your business, your comfort · 2020-05-19 · business, your comfort air conditioners light...

60
YOUR BUSINESS, YOUR COMFORT AIR CONDITIONERS LIGHT COMMERCIAL SOLUTIONS CATALOGUE 2020-2021

Upload: others

Post on 09-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

YOURBUSINESS,YOURCOMFORT

AIR CONDITIONERSLIGHT COMMERCIAL SOLUTIONS CATALOGUE 2020-2021

Page 2: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment
Page 3: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

INDEXWELCOME TO A WORLD OF INNOVATION

OUR COMMITMENT TO THE FUTURE

INVERTER SYSTEMS

LIGHT COMMERCIAL SOLUTIONS

GP_AT SUPER DIGITAL INVERTER

GM_AT8 BIG DIGITAL INVERTER

GM_ATP(8) DIGITAL INVERTER

GM_UT 4-WAY SMART CASSETTE

RM_UT 4-WAY CASSETTE

RM_MUT COMPACT 4-WAY CASSETTE

RM_BTP STANDARD DUCT

RM_SDT SLIM DUCT

RM_DTP HIGH STATIC DUCT

RM_FT FLOOR STANDING

RM_CTP CEILING

RM_KRTP HIGH-WALL

SDI-DI TWIN

RAV-DXC STANDARD DX KIT

RBC-DXC 0-10V DX KIT

RAV-CT AIR CURTAINS

04

10

14

18

20

22

24

26

28

30

32

34

36

38

40

42

44

50

52

54

Preliminary data

Page 4: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

04

It all began in Japan in 1875. Two Japanese innovators, Hisashige Tanaka, a mechanical engineering genius, and Ichisuke Fujioka, an expert of electricity, decided to join their forces in order to create a world of progress focusing on humanity and the improvement of daily life: Toshiba.

Page 5: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

05

Today, 140 years later, all of us in Toshiba are still inspired by their example. We continue to work, research and break new ground to offer you highly evolved and up to date solutions on air conditioning and heating, always caring for the environment. We stand by our founders’ initial vision by providing a better quality of life for everyone through elegant and secure products, and advanced technological machinery.

WELCOME TO A WORLD OF INNOVATION

Our products, trusted by millions of people all over the world, are based upon the unique Japanese Research & Development. Their characteristic design makes them unique and they stand out globally, as they are known to create a beautiful interior environment, no matter how harsh the conditions outside.

We are certain that even now, that Toshiba is undoubtedly a world leader in the global air conditioning market, we remain loyal to our founders’ initial vision: to create a better quality of life for everyone, no matter what their space of living is, no matter which country they inhabit, so as to make them feel comfortable and happy in a room of ideal conditions, in short – in the perfect climate!

Page 6: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

06

For every spaceHome, store, office or hotel; each building has its own unique demands and special features. Toshiba creates a perfect environment of comfort and encourages productivity. Whatever you use your space for, Toshiba is here to help you create the best possible conditions of comfort.

For every demandAlways driven by our standards for the creation of innovative high-end technological products, we offer you reliable and secure solutions that cover every possible demand. Now your world is getting simpler, clearer, and more effective thanks to the technical building usage systems of Toshiba. Whatever your situation, our groundbreaking solutions are here for you.

Page 7: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

07

For every needIn a world of infinite choices and unmeasurable possibilities, Toshiba satisfies every need. The solutions offered for heating and air conditioning match your needs perfectly, down to the smallest detail and always with the best outcome.

INNOVATIVE SOLUTIONS FOR A CONFIDENT LIVING

Page 8: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

08

Everyday technology and innovation We stand out for the high standard Japanese technology of our products, for our unparalleled innovation and our subtle design. Our aim is to offer through our products a most safe, comfortable and productive life to our trusting clients.

We combine our spirit for innovation with our passion for a better future. Protecting the environment is our guiding commitment, since it is our common heritage throughout the planet. We cultivate close relations based upon mutual trust and respect. What drives us is our strong bonds with our clients, our business associates and communities all around the world.

Page 9: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Eurovent programme Eurovent is an independent European organization with the strictest requirements globally, which verifies that the technical features and performance of air conditioning products follow all European guidelines.

All Toshiba residential products are certified by Eurovent programme. This is a guarantee for customers and users that our products will operate in accordance with the design specifications and that their published technical characteristics, performance and Energy Ratings are true.

COMMITED TO A BETTER WORLD FOR A FACT

09

To improve its environmental responsibility, Toshiba Air Conditioning offers products that meet the following European standards:

This directive determines the requirements and performance measurements of air conditioners and heat pumps.

This directive determines the methodology for the calculation of seasonal performance for space heating and cooling of air conditioners and heat pumps, with electrical driven compressors.

This directive involves heat pumps with electrical driven compressors and determines the requirements for marking domestic hot water units.

European standards

EN 14511 EN 14825 EN 16147

The Regulation aims to progressively abolish the use of hydrocarbons in future heating and cooling systems.

517/2014 F-gas

Page 10: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

The planet is our home

It is imperative for us to play an active role in protecting our planet; it is something we defend daily. At Toshiba Air Conditioning, we believe we can make a difference. We are committed to advancing research and developing super-energy-efficient technologies. This commitment is in line with the European Union's climate and energy objectives for 2030.

Toshiba Air Conditioning also assesses the impact of its business activities, products and services on the environment and sets targets aiming to reduce environmental impact and prevent pollution.

10

27%SHARE OF

RENEWABLE ENERGY

Sour

ce: T

OSH

IBA

CORP

ORA

TIO

N E

nviro

nmen

tal R

epor

t 201

6

Concurrently Toshiba Group is also conducting group-wide environmental activities based on the recognition of the importance of maintaining and expanding environments for conserving biodiversity.

59%REDUCTION

45%REDUCTION

created at production &business sites worldwide

from 2012 to 2015

62BIOTOPES

inhabit Toshiba Group’sproduction & business

sites worldwide

100RARE SPECIES

89%REDUCTION

27%IMPROVEMENT

IN ENERGY EFFICIENCY

-40%GREENHOUSE

GAS EMISSIONS

in total volume of CO2emissions from

1990 to 2015

in total volume of wastegenerated from

2000 to 2015

in total volume ofchemical emissionsfrom 2000 to 2015

Page 11: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

11

OUR COMMITMENT TO THE FUTURE,STARTING FROM TODAY

Environmental action plan

In order to realize an ideal state of the Earth in 2050, Toshiba Group formulates Environmental Action Plan for medium-term goals and manages specific environmental activities and their targets. Under the ongoing Sixth Environmental Action Plan for the period from FY2017 to FY2020, we set goals for 15 items in two areas: or namely activities to reduce environmental impacts in the lifecycles of products and services (Business), and basic activities to support such activities (Management).

Developing Strategies in Two Areas: Business and ManagementEnvironmental Vision 2050

Helping resolve global environmental issues

Business

ManagementPromoting basic activities that support business initiatives

Creating a system that supports strict compliance and enhancing basic activities to meet public expectations

Pursuing high-efficiency manufacturing thatsimultaneously reduces environmental impacts and costs

Promoting initiatives to reduce environmental impacts in product/service lifecyclesReducing environmental impacts in manufacturing

Development of energy technologies and energy-savingproducts and services to help realize a low-carbon society

Improving environmental performance of products and services

Reduction of GHGemissions

Reduction of wasteand water received

Reduction ofchemicals discharged

Ensuring of environmental risk compliance Environmental communication Conservation of biodiversity

Further reductionof CO2 emissions

More resourcesconserved or

recycled

Reduction of specifiedchemical substances

contained in products

Page 12: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Products designed to perform, engineered to perfection

Digital DC Twin Rotary Inverter Compressor

Ensures a steady rotation speed and reduces any unwanted vibration. The results are unique:

Increased efficiency

The compressor has a particularly high efficiency

at low rotational speeds and during long-running

steady conditions.

Energy saving

Thanks to the anti-asymmetric

twin-cylinder rotation, the compressor offers great energy savings and very

powerful and reliable operation.

High reliability& low noise level

Stable performance with minimal friction loss. The ideal

solution for noise-sensitive applications. The noise of the outdoor unit during operation is almost negligible, and at the

same time it ensures double lifespan for the compressor.

12

Page 13: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

13

Environmental friendlyToshiba units perfectly keep the balance between environment safety and comfort, along with the increased energy efficiency for greater savings.

Reducing the CO2 emissionsR32 low GWP, combined with Toshiba’s units 30% reduction of refrigerant charge, allows to reduce the total equivalent CO2 by 80% of the system, in comparison with equivalent capacities of Toshiba R410A legacy units.

ONLY EXCELLENCE CAN BE NAMED TOSHIBA

Easy to install► Working pressures for R410A and R32 refrigerant are similar► R32 refrigerant can be easily charged in both liquid or gas state► Safety commissioning instructions are similar to those for R410A► R32 and R410A equipments are the same, except the refrigerant recovery pump and the reclaim cylinder► Toshiba flare joints are ISO14903 certified, in anticipation of the new IEC60335-2-40 edition 5 regulation, which will allow flare connection inside the room.

GWP (1)

ODP (2) X.XXR23(HFC) R12(CFC) R11(CFC) R22 (HCFC) R410A (HFC) R32 (HFC) CO 2

1.0 X.XX 0.05 0 X.XX

14.800 10.900

1987 - The Montreal Protocol

4.750 1.810 2.090

Around1/3

1

675

1997 - The Kyoto Protocol

LIFE-CYCLE CLIMATE PERFORMANCE

R410A

R32SUZUMI+ R32Vs SUZUMI+ R410A

100%(0.81kg)

2088 1670

675344

(0.51kg)

63%x = -80%

GWP Unit refrigerant charge (% / kg)

CO2 equivalent (kg) GWP x Refrigerant charge

(1) Global Warming Potential(2) Ozon Depletion Potential

Page 14: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

14

High performance and minimised consumptionThe Toshiba Digital and Super Digital Inverter systems are powerful and extremely efficient. They provide air conditioning with great energy savings.The Super Digital Inverter provides the best performance in the industry on part load conditions, both in cooling and heating mode. In most applications, these systems can reduce the Seasonal Energy Consumption.The variable capacity management of the compressor allows the Digital and Super Digital Inverter to maintain the control of the room temperature and to ensure minimum energy wastage.

Unparalleled flexibilityFor the professionals seeking high perfor-mance, compact units and optimum comfort, Toshiba has the ideal product.Toshiba never ceases improving the inverter control system: the vector control for its DC hybrid inverter enhances system efficiency and reduces noise levels. High-tech elements include improved coils, high precision components and higher refrigerant compression, thanks to rede-signed compression channels.Super Digital and Digital Inverter systems are able to satisfy applications that require cooling up to +52°C (+46°C for DI) and heating down to -27°C (-20°C for DI).DC twin-rotary compressor delivers stable perfor-mance with extremely low rotor friction, making it ideal for noise-sensitive applications, as well as for efficient operations in partial load conditions.

Inverter becomes DigitalThe Digital Inverter control module technology ensures optimised reproduction of the sine wave supply at the desired frequency, in order to reduce inefficient harmonics that inverters normally emit.With this innovative control method, the Toshiba Digital Inverter brings state-of-the-art inverter technology to the commercial sector, offering great advantages in terms of capacity, energy savings and optimised comfort.

Page 15: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

15

Maximum efficiencyVery efficient energy consumption, keeps down operating costs: SEER of 9,40 and SCOP of 5,51 achieved by Toshiba’s unrivalled Super Digital Inverter technologies and newly developed components.

Piping flexibilitySuper Digital Inverter, leader in the industry, efficiently supports the height differences, of up to 30 meters, on a single system. Enough height to cover an 8-storey building! Consequently, the outdoor unit can be installed out of sight, increasing installation flexibility (only 4 & 5HP).

DC Twin rotary compressor and vector-controlled InverterThe advantages of inverter technology are further optimised when combined with Toshiba twin-rotary compressors, giving exceptional speed control in the capacity range from 20 to 100% capacity: a unique Toshiba benefit!

Operating temperature rangeHeater operation starts from an outdoor temperature of -27°C, creating a comfortable space even during cold winters, while cooling operation is possible up to 52°C outdoor temperature. This enables wider applications and use of the system in colder regions.

RAV Super Digital InverterToshiba Super Digital Inverter series perfectly combine economy and ecology in a compact body. They feature state-of-the-art technology, flexible control, and easy installation, for great comfort and convenience to any business environment. SDI outdoor units are compatible with a complete range of indoor units: Cassette, Ducted, Ceiling and High-Wall units.

INVERTER SYSTEMS

8F7F6F5F4F3F2F1F

Sing

le s

yste

m Height

between

indoor units

30m

cooling mode

Temperatureoperating

range

heating mode

Page 16: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

16

RAV Digital InverterToshiba continues to improve its range of split systems dedicated to commercial applications. Digital Inverter (DI) has been totally redesigned, becoming more compact and more effective. The performance of these systems provide significant energy savings for a rapid return on investment. Comfort, ease of installation and simplicity are the strengths of Toshiba systems.

Small and light chassisLess than 900mm up to 5HP, the Digital Inverter is extremely compact and can be installed in very small spaces. In addition, chassis under 5HP are less than 70kg.

Wide capacity range▪ 9 sizes from 1HP to 10HP with 1Ph or 3Ph electrical ▪ Connection to cover every type of projects, from the 15m² room to the 200m² shop, in new construction and refurbishment as well

Smart InverterHybrid inverter control combines two intelligent control mechanisms to reach the set point temperature as quickly as possible with maximum efficiency:▪ Τhe PAM mode, quickly achieves high capacity and desired comfort.▪ Τhe PWM mode minimizes power input to maximize efficiency.

The result: high efficiency level.

550mm

890mm

1HP to 3HP 4HP & 5HP

1HP 1.5HP 2HP 3HP 4HP 5HP 6HP 8HP 10HP

1Ph

3Ph

✔ ✔ ✔

Operating temperature rangeOperation is possible starting from an outdoor temperature of -15°C (-27°C for Big DI), while cooling operation is possible at -15°C and up to 46°C (52°C for Big DI) outdoor temperature. This enables wider applications and use of the system everywhere.

Temperatureoperationrange (in °C)

cooling mode

heating mode

Page 17: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

17

INVERTER SYSTEMS

Page 18: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

18

Professional solutionsfor professional needsToshiba Digital and Super Digital Inverter systems are extremely compact units with exceptional operating savings. State-of-the-art technologies, flexible controls and improved installation go along with comfort and convenience, for all kind of business installations.

Ceiling, cassette, ducted, suspended and high-wall: a complete range of indoor units ready to suit all commercial applications. All Toshiba systems, expanded with maximum cooling capacities of up to 27kW, benefit additional commercial applications with larger volumes.

Page 19: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

LIGHT COMMERCIAL SOLUTIONS

Page 20: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

5,51

SCOP MAX

The Toshiba Super Digital Inverter series is leading energy efficiency, operating range and piping length, offering the best solution for the majority of commercial projects and large residential applications.

Power consumption analysis embedded when SDI series is combined with theRBC-AMS55E-ES/-EN.

TOP CLASS EFFICIENCY► High efficiency SCOP of up to 5,51, thanks to Toshiba inverter technology

WIDE ADAPTABILITY► Operating temperature limits from -27°C (Heating) to +52°C (Cooling) allow the system to operate across a wide temperature range► Quiet operation

FLEXIBLE► Can be utilised for single, twin or triple indoor applications

EASY MAINTENANCE► Removable corner panels for easy access► Self-diagnosis function

5kW-14kW

CAPACITY

-27°C/+52°C

OPERATION

POWER CONSUMPTION(WEEK)

20

Page 21: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Physical data outdoor - Single phase

Air Flow

Sound pressure level

Sound power level

Operating range

Sound pressure level

Sound power level

Operating range

Dimensions (HxWxD)

Weight

Compressor type

Flare connections

Gas

Liquid

Minimum pipe length

Maximum pipe length

Maximum height difference

Chargeless pipe length

Refrigerant

Power supply

C = cooling mode H = heating mode

m3/h - l/s

dB(A)

dB(A)

°C

dB(A)

dB(A)

°C

mm

kg

in

in

m

m

m

m

Type/kg

V-ph-Hz

C

C

C

H

H

H

Outdoor unitRAV-GP561ATP-E

2 HP

2.250-625

46

63

-15 / 52

48

65

-27 / 15

630x799x299

45

DC Twin Rotary

1/2

1/4

3

50

30

20

R32 / 1,35

220/240-1-50

RAV-GP801AT-E3 HP

3.180-883

46

63

-15 / 52

48

65

-27 / 15

1.050x1.010x370

74

DC Twin Rotary

5/8

3/8

3

50

30

30

R32 / 1,9

220/240-1-50

RAV-GP1101AT-E4 HP

6.960-1.933

49

66

-15 / 52

50

67

-27 / 15

1.550x1.010x370

104

DC Twin Rotary

5/8

3/8

3

75

30

30

R32 / 3,1

220/240-1-50

RAV-GP1401AT-E5 HP

6.960-1.933

50

67

-15 / 52

51

68

-27 / 15

1.550x1.010x370

104

DC Twin Rotary

5/8

3/8

3

75

30

30

R32 / 3,1

220/240-1-50

Physical data outdoor - Three phase

Outdoor unit

Air Flow

Sound pressure level

Sound power level

Operating range

Sound pressure level

Sound power level

Operating range

Dimensions (HxWxD)

Weight

Compressor type

Flare connections

Gas

Liquid

Minimum pipe length

Maximum pipe length

Maximum height difference

Chargeless pipe length

Power supply

C = cooling mode H = heating mode

m3/h - l/s

dB(A)

dB(A)

°C

dB(A)

dB(A)

°C

mm

kg

in

in

m

m

m

m

V-ph-Hz

C

C

C

H

H

H

RAV-GP1101AT8-E4 HP

6.060 - 1.683

49

66

-15 / 46

50

67

-20 / 15

1340x900x320

95

DC Twin Rotary

5/8

3/8

3

75

30

30

380/415-3N-50

RAV-GP1401AT8-E5 HP

6.180 - 1.717

51

68

-15 / 46

52

69

-20 / 15

1340x900x320

95

DC Twin Rotary

5/8

3/8

3

75

30

30

380/415-3N-50

RAV-GP1601AT8-E6 HP

6.180 - 1.717

51

68

-15 / 46

53

70

-20 / 15

1340x900x320

95

DC Twin Rotary

5/8

3/8

3

75

30

30

380/415-3N-50

21

GP_AT SUPER DIGITAL INVERTER

Page 22: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

3,51

SCOP MAX

Big DI has been designed to provide a high capacity output from a very small foot print.

The installation can reach up to 60m total piping length and 30m in elevation without additional safety measures.

HIGH EFFICIENCY & ENERGY SAVINGS► Best EER and COP in its class incorporating Toshiba’s exclusive Inverter twin-rotary compressor made in Japan► Compliant with ERP directive lot 21► Top class part load efficiency

WIDE ADAPTABILITY► Allows connection of four indoor units (same type and capacity) to one outdoor unit► Compatible with a wide choice of indoor units: 4-way cassette, 4-way compact cassette, slim duct, standard duct, high-wall and ceiling

SAFETY & RELIABILITY► Built-in leak detection system► Compliant with the child finger entrapment regulation

19kW-27kW

CAPACITY

-27°C/+46°C

OPERATION

22

Page 23: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Physical data outdoor - Three phase

Outdoor unit

C = cooling mode H = heating mode

m3/h - l/s

dB(A)

dB(A)

°C

dB(A)

dB(A)

°C

mm

kg

in

in

m

m

m

m

V-ph-Hz

C

C

C

H

H

H

RAV-GM2241AT8-E8 HP

9.150 - 2.541

58

76

-15 / 46

60

76

-27 / 15

1.550x1.010x370

142

DC Twin Rotary

1 1/8

1/2

5

60

30

30

380/415-3N-50

RAV-GM2801AT8-E10 HP

10.890 - 3.025

61

78

-15 / 46

63

80

-27 / 15

1.550x1.010x370

142

DC Twin Rotary

1 1/8

1/2

5

60

30

30

380/415-3N-50

Air Flow

Sound pressure level

Sound power level

Operating range

Sound pressure level

Sound power level

Operating range

Dimensions (HxWxD)

Weight

Compressor type

Flare connections

Gas

Liquid

Minimum pipe length

Maximum pipe length

Maximum height difference

Chargeless pipe length

Power supply

23

GM_AT8 BIG DIGITAL INVERTER

Page 24: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

4,51

SCOP MAX

Toshiba Digital Inverter brings state-of-the-art inverter technology to the commercial sector, offering considerable advantages in terms of capacity, energy savings, optimised control, lower refrigerant charge. In addition, it has the smallest physical dimensions and lightest range of outdoor units in the industry.

Toshiba state-of-the-art compressor features a powerful magnetic rotor with great surface area to increase efficiency and reduce the operation noise.

☻Efficiency☻Reliability☻100% Toshiba

LIGHT & COMPACT► Up to 14kW in only 890mm height and 69kg

WIDE ADAPTABILITY► Compatible with a wide choice of indoor units: 4 way cassette, 4-way compact cassette, slim duct, standard duct, high wall and ceiling► Night operation mode to minimize the outdoor unit sound as low as 33dB(A)

EFFICIENCY & ENERGY SAVINGS► The Vector Intelligent Drive Unit (IPDU) technology ensures power limitation by 1% step between 50% and 100% load for optimal capacity control

EASY MAINTENANCE► Removable corner panels for easy access► Auto diagnostic function

2kW-16kW

CAPACITY

-15°C/+46°C

OPERATION

24

Page 25: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Physical data outdoor - Single phase

Physical data outdoor - Three phase

m3/h - l/s

dB(A)

dB(A)

°C

dB(A)

dB(A)

°C

mm

kg

in

in

m

m

m

m

V-ph-Hz

C

C

C

H

H

H

Outdoor unitRAV-GM301ATP-E

1 HP

1.800 - 500

46

61

-15 / 46

47

62

-15 / 15

550x780x290

33

DC Rotary

3/8

1/4

2

20

10

15

220/240-1-50,

220-1-60

RAV-GM401ATP-E1.5 HP

2.200 - 611

49

64

-15 / 46

50

65

-15 / 15

550x780x290

39

DC Twin Rotary

1/2

1/4

2

20

10

15

220/240-1-50,

220-1-60

RAV-GM561ATP-E2 HP

2.400 - 667

46

63

-15 / 46

48

65

-15 / 15

550x780x290

40

DC Twin Rotary

1/2

1/4

5

30

30

20

220/240-1-50

220-1-60

RAV-GM801ATP-E3 HP

2.700 - 750

48

65

-15 / 46

52

69

-15 / 15

550x780x290

44

DC Twin Rotary

5/8

3/8

5

30

30

20

220/240-1-50

220-1-60a

RAV-GM901ATP-E3.5 HP

2.900 - 806

51

68

-15 / 46

55

72

-15 / 15

630x800x300

47

DC Twin Rotary

5/8

3/8

5

50

30

30

220/240-1-50

220-1-60

RAV-GM1101ATP-E4 HP

4.080 - 1.133

54

70

-15 / 46

57

74

-15 / 15

890x900x320

68

DC Twin Rotary

5/8

3/8

5

50

30

30

220/240-1-50

220-1-60

RAV-GM1601ATP-E6 HP

6.900 - 1.917

53

70

-15 / 46

55

72

-15 / 15

1.340x900x320

95

DC Twin Rotary

5/8

3/8

5

50

30

30

220/240-1-50

220-1-60

RAV-GM1401ATP-E5 HP

4.200 - 1.167

55

70

-15 / 46

57

74

-15 / 15

890x900x320

68

DC Twin Rotary

5/8

3/8

5

50

30

30

220/240-1-50

220-1-60

Air Flow

Sound pressure level

Sound power level

Operating range

Sound pressure level

Sound power level

Operating range

Dimensions (HxWxD)

Weight

Compressor type

Flare connections

Gas

Liquid

Minimum pipe length

Maximum pipe length

Maximum height difference

Chargeless pipe length

Power supply

C = cooling modeH = heating mode

C = cooling mode H = heating mode

m3/h - l/s

dB(A)

dB(A)

°C

dB(A)

dB(A)

°C

mm

kg

in

in

m

m

m

m

V-ph-Hz

C

C

C

H

H

H

4.080 - 1.133

54

70

-15 / 46

57

74

-15 / 15

890x900x320

69

DC Twin Rotary

5/8

3/8

5

50

30

30

380/415-3-50,

380-3-60

4.200 - 1.167

55

70

-15 / 46

57

74

-15 / 15

890x900x320

69

DC Twin Rotary

5/8

3/8

5

50

30

30

380/415-3-50,

380-3-60

Air Flow

Sound pressure level

Sound power level

Operating range

Sound pressure level

Sound power level

Operating range

Dimensions (HxWxD)

Weight

Compressor type

Flare connections

Gas

Liquid

Minimum pipe length

Maximum pipe length

Maximum height difference

Chargeless pipe length

Power supply

RAV-GM1101AT8P-E4 HP

RAV-GM1401AT8P-E5 HP

6.900 - 1.917

53

70

-15 / 46

55

72

-15 / 15

1.340x900x320

94

DC Twin Rotary

5/8

3/8

5

50

30

30

380/415-3-50,

380-3-60

RAV-GM1601AT8P-E6 HPOutdoor unit

25

GM_ATP(8) DIGITAL INVERTER

Page 26: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

5,51

SCOP MAX

Dedicated for commercial application, the Toshiba smart cassette is the perfect mix between comfort, elegance and efficiency.

Louver position automatically adjusts to prevent cold draught being felt by users.

EFFICIENCY► Top class SEER and SCOP, thanks to long slit heat exchanger with magic coil treatment, high efficiency fan motor and large opening air conditioning ventilation► Energy saving with the occupancy sensor which will automatically switch off the unit if nobody is in the room

COMFORT► Unique flap design for optimal air distribution► Individual setting of louver position: 3 different swing modes: standard, diagonally, opposite or turn around► 5 fan steps to precisely control the air flow

DESIGN► Simple & elegant design fits various rooms

5kW-14kW

CAPACITY

-27°C/+52°C

OPERATION

26

Page 27: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Performance data with Super Digital Inverter

C = cooling mode H = heating mode

Physical data indoor

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Cassette)

RAV-GP561ATP-ERAV-GM561UT-E

5,0

1,2-5,6

0,19-1,20-2,03

4,17

8,07

A++

217

5,6

0,9-7,4

0,16-1,29-2,76

4,34

5,01

A++

1.061

RAV-GP801AT-ERAV-GM801UT-E

7,1

1,9 - 8,0

0,26-1,37-2,94

5,18

9,40

A+++

264

8,0

1,3 - 11,3

0,20-1,45-3,15

5,52

5,51

A+++

1.294

RAV-GP1101AT-ERAV-GM1101UT-E

10,0

3,1 - 12,0

0,56-1,90-2,80

5,26

8,80

A+++

398

11,2

2,6 - 13,0

0,41-2,18-2,98

5,14

5,00

A++

2.573

RAV-GP1401AT-ERAV-GM1401UT-E

12,5

3,1 - 14,0

0,56-2,91-3,40

4,30

8,30

TBD

903

14,0

2,6 - 16,5

0,41-3,04-4,18

4,61

4,97

TBD

2.702

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

m3/h - l/s

dB(A)

dB(A)

mm

kg

mm

kg

Indoor unit RAV-GM561UT-E

1.050/750 - 291/208

32-29-26

48-45-43

256×840×840

20

30×950×950

5

RAV-GM801UT-E

1.920/810 - 533/225

42-35-27

56-49-43

319×840×840

25

30×950×950

5

RAV-GM1101UT-E

2.250/1050 - 625/291

48-40-31

61-54-46

319×840×840

25

30×950×950

5

RAV-GM1401UT-E

2.250/1170 - 625/325

48-41-33

61-55-48

319×840×840

25

30×950×950

5

Air Flow (H/L)

Sound pressure level (H-M-L)

Sound power level (H-M-L)

Dimensions (HxWxD)

Weight

Panel dimensions (HxWxD)

Panel weight

C = cooling mode H = heating mode

27

GM_UT 4-WAY SMART CASSETTE

Page 28: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

5,22

SCOP MAX

4-way cassette is designed to provide uniform air distribution and total comfort. It is the ideal solution for small commercial application.

Optimal air diffusion up to 4,6m ceiling height!

COMFORT► Two louvers shape option: straight flow louver and wide flow louver; optimum air distribution► Individual setting of louver position: 3 different swing mode: standard, diagonally, opposite, turn around► Wide air flow in all directions

RELIABILITY► Self-cleaning function and Ag-ion tip for anti-mould in drain cap► Built-in high-lift drain pump

EASY INSTALLATION► Compact chassis with only 256mm height (sizes 5 and 8)► Light-weight unit, for easy and quick installation

5kW-16kW

CAPACITY

-27°C/+52°C

OPERATION

4,6 m

Max height

28

Page 29: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

29

RM_UT 4-WAY CASSETTE

Performance data with Super Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Cassette)

RAV-GP561ATP-ERAV-RM561UTP-E

5,0

1,2-5,6

0,19 -1,22 -1,97

4,10

7,61

A++

230

5,6

0,9-8,1

0,16 -1,30 - 2,76

4,31

4,96

A++

1.071

RAV-GP801AT-ERAV-RM801UTP-E

7,1

1,9 - 8,0

0,26 - 1,58 - 3,15

4,49

8,80

A+++

282

8,0

1,3 - 11,3

0,20 - 1,77 - 3,47

4,52

5,22

A+++

1.367

RAV-GP1101AT-ERAV-RM1101UTP-E

10,0

3,1 - 12,0

0,53 - 2,13 - 3,05

4,69

8,65

A+++

405

11,2

2,6 - 13,0

0,40 - 2,34- 3,08

4,79

4,73

A++

2.719

RAV-GP1401AT-ERAV-RM1401UTP-E

12,5

3,1 - 14,0

0,53 - 3,16 - 3,55

3,96

8,15

TBD

920

14,0

2,6 - 16,5

0,40 - 3,21 - 4,38

4,36

4,72

TBD

2.844

RAV-GP1101AT8-ERAV-RM1101UTP-E

10,0

2,6 - 12,0

0,66 -2,32- 3,60

4,31

7,1

A++

492

11,2

2,4 - 15,6

0,53 -2,41 - 4,30

4,65

4,36

A+

3.047

RAV-GP1401AT8-ERAV-RM1401UTP-E

12,5

2,6 - 14,0

0,66 - 3,42 - 4,40

3,65

7,01

TBD

1.069

14,0

2,4 - 18,0

0,53 -3,41 - 5,50

4,11

4,36

TBD

3.049

RAV-GP1601AT8-ERAV-RM1601UTP-E

14,0

2,6 - 16,0

0,66 - 4,34 - 5,70

3,23

6,72

TBD

1.249

16,0

2,4 - 19,0

0,53 -4,28 - 6,51

3,74

4,36

TBD

3.049

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Performance data with Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (4-way Cassette)

RAV-GM561ATP-ERAV-RM561UTP-E

5

1,5 - 5,6

0,26 -1,56 - 1,86

3,21

6,34

A++

276

5,3

1,5 - 6,3

0,26 -1,36 - 2,08

3,90

4,60

A++

852

RAV-GM801ATP-ERAV-RM801UTP-E

6,7

1,5 - 8,0

0,26 - 2,22 - 2,60

3,02

5,81

A+

403

7,7

1,5 - 9,0

0,26 -2,13- 3,03

3,62

4,42

A+

1.615

RAV-GM901ATP-ERAV-RM901UTP-E

8,0

1,9 - 8,8

2,42

3,30

7,00

A++

389

9,0

1,6 - 9,9

2,65

3,72

4,60

A++

1.917

RAV-GM1101ATP-ERAV-RM1101UTP-E

9,5

3,0 - 11,2

0,60 - 2,87- 4,10

3,31

6,15

A++

540

11,2

3,0 - 13,0

0,60 -2,93 - 4,30

3,82

4,28

A+

2.615

RAV-GM1101AT8P-ERAV-RM1101UTP-E

9,5

3,0 - 11,2

0,60 - 2,87 - 4,10

3,31

6,15

A++

540

11,2

3,0 - 13,0

0,60 -2,93 - 4,30

3,82

4,28

A+

2.615

RAV-GM1401ATP-ERAV-RM1401UTP-E

12

3,0 - 13,2

0,60 -4,29 - 4,71

2,8

5,71

A+

736

13,0

3,0 - 16,0

0,60 - 3,46 - 4,50

3,76

4,29

A+

2.611

RAV-GM1401AT8P-ERAV-RM1401UTP-E

12

3,0 - 13,2

0,60 -4,29 - 4,71

2,8

5,71

A+

736

13,0

3,0 - 16,0

0,60 - 3,46 - 4,50

3,76

4,29

A+

2.611

RAV-GM1601ATP-ERAV-RM1601UTP-E

14,0

3,0 - 16,0

4,49

3,12

6,3

TBD

1.033

16,0

3,0 - 18,0

4,43

3,61

4,35

TBD

2.575

RAV-GM1601AT8P-ERAV-RM1601UTP-E

14,0

3,0 - 16,0

4,49

3,12

6,3

TBD

1.033

16,0

3,0 - 18,0

4,43

3,61

4,35

TBD

2.575

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Physical data indoor

m3/h - l/s

dB(A)

dB(A)

mm

kg

mm

kg

Indoor unit RAV-RM561UTP-E

1.050/780 - 291/217

32-29-28

47-44-43

256×840×840

20

30×950×950

4,2

RAV-RM801UTP-E

1.230/810 - 341/225

35-31-28

50-46-43

256×840×840

20

30×950×950

4,2

RAV-RM1101UTP-E

2.010/1170 - 558/325

43-38-33

58-53-48

319×840×840

24

30×950×950

4,2

RAV-GM901UTP-E

1.600/900 - 444/250

40-36-33

55-51-48

319×840×840

24

30×950×950

4,2

RAV-RM1601UTP-E

2.130/1260 - 592/350

45-40-36

60-55-51

319×840×840

24

30×950×950

4,2

RAV-RM1401UTP-E

2.100/1230 - 583/341

44-38-34

59-53-49

319×840×840

24

30×950×950

4,2

Air Flow (H/L)

Sound pressure level (H-M-L)

Sound power level (H-M-L)

Dimensions (HxWxD)

Weight

Panel dimensions (HxWxD)

Panel weight

C = cooling mode H = heating mode

Page 30: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

4,7

SCOP MAX

The compact 4 way cassette is ideal for small commercial application where a compact efficient unit is needed.

Occupancy sensor switches off automatically the unit if nobody is in the room to save energy.*

DESIGN► Elegant and flat appearance► Fit within the T-bar of grid ceiling: 620mmX620mm

COMFORT► Individual setting of louver position: 3 different swing modes: standard, diagonally, opposite, turn around► 5 steps air flow

EASY INSTALLATION► Compact and thin chassis with only 256mm height► Built-in high-lift drain pump► Light-weight unit, for easy and quick installation

2,5kW-5,6kW

CAPACITY

-27°C/+52°C

OPERATION

30

*optional

Page 31: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Performance data with Super Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (600X600 Cassette)

RAV-GP561ATP-ERAV-RM561MUT-E

5,0

1,2-5,6

0,19 -1,56 -1,97

3,21

6,02

A+

291

5,6

0,9-7,0

0,16 - 1,60 - 2,36

3,50

4,30

A+

1.237

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Performance data with Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (600X600 Cassette)

RAV-GM301ATP-ERAV- RM301MUT-E

2,5

0,9 - 3,0

0,25 - 0,59 - 0,82

4,24

5,94

A+

147

3,4

0,8 - 4,5

0,17 - 0,76 - 1,40

4,47

4,70

A++

685

RAV-GM401ATP-ERAV- RM401MUT-E

3,6

0,9 - 4,0

0,18 - 0,90 - 2,00

4,00

5,76

A+

219

4,0

0,8 - 5,0

0,14 - 0,95 - 1,70

4,21

4,44

A+

851

RAV-GM561ATP-ERAV- RM561MUT-E

5,0

1,5 - 5,6

0,30 - 1,64 - 1,86

3,05

5,69

A+

307

5,3

1,5 - 6,3

0,30 - 1,47 - 2,40

3,61

4,37

A+

897

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Physical data indoor

m3/h - l/s

dB(A)

dB(A)

mm

kg

mm

kg

Indoor unit RAV- RM301MUT-E

640/440 - 177/122

38 - 36 - 30

53 - 51 - 45

256x575x575

15

12x620x620

2,5

RAV- RM401MUT-E

660/468 - 183/130

41 - 36 - 32

56 - 51 - 47

256x575x575

15

12x620x620

2,5

RAV- RM561MUT-E

798/546 - 221/152

44 - 39 - 35

59 - 54 - 50

256x575x575

15

12x620x620

2,5

Air Flow (H/L)

Sound pressure level (H-M-L)

Sound power level (H-M-L)

Dimensions (HxWxD)

Weight

Panel dimensions (HxWxD)

Panel weight

C = cooling mode H = heating mode

H-M-L = High - Medium - Low speed

31

RM_MUT COMPACT 4-WAY CASSETTE

Page 32: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

4,81

SCOP MAX

Whatever the shape of the room, this flexible model ensures a uniform temperature and air distribution for optimal end user comfort.

Airzone compatibility: multiple individual controlled rooms with only one indoor unit.

ADAPTABILITY► Up to 120Pa available pressure, thanks to DC fan motor► Flexible design allows the inlet air to be configured between the standard rear inlet design or as an alternative, from the underside of the unit. There is also a provision for a fresh air intake supply via a pre-punched knockout hole► Compact and thin chassis, measuring just 275mm in height

EASY INSTALLATION► Built-in high-lift drain pump► PC board panel easily accessible from the side of the unit► Optional air discharge spigot

5kW-16kW

CAPACITY

-27°C/+52°C

OPERATION

COMPATIBLE WITH

32

Page 33: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Performance data with Super Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Standard Duct)

RAV-GP561ATP-ERAV-RM561BTP-E

5,0

1,2-5,6

0,19 - 1,52 - 1,99

3,29

5,60

A+

312

5,6

0,9-7,4

0,16 - 1,61 - 2,76

3,48

4,24

A+

1.254

RAV-GP801AT-ERAV-RM801BTP-E

7,1

1,9 - 8,0

0,26 - 1,63 - 3,20

4,36

7,50

A++

331

8,0

1,3 - 11,3

0,20 - 1,85 - 3,55

4,32

4,81

A++

1.484

RAV-GP1101AT-ERAV-RM1101BTP-E

10,0

3,1 - 12,0

0,65 - 2,40 - 3,63

4,17

6,60

A++

530

11,2

2,6 - 13,0

0,47 - 2,73 - 3,38

4,10

4,24

A+

3.032

RAV-GP1401AT-ERAV-RM1401BTP-E

12,5

3,1 - 14,0

0,65 - 3,57 - 3,97

3,50

6,06

TBD

1.237

14,0

2,6 - 16,5

0,47 - 3,63 - 4,43

3,86

4,24

TBD

3.168

RAV-GP1101AT8-ERAV-RM1101BTP-E

10,0

2,6 - 12,0

0,66 - 2,58 - 4,01

3,88

5,70

A+

613

11,2

2,40 - 15,6

0,53 - 2,76 - 4,42

4,06

4,14

A+

3.644

RAV-GP1401AT8-ERAV-RM1401BTP-E

12,5

2,6 - 14,0

0,66 - 3,81 - 4,89

3,28

5,48

TBD

1.366

14,0

2,40 - 18,0

0,53 - 3,66 - 5,71

3,83

3,95

TBD

4.176

RAV-GP1601AT8-ERAV-RM1601BTP-E

14,0

2,6 - 16,0

0,66 - 4,49 - 6,50

3,12

5,36

TBD

1.566

16

2,4 - 19,0

0,53 - 4,57 - 6,96

3,50

3,93

TBD

4.271

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Performance data with Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Standard Duct)

RAV-GM561ATP-ERAV-RM561BTP-E

5,0

1,5 - 5,6

0,31 - 1,83 - 2,05

2,73

5,28

A

332

5,3

1,5 - 6,3

0,31 - 1,62 - 2,47

3,27

4,08

A+

960

RAV-GM801ATP-ERAV-RM801BTP-E

6,7

1,5 - 7,4

0,31 -2,38 - 2,76

2,82

5,20

A

451

7,7

1,5 - 9,0

0,31 -2,32 - 3,18

3,32

4,13

A+

1.728

RAV-GM901ATP-ERAV-GM901BTP-E

8,0

1,9 - 8,8

2,67

3,00

6,10

A++

459

9,0

1,6 - 9,9

2,65

3,40

4,60

A++

1.917

RAV-GM1101ATP-ERAV-RM1101BTP-E

9,5

3,0 - 11,2

0,60 - 2,99 - 4,50

3,18

5,28

A

629

11,2

3,0 - 13,0

0,60 - 2,99 - 4,00

3,75

4,19

A+

2.537

RAV-GM1101AT8P-ERAV-RM1101BTP-E

9,5

3,0 - 11,2

0,60 - 2,99 - 4,50

3,18

5,28

A

629

11,2

3,0 - 13,0

0,60 - 2,99 - 4,00

3,75

4,19

A+

2.537

RAV-GM1401ATP-ERAV-RM1401BTP-E

12,1

3,0 - 13,2

0,60 - 4,42 - 4,71

2,74

5,36

TBD

TBD

13,0

3,0 - 16,0

0,60 - 3,60 - 4,55

3,61

4,19

TBD

TBD

RAV-GM1401AT8P-ERAV-RM1401BTP-E

12,1

3,0 - 13,2

0,60 - 4,42 - 4,71

2,74

5,36

TBD

TBD

13,0

3,0 - 16,0

0,60 - 3,60 - 4,55

3,61

4,19

TBD

TBD

RAV-GM1601ATP-ERAV-RM1601BTP-E

14,0

3,0 - 16,0

5,13

2,73

5,3

TBD

1.584

16,0

3,0 - 18,0

4,69

3,41

3,9

TBD

2.872

RAV-GM1601AT8P-ERAV-RM1601BTP-E

14,0

3,0 - 16,0

5,13

2,73

5,3

TBD

1.584

16,0

3,0 - 18,0

4,69

3,41

3,9

TBD

2.872

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Physical data indoor

m3/h - l/s

dB(A)

dB(A)

mm

kg

Pa

Indoor unit RAV-RM561BTP-E

800/480 - 222/133

33-29-25

48-44-40

275x700x750

23

30/120

RAV-RM801BTP-E

1.200/720 - 333/200

34-30-26

49-45-41

275x1.000x750

30

30/120

RAV-GM901BTP-E

1.700/1.000 - 472/278

37-33-30

52-48-45

275x1.400x750

40

50/120

RAV-RM1101BTP-E

2.100/1.260 - 583/350

40-36-33

55-51-48

275x1.400x750

40

50/120

RAV-RM1601BTP-E

2.100/1.260 - 583/350

40-36-33

55-51-48

275x1.400x750

40

50/120

RAV-RM1401BTP-E

2.100/1.260 - 583/350

40-36-33

55-51-48

275x1.400x750

40

50/120

Air Flow (H/L)

Sound pressure level (H-M-L)*

Sound power level (H-M-L)*

Dimensions (HxWxD)

Weight

External static pressure (stand/upper limit)

C = cooling mode H = heating mode

* bottom air inlet

33

RM_BTP STANDARD DUCT

Page 34: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

4,6

SCOP MAX

Whether installed in a ceiling void or in a false ceiling, Toshiba’s slim duct offers the ultimate technology, with exceptional energy savings, high performance and easy installation.

Cleaned prefilter included compatible with rear or underside air suction.

ADAPTABILITY► Up to 50Pa available pressure with four steps set up► Easy to combine with different types of air diffusers► Flexible design, allows the inlet air to be configured between the standard rear inlet design or as an alternative, from the underside of the unit► There is also a provision for a fresh air intake supply via a pre-punched knockout hole

EASY INSTALLATION► Slimline design, with a height of just 21cm and a weight of 22kg, gives increased flexibility when designing and installing the system► Natural drain discharge or built-in drain pump to manage condensates

2,5kW-5,6kW

CAPACITY

-27°C/+52°C

OPERATION

34

Page 35: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Performance data with Super Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Slim duct)

RAV-GP561ATP-ERAV-RM561SDT-E

5,0

1,2-5,6

0,19 -1,56 - 1,98

3,21

5,77

A+

303

5,6

0,9-7,0

0,16 - 1,58 - 2,66

3,54

4,20

A+

1.266

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Performance data with Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Slim duct)

RAV-GM301ATP-ERAV- RM301SDT-E

2,5

0,9 - 3,0

0,25 - 0,56 - 0,82

4,46

6,29

A++

143

3,4

0,8 - 4,5

0,17 - 0,86 - 1,40

3,95

4,6

A++

907

RAV-GM401ATP-ERAV- RM401SDT-E

3,6

0,9 - 4,0

0,18 - 0,93 - 2,00

3,87

5,86

A+

227

4,0

0,8 - 5,0

0,14 - 0,97 - 1,70

4,12

4,01

A+

1.337

RAV-GM561ATP-ERAV-RM561SDT-E

5,0

1,5 - 5,6

0,32 - 1,91 - 2,75

2,62

5,14

A+

346

5,3

1,5 - 6,3

0,32 - 1,50 - 2,40

3,53

4,16

A+

1.517

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Physical data indoor

m3/h - l/s

dB(A)

dB(A)

mm

kg

Pa

Indoor unit RAV- RM301SDT-E

660/480 - 183/133

39-36-33

51-48-44

210x845x645

22

30(45-5)

RAV- RM401SDT-E

690/522 - 192/145

39-36-33

52-48-44

210x845x645

22

30(45-5)

RAV-RM561SDT-E

780/582 - 217/162

45-40-36

55-53-48

210x845x645

22

29(44-4)

Air Flow (H/L)

Sound pressure level (H-M-L)*

Sound power level (H-M-L)

Dimensions (HxWxD)

Weight

External static pressure standard (Upper-Lower)

C = cooling mode H = heating mode

* bottom air inlet

35

RM_SDT SLIM DUCT

Page 36: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

3,51

SCOP MAX

Toshiba’s high static pressure ducts are specifically designed for large open spaces, due to their impressive air flow characteristics.

The DTP high static duct is compatible with textile duct diffusion system to blow the air smoothly all over the treated room.

COMFORT► 3-speed DC fan motor provides the correct air flow, whilst maximizing energy savings► Compatible with metal or textile duct

ADAPTABILITY► Designed to be lightweight, making the installation process quick and easy► With 7 step settings the static pressure of the system can range from 50 to 250Pa► Up to 5.600m3/h air flow to blow the air into large rooms

EASY INSTALLATION► Electronic components accessible from outside the unit► Air filter and drain pump available as an option

20kW-27kW-

CAPACITY

-27°C/+52°C

OPERATION

36

Page 37: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Performance data with Big DI Inverter

kW

kW

kW

W/W

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (High Static duct)

RAV-GM2241AT8-ERAV-RM2241DTP-E

19,0

4,6 - 22,4

1,27 - 5,86 - 9,05

3,24

4,62

TBD

2.468

22,4

4,6 - 25,0

1,27 - 5,71 - 10,15

3,92

3,51

TBD

7.174

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

RAV-GM2801AT8-ERAV-RM2801DTP-E

22,5

4,6 - 27,0

1,27 - 7,98 - 11,87

2,82

4,61

TBD

2.928

27,0

4,6 - 31,5

1,27 - 7,52 - 13,83

3,59

3,44

TBD

8.136

Physical data indoor

m3/h - l/s

dB(A)

dB(A)

mm

kg

Pa

Indoor unit RAV-RM2241DTP-E

3.800 - 1.055

44

79

448x1400x900

97

250/150/50,0

RAV-RM2801DTP-E

4.800 - 1.333

46

81

448x1400x900

97

250/150/50,0

Air Flow

Sound pressure level (back)

Sound power level (back)

Dimensions (HxWxD)

Weight

Upper limit/middle/standard

C = cooling mode H = heating mode

37

RM_DTP HIGH STATIC DUCT

Page 38: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

4,41

SCOP MAX

Toshiba floor standing unit combines important air flow, wide air diffusion and simplified installation to cool and heat large rooms.

Embedded leak detector linked to safety ventilation to facilitate the integration of the product in every kind of projects.

WIDE ADAPTABILITY► Broad capacity lineup from 2 to 6HP► Connectable in monosplit or twin mode

COMFORT► Wide air flow to cool and heat large areas► Horizontal and vertical louvers for optimum air distribution

EASY INSTALLATION► Directly positioned on the floor to simplify installation► Plug and play product with embedded controller

5kW-16kW

CAPACITY

-27°C/+52°C

OPERATION

38

Page 39: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Performance data with Super Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Standard Duct)

RAV-GP561ATP-ERAV-RM561FT-EN

5,0

1,2-5,6

0,19-1,42-2,0

3,51

5,75

A+

304

5,6

0,9-7,0

0,16-1,65-2,80

3,39

4,2

A+

1.266

RAV-GP801AT-ERAV-RM801FT-EN

7,1

1,9 - 8,0

0,26-2,04-3,32

3,48

6,24

A++

398

8,0

1,3 - 11,3

0,2-2,37-3,75

3,38

4,41

A+

1.618

RAV-GP1101AT-ERAV-RM1101FT-EN

10,0

3,1 - 12,0

0,6-2,39-3,65

4,18

6,67

A++

524

11,2

2,6 - 13,0

0,42-2,76-3,85

4,06

4,37

A+

2.942

RAV-GP1601AT8-ERAV-RM1601FT-EN

14,0

2,6 - 16,0

0,66-4,39-6,5

3,19

5,55

TBD

1.513

16

2,4 - 19,0

0,53-4,83-6,96

3,31

3,96

TBD

4.238

RAV-GP1401AT8-ERAV-RM1401FT-EN

12,5

2,6 - 14,0

0,66-3,61-4,91

3,46

5,65

TBD

1.326

14,0

2,40 - 18,0

0,53-3,81-5,95

3,67

4,00

TBD

4.130

RAV-GP1101AT8-ERAV-RM1101FT-EN

10,0

2,6 - 12,0

0,66-2,46-4,1

4,07

5,86

A+

597

11,2

2,4 - 14,0

0,53-2,77-4,8

4,04

4,00

A+

3.774

RAV-GP1401AT-ERAV-RM1401FT-EN

12,5

3,1 - 14,0

0,6-3,52-4,07

3,55

6,1

TBD

1.229

14,0

2,6 - 16,5

0,42-3,97-4,61

3,53

4,35

TBD

3.086

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Performance data with Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Standard Duct)

RAV-GM561ATP-ERAV-RM561FT-EN/ES

5,0

1,5 - 5,6

0,30-1,79-2,34

2,79

5,15

A

340

5,3

1,5 - 6,3

0,30-1,72-2,47

3,08

4

A+

980

RAV-GM801ATP-ERAV-RM801FT-EN

6,7

1,5 - 7,4

0,31-3,18-3,31

2,11

4,89

B

479

7,7

1,5 - 9,0

0,31-3,20-3,45

2,41

3,81

A

1.727

RAV-GM1101ATP-ERAV-RM1101FT-EN

9,5

3,0 - 11,2

0,60-3,06-4,30

3,1

5,16

A

644

11,2

3,0 - 13,0

0,60-3,19-4,50

3,51

3,92

A

2.711

RAV-GM1101AT8P-ERAV-RM1101FT-EN

9,5

3,0 - 11,2

0,60-3,06-4,30

3,1

5,16

A

644

11,2

3,0 - 13,0

0,60-3,19-4,50

3,51

3,92

A

2.711

RAV-GM1401ATP-ERAV-RM1401FT-EN

12,1

3,0 - 13,2

0,60-4,71-4,83

2,57

4,86

TBD

1.492

13

3,0 - 16,0

0,60-4,01-4,80

3,24

3,9

TBD

2.727

RAV-GM1401AT8P-ERAV-RM1401FT-EN

12,1

3,0 - 13,2

0,60-4,71-4,83

2,57

4,86

TBD

1.492

13

3,0 - 16,0

0,60-4,01-4,80

3,24

3,9

TBD

2.727

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Physical data indoor

m3/h - l/s

dB(A)

dB(A)

mm

kg

Pa

Indoor unit RAV-RM561FT-EN/ES

820/600 - 228/167

46-42-38

60-56-52

1.750x600x210

44

TBD

RAV-RM801FT-EN

930/640 - 258/178

50-45-41

64-60-54

1.750x600x210

45

TBD

RAV-RM1101FT-EN

1.660/1.190 - 461/331

51-46-41

65-61-55

1.750x600x390

59

TBD

RAV-RM1401FT-EN

1.760/1.350 - 489/375

53-48-45

67-62-59

1.750x600x390

59

TBD

RAV-RM1601FT-EN

1.760/1.350 - 489/375

53-48-45

67-62-59

1.750x600x390

59

TBD

Air Flow (H/L)

Sound pressure level (H-M-L)*

Sound power level (H-M-L)*

Dimensions (HxWxD)

Weight

External static pressure(stand/upper limit)

C = cooling mode H = heating mode

39

RM_FT FLOOR STANDING

Page 40: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

40

5,05

SCOP MAX

The simple, yet elegant design creates a pleasant and relaxing environment, quickly conditioning the room air to the desired temperature.

The airflow angle is automatically set to the most suitable setting according to the cooling or heating needs.

COMFORT► Automatic louver control for all year-round comfort and efficiency► Low noise levels, thanks to high diameter fan and DC motor

RELIABILITY► Self-cleaning function enables the air flow to remain constant and fresh and reduces the frequency of service visits

EASY TO INSTALL & TO MAINTAIN► This design represents the best possible solution, where there is a lack of space or absence of a ceiling void

ADAPTABILITY► Anti-bacterial drain points available as an option► Connecting kit available as an option for external I/O without local relay preparation

3,6kW-16kW

CAPACITY

-27°C/+52°C

OPERATION

Page 41: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

41

RM_CTP CEILING

Performance data with Super Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Ceiling)

RAV-GP561ATP-ERAV-RM561CTP-E

5,0

1,2-5,6

0,19-1,37-1,98

3,65

6,76

A++

259

5,6

0,9-7,4

0,16-1,39-2,67

4,03

4,70

A++

1.130

RAV-GP801AT-ERAV-RM801CTP-E

7,1

1,9 - 8,0

0,26-1,60-3,17

4,44

7,95

A++

312

8,0

1,3 - 11,3

0,20-1,80-3,55

4,44

5,05

A++

1.412

RAV-GP1101AT-ERAV-RM1101CTP-E

10,0

3,1 - 12,0

0,55-2,23-3,45

4,48

8,23

A++

425

11,2

2,6 - 13,0

0,41-2,38-3,09

4,71

4,72

A++

2.726

RAV-GP1601AT8-ERAV-RM1601CTP-E

14,0

2,6 - 16,0

0,66 - 4,60 - 6,33

3,04

6,00

TBD

1400

16

2,4 - 19,0

0,53 - 4,30 - 6,96

3,72

3,93

TBD

4.003

RAV-GP1401AT8-ERAV-RM1401CTP-E

12,5

2,6 - 14,0

0,66 - 3,68 - 4,85

3,40

6,30

TBD

1190

14,0

2,40 - 18,0

0,53 - 3,48 - 5,95

4,02

3,94

TBD

3.931

RAV-GP1101AT8-ERAV-RM1101CTP-E

10,0

2,6 - 12,0

0,66 - 2,56 - 3,81

3,91

6,61

A++

529

11,2

2,4 - 14,0

0,53 - 2,51 - 4,26

4,46

4,21

A+

3.854

RAV-GP1401AT-ERAV-RM1401CTP-E

12,5

3,1 - 14,0

0,55-3,58-3,97

3,49

7,58

TBD

989

14,0

2,6 - 16,5

0,41-3,59-4,40

3,90

4,71

TBD

2.852

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Performance data with Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (Ceiling)

RAV-GM401ATP-ERAV-RM401CTP-E

3,6

0,9 - 4,0

0,18 - 0,83 - 2,00

4,34

6,34

A++

199

4,0

0,8 - 5,0

0,14 - 0,78 - 1,70

5,13

5,1

A+++

741

RAV-GM561ATP-ERAV-RM561CTP-E

5,0

1,5 - 5,6

0,29-1,61-1.95

3,11

5,5

A

318

5,3

1,5 - 6,3

0,29-1,36-2,40

3,90

4,32

A+

908

RAV-GM901ATP-ERAV-GM901CTP-E

8,0

1,9 - 8,8

2,58

3,10

6,10

A++

459

9,0

1,6 - 9,9

2,65

3,40

4,60

A++

1.917

RAV-GM801ATP-ERAV-RM801CTP-E

6,9

1,5 - 7,4

0,29-2,38-2,76

2,90

5,62

A+

429

7,7

1,5 - 9,0

0,29-2,13-3,20

3,62

4,11

A+

1.697

RAV-GM1101ATP-ERAV-RM1101CTP-E

9,5

3,0 - 11,2

0,60-2,95-4,10

3,22

5,86

A+

567

11,2

3,0 - 12,5

0,60-2,94-4,10

3,81

4,27

A+

2.490

RAV-GM1101AT8P-ERAV-RM1101CTP-E

9,5

3,0 - 11,2

0,60-2,95-4,10

3,22

5,86

A+

604

11,2

3,0 - 12,5

0,60-2,94-4,10

3,81

4,27

A+

2.490

RAV-GM1601ATP-ERAV-RM1601CTP-E

14,0

3,0 - 16,0

4,65

3,01

5,9

TBD

1.423

16,0

3,0 - 18,0

4,69

3,9

4,35

TBD

2.732

RAV-GM1601AT8P-ERAV-RM1601CTP-E

14,0

3,0 - 16,0

4,65

3,01

5,9

TBD

1.423

16,0

3,0 - 18,0

4,69

3,9

4,35

TBD

2.732

RAV-GM1401ATP-ERAV-RM1401CTP-E

12,1

3,0 - 13,2

0,60-4,42-4.71

2,74

5,36

TBD

TBD

13,0

3,0 - 16,0

0,60-3,48-4,60

3,73

4,19

TBD

TBD

RAV-GM1401AT8P-ERAV-RM1401CTP-E

12,1

3,0 - 13,2

0,60-4,42-4,71

2,74

5,36

TBD

TBD

13,0

3,0 - 16,0

0,60-3,48-4,60

3,73

4,19

TBD

TBD

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

Physical data indoor

m3/h - l/s

dB(A)

dB(A)

mm

kg

Indoor unit RAV-RM401CTP-E

900/540 - 250/150

37-35-28

52-50-43

235x950x690

23

RAV-RM561CTP-E

900/540 - 250/150

37-35-28

52-50-43

235x950x690

23

RAV-RM801CTP-E

1.410/750 - 392/208

41-36-29

56-51-44

235x1.270x690

29

RAV-GM901CTP-E

1.600/900 - 444/250

42-38-30

57-53-45

235x1.586x690

37

RAV-RM1101CTP-E

1.860/1.020 - 517/283

44-38-32

59-53-47

235x1.586x690

37

RAV-RM1601CTP-E

2.100/1.260 - 583/350

40-36-33

55-51-48

275x1.400x750

40

RAV-RM1401CTP-E

2.040/1.200 - 567/333

46-41-35

61-56-50

235x1.586x690

37

Air Flow (H/L)

Sound pressure level (H-M-L)

Sound power level (H)

Dimensions (HxWxD)

Weight

C = cooling mode H = heating mode

Page 42: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

4,41

SCOP MAX

Compact, quiet with an attractive design, this high wall is suitable for every kind of project in new construction or refurbishment.

Comfort sleep function adjusts automatically the room temperature and the fan speed.

COMFORT► Auto louver mode allows optimum and uniform air distribution

CONTROL► Wireless remote control with pre-set functions accessible with dedicated buttons: hi-power mode, quiet mode, comfort sleep, eco-mode

HEALTHY► Self-cleaning feature to prevent mould formation on the heat exchanger coils

0,9-12kW

CAPACITY

-20°C/+46°C

OPERATION

42

Page 43: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Performance data with Super Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (High-Wall)

RAV-GP561ATP-ERAV-RM561KRTP-E

5,0

1,2 - 5,6

0,19 - 1,43 -1,98

3,50

7,59

A++

230

5,6

0,9 - 7,3

0,16 - 1,39 - 2,67

4,03

4,17

A+

1.274

RAV-GP1101AT-ERAV-GM1101KRTP-E

10,0

3.1- 12.0

0,55-2,77-3,90

3,61

7,2

A++

486

11,2

2,6- 13,0

0,52-3,13-4,40

3,58

4,41

A+

2.920

10,0

2,6 - 12,0

2,86

3,50

6,35

A++

551

11,2

2,4 - 13,0

3,25

3,45

4,21

A+

3.591

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

RAV-GP1101AT8-ERAV-GM1101KRTP-E

RAV-GP801ATP-ERAV-RM801KRTP-E

7,1

1,9 - 8,0

0,26 - 2,06 - 3,17

3,45

7,34

A++

338

8,0

1,3 - 11,3

0,20 - 2,25 - 3,50

3,56

4,13

A+

1.725

Performance data with Digital Inverter

kW

kW

kW

kWh/a

kW

kW

kW

W/W

kWh/a

C

C

C

H

H

H

Outdoor unitIndoor unit (High-Wall)

RAV-GM301ATP-ERAV-RM301KRTP-E

2,5

0,9 - 3,0

0,25 - 0,61 - 0,82

4,10

6,36

A++

138

3,4

0,8 - 4,5

0,17 - 0,85 - 1,40

4,00

4,10

A+

887

Cooling capacity

Cooling range (min. - max.)

Power input (min. - rated - max.)

EER

SEER

Energy efficiency class

Seasonal electricity consumption

Heating capacity

Heating range (min. - max.)

Power input (min. - rated - max.)

COP

SCOP

Energy efficiency class

Seasonal electricity consumption

RAV-GM401ATP-ERAV-RM401KRTP-E

3,6

0,9 - 4,0

0,18 - 1,13 - 2,00

3,19

6,12

A++

206

4,0

0,8 - 5,0

0,14 - 1,12 - 1,70

3,57

4,22

A+

895

RAV-GM561ATP-ERAV-RM561KRTP-E

5,0

1,5 - 5,6

0,30 - 1,66 - 1,86

3,01

6,19

A++

383

5,3

1,5 - 6,3

0,30 - 1,55 - 2,40

3,42

4,00

A+

980

RAV-GM801ATP-ERAV-RM801KRTP-E

6,7

1,5 - 8,0

0,31- 2,44 - 2,85

2,75

5,73

A+

409

7,7

1,5 - 9,0

0,31 - 2,61 - 3,30

2,95

4,01

A+

1.780

RAV-GM901ATP-ERAV-GM901KRTP-E

8,0

1,9 - 8,8

2,67

3,00

6,10

A++

459

9,0

1,6 - 9,9

2,9

3,10

4,10

A+

2.151

RAV-GM1101ATP-ERAV-GM1101KRTP-E

9,5

3,0 - 11,2

0,60 - 2,97 - 4,30

3,20

6,10

A++

545

11,2

3,0 - 13,0

0,60 - 3,47 - 4,70

3,23

4,20

A+

2.665

RAV-GM1101AT8P-ERAV-GM1101KRTP-E

9,5

3,0 - 11,2

0,60 - 2,97 - 4,30

3,20

6,10

A++

545

11,2

3,0 - 13,0

0,60 - 3,47 - 4,70

3,23

4,20

A+

2.664

Physical data indoor

m3/h - l/s

dB(A)

dB(A)

mm

kg

C

C

C

Indoor unit RAV-RM301KRTP-E

670/450 - 186/125

40-34-29

55-49-44

293x798x230

10

RAV-RM401KRTP-E

700/450 - 229/125

41-36-30

56-51-45

293x798x230

10

RAV-RM561KRTP-E

960/680 - 266/189

42-39-35

57-54-50

320x1.050x250

14

RAV-GM901KRTP-E

1.180/ 680 - 328/189

47-41-35

62-56-50

320x1.050x250

14

RAV-GM1101KRTP-E

1.610/1.180 - 447/328

49-45-41

64-60-56

348x1.200x280

19

RAV-RM801KRTP-E

1.040/680 - 289/189

45-41-35

60-56-50

320x1.050x250

14

Air Flow (H/L)

Sound pressure level (H-M-L)

Sound power level (H-M-L)

Dimensions (HxWxD)

Weight

C = cooling mode H = heating mode

43

RM_KRTP HIGH-WALL

Page 44: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

5,05

SCOP MAX

Connect 2 indoor units on the same system to satisfy the cooling and heating requirements of larger area.

Toshiba RAV simplistic piping design allows multiple indoor units to be connected via a simple branching methodology.

COMFORT► Precise air flow control, accurately controls the distribution of the air regardless of the room size

ADAPTABILITY► Twin configuration with up to 50m piping length► Compatible with every type of LC indoor units: 4–way cassette, duct, high-wall and ceiling

CONTROL► One user-friendly controller for all the indoor units to simplify the control

9,5kW-14kW

CAPACITY

-27°C/+52°C

OPERATION

44

Page 45: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Twin split DI - Cooling

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

9,59,5

12,012,014,014,09,59,59,59,5

12,112,114,014,09,59,59,59,5

12,112,114,014,09,59,5

12,112,114,014,09,59,5

12,112,1

3,0 - 11,23,0 - 11,23,0 - 13,23,0 - 13,23,0 - 16,03,0 - 16,03,0 - 11,23,0 - 11,23,0 - 11,23,0 - 11,23,0 - 13,23,0 - 13,23,0 - 16,03,0 - 16,03,0 - 11,2 3,0 - 11,2 3,0 - 11,2 3,0 - 11,2 3,0 - 13,23,0 - 13,23,0 - 16,03,0 - 16,03,0 - 11,23,0 - 11,23,0 - 13,23,0 - 13,23,0 - 16,03,0 - 16,03,0 - 11,23,0 - 11,23,0 - 13,23,0 - 13,2

GM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-E

Indoor unitRAV-

RM561UTP-ERM561UTP-ERM801UTP-ERM801UTP-ERM801UTP-ERM801UTP-ERM561MUT-ERM561MUT-ERM561BTP-ERM561BTP-ERM801BTP-ERM801BTP-ERM801BTP-ERM801BTP-ERM561SDT-ERM561SDT-ERM561CTP-ERM561CTP-ERM801CTP-ERM801CTP-ERM801CTP-ERM801CTP-ERM561KRTP-ERM561KRTP-ERM801KRTP-ERM801KRTP-ERM801KRTP-ERM801KRTP-ERM561FT-EN/ESRM561FT-EN/ESRM801FT-EN/ESRM801FT-EN/ESRM801FT-EN/ESRM801FT-EN/ES

HP

4455664444556644445566445566445566

Power inputkW

2,872,874,294,294,494,493,003,002,992,994,424,425,135,133,033,032,952,954,424,424,654,652,982,984,714,715,095,093,063,064,714,71

EER

3,313,312,802,803,123,123,173,173,183,182,742,742,732,733,143,143,223,222,742,743,013,013,193,192,572,572,752,753,103,102,572,57

SEER

5,945,945,715,716,36,35,55,5

5,285,285,365,365,305,305,325,325,865,865,365,365,905,905,325,325,245,245,15,1

5,165,164,864,86

Energyclass

A+A+A+A+

TBDTBD

AAAA

TBDTBDTBDTBD

AA

A+A+

TBDTBDTBDTBD

AA

TBDTBDTBDTBD

AA

TBDTBD

4-way cassette

Compact4-way cassette

Ducted

Slim duct

Ceiling

High-wall

Floor standing

Twin split DI - Heating

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

11,211,213,013,016,016,011,211,211,211,213,013,016,016,011,211,211,211,213,013,016,016,011,211,213,013,016,016,011,211,213,013,0

3,0 - 13,03,0 - 13,0 3,0 - 16,0 3,0 - 16,03,0 - 18,03,0 - 18,03,0 - 13,03,0 - 13,03,0 - 13,03,0 - 13,0 3,0 - 16,0 3,0 - 16,03,0 - 18,03,0 - 18,03,0 - 13,03,0 - 13,03,0 - 13,03,0 - 13,0 3,0 - 16,0 3,0 - 16,03,0 - 18,03,0 - 18,03,0 - 13,03,0 - 13,0 3,0 - 16,0 3,0 - 16,03,0 - 18,03,0 - 18,03,0 - 13,03,0 - 13,03,0 - 16,03,0 - 16,0

GM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-E

Indoor unitRAV-

RM561UTP-ERM561UTP-ERM801UTP-ERM801UTP-ERM801UTP-ERM801UTP-ERM561MUT-ERM561MUT-ERM561BTP-ERM561BTP-ERM801BTP-ERM801BTP-ERM801BTP-ERM801BTP-ERM561SDT-ERM561SDT-ERM561CTP-ERM561CTP-ERM801CTP-ERM801CTP-ERM801CTP-ERM801CTP-ERM561KRTP-ERM561KRTP-ERM801KRTP-ERM801KRTP-ERM801KRTP-ERM801KRTP-ERM561FT-EN/ESRM561FT-EN/ESRM801FT-EN/ESRM801FT-EN/ESRM801FT-EN/ESRM801FT-EN/ES

HP

4455664444556644445566445566445566

Power inputkW

2,932,933,463,464,434,433,263,262,992,993,603,604,694,692,992,992,942,943,483,484,614,612,992,993,863,864,984,983,193,194,014,01

COP

3,823,823,763,763,613,613,443,443,753,753,613,613,413,413,753,753,813,813,743,743,473,473,753,753,373,373,213,213,513,513,243,24

SCOP

4,284,284,294,294,354,354,024,024,224,224,214,213,473,474,194,194,284,284,194,194,104,104,194,194,194,19

44

3,923,923,903,9

Energyclass

A+A+A+A+

TBDTBDA+A+A+A+

TBDTBDTBDTBDA+A+A+A+

TBDTBDTBDTBDA+A+

TBDTBDTBDTBDA+A

TBDTBD

4-way cassette

Compact4-way cassette

Ducted

Slim duct

Ceiling

High-wall

Floor standing

SDI-DI TWIN

Page 46: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

46

Triple split SDI - Cooling

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

1414141414

141414141414

14

3,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,0

3,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,0

3,0 - 16,0

GM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-E

Indoor unitRAV-

RM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-ERM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-E

HP

66666666666666

Power inputkW

4,494,965,134,984,65

5,094,494,965,134,984,65

5,09

EER

3,122,822,732,813,01

2,753,122,822,732,813,01

2,75

SEER

6,35,15,35,15,9

5,16,35,15,35,15,9

5,1

Energyclass

TBDTBDTBDTBDTBD

TBDTBDTBDTBDTBDTBD

TBD

4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall

Triple split SDI - Heating

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

1616161616

161616161616

16

3,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,0

3,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,0

3,0 - 18,0

GM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-E

Indoor unitRAV-

RM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-ERM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-E

HP

66666666666666

Power inputkW

4,434,694,694,694,61

4,984,434,694,694,694,61

4,8

COP

3,613,413,413,413,47

3,213,613,413,413,413,47

3,21

SCOP

4,354

3,94

4,1

44,35

43,94

4,1

4

Energyclass

TBDTBDTBDTBDTBD

TBDTBDTBDTBDTBDTBD

TBD

4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall

Page 47: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

SDI-DI TWIN

Twin split SDI - Cooling

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

10,012,510,012,510,012,514,07,1

10,010,010,012,510,012,514,07,1

10,010,07,1

10,012,510,012,514,010,012,510,012,514,010,012.510,012,314,0

3,1-12,03,1-14,03,1-12,03,1-14,0

2,6 - 12,0 2,6 - 14,0 2,6 - 16,0

1,9-8,03,1-12,0

2,6 - 12,03,1-12,03,1-14,0

2,6 - 12,0 2,6 - 14,0 2,6 - 16,0

1,9-8,03,1-12,0

2,6 - 12,01,9-8,0

3,1-12,03,1-14,0

2,6 - 12,0 2,6 - 14,0 2,6 - 16,03,1-12,0

3,1 - 14,02,6 - 12,02,6 - 14,02,6 - 16,03,1-12,03,1-14,0

2,6 - 12,0 2,6 - 13,52,6 - 16,0

GP1101AT-EGP1401AT-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP801AT-EGP1101AT-EGP1101AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP801AT-EGP1101AT-EGP1101AT8-EGP801AT-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-E

Indoor unitRAV-

GM561UT-EGM801UT-ERM561UTP-ERM801UTP-ERM561UTP-ERM801UTP-ERM801UTP-ERM401MUT-ERM561MUT-ERM561MUT-ERM561BTP-ERM801BTP-ERM561BTP-ERM801BTP-ERM801BTP-ERM401SDT-ERM561SDT-ERM561SDT-ERM401CTP-ERM561CTP-ERM801CTP-ERM561CTP-ERM801CTP-ERM801CTP-ERM561FT-ERM801FT-ERM561FT-ERM801FT-ERM801FT-ERM561KRTP-ERM801KRTP-ERM561KRTP-ERM801KRTP-ERM801KRTP-E

HP

4545456344454563443454564545645456

Power inputkW

1,92,912,133,162,323,424,341,732,392,602,403,572,583,814,491,872,562,781,602,233,582,563,684,602,393,522,463,614,392,443,552,613,734,65

EER

5,264,3

4,693,964,313,653,234,104,183,854,173,503,883,283,123,803,913,604,444,483,493,913,403,044,183,554,073,463,194,1

3,453,833,303,01

SEER

8,648,198,578,147,067,066,767,807,706,166,746,275,815,645,506,506,655,607,827,977,346,546,175,896,676,075,885,655,558,156,696,356,105,88

Energyclass

A++TBDA++TBDA++TBDTBDA++A++A++A++TBDA+

TBDTBDA++A++A+

A++A++TBDA++TBDTBDA++TBDA+

TBDTBDA++TBDA++TBDTBD

Smart4-way cassette

4-way cassette

Compact 4-way cassette

Ducted

Slim duct

Ceiling

Floor standing

High-wall

Twin split SDI - Heating

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

11,214,011,214,011,214,016,08,0

11,211,211,214,011,214,016,08,0

11,211,28,0

11,214,0 11,214,016,011,214,011,214,016,011,214,011,214,016,0

2,6-13,02,6-16,52,6-13,02,6-16,5

2,4 - 15,62,4 - 18,02,4 - 19,01,3-11,32,6-13,0

2,4 - 14,02,6-13,02,6-16,5

2,4 - 15,62,4 - 18,02,4 - 19,01,3-11,32,6-13,0

2,4 - 14,01,3-11,32,6-13,02,6-16,5

2,4 - 14,02,4 - 18,02,4 - 19,02,6 - 13,02,6 - 16,52,4 - 14,02,4 - 18,02,4 - 19,02,6-13,02,6-16,5

2,4 - 14,02,4 - 18,02,4 - 19,0

GP1101AT-EGP1401AT-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP801AT-EGP1101AT-EGP1101AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP801AT-EGP1101AT-EGP1101AT8-EGP801AT-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-E

Indoor unitRAV-

GM561UT-EGM801UT-ERM561UTP-ERM801UTP-ERM561UTP-ERM801UTP-ERM801UTP-ERM401MUT-ERM561MUT-ERM561MUT-ERM561BTP-ERM801BTP-ERM561BTP-ERM801BTP-ERM801BTP-ERM401SDT-ERM561SDT-ERM561SDT-ERM401CTP-ERM561CTP-ERM801CTP-ERM561CTP-ERM801CTP-ERM801CTP-ERM561FT-ERM801FT-ERM561FT-ERM801FT-ERM801FT-ERM561KRTP-ERM801KRTP-ERM561KRTP-ERM801KRTP-ERM801KRTP-E

HP

4545456344454563443454564545645456

Power inputkW

2,183,042,343,212,413,414,281,822,672,992,733,632,763,664,571,822,672,661,802,383,592,513,484,302,763,972,773,814,832,733,662,663,784,87

COP

5,144,614,794,364,654,113,744,404,193,744,103,864,063,833,504,404,194,214,444,713,904,464,023,724,063,534,043,673,314,103,664,213,703,29

SCOP

5,004,974,734,724,364,364,364,864,403,934,264,254,163,963,944,514,003,845,054,714,704,214,194,194,384,354,014,003,964,054,374,144,114,08

Energyclass

A++TBDA++TBDA+

TBDTBDA++A+A

A+TBD

ATBDTBDA+A+A

A++A++TBDA+

TBDTBDA+

TBDA+

TBDTBDA+

TBDA+

TBDTBD

Smart4-way cassette

4-way cassette

Compact 4-way cassette

Ducted

Slim duct

Ceiling

Floor standing

High-wall

Page 48: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

48

Triple split SDI - Cooling

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

14141414141414

2,6 - 16,02,6 - 16,02,6 - 16,02,6 - 16,02,6 - 16,02,6 - 16,02,6 - 16,0

GP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-E

Indoor unitRAV-

RM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-E

HP

6666666

Power inputkW

4,344,244,494,304,604,394,65

EER

3,233,303,123,263,043,193,01

SEER

6,716,095,425,985,955,555,82

Energyclass

-------

4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall

Triple split SDI - Heating

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

16161616161616

2,4 - 19,0 2,4 - 19,0 2,4 - 19,0 2,4 - 19,0 2,4 - 19,0 2,4 - 19,0 2,4 - 19,0

GP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-E

Indoor unitRAV-

RM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-E

HP

6666666

Power inputkW

4,284,564,574,574,304,834,87

COP

3,743,513,503,503.723,313,29

SCOP

4,364,133,944,074,193,964,08

Energyclass

-------

4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall

Twin split Big-DI - Cooling

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

20,023,520,023,520,023,520,023,5

4,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,0

GM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-E

Indoor unitRAV-

RM1101UTP-ERM1401UTP-ERM1101BTP-ERM1401BTP-ERM1101FT-ENRM1401FT-ENRM1101CTP-ERM1401CTP-E

HP

8108

108

108

10

Power inputkW

5,567,836,178,876,178,876,178,97

EER

3,603,003,242,653,242,653,242,62

SEER

6,536,215,034,925,084,875,675,16

4-way cassette

Ducted

Floor standing

Ceiling

Twin split Big-DI - Heating

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

22,427,022,427,022,427,022,427,0

4,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,5

GM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-E

Indoor unitRAV-

RM1101UTP-ERM1401UTP-ERM1101BTP-ERM1401BTP-ERM1101FT-ENRM1401FT-ENRM1101CTP-ERM1401CTP-E

HP

8108

108

108

10

Power inputkW

5,307,105,577,465,638,215,717,56

COP

4,233,804,023,623,983,293,923,57

SCOP

4,053,903,723,643,603,573,793,65

4-way cassette

Ducted

Floor standing

Ceiling

Page 49: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

SDI-DI TWIN

49

Triple split Big-DI - Cooling

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

20,023,520,023,520,023,520,0

23,5

20,0

23,5

4,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,04,6 - 22,4

4,6 - 27,0

4,6 - 22,4

4,6 - 27,0

GM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-E

GM2801AT8-E

GM2241AT8-EGM2801AT8-E

Indoor unitRAV-

RM801UTP-ERM801UTP-ERM801BTP-ERM801BTP-ERM801CTP-ERM801CTP-ERM801FT-EN

RM801FT-ENRM-801KRTP-E

RM-801KRTP-E

HP

8108

108

108

10

810

Power inputkW

5,567,836,178,876,178,876,17

8,87

6,67

9,22

EER

3,603,003,242,653,242,653,24

2,65

3,00

2,55

SEER

6,576,245,225,095,595,165,094,94

5,58

5,30

4-way cassette

Ducted

Ceiling

Floor standing

High-wall

Triple split Big-DI - Heating

Indoor unit model Outdoor unitRAV-

capacity nominal-kW min-max-kW

22,427,022,427,022,427,022,427,0

22,4

27,0

4,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,5

4,6 - 25,0

4,6 - 31,5

GM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-E

GM2801AT8-E

GM2241AT8-EGM2801AT8-E

Indoor unitRAV-

RM801UTP-ERM801UTP-ERM801BTP-ERM801BTP-ERM801CTP-ERM801CTP-ERM801FT-EN

RM801FT-ENRM-801KRTP-E

RM-801KRTP-E

HP

8108

108

108

10

810

Power inputkW

5,307,105,577,465,717,565,63

8,21

6,12

7,65

COP

4,233,804,023,623,923,573,98

3,29

3,66

3,53

SCOP

4,053,913,743,653,793,653,60

3,58

3,76

3,63

4-way cassette

Ducted

Ceiling

Floor standing

High-wall

Page 50: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Up to 5.000m3/h

MAX AIR FLOW

The DX kit enables connection of a third-party party air handling unit (with DX coil) to Toshiba LC outdoor units.

Input/output signal available:• Operation output• AC fan motor output• Alarm output• External On/Off input• Safety-cut output

FLEXIBILITY► Compatible with the majority of air handling units with a DX coil fitted inside (capacity ranges from 4,6 to 27kW)► Can operate in both heating and cooling modes, depending on end user requirements

CONTROL► Control achieved using a standard Toshiba remote controller► Algorithm based on air suction temperature

EASY TO INSTALL & MAINTAIN► Capacity set by DN code adjustment during installation► Extended 5 meters sensor leads pre-fitted to improve installation time and flexibility► Relay isolated inputs to prevent accidental wiring errors, damaging the PCB

4,1kW-27kW

CAPACITY

-27°C/+52°C

OPERATION

50

Page 51: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

DX Kit Performances

kW

kW

kW

kW

m3/h

dm3

DX Controller unitOutdoor Unit Cooling CapacityRANGE

DXC0102 HP

RAV-SM564ATP-ERAV-SP564ATP-E

RAV-

DISDI

4,1 - 5,3 - 5,6

4,1 - 5,3 - 5,6

4,6 - 5,6 - 6,3

4,6 - 5,6 - 7,4

720-900-1.080

0,8 - 1,1

DXC0103 HP

RAV-SM804ATP-ERAV-SP804ATP-E

5,4 - 7,1 - 7,4

5,4 - 7,1 - 8,0

7,5 - 8,0 - 9,0

7,5 - 8,0 - 10,6

1.060-1.320-1.580

1,0 - 1,4

DXC0104 HP

RAV-SM1104ATP-ERAV-SP1104AT(8)-E1

7,2 - 10,0 - 11,2

7,2 - 10,0 - 12,0

8,1 - 11,2 - 12,5

8,1 - 11,2 - 13,0

1.280-1.600-1.920

1,5 - 2,1

DXC0105 HP

RAV-SM1404ATP-ERAV-SP1404AT(8)-E1

10,1 - 12,5 - 13,2

10,1 - 12,5 - 14,0

11,3 - 14,0 - 16,0

11,3 - 14,0 - 16,5

1.680-2.100-2.520

1,7 - 2,7

DXC0106 HP

RAV-SM1603AT-ERAV-SP1604AT8-E1

12,6 - 14,0 - 16,0

14,1 - 16,0 - 19,0

1.850-2.800-3.740

1,7 - 3,2

DXC0108 HP

RAV-SM2244AT8-E

14,1 - 20,0 - 22,4

16,1 - 22,4 - 25,0

2.880-3.600-4.320

3,0 - 4,2

DXC01010 HP

RAV-SM2804AT8-E

20,1 - 23,0 - 27,0

22,5 - 27,0 - 31,5

3.360-4.200-5.040

3,0 - 5,4

Cooling capacity (min-rated*-max) DI

Cooling capacity (min-rated*-max) SDI

Heating capacity (min-rated*-max) DI

Heating capacity (min-rated*-max) SDI

AHU Air Volume (min-rated*-max)

Coil Internal Volume (min-max)

Cooling & Heating output figures are based on calculations and “general” test data. All figures are to be taken as approximations. The properties of the third party DX Coil will have an affect on the performance of the outdoor units.All capacity data shown is based on the following Rated Conditions:• Cooling (Rated): Indoor air temperature 27°C db / 19°C wb. Outdoor air temperature 35°C db• Heating (Rated): Indoor air temperature 20°C db. Outdoor air temperature 7°C db / 6°C wb.

Notes:Cooling Mode Coil “Air On” Temp: Minimum 15°CWB (18°CDB) / Maximum 24°CWB (32°CDB)Air temperatures flowing across the coil below this level, can in some circumstances, cause icing and freezing issues with the coil and eventually forcing the system to shut down and also be detrimental to the outdoor unit itself.

Heating Mode Coil “Air On” Temp: Minimum 15°CDB / Maximum 28°CDBIn the reserve cycle mode when the outdoor unit is producing hot gas, the coil in the AHU is effectively the condenser. Air temperatures flowing across the coil below this level, can cause over condensing of the refrigerant.This can result in liquid being returned to the compressor which will cause a mechanical failure of the outdoor unit.Low air temperatures will also cause the unit to use it’s defrost mode more often.

Fresh Air IntakeIf you wish to use Fresh Air whish in outside of these Coil “Air On” limits it has to either be pre-conditioned by other equipment, or mixed with return air (or a combination of both) so that it remainsinside these limits, in order to ensure reliable operation.

Automatic ModePlease be aware that frequent mode changes could occur when using Automatic mode.

TA sensorThe TA sensor should be positioned in the return air duct. In case, it’s not representative enough of the occupants area temperature, remote temperature sensor TCB -TC21LE2 should be used in the room.

Physical dataDX Controller unit RAV-

mm

kg

°C

°C

V-ph-Hz

DXC010

400x300x150

10

15°CWB÷24°CWB

15°CDB÷28°CDB

220/240-1-50

Dimensions (HxWxD)

Weight

Operating range - Cooling coil "Air on" temp

Operating range - Heating coil "Air on" temp

Power supply

51

RAV-DXC STANDARD DX KIT

Page 52: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

52

The DX kit enables connection and control of Toshiba LC outdoor units to a third-party air handling unit (with DX coil).

FLEXIBILITY► Compatible with the majority of air handling units with a DX coil fitted inside (capacity ranges from 4,6 to 27kW)► Air flow rate from 480 to 5.040m3/h

CONTROL► Capacity control and selection mode of the Toshiba outdoor unit directly from the AHU controller through a 0-10V signal

EASY TO INSTALL & MAINTAIN► Capacity set by DN code during installation► Extended 5 meters sensor leads pre-fitted to improve installation time and flexibility► Relay isolated inputs to prevent accidental wiring errors, damaging the PCB

Up to 4.200m3/h

MAX AIR FLOW

Compatible with both LC and VRF systems.(made possible via simple switch change on PCB).

2,5kW-27kW

CAPACITY

-27°C/+52°C

OPERATION

Page 53: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

53

RBC-DXC 0-10V DX KIT

Technical Limitations:• Cooling & Heating output figures are based on calculations and “general” test data. All figures are to be taken as approximations. The properties of the 3rd Party DX Coil will have an effect on the performance of the Outdoor units.• The DX Coil must be suitable for R410A.• The design should allow operation as both an Evaporator and a Condenser (Features: Multiple circuits / Liquid Capillary Distributor / Gas Header).• The standard Air volume flow rate is a guideline. The required capacity should determine DX-Interface size selection.• The counter flow principle must be observed for the DX coil design.• A Drain Pan must be fitted (even if only used in Heat mode) due to defrost cycles.• It is recommended to fit droplet eliminator plates in the discharge air stream if used in Cool mode.• 1:1 Connection: The DX Interface (0-10V) must be connected 1:1 with Toshiba outdoor units.• Only Heating and Cooling Modes are available on the RBC-DXC031 (No Automatic or Fan Only).

Capacity table

kW

kW

HP

LC / VRF DX Coil Controller UnitDX PMV valve unit

DXC031

-

RBC-

2,5

3,4

1,0

DXC031

-

3,6

4,0

1,5

DXC031

-

5,0

5,3 SM (5,6 SP)

2,0

DXC031

-

6,7 SM (7,1 SP)

7,7 SM (8,0 SP)

3,0

DXC031

-

10,0

11,2

4,0

DXC031

-

12,1 SM (12,5 SP)

12,8 SM (14,0 SP)

5,0

DXC031

-

14,0

16,0

6,0

DXC031

-

20,0

22,4

8,0

DXC031

-

23,0

27,0

10,0

Cooling capacity

Heating capacity

Power code

Physical Data

m3/h

m3/h

mm

kg

m

m

m

m

IP

°C / RH

°C

°C

LC / VRF DX CoilController Unit

DXC031RBC-

480

660

400x300x150

8

200

100

500

500

65

5-40 / 10-90

15°CWB÷24°CWB

5°CDB÷28°CDB

RAV-SM304ATP-E

522

690

400x300x150

8

200

100

500

500

65

5-40 / 10-90

15°CWB÷24°CWB

5°CDB÷28°CDB

RAV-SM404ATP-E

RAV-SP404TP-E

720

1.080

400x300x150

8

200

100

500

500

65

5-40 / 10-90

15°CWB÷24°CWB

5°CDB÷28°CDB

RAV-SM564ATP-E

RAV-SP564ATP-E

1.060

1.580

400x300x150

8

200

100

500

500

65

5-40 / 10-90

15°CWB÷24°CWB

5°CDB÷28°CDB

RAV-SM804ATP-E

RAV-SP804ATP-E

1.280

1.920

400x300x150

8

200

100

500

500

65

5-40 / 10-90

15°CWB÷24°CWB

5°CDB÷28°CDB

RAV-SM1104ATP-E

RAV-SP1104AT-E

RAV-SP1104AT8-E

1.680

2.520

400x300x150

8

200

100

500

500

65

5-40 / 10-90

15°CWB÷24°CWB

5°CDB÷28°CDB

RAV-SM1104ATP-E

RAV-SP1104AT-E

RAV-SP1104AT8-E

2.080

3.360

400x300x150

8

200

100

500

500

65

5-40 / 10-90

15°CWB÷24°CWB

5°CDB÷28°CDB

RAV-SM1603AT-E

RAV-SP1604AT8-E

2.880

4.320

400x300x150

8

200

100

500

500

65

5-40 / 10-90

15°CWB÷24°CWB

5°CDB÷28°CDB

RAV-SM2224AT8-E

3.360

5.040

400x300x150

8

200

100

500

500

65

5-40 / 10-90

15°CWB÷24°CWB

5°CDB÷28°CDB

RAV-SM2804AT8-E

DXC031 DXC031 DXC031 DXC031 DXC031 DXC031 DXC031 DXC031

Minimum Air Flow rate

Maximum Air Flow rate

Dimensions (HxWxD)

Weight

Cable Max Length (Analogue Input) (Screened cable: 0.5 ~ 1.0 mm2)

Cable Max Length (Digital Input) (Non screened cable: 1.5 ~ 2.5 mm2)

Cable Max Length (Digital Output) (Non screened cable: 1.5 ~ 2.5 mm2)

Cable Max Length (TCC Link) (Non screened cable: 0.5 mm2)

Standard Rating

Operating temperature/humidity

Operating range - Cooling coil "Air on" temp

Operating range - Heating coil "Air on" temp

Outdoor Unit

Power supply Supplied from Outdoor unit

Page 54: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Air curtains are designed to be positioned above an entrance, providing a thermal curtain, which separates the outdoor and indoor environments. This historically has been produced by electrical heaters, however it is now possible to use a Toshiba heat pump system, with the added benefit of improved energy savings.

The air is accelerated and forced through a narrow discharge along the length of the air curtain creating a laminar air flow.

ENERGY SAVINGS► Stop drafts and reduces infiltration of outdoor air into the heated or air-conditioned area► EC motors compliant with ERP lot 11

COMFORT► By preventing the conditioned air to leave the building, or be affected by incoming air from the outside, the comfort levels inside the building are maintained, making it a more pleasant area for staff members and customers alike

FUNCTIONALITY► Provides a pleasant entrance to customers, whilst ensuring undesirable smells, contaminants and small insects are kept outside of the conditioned space

ADAPTABILITY► Suitable for installation in the ceiling space above the door, only the inlet grille and discharge outlet will be visible► Available in door widths from 1m to 2,5m

8kW-16kW

CAPACITY

-20°C/+46°C

OPERATION

54

Page 55: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

Air Curtain Free-Hanging unit (CH)

3,0

3,0

4,0

4,0

5,0

5,0

6,0

6,0

Model Code Heating Capacity kW Outdoor Sizing hp

8,0

8,0

11,2

11,2

14,0

14,0

16,0

16,0

Air flow rate m3/h

1.600

2.210

2.400

2.950

3.200

4.420

4.000

5.160

Power Input Fan only kW

0,35

0,53

0,53

0,70

0,70

1,05

0,88

1,23

Door Width mm

1.000

1.000

1.500

1.500

2.000

2.000

2.500

2.500

Max Door Height m

3,0

3,2

3,0

3,2

3,0

3,2

3,0

3,2

Unit Weight kg

48

51

77

80

101

107

132

138

Sound Pressure dBA

54

55

55

56

56

57

57

58

RAV-CT101CH-M

RAV-CT101CH-L

RAV-CT151CH-M

RAV-CT151CH-L

RAV-CT201CH-M

RAV-CT201CH-L

RAV-CT251CH-M

RAV-CT251CH-L

Air Curtain Cassette unit (UH)

3,0

3,0

4,0

4,0

5,0

5,0

6,0

6,0

Model Code Heating Capacity kW Outdoor Sizing hp

8,0

8,0

11,2

11,2

14,0

14,0

16,0

16,0

Air flow rate m3/h

1.600

2.210

2.400

2.950

3.200

4.420

4.000

5.160

Power Input Fan only kW

0,35

0,53

0,53

0,70

0,70

1,05

0,88

1,23

Door Width mm

1.000

1.000

1.500

1.500

2.000

2.000

2.500

2.500

Max Door Height m

3,0

3,2

3,0

3,2

3,0

3,2

3,0

3,2

Unit Weight kg

40

43

95

98

99

105

120

126

Sound Pressure dBA

54

55

55

56

56

57

57

58

RAV-CT101UH-M

RAV-CT101UH-L

RAV-CT151UH-M

RAV-CT151UH-L

RAV-CT201UH-M

RAV-CT201UH-L

RAV-CT251UH-M

RAV-CT251UH-L

Air Curtain Built-in unit (BH)

3,0

3,0

4,0

4,0

5,0

5,0

6,0

6,0

Model Code Heating Capacity kW Outdoor Sizing hp

8,0

8,0

11,2

11,2

14,0

14,0

16,0

16,0

Air flow rate m3/h

1.600

2.210

2.400

2.950

3.200

4.420

4.000

5.160

Power Input Fan only kW

0,35

0,53

0,53

0,70

0,70

1,05

0,88

1,23

Door Width mm

1.000

1.000

1.500

1.500

2.000

2.000

2.500

2.500

Max Door Height m

3,0

3,2

3,0

3,2

3,0

3,2

3,0

3,2

Unit Weight kg

71

74

105

108

129

135

170

176

Sound Pressure dBA

54

55

55

56

56

57

57

58

RAV-CT101BH-M

RAV-CT101BH-L

RAV-CT151BH-M

RAV-CT151BH-L

RAV-CT201BH-M

RAV-CT201BH-L

RAV-CT251BH-M

RAV-CT251BH-L

Outdoor units combination Model Code (CH / UH / BH) Door Width (mm)

1.000

1.000

1.500

1.500

2.000

2.000

2.500

2.500

Max Door Height (m)

3,2

3,0

3,2

3,0

3,2

3,0

3,2

3,0

DI3 - Single phase

-

-

-

-

-

-

RAV-SM1603AT-E1

RAV-SM1603AT-E1

SDI- Single phase

RAV-SP804AT-E

RAV-SP804AT-E

RAV-SP1104AT-E

RAV-SP1104AT-E

RAV-SP1404AT-E

RAV-SP1404AT-E

RAV-SP1604AT-E

RAV-SP1604AT-E

DI4- Single phase

RAV-SM804ATP-E

RAV-SM804ATP-E

RAV-SM1104ATP-E

RAV-SM1104ATP-E

RAV-SM1404ATP-E

RAV-SM1404ATP-E

-

-

SDI - Three phases

-

-

RAV-SP1104AT8-E1

RAV-SP1104AT8-E1

RAV-SP1404AT8-E1

RAV-SP1404AT8-E1

RAV-SP1604AT8-E1

RAV-SP1604AT8-E1

RAV-CT101**-L

RAV-CT101**-M

RAV-CT151**-L

RAV-CT151**-M

RAV-CT201**-L

RAV-CT201**-M

RAV-CT251**-L

RAV-CT251**-M

55

RAV-CT AIR CURTAINS

Page 56: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

56

NOTES

Page 57: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment
Page 58: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment
Page 59: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

The manufacturer reserves the right to change the product specifications, data and images without previous notice. ΑΗΙ CARRIER S.E. EUROPE SINGLE MEMBER S.A. is not responsible for printing mistakes.

2020-2021 AHI CARRIER S.E. EUROPE SINGLE MEMBER S.A., all rights reserved.

Page 60: YOUR BUSINESS, YOUR COMFORT · 2020-05-19 · business, your comfort air conditioners light commercial solutions catalogue 2020-2021. index welcome to a world of innovation our commitment

AHI CARRIER SOUTH EASTERN EUROPE AIR CONDITIONING SINGLE MEMBER S.A.

HEADQUARTERS18, Kifissou Ave. 104 42 - Athens, Tel.: +30 210 6796300, Fax: +30 210 6796390, www.toshiba-aircon.grTHESSALONIKI BRANCH5, Ag. Georgiou Str., Cosmos Offices, 570 01 - Patriarhiko Pileas, Thessaloniki, Tel.: +30 231 3080430, Fax: +30 231 3080435AHI CARRIER HVAC BULGARIA EOODTrade Center Europe, Building 6, floor 3, office 6, 7 Iskarsko Shose Blvd. Sofia, 1520 - BULGARIA, Tel.: +35 929483960 Fax: +35 929483990, www.toshiba-aircon.bgAHI CARRIER ROMANIA SRL270d Turnu Magurele Str., Sector 4, Cavar center, Bucharest - ROMANIA, Tel.: +40 214 050751, Fax: + 40 214 050753, www.toshiba-hvac.ro