x rays brochure

2
Model PXP-20HF PXP-20HF plus PXP-40HF PXP-60HF Output Tube vol./current 90kV/20mA 100 kV / 20 mA 100 kV / 35 mA 100 kV / 60 mA Voltage range 40-90 kV, 1 kV step 40 -100 kV, 1 kV step 40 -100 kV, 1 kV step 50 -100 kV, 1 kV step mAs range 0.3 mAs-50 mAs, 22 steps 0.3 mAs-50 mAs, 22 steps 0.4 mAs-100 mAs, 25 steps 0.4 mAs-100 mAs, 31 steps Max. output 1.6 kW@80 kV 1.8 kW@80 kV 2.4 kW@80 kV 3.2 kW@80 kV X-ray tube Application Toshiba D-124 Toshiba D-124 Toshiba D-124 Toshiba D-205 Focal spot 1.2 mm 1.2 mm 1.2 mm 2.0 mm Collimator Min. light field 5 cm x 5 cm@1 m SID 5 cm x 5 cm@1 m SID 5 cm x 5 cm@1 m SID 5 cm x 5 cm@1 m SID Max. light field 35 cm x 35 cm@65 cm SID 35 cm x 35 cm@65 cm SID 35 cm x 35 cm@65 cm SID 35 cm x 35 cm@65 cm SID Lamp 50 Watt halogen lamp 50 Watt halogen lamp 150 Watt halogen lamp 150 Watt halogen lamp 30 sec 30 sec 30 sec 30 sec Auto timer 2m 2m 2m 2m SID scale length Built-in with laser beam Built-in with laser beam Built-in with laser beam Built-in with laser beam Laser poiner 110 / 220 V AC 110 / 220 V AC 110 / 220 V AC 220 V AC Power Input 50 / 60 Hz, single phase 50 / 60 Hz, single phase 50 / 60 Hz, single phase 50 / 60 Hz, single phase Frequency / phase ±10% ±10% ±10% ±10% Voltage compensation 7-segment LED read-out reversible, Hand switch remote control function Special features 4 APR 4 APR 8 APR 8 APR Light weight (8.6 kg) Light weight (9 kg) Light weight (12 kg) Light weight (13kg) PXP-20HF / PXP-20HF plus PXP-40HF / PXP-60HF Specifications Medical Econet GmbH Mainstraße 6 c-d D-45768 Marl Telefon +49 (0) 23 65 / 9 24 37-0 Telefax +49 (0) 23 65 / 9 24 37-55 [email protected] www.medical-econet.com Portable X-ray Units

Upload: instrulife-oostkamp

Post on 12-Nov-2014

659 views

Category:

Documents


3 download

DESCRIPTION

X-ray [email protected]

TRANSCRIPT

Page 1: X Rays Brochure

Model PXP-20HF PXP-20HF plus PXP-40HF PXP-60HF

Output Tube vol. /current 90 kV/20 mA 100 kV/20 mA 100 kV/35 mA 100 kV/60 mA

Voltage range 40-90 kV, 1 kV step 40-100 kV, 1 kV step 40-100 kV, 1 kV step 50-100 kV, 1 kV step

mAs range 0.3mAs-50mAs, 22 steps 0.3mAs-50mAs, 22 steps 0.4mAs-100mAs, 25 steps 0.4mAs-100mAs, 31 steps

Max. output 1.6 kW@80 kV 1.8 kW@80 kV 2.4 kW@80 kV 3.2 kW@80 kV

X-ray tube Application Toshiba D-124 Toshiba D-124 Toshiba D-124 Toshiba D-205

Focal spot 1.2 mm 1.2 mm 1.2 mm 2.0 mm

Collimator Min. light field 5cm x 5 cm@1m SID 5cm x 5 cm@1m SID 5cm x 5 cm@1m SID 5cm x 5 cm@1m SID

Max. light field 35cm x 35cm@65cm SID 35cm x 35cm@65cm SID 35cm x 35cm@65cm SID 35cm x 35cm@65cm SID

Lamp 50 Watt halogen lamp 50 Watt halogen lamp 150 Watt halogen lamp 150 Watt halogen lamp

30 sec 30 sec 30 sec 30 sec

Auto timer 2 m 2 m 2 m 2 m

SID scale length Built-in with laser beam Built-in with laser beam Built-in with laser beam Built-in with laser beam

Laser poiner 110/220 V AC 110/220 V AC 110/220 V AC 220 V AC

Power Input 50/60 Hz, single phase 50/60 Hz, single phase 50/60 Hz, single phase 50/60 Hz, single phase

Frequency /phase ± 10 % ± 10 % ± 10 % ± 10 %

Voltage compensation 7-segment LED read-out reversible, Hand switch remote control function

Special features 4 APR 4 APR 8 APR 8 APR

Light weight (8.6 kg) Light weight (9 kg) Light weight (12 kg) Light weight (13kg)

PXP-20HF / PXP-20HF plusPXP-40HF / PXP-60HF

Specifications

Medical Econet GmbHMainstraße 6 c-dD-45768 MarlTelefon +49 (0) 23 65/ 9 24 37-0Telefax +49 (0) 23 65/ 9 24 [email protected]

Portable X-ray Units

Page 2: X Rays Brochure

Features■ Economic price for medical practitioners

■ Ultra light weight & compact size

■ Constant X-ray output without influence

of line power fluctuation

■ Equipped new remote control functions

■ Flat touch panel & digital display

■ LED readout / Display reverse switch

■ Scale tape for SID measurement

■ Built-in halogen collimator and laser pointer

■ Power requirement : 110 / 220 VAC, 50 / 60 Hz

■ Standard Accessories : Power cord cable, Exposure

hand switch, Metal carrying case and Manual

• X-ray output : 20 mA / 90 kVp

• Generator : 70 kHz, HF Inverter Type

• kV Range : 40-90 kV / 1 kV Step

• mAs Range : 0.3 to 50 mAs

• Light weight : 8.6 kg and compact size

• PROM memories for 4 selections

PXP-20HF

• X-ray output : 20 mA / 100 kVp

• Generator : 70 kHz, HF Inverter Type

• kV Range : 40-100 kV / 1 kV Step

• mAs Range : 0.3 to 50 mAs

• Light weight : 9.0 kg and compact size

• PROM memories for 4 selections

PXP-20HF plus

• X-ray output : 35 mA / 100 kVp

• Generator : 70 kHz, HF Inverter Type

• kV Range : 40-100 kV / 1 kV Step

• mAs Range : 0.4 to 100 mAs

• Light weight : 12 kg

• High power : 2.4 kW

• PROM memories for 8 selections

PXP-40HF

• X-ray output : 60 mA / 100 kVp

• Generator : 70 kHz, HF Inverter Type

• kV Range : 50-100 kV / 1 kV Step

• mAs Range : 0.4 to 100 mAs

• Light weight : 13 kg

• High power : 3.2 kW

• PROM memories for 8 selections

PXP-60HF

Remote controlHand switch and softwareThis exclusive software on our portable X-ray units allows total control of all your custom technique

values. PROM memory pre-sets, collimator light / laser pointer and exposure control functions right

from your hand switch.

This allows you to make adjustments on the fly without placing your unit on the ground or fumbling

for awkward dials and display panel controls. This feature is standard on all our portable units.