yury kissin [email protected] windows server 2012 hyper-v and scvmm 2012

40
Yury Kissin [email protected] WindowsServer2012Hyper-Vand SCVMM2012

Upload: stewart-bond

Post on 25-Dec-2015

226 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Yury [email protected]

Windows Server 2012 Hyper-V and SCVMM 2012

Page 2: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Agenda

What's New in Hyper-V 2012Storage ImprovementsNetworking Improvements

VM Mobility Improvements

SCVMM 2012Architecture ConceptsFabric ManagementServices and ApplicationsPrivate Cloud Management

Page 3: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Hyper-V Scale ComparisonMassive Scale in the Box

Windows Server 2008 Windows Server 2008 R2 Windows Server 2012

HW Logical Processor Support

16 LPs 64 LPs 320 LPs

Physical Memory Support 1 TB 1 TB 4 TB

Cluster Scale 16 Nodes up to 1000 VMs 16 Nodes up to 1000 VMs 64 Nodes up to 4000 VMs

Virtual Machine Processor Support

Up to 4 VPs Up to 4 VPs Up to 64 VPs

VM Memory Up to 64 GB Up to 64 GB Up to 1 TB

Live Migration Yes, one at a time Yes, one at a time Yes, with no limits. As many as hardware will allow.

Live Storage Migration No. Quick Storage Migration via SCVMM

No. Quick Storage Migration via SCVMM

Yes, with no limits. As many as hardware will allow.

Servers in a Cluster 16 16 64

VP:LP Ratio 8:1 8:1 for Server12:1 for Client (VDI)

No limits. As many as hardware will allow.

Page 4: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

What's New in Hyper-V 2012

Feature/functionality New or Updated

Storage Migration New

Storage on SMB 3.0 New

Virtual Fiber Channel New

Virtual Hard Disk Format Updated

Dynamic Memory Updated

Powershell New

Hyper-V Replica New

VM Import Updated

Live Migration Updated

Virtual Machine Snapshots Updated

Client Hyper-V New

Page 5: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Virtual Hard Disks in Hyper-V 2012

Windows Server 2012 introduces the new VHDX format for virtual hard disks, which:

Supports bigger disks – Up to 64TBProtection against data corruption during power failures by logging updates to the VHDX metadata structuresSupports better alignment when deployed to a large sector diskAllows larger block size for dynamic and differencing disks, which provides better performance – 4K cluster disks

Page 6: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Converting Disks

You can perform the following maintenance operations on virtual hard disks:

Convert the disk from fixed to dynamicConvert the disk from dynamic to fixedConvert a virtual hard disk in VHD format to VHDXConvert a virtual hard disk in VHDX format to VHD

Page 7: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Location Considerations of Virtual Hard Disks

When planning the location of virtual hard disks, ensure the following:

Virtual hard disk files are stored on a volume that is configured for redundancyVirtual hard disk files are stored on high-performance storageVirtual hard disk files configured for growth should be placed on volumes with adequate space

Page 8: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Storage on SMB 3 File Shares

Hyper-V can store the following on SMB 3 files shares:Configuration filesVurtual hard disk files (in VHD and/or VHDX format)Snapshot files

** SMB 3 is available in Windows Server 2012 only, and not in earlier Windows Server versions

Page 9: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Fibre Channel Support in Hyper-V

The Fiber Channel Adapter:

Allows a virtual machine to directly connect to a Fiber Channel SANRequires that the Hyper-V host has a Fiber Channel HBARequires that the Fiber Channel HBA driver supports virtual Fibre Channel

Page 10: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Storage Migration

Storage Migration technology enables you to move a virtual machine and its storage to another location without downtime.

During migration the virtual machine hard drive is copied from one location to anotherChanges are written to both source and destination driveYou can move virtual machine storage to same host, another host, or server message block share (SMB)Storage and virtual machine configuration can be in different locations

Page 11: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Live Storage Migration

Enables Storage Load Balancing

No downtime servicing

Leverages Hyper-V Offloaded Data Transfer (ODX)

Hyper-V

Virtual Machine

Source Device Destination Device

VHD VHD

VHD Stack

1

2

3

45

Page 12: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Demo!Managing Virtual Hard Disks

in Hyper-V

Page 13: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Hyper-V Storage No Limits & Dynamic

Windows Server 2008 Windows Server 2008 R2 Windows Server 2012

Live Storage Migration No. Quick Storage Migration via SCVMM

No. Quick Storage Migration via SCVMM

Yes, with no limits. As many as hardware will allow.

VMs on File Storage No No Yes, SMB 3.0

Guest Fiber Channel No No Yes

Virtual Disk Format VHD up to 2 TB VHD up to 2 TB VHD up to 2 TBVHDX up to 64 TB

VM Guest Clustering Yes, via iSCSI Yes, via iSCSI Yes, via iSCSI or FC

Native 4k Disk Support No No Yes

Live VHD Merge No, offline. No, offline. Yes

Live New Parent No No Yes

Secure Offloaded Data Transfer (ODX)

No No Yes

Page 14: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

What's New in Hyper-V Networking?

NIC TeamingPerformance and AccelerationSecurity

Page 15: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

NIC Teaming

We can connect up to 32 NICs in a single team. That’s a lot of bandwidth!NICs in a single team can be different models from the same manufacturer or even NICs from different manufacturersMultiple teaming modes:

Generic/Static Teaming requires the switches to be configured for the team and isn’t dynamicLACP is self-discovering and enables dynamic expansion and reduction of the NICs in the teamSwitch independent works with just a single switch – switches have no knowledge of the team.

Page 16: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Performance and Acceleration

Bandwidth Management allows you to easily reserve minimum or set maximums to provide QoS controls to manage to a service level agreementDynamic Virtual Machine Queue (VMQ) uses hardware packet filtering to deliver packet data from an external virtual machine network directly to virtual machines to reduce the overhead of copying thru the Management OSIPsec Task Offload moves this workload from the main computer's CPU to a dedicated processor on the network adapterSR-IOV is a specification that allows a PCIe device to appear to be multiple separate physical PCIe devices

Page 17: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Security

DHCP Guard is a security feature that drops DHCP server messages from unauthorized virtual machines pretending to be DHCP servers.Router Guard is a security feature that drops Router Advertisement and Redirection messages from unauthorized virtual machines pretending to be routers.

Page 18: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

What's New in VM Mobility?

NIC TeamingPerformance and AccelerationSecurityBest Practices

Page 19: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Complete mobility. Simply the best.

Live Migration with High AvailabilityLive Migrate among servers in a failover cluster

SMB Live MigrationLive Migrate VMs among servers with SMB storage

Live Storage MigrationLive Migrate VM storage from one volume to another without downtime

Share Nothing (SNO) Live MigrationLive Migrate VMs among servers with nothing, but an Ethernet connection

Page 20: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Hyper-V Replica

Disaster Recovery Scenarios: Planned, Unplanned and Test FailoverPre-configuration for IP settings for primary/remote location

Key Features:RPO/RTO in minutesSeamless integration with Hyper-V and ClusteringAutomatically handles all VM mobility scenarios (e.g. Live migration)Supports heterogonous storage between primary and recoveryIntegrates with Volume Shadow Services (VSS)

Page 21: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Hyper-V Replica

Page 22: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Hyper-V Replica

Easy to SetupVia wizardOr, via PowerShell

Works with your current hardwareAll you need is two connected servers running Windows Server 2012No Guest Dependencies

Page 23: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

SCVMM 2012

Page 24: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

SCVMM 2012

SCVMM 2012 Architecture ConceptsFabric ManagementServices and ApplicationsPrivate Cloud ManagementUser Roles and ManagementService Provisioning

Page 25: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Virtual Machine Manager Management Server

VMM ConnectorWindows PowerShell

Self Service Web Portal

Console

Management Interfaces

Operations Manager Management Group

VMM 2008 R2 - Architecture

VMware vCenter

VMware ESX Hosts and Clusters

VMM Library Server

Hyper-V Hosts and Clusters

Page 26: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Virtual Machine Manager Management Server

VMM ConnectorWindows PowerShell

Self Service Web Portal

Console

Management Interfaces (Virtualization Abstraction, Storage, Networking)

Windows Software Update

Services Server

(WSUS)

Windows Deployment

Services Server (WDS)

Operations Manager Management Group

VMware vCenter

VMM 2012- Architecture

VMware ESX Hosts and Clusters

VMM Library Server

Hyper-V Hosts and Clusters

Storage and Network management

Citrix XenServer Hosts and Clusters

Page 27: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Service Managem

ent

Service Templates

Application Deploymen

t

Custom Command Execution

Image Based

Servicing

Services

Cloud Manage

ment

Application Owner Usage

Cloud Capacity

and Capabilit

y

Delegation and Quota

CloudFabric

Hyper-V Bare Metal

Provisioning

Hyper-V, VMware, Citrix

XenServer

Network Management

Storage Management

Update Management

Dynamic Optimization

Power Management

Monitoring Integration

Fabric

Management

System Center Virtual Machine Manager 2012

Page 28: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

System Center Virtual Machine Manager 2012

Service Managem

ent

Service Templates

Application Deploymen

t

Custom Command Execution

Image Based

Servicing

Services

Cloud Manage

ment

Application Owner Usage

Cloud Capacity

and Capabilit

y

Delegation and Quota

CloudFabric

Hyper-V Bare Metal

Provisioning

Hyper-V, VMware, Citrix

XenServer

Network Management

Storage Management

Update Management

Dynamic Optimization

Power Management

Monitoring Integration

Fabric

Management

Page 29: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Fabric Management

Physical ServersManage multiple hypervisors – Hyper-V, VMware, XenServer hardware management – IPMI, DCMI, SMASH, Custom via ProviderHost provisioning – from bare metal to Hyper-V to Cluster provisioning

NetworkingDefine Logical Networks using VLANs and Subnets per datacenter locationAddress management for Static IPs, Load Balancer VIPs and MAC addressesAutomated provisioning of Load Balancers via Provider (F5 and Citrix)

StorageStorage Management using SMI-S (Netapp, HP, EMC)Discover storage arrays and poolsClassify storage based on throughput and capabilitiesDiscover or configure LUNs and assign to hosts and clustersRapid provisioning of VMs using snapshot cloning of LUNs

Page 30: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Fabric Management

Update Management of Fabric ServersUpdate operation control (on-demand scan and on-demand remediation)Updating a Hyper-V cluster is fully automated/orchestratedIntegrated with Windows Server Update Server

Dynamic Optimization (DO)Cluster level workload balancing scheme to optimize VM performanceLeverages live migration to move workloads

Power Optimization (PO)Powers down servers to optimize power utilizationLeverages live migration to pack more VMs per host

Enhanced PlacementOver 100 placement checks/validationSupport for custom placement rulesMulti-VM deployment for Services

Page 31: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

System Center Virtual Machine Manager 2012

Service Managem

ent

Service Templates

Application Deploymen

t

Custom Command Execution

Image Based

Servicing

Services

Cloud Manage

ment

Application Owner Usage

Cloud Capacity

and Capabilit

y

Delegation and Quota

CloudFabric

Hyper-V Bare Metal

Provisioning

Hyper-V, VMware, Citrix

XenServer

Network Management

Storage Management

Update Management

Dynamic Optimization

Power Management

Monitoring Integration

Fabric

Management

Page 32: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Services Management

Service TemplatesUsed to model a multi-tier applicationSource of truth for deployed service configuration

ApplicationsBuilt-in support for Web deploy, Server App-V, SQL DACCustom command execution for other application packages

Image-basedOS separated from appsComposed during deployment

ServicingChange the template and then apply that change to deployed instancesUpgrade domains ensures application availability during servicing

Page 33: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

System Center Virtual Machine Manager 2012

Service Managem

ent

Service Templates

Application Deploymen

t

Custom Command Execution

Image Based

Servicing

Services

Cloud Manage

ment

Application Owner Usage

Cloud Capacity

and Capabilit

y

Delegation and Quota

CloudFabric

Hyper-V Bare Metal

Provisioning

Hyper-V, VMware, Citrix

XenServer

Network Management

Storage Management

Update Management

Dynamic Optimization

Power Management

Monitoring Integration

Fabric

Management

Page 34: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Private Cloud Management

Private CloudAbstraction that enables opaque usage model for service and VM management

FabricCompute: Logical grouping of hosts or host clusters in host groups

Storage: Storage Classifications, Pools, Providers and Arrays

Network: Logical Networks, IP/MAC Address Pools, Load Balancers, VIP Templates

Delegation - User RoleQuota: Defines per-user limits on compute, memory, storage, number of VMs

Page 35: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Cloud Capacity

Cloud can exposeAggregate capacity of underlying resources (vCPU, Memory, Storage)Oversubscription is allowed

Dimensions of CapacityNumber of CPUsAmount of MemoryType of and amount StorageNumber of deployed VMs (VMs in Library are not counted)

Page 36: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Private Cloud Usage Scenario

Configure the fabric (servers, network, storage)

Create a cloud from the fabric

Delegate the cloud to a Self Service User

Self Service User creates VMs and Services in the cloud

Page 37: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Legal ManufacturingHR

Infrastructure

Infrastructure Service A

Production Environment

Corp Net

Resources: Network access, storage allocation & quotas, access control

Infrastructure Service B

Test/Dev Environment

Dev Net Virtual LANResources: Network access, storage allocation & quotas, access control

Shared Resource Pool of

SCVMM 2012 Logical Concept

Network Storage ComputeShared Resource Pool of

Web Front Ends (SR)

Service

Reporting Servers (SR)

Service

Web Front Ends (SR)

Service

Reporting Servers (SR)

Service

Storage ComputeNetwork

Page 38: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Session Objectives and Takeaways

New in Hyper-VStorage improvementsNetwork improvementsDR/HA improvements

SCVMM 2012Fabric ManagementService Management

Page 39: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Question?

Page 40: Yury Kissin Yury@U-BTech.com Windows Server 2012 Hyper-V and SCVMM 2012

Yury [email protected]

Thank You!