XAS 400 JD7 iT4 Compressor
Committed tosustainable productivity
Scott Malm
2
Air/Oil System Overview - XAS 400 JD iT4
Regulating valve
Spring loaded
Adjusting receiver pressureby changing spring tension
Pressure gauge
to speed regulatorto unloading valve
Regulating pressure
Receiver pressure
to blow-down valve
Regulating Valve Service Kit – 2911 0111 00
12
Unloading Valve or Air System Inlet Valve
Spring loaded in the open position
Control Air closes the inlet
Also serves as check valve
LegendReceiver PressureFrom Pressure Regulator right now very low to zero pressure
Unloading valve service kit – 2911 0074 00
15
Maintains a minimum pressure
of 58-60 PSI for oil flow
Also contains the final check
valve
AIR SYSTEM MIN PRESS VALVE
Oil System
Oil Separator
Classic Reasons For Oil Carryover– Over filled receiver– Plugged scavenge line– Wrong type of oil (no anti foam agent)– Scavenge tube installed improperly– Being used improperly for application (Sandblasting)
Separator Element Service Kit – 2911 0075 00
Control System
25
Control Panel – XC2002 Controller
Stop Button
XC2002 Menus
28
Unit Type 15 For XAS 400 JD iT4Software Level 1.70.0 for XAS 400 JD iT4
XC2002 AlarmsIf an Alarm occurs, a pop-up window will display for as long as the alarm is active, in any view. The flashing red Alarm LED will keep flashing.
The Alarm will be shown with the phrase “Unack”. Push the Enter button to acknowledge the alarm. Once the alarm is acknowledged if it is still active then the red LED in the triangle will stay on solid.
An Alarm should always be acknowledged before solving the cause of the Alarm.
The Alarm display can be left by pushing the Back button.
If more than one Alarm occurs, the Up and Down arrows may be used to scroll through the list. Newest Alarms will be at the bottom of the list.
If a Shutdown occurs, the Shutdown alarm code will be shown.
32
34
Engine Faults
Electrical System
36
Wiring Diagram
37
Legend – Wiring Diagram
38
Wiring Diagram - Engine
39
40
Wiring Diagram – Legend - Engine
Maintenance
41
Maintenance – XA(T,V)S 400 JD IT4
Daily:
Check engine oil level
Check compressor oil level
Check coolant level
Drain water from fuel filter
Empty air filter vacuator valve
Check tire pressure
Maintenance – XA(T,V)S 400 JD IT4
Initial Service at 50 Hours
Check electrolyte level and terminals of battery
Check for leaks in Air, Oil, and Fuel systems
Check wheel nut torque (if equipped)
Check and adjust brakes
Check and adjust fan belts
Replace compressor oil filter
43
Maintenance – XA(T,V)S 400 JD IT4500 Hour service pack part number 1310 3004 47
Perform 50 hour service tasks
Clean oil cooler, radiator, intercooler
Lubricate door hinges
Grease towing eye shaft or ball coupling and shaft
Analyze coolant
Replace/Check air filter elements
Replace engine oil and filter
Replace fuel filters
44
Maintenance – XA(T,V)S 400 JD IT41000 Hour service pack part number 1310 3004 48
Perform 500 hour service tasks
Test safety valve and shut down switches
Check all compressor Oil/Air hoses
Replace separator element
Replace compressor oil and spin on filter
Replace blow down valve on unloader Assy.
Clean flow restrictor in oil scavenge line
45
IT4 EXHAUST AFTERTREATMENT
46
IT4 Exhaust Aftertreatment
1. Diesel Particulate Filter (DPF)
2. Diesel Oxidation Catalyst (DOC)
47
XC2002 DPF Status Indicators
48
Stationary DPF Regeneration
Atlas Copco recommends that the DPF configuration be left in the AUTO mode at all times; however, in the event that a stationary or manual regeneration is desired, the following process should be followed.
Go to the “STATION REGEN” screen. For normal operation this should be “OFF”.
Press the “Enter” button. This function is not password protected.
Use the up/down arrow to change the selection to “ON” and press the “Enter” button.
Go to the “DPF” screen. For normal operation this should be in “AUTO” mode.
Press the “ENTER” button.
This is password protected. Enter “1968”
Use the up/down arrow to change the selection to “ON” and press the “Enter” button.
This will set the unit up for manual regeneration; after a few moments, the regeneration icon should appear, confirming the unit is regenerating.
After completion, Set both STATION REGEN to “OFF” and DPF to unit to “AUTO” mode.
49