wpc pergola installation instructions · suh guloowkhlqqhudoxplqxp step:3. 9 note :the drain holes...

15
Option A Option B INSTALLATION INSTRUCTIONS WPC PERGOLA 10’x10’

Upload: others

Post on 24-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

Option A

Option B

INSTALLATION INSTRUCTIONS WPC PERGOLA10’x10’

Page 2: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

269m

m/10

.59”

269mm/10.59”

Base plate cover

3048mm/120’’

3048mm/120’’3048mm/120’’

2052mm/80.76”

2454mm/96,6” 2454mm/96,6”

2835mm/111.6”

Page 3: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

L1: U-clip X16L2: M8 60mm screw bolt X16L3: L-angle clip X105L4: 4.2X25mm screw X270L5: Expansion screw X16L6: M10 treaded rod X12L7: 3.8X25mm screw X40

Base plate cover X4

Drill

Page 4: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

Straight line

Straight line

Mark line

The hole size

Mark point

Z=3537mm/139.2''

16 0.629

A:Steel inner post

According to the measurement, please put the steel inner post (A)on the ground. ATTENTION: The ground should be flat.

STEP:1 STEP:2

ZZ

198m

m7.8’

’19

8mm7

.8’’

Betw

een8

0-90

mm

(3

.15’’-3

.55’’)

2501mm/98.4”

2501

mm/98

.4”

2105mm/82.8”21

05mm

/82.8”

attentionNote:Please drill the holes as the diagram shown.

Drill the points

Straight lineStraight line

Page 5: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

Straight line

Straight line

Put the posts on the expansion screws (L5)

Fix the expansion screws (L5)

L5Note: Please be careful not to break the base

plate cover.

Put the B over the A. When touching th WPCpart, please wear gloves, in case there is oil on the WPC posts.

Before fixing the posts to the ground, refer to the front page of the guide (option A or option B), using the pre-drilled holes on the end of the posts, choose the orientation of the desired roof structure.

same

STEP:3 STEP:4

STEP:5

2

4

Straight line Straight line

same

Page 6: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

Measure and adjust until the following requirements.

Measure the distance between the posts and the length is 2454mm/102”.

1.Use the Level to ensure the a side and b side of the posts must be vertical to the ground.Please adjust if necessary.

Use the wrench to fix the expansion screws (L5)

2.The ground should be flat.

Straight line

Straight line

2454mm/102”

2454

mm/10

2”

5

STEP:6

STEP:7

STEP:8

3

Straight line Straight line

Post Installation A & B

Page 7: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

Put the base plate covers (H) on the WPC posts.

6

2454mm/102”2454mm/102”

2454mm/102”

2454mm/102”

Measure again

B

STEP:9

Page 8: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

STEP:1

7

Assemble the treaded rod (L6) and the U-Clips (L1) as the diagram shown.

STEP:2Install the cross beams (C) with the treaded rod (L6) and the U-clips (L1).

8 pieces 4 pieces

L6

L1

middle

top

bottom

Note: Please adjust the distance between the posts according to the holes position on the C.

Page 9: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

8

L7

L7

L7

Note: Keep the screws (L7) parallel to the cross beam (C).

Keep Parallel

Keep Parallel

L7 L7

Please pre-drill the holes for the screws (L7) with Φ4mm(Φ0.2”) and fix the screws (L7). Please do not pre-drill the inner aluminum.

STEP:3

Page 10: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

9

Note :The drain holes must be downwards.

Install the beams 2 (F) to the cross beams (C) with the U-Clips (L1) and the screws bolt (L2).

Note: Please use the wrench tofix the L2 go through the holes of the F tightly.

Beam F installation

Page 11: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

10

Note :The drain holes must be downwards.

Pre-drill the holes on the beam 2 (F), please do not pre-drill the inner aluminum.Fixing the U-Clips (L1) and screws (L7) with the holes we pre-drill as the diagram shown.

Use the wrench to install the beam 3 (G) with the screws bolt (L2) tightly.

Fix the beam 3 (G) according to the 6 cuts of the beam 1-2 (E).

L7 L7

L7

L7

Keep Parallel

Keep Parallel

Beam G installation

Page 12: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

11

7

D

L4

L3Fix the L-angle clips (L3) and the screws (L4) to the beams (D).

STEP:1Fix the L-angle clips (L3) and the screws (L4) to the beams (D).

Put the beams (D) on the cross beams (C), one piece on each side.

Beam D installation

Page 13: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

L4

Aluminium

The hole Φ5mm

WPC

Aluminium

WPC

12

STEP:2

STEP:3

Pre-drill the cross beams (C). ATTENTION: Do not pre-drill the inner aluminum.

Measure the distance of the cross beams (C) as the diagram shown which is 222mm/8.74” and mark the points.

222m

m/8

.74”

222m

m/8

.74”

Fix the screws (L4) on the cross beams (C).

Page 14: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

Adjust the distance between the two pieces of the beam 1-2 (E), the distance “P” is 269mm/10.59” and mark the points.

E×7

E

PP

PP

PP

PP

8

STEP:1

There are 6 cuts on each pieces. Please adjust the cuts to fit onto the cross beams (C).

13

Beam (E)

L4

L3Fix the L-angle clips (L3) and the screws (L4) to the beams (E).

Beam E installation

Page 15: WPC PERGOLA INSTALLATION INSTRUCTIONS · SUH GULOOWKHLQQHUDOXPLQXP STEP:3. 9 Note :The drain holes must ... (L2) tightly. Fix the beam 3 (G) according to the 6 cuts of the beam 1-2

M M

N

Pre-dril the points on the WPC beam and do not pre-drill the inner aluminum.

Fix the screws (L4) and measure again the distance as the Page 1 show.

STEP:2

STEP:3

Aluminium

The hole Φ5mm

WPC

Aluminium

WPC

L4

Fix the screws (L4) on the cross beams (C).

14