www.inels.com presentation inels. characteristics i: inels ® is a smart wiring system designed...
TRANSCRIPT
www.iNELS.com
PRESENTATIONiNELS
CHARACTERISTICS
• iNELS® is a smart wiring system designed especially for:
• switching
• dimming
• control and measurement
• monitored state of object
• integration of multimedia
• installation bus CIB: communication and power supply units
• actors (receivers) and sensors (transmitters) and data telegrams
• IDM software-assigned functions and operating parameters
www.iNELS.com
Presentation iNELS
SYSTEM OPTIONS OF iNELS
• switching and dimming of lighting
• Detection of indoor and outdoor movement and light intensity
• motion control blinds, shutters, awnings, garage,
doors, entrance gates etc.
• management systems, heating and air conditioning
• control various appliances (with interlocks on selected priorities)
• integrated electronic security alarm
• visualization - IDM, iMM
• Remote Access (GSM and Internet)
www.iNELS.com
Presentation iNELS
THE POSSIBILITY APPLICATION OF iNELS
• Houses (lighting, heating, air conditioning, ventilation,
blinds, etc.)
www.iNELS.com
Presentation iNELS
THE POSSIBILITY APPLICATION OF iNELS
• Apartment buildings (plus common area management)
www.iNELS.com
Presentation iNELS
THE POSSIBILITY APPLICATION OF iNELS
• Cottages (plus remote access)
www.iNELS.com
Presentation iNELS
THE POSSIBILITY APPLICATION OF iNELS
• Hotels and restaurants (the central feature scenes)
www.iNELS.com
Presentation iNELS
INSTALLATION BUS CIB
• communication protocol is an internal (company)
• response time of the entry into a central unit to output up to 150 ms
• free topology:
• Linear
• and their combinations
• Star
• Tree
Linear
StarTree
www.iNELS.com
Presentation iNELS
PARAMETERS INSTALLATION BUS CIB
• 1A maximum load for each branch
of the CIB
• total length of one branch (line) CIB may
be 550 m
• CU2-01M - 2 separate branches directly to CIB
- 4 more branches CIB via external masters
• on each branch 32 HW addresses,
is 32 units iNELS
• CP-1000 - 2 separate branches directly to CIB
- 8 more branches CIB via external masters
www.iNELS.com
Presentation iNELS
PARAMETERS INSTALLATION BUS CIB
1 CIB branch:
The physical limit 1A
Logical limit 32 address
Length 550m
Total:
Number of iNELS units CU2-01M 192
CP-1000 320
www.iNELS.com
Presentation iNELS
SYSTEM BUS TCL2
• System with linear bus topology
• Connecting external master module MI2-02M, which allow
increasing the number of branches (lines) installation bus CIB
• Maximum length of TCL2 bus is 300 m
• Recommended cable J-Y(St)-Y 2x2x0.8
• Ends with a resistance with value 120 Ω
www.iNELS.com
Presentation iNELS
SUMMARY -
• Accumulation of bus lines with power lead :
• We recommend to avoid accumulation the power lead. Alternatively, a
minimum distance from power lines 30 cm
• Conditions for bus line :
• Recommended cables
• Electromagnetic interference is avoided
• Cable at any point is mechanically damaged
• Cable must not be mechanically stressed (must be
respected technology installation procedures, temperature, bend
radius, modes of attachment)
GENERAL PRINCIPLES FOR THE MANAGEMENT BUS
www.iNELS.com
Presentation iNELS
DESIGN OF SYSTEM ELEMENTS
• Modul „M“ - Installation on DIN railM
DI/AC TI/AI
DO AO
• Box „B“ - installation into a wiring boxB
DI/AC TI
DO AO
• Wall drivers E/G
DI TI
DO
www.iNELS.com
Presentation iNELS
Central Unit CU2-01M
Ethernet10/100base
27
.2 V
DC
CIB
1
CIB
2
TC
L2
RS
23
2
PS
M
4x
DI
1x
DO
• Ethernet 10/100 Mbit/s• power 27.2V DC, 24V DC• 2x interfaces CIB• 1x interfaces TCL2• 1x serial chanel RS-232• 2x PSM• 4x DI (IN1 - IN4)• 1x DO• integrated WEB server
• SW IDM, SCADA/HMI Reliance, • OPC server
www.iNELS.com
Presentation iNELS
External Master CIB MI2-02M
• 2 branch of CIB bus more
(identifying, addressing and
configuration of units), data processing
and transfer them to CU2-01M
• 1x TCL2
• Circle switch is used for setting the
address of MI2-02M on the
TCL2 bus
• LEDs for identification
communication on the CIB bus
TC
L2
CIB
CIB
Circle switch
LED diod
www.iNELS.com
Presentation iNELS
GSM Gate - GSM2-01
• 32 phones numbers
• 48 outgoing SMS each on a 20-digit
• 32 incoming SMS each on a 20-
digit• defined dialing phone numbers and
ringing for 20 sec and end
• You can define actions
on incoming calls
27
.2 V
DC
RS
23
2R
MS
A
www.iNELS.com
Presentation iNELS
Bus separator for power supply BPS2-02M
• ensures the correct power of two branches
(lines) CIB, separates power supply
units from peripheral and
communication master
• terminals for connection 27.2VDC
source AKU terminals for
connecting back- up battery
• 2x CIB interfaces
AK
U
27
.2 V
DC
27
.2 V
DC
2x
CIB
• terminals +27 V and GND for power
supply and CU2-01-01 GSM2
www.iNELS.com
Presentation iNELS
Connections of BPS2-02M A CU2-02M www.iNELS.com
Presentation iNELS
Connections of BPS2-02M A MI2-02M www.iNELS.com
Presentation iNELS
Binary input - IM2-20B, IM2-40B, IM2-80B, IM2-140M
• 2x, 4x, 8x a 14x DI balancing option for alarm
CIB
CIB
12
VD
C
12
VD
C
2x
DI
4x
DI
1x
TI
1x
TI
CIB
12
VD
C
8x
DI
1x
TI
• contact inputs can be defined as NC / NO
• output 12V DC / 75 mA (150 mA) for power of alarm
units
CIB
12
VD
C
14
x D
I
14
x D
I
www.iNELS.com
Presentation iNELS
Temperature input - TI2-40B, Analog input ADC2-40M
• 4x TI -
connection resistance
temperature sensors
TC/TZ
CIB
4x
TI
4x
TI
CIB
CIB
3x
AI
1x
AI
• 4x AI the common terminal
GND
• input - U, I a RTD
• selectable ranges
• A / D converter resolution 14 bit
• For powering passive
resistive sensor termin
al with a
reference
voltage 5.4V• only in version IDM 1.1.3.576
www.iNELS.com
Presentation iNELS
Dimming actuator - LM2-11B
• switching and dimming load RLC
• autodetection of load
• 1x TI
• 1x a 2x DI (230V AC)
• 1x a 2x AO (250 VA)
CIB
CIB
1x
TI
1x
DI
1x
AO
www.iNELS.com
Presentation iNELS
Dimming actuator - DA2-22M
• switching and dimming load
RLC, LED, (ESL)
• 1x TI
• 1x a 2x DI (230V AC)
• 1x a 2x AO (500 VA)
CIB
CIB
1x
TI
2x
DI
2x
AO
• potential at terminal L on DA2-22M is
recommended to protect
the safety element
corresponding to the connected
load
(fuse characterized. F)
Setup load and minimum brightness with potentiometers on the front side.
www.iNELS.com
Presentation iNELS
Dimming actuator - DIM-6
• switching and dimming load RLC
• 1x AO (2000 VA)
• 1x AI (0-10 V, 1-10 V)
• modular expandable up to 10 000
VA
CIB
1x
AO
1x
AI
1x
DI
10
kW
• hw setup of load (jumper)
www.iNELS.com
Presentation iNELS
Dimming actuator - LBC2-02M
• control dimmable ballasts for
fluorescent tube
• 2x AO (1-10 V)
• 2x DO (RO) (16 A/4000 VA AC1)
CIB
CIB
2x
AO
1x
DO
1x
D
O
www.iNELS.com
Presentation iNELS
Switching actuator - SA2-01B, SA2-02B
• switching appliances and loads
• 2x DO (RO) -
floating switching contact
• Relay contact 16 A/4000 VA
AC1 - SA2-01B, 8 A/2000 VA
AC1
- SA2-02B
CIB
CIB
1x
TI
1x
DO
CIB
CIB
1x
TI
1x
DO
1x
DO
www.iNELS.com
Presentation iNELS
Shutters actuator - JA2-02B , JA2-02/DC
• motion control shutters,
blinds etc.• JA2-02B - 2x RO
• 4 A/1000 VA AC3
• JA2-02B/DC - 2x RO - drives
with supply voltage
of 24V DC, direction of
rotation is controlled by
changing the polarity
of the motor
CIB
1x
TI
L
DO
WN
UP
CIB
1x
TI
U ◄ ◄
www.iNELS.com
Presentation iNELS
Switching actuator - SA2-02M, SA2-04M
• switching appliances and
loads• 2x DO (RO) - SA2-02M -
floating switching contact
16 A/4000 VA AC1
CIB
CIB
1x
DO
1x
DO
CIB
CIB
1x
DO
1x
DO
1x
DO
1x
D
O• 4x DO (RO) - SA2-04M –
floating switching contact
16 A/4000 VA AC1
www.iNELS.com
Presentation iNELS
Switching actuator - SA2-012M
• switching appliances and
loads• 12x DO (RO) – switching contact
8 A/2000 VA AC1
• each of four identical outputs
switching the same
potential
CIB
4x
DO
4x
DO
23
0 V
AC
• power for unit is 230V AC
4x
DO
www.iNELS.com
Presentation iNELS
Analog output - DAC2-04B, DAC2-04M
• 4x AO - 0-10V, 1-10V
• control devices that are
controlled by this signal
(dimmable ballasts of
fluorescent lamps, dimmers,
thermoelectric valves,
servo
drives, instrumentation
element)
CIB
CIB
4x
AO
1x
TI
CIB
CIB
4x
AO
www.iNELS.com
Presentation iNELS
Thermovalve controler - HC2-01B/AC, HC2-01B/DC
• switching thermoelectric heads 0/1
• HC2-01B/AC –
1x DO - 24 - 230V AC
Maximum peak current
0.15 A/230V AC
• HC2-01B/DC –
1x DO - 24V DC
Maximum peak current
0.5 A/30V DC
1x AO - 0-10V
CIB
CIB
1x
TI
1x
DO
CIB
•C
IB
•1x
TI
1x
DO
•1
x A
O
www.iNELS.com
Presentation iNELS
Multifunction control unit - SOPHY2, SOPHY2-L
• sensor of the human voice
• ambient light intensity sensor
• 1x TI - integrated temperature sensor
• design in a LOGUS90
CIB
4x
DI
• IR receiver
• IR transmitter
• 6x DI
www.iNELS.com
Presentation iNELS
1x
DI
1x
DI
Wall Switch - WSB2-20, WSB2-40, WSB2-80
• integrated micro-switches with a
low stroke
• design:
CIB
CIB
• WSB2-20 - 2x DI, 2x DO
• WSB2-40 - 4x DI, 4x DO
• WSB2-80 - 8x DI, 8x DO
• 1x TI - integrated temperature sensor
• design in a LOGUS90
www.iNELS.com
Presentation iNELS
Termoregulator - IDRT2-01
• control temperature and heating circuit
• design in Logus90
• 1x TI
• 1x AI - correction in the range +/- 3°C
• 2x DO indicate LED
Ko
rek
ce
Sta
te
Mode
www.iNELS.com
Presentation iNELS
Touch screen - EST2, EST2/RGB
• 3,5“ touch screen
• It consists of 3 (4) iNELS elements :
IM2-140M, IDRT2,
KEY2-01, (ADC2-40M)
• design in a LOGUS90
• 2(3) main screen:
With configurable icons,
with digital controller for
temperature corection, (screen for
RGB control)
www.iNELS.com
Presentation iNELS
EST2 configurable icons
• Option 4-12 icons
• 48 different icons in librery
• Design in a LOGUS90
• Distinguishes between long and short
press configuration is setup via binary
inputs IM2-140M
www.iNELS.com
Presentation iNELS
EST2 termostat a RGB control www.iNELS.com
Presentation iNELS
EST2 connection for control RGB www.iNELS.com
Presentation iNELS
THANK YOUFOR YOURATTENTION
Martin ŠevelaProduct manager
www.iNELS.com
Presentation iNELS
P a l a c k e h o 4 9 3 | 7 6 9 0 1 Ho l e s o v, V s e t u l y | Cz e c h R e p u b l i c t e l . : + 4 2 0 5 7 3 5 1 4 2 2 1 | f a x : + 4 2 0 5 7 3 5 1 4 2 2 7 | e l k o@e l k o e p . c om | www. e l k o e p . c om