wpl 15 acs...product data sheet type wpl 25 ac wpl 15 acs wpl 15 acs part no. 236645 234759 236639...

14
PRODUCT DATA SHEET WPL 15 ACS AIR | WATER HEAT PUMPS PRODUCT-NO.: 236639 The WPL 15 ACS air | water heat pump is still exceptionally efficient even at temperatures well below freezing point. Its high flow temperatures mean that conventional radiators can be used. It is designed for outdoor use, to provide pleasant warmth from the air, when you would otherwise have to start turning the central heating on. High efficiency on a quiet base: for outdoor installation in particular, low operating noise is essential, especially from the viewpoint of neighbours. The quieter a heat pump operates, the smaller the clearance required to the nearest building. The WPL 15 ACS air | water heat pump scores highly here with its low operating noise, which makes it suitable for use even in densely built-up areas. The main features Air | water heat pump installed outdoors for heating and cooling With energy efficient inverter technology for high flow temperatures even during cold winters Suitable for buildings set closely together thanks to low operating noise Can be combined with a solar thermal system Integral cooling function High energy efficiency class A++ even at a flow temperature of 55 °C

Upload: others

Post on 16-Mar-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

WPL 15 ACSAIR | WATER HEAT PUMPS PRODUCT-NO.: 236639

The WPL 15 ACS air | water heat pump is still exceptionally efficient even at

temperatures well below freezing point. Its high flow temperatures mean that

conventional radiators can be used. It is designed for outdoor use, to provide

pleasant warmth from the air, when you would otherwise have to start turning

the central heating on.

High efficiency on a quiet base: for outdoor installation in particular, low

operating noise is essential, especially from the viewpoint of neighbours. The

quieter a heat pump operates, the smaller the clearance required to the nearest

building. The WPL 15 ACS air | water heat pump scores highly here with its low

operating noise, which makes it suitable for use even in densely built-up areas.

The main features

Air | water heat pump installed outdoors for heating and cooling

With energy efficient inverter technology for high flow temperatures even duringcold winters

Suitable for buildings set closely together thanks to low operating noise

Can be combined with a solar thermal system

Integral cooling function

High energy efficiency class A++ even at a flow temperature of 55 °C

Page 2: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Type WPL 20 A WPL 25 A WPL 25 A

Part no. 236640 232493 236644

Output at A2/W35 (EN 14511) 6,83 kW 8,33 kW 8,33 kW

Output at A-7/W35 (EN 14511) 9,54 kW 12,86 kW 12,86 kW

Coefficient of performance at A2/W35 (EN 14511) 4,00 4,17 4,17

Coefficient of performance at A-7/W35 (EN 14511) 3,26 2,93 2,93

Technical data

Energy efficiency class, heat pump W35 A++ A++ A++

Energy efficiency class, W55 heat pump A++ A++ A++

Energy efficiency class, composite system (heat pump +controller) W35

A++ A+++ A+++

Energy efficiency class, composite system (heat pump +controller) W55

A++ A++ A++

SCOP (EN 14825) 4,30 4,65

Cooling capacity at A35/W7 max.

Cooling capacity factor at A35/W7 max.

Cooling capacity at A35/W7 partial load

Cooling capacity factor at A35/W7 partial load

Sound power level (EN 12102) 54 dB(A) 56 dB(A) 54 dB(A)

Sound pressure level at 5 m distance in a free field 32 dB(A) 34 dB(A) 32 dB(A)

Rated compressor voltage 400 V 400 V 400 V

Rated voltage, emergency/booster heater 400 V 400 V 400 V

Max. application limit on the heating side 65 °C 65 °C 65 °C

Height 1045 mm 1045 mm 1045 mm

Width 1490 mm 1490 mm 1490 mm

Depth 593 mm 593 mm 593 mm

Page 3: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Weight 175 kg 175 kg 175 kg

Page 4: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Type WPL 20 AC WPL 20 AC WPL 25 AC

Part no. 236007 236641 234760

Output at A2/W35 (EN 14511) 6,83 kW 6,83 kW 8,33 kW

Output at A-7/W35 (EN 14511) 9,54 kW 9,54 kW 12,86 kW

Coefficient of performance at A2/W35 (EN 14511) 4,00 4,00 4,17

Coefficient of performance at A-7/W35 (EN 14511) 3,26 3,26 2,93

Technical data

Energy efficiency class, heat pump W35 A++ A++ A++

Energy efficiency class, W55 heat pump A++ A++ A++

Energy efficiency class, composite system (heat pump +controller) W35

A+++ A+++ A+++

Energy efficiency class, composite system (heat pump +controller) W55

A++ A++ A++

SCOP (EN 14825) 4,48

Cooling capacity at A35/W7 max. 11,49 kW 11,49 kW 14,88 kW

Cooling capacity factor at A35/W7 max. 2,53 2,53 2,38

Cooling capacity at A35/W7 partial load 4,80 kW 4,80 kW 4,80 kW

Cooling capacity factor at A35/W7 partial load 2,84 2,84 2,84

Sound power level (EN 12102) 56 dB(A) 54 dB(A) 56 dB(A)

Sound pressure level at 5 m distance in a free field 34 dB(A) 32 dB(A) 34 dB(A)

Rated compressor voltage 400 V 400 V 400 V

Rated voltage, emergency/booster heater 400 V 400 V 400 V

Max. application limit on the heating side 65 °C 65 °C 65 °C

Height 1045 mm 1045 mm 1045 mm

Width 1490 mm 1490 mm 1490 mm

Depth 593 mm 593 mm 593 mm

Page 5: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Weight 175 kg 175 kg 175 kg

Page 6: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Type WPL 25 AC WPL 15 ACS WPL 15 ACS

Part no. 236645 234759 236639

Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW

Output at A-7/W35 (EN 14511) 12,86 kW 6,86 kW 6,86 kW

Coefficient of performance at A2/W35 (EN 14511) 4,17 3,88 3,88

Coefficient of performance at A-7/W35 (EN 14511) 2,93 2,83 2,83

Technical data

Energy efficiency class, heat pump W35 A++ A++ A++

Energy efficiency class, W55 heat pump A++ A++ A++

Energy efficiency class, composite system (heat pump +controller) W35

A+++ A+++ A+++

Energy efficiency class, composite system (heat pump +controller) W55

A++ A++ A++

SCOP (EN 14825) 4,78 4,48

Cooling capacity at A35/W7 max. 14,88 kW 7,86 kW 7,86 kW

Cooling capacity factor at A35/W7 max. 2,38 2,41 2,41

Cooling capacity at A35/W7 partial load 4,80 kW 2,15 kW 2,15 kW

Cooling capacity factor at A35/W7 partial load 2,84 2,39 2,39

Sound power level (EN 12102) 54 dB(A) 55 dB(A) 50 dB(A)

Sound pressure level at 5 m distance in a free field 32 dB(A) 33 dB(A) 28 dB(A)

Rated compressor voltage 400 V 230 V 230 V

Rated voltage, emergency/booster heater 400 V 230 V 230 V

Max. application limit on the heating side 65 °C 65 °C 65 °C

Height 1045 mm 900 mm 900 mm

Width 1490 mm 1270 mm 1270 mm

Depth 593 mm 593 mm 593 mm

Page 7: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Weight 175 kg 140 kg 160 kg

Page 8: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Type WPL 25 ACS WPL 25 ACS WPL 15 AS

Part no. 234761 236643 232491

Output at A2/W35 (EN 14511) 8,32 kW 8,32 kW 4,23 kW

Output at A-7/W35 (EN 14511) 13,05 kW 13,05 kW 6,86 kW

Coefficient of performance at A2/W35 (EN 14511) 3,96 3,96 3,88

Coefficient of performance at A-7/W35 (EN 14511) 2,98 2,98 2,83

Technical data

Energy efficiency class, heat pump W35 A++ A++ A++

Energy efficiency class, W55 heat pump A++ A++ A+

Energy efficiency class, composite system (heat pump +controller) W35

A+++ A+++ A++

Energy efficiency class, composite system (heat pump +controller) W55

A++ A++ A++

SCOP (EN 14825) 4,50

Cooling capacity at A35/W7 max. 14,88 kW 14,88 kW

Cooling capacity factor at A35/W7 max. 2,38 2,38

Cooling capacity at A35/W7 partial load 4,80 kW 4,80 kW

Cooling capacity factor at A35/W7 partial load 2,84 2,84

Sound power level (EN 12102) 56 dB(A) 54 dB(A) 55 dB(A)

Sound pressure level at 5 m distance in a free field 34 dB(A) 32 dB(A) 33 dB(A)

Rated compressor voltage 230 V 230 V 230 V

Rated voltage, emergency/booster heater 230 V 230 V 230 V

Max. application limit on the heating side 65 °C 65 °C 65 °C

Height 1045 mm 1045 mm 900 mm

Width 1490 mm 1490 mm 1270 mm

Depth 593 mm 593 mm 593 mm

Page 9: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Weight 175 kg 175 kg 140 kg

Page 10: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Type WPL 15 AS WPL 25 AS WPL 25 AS

Part no. 236638 232492 236642

Output at A2/W35 (EN 14511) 4,23 kW 8,32 kW 8,32 kW

Output at A-7/W35 (EN 14511) 6,86 kW 13,05 kW 13,05 kW

Coefficient of performance at A2/W35 (EN 14511) 3,88 3,96 3,96

Coefficient of performance at A-7/W35 (EN 14511) 2,83 2,98 2,98

Technical data

Energy efficiency class, heat pump W35 A++ A++ A++

Energy efficiency class, W55 heat pump A+ A++ A++

Energy efficiency class, composite system (heat pump +controller) W35

A++ A+++ A+++

Energy efficiency class, composite system (heat pump +controller) W55

A++ A++ A++

SCOP (EN 14825) 4,20 4,50

Cooling capacity at A35/W7 max.

Cooling capacity factor at A35/W7 max.

Cooling capacity at A35/W7 partial load

Cooling capacity factor at A35/W7 partial load

Sound power level (EN 12102) 50 dB(A) 56 dB(A) 54 dB(A)

Sound pressure level at 5 m distance in a free field 28 dB(A) 34 dB(A) 32 dB(A)

Rated compressor voltage 230 V 230 V 230 V

Rated voltage, emergency/booster heater 230 V 230 V 230 V

Max. application limit on the heating side 65 °C 65 °C 65 °C

Height 900 mm 1045 mm 1045 mm

Width 1270 mm 1490 mm 1490 mm

Depth 593 mm 593 mm 593 mm

Page 11: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Weight 160 kg 175 kg 175 kg

Page 12: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Type WPL 20 A

Part no. 236006

Output at A2/W35 (EN 14511) 6,83 kW

Output at A-7/W35 (EN 14511) 9,54 kW

Coefficient of performance at A2/W35 (EN 14511) 4,00

Coefficient of performance at A-7/W35 (EN 14511) 3,26

Technical data

Energy efficiency class, heat pump W35 A++

Energy efficiency class, W55 heat pump A++

Energy efficiency class, composite system (heat pump +controller) W35

A++

Energy efficiency class, composite system (heat pump +controller) W55

A++

SCOP (EN 14825)

Cooling capacity at A35/W7 max.

Cooling capacity factor at A35/W7 max.

Cooling capacity at A35/W7 partial load

Cooling capacity factor at A35/W7 partial load

Sound power level (EN 12102) 56 dB(A)

Sound pressure level at 5 m distance in a free field 34 dB(A)

Rated compressor voltage 400 V

Rated voltage, emergency/booster heater 400 V

Max. application limit on the heating side 65 °C

Height 1045 mm

Width 1490 mm

Depth 593 mm

Page 13: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Weight 175 kg

Page 14: WPL 15 ACS...PRODUCT DATA SHEET Type WPL 25 AC WPL 15 ACS WPL 15 ACS Part no. 236645 234759 236639 Output at A2/W35 (EN 14511) 8,33 kW 4,23 kW 4,23 kW Output at …

PRODUCT DATA SHEET

Contact information

You have questions? We appreciate to help you:

Call +49 5531 - 7020

Write an email to [email protected]

Installation information

Please ask your local power supply utility or a registered electrician to install

appliances that are not fully wired, i.e. ready to plug in. The electrician should

also be able to assist you with obtaining the agreement of the respective power

supply utility required for the appliance installation.