your business, your comfort · 2020-05-19 · business, your comfort air conditioners light...
TRANSCRIPT
YOURBUSINESS,YOURCOMFORT
AIR CONDITIONERSLIGHT COMMERCIAL SOLUTIONS CATALOGUE 2020-2021
INDEXWELCOME TO A WORLD OF INNOVATION
OUR COMMITMENT TO THE FUTURE
INVERTER SYSTEMS
LIGHT COMMERCIAL SOLUTIONS
GP_AT SUPER DIGITAL INVERTER
GM_AT8 BIG DIGITAL INVERTER
GM_ATP(8) DIGITAL INVERTER
GM_UT 4-WAY SMART CASSETTE
RM_UT 4-WAY CASSETTE
RM_MUT COMPACT 4-WAY CASSETTE
RM_BTP STANDARD DUCT
RM_SDT SLIM DUCT
RM_DTP HIGH STATIC DUCT
RM_FT FLOOR STANDING
RM_CTP CEILING
RM_KRTP HIGH-WALL
SDI-DI TWIN
RAV-DXC STANDARD DX KIT
RBC-DXC 0-10V DX KIT
RAV-CT AIR CURTAINS
04
10
14
18
20
22
24
26
28
30
32
34
36
38
40
42
44
50
52
54
Preliminary data
04
It all began in Japan in 1875. Two Japanese innovators, Hisashige Tanaka, a mechanical engineering genius, and Ichisuke Fujioka, an expert of electricity, decided to join their forces in order to create a world of progress focusing on humanity and the improvement of daily life: Toshiba.
05
Today, 140 years later, all of us in Toshiba are still inspired by their example. We continue to work, research and break new ground to offer you highly evolved and up to date solutions on air conditioning and heating, always caring for the environment. We stand by our founders’ initial vision by providing a better quality of life for everyone through elegant and secure products, and advanced technological machinery.
WELCOME TO A WORLD OF INNOVATION
Our products, trusted by millions of people all over the world, are based upon the unique Japanese Research & Development. Their characteristic design makes them unique and they stand out globally, as they are known to create a beautiful interior environment, no matter how harsh the conditions outside.
We are certain that even now, that Toshiba is undoubtedly a world leader in the global air conditioning market, we remain loyal to our founders’ initial vision: to create a better quality of life for everyone, no matter what their space of living is, no matter which country they inhabit, so as to make them feel comfortable and happy in a room of ideal conditions, in short – in the perfect climate!
06
For every spaceHome, store, office or hotel; each building has its own unique demands and special features. Toshiba creates a perfect environment of comfort and encourages productivity. Whatever you use your space for, Toshiba is here to help you create the best possible conditions of comfort.
For every demandAlways driven by our standards for the creation of innovative high-end technological products, we offer you reliable and secure solutions that cover every possible demand. Now your world is getting simpler, clearer, and more effective thanks to the technical building usage systems of Toshiba. Whatever your situation, our groundbreaking solutions are here for you.
07
For every needIn a world of infinite choices and unmeasurable possibilities, Toshiba satisfies every need. The solutions offered for heating and air conditioning match your needs perfectly, down to the smallest detail and always with the best outcome.
INNOVATIVE SOLUTIONS FOR A CONFIDENT LIVING
08
Everyday technology and innovation We stand out for the high standard Japanese technology of our products, for our unparalleled innovation and our subtle design. Our aim is to offer through our products a most safe, comfortable and productive life to our trusting clients.
We combine our spirit for innovation with our passion for a better future. Protecting the environment is our guiding commitment, since it is our common heritage throughout the planet. We cultivate close relations based upon mutual trust and respect. What drives us is our strong bonds with our clients, our business associates and communities all around the world.
Eurovent programme Eurovent is an independent European organization with the strictest requirements globally, which verifies that the technical features and performance of air conditioning products follow all European guidelines.
All Toshiba residential products are certified by Eurovent programme. This is a guarantee for customers and users that our products will operate in accordance with the design specifications and that their published technical characteristics, performance and Energy Ratings are true.
COMMITED TO A BETTER WORLD FOR A FACT
09
To improve its environmental responsibility, Toshiba Air Conditioning offers products that meet the following European standards:
This directive determines the requirements and performance measurements of air conditioners and heat pumps.
This directive determines the methodology for the calculation of seasonal performance for space heating and cooling of air conditioners and heat pumps, with electrical driven compressors.
This directive involves heat pumps with electrical driven compressors and determines the requirements for marking domestic hot water units.
European standards
EN 14511 EN 14825 EN 16147
The Regulation aims to progressively abolish the use of hydrocarbons in future heating and cooling systems.
517/2014 F-gas
The planet is our home
It is imperative for us to play an active role in protecting our planet; it is something we defend daily. At Toshiba Air Conditioning, we believe we can make a difference. We are committed to advancing research and developing super-energy-efficient technologies. This commitment is in line with the European Union's climate and energy objectives for 2030.
Toshiba Air Conditioning also assesses the impact of its business activities, products and services on the environment and sets targets aiming to reduce environmental impact and prevent pollution.
10
27%SHARE OF
RENEWABLE ENERGY
Sour
ce: T
OSH
IBA
CORP
ORA
TIO
N E
nviro
nmen
tal R
epor
t 201
6
Concurrently Toshiba Group is also conducting group-wide environmental activities based on the recognition of the importance of maintaining and expanding environments for conserving biodiversity.
59%REDUCTION
45%REDUCTION
created at production &business sites worldwide
from 2012 to 2015
62BIOTOPES
inhabit Toshiba Group’sproduction & business
sites worldwide
100RARE SPECIES
89%REDUCTION
27%IMPROVEMENT
IN ENERGY EFFICIENCY
-40%GREENHOUSE
GAS EMISSIONS
in total volume of CO2emissions from
1990 to 2015
in total volume of wastegenerated from
2000 to 2015
in total volume ofchemical emissionsfrom 2000 to 2015
11
OUR COMMITMENT TO THE FUTURE,STARTING FROM TODAY
Environmental action plan
In order to realize an ideal state of the Earth in 2050, Toshiba Group formulates Environmental Action Plan for medium-term goals and manages specific environmental activities and their targets. Under the ongoing Sixth Environmental Action Plan for the period from FY2017 to FY2020, we set goals for 15 items in two areas: or namely activities to reduce environmental impacts in the lifecycles of products and services (Business), and basic activities to support such activities (Management).
Developing Strategies in Two Areas: Business and ManagementEnvironmental Vision 2050
Helping resolve global environmental issues
Business
ManagementPromoting basic activities that support business initiatives
Creating a system that supports strict compliance and enhancing basic activities to meet public expectations
Pursuing high-efficiency manufacturing thatsimultaneously reduces environmental impacts and costs
Promoting initiatives to reduce environmental impacts in product/service lifecyclesReducing environmental impacts in manufacturing
Development of energy technologies and energy-savingproducts and services to help realize a low-carbon society
Improving environmental performance of products and services
Reduction of GHGemissions
Reduction of wasteand water received
Reduction ofchemicals discharged
Ensuring of environmental risk compliance Environmental communication Conservation of biodiversity
Further reductionof CO2 emissions
More resourcesconserved or
recycled
Reduction of specifiedchemical substances
contained in products
Products designed to perform, engineered to perfection
Digital DC Twin Rotary Inverter Compressor
Ensures a steady rotation speed and reduces any unwanted vibration. The results are unique:
Increased efficiency
The compressor has a particularly high efficiency
at low rotational speeds and during long-running
steady conditions.
Energy saving
Thanks to the anti-asymmetric
twin-cylinder rotation, the compressor offers great energy savings and very
powerful and reliable operation.
High reliability& low noise level
Stable performance with minimal friction loss. The ideal
solution for noise-sensitive applications. The noise of the outdoor unit during operation is almost negligible, and at the
same time it ensures double lifespan for the compressor.
12
13
Environmental friendlyToshiba units perfectly keep the balance between environment safety and comfort, along with the increased energy efficiency for greater savings.
Reducing the CO2 emissionsR32 low GWP, combined with Toshiba’s units 30% reduction of refrigerant charge, allows to reduce the total equivalent CO2 by 80% of the system, in comparison with equivalent capacities of Toshiba R410A legacy units.
ONLY EXCELLENCE CAN BE NAMED TOSHIBA
Easy to install► Working pressures for R410A and R32 refrigerant are similar► R32 refrigerant can be easily charged in both liquid or gas state► Safety commissioning instructions are similar to those for R410A► R32 and R410A equipments are the same, except the refrigerant recovery pump and the reclaim cylinder► Toshiba flare joints are ISO14903 certified, in anticipation of the new IEC60335-2-40 edition 5 regulation, which will allow flare connection inside the room.
GWP (1)
ODP (2) X.XXR23(HFC) R12(CFC) R11(CFC) R22 (HCFC) R410A (HFC) R32 (HFC) CO 2
1.0 X.XX 0.05 0 X.XX
14.800 10.900
1987 - The Montreal Protocol
4.750 1.810 2.090
Around1/3
1
675
1997 - The Kyoto Protocol
LIFE-CYCLE CLIMATE PERFORMANCE
R410A
R32SUZUMI+ R32Vs SUZUMI+ R410A
100%(0.81kg)
2088 1670
675344
(0.51kg)
63%x = -80%
GWP Unit refrigerant charge (% / kg)
CO2 equivalent (kg) GWP x Refrigerant charge
(1) Global Warming Potential(2) Ozon Depletion Potential
14
High performance and minimised consumptionThe Toshiba Digital and Super Digital Inverter systems are powerful and extremely efficient. They provide air conditioning with great energy savings.The Super Digital Inverter provides the best performance in the industry on part load conditions, both in cooling and heating mode. In most applications, these systems can reduce the Seasonal Energy Consumption.The variable capacity management of the compressor allows the Digital and Super Digital Inverter to maintain the control of the room temperature and to ensure minimum energy wastage.
Unparalleled flexibilityFor the professionals seeking high perfor-mance, compact units and optimum comfort, Toshiba has the ideal product.Toshiba never ceases improving the inverter control system: the vector control for its DC hybrid inverter enhances system efficiency and reduces noise levels. High-tech elements include improved coils, high precision components and higher refrigerant compression, thanks to rede-signed compression channels.Super Digital and Digital Inverter systems are able to satisfy applications that require cooling up to +52°C (+46°C for DI) and heating down to -27°C (-20°C for DI).DC twin-rotary compressor delivers stable perfor-mance with extremely low rotor friction, making it ideal for noise-sensitive applications, as well as for efficient operations in partial load conditions.
Inverter becomes DigitalThe Digital Inverter control module technology ensures optimised reproduction of the sine wave supply at the desired frequency, in order to reduce inefficient harmonics that inverters normally emit.With this innovative control method, the Toshiba Digital Inverter brings state-of-the-art inverter technology to the commercial sector, offering great advantages in terms of capacity, energy savings and optimised comfort.
15
Maximum efficiencyVery efficient energy consumption, keeps down operating costs: SEER of 9,40 and SCOP of 5,51 achieved by Toshiba’s unrivalled Super Digital Inverter technologies and newly developed components.
Piping flexibilitySuper Digital Inverter, leader in the industry, efficiently supports the height differences, of up to 30 meters, on a single system. Enough height to cover an 8-storey building! Consequently, the outdoor unit can be installed out of sight, increasing installation flexibility (only 4 & 5HP).
DC Twin rotary compressor and vector-controlled InverterThe advantages of inverter technology are further optimised when combined with Toshiba twin-rotary compressors, giving exceptional speed control in the capacity range from 20 to 100% capacity: a unique Toshiba benefit!
Operating temperature rangeHeater operation starts from an outdoor temperature of -27°C, creating a comfortable space even during cold winters, while cooling operation is possible up to 52°C outdoor temperature. This enables wider applications and use of the system in colder regions.
RAV Super Digital InverterToshiba Super Digital Inverter series perfectly combine economy and ecology in a compact body. They feature state-of-the-art technology, flexible control, and easy installation, for great comfort and convenience to any business environment. SDI outdoor units are compatible with a complete range of indoor units: Cassette, Ducted, Ceiling and High-Wall units.
INVERTER SYSTEMS
8F7F6F5F4F3F2F1F
Sing
le s
yste
m Height
between
indoor units
30m
cooling mode
Temperatureoperating
range
heating mode
16
RAV Digital InverterToshiba continues to improve its range of split systems dedicated to commercial applications. Digital Inverter (DI) has been totally redesigned, becoming more compact and more effective. The performance of these systems provide significant energy savings for a rapid return on investment. Comfort, ease of installation and simplicity are the strengths of Toshiba systems.
Small and light chassisLess than 900mm up to 5HP, the Digital Inverter is extremely compact and can be installed in very small spaces. In addition, chassis under 5HP are less than 70kg.
Wide capacity range▪ 9 sizes from 1HP to 10HP with 1Ph or 3Ph electrical ▪ Connection to cover every type of projects, from the 15m² room to the 200m² shop, in new construction and refurbishment as well
Smart InverterHybrid inverter control combines two intelligent control mechanisms to reach the set point temperature as quickly as possible with maximum efficiency:▪ Τhe PAM mode, quickly achieves high capacity and desired comfort.▪ Τhe PWM mode minimizes power input to maximize efficiency.
The result: high efficiency level.
550mm
890mm
1HP to 3HP 4HP & 5HP
1HP 1.5HP 2HP 3HP 4HP 5HP 6HP 8HP 10HP
1Ph
3Ph
✔
✔
✔ ✔ ✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Operating temperature rangeOperation is possible starting from an outdoor temperature of -15°C (-27°C for Big DI), while cooling operation is possible at -15°C and up to 46°C (52°C for Big DI) outdoor temperature. This enables wider applications and use of the system everywhere.
Temperatureoperationrange (in °C)
cooling mode
heating mode
17
INVERTER SYSTEMS
18
Professional solutionsfor professional needsToshiba Digital and Super Digital Inverter systems are extremely compact units with exceptional operating savings. State-of-the-art technologies, flexible controls and improved installation go along with comfort and convenience, for all kind of business installations.
Ceiling, cassette, ducted, suspended and high-wall: a complete range of indoor units ready to suit all commercial applications. All Toshiba systems, expanded with maximum cooling capacities of up to 27kW, benefit additional commercial applications with larger volumes.
LIGHT COMMERCIAL SOLUTIONS
5,51
SCOP MAX
The Toshiba Super Digital Inverter series is leading energy efficiency, operating range and piping length, offering the best solution for the majority of commercial projects and large residential applications.
Power consumption analysis embedded when SDI series is combined with theRBC-AMS55E-ES/-EN.
TOP CLASS EFFICIENCY► High efficiency SCOP of up to 5,51, thanks to Toshiba inverter technology
WIDE ADAPTABILITY► Operating temperature limits from -27°C (Heating) to +52°C (Cooling) allow the system to operate across a wide temperature range► Quiet operation
FLEXIBLE► Can be utilised for single, twin or triple indoor applications
EASY MAINTENANCE► Removable corner panels for easy access► Self-diagnosis function
5kW-14kW
CAPACITY
-27°C/+52°C
OPERATION
POWER CONSUMPTION(WEEK)
20
Physical data outdoor - Single phase
Air Flow
Sound pressure level
Sound power level
Operating range
Sound pressure level
Sound power level
Operating range
Dimensions (HxWxD)
Weight
Compressor type
Flare connections
Gas
Liquid
Minimum pipe length
Maximum pipe length
Maximum height difference
Chargeless pipe length
Refrigerant
Power supply
C = cooling mode H = heating mode
m3/h - l/s
dB(A)
dB(A)
°C
dB(A)
dB(A)
°C
mm
kg
in
in
m
m
m
m
Type/kg
V-ph-Hz
C
C
C
H
H
H
Outdoor unitRAV-GP561ATP-E
2 HP
2.250-625
46
63
-15 / 52
48
65
-27 / 15
630x799x299
45
DC Twin Rotary
1/2
1/4
3
50
30
20
R32 / 1,35
220/240-1-50
RAV-GP801AT-E3 HP
3.180-883
46
63
-15 / 52
48
65
-27 / 15
1.050x1.010x370
74
DC Twin Rotary
5/8
3/8
3
50
30
30
R32 / 1,9
220/240-1-50
RAV-GP1101AT-E4 HP
6.960-1.933
49
66
-15 / 52
50
67
-27 / 15
1.550x1.010x370
104
DC Twin Rotary
5/8
3/8
3
75
30
30
R32 / 3,1
220/240-1-50
RAV-GP1401AT-E5 HP
6.960-1.933
50
67
-15 / 52
51
68
-27 / 15
1.550x1.010x370
104
DC Twin Rotary
5/8
3/8
3
75
30
30
R32 / 3,1
220/240-1-50
Physical data outdoor - Three phase
Outdoor unit
Air Flow
Sound pressure level
Sound power level
Operating range
Sound pressure level
Sound power level
Operating range
Dimensions (HxWxD)
Weight
Compressor type
Flare connections
Gas
Liquid
Minimum pipe length
Maximum pipe length
Maximum height difference
Chargeless pipe length
Power supply
C = cooling mode H = heating mode
m3/h - l/s
dB(A)
dB(A)
°C
dB(A)
dB(A)
°C
mm
kg
in
in
m
m
m
m
V-ph-Hz
C
C
C
H
H
H
RAV-GP1101AT8-E4 HP
6.060 - 1.683
49
66
-15 / 46
50
67
-20 / 15
1340x900x320
95
DC Twin Rotary
5/8
3/8
3
75
30
30
380/415-3N-50
RAV-GP1401AT8-E5 HP
6.180 - 1.717
51
68
-15 / 46
52
69
-20 / 15
1340x900x320
95
DC Twin Rotary
5/8
3/8
3
75
30
30
380/415-3N-50
RAV-GP1601AT8-E6 HP
6.180 - 1.717
51
68
-15 / 46
53
70
-20 / 15
1340x900x320
95
DC Twin Rotary
5/8
3/8
3
75
30
30
380/415-3N-50
21
GP_AT SUPER DIGITAL INVERTER
3,51
SCOP MAX
Big DI has been designed to provide a high capacity output from a very small foot print.
The installation can reach up to 60m total piping length and 30m in elevation without additional safety measures.
HIGH EFFICIENCY & ENERGY SAVINGS► Best EER and COP in its class incorporating Toshiba’s exclusive Inverter twin-rotary compressor made in Japan► Compliant with ERP directive lot 21► Top class part load efficiency
WIDE ADAPTABILITY► Allows connection of four indoor units (same type and capacity) to one outdoor unit► Compatible with a wide choice of indoor units: 4-way cassette, 4-way compact cassette, slim duct, standard duct, high-wall and ceiling
SAFETY & RELIABILITY► Built-in leak detection system► Compliant with the child finger entrapment regulation
19kW-27kW
CAPACITY
-27°C/+46°C
OPERATION
22
Physical data outdoor - Three phase
Outdoor unit
C = cooling mode H = heating mode
m3/h - l/s
dB(A)
dB(A)
°C
dB(A)
dB(A)
°C
mm
kg
in
in
m
m
m
m
V-ph-Hz
C
C
C
H
H
H
RAV-GM2241AT8-E8 HP
9.150 - 2.541
58
76
-15 / 46
60
76
-27 / 15
1.550x1.010x370
142
DC Twin Rotary
1 1/8
1/2
5
60
30
30
380/415-3N-50
RAV-GM2801AT8-E10 HP
10.890 - 3.025
61
78
-15 / 46
63
80
-27 / 15
1.550x1.010x370
142
DC Twin Rotary
1 1/8
1/2
5
60
30
30
380/415-3N-50
Air Flow
Sound pressure level
Sound power level
Operating range
Sound pressure level
Sound power level
Operating range
Dimensions (HxWxD)
Weight
Compressor type
Flare connections
Gas
Liquid
Minimum pipe length
Maximum pipe length
Maximum height difference
Chargeless pipe length
Power supply
23
GM_AT8 BIG DIGITAL INVERTER
4,51
SCOP MAX
Toshiba Digital Inverter brings state-of-the-art inverter technology to the commercial sector, offering considerable advantages in terms of capacity, energy savings, optimised control, lower refrigerant charge. In addition, it has the smallest physical dimensions and lightest range of outdoor units in the industry.
Toshiba state-of-the-art compressor features a powerful magnetic rotor with great surface area to increase efficiency and reduce the operation noise.
☻Efficiency☻Reliability☻100% Toshiba
LIGHT & COMPACT► Up to 14kW in only 890mm height and 69kg
WIDE ADAPTABILITY► Compatible with a wide choice of indoor units: 4 way cassette, 4-way compact cassette, slim duct, standard duct, high wall and ceiling► Night operation mode to minimize the outdoor unit sound as low as 33dB(A)
EFFICIENCY & ENERGY SAVINGS► The Vector Intelligent Drive Unit (IPDU) technology ensures power limitation by 1% step between 50% and 100% load for optimal capacity control
EASY MAINTENANCE► Removable corner panels for easy access► Auto diagnostic function
2kW-16kW
CAPACITY
-15°C/+46°C
OPERATION
24
Physical data outdoor - Single phase
Physical data outdoor - Three phase
m3/h - l/s
dB(A)
dB(A)
°C
dB(A)
dB(A)
°C
mm
kg
in
in
m
m
m
m
V-ph-Hz
C
C
C
H
H
H
Outdoor unitRAV-GM301ATP-E
1 HP
1.800 - 500
46
61
-15 / 46
47
62
-15 / 15
550x780x290
33
DC Rotary
3/8
1/4
2
20
10
15
220/240-1-50,
220-1-60
RAV-GM401ATP-E1.5 HP
2.200 - 611
49
64
-15 / 46
50
65
-15 / 15
550x780x290
39
DC Twin Rotary
1/2
1/4
2
20
10
15
220/240-1-50,
220-1-60
RAV-GM561ATP-E2 HP
2.400 - 667
46
63
-15 / 46
48
65
-15 / 15
550x780x290
40
DC Twin Rotary
1/2
1/4
5
30
30
20
220/240-1-50
220-1-60
RAV-GM801ATP-E3 HP
2.700 - 750
48
65
-15 / 46
52
69
-15 / 15
550x780x290
44
DC Twin Rotary
5/8
3/8
5
30
30
20
220/240-1-50
220-1-60a
RAV-GM901ATP-E3.5 HP
2.900 - 806
51
68
-15 / 46
55
72
-15 / 15
630x800x300
47
DC Twin Rotary
5/8
3/8
5
50
30
30
220/240-1-50
220-1-60
RAV-GM1101ATP-E4 HP
4.080 - 1.133
54
70
-15 / 46
57
74
-15 / 15
890x900x320
68
DC Twin Rotary
5/8
3/8
5
50
30
30
220/240-1-50
220-1-60
RAV-GM1601ATP-E6 HP
6.900 - 1.917
53
70
-15 / 46
55
72
-15 / 15
1.340x900x320
95
DC Twin Rotary
5/8
3/8
5
50
30
30
220/240-1-50
220-1-60
RAV-GM1401ATP-E5 HP
4.200 - 1.167
55
70
-15 / 46
57
74
-15 / 15
890x900x320
68
DC Twin Rotary
5/8
3/8
5
50
30
30
220/240-1-50
220-1-60
Air Flow
Sound pressure level
Sound power level
Operating range
Sound pressure level
Sound power level
Operating range
Dimensions (HxWxD)
Weight
Compressor type
Flare connections
Gas
Liquid
Minimum pipe length
Maximum pipe length
Maximum height difference
Chargeless pipe length
Power supply
C = cooling modeH = heating mode
C = cooling mode H = heating mode
m3/h - l/s
dB(A)
dB(A)
°C
dB(A)
dB(A)
°C
mm
kg
in
in
m
m
m
m
V-ph-Hz
C
C
C
H
H
H
4.080 - 1.133
54
70
-15 / 46
57
74
-15 / 15
890x900x320
69
DC Twin Rotary
5/8
3/8
5
50
30
30
380/415-3-50,
380-3-60
4.200 - 1.167
55
70
-15 / 46
57
74
-15 / 15
890x900x320
69
DC Twin Rotary
5/8
3/8
5
50
30
30
380/415-3-50,
380-3-60
Air Flow
Sound pressure level
Sound power level
Operating range
Sound pressure level
Sound power level
Operating range
Dimensions (HxWxD)
Weight
Compressor type
Flare connections
Gas
Liquid
Minimum pipe length
Maximum pipe length
Maximum height difference
Chargeless pipe length
Power supply
RAV-GM1101AT8P-E4 HP
RAV-GM1401AT8P-E5 HP
6.900 - 1.917
53
70
-15 / 46
55
72
-15 / 15
1.340x900x320
94
DC Twin Rotary
5/8
3/8
5
50
30
30
380/415-3-50,
380-3-60
RAV-GM1601AT8P-E6 HPOutdoor unit
25
GM_ATP(8) DIGITAL INVERTER
5,51
SCOP MAX
Dedicated for commercial application, the Toshiba smart cassette is the perfect mix between comfort, elegance and efficiency.
Louver position automatically adjusts to prevent cold draught being felt by users.
EFFICIENCY► Top class SEER and SCOP, thanks to long slit heat exchanger with magic coil treatment, high efficiency fan motor and large opening air conditioning ventilation► Energy saving with the occupancy sensor which will automatically switch off the unit if nobody is in the room
COMFORT► Unique flap design for optimal air distribution► Individual setting of louver position: 3 different swing modes: standard, diagonally, opposite or turn around► 5 fan steps to precisely control the air flow
DESIGN► Simple & elegant design fits various rooms
5kW-14kW
CAPACITY
-27°C/+52°C
OPERATION
26
Performance data with Super Digital Inverter
C = cooling mode H = heating mode
Physical data indoor
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Cassette)
RAV-GP561ATP-ERAV-GM561UT-E
5,0
1,2-5,6
0,19-1,20-2,03
4,17
8,07
A++
217
5,6
0,9-7,4
0,16-1,29-2,76
4,34
5,01
A++
1.061
RAV-GP801AT-ERAV-GM801UT-E
7,1
1,9 - 8,0
0,26-1,37-2,94
5,18
9,40
A+++
264
8,0
1,3 - 11,3
0,20-1,45-3,15
5,52
5,51
A+++
1.294
RAV-GP1101AT-ERAV-GM1101UT-E
10,0
3,1 - 12,0
0,56-1,90-2,80
5,26
8,80
A+++
398
11,2
2,6 - 13,0
0,41-2,18-2,98
5,14
5,00
A++
2.573
RAV-GP1401AT-ERAV-GM1401UT-E
12,5
3,1 - 14,0
0,56-2,91-3,40
4,30
8,30
TBD
903
14,0
2,6 - 16,5
0,41-3,04-4,18
4,61
4,97
TBD
2.702
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
m3/h - l/s
dB(A)
dB(A)
mm
kg
mm
kg
Indoor unit RAV-GM561UT-E
1.050/750 - 291/208
32-29-26
48-45-43
256×840×840
20
30×950×950
5
RAV-GM801UT-E
1.920/810 - 533/225
42-35-27
56-49-43
319×840×840
25
30×950×950
5
RAV-GM1101UT-E
2.250/1050 - 625/291
48-40-31
61-54-46
319×840×840
25
30×950×950
5
RAV-GM1401UT-E
2.250/1170 - 625/325
48-41-33
61-55-48
319×840×840
25
30×950×950
5
Air Flow (H/L)
Sound pressure level (H-M-L)
Sound power level (H-M-L)
Dimensions (HxWxD)
Weight
Panel dimensions (HxWxD)
Panel weight
C = cooling mode H = heating mode
27
GM_UT 4-WAY SMART CASSETTE
5,22
SCOP MAX
4-way cassette is designed to provide uniform air distribution and total comfort. It is the ideal solution for small commercial application.
Optimal air diffusion up to 4,6m ceiling height!
COMFORT► Two louvers shape option: straight flow louver and wide flow louver; optimum air distribution► Individual setting of louver position: 3 different swing mode: standard, diagonally, opposite, turn around► Wide air flow in all directions
RELIABILITY► Self-cleaning function and Ag-ion tip for anti-mould in drain cap► Built-in high-lift drain pump
EASY INSTALLATION► Compact chassis with only 256mm height (sizes 5 and 8)► Light-weight unit, for easy and quick installation
5kW-16kW
CAPACITY
-27°C/+52°C
OPERATION
4,6 m
Max height
28
29
RM_UT 4-WAY CASSETTE
Performance data with Super Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Cassette)
RAV-GP561ATP-ERAV-RM561UTP-E
5,0
1,2-5,6
0,19 -1,22 -1,97
4,10
7,61
A++
230
5,6
0,9-8,1
0,16 -1,30 - 2,76
4,31
4,96
A++
1.071
RAV-GP801AT-ERAV-RM801UTP-E
7,1
1,9 - 8,0
0,26 - 1,58 - 3,15
4,49
8,80
A+++
282
8,0
1,3 - 11,3
0,20 - 1,77 - 3,47
4,52
5,22
A+++
1.367
RAV-GP1101AT-ERAV-RM1101UTP-E
10,0
3,1 - 12,0
0,53 - 2,13 - 3,05
4,69
8,65
A+++
405
11,2
2,6 - 13,0
0,40 - 2,34- 3,08
4,79
4,73
A++
2.719
RAV-GP1401AT-ERAV-RM1401UTP-E
12,5
3,1 - 14,0
0,53 - 3,16 - 3,55
3,96
8,15
TBD
920
14,0
2,6 - 16,5
0,40 - 3,21 - 4,38
4,36
4,72
TBD
2.844
RAV-GP1101AT8-ERAV-RM1101UTP-E
10,0
2,6 - 12,0
0,66 -2,32- 3,60
4,31
7,1
A++
492
11,2
2,4 - 15,6
0,53 -2,41 - 4,30
4,65
4,36
A+
3.047
RAV-GP1401AT8-ERAV-RM1401UTP-E
12,5
2,6 - 14,0
0,66 - 3,42 - 4,40
3,65
7,01
TBD
1.069
14,0
2,4 - 18,0
0,53 -3,41 - 5,50
4,11
4,36
TBD
3.049
RAV-GP1601AT8-ERAV-RM1601UTP-E
14,0
2,6 - 16,0
0,66 - 4,34 - 5,70
3,23
6,72
TBD
1.249
16,0
2,4 - 19,0
0,53 -4,28 - 6,51
3,74
4,36
TBD
3.049
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Performance data with Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (4-way Cassette)
RAV-GM561ATP-ERAV-RM561UTP-E
5
1,5 - 5,6
0,26 -1,56 - 1,86
3,21
6,34
A++
276
5,3
1,5 - 6,3
0,26 -1,36 - 2,08
3,90
4,60
A++
852
RAV-GM801ATP-ERAV-RM801UTP-E
6,7
1,5 - 8,0
0,26 - 2,22 - 2,60
3,02
5,81
A+
403
7,7
1,5 - 9,0
0,26 -2,13- 3,03
3,62
4,42
A+
1.615
RAV-GM901ATP-ERAV-RM901UTP-E
8,0
1,9 - 8,8
2,42
3,30
7,00
A++
389
9,0
1,6 - 9,9
2,65
3,72
4,60
A++
1.917
RAV-GM1101ATP-ERAV-RM1101UTP-E
9,5
3,0 - 11,2
0,60 - 2,87- 4,10
3,31
6,15
A++
540
11,2
3,0 - 13,0
0,60 -2,93 - 4,30
3,82
4,28
A+
2.615
RAV-GM1101AT8P-ERAV-RM1101UTP-E
9,5
3,0 - 11,2
0,60 - 2,87 - 4,10
3,31
6,15
A++
540
11,2
3,0 - 13,0
0,60 -2,93 - 4,30
3,82
4,28
A+
2.615
RAV-GM1401ATP-ERAV-RM1401UTP-E
12
3,0 - 13,2
0,60 -4,29 - 4,71
2,8
5,71
A+
736
13,0
3,0 - 16,0
0,60 - 3,46 - 4,50
3,76
4,29
A+
2.611
RAV-GM1401AT8P-ERAV-RM1401UTP-E
12
3,0 - 13,2
0,60 -4,29 - 4,71
2,8
5,71
A+
736
13,0
3,0 - 16,0
0,60 - 3,46 - 4,50
3,76
4,29
A+
2.611
RAV-GM1601ATP-ERAV-RM1601UTP-E
14,0
3,0 - 16,0
4,49
3,12
6,3
TBD
1.033
16,0
3,0 - 18,0
4,43
3,61
4,35
TBD
2.575
RAV-GM1601AT8P-ERAV-RM1601UTP-E
14,0
3,0 - 16,0
4,49
3,12
6,3
TBD
1.033
16,0
3,0 - 18,0
4,43
3,61
4,35
TBD
2.575
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Physical data indoor
m3/h - l/s
dB(A)
dB(A)
mm
kg
mm
kg
Indoor unit RAV-RM561UTP-E
1.050/780 - 291/217
32-29-28
47-44-43
256×840×840
20
30×950×950
4,2
RAV-RM801UTP-E
1.230/810 - 341/225
35-31-28
50-46-43
256×840×840
20
30×950×950
4,2
RAV-RM1101UTP-E
2.010/1170 - 558/325
43-38-33
58-53-48
319×840×840
24
30×950×950
4,2
RAV-GM901UTP-E
1.600/900 - 444/250
40-36-33
55-51-48
319×840×840
24
30×950×950
4,2
RAV-RM1601UTP-E
2.130/1260 - 592/350
45-40-36
60-55-51
319×840×840
24
30×950×950
4,2
RAV-RM1401UTP-E
2.100/1230 - 583/341
44-38-34
59-53-49
319×840×840
24
30×950×950
4,2
Air Flow (H/L)
Sound pressure level (H-M-L)
Sound power level (H-M-L)
Dimensions (HxWxD)
Weight
Panel dimensions (HxWxD)
Panel weight
C = cooling mode H = heating mode
4,7
SCOP MAX
The compact 4 way cassette is ideal for small commercial application where a compact efficient unit is needed.
Occupancy sensor switches off automatically the unit if nobody is in the room to save energy.*
DESIGN► Elegant and flat appearance► Fit within the T-bar of grid ceiling: 620mmX620mm
COMFORT► Individual setting of louver position: 3 different swing modes: standard, diagonally, opposite, turn around► 5 steps air flow
EASY INSTALLATION► Compact and thin chassis with only 256mm height► Built-in high-lift drain pump► Light-weight unit, for easy and quick installation
2,5kW-5,6kW
CAPACITY
-27°C/+52°C
OPERATION
30
*optional
Performance data with Super Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (600X600 Cassette)
RAV-GP561ATP-ERAV-RM561MUT-E
5,0
1,2-5,6
0,19 -1,56 -1,97
3,21
6,02
A+
291
5,6
0,9-7,0
0,16 - 1,60 - 2,36
3,50
4,30
A+
1.237
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Performance data with Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (600X600 Cassette)
RAV-GM301ATP-ERAV- RM301MUT-E
2,5
0,9 - 3,0
0,25 - 0,59 - 0,82
4,24
5,94
A+
147
3,4
0,8 - 4,5
0,17 - 0,76 - 1,40
4,47
4,70
A++
685
RAV-GM401ATP-ERAV- RM401MUT-E
3,6
0,9 - 4,0
0,18 - 0,90 - 2,00
4,00
5,76
A+
219
4,0
0,8 - 5,0
0,14 - 0,95 - 1,70
4,21
4,44
A+
851
RAV-GM561ATP-ERAV- RM561MUT-E
5,0
1,5 - 5,6
0,30 - 1,64 - 1,86
3,05
5,69
A+
307
5,3
1,5 - 6,3
0,30 - 1,47 - 2,40
3,61
4,37
A+
897
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Physical data indoor
m3/h - l/s
dB(A)
dB(A)
mm
kg
mm
kg
Indoor unit RAV- RM301MUT-E
640/440 - 177/122
38 - 36 - 30
53 - 51 - 45
256x575x575
15
12x620x620
2,5
RAV- RM401MUT-E
660/468 - 183/130
41 - 36 - 32
56 - 51 - 47
256x575x575
15
12x620x620
2,5
RAV- RM561MUT-E
798/546 - 221/152
44 - 39 - 35
59 - 54 - 50
256x575x575
15
12x620x620
2,5
Air Flow (H/L)
Sound pressure level (H-M-L)
Sound power level (H-M-L)
Dimensions (HxWxD)
Weight
Panel dimensions (HxWxD)
Panel weight
C = cooling mode H = heating mode
H-M-L = High - Medium - Low speed
31
RM_MUT COMPACT 4-WAY CASSETTE
4,81
SCOP MAX
Whatever the shape of the room, this flexible model ensures a uniform temperature and air distribution for optimal end user comfort.
Airzone compatibility: multiple individual controlled rooms with only one indoor unit.
ADAPTABILITY► Up to 120Pa available pressure, thanks to DC fan motor► Flexible design allows the inlet air to be configured between the standard rear inlet design or as an alternative, from the underside of the unit. There is also a provision for a fresh air intake supply via a pre-punched knockout hole► Compact and thin chassis, measuring just 275mm in height
EASY INSTALLATION► Built-in high-lift drain pump► PC board panel easily accessible from the side of the unit► Optional air discharge spigot
5kW-16kW
CAPACITY
-27°C/+52°C
OPERATION
COMPATIBLE WITH
32
Performance data with Super Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Standard Duct)
RAV-GP561ATP-ERAV-RM561BTP-E
5,0
1,2-5,6
0,19 - 1,52 - 1,99
3,29
5,60
A+
312
5,6
0,9-7,4
0,16 - 1,61 - 2,76
3,48
4,24
A+
1.254
RAV-GP801AT-ERAV-RM801BTP-E
7,1
1,9 - 8,0
0,26 - 1,63 - 3,20
4,36
7,50
A++
331
8,0
1,3 - 11,3
0,20 - 1,85 - 3,55
4,32
4,81
A++
1.484
RAV-GP1101AT-ERAV-RM1101BTP-E
10,0
3,1 - 12,0
0,65 - 2,40 - 3,63
4,17
6,60
A++
530
11,2
2,6 - 13,0
0,47 - 2,73 - 3,38
4,10
4,24
A+
3.032
RAV-GP1401AT-ERAV-RM1401BTP-E
12,5
3,1 - 14,0
0,65 - 3,57 - 3,97
3,50
6,06
TBD
1.237
14,0
2,6 - 16,5
0,47 - 3,63 - 4,43
3,86
4,24
TBD
3.168
RAV-GP1101AT8-ERAV-RM1101BTP-E
10,0
2,6 - 12,0
0,66 - 2,58 - 4,01
3,88
5,70
A+
613
11,2
2,40 - 15,6
0,53 - 2,76 - 4,42
4,06
4,14
A+
3.644
RAV-GP1401AT8-ERAV-RM1401BTP-E
12,5
2,6 - 14,0
0,66 - 3,81 - 4,89
3,28
5,48
TBD
1.366
14,0
2,40 - 18,0
0,53 - 3,66 - 5,71
3,83
3,95
TBD
4.176
RAV-GP1601AT8-ERAV-RM1601BTP-E
14,0
2,6 - 16,0
0,66 - 4,49 - 6,50
3,12
5,36
TBD
1.566
16
2,4 - 19,0
0,53 - 4,57 - 6,96
3,50
3,93
TBD
4.271
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Performance data with Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Standard Duct)
RAV-GM561ATP-ERAV-RM561BTP-E
5,0
1,5 - 5,6
0,31 - 1,83 - 2,05
2,73
5,28
A
332
5,3
1,5 - 6,3
0,31 - 1,62 - 2,47
3,27
4,08
A+
960
RAV-GM801ATP-ERAV-RM801BTP-E
6,7
1,5 - 7,4
0,31 -2,38 - 2,76
2,82
5,20
A
451
7,7
1,5 - 9,0
0,31 -2,32 - 3,18
3,32
4,13
A+
1.728
RAV-GM901ATP-ERAV-GM901BTP-E
8,0
1,9 - 8,8
2,67
3,00
6,10
A++
459
9,0
1,6 - 9,9
2,65
3,40
4,60
A++
1.917
RAV-GM1101ATP-ERAV-RM1101BTP-E
9,5
3,0 - 11,2
0,60 - 2,99 - 4,50
3,18
5,28
A
629
11,2
3,0 - 13,0
0,60 - 2,99 - 4,00
3,75
4,19
A+
2.537
RAV-GM1101AT8P-ERAV-RM1101BTP-E
9,5
3,0 - 11,2
0,60 - 2,99 - 4,50
3,18
5,28
A
629
11,2
3,0 - 13,0
0,60 - 2,99 - 4,00
3,75
4,19
A+
2.537
RAV-GM1401ATP-ERAV-RM1401BTP-E
12,1
3,0 - 13,2
0,60 - 4,42 - 4,71
2,74
5,36
TBD
TBD
13,0
3,0 - 16,0
0,60 - 3,60 - 4,55
3,61
4,19
TBD
TBD
RAV-GM1401AT8P-ERAV-RM1401BTP-E
12,1
3,0 - 13,2
0,60 - 4,42 - 4,71
2,74
5,36
TBD
TBD
13,0
3,0 - 16,0
0,60 - 3,60 - 4,55
3,61
4,19
TBD
TBD
RAV-GM1601ATP-ERAV-RM1601BTP-E
14,0
3,0 - 16,0
5,13
2,73
5,3
TBD
1.584
16,0
3,0 - 18,0
4,69
3,41
3,9
TBD
2.872
RAV-GM1601AT8P-ERAV-RM1601BTP-E
14,0
3,0 - 16,0
5,13
2,73
5,3
TBD
1.584
16,0
3,0 - 18,0
4,69
3,41
3,9
TBD
2.872
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Physical data indoor
m3/h - l/s
dB(A)
dB(A)
mm
kg
Pa
Indoor unit RAV-RM561BTP-E
800/480 - 222/133
33-29-25
48-44-40
275x700x750
23
30/120
RAV-RM801BTP-E
1.200/720 - 333/200
34-30-26
49-45-41
275x1.000x750
30
30/120
RAV-GM901BTP-E
1.700/1.000 - 472/278
37-33-30
52-48-45
275x1.400x750
40
50/120
RAV-RM1101BTP-E
2.100/1.260 - 583/350
40-36-33
55-51-48
275x1.400x750
40
50/120
RAV-RM1601BTP-E
2.100/1.260 - 583/350
40-36-33
55-51-48
275x1.400x750
40
50/120
RAV-RM1401BTP-E
2.100/1.260 - 583/350
40-36-33
55-51-48
275x1.400x750
40
50/120
Air Flow (H/L)
Sound pressure level (H-M-L)*
Sound power level (H-M-L)*
Dimensions (HxWxD)
Weight
External static pressure (stand/upper limit)
C = cooling mode H = heating mode
* bottom air inlet
33
RM_BTP STANDARD DUCT
4,6
SCOP MAX
Whether installed in a ceiling void or in a false ceiling, Toshiba’s slim duct offers the ultimate technology, with exceptional energy savings, high performance and easy installation.
Cleaned prefilter included compatible with rear or underside air suction.
ADAPTABILITY► Up to 50Pa available pressure with four steps set up► Easy to combine with different types of air diffusers► Flexible design, allows the inlet air to be configured between the standard rear inlet design or as an alternative, from the underside of the unit► There is also a provision for a fresh air intake supply via a pre-punched knockout hole
EASY INSTALLATION► Slimline design, with a height of just 21cm and a weight of 22kg, gives increased flexibility when designing and installing the system► Natural drain discharge or built-in drain pump to manage condensates
2,5kW-5,6kW
CAPACITY
-27°C/+52°C
OPERATION
34
Performance data with Super Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Slim duct)
RAV-GP561ATP-ERAV-RM561SDT-E
5,0
1,2-5,6
0,19 -1,56 - 1,98
3,21
5,77
A+
303
5,6
0,9-7,0
0,16 - 1,58 - 2,66
3,54
4,20
A+
1.266
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Performance data with Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Slim duct)
RAV-GM301ATP-ERAV- RM301SDT-E
2,5
0,9 - 3,0
0,25 - 0,56 - 0,82
4,46
6,29
A++
143
3,4
0,8 - 4,5
0,17 - 0,86 - 1,40
3,95
4,6
A++
907
RAV-GM401ATP-ERAV- RM401SDT-E
3,6
0,9 - 4,0
0,18 - 0,93 - 2,00
3,87
5,86
A+
227
4,0
0,8 - 5,0
0,14 - 0,97 - 1,70
4,12
4,01
A+
1.337
RAV-GM561ATP-ERAV-RM561SDT-E
5,0
1,5 - 5,6
0,32 - 1,91 - 2,75
2,62
5,14
A+
346
5,3
1,5 - 6,3
0,32 - 1,50 - 2,40
3,53
4,16
A+
1.517
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Physical data indoor
m3/h - l/s
dB(A)
dB(A)
mm
kg
Pa
Indoor unit RAV- RM301SDT-E
660/480 - 183/133
39-36-33
51-48-44
210x845x645
22
30(45-5)
RAV- RM401SDT-E
690/522 - 192/145
39-36-33
52-48-44
210x845x645
22
30(45-5)
RAV-RM561SDT-E
780/582 - 217/162
45-40-36
55-53-48
210x845x645
22
29(44-4)
Air Flow (H/L)
Sound pressure level (H-M-L)*
Sound power level (H-M-L)
Dimensions (HxWxD)
Weight
External static pressure standard (Upper-Lower)
C = cooling mode H = heating mode
* bottom air inlet
35
RM_SDT SLIM DUCT
3,51
SCOP MAX
Toshiba’s high static pressure ducts are specifically designed for large open spaces, due to their impressive air flow characteristics.
The DTP high static duct is compatible with textile duct diffusion system to blow the air smoothly all over the treated room.
COMFORT► 3-speed DC fan motor provides the correct air flow, whilst maximizing energy savings► Compatible with metal or textile duct
ADAPTABILITY► Designed to be lightweight, making the installation process quick and easy► With 7 step settings the static pressure of the system can range from 50 to 250Pa► Up to 5.600m3/h air flow to blow the air into large rooms
EASY INSTALLATION► Electronic components accessible from outside the unit► Air filter and drain pump available as an option
20kW-27kW-
CAPACITY
-27°C/+52°C
OPERATION
36
Performance data with Big DI Inverter
kW
kW
kW
W/W
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (High Static duct)
RAV-GM2241AT8-ERAV-RM2241DTP-E
19,0
4,6 - 22,4
1,27 - 5,86 - 9,05
3,24
4,62
TBD
2.468
22,4
4,6 - 25,0
1,27 - 5,71 - 10,15
3,92
3,51
TBD
7.174
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
RAV-GM2801AT8-ERAV-RM2801DTP-E
22,5
4,6 - 27,0
1,27 - 7,98 - 11,87
2,82
4,61
TBD
2.928
27,0
4,6 - 31,5
1,27 - 7,52 - 13,83
3,59
3,44
TBD
8.136
Physical data indoor
m3/h - l/s
dB(A)
dB(A)
mm
kg
Pa
Indoor unit RAV-RM2241DTP-E
3.800 - 1.055
44
79
448x1400x900
97
250/150/50,0
RAV-RM2801DTP-E
4.800 - 1.333
46
81
448x1400x900
97
250/150/50,0
Air Flow
Sound pressure level (back)
Sound power level (back)
Dimensions (HxWxD)
Weight
Upper limit/middle/standard
C = cooling mode H = heating mode
37
RM_DTP HIGH STATIC DUCT
4,41
SCOP MAX
Toshiba floor standing unit combines important air flow, wide air diffusion and simplified installation to cool and heat large rooms.
Embedded leak detector linked to safety ventilation to facilitate the integration of the product in every kind of projects.
WIDE ADAPTABILITY► Broad capacity lineup from 2 to 6HP► Connectable in monosplit or twin mode
COMFORT► Wide air flow to cool and heat large areas► Horizontal and vertical louvers for optimum air distribution
EASY INSTALLATION► Directly positioned on the floor to simplify installation► Plug and play product with embedded controller
5kW-16kW
CAPACITY
-27°C/+52°C
OPERATION
38
Performance data with Super Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Standard Duct)
RAV-GP561ATP-ERAV-RM561FT-EN
5,0
1,2-5,6
0,19-1,42-2,0
3,51
5,75
A+
304
5,6
0,9-7,0
0,16-1,65-2,80
3,39
4,2
A+
1.266
RAV-GP801AT-ERAV-RM801FT-EN
7,1
1,9 - 8,0
0,26-2,04-3,32
3,48
6,24
A++
398
8,0
1,3 - 11,3
0,2-2,37-3,75
3,38
4,41
A+
1.618
RAV-GP1101AT-ERAV-RM1101FT-EN
10,0
3,1 - 12,0
0,6-2,39-3,65
4,18
6,67
A++
524
11,2
2,6 - 13,0
0,42-2,76-3,85
4,06
4,37
A+
2.942
RAV-GP1601AT8-ERAV-RM1601FT-EN
14,0
2,6 - 16,0
0,66-4,39-6,5
3,19
5,55
TBD
1.513
16
2,4 - 19,0
0,53-4,83-6,96
3,31
3,96
TBD
4.238
RAV-GP1401AT8-ERAV-RM1401FT-EN
12,5
2,6 - 14,0
0,66-3,61-4,91
3,46
5,65
TBD
1.326
14,0
2,40 - 18,0
0,53-3,81-5,95
3,67
4,00
TBD
4.130
RAV-GP1101AT8-ERAV-RM1101FT-EN
10,0
2,6 - 12,0
0,66-2,46-4,1
4,07
5,86
A+
597
11,2
2,4 - 14,0
0,53-2,77-4,8
4,04
4,00
A+
3.774
RAV-GP1401AT-ERAV-RM1401FT-EN
12,5
3,1 - 14,0
0,6-3,52-4,07
3,55
6,1
TBD
1.229
14,0
2,6 - 16,5
0,42-3,97-4,61
3,53
4,35
TBD
3.086
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Performance data with Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Standard Duct)
RAV-GM561ATP-ERAV-RM561FT-EN/ES
5,0
1,5 - 5,6
0,30-1,79-2,34
2,79
5,15
A
340
5,3
1,5 - 6,3
0,30-1,72-2,47
3,08
4
A+
980
RAV-GM801ATP-ERAV-RM801FT-EN
6,7
1,5 - 7,4
0,31-3,18-3,31
2,11
4,89
B
479
7,7
1,5 - 9,0
0,31-3,20-3,45
2,41
3,81
A
1.727
RAV-GM1101ATP-ERAV-RM1101FT-EN
9,5
3,0 - 11,2
0,60-3,06-4,30
3,1
5,16
A
644
11,2
3,0 - 13,0
0,60-3,19-4,50
3,51
3,92
A
2.711
RAV-GM1101AT8P-ERAV-RM1101FT-EN
9,5
3,0 - 11,2
0,60-3,06-4,30
3,1
5,16
A
644
11,2
3,0 - 13,0
0,60-3,19-4,50
3,51
3,92
A
2.711
RAV-GM1401ATP-ERAV-RM1401FT-EN
12,1
3,0 - 13,2
0,60-4,71-4,83
2,57
4,86
TBD
1.492
13
3,0 - 16,0
0,60-4,01-4,80
3,24
3,9
TBD
2.727
RAV-GM1401AT8P-ERAV-RM1401FT-EN
12,1
3,0 - 13,2
0,60-4,71-4,83
2,57
4,86
TBD
1.492
13
3,0 - 16,0
0,60-4,01-4,80
3,24
3,9
TBD
2.727
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Physical data indoor
m3/h - l/s
dB(A)
dB(A)
mm
kg
Pa
Indoor unit RAV-RM561FT-EN/ES
820/600 - 228/167
46-42-38
60-56-52
1.750x600x210
44
TBD
RAV-RM801FT-EN
930/640 - 258/178
50-45-41
64-60-54
1.750x600x210
45
TBD
RAV-RM1101FT-EN
1.660/1.190 - 461/331
51-46-41
65-61-55
1.750x600x390
59
TBD
RAV-RM1401FT-EN
1.760/1.350 - 489/375
53-48-45
67-62-59
1.750x600x390
59
TBD
RAV-RM1601FT-EN
1.760/1.350 - 489/375
53-48-45
67-62-59
1.750x600x390
59
TBD
Air Flow (H/L)
Sound pressure level (H-M-L)*
Sound power level (H-M-L)*
Dimensions (HxWxD)
Weight
External static pressure(stand/upper limit)
C = cooling mode H = heating mode
39
RM_FT FLOOR STANDING
40
5,05
SCOP MAX
The simple, yet elegant design creates a pleasant and relaxing environment, quickly conditioning the room air to the desired temperature.
The airflow angle is automatically set to the most suitable setting according to the cooling or heating needs.
COMFORT► Automatic louver control for all year-round comfort and efficiency► Low noise levels, thanks to high diameter fan and DC motor
RELIABILITY► Self-cleaning function enables the air flow to remain constant and fresh and reduces the frequency of service visits
EASY TO INSTALL & TO MAINTAIN► This design represents the best possible solution, where there is a lack of space or absence of a ceiling void
ADAPTABILITY► Anti-bacterial drain points available as an option► Connecting kit available as an option for external I/O without local relay preparation
3,6kW-16kW
CAPACITY
-27°C/+52°C
OPERATION
41
RM_CTP CEILING
Performance data with Super Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Ceiling)
RAV-GP561ATP-ERAV-RM561CTP-E
5,0
1,2-5,6
0,19-1,37-1,98
3,65
6,76
A++
259
5,6
0,9-7,4
0,16-1,39-2,67
4,03
4,70
A++
1.130
RAV-GP801AT-ERAV-RM801CTP-E
7,1
1,9 - 8,0
0,26-1,60-3,17
4,44
7,95
A++
312
8,0
1,3 - 11,3
0,20-1,80-3,55
4,44
5,05
A++
1.412
RAV-GP1101AT-ERAV-RM1101CTP-E
10,0
3,1 - 12,0
0,55-2,23-3,45
4,48
8,23
A++
425
11,2
2,6 - 13,0
0,41-2,38-3,09
4,71
4,72
A++
2.726
RAV-GP1601AT8-ERAV-RM1601CTP-E
14,0
2,6 - 16,0
0,66 - 4,60 - 6,33
3,04
6,00
TBD
1400
16
2,4 - 19,0
0,53 - 4,30 - 6,96
3,72
3,93
TBD
4.003
RAV-GP1401AT8-ERAV-RM1401CTP-E
12,5
2,6 - 14,0
0,66 - 3,68 - 4,85
3,40
6,30
TBD
1190
14,0
2,40 - 18,0
0,53 - 3,48 - 5,95
4,02
3,94
TBD
3.931
RAV-GP1101AT8-ERAV-RM1101CTP-E
10,0
2,6 - 12,0
0,66 - 2,56 - 3,81
3,91
6,61
A++
529
11,2
2,4 - 14,0
0,53 - 2,51 - 4,26
4,46
4,21
A+
3.854
RAV-GP1401AT-ERAV-RM1401CTP-E
12,5
3,1 - 14,0
0,55-3,58-3,97
3,49
7,58
TBD
989
14,0
2,6 - 16,5
0,41-3,59-4,40
3,90
4,71
TBD
2.852
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Performance data with Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (Ceiling)
RAV-GM401ATP-ERAV-RM401CTP-E
3,6
0,9 - 4,0
0,18 - 0,83 - 2,00
4,34
6,34
A++
199
4,0
0,8 - 5,0
0,14 - 0,78 - 1,70
5,13
5,1
A+++
741
RAV-GM561ATP-ERAV-RM561CTP-E
5,0
1,5 - 5,6
0,29-1,61-1.95
3,11
5,5
A
318
5,3
1,5 - 6,3
0,29-1,36-2,40
3,90
4,32
A+
908
RAV-GM901ATP-ERAV-GM901CTP-E
8,0
1,9 - 8,8
2,58
3,10
6,10
A++
459
9,0
1,6 - 9,9
2,65
3,40
4,60
A++
1.917
RAV-GM801ATP-ERAV-RM801CTP-E
6,9
1,5 - 7,4
0,29-2,38-2,76
2,90
5,62
A+
429
7,7
1,5 - 9,0
0,29-2,13-3,20
3,62
4,11
A+
1.697
RAV-GM1101ATP-ERAV-RM1101CTP-E
9,5
3,0 - 11,2
0,60-2,95-4,10
3,22
5,86
A+
567
11,2
3,0 - 12,5
0,60-2,94-4,10
3,81
4,27
A+
2.490
RAV-GM1101AT8P-ERAV-RM1101CTP-E
9,5
3,0 - 11,2
0,60-2,95-4,10
3,22
5,86
A+
604
11,2
3,0 - 12,5
0,60-2,94-4,10
3,81
4,27
A+
2.490
RAV-GM1601ATP-ERAV-RM1601CTP-E
14,0
3,0 - 16,0
4,65
3,01
5,9
TBD
1.423
16,0
3,0 - 18,0
4,69
3,9
4,35
TBD
2.732
RAV-GM1601AT8P-ERAV-RM1601CTP-E
14,0
3,0 - 16,0
4,65
3,01
5,9
TBD
1.423
16,0
3,0 - 18,0
4,69
3,9
4,35
TBD
2.732
RAV-GM1401ATP-ERAV-RM1401CTP-E
12,1
3,0 - 13,2
0,60-4,42-4.71
2,74
5,36
TBD
TBD
13,0
3,0 - 16,0
0,60-3,48-4,60
3,73
4,19
TBD
TBD
RAV-GM1401AT8P-ERAV-RM1401CTP-E
12,1
3,0 - 13,2
0,60-4,42-4,71
2,74
5,36
TBD
TBD
13,0
3,0 - 16,0
0,60-3,48-4,60
3,73
4,19
TBD
TBD
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
Physical data indoor
m3/h - l/s
dB(A)
dB(A)
mm
kg
Indoor unit RAV-RM401CTP-E
900/540 - 250/150
37-35-28
52-50-43
235x950x690
23
RAV-RM561CTP-E
900/540 - 250/150
37-35-28
52-50-43
235x950x690
23
RAV-RM801CTP-E
1.410/750 - 392/208
41-36-29
56-51-44
235x1.270x690
29
RAV-GM901CTP-E
1.600/900 - 444/250
42-38-30
57-53-45
235x1.586x690
37
RAV-RM1101CTP-E
1.860/1.020 - 517/283
44-38-32
59-53-47
235x1.586x690
37
RAV-RM1601CTP-E
2.100/1.260 - 583/350
40-36-33
55-51-48
275x1.400x750
40
RAV-RM1401CTP-E
2.040/1.200 - 567/333
46-41-35
61-56-50
235x1.586x690
37
Air Flow (H/L)
Sound pressure level (H-M-L)
Sound power level (H)
Dimensions (HxWxD)
Weight
C = cooling mode H = heating mode
4,41
SCOP MAX
Compact, quiet with an attractive design, this high wall is suitable for every kind of project in new construction or refurbishment.
Comfort sleep function adjusts automatically the room temperature and the fan speed.
COMFORT► Auto louver mode allows optimum and uniform air distribution
CONTROL► Wireless remote control with pre-set functions accessible with dedicated buttons: hi-power mode, quiet mode, comfort sleep, eco-mode
HEALTHY► Self-cleaning feature to prevent mould formation on the heat exchanger coils
0,9-12kW
CAPACITY
-20°C/+46°C
OPERATION
42
Performance data with Super Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (High-Wall)
RAV-GP561ATP-ERAV-RM561KRTP-E
5,0
1,2 - 5,6
0,19 - 1,43 -1,98
3,50
7,59
A++
230
5,6
0,9 - 7,3
0,16 - 1,39 - 2,67
4,03
4,17
A+
1.274
RAV-GP1101AT-ERAV-GM1101KRTP-E
10,0
3.1- 12.0
0,55-2,77-3,90
3,61
7,2
A++
486
11,2
2,6- 13,0
0,52-3,13-4,40
3,58
4,41
A+
2.920
10,0
2,6 - 12,0
2,86
3,50
6,35
A++
551
11,2
2,4 - 13,0
3,25
3,45
4,21
A+
3.591
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
RAV-GP1101AT8-ERAV-GM1101KRTP-E
RAV-GP801ATP-ERAV-RM801KRTP-E
7,1
1,9 - 8,0
0,26 - 2,06 - 3,17
3,45
7,34
A++
338
8,0
1,3 - 11,3
0,20 - 2,25 - 3,50
3,56
4,13
A+
1.725
Performance data with Digital Inverter
kW
kW
kW
kWh/a
kW
kW
kW
W/W
kWh/a
C
C
C
H
H
H
Outdoor unitIndoor unit (High-Wall)
RAV-GM301ATP-ERAV-RM301KRTP-E
2,5
0,9 - 3,0
0,25 - 0,61 - 0,82
4,10
6,36
A++
138
3,4
0,8 - 4,5
0,17 - 0,85 - 1,40
4,00
4,10
A+
887
Cooling capacity
Cooling range (min. - max.)
Power input (min. - rated - max.)
EER
SEER
Energy efficiency class
Seasonal electricity consumption
Heating capacity
Heating range (min. - max.)
Power input (min. - rated - max.)
COP
SCOP
Energy efficiency class
Seasonal electricity consumption
RAV-GM401ATP-ERAV-RM401KRTP-E
3,6
0,9 - 4,0
0,18 - 1,13 - 2,00
3,19
6,12
A++
206
4,0
0,8 - 5,0
0,14 - 1,12 - 1,70
3,57
4,22
A+
895
RAV-GM561ATP-ERAV-RM561KRTP-E
5,0
1,5 - 5,6
0,30 - 1,66 - 1,86
3,01
6,19
A++
383
5,3
1,5 - 6,3
0,30 - 1,55 - 2,40
3,42
4,00
A+
980
RAV-GM801ATP-ERAV-RM801KRTP-E
6,7
1,5 - 8,0
0,31- 2,44 - 2,85
2,75
5,73
A+
409
7,7
1,5 - 9,0
0,31 - 2,61 - 3,30
2,95
4,01
A+
1.780
RAV-GM901ATP-ERAV-GM901KRTP-E
8,0
1,9 - 8,8
2,67
3,00
6,10
A++
459
9,0
1,6 - 9,9
2,9
3,10
4,10
A+
2.151
RAV-GM1101ATP-ERAV-GM1101KRTP-E
9,5
3,0 - 11,2
0,60 - 2,97 - 4,30
3,20
6,10
A++
545
11,2
3,0 - 13,0
0,60 - 3,47 - 4,70
3,23
4,20
A+
2.665
RAV-GM1101AT8P-ERAV-GM1101KRTP-E
9,5
3,0 - 11,2
0,60 - 2,97 - 4,30
3,20
6,10
A++
545
11,2
3,0 - 13,0
0,60 - 3,47 - 4,70
3,23
4,20
A+
2.664
Physical data indoor
m3/h - l/s
dB(A)
dB(A)
mm
kg
C
C
C
Indoor unit RAV-RM301KRTP-E
670/450 - 186/125
40-34-29
55-49-44
293x798x230
10
RAV-RM401KRTP-E
700/450 - 229/125
41-36-30
56-51-45
293x798x230
10
RAV-RM561KRTP-E
960/680 - 266/189
42-39-35
57-54-50
320x1.050x250
14
RAV-GM901KRTP-E
1.180/ 680 - 328/189
47-41-35
62-56-50
320x1.050x250
14
RAV-GM1101KRTP-E
1.610/1.180 - 447/328
49-45-41
64-60-56
348x1.200x280
19
RAV-RM801KRTP-E
1.040/680 - 289/189
45-41-35
60-56-50
320x1.050x250
14
Air Flow (H/L)
Sound pressure level (H-M-L)
Sound power level (H-M-L)
Dimensions (HxWxD)
Weight
C = cooling mode H = heating mode
43
RM_KRTP HIGH-WALL
5,05
SCOP MAX
Connect 2 indoor units on the same system to satisfy the cooling and heating requirements of larger area.
Toshiba RAV simplistic piping design allows multiple indoor units to be connected via a simple branching methodology.
COMFORT► Precise air flow control, accurately controls the distribution of the air regardless of the room size
ADAPTABILITY► Twin configuration with up to 50m piping length► Compatible with every type of LC indoor units: 4–way cassette, duct, high-wall and ceiling
CONTROL► One user-friendly controller for all the indoor units to simplify the control
9,5kW-14kW
CAPACITY
-27°C/+52°C
OPERATION
44
Twin split DI - Cooling
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
9,59,5
12,012,014,014,09,59,59,59,5
12,112,114,014,09,59,59,59,5
12,112,114,014,09,59,5
12,112,114,014,09,59,5
12,112,1
3,0 - 11,23,0 - 11,23,0 - 13,23,0 - 13,23,0 - 16,03,0 - 16,03,0 - 11,23,0 - 11,23,0 - 11,23,0 - 11,23,0 - 13,23,0 - 13,23,0 - 16,03,0 - 16,03,0 - 11,2 3,0 - 11,2 3,0 - 11,2 3,0 - 11,2 3,0 - 13,23,0 - 13,23,0 - 16,03,0 - 16,03,0 - 11,23,0 - 11,23,0 - 13,23,0 - 13,23,0 - 16,03,0 - 16,03,0 - 11,23,0 - 11,23,0 - 13,23,0 - 13,2
GM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-E
Indoor unitRAV-
RM561UTP-ERM561UTP-ERM801UTP-ERM801UTP-ERM801UTP-ERM801UTP-ERM561MUT-ERM561MUT-ERM561BTP-ERM561BTP-ERM801BTP-ERM801BTP-ERM801BTP-ERM801BTP-ERM561SDT-ERM561SDT-ERM561CTP-ERM561CTP-ERM801CTP-ERM801CTP-ERM801CTP-ERM801CTP-ERM561KRTP-ERM561KRTP-ERM801KRTP-ERM801KRTP-ERM801KRTP-ERM801KRTP-ERM561FT-EN/ESRM561FT-EN/ESRM801FT-EN/ESRM801FT-EN/ESRM801FT-EN/ESRM801FT-EN/ES
HP
4455664444556644445566445566445566
Power inputkW
2,872,874,294,294,494,493,003,002,992,994,424,425,135,133,033,032,952,954,424,424,654,652,982,984,714,715,095,093,063,064,714,71
EER
3,313,312,802,803,123,123,173,173,183,182,742,742,732,733,143,143,223,222,742,743,013,013,193,192,572,572,752,753,103,102,572,57
SEER
5,945,945,715,716,36,35,55,5
5,285,285,365,365,305,305,325,325,865,865,365,365,905,905,325,325,245,245,15,1
5,165,164,864,86
Energyclass
A+A+A+A+
TBDTBD
AAAA
TBDTBDTBDTBD
AA
A+A+
TBDTBDTBDTBD
AA
TBDTBDTBDTBD
AA
TBDTBD
4-way cassette
Compact4-way cassette
Ducted
Slim duct
Ceiling
High-wall
Floor standing
Twin split DI - Heating
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
11,211,213,013,016,016,011,211,211,211,213,013,016,016,011,211,211,211,213,013,016,016,011,211,213,013,016,016,011,211,213,013,0
3,0 - 13,03,0 - 13,0 3,0 - 16,0 3,0 - 16,03,0 - 18,03,0 - 18,03,0 - 13,03,0 - 13,03,0 - 13,03,0 - 13,0 3,0 - 16,0 3,0 - 16,03,0 - 18,03,0 - 18,03,0 - 13,03,0 - 13,03,0 - 13,03,0 - 13,0 3,0 - 16,0 3,0 - 16,03,0 - 18,03,0 - 18,03,0 - 13,03,0 - 13,0 3,0 - 16,0 3,0 - 16,03,0 - 18,03,0 - 18,03,0 - 13,03,0 - 13,03,0 - 16,03,0 - 16,0
GM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-EGM1101ATP-EGM1101AT8P-EGM1401ATP-EGM1401AT8P-EGM1601ATP-EGM1601AT8P-E
Indoor unitRAV-
RM561UTP-ERM561UTP-ERM801UTP-ERM801UTP-ERM801UTP-ERM801UTP-ERM561MUT-ERM561MUT-ERM561BTP-ERM561BTP-ERM801BTP-ERM801BTP-ERM801BTP-ERM801BTP-ERM561SDT-ERM561SDT-ERM561CTP-ERM561CTP-ERM801CTP-ERM801CTP-ERM801CTP-ERM801CTP-ERM561KRTP-ERM561KRTP-ERM801KRTP-ERM801KRTP-ERM801KRTP-ERM801KRTP-ERM561FT-EN/ESRM561FT-EN/ESRM801FT-EN/ESRM801FT-EN/ESRM801FT-EN/ESRM801FT-EN/ES
HP
4455664444556644445566445566445566
Power inputkW
2,932,933,463,464,434,433,263,262,992,993,603,604,694,692,992,992,942,943,483,484,614,612,992,993,863,864,984,983,193,194,014,01
COP
3,823,823,763,763,613,613,443,443,753,753,613,613,413,413,753,753,813,813,743,743,473,473,753,753,373,373,213,213,513,513,243,24
SCOP
4,284,284,294,294,354,354,024,024,224,224,214,213,473,474,194,194,284,284,194,194,104,104,194,194,194,19
44
3,923,923,903,9
Energyclass
A+A+A+A+
TBDTBDA+A+A+A+
TBDTBDTBDTBDA+A+A+A+
TBDTBDTBDTBDA+A+
TBDTBDTBDTBDA+A
TBDTBD
4-way cassette
Compact4-way cassette
Ducted
Slim duct
Ceiling
High-wall
Floor standing
SDI-DI TWIN
46
Triple split SDI - Cooling
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
1414141414
141414141414
14
3,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,0
3,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,03,0 - 16,0
3,0 - 16,0
GM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-E
Indoor unitRAV-
RM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-ERM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-E
HP
66666666666666
Power inputkW
4,494,965,134,984,65
5,094,494,965,134,984,65
5,09
EER
3,122,822,732,813,01
2,753,122,822,732,813,01
2,75
SEER
6,35,15,35,15,9
5,16,35,15,35,15,9
5,1
Energyclass
TBDTBDTBDTBDTBD
TBDTBDTBDTBDTBDTBD
TBD
4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall
Triple split SDI - Heating
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
1616161616
161616161616
16
3,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,0
3,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,03,0 - 18,0
3,0 - 18,0
GM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601ATP-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-EGM1601AT8P-E
Indoor unitRAV-
RM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-ERM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-E
HP
66666666666666
Power inputkW
4,434,694,694,694,61
4,984,434,694,694,694,61
4,8
COP
3,613,413,413,413,47
3,213,613,413,413,413,47
3,21
SCOP
4,354
3,94
4,1
44,35
43,94
4,1
4
Energyclass
TBDTBDTBDTBDTBD
TBDTBDTBDTBDTBDTBD
TBD
4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall
SDI-DI TWIN
Twin split SDI - Cooling
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
10,012,510,012,510,012,514,07,1
10,010,010,012,510,012,514,07,1
10,010,07,1
10,012,510,012,514,010,012,510,012,514,010,012.510,012,314,0
3,1-12,03,1-14,03,1-12,03,1-14,0
2,6 - 12,0 2,6 - 14,0 2,6 - 16,0
1,9-8,03,1-12,0
2,6 - 12,03,1-12,03,1-14,0
2,6 - 12,0 2,6 - 14,0 2,6 - 16,0
1,9-8,03,1-12,0
2,6 - 12,01,9-8,0
3,1-12,03,1-14,0
2,6 - 12,0 2,6 - 14,0 2,6 - 16,03,1-12,0
3,1 - 14,02,6 - 12,02,6 - 14,02,6 - 16,03,1-12,03,1-14,0
2,6 - 12,0 2,6 - 13,52,6 - 16,0
GP1101AT-EGP1401AT-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP801AT-EGP1101AT-EGP1101AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP801AT-EGP1101AT-EGP1101AT8-EGP801AT-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-E
Indoor unitRAV-
GM561UT-EGM801UT-ERM561UTP-ERM801UTP-ERM561UTP-ERM801UTP-ERM801UTP-ERM401MUT-ERM561MUT-ERM561MUT-ERM561BTP-ERM801BTP-ERM561BTP-ERM801BTP-ERM801BTP-ERM401SDT-ERM561SDT-ERM561SDT-ERM401CTP-ERM561CTP-ERM801CTP-ERM561CTP-ERM801CTP-ERM801CTP-ERM561FT-ERM801FT-ERM561FT-ERM801FT-ERM801FT-ERM561KRTP-ERM801KRTP-ERM561KRTP-ERM801KRTP-ERM801KRTP-E
HP
4545456344454563443454564545645456
Power inputkW
1,92,912,133,162,323,424,341,732,392,602,403,572,583,814,491,872,562,781,602,233,582,563,684,602,393,522,463,614,392,443,552,613,734,65
EER
5,264,3
4,693,964,313,653,234,104,183,854,173,503,883,283,123,803,913,604,444,483,493,913,403,044,183,554,073,463,194,1
3,453,833,303,01
SEER
8,648,198,578,147,067,066,767,807,706,166,746,275,815,645,506,506,655,607,827,977,346,546,175,896,676,075,885,655,558,156,696,356,105,88
Energyclass
A++TBDA++TBDA++TBDTBDA++A++A++A++TBDA+
TBDTBDA++A++A+
A++A++TBDA++TBDTBDA++TBDA+
TBDTBDA++TBDA++TBDTBD
Smart4-way cassette
4-way cassette
Compact 4-way cassette
Ducted
Slim duct
Ceiling
Floor standing
High-wall
Twin split SDI - Heating
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
11,214,011,214,011,214,016,08,0
11,211,211,214,011,214,016,08,0
11,211,28,0
11,214,0 11,214,016,011,214,011,214,016,011,214,011,214,016,0
2,6-13,02,6-16,52,6-13,02,6-16,5
2,4 - 15,62,4 - 18,02,4 - 19,01,3-11,32,6-13,0
2,4 - 14,02,6-13,02,6-16,5
2,4 - 15,62,4 - 18,02,4 - 19,01,3-11,32,6-13,0
2,4 - 14,01,3-11,32,6-13,02,6-16,5
2,4 - 14,02,4 - 18,02,4 - 19,02,6 - 13,02,6 - 16,52,4 - 14,02,4 - 18,02,4 - 19,02,6-13,02,6-16,5
2,4 - 14,02,4 - 18,02,4 - 19,0
GP1101AT-EGP1401AT-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP801AT-EGP1101AT-EGP1101AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP801AT-EGP1101AT-EGP1101AT8-EGP801AT-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-EGP1101AT-EGP1401AT-EGP1101AT8-EGP1401AT8-EGP1601AT8-E
Indoor unitRAV-
GM561UT-EGM801UT-ERM561UTP-ERM801UTP-ERM561UTP-ERM801UTP-ERM801UTP-ERM401MUT-ERM561MUT-ERM561MUT-ERM561BTP-ERM801BTP-ERM561BTP-ERM801BTP-ERM801BTP-ERM401SDT-ERM561SDT-ERM561SDT-ERM401CTP-ERM561CTP-ERM801CTP-ERM561CTP-ERM801CTP-ERM801CTP-ERM561FT-ERM801FT-ERM561FT-ERM801FT-ERM801FT-ERM561KRTP-ERM801KRTP-ERM561KRTP-ERM801KRTP-ERM801KRTP-E
HP
4545456344454563443454564545645456
Power inputkW
2,183,042,343,212,413,414,281,822,672,992,733,632,763,664,571,822,672,661,802,383,592,513,484,302,763,972,773,814,832,733,662,663,784,87
COP
5,144,614,794,364,654,113,744,404,193,744,103,864,063,833,504,404,194,214,444,713,904,464,023,724,063,534,043,673,314,103,664,213,703,29
SCOP
5,004,974,734,724,364,364,364,864,403,934,264,254,163,963,944,514,003,845,054,714,704,214,194,194,384,354,014,003,964,054,374,144,114,08
Energyclass
A++TBDA++TBDA+
TBDTBDA++A+A
A+TBD
ATBDTBDA+A+A
A++A++TBDA+
TBDTBDA+
TBDA+
TBDTBDA+
TBDA+
TBDTBD
Smart4-way cassette
4-way cassette
Compact 4-way cassette
Ducted
Slim duct
Ceiling
Floor standing
High-wall
48
Triple split SDI - Cooling
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
14141414141414
2,6 - 16,02,6 - 16,02,6 - 16,02,6 - 16,02,6 - 16,02,6 - 16,02,6 - 16,0
GP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-E
Indoor unitRAV-
RM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-E
HP
6666666
Power inputkW
4,344,244,494,304,604,394,65
EER
3,233,303,123,263,043,193,01
SEER
6,716,095,425,985,955,555,82
Energyclass
-------
4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall
Triple split SDI - Heating
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
16161616161616
2,4 - 19,0 2,4 - 19,0 2,4 - 19,0 2,4 - 19,0 2,4 - 19,0 2,4 - 19,0 2,4 - 19,0
GP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-EGP1601AT8-E
Indoor unitRAV-
RM561UTP-ERM561MUT-ERM561BTP-ERM561SDT-ERM561CTP-ERM561FT-ENRM561KRTP-E
HP
6666666
Power inputkW
4,284,564,574,574,304,834,87
COP
3,743,513,503,503.723,313,29
SCOP
4,364,133,944,074,193,964,08
Energyclass
-------
4-way cassetteCompact 4-way cassetteDuctedSlim ductCeilingFloor standingHigh-wall
Twin split Big-DI - Cooling
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
20,023,520,023,520,023,520,023,5
4,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,0
GM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-E
Indoor unitRAV-
RM1101UTP-ERM1401UTP-ERM1101BTP-ERM1401BTP-ERM1101FT-ENRM1401FT-ENRM1101CTP-ERM1401CTP-E
HP
8108
108
108
10
Power inputkW
5,567,836,178,876,178,876,178,97
EER
3,603,003,242,653,242,653,242,62
SEER
6,536,215,034,925,084,875,675,16
4-way cassette
Ducted
Floor standing
Ceiling
Twin split Big-DI - Heating
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
22,427,022,427,022,427,022,427,0
4,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,5
GM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-E
Indoor unitRAV-
RM1101UTP-ERM1401UTP-ERM1101BTP-ERM1401BTP-ERM1101FT-ENRM1401FT-ENRM1101CTP-ERM1401CTP-E
HP
8108
108
108
10
Power inputkW
5,307,105,577,465,638,215,717,56
COP
4,233,804,023,623,983,293,923,57
SCOP
4,053,903,723,643,603,573,793,65
4-way cassette
Ducted
Floor standing
Ceiling
SDI-DI TWIN
49
Triple split Big-DI - Cooling
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
20,023,520,023,520,023,520,0
23,5
20,0
23,5
4,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,04,6 - 22,44,6 - 27,04,6 - 22,4
4,6 - 27,0
4,6 - 22,4
4,6 - 27,0
GM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-E
GM2801AT8-E
GM2241AT8-EGM2801AT8-E
Indoor unitRAV-
RM801UTP-ERM801UTP-ERM801BTP-ERM801BTP-ERM801CTP-ERM801CTP-ERM801FT-EN
RM801FT-ENRM-801KRTP-E
RM-801KRTP-E
HP
8108
108
108
10
810
Power inputkW
5,567,836,178,876,178,876,17
8,87
6,67
9,22
EER
3,603,003,242,653,242,653,24
2,65
3,00
2,55
SEER
6,576,245,225,095,595,165,094,94
5,58
5,30
4-way cassette
Ducted
Ceiling
Floor standing
High-wall
Triple split Big-DI - Heating
Indoor unit model Outdoor unitRAV-
capacity nominal-kW min-max-kW
22,427,022,427,022,427,022,427,0
22,4
27,0
4,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,54,6 - 25,04,6 - 31,5
4,6 - 25,0
4,6 - 31,5
GM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-EGM2801AT8-EGM2241AT8-E
GM2801AT8-E
GM2241AT8-EGM2801AT8-E
Indoor unitRAV-
RM801UTP-ERM801UTP-ERM801BTP-ERM801BTP-ERM801CTP-ERM801CTP-ERM801FT-EN
RM801FT-ENRM-801KRTP-E
RM-801KRTP-E
HP
8108
108
108
10
810
Power inputkW
5,307,105,577,465,717,565,63
8,21
6,12
7,65
COP
4,233,804,023,623,923,573,98
3,29
3,66
3,53
SCOP
4,053,913,743,653,793,653,60
3,58
3,76
3,63
4-way cassette
Ducted
Ceiling
Floor standing
High-wall
Up to 5.000m3/h
MAX AIR FLOW
The DX kit enables connection of a third-party party air handling unit (with DX coil) to Toshiba LC outdoor units.
Input/output signal available:• Operation output• AC fan motor output• Alarm output• External On/Off input• Safety-cut output
FLEXIBILITY► Compatible with the majority of air handling units with a DX coil fitted inside (capacity ranges from 4,6 to 27kW)► Can operate in both heating and cooling modes, depending on end user requirements
CONTROL► Control achieved using a standard Toshiba remote controller► Algorithm based on air suction temperature
EASY TO INSTALL & MAINTAIN► Capacity set by DN code adjustment during installation► Extended 5 meters sensor leads pre-fitted to improve installation time and flexibility► Relay isolated inputs to prevent accidental wiring errors, damaging the PCB
4,1kW-27kW
CAPACITY
-27°C/+52°C
OPERATION
50
DX Kit Performances
kW
kW
kW
kW
m3/h
dm3
DX Controller unitOutdoor Unit Cooling CapacityRANGE
DXC0102 HP
RAV-SM564ATP-ERAV-SP564ATP-E
RAV-
DISDI
4,1 - 5,3 - 5,6
4,1 - 5,3 - 5,6
4,6 - 5,6 - 6,3
4,6 - 5,6 - 7,4
720-900-1.080
0,8 - 1,1
DXC0103 HP
RAV-SM804ATP-ERAV-SP804ATP-E
5,4 - 7,1 - 7,4
5,4 - 7,1 - 8,0
7,5 - 8,0 - 9,0
7,5 - 8,0 - 10,6
1.060-1.320-1.580
1,0 - 1,4
DXC0104 HP
RAV-SM1104ATP-ERAV-SP1104AT(8)-E1
7,2 - 10,0 - 11,2
7,2 - 10,0 - 12,0
8,1 - 11,2 - 12,5
8,1 - 11,2 - 13,0
1.280-1.600-1.920
1,5 - 2,1
DXC0105 HP
RAV-SM1404ATP-ERAV-SP1404AT(8)-E1
10,1 - 12,5 - 13,2
10,1 - 12,5 - 14,0
11,3 - 14,0 - 16,0
11,3 - 14,0 - 16,5
1.680-2.100-2.520
1,7 - 2,7
DXC0106 HP
RAV-SM1603AT-ERAV-SP1604AT8-E1
12,6 - 14,0 - 16,0
14,1 - 16,0 - 19,0
1.850-2.800-3.740
1,7 - 3,2
DXC0108 HP
RAV-SM2244AT8-E
14,1 - 20,0 - 22,4
16,1 - 22,4 - 25,0
2.880-3.600-4.320
3,0 - 4,2
DXC01010 HP
RAV-SM2804AT8-E
20,1 - 23,0 - 27,0
22,5 - 27,0 - 31,5
3.360-4.200-5.040
3,0 - 5,4
Cooling capacity (min-rated*-max) DI
Cooling capacity (min-rated*-max) SDI
Heating capacity (min-rated*-max) DI
Heating capacity (min-rated*-max) SDI
AHU Air Volume (min-rated*-max)
Coil Internal Volume (min-max)
Cooling & Heating output figures are based on calculations and “general” test data. All figures are to be taken as approximations. The properties of the third party DX Coil will have an affect on the performance of the outdoor units.All capacity data shown is based on the following Rated Conditions:• Cooling (Rated): Indoor air temperature 27°C db / 19°C wb. Outdoor air temperature 35°C db• Heating (Rated): Indoor air temperature 20°C db. Outdoor air temperature 7°C db / 6°C wb.
Notes:Cooling Mode Coil “Air On” Temp: Minimum 15°CWB (18°CDB) / Maximum 24°CWB (32°CDB)Air temperatures flowing across the coil below this level, can in some circumstances, cause icing and freezing issues with the coil and eventually forcing the system to shut down and also be detrimental to the outdoor unit itself.
Heating Mode Coil “Air On” Temp: Minimum 15°CDB / Maximum 28°CDBIn the reserve cycle mode when the outdoor unit is producing hot gas, the coil in the AHU is effectively the condenser. Air temperatures flowing across the coil below this level, can cause over condensing of the refrigerant.This can result in liquid being returned to the compressor which will cause a mechanical failure of the outdoor unit.Low air temperatures will also cause the unit to use it’s defrost mode more often.
Fresh Air IntakeIf you wish to use Fresh Air whish in outside of these Coil “Air On” limits it has to either be pre-conditioned by other equipment, or mixed with return air (or a combination of both) so that it remainsinside these limits, in order to ensure reliable operation.
Automatic ModePlease be aware that frequent mode changes could occur when using Automatic mode.
TA sensorThe TA sensor should be positioned in the return air duct. In case, it’s not representative enough of the occupants area temperature, remote temperature sensor TCB -TC21LE2 should be used in the room.
Physical dataDX Controller unit RAV-
mm
kg
°C
°C
V-ph-Hz
DXC010
400x300x150
10
15°CWB÷24°CWB
15°CDB÷28°CDB
220/240-1-50
Dimensions (HxWxD)
Weight
Operating range - Cooling coil "Air on" temp
Operating range - Heating coil "Air on" temp
Power supply
51
RAV-DXC STANDARD DX KIT
52
The DX kit enables connection and control of Toshiba LC outdoor units to a third-party air handling unit (with DX coil).
FLEXIBILITY► Compatible with the majority of air handling units with a DX coil fitted inside (capacity ranges from 4,6 to 27kW)► Air flow rate from 480 to 5.040m3/h
CONTROL► Capacity control and selection mode of the Toshiba outdoor unit directly from the AHU controller through a 0-10V signal
EASY TO INSTALL & MAINTAIN► Capacity set by DN code during installation► Extended 5 meters sensor leads pre-fitted to improve installation time and flexibility► Relay isolated inputs to prevent accidental wiring errors, damaging the PCB
Up to 4.200m3/h
MAX AIR FLOW
Compatible with both LC and VRF systems.(made possible via simple switch change on PCB).
2,5kW-27kW
CAPACITY
-27°C/+52°C
OPERATION
53
RBC-DXC 0-10V DX KIT
Technical Limitations:• Cooling & Heating output figures are based on calculations and “general” test data. All figures are to be taken as approximations. The properties of the 3rd Party DX Coil will have an effect on the performance of the Outdoor units.• The DX Coil must be suitable for R410A.• The design should allow operation as both an Evaporator and a Condenser (Features: Multiple circuits / Liquid Capillary Distributor / Gas Header).• The standard Air volume flow rate is a guideline. The required capacity should determine DX-Interface size selection.• The counter flow principle must be observed for the DX coil design.• A Drain Pan must be fitted (even if only used in Heat mode) due to defrost cycles.• It is recommended to fit droplet eliminator plates in the discharge air stream if used in Cool mode.• 1:1 Connection: The DX Interface (0-10V) must be connected 1:1 with Toshiba outdoor units.• Only Heating and Cooling Modes are available on the RBC-DXC031 (No Automatic or Fan Only).
Capacity table
kW
kW
HP
LC / VRF DX Coil Controller UnitDX PMV valve unit
DXC031
-
RBC-
2,5
3,4
1,0
DXC031
-
3,6
4,0
1,5
DXC031
-
5,0
5,3 SM (5,6 SP)
2,0
DXC031
-
6,7 SM (7,1 SP)
7,7 SM (8,0 SP)
3,0
DXC031
-
10,0
11,2
4,0
DXC031
-
12,1 SM (12,5 SP)
12,8 SM (14,0 SP)
5,0
DXC031
-
14,0
16,0
6,0
DXC031
-
20,0
22,4
8,0
DXC031
-
23,0
27,0
10,0
Cooling capacity
Heating capacity
Power code
Physical Data
m3/h
m3/h
mm
kg
m
m
m
m
IP
°C / RH
°C
°C
LC / VRF DX CoilController Unit
DXC031RBC-
480
660
400x300x150
8
200
100
500
500
65
5-40 / 10-90
15°CWB÷24°CWB
5°CDB÷28°CDB
RAV-SM304ATP-E
522
690
400x300x150
8
200
100
500
500
65
5-40 / 10-90
15°CWB÷24°CWB
5°CDB÷28°CDB
RAV-SM404ATP-E
RAV-SP404TP-E
720
1.080
400x300x150
8
200
100
500
500
65
5-40 / 10-90
15°CWB÷24°CWB
5°CDB÷28°CDB
RAV-SM564ATP-E
RAV-SP564ATP-E
1.060
1.580
400x300x150
8
200
100
500
500
65
5-40 / 10-90
15°CWB÷24°CWB
5°CDB÷28°CDB
RAV-SM804ATP-E
RAV-SP804ATP-E
1.280
1.920
400x300x150
8
200
100
500
500
65
5-40 / 10-90
15°CWB÷24°CWB
5°CDB÷28°CDB
RAV-SM1104ATP-E
RAV-SP1104AT-E
RAV-SP1104AT8-E
1.680
2.520
400x300x150
8
200
100
500
500
65
5-40 / 10-90
15°CWB÷24°CWB
5°CDB÷28°CDB
RAV-SM1104ATP-E
RAV-SP1104AT-E
RAV-SP1104AT8-E
2.080
3.360
400x300x150
8
200
100
500
500
65
5-40 / 10-90
15°CWB÷24°CWB
5°CDB÷28°CDB
RAV-SM1603AT-E
RAV-SP1604AT8-E
2.880
4.320
400x300x150
8
200
100
500
500
65
5-40 / 10-90
15°CWB÷24°CWB
5°CDB÷28°CDB
RAV-SM2224AT8-E
3.360
5.040
400x300x150
8
200
100
500
500
65
5-40 / 10-90
15°CWB÷24°CWB
5°CDB÷28°CDB
RAV-SM2804AT8-E
DXC031 DXC031 DXC031 DXC031 DXC031 DXC031 DXC031 DXC031
Minimum Air Flow rate
Maximum Air Flow rate
Dimensions (HxWxD)
Weight
Cable Max Length (Analogue Input) (Screened cable: 0.5 ~ 1.0 mm2)
Cable Max Length (Digital Input) (Non screened cable: 1.5 ~ 2.5 mm2)
Cable Max Length (Digital Output) (Non screened cable: 1.5 ~ 2.5 mm2)
Cable Max Length (TCC Link) (Non screened cable: 0.5 mm2)
Standard Rating
Operating temperature/humidity
Operating range - Cooling coil "Air on" temp
Operating range - Heating coil "Air on" temp
Outdoor Unit
Power supply Supplied from Outdoor unit
Air curtains are designed to be positioned above an entrance, providing a thermal curtain, which separates the outdoor and indoor environments. This historically has been produced by electrical heaters, however it is now possible to use a Toshiba heat pump system, with the added benefit of improved energy savings.
The air is accelerated and forced through a narrow discharge along the length of the air curtain creating a laminar air flow.
ENERGY SAVINGS► Stop drafts and reduces infiltration of outdoor air into the heated or air-conditioned area► EC motors compliant with ERP lot 11
COMFORT► By preventing the conditioned air to leave the building, or be affected by incoming air from the outside, the comfort levels inside the building are maintained, making it a more pleasant area for staff members and customers alike
FUNCTIONALITY► Provides a pleasant entrance to customers, whilst ensuring undesirable smells, contaminants and small insects are kept outside of the conditioned space
ADAPTABILITY► Suitable for installation in the ceiling space above the door, only the inlet grille and discharge outlet will be visible► Available in door widths from 1m to 2,5m
8kW-16kW
CAPACITY
-20°C/+46°C
OPERATION
54
Air Curtain Free-Hanging unit (CH)
3,0
3,0
4,0
4,0
5,0
5,0
6,0
6,0
Model Code Heating Capacity kW Outdoor Sizing hp
8,0
8,0
11,2
11,2
14,0
14,0
16,0
16,0
Air flow rate m3/h
1.600
2.210
2.400
2.950
3.200
4.420
4.000
5.160
Power Input Fan only kW
0,35
0,53
0,53
0,70
0,70
1,05
0,88
1,23
Door Width mm
1.000
1.000
1.500
1.500
2.000
2.000
2.500
2.500
Max Door Height m
3,0
3,2
3,0
3,2
3,0
3,2
3,0
3,2
Unit Weight kg
48
51
77
80
101
107
132
138
Sound Pressure dBA
54
55
55
56
56
57
57
58
RAV-CT101CH-M
RAV-CT101CH-L
RAV-CT151CH-M
RAV-CT151CH-L
RAV-CT201CH-M
RAV-CT201CH-L
RAV-CT251CH-M
RAV-CT251CH-L
Air Curtain Cassette unit (UH)
3,0
3,0
4,0
4,0
5,0
5,0
6,0
6,0
Model Code Heating Capacity kW Outdoor Sizing hp
8,0
8,0
11,2
11,2
14,0
14,0
16,0
16,0
Air flow rate m3/h
1.600
2.210
2.400
2.950
3.200
4.420
4.000
5.160
Power Input Fan only kW
0,35
0,53
0,53
0,70
0,70
1,05
0,88
1,23
Door Width mm
1.000
1.000
1.500
1.500
2.000
2.000
2.500
2.500
Max Door Height m
3,0
3,2
3,0
3,2
3,0
3,2
3,0
3,2
Unit Weight kg
40
43
95
98
99
105
120
126
Sound Pressure dBA
54
55
55
56
56
57
57
58
RAV-CT101UH-M
RAV-CT101UH-L
RAV-CT151UH-M
RAV-CT151UH-L
RAV-CT201UH-M
RAV-CT201UH-L
RAV-CT251UH-M
RAV-CT251UH-L
Air Curtain Built-in unit (BH)
3,0
3,0
4,0
4,0
5,0
5,0
6,0
6,0
Model Code Heating Capacity kW Outdoor Sizing hp
8,0
8,0
11,2
11,2
14,0
14,0
16,0
16,0
Air flow rate m3/h
1.600
2.210
2.400
2.950
3.200
4.420
4.000
5.160
Power Input Fan only kW
0,35
0,53
0,53
0,70
0,70
1,05
0,88
1,23
Door Width mm
1.000
1.000
1.500
1.500
2.000
2.000
2.500
2.500
Max Door Height m
3,0
3,2
3,0
3,2
3,0
3,2
3,0
3,2
Unit Weight kg
71
74
105
108
129
135
170
176
Sound Pressure dBA
54
55
55
56
56
57
57
58
RAV-CT101BH-M
RAV-CT101BH-L
RAV-CT151BH-M
RAV-CT151BH-L
RAV-CT201BH-M
RAV-CT201BH-L
RAV-CT251BH-M
RAV-CT251BH-L
Outdoor units combination Model Code (CH / UH / BH) Door Width (mm)
1.000
1.000
1.500
1.500
2.000
2.000
2.500
2.500
Max Door Height (m)
3,2
3,0
3,2
3,0
3,2
3,0
3,2
3,0
DI3 - Single phase
-
-
-
-
-
-
RAV-SM1603AT-E1
RAV-SM1603AT-E1
SDI- Single phase
RAV-SP804AT-E
RAV-SP804AT-E
RAV-SP1104AT-E
RAV-SP1104AT-E
RAV-SP1404AT-E
RAV-SP1404AT-E
RAV-SP1604AT-E
RAV-SP1604AT-E
DI4- Single phase
RAV-SM804ATP-E
RAV-SM804ATP-E
RAV-SM1104ATP-E
RAV-SM1104ATP-E
RAV-SM1404ATP-E
RAV-SM1404ATP-E
-
-
SDI - Three phases
-
-
RAV-SP1104AT8-E1
RAV-SP1104AT8-E1
RAV-SP1404AT8-E1
RAV-SP1404AT8-E1
RAV-SP1604AT8-E1
RAV-SP1604AT8-E1
RAV-CT101**-L
RAV-CT101**-M
RAV-CT151**-L
RAV-CT151**-M
RAV-CT201**-L
RAV-CT201**-M
RAV-CT251**-L
RAV-CT251**-M
55
RAV-CT AIR CURTAINS
56
NOTES
The manufacturer reserves the right to change the product specifications, data and images without previous notice. ΑΗΙ CARRIER S.E. EUROPE SINGLE MEMBER S.A. is not responsible for printing mistakes.
2020-2021 AHI CARRIER S.E. EUROPE SINGLE MEMBER S.A., all rights reserved.
AHI CARRIER SOUTH EASTERN EUROPE AIR CONDITIONING SINGLE MEMBER S.A.
HEADQUARTERS18, Kifissou Ave. 104 42 - Athens, Tel.: +30 210 6796300, Fax: +30 210 6796390, www.toshiba-aircon.grTHESSALONIKI BRANCH5, Ag. Georgiou Str., Cosmos Offices, 570 01 - Patriarhiko Pileas, Thessaloniki, Tel.: +30 231 3080430, Fax: +30 231 3080435AHI CARRIER HVAC BULGARIA EOODTrade Center Europe, Building 6, floor 3, office 6, 7 Iskarsko Shose Blvd. Sofia, 1520 - BULGARIA, Tel.: +35 929483960 Fax: +35 929483990, www.toshiba-aircon.bgAHI CARRIER ROMANIA SRL270d Turnu Magurele Str., Sector 4, Cavar center, Bucharest - ROMANIA, Tel.: +40 214 050751, Fax: + 40 214 050753, www.toshiba-hvac.ro