zoning hvac 13a cnst 305 environmental systems 1 dr. berryman 13equipment selection; variable air...
TRANSCRIPT
![Page 1: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/1.jpg)
Zoning
HVAC 13a
CNST 305 Environmental Systems 1Dr. Berryman
13 Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam
Piping
Chapter 3 and 7 (Toa)
14 HVAC System Design; Entering Web Bulb; Coil Lines; Zoning; Duct; Variable Air
Volume, Constant Air, Registers
Chapter 6 (Toa)
![Page 2: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/2.jpg)
Air Volume vs Temperature Constant Volume (CV)
Variable Air Volume (VAV)
![Page 3: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/3.jpg)
VAVTerminal
![Page 4: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/4.jpg)
Zoning Components
![Page 5: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/5.jpg)
Systems for Zone Control Constant Temperature, Variable
Volume (on,off) Single Zone CV Single Zone Reheat CV CV Terminal Reheat CV Dual Duct and Multizone Multiple Zone VAV ETC.
![Page 6: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/6.jpg)
Single Zone CV
Air Control on/off
Air conditions controlled at thermostat for entire zone
![Page 7: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/7.jpg)
Single Zone CV
Chiller
Boiler
Absorber Chiller
Pumps
Water Tower
Exhaust Fan
Air Handler
Air Handler
Perimeter Heating
Diffusers
System Controls
T
![Page 8: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/8.jpg)
Single Zone CV Reheat
![Page 9: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/9.jpg)
CV Terminal Reheat
![Page 10: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/10.jpg)
CV Dual Duct
![Page 11: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/11.jpg)
CV Multizone
![Page 12: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/12.jpg)
Single Zone VAV
![Page 13: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/13.jpg)
VAV Reheat
![Page 14: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/14.jpg)
VAV ReheatRoof Top Air Conditioners w/ Boilers
T
T
T
![Page 15: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/15.jpg)
VAV w/ Reheat
![Page 16: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/16.jpg)
Multiple Zone VAV
![Page 17: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/17.jpg)
Multiple Zone VAV
Roof Top Single Packaged Unit
T
T
T
Bypass Damper
![Page 18: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/18.jpg)
Multiple Zone VAV
Water Tower
Fan Powered VAV Terminals
Diffusers
Boiler
Self-Contained Air Conditioner
T
T
T
![Page 19: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/19.jpg)
Multiple Zone VAV
System Controls
T
T
T
ChillerBoiler
Absorber Chiller Pumps
Water Tower
Exhaust Fan
Air Handlers
Diffusers
VAV Terminals
Building Management System
![Page 20: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/20.jpg)
VAV Dual Duct
![Page 21: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/21.jpg)
VAV Dual Duct
System Controls
T
T
Hot Water AH
Chill Water AH
VAV Terminals
Diffusers
Direct Fired Absorber Chiller
Building Management System
![Page 22: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/22.jpg)
VAV Multizone
![Page 23: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping](https://reader036.vdocuments.mx/reader036/viewer/2022062404/55165fe1550346c6758b5f38/html5/thumbnails/23.jpg)
Next Time
Duct Systems