be used to evaluate Po .

16.11.2.5.4 Biaxial loadingAn analysis based on stress and strain compatibility for a loading condition of compression and biaxial bending shall be used to design the FRP strengthening system.

721(Replaces p. 721, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 99: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

16.11.2.5.5 Transverse reinforcementIf the existing steel transverse reinforcement does not meet the requirements of Clause 8.14.4, FRP transverse reinforcement shall be provided in accordance with Clause 16.11.3.

16.11.2.5.6 Axial load capacity enhancementThe compressive strength of the confined concrete, fc‘c , shall be calculated as follows:

fc‘c = fc‘ + 2fFRP

The confinement pressure due to FRP strengthening at the ULS, fF RP , shall be calculated as follows:

ff tDFRP

FRP FRPu FRP

g� = 2f

For columns with circular cross-sections, Dg is the diameter of the column; for columns with rectangular cross-sections with aspect ratios less than or equal to 1.5 and a smaller cross-sectional dimension not greater than 800 mm, Dg is equal to the diagonal of the cross-section. For columns with other polygonal cross-sections, Dg is equal to the diameter of the circumscribed circle.

The confinement pressure at the ULS shall be designed to be between 0.1fc‘ and 0.33fc‘.

16.11.3 Shear rehabilitation with externally bonded FRP systems

16.11.3.1 GeneralClause 16.11.3 covers the proportioning of externally bonded FRP systems to increase the shear capacity of reinforced concrete beams and columns. The shear-strengthening scheme shall be of the type in which the fibres are oriented perpendicularly or at an angle to the member axis.

The shear reinforcement shall be anchored by suitable means in the compression zone in accordance with one of the following schemes:(a) the shear reinforcement shall be fully wrapped around the section, as shown in Figure 16.12;(b) the anchorage to the shear reinforcement near the compression flange shall be provided by

additional horizontal strips, as shown in Figure 16.12; and(c) the anchorage shall be provided in the compression zone, as shown in Figure 16.12.

However, an alternative anchorage scheme may be used if Approved.

(Replaces p. 722, November 2006)722

Single user license only. S

torage, distribution or use on network prohibited

Page 100: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Fully wrappedsection

Anchorage withhorizontal strips

Anchorage insidethe slab

© Canadian Standards AssociationSupplement No. 1 to CAN/CSA-S6-06,

Canadian Highway Bridge Design Code

May 2010

Figure 16.12Anchorage methods in the compression zone of externally

bonded FRP shear reinforcement(See Clause 16.11.3.1.)

16.11.3.2 Factored shear resistanceFor reinforced concrete members with rectangular sections or T-sections and FRP reinforcement anchored in the compression zone of the member, the factored shear resistance, Vr, shall be calculated as follows:

Vr = Vc + Vs + VFRP

Vc and Vs shall be calculated in accordance with Clause 8.9.3 and VFRP shall be calculated as follows:

VE A d

sFRPFRP FRP FRPe FRP FRP

FRP= +f e q a a(cot cot ) sin

where

FRPe = 0.004 0.75FRPu (for completely wrapped sections)

= VFRPu 0.004 (for other configurations)

For continuous U-shaped configurations of the FRP reinforcement, the bond-reduction coefficient, V, shall be calculated as follows:

keVe

FRPu

k k L= ≤1 2

119000 75.

where

k f

kd L

d

c

FRP e

FRP

12 3

2

27= ′( )

= −

/ /

723(Replaces p. 723, November 2006)

Single user license only. S

torage, distribution or use on network prohibited

Page 101: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

S6S1-10 © Canadian Standards Association

May 2010

For prestressed concrete components, Vr shall be the sum of Vc, Vs , Vp , and VFRP . The equations in this Clause shall be used to calculate VFRP. The general method of Clause 8.9.3 shall be used to calculate Vc, Vs , and Vp.

For components with non-rectangular or non-T cross-sections, a rigorous analysis or test shall guide the design.

16.11.3.3 Spacing and strengthening limitsThe spacing of FRP bands shall be not more than sFRP, calculated as follows:

s w dFRP FRP FRP= + ( )/4

The total factored shear resistance subsequent to FRP strengthening, Vr, shall not exceed the value given in Clause 8.9.3.3.

16.12 Rehabilitation of timber bridges

16.12.1 GeneralClause 16.12 applies to beams of timber and stringer grades strengthened with GFRP sheets or bars. The bars, if present, shall be near-surface mounted or embedded in holes in timber. The empirical methods specified in Clause 16.12 may be used to determine the strength of timber beams strengthened with GFRP sheets or bars for flexure, shear, or both.

Although the requirements of Clause 16.12 are intended for GFRP bars and sheets, AFRP and CFRP bars and sheets may be used in place of GFRP bars and sheets. If the strength for either flexure or shear needs to be more than is provided by the empirical methods of Clause 16.12, experimental evidence shall be used to determine the amount of FRP reinforcement.

The procedures for handling, storage, and protection of FRP sheets and bars shall be the same as those specified in Clause 16.4.8.

The Plans shall provide details and specifications relevant to the following and as specified in Annexes A16.1 and A16.2:(a) identification of the FRP strengthening systems and protective coatings;(b) surface preparation;(c) shipping, storage, and handling of the FRP strengthening systems;(d) installation of the FRP strengthening systems, including

(i) spacing and positioning of the components;(ii) locations of overlaps and multiple plies;(iii) installation procedures; and(iv) constraints for climatic conditions;

(e) the curing conditions of the strengthening systems;(f) the quality control of the strengthening systems, as specified in Annex A16.2;(g) staff qualifications;(h) material inspection before, during, and after completion of the installation; and(i) system maintenance requirements.

Before a rehabilitation strategy is developed, an assessment of the existing structure or elements shall be conducted in accordance with Section 14.

Lt E

eFRP FRP

=( )

233000 58.

(Replaces p. 724, November 2006)724

Single user license only. S

torage, distribution or use on network prohibited

Page 102: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Name

Organization

Address

City

Province/State

Country Postal/Zip Code

E-mail

I consent to CSA collecting and using the above information to send me updates relating to this publication.

Visit CSA’s policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.

CAN/CSA-S6-06

CSA Standards Update Service

CAN/CSA-S6-06November 2006

Title: Canadian Highway Bridge Design CodePagination: 788 pages (lv preliminary and 733 text), each dated November 2006

Automatic notifications about any updates to this publication are available.

• To register for e-mail notifications, and/or to download any existing updates in PDF, enter the Online Store at www.ShopCSA.ca and click on My Account on the navigation bar.

The List ID for this document is 2018339.

• To receive printed updates, please complete and return the attached card.

Single user license only. S

torage, distribution or use on network prohibited.

Page 103: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Affranchirsuffisamment

PlaceStamp Here

ASSOCIATION CANADIENNE DENORMALISATIONBUREAU CENTRAL DE L’INFORMATION5060, SPECTRUM WAY, BUREAU 100MISSISSAUGA ON L4W 5N6CANADA

CANADIAN STANDARDSASSOCIATIONCONSOLIDATED MAILING LIST5060 SPECTRUM WAY, SUITE 100MISSISSAUGA ON L4W 5N6CANADA

Single user license only. S

torage, distribution or use on network prohibited.

Page 104: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Legal Notice for Standards

Canadian Standards Association (CSA) standards are developed through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing varied viewpoints and interests to achieve consensus and develop a standard. Although CSA administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.

Disclaimer and exclusion of liabilityThis document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this document’s fitness for a particular purpose or use, its merchantability, or its non-infringement of any third party’s intellectual property rights. CSA does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA makes no representations or warranties regarding this document’s compliance with any applicable statute, rule, or regulation.

IN NO EVENT SHALL CSA, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.

In publishing and making this document available, CSA is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document.

CSA is a private not-for-profit company that publishes voluntary standards and related documents. CSA has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes.

Intellectual property rights and ownershipAs between CSA and the users of this document (whether it be in printed or electronic form), CSA is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA’s and/or others’ intellectual property and may give rise to a right in CSA and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA reserves all intellectual property rights in this document.

Patent rightsAttention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. CSA shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their own responsibility.

Authorized use of this documentThis document is being provided by CSA for informational and non-commercial use only. The user of this document is authorized to do only the following:

If this document is in electronic form:. load this document onto a computer for the sole purpose of reviewing it;. search and browse this document; and. print this document.

Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA to have such copies, and only if this Legal Notice appears on each such copy.

In addition, users may not and may not permit others to. alter this document in any way or remove this Legal Notice from the attached standard;. sell this document without authorization from CSA; or. make an electronic copy of this document.

If you do not agree with any of the terms and conditions contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.

Single user license only. S

torage, distribution or use on network prohibited.

Page 105: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

The Canadian Standards Association (CSA), under whose auspices this National Standard has been produced, was chartered in 1919 and accredited by the Standards Council of Canada to the National Standards system in 1973. It is a not-for-profit, nonstatutory, voluntary membership association engaged in standards development and certification activities. CSA standards reflect a national consensus of producers and users — including manufacturers, consumers, retailers, unions and professional organizations, and governmental agencies. The standards are used widely by industry and commerce and often adopted by municipal, provincial, and federal governments in their regulations, particularly in the fields of health, safety, building and construction, and the environment. Individuals, companies, and associations across Canada indicate their support for CSA’s standards development by volunteering their time and skills to CSA Committee work and supporting the Association’s objectives through sustaining memberships. The more than 7000 committee volunteers and the 2000 sustaining memberships together form CSA’s total membership from which its Directors are chosen. Sustaining memberships represent a major source of income for CSA’s standards development activities. The Association offers certification and testing services in support of and as an extension to its standards development activities. To ensure the integrity of its certification process, the Association regularly and continually audits and inspects products that bear the CSA Mark. In addition to its head office and laboratory complex in Toronto, CSA has regional branch offices in major centres across Canada and inspection and testing agencies in eight countries. Since 1919, the Association has developed the necessary expertise to meet its corporate mission: CSA is an independent service organization whose mission is to provide an open and effective forum for activities facilitating the exchange of goods and services through the use of standards, certification and related services to meet national and international needs. For further information on CSA services, write toCanadian Standards Association5060 Spectrum Way, Suite 100Mississauga, Ontario, L4W 5N6Canada

The Standards Council of Canada (SCC) is thecoordinating body of the National StandardsSystem, a coalition of independent, autonomousorganizations working towards the furtherdevelopment and improvement of voluntarystandardization in the national interest. The principal objects of the SCC are to fosterand promote voluntary standardization as a meansof advancing the national economy, benefiting thehealth, safety, and welfare of the public, assistingand protecting the consumer, facilitating domesticand international trade, and furthering internationalcooperation in the field of standards. A National Standard of Canada (NSC) is a standardprepared or reviewed by an accredited Standards Development Organization (SDO) and approved by the SCC according to the requirements of CAN-P-2. Approval does not refer to the technical content of the standard; this remains the continuing responsibility of the SDO. An NSC reflects a consensus of a number of capable individuals whose collective interests provide, to the greatest practicable extent, a balance of representation of general interests, producers, regulators, users (including consumers), and others with relevant interests, as may be appropriate to the subject in hand. It normally is a standard which is capable of making a significant and timely contribution to the national interest. Those who have a need to apply standards areencouraged to use NSCs. These standards are subjectto periodic review. Users of NSCs are cautionedto obtain the latest edition from the SDO which publishes the standard. The responsibility for approving standards as National Standards of Canada rests with theStandards Council of Canada270 Albert Street, Suite 200Ottawa, Ontario, K1P 6N7Canada

Cette Norme nationale du Canada est offerte en anglais et en français.

Although the intended primary application of this Standard is stated in its Scope, it is importantto note that it remains the responsibility of the users to judge its suitability for their particular purpose.

®Registered trade-mark of Canadian Standards Association

Single user license only. S

torage, distribution or use on network prohibited.

Page 106: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Approved byStandards Council of Canada

National Standard of Canada

Published in November 2006 by Canadian Standards AssociationA not-for-profit private sector organization

5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N61-800-463-6727 • 416-747-4044

Visit our Online Store at www.ShopCSA.ca

CAN/CSA-S6-06Canadian Highway Bridge Design Code

Prepared by

Single user license only. S

torage, distribution or use on network prohibited.

Page 107: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

To purchase CSA Standards and related publications, visit CSA’s Online Store at www.ShopCSA.ca or call toll-free 1-800-463-6727 or 416-747-4044.

ISBN 1-55436-252-0Technical Editor: Mark Braiter

© Canadian Standards Association — 2006

All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher.

This publication is printed on Rolland Enviro100, which contains 100% recycled post-consumer fibre, is EcoLogo and Processed Chlorine Free certified, and was manufactured using biogas energy.

100%

Single user license only. S

torage, distribution or use on network prohibited.

Page 108: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

November 2006 iii

Contents

© Canadian Standards Association Canadian Highway Bridge Design Code

Technical Committee on the Canadian Highway Bridge Design Code xxx

Subcommittee on Section 1 — General xxxii

Subcommittee on Section 2 — Durability xxxiii

Subcommittee on Section 3 — Loads xxxiv

Subcommittee on Section 4 — Seismic design xxxv

Subcommittee on Section 5 — Methods of analysis xxxvi

Subcommittee on Section 6 — Foundations xxxvii

Subcommittee on Section 7 — Buried structures xxxviii

Subcommittee on Section 8 — Concrete structures xxxix

Subcommittee on Section 9 — Wood structures xl

Subcommittee on Section 10 — Steel structures xli

Subcommittee on Section 11 — Joints and bearings xlii

Subcommittee on Section 12 — Barriers and highway accessory supports xliii

Subcommittee on Section 13 — Movable bridges xliv

Subcommittee on Section 14 — Evaluation xlv

Subcommittee on Section 15 — Rehabilitation and repair xlvi

Subcommittee on Section 16 — Fibre-reinforced structures xlvii

Code Calibration Task Force xlviii

Editorial Task Force xlix

French Translation Task Force l

Regulatory Authority Committee li

Preface lii

Foreword lv

Section 1 — General 11.1 Scope 21.1.1 Scope of Code 21.1.2 Scope of this Section 21.1.3 Terminology 21.2 Reference publications 2

Single user license only. S

torage, distribution or use on network prohibited.

Page 109: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

iv November 2006

1.3 Definitions 101.3.1 General 101.3.2 General administrative definitions 101.3.3 General technical definitions 101.3.4 Hydraulic definitions 151.4 General requirements 161.4.1 Approval 161.4.2 Design 171.4.3 Evaluation and rehabilitation of existing bridges 181.4.4 Construction 181.5 Geometry 201.5.1 Planning 201.5.2 Structure geometry 201.6 Barriers 201.6.1 Superstructure barriers 201.6.2 Roadside substructure barriers 201.6.3 Structure protection in waterways 211.6.4 Structure protection at railways 211.7 Auxiliary components 211.7.1 Expansion joints and bearings 211.7.2 Approach slabs 211.7.3 Utilities on bridges 211.8 Durability and maintenance 221.8.1 Durability and protection 221.8.2 Bridge deck drainage 221.8.3 Maintenance 241.9 Hydraulic design 251.9.1 Design criteria 251.9.2 Investigations 261.9.3 Location and alignment 261.9.4 Estimation of scour 261.9.5 Protection against scour 271.9.6 Backwater 291.9.7 Soffit elevation 291.9.8 Approach grade elevation 301.9.9 Channel erosion control 301.9.10 Stream stabilization works and realignment 311.9.11 Culverts 31

Section 2 — Durability 332.1 Scope 342.2 Definitions 342.3 Design for durability 342.3.1 Design concept 342.3.2 Durability requirements 342.3.3 Structural materials 362.4 Aluminum 362.4.1 Deterioration mechanisms 362.4.2 Detailing for durability 362.5 Polychloroprene and polyisoprene 372.6 Polytetrafluoroethylene (PTFE) 372.7 Waterproofing membranes 372.8 Backfill material 372.9 Soil and rock anchors 372.10 Other materials 37

Single user license only. S

torage, distribution or use on network prohibited.

Page 110: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 v

Section 3 — Loads 393.1 Scope 413.2 Definitions 413.3 Abbreviations and symbols 433.3.1 Abbreviations 433.3.2 Symbols 433.4 Limit states criteria 473.4.1 General 473.4.2 Ultimate limit states 473.4.3 Fatigue limit state 473.4.4 Serviceability limit states 473.5 Load factors and load combinations 483.5.1 General 483.5.2 Permanent loads 503.5.3 Transitory loads 513.5.4 Exceptional loads 513.6 Dead loads 513.7 Earth loads and secondary prestress loads 523.7.1 Earth loads 523.7.2 Secondary prestress effects 523.8 Live loads 523.8.1 General 523.8.2 Design lanes 523.8.3 CL-W loading 523.8.4 Application 543.8.5 Centrifugal force 563.8.6 Braking force 563.8.7 Curb load 563.8.8 Barrier loads 563.8.9 Pedestrian load 573.8.10 Maintenance access loads 573.8.11 Maintenance vehicle load 573.8.12 Multiple-use structures 573.9 Superimposed deformations 583.9.1 General 583.9.2 Movements and load effects 583.9.3 Superstructure types 583.9.4 Temperature effects 593.10 Wind loads 613.10.1 General 613.10.2 Design of the superstructure 623.10.3 Design of the substructure 633.10.4 Aeroelastic instability 643.10.5 Wind tunnel tests 653.11 Water loads 653.11.1 General 653.11.2 Static pressure 653.11.3 Buoyancy 653.11.4 Stream pressure 653.11.5 Wave action 663.11.6 Scour action 663.11.7 Debris torrents 663.12 Ice loads 673.12.1 General 67

Single user license only. S

torage, distribution or use on network prohibited.

Page 111: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

vi November 2006

3.12.2 Dynamic ice forces 673.12.3 Static ice forces 693.12.4 Ice jams 693.12.5 Ice adhesion forces 693.12.6 Ice accretion 693.13 Earthquake effects 693.14 Vessel collisions 703.14.1 General 703.14.2 Bridge classification 703.14.3 Assessment 703.14.4 Annual frequency of collapse 703.14.5 Design vessel 703.14.6 Application of collision forces 703.14.7 Protection of piers 713.15 Vehicle collision load 713.16 Construction loads and loads on temporary structures 713.16.1 General 713.16.2 Dead loads 713.16.3 Live loads 713.16.4 Segmental construction 713.16.5 Falsework 72

AnnexesA3.1 (normative) — Climatic and environmental data 73A3.2 (normative) — Wind loads on highway accessory supports and slender structural elements 94A3.3 (normative) — Vessel collision 104A3.4 (normative) — CL-625-ONT live loading 113

Section 4 — Seismic design 1154.1 Scope 1174.2 Definitions 1174.3 Abbreviation and symbols 1194.3.1 Abbreviation 1194.3.2 Symbols 1194.4 Earthquake effects 1224.4.1 General 1224.4.2 Importance categories 1224.4.3 Zonal acceleration ratio 1234.4.4 Seismic performance zones 1234.4.5 Analysis for earthquake loads 1234.4.6 Site effects 1254.4.7 Elastic seismic response coefficient 1264.4.8 Response modification factors 1274.4.9 Load factors and load combinations 1284.4.10 Design forces and support lengths 1284.5 Analysis 1324.5.1 General 1324.5.2 Single-span bridges 1324.5.3 Multi-span bridges 1334.6 Foundations 1344.6.1 General 1344.6.2 Liquefaction of foundation soils 1344.6.3 Stability of slopes 1354.6.4 Seismic forces on abutments and retaining walls 1354.6.5 Soil-structure interaction 135

Single user license only. S

torage, distribution or use on network prohibited.

Page 112: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 vii

4.6.6 Fill settlement and approach slabs 1354.7 Concrete structures 1354.7.1 General 1354.7.2 Seismic Performance Zone 1 1354.7.3 Seismic Performance Zone 2 1364.7.4 Seismic Performance Zones 3 and 4 1364.7.5 Piles 1384.8 Steel structures 1404.8.1 General 1404.8.2 Materials 1404.8.3 Sway stability effects 1404.8.4 Steel substructures 1404.8.5 Other systems 1444.9 Joints and bearings 1444.9.1 General 1444.9.2 Seismic design forces 1444.10 Seismic base isolation 1444.10.1 General 1444.10.2 Zonal acceleration ratio 1454.10.3 Seismic performance zones 1454.10.4 Site effects and site coefficient 1454.10.5 Response modification factors and design requirements for substructure 1454.10.6 Analysis procedures 1454.10.7 Clearance and design displacements for seismic and other loads 1484.10.8 Design forces for Seismic Performance Zone 1 1484.10.9 Design forces for Seismic Performance Zones 2, 3, and 4 1484.10.10 Other requirements 1484.10.11 Required tests of isolation system 1494.10.12 Elastomeric bearings — Design 1514.10.13 Elastomeric bearings — Construction 1524.10.14 Sliding bearings — Design 1534.10.15 Sliding bearings — Construction 1534.11 Seismic evaluation of existing bridges 1534.11.1 General 1534.11.2 Bridge classification 1534.11.3 Damage levels 1534.11.4 Performance criteria 1534.11.5 Evaluation methods 1534.11.6 Load factors and load combinations for seismic evaluation 1544.11.7 Minimum support length 1544.11.8 Member capacities 1544.11.9 Required response modification factor 1554.11.10 Response modification factor of existing substructure elements 1554.11.11 Evaluation acceptance criteria 1554.11.12 Other evaluation procedures 1564.11.13 Bridge access 1564.11.14 Liquefaction of foundation soils 1564.11.15 Soil-structure interaction 1564.12 Seismic rehabilitation 1564.12.1 Performance criteria 1564.12.2 Response modification factor for rehabilitation 1564.12.3 Seismic rehabilitation 1564.12.4 Seismic rehabilitation techniques 157

Single user license only. S

torage, distribution or use on network prohibited.

Page 113: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

viii November 2006

Section 5 — Methods of analysis 1595.1 Scope 1615.2 Definitions 1615.3 Abbreviations and symbols 1645.3.1 Abbreviations 1645.3.2 Symbols 1645.4 General requirements 1675.4.1 Application 1675.4.2 Analysis for limit states 1675.4.3 Modelling 1675.4.4 Structural responses 1675.4.5 Factors affecting structural responses 1705.4.6 Deformations 1705.4.7 Diaphragms and bracing systems 1705.4.8 Analysis of deck slabs 1715.4.9 Analysis for redistribution of force effects 1715.4.10 Analysis for accumulation of force effects due to construction sequence 1715.4.11 Analysis for effects of prestress 1715.4.12 Analysis for thermal effects 1715.4.13 Secondary stability effects 1715.5 Requirements for specific bridge types 1715.5.1 General 1715.5.2 Voided slab — Limitation on size of voids 1715.5.3 Deck-on-girder 1725.5.4 Truss and arch 1725.5.5 Rigid frame and integral abutment types 1725.5.6 Transverse wood deck 1725.5.7 Box girder 1725.5.8 Single-spine bridges 1735.6 Dead load 1735.6.1 Simplified methods of analysis (beam analogy method) 1735.6.2 Refined methods of analysis 1745.7 Live load 1745.7.1 Simplified methods of analysis 1745.7.2 Refined methods of analysis 2025.8 Idealization of structure and interpretation of results 2035.8.1 General 2035.8.2 Effective flange widths for bending 2035.8.3 Idealization for analysis 2075.9 Refined methods of analysis for short- and medium-span bridges 2075.9.1 Selection of methods of analysis 2075.9.2 Specific applications 2075.9.3 Model analysis 2075.10 Long-span bridges 2105.10.1 General 2105.10.2 Cable-stayed bridges 2105.10.3 Suspension bridges 2105.11 Dynamic analysis 2105.11.1 General requirements of structural analysis 2105.11.2 Elastic dynamic responses 2115.11.3 Inelastic-dynamic responses 2115.11.4 Analysis for collision loads 2115.11.5 Seismic analysis 2115.12 Stability and magnification of force effects 212

Single user license only. S

torage, distribution or use on network prohibited.

Page 114: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 ix

5.12.1 General 2125.12.2 Member stability analysis for magnification of member bending moments 2125.12.3 Structural stability analysis for lateral sway 2125.12.4 Structural stability analysis for assemblies of individual members 212

AnnexesA5.1 (normative) — Factors affecting structural response 213A5.2 (informative) — Two-dimensional analysis 217

Section 6 — Foundations 2256.1 Scope 2276.2 Definitions 2276.3 Abbreviations and symbols 2296.3.1 Abbreviations 2296.3.2 Symbols 2296.4 Design requirements 2306.4.1 Limit states 2306.4.2 Effects on surroundings 2316.4.3 Effects on structure 2316.4.4 Components 2316.4.5 Consultation 2316.4.6 Inspection and quality control 2316.5 Geotechnical investigation 2316.5.1 General 2316.5.2 Investigation procedures 2326.5.3 Geotechnical parameters 2326.5.4 Shallow foundations 2326.5.5 Deep foundations 2326.5.6 Report 2326.6 Resistance and deformation 2336.6.1 General 2336.6.2 Ultimate limit state 2336.6.3 Serviceability limit state 2346.7 Shallow foundations 2356.7.1 General 2356.7.2 Calculated geotechnical resistance at ULS 2356.7.3 Pressure distribution 2376.7.4 Effect of load inclination 2386.7.5 Factored geotechnical horizontal resistance 2396.8 Deep foundations 2406.8.1 General 2406.8.2 Selection of deep foundation units 2406.8.3 Vertical load transfer 2406.8.4 Downdrag 2406.8.5 Factored geotechnical axial resistance 2406.8.6 Group effects — Vertical loads 2416.8.7 Factored geotechnical lateral resistance 2416.8.8 Structural resistance 2426.8.9 Embedment and spacing 2426.8.10 Pile shoes and splices 2436.9 Lateral and vertical pressures 2436.9.1 General 2436.9.2 Lateral pressures 2436.9.3 Compaction surcharge 2446.9.4 Effects of loads 245

Single user license only. S

torage, distribution or use on network prohibited.

Page 115: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

x November 2006

6.9.5 Surcharge 2456.9.6 Wheel load distribution through fill 2456.10 Ground anchors 2466.10.1 Application 2466.10.2 Design 2466.10.3 Materials and installation 2466.10.4 Anchor testing 2476.11 Sheet pile structures 2476.11.1 Application 2476.11.2 Design 2476.11.3 Ties and anchors 2486.11.4 Cellular sheet pile structures 2486.12 MSE structures 2486.12.1 Application 2486.12.2 Design 2486.12.3 Backfill 2496.13 Pole foundations 2496.13.1 Application 2496.13.2 Design 249

Section 7 — Buried structures 2517.1 Scope 2527.2 Definitions 2527.3 Abbreviation and symbols 2547.3.1 Abbreviation 2547.3.2 Symbols 2547.4 Hydraulic design 2587.5 Structural design 2597.5.1 Limit states 2597.5.2 Load factors 2607.5.3 Material resistance factors 2607.5.4 Geotechnical considerations 2617.5.5 Seismic requirements 2627.5.6 Minimum clear spacing between conduits 2627.6 Soil-metal structures 2637.6.1 General 2637.6.2 Structural materials 2657.6.3 Design criteria 2667.6.4 Additional design requirements 2717.6.5 Construction 2737.6.6 Special features 2757.6.7 Site supervision and construction control 2757.7 Metal box structures 2767.7.1 General 2767.7.2 Structural materials 2767.7.3 Design criteria 2777.7.4 Additional design considerations 2787.7.5 Construction 2787.7.6 Special features 2797.7.7 Site supervision and construction control 2797.8 Reinforced concrete buried structures 2797.8.1 Standards for structural components 2797.8.2 Standards for joint gaskets for precast concrete units 2807.8.3 Installation criteria 2807.8.4 Loads and load combinations 287

Single user license only. S

torage, distribution or use on network prohibited.

Page 116: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xi

7.8.5 Earth pressure distribution from loads 2887.8.6 Analysis 2917.8.7 Ultimate limit state 2917.8.8 Strength design 2927.8.9 Serviceability limit state 2957.8.10 Fatigue limit state 2957.8.11 Minimum reinforcement 2957.8.12 Distribution reinforcement 2967.8.13 Details of the reinforcement 2967.8.14 Joint shear for top slab of precast concrete box sections with depth of cover less than 0.6 m 2977.8.15 Construction 297

Section 8 — Concrete structures 3018.1 Scope 3048.2 Definitions 3048.3 Symbols 3078.4 Materials 3138.4.1 Concrete 3138.4.2 Reinforcing bars and deformed wire 3168.4.3 Tendons 3168.4.4 Anchorages, mechanical connections, and ducts 3178.4.5 Grout 3188.4.6 Material resistance factors 3188.5 Limit states 3198.5.1 General 3198.5.2 Serviceability limit states 3198.5.3 Fatigue limit state 3198.5.4 Ultimate limit states 3208.6 Design considerations 3208.6.1 General 3208.6.2 Design 3208.6.3 Buckling 3238.7 Prestressing 3238.7.1 Stress limitations for tendons 3238.7.2 Concrete strength at transfer 3248.7.3 Grouting 3248.7.4 Loss of prestress 3248.8 Flexure and axial loads 3268.8.1 General 3268.8.2 Assumptions for the serviceability and fatigue limit states 3268.8.3 Assumptions for the ultimate limit states 3278.8.4 Flexural components 3278.8.5 Compression components 3288.8.6 Tension components 3318.8.7 Bearing 3318.9 Shear and torsion 3318.9.1 General 3318.9.2 Design procedures 3328.9.3 Sectional design model 3338.9.4 Slabs, walls, and footings 3378.9.5 Interface shear transfer 3378.10 Strut-and-tie model 3388.10.1 General 3388.10.2 Structural idealization 3388.10.3 Proportioning of a compressive strut 339

Single user license only. S

torage, distribution or use on network prohibited.

Page 117: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xii November 2006

8.10.4 Proportioning of a tension tie 3408.10.5 Proportioning of node regions 3408.10.6 Crack control reinforcement 3408.11 Durability 3418.11.1 Deterioration mechanisms 3418.11.2 Protective measures 3418.11.3 Detailing for durability 3468.12 Control of cracking 3478.12.1 General 3478.12.2 Distribution of reinforcement 3478.12.3 Reinforcement 3478.12.4 Crack control in the side faces of beams 3488.12.5 Flanges of T-beams 3488.12.6 Shrinkage and temperature reinforcement 3488.13 Deformation 3488.13.1 General 3488.13.2 Dimensional changes 3498.13.3 Deflections and rotations 3498.14 Details of reinforcement and special detailing requirements 3508.14.1 Hooks and bends 3508.14.2 Spacing of reinforcement 3518.14.3 Transverse reinforcement for flexural components 3528.14.4 Transverse reinforcement for compression components 3528.14.5 Reinforcement for shear and torsion 3538.14.6 Maximum spacing of reinforcement for shear and torsion 3538.15 Development and splices 3538.15.1 Development 3538.15.2 Development of reinforcing bars and deformed wire in tension 3558.15.3 Development of reinforcing bars in compression 3568.15.4 Development of pretensioning strand 3578.15.5 Development of standard hooks in tension 3578.15.6 Combination development length 3588.15.7 Development of welded wire fabric in tension 3588.15.8 Mechanical anchorages 3588.15.9 Splicing of reinforcement 3588.16 Anchorage zone reinforcement 3608.16.1 General 3608.16.2 Post-tensioning anchorage zones 3608.16.3 Pretensioning anchorage zones 3638.16.4 Inclined anchorages 3638.16.5 Intermediate anchorages 3638.16.6 Anchorage blisters 3638.16.7 Anchorage of attachments 3638.17 Seismic design and detailing 3668.18 Special provisions for deck slabs 3678.18.1 Design methods 3678.18.2 Minimum slab thickness 3678.18.3 Allowance for wear 3678.18.4 Empirical design method 3678.18.5 Diaphragms 3708.18.6 Edge stiffening 3708.18.7 Distribution reinforcement 3708.19 Composite construction 3728.19.1 General 372

Single user license only. S

torage, distribution or use on network prohibited.

Page 118: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xiii

8.19.2 Flexure 3728.19.3 Shear 3728.19.4 Semi-continuous structures 3728.20 Concrete girders 3738.20.1 General 3738.20.2 Effective flange width for T- and box girders 3738.20.3 Flange thickness for T- and box girders 3738.20.4 Isolated girders 3738.20.5 Top and bottom flange reinforcement for cast-in-place T- and box girders 3738.20.6 Post-tensioning tendons 3748.20.7 Diaphragms 3748.21 Multi-beam decks 3748.22 Segmental construction 3748.22.1 General 3748.22.2 Additional ducts and anchorages 3748.22.3 Diaphragms 3758.22.4 Deviators for external tendons 3758.22.5 Coupling of post-tensioning tendons 3758.22.6 Special provisions for various bridge types 3758.22.7 Precast segmental beam bridges 3778.23 Concrete piles 3788.23.1 General 3788.23.2 Specified concrete strength 3788.23.3 Handling 3788.23.4 Splices 3788.23.5 Pile dimensions 3788.23.6 Non-prestressed concrete piles 3788.23.7 Prestressed concrete piles 379

Section 9 — Wood structures 3819.1 Scope 3849.2 Definitions 3849.3 Symbols 3869.4 Limit states 3889.4.1 General 3889.4.2 Serviceability limit states 3889.4.3 Ultimate limit states 3889.4.4 Resistance factor 3889.5 General design 3899.5.1 Design assumption 3899.5.2 Spans 3899.5.3 Load-duration factor 3899.5.4 Size-effect factors 3899.5.5 Service condition 3899.5.6 Load-sharing factor 3899.5.7 Notched components 3909.5.8 Butt joint stiffness factor 3909.5.9 Treatment factor 3919.6 Flexure 3919.6.1 Flexural resistance 3919.6.2 Size effect 3919.6.3 Lateral stability 3919.7 Shear 3929.7.1 Shear resistance 3929.7.2 Size effect 392

Single user license only. S

torage, distribution or use on network prohibited.

Page 119: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xiv November 2006

9.7.3 Shear force and shear load 3929.7.4 Shear modulus 3929.7.5 Vertically laminated decks 3929.8 Compression members 3939.8.1 General 3939.8.2 Compressive resistance parallel to grain 3939.8.3 Slenderness effect 3949.8.4 Amplified moments 3969.8.5 Rigorous evaluation of amplified moments 3969.8.6 Approximate evaluation of amplified moments 3989.9 Tension members 3999.10 Compression at an angle to grain 4009.11 Sawn wood 4019.11.1 Materials 4019.11.2 Specified strengths and moduli of elasticity 4019.12 Glued-laminated timber 4049.12.1 Materials 4049.12.2 Specified strengths and moduli of elasticity 4049.12.3 Vertically laminated beams 4059.12.4 Camber 4059.12.5 Varying depth 4059.12.6 Curved members 4069.13 Structural composite lumber 4069.13.1 Materials 4069.13.2 Specified strengths and moduli of elasticity 4069.14 Wood piles 4069.14.1 Materials 4069.14.2 Splicing 4069.14.3 Specified strengths and moduli of elasticity 4069.14.4 Design 4079.15 Fastenings 4079.15.1 General 4079.15.2 Design 4089.15.3 Construction 4089.16 Hardware and metalwork 4089.17 Durability 4089.17.1 General 4089.17.2 Pedestrian contact 4089.17.3 Incising 4089.17.4 Fabrication 4099.17.5 Pressure preservative treatment of laminated veneer lumber 4099.17.6 Pressure preservative treatment of parallel strand lumber 4099.17.7 Field treatment 4099.17.8 Treated round wood piles 4099.17.9 Untreated round wood piles 4099.17.10 Pile heads 4099.17.11 Protective treatment of hardware and metalwork 4099.17.12 Stress-laminated timber decking 4109.18 Wood cribs 4109.18.1 General 4109.18.2 Member sizes and assembly 4109.18.3 Fastening 4109.18.4 Load transfer to cribs 4109.19 Wood trestles 411

Single user license only. S

torage, distribution or use on network prohibited.

Page 120: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xv

9.19.1 General 4119.19.2 Pile bents 4119.19.3 Framed bents 4119.19.4 Caps 4119.19.5 Bracing 4119.20 Stringers and girders 4119.20.1 Design details 4119.20.2 Diaphragms 4129.21 Nail-laminated wood decks 4129.21.1 General 4129.21.2 Transversely laminated wood decks 4129.21.3 Longitudinal nail-laminated wood decks 4139.22 Wood-concrete composite decks 4139.22.1 General 4139.22.2 Wood base 4139.22.3 Concrete slab 4149.22.4 Wood-concrete interface 4159.22.5 Factored moment resistance 4169.23 Stress-laminated wood decks 4179.23.1 General 4179.23.2 Post-tensioning materials 4179.23.3 Design of post-tensioning system 4179.23.4 Design of distribution bulkhead 4199.23.5 Laminated decks 4219.23.6 Net section 4229.23.7 Hardware durability 4229.23.8 Design details 4239.24 Wearing course 4239.25 Drainage 4239.25.1 General 4239.25.2 Deck 424

Section 10 — Steel structures 42510.1 Scope 42810.2 Definitions 42810.3 Abbreviations and symbols 43010.3.1 Abbreviations 43010.3.2 Symbols 43010.4 Materials 43710.4.1 General 43710.4.2 Structural steel 43710.4.3 Cast steel 43710.4.4 Stainless steel 43710.4.5 Bolts 43710.4.6 Welding electrodes 43710.4.7 Stud shear connectors 43710.4.8 Cables 43710.4.9 High-strength bars 43810.4.10 Galvanizing and metallizing 43810.4.11 Identification 43810.4.12 Coefficient of thermal expansion 43810.5 Design theory and assumptions 43810.5.1 General 43810.5.2 Ultimate limit states 43810.5.3 Serviceability limit states 438

Single user license only. S

torage, distribution or use on network prohibited.

Page 121: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xvi November 2006

10.5.4 Fatigue limit state 43910.5.5 Fracture control 43910.5.6 Seismic requirements 43910.5.7 Resistance factors 43910.5.8 Analysis 43910.5.9 Design lengths of members 43910.6 Durability 44010.6.1 General 44010.6.2 Corrosion as a deterioration mechanism 44010.6.3 Corrosion protection 44010.6.4 Superstructure components 44010.6.5 Other components 44110.6.6 Areas inaccessible after erection 44410.6.7 Detailing for durability 44410.7 Design detail 44410.7.1 General 44410.7.2 Minimum thickness of steel 44410.7.3 Floor beams and diaphragms at piers and abutments 44410.7.4 Camber 44510.7.5 Welded attachments 44510.8 Tension members 44610.8.1 General 44610.8.2 Axial tensile resistance 44710.8.3 Axial tension and bending 44710.8.4 Tensile resistance of cables 44810.9 Compression members 44810.9.1 General 44810.9.2 Width-to-thickness ratio of elements in compression 44810.9.3 Axial compressive resistance 45010.9.4 Axial compression and bending 45110.9.5 Composite columns 45310.10 Beams and girders 45510.10.1 General 45510.10.2 Class 1 and 2 sections 45510.10.3 Class 3 sections 45710.10.4 Stiffened plate girders 45710.10.5 Shear resistance 45810.10.6 Intermediate transverse stiffeners 45910.10.7 Longitudinal web stiffeners 46010.10.8 Bearing stiffeners 46110.10.9 Lateral bracing, cross-frames, and diaphragms 46210.11 Composite beams and girders 46310.11.1 General 46310.11.2 Proportioning 46310.11.3 Effects of creep and shrinkage 46310.11.4 Control of permanent deflections 46310.11.5 Class 1 and Class 2 sections 46310.11.6 Class 3 sections 46710.11.7 Stiffened plate girders 46910.11.8 Shear connectors 47010.11.9 Lateral bracing, cross-frames, and diaphragms 47110.12 Composite box girders 47110.12.1 General 47110.12.2 Effective width of tension flanges 471

Single user license only. S

torage, distribution or use on network prohibited.

Page 122: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xvii

10.12.3 Web plates 47110.12.4 Flange-to-web welds 47110.12.5 Moment resistance 47210.12.6 Diaphragms, cross-frames, and lateral bracing 47410.12.7 Multiple box girders 47510.12.8 Single box girders 47510.13 Horizontally curved girders 47610.13.1 General 47610.13.2 Special considerations 47610.13.3 Design theory 47710.13.4 Bearings 47710.13.5 Diaphragms, cross-frames, and lateral bracing 47710.13.6 Steel I-girders 47810.13.7 Composite box girders 48010.13.8 Camber 48210.14 Trusses 48210.14.1 General 48210.14.2 Built-up members 48210.14.3 Bracing 48310.15 Arches 48410.15.1 General 48410.15.2 Width-to-thickness ratios 48410.15.3 Longitudinal web stiffeners 48410.15.4 Axial compression and bending 48410.15.5 Arch ties 48510.16 Orthotropic decks 48510.16.1 General 48510.16.2 Effective width of deck 48510.16.3 Superposition of local and global effects 48510.16.4 Deflection 48610.16.5 Girder diaphragms 48610.16.6 Design detail requirements 48610.16.7 Wearing surface 48710.17 Structural fatigue 48810.17.1 General 48810.17.2 Live-load-induced fatigue 48810.17.3 Distortion-induced fatigue 50010.17.4 Orthotropic decks 50110.18 Splices and connections 50110.18.1 General 50110.18.2 Bolted connections 50210.18.3 Welds 50410.18.4 Detailing of bolted connections 50510.18.5 Connection reinforcement and stiffening 50810.19 Anchors 50910.19.1 General 50910.19.2 Anchor bolt resistance 50910.20 Pins, rollers, and rockers 51010.20.1 Bearing resistance 51010.20.2 Pins 51010.21 Torsion 51110.21.1 General 51110.21.2 Members of closed cross-section 51110.21.3 Members of open cross-section 512

Single user license only. S

torage, distribution or use on network prohibited.

Page 123: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xviii November 2006

10.22 Piles 51310.22.1 Steel piles 51310.22.2 Effective length 51310.22.3 Splices 51310.22.4 Composite tube piles 51310.23 Fracture control 51310.23.1 General 51310.23.2 Identification 51310.23.3 Fracture toughness 51310.23.4 Welding of fracture-critical and primary tension members 51510.23.5 Welding corrections and repairs to fracture-critical members 51610.23.6 Non-destructive testing of fracture-critical members 51910.24 Construction requirements for structural steel 51910.24.1 General 51910.24.2 Submissions 51910.24.3 Materials 52010.24.4 Fabrication 52010.24.5 Welded construction 52310.24.6 Bolted construction 52410.24.7 Tolerances 52710.24.8 Quality control 52810.24.9 Transportation and delivery 52910.24.10 Erection 529

Section 11 — Joints and bearings 53111.1 Scope 53211.2 Definitions 53211.3 Abbreviations and symbols 53311.3.1 Abbreviations 53311.3.2 Symbols 53411.4 Common requirements 53411.4.1 General 53411.4.2 Design requirements 53511.5 Deck joints 53511.5.1 General requirements 53511.5.2 Selection 53611.5.3 Design 53711.5.4 Fabrication 53711.5.5 Installation 53811.5.6 Joint seals 53811.5.7 Sealed joint drainage 53811.5.8 Open joint drainage 53811.5.9 Volume control joint 53811.6 Bridge bearings 53811.6.1 General 53811.6.2 Metal back, roller, and spherical bearings 53911.6.3 Sliding surfaces 54011.6.4 Spherical bearings 54311.6.5 Pot bearings 54411.6.6 Elastomeric bearings 54511.6.7 Disc bearings 54811.6.8 Guides for lateral restraints 54911.6.9 Other bearing systems 55011.6.10 Load plates and attachment for bearings 550

Single user license only. S

torage, distribution or use on network prohibited.

Page 124: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xix

Section 12 — Barriers and highway accessory supports 55112.1 Scope 55212.2 Definitions 55212.3 Abbreviations and symbols 55312.3.1 Abbreviations 55312.3.2 Symbols 55312.4 Barriers 55412.4.1 General 55412.4.2 Barrier joints 55412.4.3 Traffic barriers 55412.4.4 Pedestrian barriers 56212.4.5 Bicycle barriers 56312.4.6 Combination barriers 56412.5 Highway accessory supports 56412.5.1 General 56412.5.2 Vertical clearances 56412.5.3 Maintenance 56412.5.4 Aesthetics 56412.5.5 Design 56412.5.6 Breakaway supports 56612.5.7 Foundations 56612.5.8 Corrosion protection 56712.5.9 Minimum thicknesses 56712.5.10 Camber 56712.5.11 Connections 567

Section 13 — Movable bridges 56913.1 Scope 57213.2 Definitions 57213.3 Symbols 57213.4 Materials 57313.4.1 General 57313.4.2 Structural steel 57313.4.3 Concrete 57313.4.4 Timber 57413.4.5 Carbon steel 57413.4.6 Forged steel 57413.4.7 Cast steel or iron 57413.4.8 Bronze 57413.4.9 Bolts 57413.4.10 Wire rope 57413.5 General design requirements 57413.5.1 General 57413.5.2 Type of deck 57413.5.3 Piers and abutments 57413.5.4 Navigation requirements 57413.5.5 Vessel collision 57413.5.6 Protection of traffic 57513.5.7 Fire protection 57513.5.8 Time of operation 57513.5.9 Aligning and locking 57513.5.10 Houses for machinery, electrical equipment, and operators 57513.5.11 New devices 57513.5.12 Access for routine maintenance 57513.5.13 Durability 576

Single user license only. S

torage, distribution or use on network prohibited.

Page 125: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xx November 2006

13.6 Movable bridge components 57613.6.1 General features 57613.6.2 Swing bridge components 58013.6.3 Bascule bridge components 58313.6.4 Rolling lift bridge components 58313.6.5 Vertical lift bridge components 58413.7 Structural analysis and design 58913.7.1 General 58913.7.2 Design theory and assumptions 58913.7.3 Wind loads 58913.7.4 Seismic loads 59013.7.5 Reaction due to temperature differential 59013.7.6 Hydraulic cylinder connections 59113.7.7 Loads on end floor beams and stringer brackets 59113.7.8 Swing bridges — Ultimate limit states 59113.7.9 Bascule (including rolling lift) bridges — Ultimate limit states 59213.7.10 Vertical lift bridges — Ultimate limit states 59313.7.11 Dead load factor 59313.7.12 All movable bridges — Ultimate limit states 59413.7.13 Special types of movable bridges 59413.7.14 Load effects 59413.7.15 Fatigue limit state 59413.7.16 Friction 59413.7.17 Machinery supports 59413.7.18 Vertical lift bridge towers 59413.7.19 Transitory loads 59413.8 Mechanical system design 59413.8.1 General 59413.8.2 Operating machinery 59513.8.3 Power sources 59513.8.4 Prime mover 59513.8.5 Power requirements for main machinery 59613.8.6 Wedges 59613.8.7 Brakes 59713.8.8 Frictional resistance 59813.8.9 Torque 59913.8.10 Application of worker power 60113.8.11 Machinery loads 60113.8.12 Allowable stresses for machinery and allowable hydraulic pressures 60113.8.13 Bearing pressures (moving surfaces) 60313.8.14 Line-bearing pressure 60513.8.15 Design of wire ropes 60513.8.16 Shafting 60713.8.17 Machinery fabrication and installation 60813.8.18 Lubrication 61413.8.19 Power equipment 61513.8.20 Quality of work 61713.9 Hydraulic system design 61813.10 Electrical system design 61913.10.1 General 61913.10.2 Canadian Electrical Code, Part I 61913.10.3 General requirements for electrical installation 61913.10.4 Working drawings 62013.10.5 Motor and generator tests 620

Single user license only. S

torage, distribution or use on network prohibited.

Page 126: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxi

13.10.6 Motors — General requirements 62113.10.7 Motor torque for span operation 62113.10.8 Motor temperature, insulation, and service factor 62213.10.9 Number of motors 62213.10.10 Synchronizing motors for tower-drive vertical lift bridges 62213.10.11 Speed of motors 62213.10.12 Gear motors 62213.10.13 Engine-generator sets 62213.10.14 Automatic electric power transfer 62313.10.15 Electrically operated motor brakes 62413.10.16 Electrically operated machinery brakes 62513.10.17 Design of electrical parts 62513.10.18 Electrical control 62513.10.19 Speed control for span-driving motors 62713.10.20 Master switches and relays for span-driving motors 62813.10.21 Programmable logic controllers 62813.10.22 Resistances and reactors 62813.10.23 Limit switches 62913.10.24 Interlocking 62913.10.25 Switches 62913.10.26 Circuit breakers and fuses 63013.10.27 Contact areas 63013.10.28 Magnetic contactors 63013.10.29 Overload relays 63013.10.30 Shunt coils 63013.10.31 Instruments 63013.10.32 Protection of electrical equipment 63113.10.33 Cast iron in electrical parts 63113.10.34 Position indicators and meters 63113.10.35 Indicating lights 63113.10.36 Control console 63113.10.37 Control panels 63213.10.38 Enclosures for panel boards 63213.10.39 Electrical wires and cables 63213.10.40 Tagging of wires 63313.10.41 Wire splices and connections 63313.10.42 Raceways, metal conduits, conduit fittings, and boxes 63313.10.43 Electrical connections between fixed and moving parts 63413.10.44 Electrical connections across the navigable channel 63513.10.45 Service lights 63513.10.46 Navigation lights 63613.10.47 Aircraft warning lights 63613.10.48 Circuits 63613.10.49 Grounding and lightning protection 63613.10.50 Spare parts 63613.11 Construction 63713.11.1 Shop assemblies 63713.11.2 Coating 63713.11.3 Erection 63713.12 Training and start-up assistance 63913.13 Operating and maintenance manual 63913.14 Inspection 640

Single user license only. S

torage, distribution or use on network prohibited.

Page 127: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xxii November 2006

Section 14 — Evaluation 64114.1 Scope 64314.2 Definitions 64314.3 Symbols 64314.4 General requirements 64614.4.1 Exclusions 64614.4.2 Expertise 64614.4.3 Future growth of traffic or future deterioration 64714.5 Evaluation procedures 64714.5.1 General 64714.5.2 Limit states 64714.5.3 Condition data 64714.5.4 Procedures 64814.5.5 Bridge posting 64814.6 Condition inspection 64814.6.1 General 64814.6.2 Plans 64814.6.3 Physical features 64814.6.4 Deterioration 64914.7 Material strengths 64914.7.1 General 64914.7.2 Review of original construction documents 64914.7.3 Analysis of tests of samples 64914.7.4 Strengths based on date of construction 65014.7.5 Deteriorated material 65114.8 Permanent loads 65114.8.1 General 65114.8.2 Dead load 65114.8.3 Earth pressure and hydrostatic pressure 65214.8.4 Shrinkage, creep, differential settlement, and bearing friction 65214.8.5 Secondary effects from prestressing 65214.9 Transitory loads 65214.9.1 Normal traffic 65214.9.2 Permit — Vehicle loads 65614.9.3 Dynamic load allowance for permit vehicle loads and alternative loading 65714.9.4 Multiple-lane loading 65714.9.5 Loads other than traffic 65814.10 Exceptional loads 65914.11 Lateral distribution categories for live load 65914.11.1 General 65914.11.2 Statically determinate method 65914.11.3 Sophisticated method 65914.11.4 Simplified method 65914.12 Target reliability index 65914.12.1 General 65914.12.2 System behaviour 66014.12.3 Element behaviour 66014.12.4 Inspection level 66014.12.5 Important structures 66014.13 Load factors 66114.13.1 General 66114.13.2 Permanent loads 66214.13.3 Transitory loads 66214.14 Resistance 665

Single user license only. S

torage, distribution or use on network prohibited.

Page 128: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxiii

14.14.1 General 66514.14.2 Resistance adjustment factor 67214.14.3 Effects of defects and deterioration 67314.15 Live load capacity factor 67414.15.1 General 67414.15.2 Ultimate limit states 67414.15.3 Serviceability limit states 67514.15.4 Combined load effects 67514.16 Load testing 67514.16.1 General 67514.16.2 Instrumentation 67614.16.3 Test load 67614.16.4 Application of load test results 67614.17 Bridge posting 67714.17.1 General 67714.17.2 Calculation of posting loads 67714.17.3 Posting signs 67814.18 Fatigue 679

AnnexesA14.1 (normative) — Equivalent material strengths from tests of samples 680A14.2 (normative) — Evaluation Level 1 (vehicle trains) in Ontario 682A14.3 (normative) — Evaluation Level 2 (two-unit vehicles) in Ontario 683A14.4 (normative) — Evaluation Level 3 (single-unit vehicles) in Ontario 684

Section 15 — Rehabilitation and repair 68715.1 Scope 68815.2 Symbols 68815.3 General requirements 68815.3.1 Limit states 68815.3.2 Condition data 68815.3.3 Rehabilitation loads and load factors 68815.3.4 Analysis 68815.3.5 Factored resistances 68815.3.6 Fatigue 68815.3.7 Bridge posting 68915.3.8 Seismic upgrading 68915.4 Special considerations 68915.5 Data collection 68915.6 Rehabilitation loads and load factors 68915.6.1 Loads 68915.6.2 Load factors and load combinations 69115.7 Analysis 69215.8 Resistance 69215.8.1 Existing members 69215.8.2 New members 692

Section 16 — Fibre-reinforced structures 69316.1 Scope 69516.1.1 Components 69516.1.2 Fibres 69516.1.3 Matrices 69516.1.4 Uses requiring Approval 69516.2 Definitions 69516.3 Abbreviations and symbols 697

Single user license only. S

torage, distribution or use on network prohibited.

Page 129: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xxiv November 2006

16.3.1 Abbreviations 69716.3.2 Symbols 69816.4 Durability 70116.4.1 FRP tendons, primary reinforcement, and strengthening systems 70116.4.2 FRP secondary reinforcement 70116.4.3 Fibres in FRC 70116.4.4 Cover to reinforcement 70216.4.5 Protective measures 70216.4.6 Allowance for wear in deck slabs 70216.4.7 Detailing of concrete components for durability 70216.4.8 Handling, storage, and installation of fibre tendons and primary reinforcement 70216.5 Fibre-reinforced polymers 70216.5.1 Material properties 70216.5.2 Confirmation of the specified tensile strength 70216.5.3 Resistance factor 70316.6 Fibre-reinforced concrete 70316.6.1 General 70316.6.2 Fibre volume fraction 70316.6.3 Fibre dispersion in concrete 70416.7 Externally restrained deck slabs 70416.7.1 General 70416.7.2 Full-depth cast-in-place deck slabs 70516.7.3 Cast-in-place deck slabs on stay-in-place formwork 70616.7.4 Full-depth precast concrete deck slabs 70616.8 Concrete beams and slabs 71116.8.1 General 71116.8.2 Deformability and minimum reinforcement 71116.8.3 Non-prestressed reinforcement 71216.8.4 Development length for FRP bars and tendons 71216.8.5 Development length for FRP grids 71216.8.6 Tendons 71216.8.7 Design for shear 71316.8.8 Internally restrained cast-in-place deck slabs 71416.9 Stressed wood decks 71516.9.1 General 71516.9.2 Post-tensioning materials 71516.9.3 Post-tensioning system 71516.9.4 Stressing procedure 71616.9.5 Design of bulkheads 71616.9.6 Stressed log bridges 71616.10 Barrier walls 71816.11 Rehabilitation of existing concrete structures with FRP 71916.11.1 General 71916.11.2 Flexural and axial load rehabilitation 72016.11.3 Shear rehabilitation with externally bonded FRP systems 72216.12 Rehabilitation of timber bridges 72416.12.1 General 72416.12.2 Strengthening for flexure 72516.12.3 Strengthening for shear 726

AnnexesA16.1 (normative) — Installation of FRP strengthening systems 729A16.2 (normative) — Quality control for FRP strengthening systems 732

Single user license only. S

torage, distribution or use on network prohibited.

Page 130: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxv

Tables1.1 — Highway classes 173.1 — Load factors and load combinations 493.2 — Permanent loads — Maximum and minimum values of load factors for ULS 503.3 — Unit material weights 513.4 — Number of design lanes 523.5 — Modification factor for multi-lane loading 553.6 — Loads on traffic barriers 573.7 — Maximum and minimum effective temperatures 593.8 — Wind exposure coefficient, Ce 623.9 — Modification of wind loads on superstructure with skew angle 643.10 — Longitudinal drag coefficient, CD 663.11 — Lateral load coefficient, CL 664.1 — Seismic performance zones 1234.2 — Minimum analysis requirements for multi-span bridges 1244.3 — Regular bridge requirements 1254.4 — Site coefficient, S 1254.5 — Response modification factor, R 1274.6 — Modification factor, K 1314.7 — Site coefficient for seismic isolation design, Si 1454.8 — Damping coefficient, B 1474.9 — Minimum analysis requirements for evaluation 1545.1 — Structural responses 1685.2 — Superstructure categories for simplified methods of analysis for live load 1755.3 — F and Cf for longitudinal bending moments in shallow superstructures corresponding to ultimate

and serviceability limit states 1775.4 — F and Cf for longitudinal bending moments in shallow superstructures corresponding to the fatigue

limit state 1855.5 — Ce for longitudinal bending moments in shallow superstructures corresponding to the fatigue and

vibration limit state 1875.6 — F and Cf for longitudinal moments in multi-spine bridges 1895.7 — F for longitudinal vertical shear corresponding to ultimate and serviceability limit states, m 1915.8 — F for longitudinal vertical shear corresponding to fatigue limit state, m 1925.9 — F for longitudinal vertical shear in multi-spine bridges 1935.10 — Maximum cantilever moments, My , due to unfactored CL-625 Truck wheel loads (DLA included),

kN•m/m 1965.11 — Effective deck plate width for a longitudinal rib 2055.12 — Selection of methods of analysis 2086.1 — Geotechnical resistance factors 2346.2 — Equivalent fluid pressure per metre width, kPa/m 2447.1 — Requirements for cut ends 2587.2 — Specific limit states 2607.3 — Material resistance factors 2617.4 — Soil classifications 2657.5 — Secant modulus of soil, Es , for various soils 2667.6 — Values for k4 for calculating equivalent line loads 2707.7 — Minimum transverse distance of backfill in single-conduit soil-metal structures 2757.8 — Standards for precast buried concrete structures 2807.9 — Classification of placed soils 2807.10 — Soils and compaction requirements for standard installations for circular precast concrete

pipes 2837.11 — Soils and compaction requirements for standard installations for concrete boxes 2847.12 — Vertical and horizontal arching factors for circular concrete pipes in standard installations 2877.13 — Vertical and horizontal arching factors for box sections in standard installations 288

Single user license only. S

torage, distribution or use on network prohibited.

Page 131: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xxvi November 2006

7.14 — Force factors for earth loads 2897.15 — Earth pressure factors 2897.16 — Length factors for earth pressures 2907.17 — Crack-control coefficient, C1 2957.18 — Shrinkage and temperature reinforcement 2968.1 — Material resistance factors 3198.2 — Prestressing tendon stress limits 3248.3 — Friction factors 3258.4 — Maximum water to cementing materials ratio 3418.5 — Minimum concrete covers and tolerances 3448.6 — Maximum crack width 3478.7 — Minimum bend diameter, mm 3508.8 — Minimum development length of reinforcing bars and deformed wire in tension 3558.9 — Modification factors for development length 3568.10 — Modification factors for hook development length 3578.11 — Classification of lap splices in tension 3598.12 — Construction tolerances 3779.1 — Resistance factor for wood components, φ 3899.2 — Load-sharing factor for bending, shear, and tension for all species and grades 3909.3 — Values of De 3909.4 — Size-effect factors ksb for flexure and ksv for shear for all species and grades 3919.5 — Modification factor for lateral stability, kls 3929.6 — Minimum values of the effective length factor, k 3959.7 — A, S, and eo for piles at 0.55 of the effective length below the butt joint 3979.8 — η to be used in calculating Pcr for piles 3999.9 — Size-effect factor, kst , for tension at net section in dimension lumber 4009.10 — Size-effect factor for bearing, ksq 4009.11 — Permitted species and species combinations for sawn wood 4019.12 — Specified strengths and moduli of elasticity for structural joists and planks, MPa 4029.13 — Specified strengths and moduli of elasticity for beam and stringer grades, MPa 4039.14 — Specified strengths and moduli of elasticity for post and timber grades, MPa 4049.15 — Specified strengths and moduli of elasticity for glued-laminated Douglas fir timber, MPa 4059.16 — Typical specified strengths and moduli of elasticity for structural composite lumber, MPa 4069.17 — Specified strengths and moduli of elasticity for round wood piles, MPa 4079.18 — Limiting pressure perpendicular to grain, fql, MPa 4199.19 — Minimum section properties for steel channel bulkheads 42010.1 — Corrosion protection for superstructure components 44210.2 — Corrosion protection for other components 44310.3 — Width-to-thickness ratio of elements in compression 44910.4 — Fatigue life constants and constant amplitude threshold stress ranges 48910.5 — Values of Nd 49010.6 — Average daily truck traffic 49010.7 — Detail categories for load-induced fatigue 49110.8 — Detail categories for load-induced fatigue of orthotropic decks 49810.9 — Values of ks and c1 50310.10 — Matching electrode classifications for CSA G40.21 and CSA W59 steels 50410.11 — Minimum edge distance for bolt holes 50710.12 — Impact test temperatures and Charpy impact energy requirements for fracture-critical

members 51410.13 — Impact test temperatures and Charpy impact energy requirements for primary tension

members 51510.14 — Impact test temperatures and Charpy impact energy requirements for weld metal 51510.15 — Preheat and interpass temperature for steel grades 51810.16 — Minimum elapsed time for acceptance testing 519

Single user license only. S

torage, distribution or use on network prohibited.

Page 132: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxvii

10.17 — Minimum bend radii for bent plates 52110.18 — Nut rotation from snug-tight condition 52510.19 — Facing of bearing surfaces roughness requirements 52711.1 — Dimensions for confined sheet PTFE 54111.2 — Dimensions for stainless steel 54111.3 — Maximum average contact pressure for PTFE, MPa 54211.4 — Design coefficient of friction 54311.5 — Physical properties of polyisoprene and polychloroprene 54612.1 — Highway type factors, Kh 55512.2 — Highway curvature factors, Kc 55512.3 — Highway grade factors, Kg 55612.4 — Superstructure height factors, Ks 55612.5 — Optimum performance levels — Barrier clearance less than or equal to 2.25 m 55712.6 — Optimum performance levels — Barrier clearance greater than 2.25 m and less than or equal to

3.75 m 55812.7 — Optimum performance levels — Barrier clearance greater than 3.75 m 55912.8 — Minimum barrier heights, H 56012.9 — Strengths for aluminum castings 56513.1 — Maximum tensile strength for Grade 1770 bright wire 58613.2 — Maximum tensile strength for Grade 110/120 bright wire 58613.3 — Swing bridges — Special load combinations and load factors 59113.4 — Bascule (including rolling lift) bridges — Special load combinations and load factors 59213.5 — Vertical lift bridges — Special load combinations and load factors 59313.6 — Dead load factor, αD 59313.7 — Coefficients of friction 59813.8 — Machinery losses and efficiency coefficients 59913.9 — Coefficients of friction for sliding span locks and end and centre wedges 59913.10 — Maximum allowable stresses in trunnions, MPa (psi) 60213.11 — Maximum allowable stresses for machinery parts other than trunnions, MPa (psi) 60213.12 — Maximum bearing pressures 60413.13 — Ultimate stress and ultimate strength of steel wire rope of 6 × 19 classification and 6 × 25 filler

construction 60613.14 — Permissible stresses in gear teeth 61213.15 — Fits and finishes 61814.1 — Properties of structural steel 65014.2 — Minimum yield strengths of reinforcing steel, MPa 65114.3 — Modification factors for multiple-lane loading 65814.4 — Fraction of CL1-W loading to be applied in the other lanes 65814.5 — Target reliability index, β , for normal traffic and for PA, PB, and PS traffic 66114.6 — Target reliability index, β , for PC traffic 66114.7 — Maximum dead load factors, αD 66214.8 — Live load factors, α L, for normal traffic (Evaluation Levels 1, 2, and 3) for all types of analysis 66214.9 — Live load factors, α L, for normal traffic (alternative loading) for all types of analysis 66314.10 — Live load factors, α L, for PA traffic 66314.11 — Live load factors, α L, for PB traffic 66414.12 — Live load factors, α L, for PC traffic 66414.13 — Live load factors, α L, for PS traffic 66414.14 — Specified strengths and moduli of elasticity for beam and stringer grades and post and timber

grades, MPa 67214.15 — Resistance adjustment factor, U 67315.1 — Rehabilitation design live loads for restricted normal traffic 69016.1 — Conditions of use for FRP tendons and primary reinforcement 70116.2 — φFRP for pultruded FRP and aramid fibre rope 70316.3 — Minimum values of Ri for various applications 704

Single user license only. S

torage, distribution or use on network prohibited.

Page 133: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xxviii November 2006

16.4 — Maximum permissible stresses in FRP tendons at jacking and transfer for concrete beams and slabs for pretensioning and post-tensioning systems 713

16.5 — Values of KbFRP 725

Figures3.1 — Deflection limits for highway bridge superstructure vibration 483.2 — CL-W Truck 533.3 — CL-W Lane Load 543.4 — Maintenance vehicle load 583.5 — Modifications to maximum and minimum effective temperatures 593.6 — Temperature differentials for Type A and C superstructures 603.7 — Pier nose angle and subtended nose angle for calculating forces due to moving ice 684.1 — Dimensions for minimum support lengths 1315.1 — DVE for slab-on-girder bridges 1885.2 — Calculation of A 1955.3 — Notation for cantilever moments 1965.4 — Values of k for calculating transverse vertical shear in shear-connected beam bridges 2005.5 — be and b for various cross-sections 2045.6 — Effective width of orthotropic deck 2066.1 — Failure mechanism for footing 2366.2 — Footing under eccentric load 2366.3 — Bearing coefficients 2376.4 — Eccentricity limit 2386.5 — Load inclination reduction factors for bearing resistance, φ’ = 30° 2396.6 — Compaction effects 2457.1 — Dh and Dv for various shapes of pipe 2647.2 — Values of Af 2677.3 — Depth of cover, H and Hmin , for soil-metal structures and metal box structures 2727.4 — Trench reinforcement for the foundation of pipe-arches 2737.5 — Longitudinal seam bolting arrangements 2747.6 — Metal box structure dimensional limits 2767.7 — Minimum extent of structural backfill for metal box structures 2797.8 — Terminology and standard installations for circular precast concrete pipes on embankments 2817.9 — Terminology and standard installations for circular precast concrete pipes in trenches 2827.10 — Standard installations for concrete box sections on embankments 2857.11 — Standard installations for concrete box sections in trenches 2867.12 — Earth pressure distribution for standard installations of circular concrete pipes (force diagram) 2897.13 — Lateral earth loads and pressure distribution on concrete box sections due to approaching wheel

loads 2918.1 — Magnitude of thrust 3228.2 — Eccentricity of curved tendons 3238.3 — Influence of reinforcement on spacing of diagonal cracks 3348.4 — Influence of anchorage conditions on effective cross-sectional area of strut 3398.5 — Reinforcement in cast-in-place deck slab 3688.6 — Reinforcement for cast-in-place deck slabs designed using the empirical method 3698.7 — Reinforcement for cast-in-place deck slabs on precast panels 3698.8 — Edge stiffening at transverse free edges 3719.1 — Connection of nail-laminated deck to steel beam 4139.2 — Spliced butt joint 4149.3 — Details of wood-concrete interface 4159.4 — Alternative details of wood-concrete interface 4169.5 — External post-tensioning system 4189.6 — Internal post-tensioning system 4189.7 — Protection for external post-tensioning system 423

Single user license only. S

torage, distribution or use on network prohibited.

Page 134: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxix

10.1 — Class 1 and 2 sections in positive moment regions 46510.2 — Class 1 and 2 sections in negative moment regions 46610.3 — Class 3 Sections in positive moment regions 46810.4 — Class 3 Sections in negative moment regions 46910.5 — Detailing requirements for orthotropic decks 48710.6 — Detail categories for load-induced fatigue 49411.1 — Maximum average pressure on a layer of elastomeric bearing at SLS without rotation 54812.1 — Application of traffic design loads to traffic barriers 56212.2 — Application of pedestrian and bicycle design loads to barriers 56314.1 — Level 1 evaluation loads with CL1-W Truck 65314.2 — Level 2 evaluation loads with CL2-W Truck 65414.3 — Level 3 evaluation loads with CL3-W Truck 65514.4 — Deck punching shear for composite slabs 66714.5 — Deck punching shear for non-composite slabs 66814.6 — Spacing requirements for minimum reinforcement, mm 67014.7 — Spacing requirements for minimum reinforcement as a fraction of shear depth 67114.8 — Posting loads for gross vehicle weight 67816.1 — Distance between the deck slab and the top of the supporting beam 70716.2 — Detail of transverse edge stiffening 70716.3 — Detail of transverse edge stiffening 70816.4 — Detail of transverse edge stiffening 70816.5 — Detail of transverse edge stiffening 70916.6 — External transverse restraining system consisting of connected straps 70916.7 — External transverse confining system consisting of indirectly connected partially studded

straps 71016.8 — External transverse confining system in longitudinal negative moment regions 71016.9 — Post-tensioning system for stressed log bridges 71616.10 — Spliced butt joint for logs 71716.11 — Cross-section of a barrier wall reinforced with GFRP 71916.12 — Anchorage methods in the compression zone of externally bonded FRP shear reinforcement 72316.13 — Cross-section of a timber beam with GFRP NSMR 72616.14 — Elevation of timber beam with GFRP sheets for shear strengthening 72716.15 — Elevation of timber beam with GFRP bars for shear strengthening 728

Single user license only. S

torage, distribution or use on network prohibited.

Page 135: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xxx November 2006

Technical Committee on the Canadian Highway Bridge Design Code

J. Francis Nova Scotia Department of Transportation and Public Works,Halifax, Nova Scotia

Chair

B. Bakht JMBT Structures Research Inc.,Toronto, Ontario

Vice-Chair

G. Richard Ministère des transports du Québec,Québec, Québec

Vice-Chair

T.B. Tharmabala Ontario Ministry of Transportation,St. Catharines, Ontario

Vice-Chair

H. Yea Saskatchewan Highways and Transportation,Regina, Saskatchewan

Vice-Chair

A.C. Agarwal Brampton, Ontario

W.V. Anderson Delcan Corporation,Markham, Ontario

D. Bagnariol Ontario Ministry of Transportation,St. Catharines, Ontario

Associate

N. Banthia University of British Columbia,Vancouver, British Columbia

Associate

F.M. Bartlett University of Western Ontario,London, Ontario

D. Beaulieu Centre de recherche industrielle du Québec,Ste-Foy, Québec

G.P. Carlin Les Ponts Jacques Cartier et Champlain Incorporée,Longueuil, Québec

Associate

M.S. Cheung University of Ottawa,Ottawa, Ontario

C. Clarke Alberta Infrastructure and Transportation,Edmonton, Alberta

D. Cogswell New Brunswick Department of Transportation,Fredericton, New Brunswick

Associate

Single user license only. S

torage, distribution or use on network prohibited.

Page 136: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxxi

D. Dundas Ontario Ministry of Transportation,Toronto, Ontario

Associate

D.J. Evans Prince Edward Island Department of Transportation and Public Works,Charlottetown, Prince Edward Island

P. Gauvreau University of Toronto,Toronto, Ontario

Associate

A. Ho Ontario Ministry of Transportation,Toronto, Ontario

K.C. Johns Université de Sherbrooke,Sherbrooke, Québec

C. Lam Ontario Ministry of Transportation,St. Catharines, Ontario

P. Lepper Canadian Wood Council,Ottawa, Ontario

D. Macleod Public Works and Government Services Canada,Gatineau, Québec

B. Massicotte École Polytechnique de Montréal,Montréal, Québec

R. Mathieson British Columbia Ministry of Transportation,Victoria, British Columbia

R.J. McGrath Cement Association of Canada,Ottawa, Ontario

D. Mitchell McGill University,Montréal, Québec

A.A. Mufti University of Manitoba,Winnipeg, Manitoba

A. Nelson Manitoba Department of Highways and Transportation,Winnipeg, Manitoba

R.J. Ramsay UMA Engineering Limited,Edmonton, Alberta

Associate

J.A. Skeet Dillon Consulting Limited,Calgary, Alberta

Associate

A.F. Wong Canadian Institute of Steel Construction,Toronto, Ontario

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 137: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xxxii November 2006

Subcommittee on Section 1 — General

A. Ho Ontario Ministry of Transportation,Toronto, Ontario

Chair

J. Doering University of Manitoba,Winnipeg, Manitoba

H. Farghaly Ontario Ministry of Transportation,St. Catharines, Ontario

R. Haynes Ontario Ministry of Transportation,St. Catharines, Ontario

R. Richardson Manitoba Department of Highways and Transportation,Winnipeg, Manitoba

D.M. Tran Ministère des transports du Québec,Québec, Québec

R. Walters Stantec Consulting Limited,Edmonton, Alberta

E. Waschuk Alberta Infrastructure and Transportation,Edmonton, Alberta

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 138: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxxiii

Subcommittee on Section 2 — Durability

N. Banthia University of British Columbia,Vancouver, British Columbia

Chair

G.E. Brudermann Frido Consulting,Halfmoon Bay, British Columbia

P.D. Carter CH2M HILL Canada,Vancouver, British Columbia

D. Conte Ontario Ministry of Transportation,Toronto, Ontario

O.E. Gjorv Norwegian University of Science and Technology,Trondheim, Norway

J. Kroman City of Calgary,Calgary, Alberta

Z. Lounis National Research Council Canada,Ottawa, Ontario

P. McGrath McGrath Engineering Ltd.,North Vancouver, British Columbia

S. Mindess University of British Columbia,Vancouver, British Columbia

K. Sakai Kagawa University,Takamatsu, Japan

G. Tadros STECO Engineering Ltd.,Calgary, Alberta

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 139: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xxxiv November 2006

Subcommittee on Section 3 — Loads

A.C. Agarwal Brampton, Ontario Chair

A. Au Ontario Ministry of Transportation,St. Catharines, Ontario

D.P. Gagnon Buckland & Taylor Ltd.,North Vancouver, British Columbia

J.P. Grenier Ministère des transports du Québec,Québec, Québec

P. King University of Western Ontario,London, Ontario

C. Lam Ontario Ministry of Transportation,St. Catharines, Ontario

D. Mitchell McGill University,Montréal, Québec

R.H. Pion Public Works and Government Services Canada,Gatineau, Québec

G. Van Der Vinne Northwest Hydraulic Consultants Ltd.,Edmonton, Alberta

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 140: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxxv

Subcommittee on Section 4 — Seismic design

D. Mitchell McGill University,Montréal, Québec

Chair

M.U. Atukorala Golder Associates Ltd.,Burnaby, British Columbia

D. Bagnariol Ontario Ministry of Transportation,St. Catharines, Ontario

M. Bruneau University at Buffalo,Buffalo, New York, USA

A. Heidebrecht McMaster University,Hamilton, Ontario

D. Kennedy Associated Engineering Ltd.,Burnaby, British Columbia

N. Theodor Ontario Ministry of Transportation,St. Catharines, Ontario

R. Tremblay École Polytechnique de Montréal,Montréal, Québec

S. Zhu Buckland & Taylor Ltd.,North Vancouver, British Columbia

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 141: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xxxvi November 2006

Subcommittee on Section 5 — Methods of analysis

B. Massicotte École Polytechnique de Montréal,Montréal, Québec

Chair

J. Au Ontario Ministry of Transportation,St. Catharines, Ontario

T. Chicoine SNC-Lavalin Inc.,Montréal, Québec

J.P. Grenier Ministère des transports du Québec,Québec, Québec

J. Newhook Dalhousie University,Halifax, Nova Scotia

S. Sabanathan Ontario Ministry of Transportation,St. Catharines, Ontario

M. Talbot Ministère des transports du Québec,Québec, Québec

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 142: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxxvii

Subcommittee on Section 6 — Foundations

D. Dundas Ontario Ministry of Transportation,Toronto, Ontario

Chair

A. Altaee Urkkada Technology,Ottawa, Ontario

M.U. Atukorala Golder Associates Ltd.,Burnaby, British Columbia

P. Branco Thurber Engineering Limited,Oakville, Ontario

G. Fenton Dalhousie University,Halifax, Nova Scotia

R. Green Waterloo, Ontario

I. Husain Ontario Ministry of Transportation,St. Catharines, Ontario

I. Leclerc Ministère des transports du Québec,Québec, Québec

P. Ojala Lea Consulting Limited,Markham, Ontario

D. Woeller ConeTec Investigations Ltd.,Vancouver, British Columbia

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 143: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xxxviii November 2006

Subcommittee on Section 7 — Buried structures

B. Bakht JMBT Structures Research Inc.,Toronto, Ontario

Chair

G. Abdel-Sayed Bloomfield Hills, Michigan, USA

J. Au Ontario Ministry of Transportation,St. Catharines, Ontario

K. Bontius Hatch, Mott & MacDonald,Mississauga, Ontario

W. Brockbank Reinforced Earth Company Ltd.,Mississauga, Ontario

M. Gergely Ontario Ministry of Transportation,St. Catharines, Ontario

W. Kenedi Ontario Ministry of Transportation,St. Catharines, Ontario

E. Kling Centennial Concrete Pipe & Products Inc.,Cambridge, Ontario

I. Leclerc Ministère des transports du Québec,Québec, Québec

J. Meyboom Delcan Corporation,New Westminster, British Columbia

C. Mirza Toronto, Ontario

I. Moore Queen’s University,Kingston, Ontario

T. Morrison Atlantic Industries Limited,Cambridge, Ontario

J. Newhook Dalhousie University,Halifax, Nova Scotia

P. Sheehan Armtec Limited Partnership,Guelph, Ontario

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 144: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xxxix

Subcommittee on Section 8 — Concrete structures

P. Gauvreau University of Toronto,Toronto, Ontario

Chair

D. Bernard Ministère des transports du Québec,Québec, Québec

M.P. Collins University of Toronto,Toronto, Ontario

H. Ibrahim Buckland & Taylor Ltd.,North Vancouver, British Columbia

W. Leblanc Con-Force Structures Limited,Calgary, Alberta

R.J. McGrath Cement Association of Canada,Ottawa, Ontario

M. Meleka Ontario Ministry of Transportation,St. Catharines, Ontario

D.M. Rogowsky UMA Engineering Ltd.,Edmonton, Alberta

R. Stofco McCormick Rankin Corporation,Mississauga, Ontario

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 145: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xl November 2006

Subcommittee on Section 9 — Wood structures

K.C. Johns Université de Sherbrooke,Sherbrooke, Québec

Chair

B. Bakht JMBT Structures Research Inc.,Toronto, Ontario

L.M. Bélanger Ministère des transports du Québec,Québec, Québec

R.M.G. Britton University of Manitoba,Winnipeg, Manitoba

G.E. Brudermann Frido Consulting,Halfmoon Bay, British Columbia

R.J. Eden Manitoba Floodway Authority,Winnipeg, Manitoba

M. Erki Royal Military College of Canada,Kingston, Ontario

R.O. Foschi University of British Columbia,Vancouver, British Columbia

R. Krisciunas Ontario Ministry of Transportation,Thunder Bay, Ontario

P. Lepper Canadian Wood Council,Ottawa, Ontario

I. Sturrock British Columbia Ministry of Transportation,Victoria, British Columbia

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 146: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xli

Subcommittee on Section 10 — Steel structures

D. Beaulieu Centre de recherche industrielle du Québec,Ste-Foy, Québec

Chair

D. Francis Supreme Steel Ltd.,Edmonton, Alberta

G. Grondin University of Alberta,Edmonton, Alberta

H. Hawk Delcan Corporation,Calgary, Alberta

J. Labbé Ministère des transports du Québec,Québec, Québec

N. Theodor Ontario Ministry of Transportation,St. Catharines, Ontario

R. Vincent Canam Group Inc.,Boucherville, Québec

A.F. Wong Canadian Institute of Steel Construction,Toronto, Ontario

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 147: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xlii November 2006

Subcommittee on Section 11 — Joints and bearings

J.A. Skeet Dillon Consulting Limited,Calgary, Alberta

Chair

J. Labbé Ministère des transports du Québec,Québec, Québec

R. Mihaljevic Ontario Ministry of Transportation,St. Catharines, Ontario

N. Patel Ontario Ministry of Transportation,St. Catharines, Ontario

J.F. Reysset Goodco Ltée,Laval, Québec

R. Yu Alberta Infrastructure and Transportation,Edmonton, Alberta

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 148: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xliii

Subcommittee on Section 12 — Barriers and highway accessory supports

R.J. Ramsay UMA Engineering Limited,Edmonton, Alberta

Chair

D. Beaulieu Centre de recherche industrielle du Québec,Ste-Foy, Québec

M. Blouin Ministère des transports du Québec,Québec, Québec

R. Haynes Ontario Ministry of Transportation,St. Catharines, Ontario

M. Vallières Ministère des transports du Québec,Québec, Québec

R. Yu Alberta Infrastructure and Transportation,Edmonton, Alberta

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 149: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xliv November 2006

Subcommittee on Section 13 — Movable bridges

T.B. Tharmabala Ontario Ministry of Transportation,St. Catharines, Ontario

Chair

D. Campbell Klohn-Krippen Consultants Ltd.,Vancouver, British Columbia

R. Clayton Byrne Engineering Inc.,Burlington, Ontario

J. Crabb Delcan Corporation,Markham, Ontario

D. Dixon McCormick Rankin Corporation,Mississauga, Ontario

L. Huang Modjeski and Masters,Mechanicsburg, Pennsylvania, USA

Q. Islam Ontario Ministry of Transportation,Kingston, Ontario

W. McCraken Byrne Engineering Inc.,Burlington, Ontario

J. Saweczko Byrne Engineering Inc.,Burlington, Ontario

P.M. Skelton Hardesty & Hanover,New York, New York, USA

A. Zaki SNC-Lavalin Inc.,Montréal, Québec

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 150: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xlv

Subcommittee on Section 14 — Evaluation

D. Bagnariol Ontario Ministry of Transportation,St. Catharines, Ontario

Chair

F.M. Bartlett University of Western Ontario,London, Ontario

D.P. Gagnon Buckland & Taylor Ltd.,North Vancouver, British Columbia

J.P. Grenier Ministère des transports du Québec,Québec, Québec

B. Higgins CBCL Limited,Halifax, Nova Scotia

W. Kenedi Ontario Ministry of Transportation,St. Catharines, Ontario

C. Lam Ontario Ministry of Transportation,St. Catharines, Ontario

J. Meyboom Delcan Corporation,New Westminster, British Columbia

P. Ojala Lea Consulting Limited,Markham, Ontario

R.J. Ramsay UMA Engineering Limited,Edmonton, Alberta

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 151: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xlvi November 2006

Subcommittee on Section 15 — Rehabilitation and repair

F.M. Bartlett University of Western Ontario,London, Ontario

Chair

D. Dixon McCormick Rankin Corporation,Mississauga, Ontario

L. Feldman University of Saskatchewan,Saskatoon, Saskatchewan

D.P. Gagnon Buckland & Taylor Ltd.,North Vancouver, British Columbia

D. Lai Ontario Ministry of Transportation,St. Catharines, Ontario

K.W. Neale Université de Sherbrooke,Sherbrooke, Québec

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 152: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xlvii

Subcommittee on Section 16 — Fibre-reinforced structures

A.A. Mufti University of Manitoba,Winnipeg, Manitoba

Chair

B. Bakht JMBT Structures Research Inc.,Toronto, Ontario

N. Banthia University of British Columbia,Vancouver, British Columbia

B. Benmokrane Université de Sherbrooke,Sherbrooke, Québec

G. Desgagné Ministère des transports du Québec,Québec, Québec

R.J. Eden Manitoba Floodway Authority,Winnipeg, Manitoba

M. Erki Royal Military College of Canada,Kingston, Ontario

V. Karbhari University of California at San Diego,La Jolla, California, USA

J. Kroman City of Calgary,Calgary, Alberta

D. Lai Ontario Ministry of Transportation,St. Catharines, Ontario

A. Machida Saitama University,Urawa, Japan

K.W. Neale Université de Sherbrooke,Sherbrooke, Québec

G. Tadros STECO Engineering Ltd.,Calgary, Alberta

B. Taljsten BYG-DTU,Lyngby, Denmark

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 153: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

xlviii November 2006

Code Calibration Task Force

A.C. Agarwal Brampton, Ontario Chair

A. Au Ontario Ministry of Transportation,St. Catharines, Ontario

D. Becker Golder Associates Ltd.,Calgary, Alberta

R.O. Foschi University of British Columbia,Vancouver, British Columbia

D.P. Gagnon Buckland & Taylor Ltd.,North Vancouver, British Columbia

H. Hong University of Western Ontario,London, Ontario

P. King University of Western Ontario,London, Ontario

C. Lam Ontario Ministry of Transportation,St. Catharines, Ontario

D. Mitchell McGill University,Montréal, Québec

A.S. Nowak University of Nebraska,Lincoln, Nebraska, USA

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 154: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 xlix

Editorial Task Force

M. Erki Royal Military College of Canada,Kingston, Ontario

Chair

B. Bakht JMBT Structures Research Inc.,Toronto, Ontario

L.G. Jaeger Halifax, Nova Scotia

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 155: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

l November 2006

French Translation Task Force

G. Desgagné Ministère des transports du Québec,Québec, Québec

Chair

L.M. Bélanger Ministère des transports du Québec,Québec, Québec

D. Bernard Ministère des transports du Québec,Québec, Québec

M. Blouin Ministère des transports du Québec,Québec, Québec

J.P. Grenier Ministère des transports du Québec,Québec, Québec

J. Labbé Ministère des transports du Québec,Québec, Québec

M. Lacroix Ministère des transports du Québec,Québec, Québec

J. Prévost Ministère des transports du Québec,Québec, Québec

M. Savard Ministère des transports du Québec,Québec, Québec

M. Vallières Ministère des transports du Québec,Québec, Québec

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 156: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 li

Regulatory Authority Committee

G. Richard Ministère des transports du Québec,Québec, Québec

Chair

J. Francis Nova Scotia Department of Transportation and Public Works,Halifax, Nova Scotia

Vice-Chair

T.B. Tharmabala Ontario Ministry of Transportation,St. Catharines, Ontario

Vice-Chair

B. Bakht JMBT Structures Research Inc.,Toronto, Ontario

Associate

G.P. Carlin Les Ponts Jacques Cartier et Champlain Incorporée,Longueuil, Québec

C. Clarke Alberta Infrastructure and Transportation,Edmonton, Alberta

D. Cogswell New Brunswick Department of Transportation,Fredericton, New Brunswick

D.J. Evans Prince Edward Island Department of Transportation and Public Works,Charlottetown, Prince Edward Island

A. Ikpong Yukon Department of Highways and Public Works,Whitehorse, Yukon

D. Macleod Public Works and Government Services Canada,Gatineau, Québec

R. Mathieson British Columbia Ministry of Transportation,Victoria, British Columbia

D. Power Newfoundland and Labrador Department of Transportation and Works,St. John’s, Newfoundland and Labrador

R. Richardson Manitoba Department of Highways and Transportation,Winnipeg, Manitoba

D.R. Sitland Government of Nunavut,Iqaluit, Nunavut

T. Williams Government of the Northwest Territories,Yellowknife, Northwest Territories

H. Yea Saskatchewan Highways and Transportation,Regina, Saskatchewan

M. Braiter CSA,Mississauga, Ontario

Project Manager

Single user license only. S

torage, distribution or use on network prohibited.

Page 157: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

lii November 2006

Preface

This is the tenth edition of CAN/CSA-S6, Canadian Highway Bridge Design Code. It supersedes the previous edition published in 2000, which amalgamated and superseded CAN/CSA-S6-88, Design of Highway Bridges, and the Ontario Ministry of Transportation’s OHBDC-91-01, Ontario Highway Bridge Design Code, 3rd ed. Earlier editions of the CSA Standard were published in 1978, 1974, 1966, 1952, 1938, 1929, and 1922. Earlier editions of the Ontario Highway Bridge Design Code were published in 1983 and 1979 by the Ontario Ministry of Transportation.

This Code uses the limit states design approach and reflects current design conditions across Canada as well as research activity since the publication of the previous edition. Several design aspects are addressed for the first time in this edition and a more detailed treatment of many areas is provided. This Code has been written to be applicable in all provinces and territories.

As in the previous edition, there are 16 Sections in this Code.Section 1 (“General”) specifies general requirements and includes definitions and a reference

publications clause applicable throughout this Code. It also specifies geometric requirements, based in part on the Transportation Association of Canada’s Geometric Design Guide for Canadian Roads (1999), and hydraulic design requirements, based in part on the Transportation Association of Canada’s Guide to Bridge Hydraulics, 2nd ed. (2001). There are also provisions covering durability, economics, environmental considerations, aesthetics, safety, maintenance, and maintenance inspection access.

Section 2 (“Durability”) addresses durability aspects of materials used in the construction of highway bridges, culverts, and other structures located in transportation corridors. The durability requirements for all of the materials are based on common principles applicable to the deterioration mechanisms for each material, the environmental conditions to which the materials are subjected, and the protective measures and detailing requirements needed to limit deterioration to acceptable levels.

Section 3 (“Loads”) specifies loading requirements for the design of new bridges, including requirements for permanent loads, live loads, and miscellaneous transitory and exceptional loads (but excluding seismic loads). The 625 kN truck load model and corresponding lane load model are specified as the minima for interprovincial transportation and are based on current Canadian legal loads. Ship collision provisions are also included in Section 3.

Section 3 no longer specifies limits on the span lengths for application of the truck and lane loads. Accordingly, long-span requirements have been developed and appear in Section 3 and elsewhere in this Code (these requirements, however, should not be considered comprehensive). Section 3 covers long-span live loading and addresses wind tunnel testing for aerodynamic effects.

Section 4 (“Seismic design”) specifies seismic design requirements for new bridges. These are based primarily on AASHTO (American Association of State Highway and Transportation Officials) LRFDEM-3-M, AASHTO LRFD Bridge Design Specifications, 3rd ed. (2005). Section 4 differs from AASHTO LRFDEM-3-M, however, by providing a more extensive treatment of the importance and response modification factors, new design and detailing requirements for structural steel ductile substructure elements, and design provisions for seismic base isolation. Section 4 also includes design provisions for the seismic evaluation of existing bridges and provisions pertaining to the seismic rehabilitation of existing bridges.

Section 5 (“Methods of analysis”) specifies requirements for analyzing the basic superstructure of a bridge. In its methods for simplified analysis of bridge superstructures, a bridge is treated as a single beam and force effects are averaged over the width of the bridge and subsequently amplified to calculate the true intensity. Distribution factors are based on research conducted up to the late 1990s. Simplified elastic methods are included for the analysis of transverse effects. Refined methods of analysis for short-, medium-, and long-span bridges are also addressed.

Section 6 (“Foundations”) is based, as in the previous edition, on the use of global resistance factors. Section 6 employs the limit states design approach, in which the term “resistance” is applied to the strength or capacity of the soil or rock at the ultimate limit state and the term “reaction” is associated with the serviceability limit state and is indicative of a particular deformation. Section 6 also emphasizes the importance of communication between the bridge structural engineer and the geotechnical engineer at all stages of a project.

Single user license only. S

torage, distribution or use on network prohibited.

Page 158: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 liii

Section 7 (“Buried structures”) deals with soil-metal structures with shallow corrugated plates in which thrust is the dominant force in the metal plates as well as soil-metal structures with deep corrugated plates and metal box structures in which flexural effects are also considered in the design of the metal plates. Provisions have been added for reinforced concrete precast and cast-in-place structures, including pipes, box sections, and segmental structures. Section 7 also specifies requirements for determining the properties and dimensions of the engineered soil and non-soil components and addresses construction supervision and construction procedures for soil components.

Section 8 (“Concrete structures”) covers reinforced and partially and fully prestressed concrete components (including deck slabs) made of normal-density, semi-low-density, and high-density concrete of a strength varying from 30 to 80 MPa. Compression field theory is used for proportioning for shear and for torsion combined with flexure. The strut-and-tie approach is used for proportioning regions where the plane sections assumption is not applicable.

Section 9 (“Wood structures”) specifies properties for materials and fastenings that are consistent with CAN/CSA-O86-01, Engineering Design in Wood, and includes data for structural composite lumber. Its provisions related to shear and compression, load distribution, design factors (in many cases), and laminated wood decks are essentially unchanged from those of the previous edition. The shear force concept has been reintroduced for the shear design of sawn wood members and the specified strength values in shear have been increased, in accordance with CAN/CSA-O86-01. In addition, the factors for load-sharing systems have changed.

Section 10 (“Steel structures”) specifies the majority of this Code’s design requirements for steel structures (with the exception of some seismic requirements specified in Section 4). Construction requirements that can have an impact on the resistance factors used in Section 10 are specified in Clause 10.24. Because this Code has been expanded to include long-span bridges, cables and arches are now dealt with. In addition, durability is now addressed much more fully and clauses dealing with beams and girders, composite beams and girders, horizontally curved girders, orthotropic decks, fatigue, and construction have been revised.

Section 11 (“Joints and bearings”) covers the deck joints and bearings most commonly used in Canada.Section 12 (“Barriers and highway accessory supports”) specifies crash test requirements for barriers and

breakaway highway accessory supports. Crash testing may be waived for barrier and accessory support designs that have a successful in-service performance record. Performance levels alternative to those specified in Section 12 are permitted if approved by the regulatory authority.

Section 13 (“Movable bridges”) specifies requirements for the design, construction, and operation of conventional movable bridges. Although the structural design aspects are based on the limit states design approach, the mechanical systems design aspects follow the working stress principle used in North American industry.

Section 14 (“Evaluation”) includes new provisions concerning the three-level evaluation system, evaluation of deck slabs, and detailed evaluation from bridge testing. The provisions on the strength of wood members and the shear resistance of concrete have been improved. Another category of permit vehicle (Permit — Annual or project [PA]) has been added. An optional probability-based mean load method that uses site-specific load and resistance information for more accurate evaluation is also provided. As in the previous edition, a more conventional approach to determining material grades from small samples is used in place of the Baye’s theorem approach in CAN/CSA-S6-88.

Section 15 (“Rehabilitation and repair”) specifies rehabilitation design requirements and provides guidance on the selection of loads and load factors for rehabilitation that is based on the intended use of the bridge following rehabilitation.

Section 16 (“Fibre-reinforced structures”) specifies design requirements for a limited number of structural components containing either high- or low-modulus fibres. The high-modulus fibres (aramid, carbon, and glass) are employed in fibre-reinforced polymers (FRPs), which are used as replacements for steel bars and tendons. The low-modulus fibres are used for controlling cracks in concrete. Section 16 covers concrete beams and slabs, concrete deck slabs, and stressed wood decks. In this edition, Section 16 includes new design provisions that permit glass-fibre-reinforced polymer to be used as primary reinforcement and as tendons in concrete.

Single user license only. S

torage, distribution or use on network prohibited.

Page 159: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

liv November 2006

Other new provisions in Section 16 permit the rehabilitation of concrete and timber structures using externally bonded FRP systems or near-surface-mounted reinforcement. The provisions concerning fibre-reinforced concrete deck slabs in the previous edition have been reorganized for this edition to include deck slabs of both cast-in-place and precast construction, which are now referred to as “externally restrained deck slabs”, whereas deck slabs containing internal FRP reinforcement are referred to as “internally restrained deck slabs”. The resistance factors of the previous edition have been revised and depend on conditions of use, with a further distinction made between factory- and field-produced FRPs. The previous edition’s deformability requirements for FRP-reinforced and FRP-prestressed concrete beams and slabs are now dealt with in separate clauses that cover design for deformability, minimum flexural resistance, and crack control reinforcement. The effect of the sustained loads on the strength of FRPs is accounted for in this edition by limits on stresses in FRPs induced at the serviceability limit state. In addition, new stress limits for tendons have been introduced. The design for shear is now an adaptation of this Code’s method for concrete structures and accounts for the decrease in shear carried by the concrete in FRP-reinforced beams. There are also modified provisions for barrier walls.

Funding for developing and publishing this Code was provided by the governments of Alberta, British Columbia, Manitoba, New Brunswick, Newfoundland and Labrador, the Northwest Territories, Nova Scotia, Nunavut, Ontario, Prince Edward Island, Québec, Saskatchewan, and Yukon, Public Works and Government Services Canada, and the Federal Bridge Corporation Limited. This Code could not have been developed without the cooperation of all of these sponsors.

This Code was prepared by the Technical Committee on the Canadian Highway Bridge Design Code, under the jurisdiction of the Strategic Steering Committee on Structures (Design), and has been formally approved by the Technical Committee. It has been approved as a National Standard of Canada by the Standards Council of Canada.

November 2006

Notes: (1) Use of the singular does not exclude the plural (and vice versa) when the sense allows.(2) Although the intended primary application of this Code is stated in Clause 1.1.1, it is important to note that it remains

the responsibility of the users of the Code to judge its suitability for their particular purpose.(3) This publication was developed by consensus, which is defined by CSA Policy governing standardization — Code of

good practice for standardization as “substantial agreement. Consensus implies much more than a simple majority, but not necessarily unanimity”. It is consistent with this definition that a member may be included in the Technical Committee list and yet not be in full agreement with all clauses of this publication.

(4) CSA Codes and Standards are subject to periodic review, and suggestions for their improvement will be referred to the appropriate committee.

(5) All enquiries regarding this Code, including requests for interpretation, should be addressed to Canadian Standards Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6. Requests for interpretation should

(a) define the problem, making reference to the specific clause, and, where appropriate, include an illustrative sketch;(b) provide an explanation of circumstances surrounding the actual field condition; and(c) be phrased where possible to permit a specific “yes” or “no” answer.Committee interpretations are processed in accordance with the CSA Directives and guidelines governing

standardization and are published in CSA’s periodical Info Update, which is available on the CSA Web site at www.csa.ca.

Single user license only. S

torage, distribution or use on network prohibited.

Page 160: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 lv

Foreword

In Canada, the legal mandate for establishing design and construction requirements for highways, including highway bridges, lies with the provincial and territorial governments. Before the publication of the previous edition of this Code, Ontario regulated the design and construction of highway bridges through the Ontario Highway Bridge Design Code. All of the other provinces and territories used CAN/CSA-S6, Design of Highway Bridges, with the exception of Manitoba, which adopted the bridge code published by the American Association of State Highway and Transportation Officials (AASHTO). The previous edition of the Canadian Highway Bridge Design Code was developed to provide a state-of-the-art model design code that could be adopted by all provinces and territories. This new edition is intended to serve the same purpose.

Among the benefits associated with undertaking the development of this Code is the opportunity to establish safety and reliability levels for highway bridges that are consistent across all Canadian jurisdictions. Adoption of a single code makes it easier for the consulting and producer industries to respond to calls for proposals and eliminates the need for familiarity with the details of several codes. The adoption of a single code also supports the implementation of a national highway transportation system with agreed minimum standards and loadings for bridges on interprovincial highways, thereby encouraging consistency of vehicle weights across jurisdictions and supporting the objective of more cost-effective transportation of goods.

Designers need to be aware, however, that although this Code establishes CL-625 loading as the minimum for bridges that are part of the national highway system, it is within the mandate of the provinces and territories to adopt a heavier or lighter live loading based on local traffic conditions. For example, Ontario requires (as specified in Annex A3.4) the use of a CL-625-ONT loading in the design of new bridges; this reflects the higher average regulatory and observed loads for trucks operating in the province. All of the requirements of this Code applicable to CL-W loading also apply to CL-625-ONT loading. Designers should always obtain approval from the regulatory authority when a live loading other than the CL-625 loading is to be used for design, and should check whether any variations from the requirements of this Code are in effect in the jurisdiction, e.g., for evaluation of existing bridges or issuance of overload permits.

This Code was developed by taking into account the different regulatory structures and standards of Canada’s provinces and territories. Overall priorities and objectives were established by the Regulatory Authority Committee (RAC), which also monitored the progress of the Code’s development. In accordance with CSA procedural requirements, however, responsibility for the technical content of this Code was assigned to the Technical Committee (TC), as were decisions on how to deal with the priorities and objectives identified by the RAC. Because of the breadth and complexity of this Code, subcommittees (which were required to operate and report on a consensus basis) were established to oversee each section. In addition, task forces were established to handle specific aspects of this Code. The subcommittees and task forces reported to the TC through their Chairs. The extensive use of subcommittees permitted the recruitment of experts with the knowledge needed to address the sometimes highly specialized subjects covered by this Code.

The developers of this Code wish to acknowledge the contributions of the following individuals, who were unable to complete their terms on the RAC and TC: Ismail Elkholy (RAC and former Vice-Chair of TC) (Manitoba Department of Highways and Transportation) and Peter Lester (RAC and TC) (Newfoundland and Labrador Department of Transportation and Works).

This Code is complemented by CSA S6.1-06, Commentary on CAN/CSA-S6-06, Canadian Highway Bridge Design Code, which provides rationale statements and explanatory material for many of the clauses of this Code. Although this Code is being published in both English and French, CSA S6.1 is available only in English.

Single user license only. S

torage, distribution or use on network prohibited.

Page 161: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

Single user license only. S

torage, distribution or use on network prohibited.

Page 162: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 1

Section 1 — General

1.1 Scope 21.1.1 Scope of Code 21.1.2 Scope of this Section 21.1.3 Terminology 21.2 Reference publications 21.3 Definitions 101.3.1 General 101.3.2 General administrative definitions 101.3.3 General technical definitions 101.3.4 Hydraulic definitions 151.4 General requirements 161.4.1 Approval 161.4.2 Design 171.4.3 Evaluation and rehabilitation of existing bridges 181.4.4 Construction 181.5 Geometry 201.5.1 Planning 201.5.2 Structure geometry 201.6 Barriers 201.6.1 Superstructure barriers 201.6.2 Roadside substructure barriers 201.6.3 Structure protection in waterways 211.6.4 Structure protection at railways 211.7 Auxiliary components 211.7.1 Expansion joints and bearings 211.7.2 Approach slabs 211.7.3 Utilities on bridges 211.8 Durability and maintenance 221.8.1 Durability and protection 221.8.2 Bridge deck drainage 221.8.3 Maintenance 241.9 Hydraulic design 251.9.1 Design criteria 251.9.2 Investigations 261.9.3 Location and alignment 261.9.4 Estimation of scour 261.9.5 Protection against scour 271.9.6 Backwater 291.9.7 Soffit elevation 291.9.8 Approach grade elevation 301.9.9 Channel erosion control 301.9.10 Stream stabilization works and realignment 311.9.11 Culverts 31

Single user license only. S

torage, distribution or use on network prohibited.

Page 163: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

2 November 2006

Section 1General

1.1 Scope

1.1.1 Scope of CodeThis Code applies to the design, evaluation, and structural rehabilitation design of fixed and movable highway bridges in Canada. There is no limit on span length, but this Code does not necessarily cover all aspects of design for every type of long-span bridge. This Code also covers the design of pedestrian bridges, retaining walls, barriers, and highway accessory supports of a structural nature, e.g., lighting poles and sign support structures.

This Code is not intended to apply to public utility structures or to bridges used solely for railway or rail transit purposes.

This Code also does not specify requirements related to coastal effects (e.g., exposure to sea action and icebergs) or to mountainous terrain effects (e.g., avalanches). For structures that can be subject to such effects, specialists need to be retained to review and advise on the design and to ensure that the applicable requirements of other codes are met.

For bridges not entirely within the scope of this Code, the requirements of this Code apply only when appropriate. Necessary additional or alternative design criteria are subject to Approval.

1.1.2 Scope of this SectionThis Section specifies requirements for applying the Code and requirements of a general nature for bridges, culverts, and related works. These requirements govern basic geometry and hydraulic design. General requirements are also specified for subsidiary components, deck drainage, maintenance, and inspection access. Broad guidelines related to economic, aesthetic, and environmental considerations are also provided.

1.1.3 TerminologyIn CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

1.2 Reference publicationsThis Code refers to the following publications, and where such reference is made, it shall be to the edition listed below, including all amendments published thereto.

CSA (Canadian Standards Association)CAN/CSA-A23.1-04/CAN/CSA-A23.2-04Concrete materials and methods of concrete construction/Methods of test and standard practices for concrete

Single user license only. S

torage, distribution or use on network prohibited.

Page 164: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 3

CAN/CSA-A23.4-00/CAN/CSA-A251-00Precast concrete — Materials and construction/Qualification code for architectural and structural precast concrete products

CAN/CSA-A257 Series-03Standards for concrete pipe and manhole sections

CAN/CSA-A257.1-03Non-reinforced circular concrete culvert, storm drain, sewer pipe, and fittings

CAN/CSA-A257.2-03Reinforced circular concrete culvert, storm drain, sewer pipe, and fittings

CAN/CSA-A257.3-03Joints for circular concrete sewer and culvert pipe, manhole sections, and fittings using rubber gaskets

B95-1962 (R2002)Surface texture (roughness, waviness and lay)

B97.3-M1982 (R2002)Tolerances and standard fits for mating parts, metric sizes

B111-1974 (R2003)Wire nails, spikes and staples

C22.1-06Canadian Electrical Code, Part I

C22.2 No. 100-04Motors and generators

C22.2 No. 178-1978 (R2001)Automatic transfer switches

CAN/CSA-C22.3 No. 1-01Overhead systems

G4-00Steel wire rope for general purpose and for mine hoisting and mine haulage

G30.3-M1983 (withdrawn)Cold-drawn steel wire for concrete reinforcement

G30.5-M1983 (withdrawn)Welded steel wire fabric for concrete reinforcement

G30.14-M1983 (withdrawn)Deformed steel wire for concrete reinforcement

G30.15-M1983 (withdrawn)Welded deformed steel wire fabric for concrete reinforcement

CAN/CSA-G30.18-M92 (R2002)Billet-steel bars for concrete reinforcement

Single user license only. S

torage, distribution or use on network prohibited.

Page 165: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

4 November 2006

G40.20-04/G40.21-04General requirements for rolled or welded structural quality steel/Structural quality steel

CAN/CSA-G164-M92 (R2003)Hot dip galvanizing of irregularly shaped articles

G189-1966 (R2003)Sprayed metal coatings for atmospheric corrosion protection

G279-M1982 (withdrawn)Steel for prestressed concrete tendons

G401-01Corrugated steel pipe products

CAN3-O56-M79 (R2001)Round wood piles

O80 Series-97 (R2002)Wood preservation

O80.3-97Preservative treatment of piles by pressure processes

O80.9-97Preservative treatment of plywood by pressure processes

CAN/CSA-O86-01Engineering design in wood

O122-06Structural glued-laminated timber

O141-05Softwood lumber

O177-06Qualification code for manufacturers of structural glued-laminated timber

S6.1-06Commentary on CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S16-01Limit states design of steel structures

S157-05/S157.1-05Strength design in aluminum/Commentary on CSA S157-05, Strength design in aluminum

S269.1-1975 (R2003)Falsework for construction purposes

CAN/CSA-S269.2-M87 (R2003)Access scaffolding for construction purposes

Single user license only. S

torage, distribution or use on network prohibited.

Page 166: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 5

CAN/CSA-S806-02Design and construction of building components with fibre-reinforced polymers

W47.1-03Certification of companies for fusion welding of steel

CAN/CSA-W48-01Filler materials and allied materials for metal arc welding

W59-03Welded steel construction (metal arc welding)

W178.2-01Certification of welding inspectors

W186-M1990 (R2002)Welding of reinforcing bars in reinforced concrete construction

AASHTO (American Association of State Highway and Transportation Officials)Guide Specifications for Bridge Railings (1989) (withdrawn)

GVCB-1 (1991)Guide Specification and Commentary for Vessel Collision Design of Highway Bridges

HB-17 (2002)Standard Specifications for Highway Bridges, 17th ed.

ANSI/NEMA (American National Standards Institute/National Electrical Manufacturers Association)MG-1-2003Motors and generators

AREMA (American Railway Engineering and Maintenance of Way Association)Manual for Railway Engineering, 4th ed. (2005)

ASCE (American Society of Civil Engineers)15-98Standard Practice for Direct Design of Buried Precast Concrete Pipe Using Standard Installations (SIDD)

ASME International (American Society of Mechanical Engineers)B1.10M-2004Unified Miniature Screw Threads

B4.1-1967 (R2004)Preferred Limits and Fits for Cylindrical Parts

B17.1-1967 (R2003)Keys and Keyseats

B18.3-2003Socket Cap, Shoulder, and Set Screws, Hex and Spline Keys (Inch Series)

Single user license only. S

torage, distribution or use on network prohibited.

Page 167: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

6 November 2006

ASTM International (American Society for Testing and Materials)A 27/A 27M-05Standard Specification for Steel Castings, Carbon, for General Application

A 36/A 36M-05Standard Specification for Carbon Structural Steel

A 48/A 48M-03Standard Specification for Gray Iron Castings

A 53/A 53M-04aStandard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless

A 108-03 e1Standard Specification for Steel Bar, Carbon and Alloy, Cold-Finished

A 148/148M-05Standard Specification for Steel Castings, High Strength, for Structural Purposes

A 153/A 153M-05Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware

A167-99 (2004)Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip

A 240/A 240M-05Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications

A 276-05Standard Specification for Stainless Steel Bars and Shapes

A 307-04Standard Specification for Carbon Steel Bolts and Studs, 60 000 PSI Tensile Strength

A 325-04bStandard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength

A 325M-04bStandard Specification for Structural Bolts, Steel, Heat Treated 830 MPa Minimum Tensile Strength [Metric]

A 370-05Standard Test Methods and Definitions for Mechanical Testing of Steel Products

A 449-04bStandard Specification for Quenched and Tempered Steel Bolts and Studs

A 486/A 486M-84 (withdrawn Standard)Specification for Steel Castings for Highway Bridges

A 490-04aStandard Specification for Structural Bolts, Alloy Steel, Heat Treated, 150 ksi Minimum Tensile Strength

Single user license only. S

torage, distribution or use on network prohibited.

Page 168: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 7

A 490M-04aStandard Specification for High-Strength Steel Bolts, Classes 10.9 and 10.9.3, for Structural Steel Joints [Metric]

A 510-03Standard Specification for General Requirements for Wire Rods and Coarse Round Wire, Carbon Steel

A 586-04aStandard Specification for Zinc-Coated Parallel and Helical Steel Wire Structural Strand

A 603-98 (R2003)Standard Specification for Zinc-Coated Steel Structural Wire Rope

A 641/A 641M-03Standard Specification for Zinc-Coated (Galvanized) Carbon Steel Wire

A 653/A 653M-05Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

A 668/A 668M-04Standard Specification for Steel Forgings, Carbon and Alloy, for General Industrial Use

A 675/A 675M-03 e1Standard Specification for Steel Bars, Carbon, Hot-Wrought, Special Quality, Mechanical Properties

A 709/A 709M-05Standard Specification for Carbon and High-Strength Low-Alloy Structural Steel Shapes, Plates, and Bars and Quenched-and-Tempered Alloy Structural Steel Plates for Bridges

B 22-02Standard Specification for Bronze Castings for Bridges and Turntables

B 36/B 36M-01Standard Specification for Brass Plate, Sheet, Strip, and Rolled Bar

B 121/B 121M-01Standard Specification for Leaded Brass Plate, Sheet, Strip, and Rolled Bar

B 746/B 746M-02Standard Specification for Corrugated Aluminum Alloy Structural Plate for Field-Bolted Pipe, Pipe-Arches, and Arches

C 506M-05Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe [Metric]

C 507M-05Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe [Metric]

C 567-05Standard Test Method for Determining Density of Structural Lightweight Concrete

C 1399-04Test Method for Obtaining Average Residual-Strength of Fiber-Reinforced Concrete

Single user license only. S

torage, distribution or use on network prohibited.

Page 169: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

8 November 2006

C 1433-04 e1Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers [Metric]

D 395-03Standard Test Methods for Rubber Property — Compression Set

D 412-98a (2002) e1Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers — Tension

D 429-03Standard Test Methods for Rubber Property — Adhesion to Rigid Substrates

D 573-04Standard Test Method for Rubber — Deterioration in an Air Oven

D 698-00 ae1Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Standard Effort (12,400 ft-lbf/ft3 (600 kN-m/m3))

D 746-04Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact

D 1149-99Standard Test Method for Rubber Deterioration-Surface Ozone Cracking in a Chamber

D 1557-02 e1Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56,000 ft-lbf/ft3 (2,700 kN-m/m3))

D 2239-03Standard Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter

D 2240-04 e1Standard Test Method for Rubber Property — Durometer Hardness

D 2487-00Standard Classification of Soils for Engineering Purposes (Unified Soil Classification System)

D 3350-04Standard Specification for Polyethylene Plastics Pipe and Fittings Materials

D 4541-02Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers

D 4894-04Standard Specification for Polytetrafluoroethylene (PTFE) Granular Molding and Ram Extrusion Materials

D 5456-05Standard Specification for Evaluation of Structural Composite Lumber Products

F 436-04Standard Specification for Hardened Steel Washers

Single user license only. S

torage, distribution or use on network prohibited.

Page 170: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 9

F 568M-04Standard Specification for Carbon and Alloy Steel Externally Threaded Metric Fasteners

PS 62-97 (withdrawn Provisional Standard)Provisional Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers

AWPA (American Wood-Preservers’ Association)C33-03Standard for Preservative Treatment of Structural Composite Lumber by Pressure Processes

Government of CanadaNavigable Waters Protection Act, RSC 1985, c. N-22

NCHRP (National Cooperative Highway Research Program)Report 230 (1980)Recommended Procedures for the Safety Performance Evaluation of Highway Appurtenances

Report 350 (1993)Recommended Procedures for the Safety Performance Evaluation of Highway Features

NEMA (National Electrical Manufacturers Association)ICS9-1993 (withdrawn Standard)Industrial Control and Systems: Power Circuit Accessories

NLGA (National Lumber Grades Authority)Standard Grading Rules for Canadian Lumber (2003)

NRCC (National Research Council Canada)National Building Code of Canada, 2005

National Fire Code of Canada, 2005

Research Council on Structural ConnectionsSpecification for Structural Joints Using ASTM A325 or A490 Bolts (2004)

Transportation Association of CanadaGeometric Design Guide for Canadian Roads (1999)

Guide to Bridge Hydraulics, 2nd ed. (2001)

Manual of Uniform Traffic Control Devices for Canada (1998)

UL (Underwriters Laboratories Inc.)845 (1995)Standard for Motor Control Centers

U.S. Department of DefenseMIL-S-8660C (1999) (cancelled Specification)Silicone Compound

Single user license only. S

torage, distribution or use on network prohibited.

Page 171: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

10 November 2006

1.3 Definitions

1.3.1 GeneralThe definitions in Clauses 1.3.2 to 1.3.4 apply in this Code.Note: Additional definitions are found in Sections 2 to 16. In the case of a conflict between a definition in Sections 2 to 16 and a definition in Clauses 1.3.2 to 1.3.4, the definition in Sections 2 to 16 takes precedence.

1.3.2 General administrative definitionsNote: The general administrative terms defined in this Clause are capitalized wherever they are used in this Code in their defined sense.

Approval or Approved — approval, or approved, in writing by the Regulatory Authority.

Checker — a member or licensee of the Engineering Association who carries out the design check, rehabilitation design check, or evaluation check of a bridge or structure.

Construction — the construction, reconstruction, rehabilitation, repair, or demolition of a structure.

Constructor — (a) a Person that contracts to perform all of the Construction work on a project;(b) an Owner that contracts with two or more Persons for such Persons to perform part of the

Construction work on a project; or(c) an Owner that performs all or part of the Construction work on a project.

Engineer — a member or licensee of the Engineering Association who carries out the design, rehabilitation design, or evaluation of a bridge or structure.

Engineering Association — an organization authorized by charter to regulate the profession of engineering in a province or territory.

Owner — the Person having responsibility for and control of a bridge or structure.

Person — an individual, board, commission, partnership, or corporation (including a municipal corporation) and his, her, or its agents, successors, and assignees.

Plans — the drawings, documents, and specifications that define a Construction project, form part of the contract documents, or are included in the contract documents by reference; all Approved drawings and descriptions produced by a Constructor for the Construction of a bridge or other structure; and all revisions to the items described in this definition.

Regulatory Authority — the federal, provincial, or territorial Minister having governmental jurisdiction and control, his or her nominee, or the local authority to whom this authority is delegated.

1.3.3 General technical definitions

Abutment — a substructure that supports the end of a superstructure and retains some or all of the bridge approach fill.

Arterial road — an arterial road as defined in the Transportation Association of Canada’s Geometric Design Guide for Canadian Roads.

Auxiliary component — a component of a structural system that does not constitute part of the intended load-sharing system. Auxiliary components include expansion joints, approach slabs, railings and barriers, and deck drains.

Average annual daily traffic — the total volume of traffic during a year divided by the number of days in the year.

Single user license only. S

torage, distribution or use on network prohibited.

Page 172: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 11

Average daily traffic — the total volume of traffic during a given time period, in whole days, greater than one day and less than one year, divided by the number of days in that time period.

Average daily truck traffic — the total volume of truck traffic during a given time period, in whole days, greater than one day and less than one year, divided by the number of days in that time period.

Ballast wall — that part of an abutment above the bearing seats used primarily to retain approach fill and to provide a support for an approach slab and expansion joint.

Barrier — a wall, railing, or fence that serves as a vehicular, pedestrian, bicycle, or combination barrier or as a noise or privacy barrier.

Barrier wall — a barrier that has no openings and is at least 800 mm high.

Bearing — a structural device that transmits loads while facilitating translation or rotation.

Bevelled end — a culvert end cut or formed to lie in a plane inclined to the vertical.

Bicycle barrier — a barrier for confining cyclists.

Box culvert — a closed-invert culvert with a monolithic rectangular or trapezoidal cross-section.

Bridge — a structure that provides a roadway or walkway for the passage of vehicles, pedestrians, or cyclists across an obstruction, gap, or facility and is greater than 3 m in span.

Clear recovery zone — a roadside area that can be safely used by errant vehicles, is immediately adjacent to the edge of a traffic lane, and is clear of hazards.

Coated reinforcement — steel reinforcement that is used in concrete and is coated with a protective coating complying with the requirements of Section 8.

Collapse — a major change in the geometry of a structure rendering it unfit for use.

Collector — a collector road as defined in the Transportation Association of Canada’s Geometric Design Guide for Canadian Roads.

Combination barrier — a barrier that serves as a vehicular barrier and as a pedestrian or bicycle barrier.

Component — a member of a structure requiring individual design consideration.

Crossfall — the transverse slope of a roadway, sidewalk, or deck surface.

Crown —

Crown of a bridge or culvert — the highest point on a curved soffit.

Crown of a roadway — the highest point of a cross-section, formed where opposite crossfalls meet.

Culvert — a structure that forms an opening through soil.

Curb — a raised surface beside a roadway, forming a vertical or nearly vertical face that delineates the roadway edge and in some cases also channels water.

Cut-off wall — a vertical wall attached to and extending below the end of a culvert or other structure.

Deck — a component of a bridge superstructure that carries and distributes wheel loads.

Deck joint — a structural discontinuity between two components, at least one of which is a deck component, that permits relative rotation or translation between the two.

Single user license only. S

torage, distribution or use on network prohibited.

Page 173: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

12 November 2006

Deck slab — a solid concrete slab that carries and distributes loads to supporting members.

Deck width — the horizontal distance, measured at deck level perpendicular to the direction of travel, from face to face of sidewalks or curbs (or barrier walls if there are no curbs).

Design — the process of planning, analyzing, proportioning, drawing, and writing specifications for the Construction of a structure.

Design lane — a longitudinal strip that is a fraction of the deck width, within which a truck or lane load is placed for the purpose of design or evaluation.

Design life — a period of time, specified by an Owner, during which a structure is intended to remain in service.

Divided highway — a highway with two or more roadways separated by medians or barriers.

Downpipe — a pipe for conveying water from a deck drain to the ground or to a storm sewer.

Downspout — a short pipe extending from a deck drain to below the bridge superstructure.

Drip groove — a groove formed in a surface and intended to cause water to drop off the surface rather than run along it.

Ductility — the ability to deform without failing after yielding.

Evaluation — the process of determining load-carrying capacity.

Expressway — an expressway as defined in the Transportation Association of Canada’s Geometric Design Guide for Canadian Roads.

Factored resistance — the resistance of a component, connection, foundation, or cross-section calculated in accordance with the requirements and assumptions of this Code, including the application of appropriate resistance factors.

Failure — a state in which rupture, severe distortion or displacement, or loss of strength has occurred as a result of the load-carrying capacity of a component or connection having been exceeded.

Falsework — a temporary structure that is used to support another structure or a part thereof, usually during a particular Construction procedure or sequence.

Fascia — the surface that forms the lateral limit of a bridge.

Fatigue — the initiation or propagation of cracks caused by the repeated application of load.

Fatigue limit state — a limit state at which the effects of fatigue on the strength or condition of a structure are considered.

Floor beam — a transverse beam spanning between longitudinal girders, trusses, or arches.

Freeway — a freeway as defined in the Transportation Association of Canada’s Geometric Design Guide for Canadian Roads.

Gabion — a wire mesh basket that is filled with stone or broken rock or concrete and forms part of a larger unit used for slope stability, erosion control, or related purposes.

Girder — a longitudinal beam resting directly on the substructure.

Guiderail — a rail system along the edge of a roadway to delineate the roadway edge and to help redirect errant vehicles.

Single user license only. S

torage, distribution or use on network prohibited.

Page 174: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 13

Hazard — any obstacle or other feature, e.g., an embankment, sideslope, or body of water deeper than 1 m, that, without protection, is likely to cause significant injury to the occupants of a vehicle striking it.

Headwall — a transverse wall at the end of a culvert.

Highway — a common and public thoroughfare, e.g., a road, street, avenue, parkway, driveway, square, place, bridge, culvert, viaduct, or trestle, designed and intended for, or used by the general public for, the passage of pedestrians, cyclists, animals, or vehicles.

Highway class — the class of highway determined in accordance with the volume of vehicular and truck traffic (see Clause 1.4.2.2).

Highway classification — a category of highway, i.e., freeway, arterial road, collector road, or local road, that is used in establishing criteria for the geometric design of bridges.

Interface shear — shear at and in the plane of an interface between (a) dissimilar elements or materials, e.g., a deck slab and a beam, or a web and a flange; or (b) concrete cast at different times.

Lane — a traffic lane.

Limit states — those conditions beyond which a structure or component ceases to meet the criteria for which it was designed.

Load effect — any effect on or response of a structural component due to loads, forces, imposed deformations, or volumetric changes.

Load factor — a factor applied to loads to take into account variability of loads, lack of precision in analysis for load effects, and reduced probability of loads from different sources acting simultaneously.

Local road — a local road as defined in the Transportation Association of Canada’s Geometric Design Guide for Canadian Roads.

Longitudinal — the lengthwise direction. For bridges, this is normally the direction of traffic flow on the deck and of the main span. For culverts, it is normally the direction of the culvert axis.

Long-span bridge — a bridge with an individual span longer than 150 m.

Median — a raised or marked area that separates the roadways of a divided highway.

Member — an element or assembly of elements within a structure that performs an identifiable function and can require individual design consideration.

Multiple-load-path structure — a system of components in which the failure of any primary component or connection will not cause the structure to collapse.

Open-type abutment — an abutment in front of which is a slope extending downward from a point on the abutment face that is just below the superstructure.

Orthotropic deck — a deck that is orthogonally anisotropic. Normally this is a deck made of steel plate stiffened with open or closed steel ribs welded to the underside of the steel plate.

Pedestrian barrier — a barrier that is intended to confine pedestrians.

Pedestrian bridge — a bridge that provides a walkway primarily for the passage of pedestrians.

Pier — a substructure used to transfer superstructure loads from the spans it supports to the foundation.

Single user license only. S

torage, distribution or use on network prohibited.

Page 175: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

14 November 2006

Primary component — a component of a structural system that performs an essential role in load transfer and, on becoming ineffective, will substantially reduce the load-carrying capacity of the system or cause the collapse of a single-load-path structure.

Rehabilitation — a modification, alteration, or improvement of the condition of a structure or bridge subsystem that is designed to correct deficiencies in order to achieve a particular design life and live load level.

Reliability index or safety index — a numerical measure of the reliability of structures or components.

Resistance factor — a factor applied to the unfactored resistance of a component or material at the ultimate limit state to take into account the variability of material properties and dimensions, quality of work, type of failure, and uncertainty in the prediction of the resistance.

Return period — the average period in years between the occurrence of an event (e.g., a flood) and the next occurrence of an event of the same type.

Roadway — that part of a highway that is intended for or can be used by vehicles, including traffic lanes, shoulders, and other adjacent areas such as those provided for clearance, pedestrians, or bicycles, if these areas are not separated by a barrier, by a guiderail, or by a curb that is at least 150 mm high.

Secondary component — a component of a structural system that does not have an essential role in load transfer and whose removal from the structure would result in at most a minor redistribution of load effects to adjacent components.

Serviceability limit state — the limit state at which the effects of vibration, permanent deformation, and cracking on the usability or condition of a structure are considered.

Sidewalk — a pedestrian walkway located beside a roadway.

Single-load-path structure — a structure in which the failure of any primary component or connection will cause the structure to collapse.

Skew angle — the angle by which a bridge differs from a right-angled crossing. Normally, this is the angle between the longitudinal centreline of the bridge and a line perpendicular to the centreline of the bearings.

Span — the following distances:(a) the horizontal distance between the centrelines of adjacent piers or abutments; (b) where bearings are provided, the horizontal distance between bearing centrelines;(c) for rigid frames, including box culverts, the clear opening width; and(d) a distance specified as a span in another Section of this Code.

Spread footing — a footing that transfers structure loads directly to the underlying soil, rock, or engineered fill.

Stress range — the algebraic difference between the maximum and minimum stress at the fatigue limit state where tension and compression are of opposite sign.

Stringer — a longitudinal element supporting the deck and spanning between floor beams.

Substructure — that part of a bridge, including abutments and piers, that supports the superstructure.

Superstructure — that part of a bridge that spans water, a roadway, a railway, or another obstruction and is supported by the substructure.

Temporary structure — a structure with a design life of less than five years.

Traffic barrier — a barrier that is intended to confine vehicular traffic to a roadway or bridge deck.

Single user license only. S

torage, distribution or use on network prohibited.

Page 176: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 15

Traffic lane — a part of a roadway designated for the movement of a single file of vehicles.

Transverse — in a plane that is perpendicular to the longitudinal direction.

Ultimate limit state — a limit state that involves failure (including rupture, fracture, overturning, sliding, and other instability).

Unfactored resistance — the resistance of a component or connection based on specified material properties and nominal dimensions and calculated in accordance with this Code.

Utilities — transmission and distribution lines, pipes, cables, and other associated equipment used for public services including, but not limited to, electric power transmission and distribution, lighting, heating, gas, oil, water, sewage, cable television, telephone, and telegraph facilities.

Vehicle — a motor vehicle, motor-assisted bicycle, trailer, traction engine, car, truck, farm tractor, road-building machine, or any device drawn or propelled by power other than that of the driver or operator, but not including the cars or engines of electric, diesel, or steam railways.

Yield strength — the specified or established minimum yield strength of a material.

1.3.4 Hydraulic definitions

Abnormal flood — a flood or flood condition produced at a site by abnormal events or conditions downstream or upstream of the site, including ice jams.

Apron — an area of protective material laid on a stream bed to control local scour around a feature requiring protection.

Backwater — the rise in water level caused by a downstream obstruction or constriction in a channel.

Bridge waterway — that part of a bridge opening that is or can be occupied by water.

Check flood — a flood greater than the normal design flood, used to check that a waterway designed for the normal design flood will withstand a larger flood without embankment failure or structural collapse.

Collar — a concrete ring or stiffening component placed integrally with and at the end of a metal culvert.

Competent velocity — the velocity at which water will begin to move material of a given type and particle size.

Degradation — general and progressive lowering of the longitudinal profile of a channel by erosion.

Depth of scour — the depth of material removed from a stream bed by scour, measured below the original bed.

Design flood — a flood that a structure is designed to accommodate while conforming to specified requirements.

Discharge — the rate of flow of water in cubic metres per second.

Drop structure — a structure in a channel designed to lower the channel invert and the hydraulic grade line abruptly.

Flood — an event leading to an above-normal water level or discharge.

Flood plain — the relatively level area that adjoins a watercourse or other body of water and is subject to periodic flooding.

Single user license only. S

torage, distribution or use on network prohibited.

Page 177: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

16 November 2006

General scour — scour in a stream bed that occurs at a structure as a result of general stream velocities exceeding the competent velocity of channel bed material.

Improved inlet — a culvert inlet incorporating refined inlet geometry for the purpose of improving the culvert hydraulic capacity.

Inerodible — durable enough to ensure that no important erosion will occur during the design life of the structure.

Invert — the lowest point at a particular section of a channel bed or culvert opening.

Local scour — scour in a stream bed adjacent to an obstruction, e.g., a pier or abutment, resulting from the disruption of flow caused by the obstruction.

Normal design flood — the design flood that a structure is required to accommodate without damage to the structure or approaches.

Normal water level — the average summer water level.

Open-footing culvert — a culvert with individual wall foundations on either side of a stream bed or passageway.

Original stream bed — the bed as it existed or exists before an actual or planned modification or activity.

Piping — a movement of water through the soil around a structure that can cause loss of fine particles.

Regulatory flood — a designated flood primarily used to define the limits of a flood plain for regulatory purposes. In special circumstances, it may be specified as the design flood to be used for particular purposes.

Relief flow — the flood flow that bypasses the main structure opening at a stream or river crossing by flowing over the highway elsewhere or through a relief structure.

Revetment — a vertical or inclined facing of rip-rap or other material protecting a soil surface from erosion.

Scour — erosion of a stream bed by the action of flowing water.

Stream bed — the surface of a natural or modified channel bed.

Ultimate bed elevation — the anticipated lowest stream bed elevation occurring during the design life of a structure that allows for all scour and for degradation and artificial deepening.

1.4 General requirements

1.4.1 ApprovalApproval shall be obtained for any item, component, process, analytical method, or method of construction that does not comply with this Code or is outside Code limits.

Use of load or strength formulations from other codes in conjunction with this Code shall require an Approved investigation of compatibility and comparative safety levels, with appropriate adjustment of load and resistance factors.

Single user license only. S

torage, distribution or use on network prohibited.

Page 178: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 17

1.4.2 Design

1.4.2.1 Design philosophyIn the interpretation and application of this Code, the primary concern shall be the safety of the public, including that of Construction and maintenance workers.

Design shall be based on the consideration of limit states in which, at the ultimate limit state, the factored resistance is used to exceed the total factored load effect. Structural components shall be designed to comply with the ultimate limit state, serviceability limit state, and fatigue limit state requirements of the applicable clauses of this Code. The Engineer shall ensure that all limit states appropriate to the particular structure being designed are investigated.

In accordance with Section 5, and unless otherwise specified, elastic methods of analysis shall be required for determining structural behaviour and for determining responses of a structure and its components at all limit states. Inelastic methods and experimental methods of analysis of bridges shall require Approval unless specifically required or permitted by this Code.

1.4.2.2 Highway classThe highway class shall be determined in accordance with Table 1.1 for the average daily traffic and average daily truck traffic volumes for which the structure is designed.

Unless otherwise Approved, all new bridges shall be designed to comply with Class A highway requirements.

Table 1.1Highway classes

(See Clause 1.4.2.2.)

1.4.2.3 Design lifeUnless otherwise Approved, the design life of new structures shall be 75 years.

1.4.2.4 Structural behaviour and articulationAll joints and bearings shall be designed as part of a system of articulation with appropriate anchorages, guides, restraints, and freedoms.

Where bridges have superstructures that are supported by bearings on piers or abutments or some combination thereof, relative movements between the superstructure and substructure shall be analyzed and shall be allowed for in the design.

The possible effects of the inexact fit of components shall be considered, with normal Construction and fabrication tolerances assumed unless tolerances are specified on the Plans.

The effects of deflection on the magnitude and position of bearing reactions shall be considered, with allowance for the approximate nature of deflection calculations.

Where relative movements are restrained or limited, the resulting force effects and distortions shall be considered.

Highway class

Average daily traffic (ADT) per lane(number of vehicles)

Average daily truck traffic (ADTT) per lane(number of vehicles)

A > 4000 > 1000

B > 1000–4000 > 250–1000

C 100–1000 50–250

D < 100 < 50

Single user license only. S

torage, distribution or use on network prohibited.

Page 179: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

18 November 2006

Unless otherwise Approved, superstructures with bearings and joints that electrically insulate them from the substructure and ground shall have direct ground connections to ensure that stray electrical and atmospheric electrostatic charges are harmlessly conducted to earth.

1.4.2.5 Single-load-path structuresSpecial consideration shall be given to the critical components of single-load-path structures. Sufficient additional strength and protection shall be provided to ensure that they will not fail.

1.4.2.6 EconomicsAfter safety, the total projected lifetime cost shall be the determining consideration in selecting the type of structure, configuration of spans and supports, and Construction materials. This cost shall include allowances for inspection, maintenance, repair, and rehabilitation throughout the design life of the structure.

1.4.2.7 EnvironmentBridges, culverts, and their associated works shall be designed to comply with all environmental requirements established for the site. Wherever possible, features of archaeological, historical, and cultural importance shall be preserved.

The design shall include an assessment of possible environmental effects and measures for limiting adverse effects to a practical minimum.

Particular attention shall be paid to the preservation of wildlife and plant habitat. Structures on fish-bearing streams shall be designed to pass fish in accordance with Approved methods and criteria.

1.4.2.8 AestheticsIn the design and rehabilitation of structures, consideration shall be given to the appearance of the finished structure and to its compatibility with its surroundings. Wherever possible, the appearance of a structure shall be such that it will be generally perceived as an enhancement to its surroundings.

Structures shall be simple and graceful in form, shall intrude minimally on desirable scenery, and shall exhibit an integrity in which the function of components is explicit in their form and their size realistically reflects necessary strength. Visual discontinuities or abrupt changes shall be avoided.

Embellishments shall be permitted only where an important purpose is served and when the cost is demonstrably justified by the end served.

1.4.3 Evaluation and rehabilitation of existing bridges

1.4.3.1 EvaluationRequirements for the evaluation and load testing of highway bridges are specified in Section 14. The requirements of all other Sections shall be applied as appropriate unless specifically modified by Section 14.

1.4.3.2 Rehabilitation designProvisions for the rehabilitation design of highway bridges are specified in Section 15. The requirements of all other Sections shall be applied as appropriate unless specifically modified by Section 14 or 15.

1.4.4 Construction

1.4.4.1 GeneralFor the design of new bridges and the rehabilitation design of existing bridges, the appropriate Sections of this Code shall apply to the consideration of all stages of Construction.

In the evaluation of strength and stability for all stages, the following shall be considered:(a) the intended sequence of Construction;(b) the absence of restraints that would be present in the completed structure;

Single user license only. S

torage, distribution or use on network prohibited.

Page 180: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

© Canadian Standards Association Canadian Highway Bridge Design Code

November 2006 19

(c) the possibility of loads or stresses in a member or component being temporarily greater than or of a reverse nature to those after completion;

(d) construction loads; and(e) the consequences of failure.

1.4.4.2 Construction safetyProtection for workers and the public at the construction site shall be in accordance with the applicable health and safety Acts and regulations. In the selection of construction methods and types of structures, the safety of construction workers shall be considered.

1.4.4.3 Construction methodsWhen a bridge cannot be constructed without new or unusual procedures, or the assumed method of construction is not obvious, at least one method of construction shall be indicated on the Plans.

When the method of Construction, rehabilitation, or demolition as envisaged by the Engineer is of such a nature as to cause critical load effects during Construction, the sequence of Construction stages and all necessary temporary support systems shall be shown on the Plans.

The Plans shall indicate the location of all necessary temporary roadway and railway protection.The Plans shall require that when deviations from the indicated Construction methods are proposed,

the Constructor shall submit new Plans to the Owner for Approval. The new Plans shall be signed and sealed in accordance with the requirements of the Regulatory Authority and indicate all proposed methods of Construction, sequences of Construction, and temporary support systems.

1.4.4.4 Temporary structuresThis Code shall apply to all temporary structures, except as follows:(a) CSA S269.1 and CAN/CSA-S269.2 shall apply to the design of falsework and temporary access

scaffolding.(b) The requirements of the Regulatory Authority shall apply in lieu of this Code’s requirements for

durability and serviceability.(c) This Code shall not apply to temporary traffic barrier installations.

Except where otherwise Approved, falsework and temporary access scaffolding plans shall be designed by an Engineer and independently checked.

1.4.4.5 PlansThe Plans shall specify all necessary details of the bridge or structure, the material requirements, the classification of the highway, the design live load, the rehabilitation level (where applicable), and the year of publication and edition number of the edition of this Code used.

The system of articulation shall be shown on the Plans, including the location and type of bearings. Jacking locations shall be shown as required by Clause 1.8.3.3.

Signing and sealing of drawings shall be performed in accordance with the requirements of the Regulatory Authority.

The Plans shall include Approved specifications that are detailed and comprehensive enough to ensure that Construction is carried out in the manner and to the standards assumed in design and implicit in this Code.

The requirements of this Code directly requiring the compliance of the Constructor shall be incorporated into the specifications.

1.4.4.6 Quality control and assuranceContractual requirements, Construction supervision, inspection, and testing shall be such as to ensure compliance with the Plans.

Single user license only. S

torage, distribution or use on network prohibited.

Page 181: 10.10.2.2 Laterally supported members - Goodfellow Inc-S6S1-10-PARTIE-2.pdf · ©Canadian Standards Association Supplement No. 1 to CAN/CSA-S6-06, Canadian Highway Bridge Design Code

CAN/CSA-S6-06 © Canadian Standards Association

20 November 2006

1.5 Geometry

1.5.1 PlanningThe much greater cost and increased difficulty of widening bridges as compared to roadways shall be considered in determining whether the bridge cross-section should suit that of the proposed roadway or that planned for the roadway at some time in the future.

Site conditions and requirements shall be considered in developing bridge alignment and plan geometry to accommodate existing and future traffic.

The design average annual daily traffic, design hourly volume, and directional split shall be those forecast for a period starting not less than ten years after the design life start. For structures that are not easily widened, a longer period shall be determined from an economic assessment.

Preference shall be given to straight horizontal alignments for bridges. The bridge deck longitudinal profile shall be continuous with the approach road profile.

1.5.2 Structure geometry

1.5.2.1 GeneralRoadway and sidewalk widths, curb widths and heights, and all other geometrical requirements not specified in this Code shall comply with the standards of the Regulatory Authority or, in their absence, with the Transportation Association of Canada’s Geometric Design Guide for Canadian Roads.

Sidewalks and bicycle paths shall be separated from traffic lanes by a barrier or guiderail, or by a curb with a face height of at least 150 mm and a face slope not flatter than 1 horizontal to 3 vertical. Sidewalks and bicycle paths not so separated shall be designed as part of the roadway.

1.5.2.2 Clearances

1.5.2.2.1 Roadways and sidewalksRoadway and sidewalk clearances for structure openings and on structures shall comply with the standards of the Regulatory Authority or, in their absence, with the Transportation Association of Canada’s Geometric Design Guide for Canadian Roads.

1.5.2.2.2 RailwaysClearances for railways shall comply with the regulations of Transport Canada.

1.5.2.2.3 WaterwaysClearances for navigable waterways shall comply with Clause 1.9.7.1.

1.5.2.2.4 ConstructionClearances during Construction shall comply with the requirements of the agency with jurisdiction over the roadway, railway, or waterway passing through the opening.

1.6 Barriers

1.6.1 Superstructure barriersThe design of permanent barriers on structures shall comply with Section 12.

1.6.2 Roadside substructure barriersVehicular barriers or guiderails shall be provided in compliance with applicable roadside design requirements when the horizontal clearance from the roadway edge to a structure component is less than

Single user license only. S

torage, distribution or use on network prohibited.