A ZigBee-PLC Gateway
for In-Home Networks
4th European ZigBee DevCon
April 28, 2010 - Munich
Rolf KistlerDipl.-Ing.Senior Researcher - iHomeLab
-
8/13/2019 zig bee ile plc haberlemesi
2/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 2 / 21
-
8/13/2019 zig bee ile plc haberlemesi
3/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 3 / 21
Smart Energy HAN Scenario
?
Infrastructure Services
Egg
Chicken
-
8/13/2019 zig bee ile plc haberlemesi
4/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 4 / 21
ENERGY
EF F IC YI E NC
-
8/13/2019 zig bee ile plc haberlemesi
5/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 5 / 21Source: E.on UK - EDRP Report
-
8/13/2019 zig bee ile plc haberlemesi
6/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 6 / 21
1st Floor
2nd Floor
Xth Floor
Basement
Smart Energy Use Case
MeterIn-Premise
Display
Smart Energy ProfileData
How to get there?
-
8/13/2019 zig bee ile plc haberlemesi
7/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 7 / 21
Pros No wires
Easy retro-fitting
IEEE PHY/MAC
Low Cost (SoC, )
Low Power
250kBit (Brutto)
Meshing capabilities
Application profiles
Security
Alliance / Brand
ZigBee No wires
Cons Physical channel / media
ISM 2.4 GHz Band
Diagnostics
One-fits-it-all compromise Complexity Emissions
-
8/13/2019 zig bee ile plc haberlemesi
8/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 8 / 21
Physical Channel Test Setups
Tooling
Graphical network-analysis and
reporting tool (keep it simple) Ping-Client and Server
File transfer-Client and Server
Tests & Locations
LOS Tests on air field and indoors
Penetration tests in bunker
(868 MHz and 2.4 GHz)
WLAN Tests in bunker Tests in elevator hoist way
2 Smart Energy PAN at university
and business sites (7-10 nodes)
-
8/13/2019 zig bee ile plc haberlemesi
9/21
-
8/13/2019 zig bee ile plc haberlemesi
10/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 10 / 21
Pros Wires everywhere
Easy retro-fitting
Power/Communication
PLC Wires everywhere
Cons Physical channel / media
Data rate
No plug, no comm.
Standardization (Hardware / coupling)
Narrow-band, In-House, Low-power, Low-cost
-
8/13/2019 zig bee ile plc haberlemesi
11/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 11 / 21
Choosing a PLC technology
Patented PulseResonance Techn.
Demokits109.6(38.4)
WattecoWPC
digitalSTROM,patented, zero-
crossing, System
Demokits(300)0.02AizodS
ZigBee-HomePlugHomePlug A/V
Specification
13751000-3800GreenPHY
Production23032-100Maxim
PRIMEPreview?21-128ST, TIOFDM
HomePlug C&CSelling215..2470.6..7.5(150)
Yitran,Renesas
DCSK
CommentsStateConsump-tion [mW]
Data rate[kpbs]
OrganizationTechno-logy
Building automation, Smart Homes: KNX/EHS, LON, CEDED CHAIN, X10, Insteon,
-
8/13/2019 zig bee ile plc haberlemesi
12/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 12 / 21
Physical Channel Test Setups
Watteco WPC 15.4 Demo-Kits
Tooling
Graphical network-analysis tool Ping-Client and Server
Locations & Tests
Laboratory
Stability, Interference
(filtered / unfiltered)
Distance
Latency Data rate
Office / University Environment
General availability
-
8/13/2019 zig bee ile plc haberlemesi
13/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 13 / 21
Physical Channel Conclusions Communication works quite well under laboratory conditions
Most newer technologies are not yet ready for SE deployment
Yes, switched power supplies and certain devices affect thecommunication and the system is dynamic and unpredictable
Filtering helps a lot
Communication at peak times, in dirty environments and
between separated circuits are problems
-
8/13/2019 zig bee ile plc haberlemesi
14/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 14 / 21
Pros No wires Wires everywhere Easy retro-fitting Application profiles Security Alliance / Brand
Power / Communication Redundancy / Reliability
Diversity / Choice Compatibility
ZigBee PLC
Cons Physical channels / media
One-fits-it-all compromise
Complexity
Alternatives: Dedicated Cabling
-
8/13/2019 zig bee ile plc haberlemesi
15/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 15 / 21
Example Network
Internet
EVU
Appliances PLC
Battery Devices RF
Mobile Devices RF
Energy Harvesting Devices RFESP
PLC-RF Transition
HA-Devices& Routers
Redundant Connections(PLC & RF)
Local (WLAN) andInternet-Connection
RF
PLC
Home-Server
-
8/13/2019 zig bee ile plc haberlemesi
16/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 16 / 21
Design - Challenge
Seamless integration Addressing
Configuration
Network Protocol (Routing, Mesh, Redundancy, Loops) Delays, retransmissions, flow control, buffering
Packet sizes, fragmentation
Broadcasts, multicasts
Security
Network analysis
-
8/13/2019 zig bee ile plc haberlemesi
17/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 17 / 21
Design Choices Layering
IEEE802.15.4
PHY
IEEE802.15.4
MAC
NetworkLayer, NWK
Transport
Layer, APS
ZigBeeSmart Energy
RF Device
PLC PHY
MAC / DLL
Network Layer
Transport
Layer
Application
Layer
PLC Device
Bridge
0110010 0110010
IEEE802.15.4PHY
PLC PHY
Router
Gateway
RF / PLC
-
8/13/2019 zig bee ile plc haberlemesi
18/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 18 / 21
Design Proposal Layering
IEEE802.15.4
PHY
IEEE802.15.4
DLL/MAC
IPv6 / ROLL6loWPAN
Application
Support
ZigBeeSmart Energy
RF Device
PLC PHY
IEEE 802.15.4
PLC MAC
IPv6 / ROLL6loWPAN
Application
Support
ZigBee
Smart Energy
PLC Device
IEEE802.15.40110010 0110010
IEEE802.15.4PHY
PLC PHY
RF/PLC Bridge
IPv6 / 6loWPAN
Configuration App
-
8/13/2019 zig bee ile plc haberlemesi
19/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 19 / 21
1st Prototype and Next Steps
State
Point-to-Point based on IEEE802.15.4 ping packets
Bridge Hardware: TI 2430 SPI WPC 15.4
Next Steps
Generic Hardware interface to test other media IPv6 / 6LoWPAN
SEP V2.0
HAN Network
-
8/13/2019 zig bee ile plc haberlemesi
20/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 20 / 21
There is still work to do and some issues needto be solved until we get there Lets do it!
Conclusions
Reliability, low cost and ease-of-use are crucial
One of the strengths of ZigBee is the SE-Profile
PLC may solve Basement-Access-Problem
Combining ZigBee RF with PLC (or other media?) Increases accessibility and reliability
Creates new opportunities on both sides Never underestimate technical challenges resultingout of suboptimal communication media types
First tests with the proposed bridge look promising
In our view SEP V2.0 incl. IPv6 is the way to go
-
8/13/2019 zig bee ile plc haberlemesi
21/21
EuZDC - April, 28 2010 - Munich Pascal Walther, Rolf Kistler 21 / 21