ztf detector/filter combinations p. jelinsky 2013-02-19 1

11
ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

Upload: clara-perry

Post on 03-Jan-2016

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

1

ZTF Detector/Filter Combinations

P. Jelinsky

2013-02-19

Page 2: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

2

Optics Outline

• Look at different number of detectors– Can the sky be tiled?

• Do not consider gaps.• Do not consider mapping unto a sphere

– Can it use fixed filters efficiently– Does it have a viable stagable option?

Page 3: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

3

7 detectors• Cannot use fixed filters efficiently

(since odd number of detectors)

• Can tile the sky efficiently

• No feasible stagable options.

• Maximum off axis angle: 3.2°

No Vignetting

10%Vignetting

20%Vignetting

30%Vignetting

Tile Example

Page 4: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

4

8 detectors• Can use fixed filters efficiently

• Can tile the sky efficiently

• Has a feasible stagable option.– Start with 4 detectors along center line

• Maximum off axis angle: 3.6°

No Vignetting

10%Vignetting

20%Vignetting

30%Vignetting

Fixed Filter Layout 4 Filter Stage

Page 5: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

5

8 detectors (cont)

Tile Example Fixed Filter Tile Example(Shift 2 detectors horizontal)

(then shift 2 detectors vertical)

Page 6: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

6

9 detectors• Cannot use fixed filters efficiently

• Can tile the sky efficiently

• No feasible stagable option.

• Maximum off axis angle: 3.8°

No Vignetting

10%Vignetting

20%Vignetting

30%Vignetting

Tile Example

Page 7: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

7

10 detectors• Can use fixed filters efficiently

• Can tile the sky efficiently

• Has feasible stagable option.– 6 detectors

• Maximum off axis angle: 3.8°

No Vignetting

10%Vignetting

20%Vignetting

30%Vignetting

Fixed Filter Layout 6 Detector Stage

Page 8: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

8

10 detectors (cont)

Tile Example Filter Tile Example(Do tile pattern to left)

(then shift 1 detectors horizontal)

Page 9: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

9

12 detectors• Can use fixed filters efficiently

• Can tile the sky efficiently

• Has feasible stagable option.– 8 detectors

• Maximum off axis angle: 4.1°

No Vignetting

10%Vignetting

20%Vignetting

30%Vignetting

Fixed Filter Layout 8 Detector Stage

Page 10: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

10

12 detectors (cont)

Tile Example Filter Tile Example(Shift 2 detectors horizontal)

(then shift 3 detectors vertical)

Page 11: ZTF Detector/Filter Combinations P. Jelinsky 2013-02-19 1

11

Conclusion

• 12 detector option is the most flexible– Can come on line early with 8 detectors (if needed)– Can use fixed filters (if acceptable)– Can tile the sky efficiently

• The major issue is cost