Zip Heaters (Aust) Pty Ltd 67-77 Allingham St, Condell Park NSW 2200 Australia 1800 42 43 44 | zipwater.com ZIP HYDROTAP G4 THE ENVIRONMENTALLY RESPONSIBLE CHOICE World class air cooled technology The following document provides information on the various options for the provision of adequate air circulation within the cupboard space Providing correct air flow results in the following: Optimal performance Up to 53% reduction in energy consumption* Reduced wear and tear on components Reduced maintenance Extended product life Reduced running costs *energy reduction compared with previous generation of products, refer to Sustainability Brochure for further details. A I R C O O L E D W A T E R C O O L E D

Upload: others

Post on 11-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ZIP HYDROTAP G4 THE ENVIRONMENTALLY ......Zip Heaters (Aust) Pty Ltd 67-77 Allingham St, Condell Park NSW 2200 Australia 1800 42 43 44 | zipwater.com ZIP HYDROTAP G4 THE ENVIRONMENTALLY

Zip Heaters (Aust) Pty Ltd 67-77 Allingham St, Condell Park NSW 2200 Australia1800 42 43 44 | zipwater.com

ZIP HYDROTAP G4

THE ENVIRONMENTALLY RESPONSIBLE CHOICEWorld class air cooled technologyThe following document provides information on the various options for the provision of adequate air circulation within the cupboard space

Providing correct air flow results in the following:• Optimal performance• Up to 53% reduction in energy consumption* • Reduced wear and tear on components• Reduced maintenance• Extended product life• Reduced running costs*energy reduction compared with previous generation of products, refer to Sustainability Brochure for further details.

AIR

COOLE D

WATER

COOLE D

AIR

COOLE D

WATER

COOLE D

AIR

COOLE D

WATER

COOLE D

AIR

COOLE D

WATER

COOLE D

Page 2: ZIP HYDROTAP G4 THE ENVIRONMENTALLY ......Zip Heaters (Aust) Pty Ltd 67-77 Allingham St, Condell Park NSW 2200 Australia 1800 42 43 44 | zipwater.com ZIP HYDROTAP G4 THE ENVIRONMENTALLY

Cool Air IN via cabinet floor, front vent grille

Warm Air OUT via kickboard louvre

MIN.50mmAir Gap

**MIN.100mm

Min 450mm

=

=

max

43

314.00

12.00

12.00

285.00

12.

00

5

326.00

CUT OUT DETAILS

A

A - KICKBOARD CUT-OUT

1.Drill 4 pilot holes Ø12 in corners2.Finish cut-out using Jigsaw and Keyhole or Wall Board saw

B - CABINET FLOOR CUT-OUT

1.Drill two pilot holes Ø122.Finish cut-out using Jigsaw

C - CABINET FLOOR CUT-OUT

1.Drill 4 pilot holes Ø12 in corners 2.Finish cut-out using Jigsawand Keyhole or Wall Board saw

ATTENTION:Insure that: Cut outs 'A' and 'B' are on opposite side of cabinet. Cut out 'C' is straight behind'A'

60.00

BC

12.00

45.00

284

For positioning of cutout C use the template marked on the cardboard carton

RECOMMENDED INSTALLATION Proper air circulation must be provided for commercial HydroTap models that have chilled or chilled sparkling functionality. The HydroTaps unique Cross-Flow kit is supplied with the product and is designed to ensure optimum efficiency using forced air flow. If this kit cannot be fitted one of the other available options will need to be installed.

HYDROTAP G4 CROSS-FLOW

Page 3: ZIP HYDROTAP G4 THE ENVIRONMENTALLY ......Zip Heaters (Aust) Pty Ltd 67-77 Allingham St, Condell Park NSW 2200 Australia 1800 42 43 44 | zipwater.com ZIP HYDROTAP G4 THE ENVIRONMENTALLY

Typical Cut out arrangement for Chilled Sparkling models with kickboard venting via a left hand appliance duct

Typical Cut out arrangement for Boiling Chilled Sparkling models with kickboard venting via a right hand appliance duct

A

A

B

C

B

C

CHILLED SPARKLING

BOILING CHILLED SPARKLING

HYDROTAP G4 CROSS-FLOW

Page 4: ZIP HYDROTAP G4 THE ENVIRONMENTALLY ......Zip Heaters (Aust) Pty Ltd 67-77 Allingham St, Condell Park NSW 2200 Australia 1800 42 43 44 | zipwater.com ZIP HYDROTAP G4 THE ENVIRONMENTALLY

HYDROTAP G4 VENT TRAY KIT

The Vent Tray Kit should be used to provide proper air circulation when the Cross-Flow kit which is supplied with commercial HydroTap models that have chilled or chilled sparkling functionality cannot be fitted. The HydroTap will only operate at its optimum efficiency if the recommended air flow is achieved.

Installation showing the correct Air Flow using the vent tray.

INSTALLATION OPTION 1

93540 assembled vent tray kit

50mm adjustment

Alignment marks

Outlet Duct

50mm

450mm cut out

1

2

Air Inlet option

Air Inlet option

Warm air Outlet vent

Page 5: ZIP HYDROTAP G4 THE ENVIRONMENTALLY ......Zip Heaters (Aust) Pty Ltd 67-77 Allingham St, Condell Park NSW 2200 Australia 1800 42 43 44 | zipwater.com ZIP HYDROTAP G4 THE ENVIRONMENTALLY

adjustable to suit the depthof the Base unit.

430

404.9

30 36

30

465

496

46

284

56.9

440.5

TOP VIEW(FRONT COVER REMOVED FOR CLARITY)

10

484 494.5

400

FRONT VIEW 40

10

88

16.2

43.6

RHS VIEW

adjustable to suit the depthof the Base unit.

430

404.9

30 36

30

284

80.7

113 46

465

496

TOP VIEW(FRONT COVER REMOVED FOR CLARITY)

10

484 494.5

400

FRONT VIEW

40

10

88

16.2

43.6

RHS VIEW

Vent Tray Kit for BC and BCS Commercial Models, part #93540

Vent Tray Kit for C and CS Commercial Models, Part #93541

HYDROTAP G4 VENT TRAY KIT

Page 6: ZIP HYDROTAP G4 THE ENVIRONMENTALLY ......Zip Heaters (Aust) Pty Ltd 67-77 Allingham St, Condell Park NSW 2200 Australia 1800 42 43 44 | zipwater.com ZIP HYDROTAP G4 THE ENVIRONMENTALLY

Installation showing the correct Air Flow using the Dual exhaust Fan kit.

The Dual Exhaust Fan Kit should be used to provide proper air circulation when the Cross-Flow kit which is supplied with commercial HydroTap models that have chilled or chilled sparkling functionality cannot be fitted. The HydroTap will only operate at its optimum efficiency if the recommended air flow is achieved.

Zip Accessories Dual exhaust Fan kit, part #93156 Dual exhaust fan kit with digital cupboard temperature controller, part 93159* *some HydroTap models do not have the 2 pin DIN plug required to run the dual exhaust fan, in these instances you will require the digital tem-perature controller to operate the fan kit.

HYDROTAP G4 DUAL EXHAUST FAN KIT

Digital controller

230V AC to 12V DC Power supply

Fan plug

Air Inlet grill

Inlet grill cut out

Exhaust fan

228

98

Exhaust fan cut out

Typical installation for BC and BCS models

INSTALLATION OPTION 2

Warm air outlet

option 2

Warm air outlet option 1