Using BIM Specifications forParametric Indexing, Search, and Web Services
Parametric design revolves around a basic knowledge of geometry and relationships between entities. These properties can then be altered, giving different outcomes of form.
Woobius Scribbles Bob Leung (architect), Daniel Tenner (technologist), And the Masked Architect
1Deborah MacPhersonSpecifications and Research, Cannon Design
Specs are a combination of UniFormat, MasterFormat, and OmniClass
2
A1010 Standard Foundations1 Performancea Basic Function:i Provide standard foundations as required to support the completed and occupied buildingsafely and without uncontrolled subsidence or other movement.ii Standard foundations comprise the following elements:• Spread footings below columns and piers.• Continuous footings below walls.• Foundation walls not a part of basements.• Caisson caps.iii Where standard foundations are integral with elements defined within another element group,meet requirements of both element groups.iv Provide frost protection for foundations in accordance with UFC 3-310-01.2 Productsa Do not use any of the following:i Wood foundation systems.ii Masonry footings.b Cast-in-Place concrete materials, installation, etc. shall be in accordance with UFGS specification03 31 00.00 10, Cast-in-Place Structural Concrete.
Whitby Mental Health Centre
UniFormat
3
PERFORMANCE REQUIREMENTS
Structural Performance Characteristics: As follows:
Provide gypsum board shaft-wall assemblies for horizontal duct enclosures capable of spanning distances indicated within the deflection limits indicated.
SUBMITTALS
Product Data: For each gypsum board shaft-wall assembly specified.Fire-Test-Response Reports: From a qualified independent testing and inspecting agency substantiating each gypsum board shaft-wall assembly’s required fire-resistance rating.
LEED Submittals:
Product Data for Credit MR 4.1: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Include statement indicating costs for each product having recycled content.
Documentation for for Credit MR5: Materials shall be extracted, harvested and manufactured regionally within a radius of 800 km (500 miles) of the project site. Provide documentation identifying the location of manufacture, extraction and harvest of materials provided under this section.
QUALITY ASSURANCE
Source Limitations: Obtain components for each gypsum board shaft-wall assembly indicated through one source from a single manufacturer.Fire-Resistance-Rated Assemblies: Provide gypsum board shaft-wall assemblies as follows:
Assemblies comply with requirements of fire-response-tested assemblies indicated by GA File Numbers in GA-600, “Fire Resistance Design Manual”; or design designations in UL’s “Fire Resistance Directory” or certification listings of Warnock Hersey or another testing and inspecting agency acceptable to authorities having jurisdiction.
MasterFormat
4
OmniClass
11-17 11/11-17 24 Office and Retail Facilities
11-17 11 11 An office building which is headquarters for an organization
21-51 51 00+13-15 11 34 11 Climate control system (HVAC) Products for office spaces
13-15 11 34 11<11-13 24 11An office space which is part of a hospital
5
21-51 51 00+13-15 11 34 11> 11-13 24 11
Capital Construction Consultants Inc link
GSA Format EstimateReport, Any New K-12School, by Kisent link
6
Data about the same things can be reported different ways
Normalization of Facility, Space, and Product Type Namespaces
Lab is-aLaboratory
Brick Is-part-ofExterior EnclosureLoad Bearing Wall
Hospital isUse Group I-2
Site is in XYZ Jurisdiction. Design Criteria Are: Wind Speed 85 mph (3 second gust) Wind Exposure Site
'Swoosh' pavilion swoops into viewArchitectural Association, London link
Kort for hovedet link
7
Attributes and Properties
Simplifying the Creation of Revit Families by Nesting AECbytes link
8
Connecting Attributes and Properties
Simplifying the Creation of Revit Families by Nesting AECbytes link
9
Mapping between Standards and Formats
pha
ses.
Figure 3. Mapping GERA Lifecycle and TOGAF ADM PhasesAnalyzing The Open Group Architecture Framework from the GERAM
PerspectivePallab Saha [link]
Construction Operations Building Information Exchange (COBIE) Workflow
Onuma Planning System [link]
10
Role of Metadata
80 4-point near-alignments of 137 random points linkMedical Asset Metadata Standard, Health Education Assets Library (HEAL) link
11
Role of Ontology
BOUN MultiAgentSystems Research Group Link
Stanford Interoperability and Supply ChainTest Case: Mapping Between OmniClass and IfcXML Link
12
Avoiding Markup Disasters
Snow.com
niklas elmqvist | phd thesis3D Occlusion Management and Causality Visualization link
Rise Interactive, Keyword Builder link
13
BIM specifications
SustainableDesignEmergency
ShapeRepresentation
Manufacturers
Libraries
Publishers
StandardsDevelopment
Building Codes
OpenGeospatial
Variety of Stakeholder Needs
14
Questions? Comments? Please contact:
Deborah [email protected] 907 2353
15Conformal Mapping 1/(z*z) by fdecomite [link]