ECE 3336 Introduction to Circuits & Electronics
Set #16Transformers
Fall 2012,TUE&TH 4:00-5:30 pmDr. Wanda Wosik
2
InductorsInductors model the interaction
between magnetic fields and voltage and current.
- Magnetic flux in webers [Wb]
3
Mutual Inductance We model this effect with what we
call “mutual inductance”, and we call it M [H]
We also rename L [H], as the “self inductance”
Magnetomotive force
vp(t)
vs(t)
vp(t)
vs(t)
v(t)=N•d/dt
turns
Voltage induced in the secondary coil in response to current changes in the primary coil.
Current direction = polarity important
http://www.allaboutcircuits.com/vol_2/chpt_9/7.html
4
The Dot ConventionPhases of the voltages in the primary and secondary windings are
identified by dots.
180° phase shift between instantaneous voltages
The same phase is obtained for both instantaneous voltages v1(t) and v2(t)
If i1 and i2 are both defined as entering (or leaving) the dotted terminal, then
n2 / n1 = -i1 / i2 = N; Otherwise,
n2 / n1 = i1 / i2 = N.
The same flux
time domain
5
From Time Domain to Phasor Domain
Hambley
The same flux
time domain
Voltage and current ratios
phasor domain
6
Power in Ideal Transformers
Note that if the voltage increases going from one side of a transformer to the other, the current decreases by the same factor.
There is no power gain. The factor is the ratio of the number of turns. We named this as the turns ratio, N.
We can tap the secondary voltage at two (or more) points
Center-tapped transformer
240 V
120V line
120V line
7
Figure 7.31, 7.32
Center-tapped transformer
Power transformers can be huge
http://www.allaboutcircuits.com/vol_2/chpt_9/7.html
Other configurations of transformers
Examples of transformers
or small
8
Impedance Reflection with Transformers
Transformers can be used to match loads (impedances). Note that
If we divide the first equation by the second, we get
9
Impedance Reflection with Transformers
Transformers can be used to match loads (impedances).
This means that if we look at the apparent impedance seen at the primary side of a transformer (Z’) we will see the impedance at the secondary side divided by the turns ratio squared.
This can be very useful. It is often referred to as the reflected impedance.
10
The maximum power transfer in AC circuits
Figure 7.35
Maximum power transfer to Rload (in DC) occurs when Rload=Rsource.
In AC circuits we will need very similar impedance matching with the source: Zs=Rs+jXs
1) The real power absorbed by Rload
Where:
2) Now, from the complex power
We calculate the real power (again)
ZL=ZS*
RL=RS and
XL=-XS
Maximum power transfer if:
When will PLMAX?
0PL=PLMAX
11
Impedance transformation improves
power delivery - example
http://www.allaboutcircuits.com/vol_2/chpt_9/7.html
The heaters (62.5Ω and 15.625Ω) of 1,000W power rating operate in two circuits a) and b).
If we use the heater a) with 125 V source the power will decrease P=250 W i.e. [(125V/62.5Ω)x125V] because I=2A
Now if we use a step-up (N=2) transformer: the current delivered to Rload is again I=4A and the power is restored to P=1,000 W
a)
b)
12
What happens with power? How to play it loud?
Maximum power would be delivered to the load of 500 Ω. But we have 8Ω.
AC Thevenin circuit
We want to supply power from a high impedance (V high I low) amplifier to a low impedance (low V high I) speaker.
A transformer will give impedance transformation ratio 500:8 so that the delivered power will reach its maximum
http://www.allaboutcircuits.com/vol_2/chpt_9/7.html
13
Figure 7.37a, b
Electric power transmission
Figure 7.37a, b, Rizzoni
(a) direct power transmission is affected by the line resistance
What will be =?We will use impedance transformation for
Reflected load here M=1/N(b) power transmission with transformers
14Figure 7.37c, d
Electric power transmission - reduction of Rline by 1/N2
Figure 7.37c, d
(c) equivalent circuit seen by generator
(d) equivalent circuit seen by load
15
Figure 7.40, 7.41
Balanced three-phase Power (AC circuit)
Figure 7.41 Rizzoni
neutral
Phase voltages
Line voltagesab, bc, ca
Positive, or abc, sequence for balanced three-phase voltages (“-” acb)
All line voltages
Wye-wye (Y-Y) connection
16
Figure 7.42
Balanced three-phase AC circuit (redrawn)
Figure 7.42
Three circuits are in parallel.
Constant! power
Can be eliminated
Advantage of the 3 phase also in less wiring (3)Compared to single phase (6 wires).
17
Figure 7.43
Delta-connected generators
Rizzoni, Figure 7.43
Currents drawn by wye-and by delta connected loads For both currents to be the same we have to have
y
Delta draws 3 times more current than a wye load does.
V=0 I=0
Loads can be also in a delta connection
Line (-to-line) voltage
18
Figure 7.50
Line voltage convention for residential circuits
red
black
white (earth ground)
This is the voltage (rms) between the hot wires
A 3-wire AC system supplied by the power company
Higher line loss will be from the 120V source. To reduce power loss (I2R) thick wires are used.
83.3A
41.7.A
Rs=0.02Ω
Power loss=69.4 W
Power loss=34.7 W
19
Figure 7.52
A typical residential wiring arrangement
Figure 7.52
•Limit power dissipation by appropriate connections fro various loads.
•Avoid heat generation (safety aspects)
20
Figure 7.58
Structure of an AC power distribution network (just for your curiosity)
Figure 7.58
Step-up transformer
That reduces power losses in transmission lines
Substations
Your house is carefully wired!