1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 a control...

3
MCAD-PLV-E5H-IP54 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D E F G H J K L M B C D E F G H J K L M A CRITICAL CHARACTERISTICS KEY CHARATERISTICS INSPECTION MUST COMPLY TO ROHS DIRECTIVE 2011/65/EU 600.0 23.62 [ ] 400.0 15.75 [ ] 100.0 3.94 [ ] 2001.0 78.78 [ ] 2156.0 84.88 [ ] 686.8 27.04 [ ] 769.8 30.31 [ ] 852.8 33.58 [ ] 935.8 36.84 [ ] 1018.8 40.11 [ ] 1101.8 43.38 [ ] 74.5 2.93 [ ] 674.0 26.54 [ ] 304.1 11.97 [ ] 384.7 15.14 [ ] 1024.0 40.32 [ ] 1328.2 52.29 [ ] 261.0 10.28 [ ] 414.8 16.33 [ ] 160.0 6.30 [ ] 185.0 7.28 [ ] 1991.9 78.42 [ ] 2026.9 79.80 [ ] 273.0 10.75 [ ] 315.0 12.40 [ ] 357.0 14.06 [ ] 596.5 23.48 [ ] 858.5 33.80 [ ] 216.0 8.50 [ ] 241.0 9.49 [ ] 286.0 11.26 [ ] 311.0 12.24 [ ] 356.0 14.02 [ ] 381.0 15.00 [ ] 568.8 22.39 [ ] 613.2 24.14 [ ] 821.5 32.34 [ ] 856.5 33.72 [ ] 911.5 35.89 [ ] 946.5 37.26 [ ] 12X 11.0 0.43 [ ] 1 OF 3 132R0264 CONFIDENTIAL: PROPERTY OF DANFOSS A/S NORDBORG, DENMARK. NOT TO BE HANDED OVER TO BE COPIED OR BE USED BY A THIRD PARTY. TWO OR THREE DIMENSIONAL REPRODUCTION OF CONTENTS TO BE AUTHORIZED BY DANFOSS A/S. SHEET MODEL 132R0264 REV DRAWING NUMBER JAN-25-19 Lauri CHECKED MAY-29-19 SABARISH DESIGNED CHANGED NOT VALID WITHOUT FROZEN DATE IN ID STAMP DESCRIPTION FINISH A1 0.150 INTERPRET DIM. & TOL. PER ASME Y14.5M-1994 ALL DIMENSIONS ARE IN MILLIMETERS TOLERANCES UNLESS OTHERWISE SPECIFIED .X # 1.0 .XX # 0.50 a # 1.0 MATERIAL SIZE SCALE THIRD ANGLE PROJECTION 002 NOTE: 1.BACK CHANNEL COOLING: BOTTOM IN TOP OUT 2.CABLE FEED: BOTTOM ENTRY & BOTTOM OUT 3.PLINTH HEIGHT CAN BE OF100,200, & 400mm HEIGHT. GROUND TERMINAL DC - TERMINAL MOTOR TERMINAL MAINS TERMINAL REFER NOTE 3 CONTROL COMPARTMENT DOOR IS NOT SHOWN IN THE DRAWING FOR SHOWING INTERNAL COMPONENTS IN CONTROL COMPARTMENT ONLY CONTROL COMPARTMENT UNIT IS SHOWN FOR BETTER CLARITY CONTROL COMPARTMENT TERMINAL -CIRCUITBREAKER

Upload: others

Post on 19-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A CONTROL …files.danfoss.com/download/Drives/MCAD-PLV-E5H-IP54... · 2019-07-04 · 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8

MCAD-PLV-E5H-IP54

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A

B

C

D

E

F

G

H

J

K

L

M

B

C

D

E

F

G

H

J

K

L

M

A

CRITICAL CHARACTERISTICSKEY CHARATERISTICSINSPECTIONMUST COMPLY TO ROHS DIRECTIVE 2011/65/EU

600.023.62[ ]400.015.75[ ]

100.03.94[ ]

2001.078.78[ ]2156.0

84.88[ ]

686.827.04[ ]

769.830.31[ ]

852.833.58[ ]

935.836.84[ ]

1018.840.11[ ]

1101.843.38[ ]

74.52.93[ ] 674.0

26.54[ ]

304.111.97[ ]

384.715.14[ ]

1024.040.32[ ]

1328.252.29[ ]

261.010.28[ ]

414.816.33[ ]

160.06.30[ ]

185.07.28[ ]

1991.978.42[ ]

2026.979.80[ ]

273.010.75[ ]

315.012.40[ ]

357.014.06[ ]

596.523.48[ ]

858.533.80[ ]

216.08.50[ ]

241.09.49[ ]

286.011.26[ ]

311.012.24[ ]

356.014.02[ ]

381.015.00[ ]

568.822.39[ ]

613.224.14[ ]

821.532.34[ ]

856.533.72[ ]

911.535.89[ ]

946.537.26[ ]

12X 11.00.43[ ]

1 OF 3132R0264

CONFIDENTIAL: PROPERTY OF DANFOSS A/S NORDBORG, DENMARK. NOT TO BE HANDED OVER TO BE COPIED OR BE USED BY A THIRD PARTY. TWO OR THREE DIMENSIONAL REPRODUCTION OF CONTENTS TO BE AUTHORIZED BY DANFOSS A/S.

SHEETMODEL132R0264

REVDRAWING NUMBER

JAN-25-19

Lauri

CHECKED

MAY-29-19SABARISH

DESIGNED

CHANGED

NOT VALID WITHOUT FROZEN DATE IN ID STAMP

DESCRIPTION

FINISHA10.150

INTERPRET DIM. & TOL. PER ASME Y14.5M-1994ALL DIMENSIONS ARE IN MILLIMETERS

TOLERANCES UNLESS OTHERWISE SPECIFIED.X�#�1.0 .XX�#�0.50 �a��#�1.0

MATERIALSIZESCALETHIRD ANGLE PROJECTION

002

NOTE:1.BACK CHANNEL COOLING: BOTTOM IN TOP OUT2.CABLE FEED: BOTTOM ENTRY & BOTTOM OUT3.PLINTH HEIGHT CAN BE OF100,200, & 400mm HEIGHT.

GROUND TERMINAL

DC - TERMINAL

MOTOR TERMINAL

MAINS TERMINAL

REFER NOTE 3

CONTROL COMPARTMENT DOORIS NOT SHOWN IN THE DRAWINGFOR SHOWING INTERNAL COMPONENTSIN CONTROL COMPARTMENTONLY CONTROL COMPARTMENT UNITIS SHOWN FOR BETTER CLARITY

CONTROL COMPARTMENTTERMINAL

-CIRCUITBREAKER

Page 2: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A CONTROL …files.danfoss.com/download/Drives/MCAD-PLV-E5H-IP54... · 2019-07-04 · 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A

B

C

D

E

F

G

H

J

K

L

M

B

C

D

E

F

G

H

J

K

L

M

A

225.08.86[ ]

474.018.66[ ]

1093.043.03[ ]

377.014.84[ ]

30.01.18[ ]

33.01.30[ ]

55.02.17[ ]

2X 555.021.85[ ]

45.51.79[ ]

588.023.15[ ]

2 OF 3132R0264SHEETMODEL

132R0264REVDRAWING NUMBER

002

COOLING CLEARANCESEE DETAIL A

AIR OUTLETTOP

AIR OUTLET

AIR INLET

AIR INLET BOTTOM

SECTION A-A

PLACE OF CONDUITS FOR MOTOR

8X DETAIL ASCALE 1.000

Page 3: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A CONTROL …files.danfoss.com/download/Drives/MCAD-PLV-E5H-IP54... · 2019-07-04 · 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A

B

C

D

E

F

G

H

J

K

L

M

B

C

D

E

F

G

H

J

K

L

M

A

134.0�$� 134.0�$�

696.827.43[ ]

407.516.04[ ]

82.93.26[ ]

173.76.84[ ]

2014.279.30[ ]

995.439.19[ ]

3 OF 3132R0264SHEETMODEL

132R0264REVDRAWING NUMBER

002