  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    1/17

    Ser v i c e M a n u a lcircuit diagram

    AmplifierCA1000

    CA1200

    AP1200

    AP1500

    CAP1200

    CAP1500

    Zeck AudioService departmentTurnhallenweg 6

    D-79183 WaldkirchGermany

    Phone: +49-(0)7681-2004-18Fax: +49-(0)7681-2004-972email: [email protected]

    www: www.zeck-audio.de

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    2/17

    This manual has been provided for the use of authorized service personnel. It has beenassumed that basic service procedures inherent to the industry, and more speciafically ZeckProducts, are already known and understood by the users.

    Warning: Failure to follow appropriate service and saftey procedures whenservicing this product may result in personal injury, destruction ofexpensive components and failure of the product to perform asspecified. For these reasons, we advise all Zeck product owners thatall service required should be performed by qualifized servicepersonnel.Static dischange can destroy expensive components. Discharge anystatic electricity your body may have accumulated by groundingyourself to the ground buss in the unit.

    Important: Turn the unit OFF during disassembly and parts replacement.Recheck all work before you apply power to the unit.

    Safety related Components identified by mark "!" on the schematic diagrams and

    component in the parts list are critical to safe operation. Replace thesewarning: components with Zeck orginal parts only.

    Dieses Service-Manual ist fr den Gebrauch durch authorisiertes Service-Personal bestimmt.Es wird vorausgesetzt, da der Benutzer ber grundlegende und industriebliche Kenntnisse

    im Elektronik-Service verfgt und insbesondere mit der Technik von Zeck-Produkten vertrautist.

    Warnung: Die Nichtbeachtung von Service- und Sicherheits-Richtlinien kann beiArbeit an diesem Gert zu krperlichen Schden, Zerstrung wert-voller Bauteile und zum Ausfall des Gertes fhren. Aus diesemGrunde empfehlen wir dem Benutzer dringend, alle anfallendenService-Arbeiten ausschlielich qualifiziertem Personal zu berlassen.Eventuell vorhandene elektrostatische Aufladungen knnen wertvolleBauteile zerstren. Vor der Arbeit an dem Gert sollte der Service-Techniker sich daher durch Berhren des Schaltungs-Nullpunkts desGertes von jedweder elektrostatischer Aufladung befreien.

    Wichtig: Vor ffnung des Gertes und whrend des Auswechselns vonBauteilen mu das Gert abgeschaltet sein.

    Sicherheits- Fr die Funktion des Gertes kritische Bauteile sind durch das Symbolrelevante "!" im Schaltplan und in der Ersatzteileliste markiert. DieseBauteile Bauteile drfen nur durch original Zeck-Ersatzteile ersetzt werden.

    (c) Zeck-Service nderungen vorbehalten Nachdruck und Vervielfltigung nur mit Genehmigung von Zeck Audio

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    3/17

    CA-Serie

    CA-Serie (c) Zeck-Service nderungen vorbehalten Nachdruck und Vervielfltigung nur mit Genehmigung von Zeck Audio

    AP-SerieAP-Serie

    CAP-SerieCAP-Serie

    Die vorlieg end en Sc ha ltungs-Unte rlag en fr die End stufen de r CA-Serie knnen unte rBea c htung folge nd er Hinweise a uc h fr d ie AP- und CAP-Serie ge nutzt we rd en:

    Die AP-Serie ent sp richt we itestg ehe nd de r CA-Serie, jed oc h e ntf llt d er Dyloc -

    Prozessor sow ie d ie LED-Leistung sa nzeige . Die Trafo leistun g en und Sekund r-

    spannungen wurden fr die Modelle AP1500 und AP1800 entsprechend erhht.

    Die C AP-Serie e ntsp richt e b enfa lls we itestg ehe nd de r CA-Serie, jedo c h ent f llt d ieLED-Leistun g sa nzeig e. Die Tra fole istung en- un d Sekund rsp a nnung en wu rd en fr d ie

    Modelle CAP1500 und CAP1800 entsprechend erhht.

    AP-SerieAP-Serie

    CAP-SerieCAP-Serie

    These c irc uit d ia gram s a re origina lly intend ed for use w ith our CA series a mp lifiers.They c an a lso b e used for our AP a nd C AP series a mp lifiers, howe ver, with the

    following deviations:

    The A P series a mp lifiers a re b a sica lly strip pe d -do wn v ersions of t he C A series a mp lifiers,without the Dyloc c irc uit and without the o utp ut p ow er LED disp lay. Tra nsformer po we r

    and sec ond ary voltage s have be en raised ac c ordingly for the AP1500 and AP1800

    models.

    The C AP series a m p lifiers a re a lso ve ry close va riat ions of t he C A series, the m issing LEDdisplay be ing the mo st signific ant fea ture. Transforme r pow er and sec ond ary voltag es

    have been raised accordingly for the CAP1500 and CAP1800 models.

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    4/17

    CA-Serie

    CA-Serie (c) Zeck-Service nderungen vorbehalten Nachdruck und Vervielfltigung nur mit Genehmigung von Zeck Audio

    BF872BF870

    MPS A93MPS A92MPS A43MPS A42

    2SJ502SK13510N1610P16

    2SJ562SK17620N1620P16

    BC546BC547BC560

    Abb. 1fig. 1

    Anschlubelegungen:Pinnings:

    1. Bringen Sie das Gert nach dem Einschalten in betriebswarmen Zustand.After switching on, allow the unit to warm up to its operational temperature.

    2. Widerstnde und mA-Meter in Reihe zur Betriebsspannung schalten, laut Abb. 2Connect resistors and milliammeter in series with power supply as shown in fig. 2

    3. Trimmer R114 auf der Endstufenplatine so einstellen, da das Messgert 50mARuhestrom anzeigt.Adjust trimpot R114 on output power PCB untill milliammeter reads 50mA idle current.

    4. Sollte der Ruhestrom nicht auf 50mA einzustellen sein, liegt ein Fehler auf derEndstufenplatine und/oder der Spannungsversorgung vor.If the idle current cannot be set to 50mA, suspect output power stage and/or powersupply to be defective.

    5. Entfernen Sie die Widerstnde und das mA-Meter und stellen Sie die ursprnglicheVerkabelung wieder her.Remove milliammeter and resistors and reconnect wiring.

    Abgleich:Adjustment:

    200Ohm

    200Ohm

    +U1

    -U1

    vom Netzteil

    from power supply

    EndstufenplatineOutput power PCB

    Abb. 2fig. 2

    100mA

    2SA13022SA3281

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    5/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    6/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    7/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    8/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    9/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    10/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    11/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    12/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    13/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    14/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    15/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    16/17

  • 7/31/2019 ZECK AP1200 AP1500 CA1000 CA1200 CAP1200 CAP1500

    17/17