xs- ,+++ i automatedhematologyanalyzer · physician reports that are easy-to-read with numeric and...

8
XS-i Automated Hematology Analyzer Small Footprint. Big Difference.

Upload: hoangnhi

Post on 21-Sep-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

XS-1000i ™

Automated Hematology Analyzer

Small Footprint. Big Difference.

MKT-10-1139:MKT-10-1139 7/12/11 12:58 PM Page 1

Small But Powerful: The XS-1000i

Today’s Laboratory Challenges

Laboratories have continued to face a number ofchallenges for several years. These include clinical,operational and financial issues such as:

• Demand for clinically relevant information• Medical technologist labor shortage• Increased workload• Need for faster turnaround time• Requirement for high reliability• Limited laboratory budgets

1

Even with these challenges, the need for hematologytesting has remained steady or continues to grow.Laboratories are searching for hematology analyzersthat can improve productivity and efficiency whileproviding enhanced clinical information. Designedto be reliable and efficient, the Sysmex XS-1000ioffers laboratories an automated hematology systemthat can truly meet and exceed their expectations.The XS-1000i streamlines your workflow by providingtesting for up to 60 samples per hour, enabling rapidturnaround time.

XS-1000i without Auto Sampler

Proven Technology

The proven technologies – Fluorescent Flow Cytometry,Hydrodynamic Focusing and Non-cyanide Hemoglobin –of the XE and XT-Series have been incorporated into theXS-1000i Automated Hematology Analyzer.

Leading-edge hematology diagnostics requiringonly four feet of counter space:

• Effective diagnostic capabilities utilizingfluorescent flow cytometry

• CBC with 5-part differential• Simplicity in operation for streamlined workflow• Standardization across Sysmex platforms• Proven reliability as a member of the

X-Series of products

MKT-10-1139:MKT-10-1139 7/12/11 12:58 PM Page 2

Improved Clinically Relevant Resultswith XS-Series Technology

Rapid Results

The XS-1000i provides rapid, reliabletest results from just 20µL of samplefor assistance in patient diagnosisand therapeutic monitoring. It utilizesthe same diagnostic power andaccuracy as the X-Series of high volumeanalyzers with comparable results.

Now you can spend less timemanaging equipment and samplehandling and more time on the criticalanalytical work in your laboratory.

2

Laser Technology

RBC and PLT Counting

WBC DIFF Detection

Fluorescent Flow CytometryYields Optimized Productivity

The Sysmex XS-1000i AutomatedHematology System utilizes thepower of fluorescent flow cytometry(FFC) and hydrodynamic focusingtechnologies. Using a unique,stable, avalanche photodiode witha laser bench, Sysmex fluorescentflow cytometry provides the sensitivityneeded for measuring and differentiatingcell types in whole blood.

Hydrodynamic Focusing(DC Detection)

Fluorescent technology andhydrodynamic focusing enablethe analyzers to consistently classifynormal WBC (white blood cell),RBC (red blood cell), and PLT(platelet) populations from abnormalpopulations, thereby decreasing thenumber of manual interventions.

A.C.A.S. WBC Differential Counting

MKT-10-1139:MKT-10-1139 7/12/11 12:58 PM Page 3

AdvancedParameters InOneComprehensiveSystem

3

RBCs and PLTs

RBCs and PLTs are counted in adedicated channel using Impedanceor Direct Current (DC) detectionmethod combined with hydrodynamicfocusing technology. Challenges tocell counting such as coincidence orrecirculation are circumvented andautomatic discriminators separatethe two cell populations.

Even with samples at extremelylow or unusually high concentrations,the Sysmex system analyzes RBCsand PLTs with uncompromisedprecision and accuracy.

High Quality Hemoglobin(HGB) Analysis

The XS-1000i utilizes the non-cyanidereagent, Sodium Laurel SulfateHemoglobin (SLS). The end productis a colored compound that ismeasured spectrophotometrically.Since hemoglobin determinations areperformed from a dilution and in itsown separate chamber, there is nointerference from high WBC counts,lipemia or abnormal proteins.

Direct Hematocrit(HCT) Measurement

The cumulative pulse heights of allthe RBC counts yield the HCT. This isbased on the principle that the pulseheight (voltage change) produced bycells passing through the aperture isproportional to cell volume.

Non-cyanide Hemoglobin

Adaptive Cluster Analysis System (ACAS)

WBC Differential Scattergram

WBC a Clear Differentiation

The combination of side scatter(cell complexity), forward scatter(size) of nucleated cells provides aconcise and precise image of eachdetected peripheral blood cell.

This 3-dimensional blood cell analysisprovides unique accuracy and precision.Fluorescence labeling of peripheralblood cells is a milestone for theroutine leukocyte differential.

Fluorescent technology enablesthe XS-1000i to reliably differentiatenormal WBC populations fromabnormal WBC populations. Thesensitivity of the unique applicationof fluorescent flow cytometry givesthe lab a high level of confidence inreporting accurate WBC differentials,even on critical patient samples whenthe WBC count is low.

MKT-10-1139:MKT-10-1139 7/12/11 12:58 PM Page 4

Big Benefits For Small Labs

4

Save Time and Become More Productive with the XS-1000i

Enhanced productivity witheasy-to-use Windows® XPOperating System

Operation is streamlined withreagent monitoring informationdisplayed for the operatorand operational alerts whenreagents run low.

The XS-1000i providescustomized reporting formats

so you can produce comprehensivephysician reports that are

easy-to-read with numericand visual depictions.

Reliable Performance

• > 1000 XS-1000i analyzers installedin North America

• SNCS, remote monitoring, to providemaximum uptime

• Technical support available24-hours / day

• Ranked by independent third partyas highest vendor for reliability for11 consecutive years*

*2010 IMV ServiceTrak

Reportable, DiagnosticInformation from a SingleSample Analysis

• Fluorescent flow cytometry forWBC count and differential

• 5-part whole blood WBCand differential (NEUT + LYMPH +MONO + EO + BASO)

• Hydrodynamic focused flowcell counting for RBC and PLT

• Low sample volume requirements;minimum 20µL whole blood

Streamlined Workflow

• True walk-away analytical processwith closed tube auto sampling

• Push button, walk-awaydaily maintenance

• Standardization with other Sysmexsolutions for multi-hospital sites

• Can be used in conjunction withSysmex WAM™ Decision SupportSoftware for the Clinical Laboratory

Easy-to-use

• Intuitive software menus• Barcoded reagent management• Comprehensive quality control

information• On-board help key for

rapid troubleshooting

The XS-1000i improves workflowby providing diagnostic alerts

including a message on the screenidentifying when patient samples are

identified as Negative or Positive.

MKT-10-1139:MKT-10-1139 7/12/11 12:58 PM Page 5

Peak Performance

5

e-Tools: Assuring Qualityand Optimizing Performance

SNCSTM, Sysmex NetworkCommunications System, is proprietarysoftware which enables fast, securecommunication from your analyzer toSysmex servers using a high-speed,outbound internet connection. Thispowerful tool is the instrument datalink feeding a variety of innovativetools and services.

InsightTM

Insight is a web-based InterlaboratoryQuality Assessment Program (IQAP)that allows on-demand quality controlreporting with access anytime, anywhere.Meet requirements to document peercomparison data for your analyzerwhile eliminating manual steps.

Remote Monitoring

Continuous collection andmonitoring of instrument performancedata is linked to our tracking anddispatch system. We monitor yourinstrument performance, instrumentconfiguration settings and back-upsettings continuously.

Make your lab more efficient with:

• Unobtrusive, remote andreal-time monitoring

• Proactive identification andfollow-up of potential issues

• Enhanced first-time field fixes,if needed

e-Supply - Reagent InventoryManagement

The e-Supply program offers onlinereagent monitoring that simplifies bothordering and inventory processes. Thisinnovative program helps you:• Track reagent usage and inventory• Maintain appropriate inventory levels• Reduce your shipping cost

MKT-10-1139:MKT-10-1139 7/12/11 12:58 PM Page 6

Principles & Technologies Fluorescent Flow Cytometry:WBC-Diff

Direct Current – Sheath Flow:RBC, HCT, PLT

Non-cyanide, Sodium Lauryl Sulfate (SLS):HGB

21 Whole Blood Reportable Parameters WBC, RBC, HGB, HCT, MCV, MCH, MCHC,PLT, NEUT%, LYMPH%, MONO%, EO%,BASO%, NEUT#, LYMPH#, MONO#, EO#,BASO#, RDW-SD, RDW-CV, MPV

Linearity WBC: 0 – 400.00 x 103/µLRBC: 0 – 8.00 x 106/µLHBG: 0 – 25.00 g/dLHCT: 0 – 60%PLT: 0 – 5,000 x 103/µL

Throughput Single Sample Mode: 60 samples/hourAuto Sampler Mode: 53 samples/hour

Sample Volumes Closed mode: 20µLCapillary mode; Pre-dilute: 67µL (1:7 dilution)

Data Storage 10,000 samples including histograms(IPU: Information Processing Unit)

Quality Control Common Quality Control material to(Total QC Management) XE and XT-Series

Comprehensive QC filesLevey-Jennings Control ChartsX-barM fileOnline Quality Assurance Program

Interfaces ASTMSysmex WAM™ (HL7 & ASTM)

Dimensions/Weight Main Unit:w x h x d [in] / [lbs] 12.6" x 15.9" x 16.3" / 52.8 lbs.

With Auto Sampler:16.7" x 15.9" x 24.2" / 74.8 lbs.

Models XS-1000iXS-1000i with Auto Sampler (XS-AL)

SysmexXS-1000i Specifications

MKT-10-1139:MKT-10-1139 7/12/11 12:58 PM Page 7

Sysmex Corporation

www.sysmex.co.jp

Sysmex America, Inc.One Nelson C. White Pkwy,

www.sysmex.com/usa

Sysmex Canada, Inc.

www.sysmex.ca

Sysmex do Brasil Indústria e Comércio Ltda

São José dos Pinhais

www.sysmex.com/br

© 2011 Sysmex America Inc. All rights reserved.Document Number MKT-10-1139 07/2011

MKT-10-1139:MKT-10-1139 7/12/11 12:58 PM Page 8