WP12 Safety IEC60601-approved,CE marking to MDD93/42 /EEC Dimension and Weight Dimension: 375(W) 350 (H) 300(D)mm Weight: 6.5kg Operation Environment Power Requirement: AC100-240V(10%),50/60Hz( 3Hz),140VA Temperature 0 40 Humidity 15% 80%(non-condensing) Patient range Neonate, Pediatric and Adult Performance Specifications Display: 12.1'' colorful TFT LED, High brightness Rolling and refreshing waveform display Resolution:800*600 Multi displays selectable, including Standard display Trend coexist display Large-font display OxyCRG dynamic view display Trace: 7traces Sweep speed:12.5mm/s,25mm/s,50mm/s Indicator: Alarm indicator light Power indicator light Battery indicator light QRS beep and alarm sound Interface: Parameter cable interface AC Power input socket Network interface External VGA interface for connection of an Li-ion Battery: Rechargeable (one piece) Maximum 4 hours forcharging( switched off) Maximum 8 hours for charging(switched on) 5 hours for continuous working Trend time: 168 hours Alarm: User-adjustable High, Medium, Low limits 3-level Audible and visual alarm Networking: Connected to central station system Recorder: Thermal array Waveform:4 Channel(standard) Record mode: manual, on alarm, time-defined, etc Paper width:50mm Print speed:25mm/s ECG 3-Lead or 5-Lead selectable Input: 3 leadwire cable: RA;LA;LL or R;L;F 5 leadwire cable: RA;LA;RL;LL;V or R;L;N;F;C Lead selection: 3-lead: , , 5 lea d: , , , , AVR, A VL, AVF ECG Waveform 2 channel Gain selection 0.25, 0.5, 1, 2, 4,Auto Sweep speed 12.5mm/s,25mm/s,50mm/s Heart Rate for Neonate/Pediatric 15-350BPM Heart Rate for Adult 15-300BPM Accuracy 1bpm or 1%,whichever is greater Resolution 1bpm Filter Diagnostic mode:0.05-100Hz Monitor mode:0.5-40Hz Surgical mode:1.0-25Hz Protection Withstand 8000VAC/50Hz Votage in isolation Against electrosurgical interference and defibrillation Scaling signal: 1Mv marker,0.5Mv marker,0.25Mv marker Alarm range: 15-350bpm ST segment detection: Measurement range:-2.0mv to 2.0mv Alarm range:-2.0mv to 2.0mv Arrythmia analysis: Measurement range:-2.0mv to 2.0mv Alarm range:-2.0mv to 2.0mv Arrythmia analysis: Yes Alarm Yes, audible and visual alarm, alarm event recallable Pace detection Yes Pace rejection width 0.1ms 2ms Drug does calculation Yes Standby mode Yes : : : : : : : : : : : : Respiration Method: Thoracic impedance Measurement range: Neonate:7 150rpm Adult:7 120rpm Apnea alarm : No alarm,10s,15s,20s,25s, 30s,35s,40s selectable Alarm: Yes, audible and visual alarm, alarm events recallable NIBP Method: Oscillometric Measurement modes: Manual/Automatic/Continuous Displayed parameters Systolic, diastolic and MAP Auto measure time: Adjustable Measurement unit mmHg/kPa selectable Measurement type: Systolic, Diastolic, Mean Range of Systolic pressure Adult:40-270mmHg Pediatric:40-200mmHg Neonate:40-135mmHg Range of Diastolic pressure Adult:10-210mmHg Pediatric:10-150mmHg Neonate:10-95mmHg Range of Mean pressure Adult:20-230mmHg Pediatric:20-165mmHg Neonate:20-110mmHg Accuracy: 5mmHg Resolution: 1mmHg Alarm: Systolic, Diastolic, Mean Over-pressure protection: Double safety protection SpO2 Measurement range: 0% 100% Resolution: 1bpm Accuracy: 2%(70%-100%);unspecified(0-69%) Alarm range: 0% 100% Pulse rate: Range:20bpm 254bpm Resolution:1bpm Accuracy: 3bpm Alarm range:0 254bpm Temperature Measurement range: 0 50 Resolution: 0.1 Accuracy: 0.1 Channel: T1 T2 TD IBP Channels 1 or 2 selectable Measurement range -50 400mmHg Resolution: 1mmHg Accuracy: 1mmHg or 2%,whichever is greater(without sensor) Pressure names: ART,PA,CVP,RAP,LAP,ICP Alarm range: -50 400mmHg Pressure transducer Sensitivity: 5mv/v/mmHg Impedance range: 300-3000w EtCO2 Measurement range 0-99mmHg Accuracy: 0 to 40mmHg 2mmHg 41 to 76mmHg 5% of the reading 77 to 99mmHg 10% of the reading Sampling rate: 50ml/min or 100ml/min Sampling rate accuracy 15% or 15ml/min, whichever is greater Start-up time: 1min,once the module starts up, it reaches ISO, After 1 min, enter the full accuracy mode Respiration rate: 0 to120rpm Respiration rate accuracy 2 rpm Response time: 240msec(10% to 90%) Standard Configuration: ECG,SpO2,NIBP, TEMP,PR/HR,RESP Optional Functions: EtCO2,2IBP,Recorder , Touch screen, C.O.,Multi-gas, CMS Model:

Upload: others

Post on 11-Dec-2021

37 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WP12 - img1.wsimg.com

WP12

SafetyIEC60601-approved,CE marking to MDD93/42/EECDimension and WeightDimension: 375(W) 350 (H) 300(D)mmWeight: 6.5kg

Operation EnvironmentPower Requirement: AC100-240V(10%),50/60Hz( 3Hz),140VA

Temperature 0 40 Humidity 15% 80%(non-condensing) Patient range Neonate, Pediatric and Adult Performance SpecificationsDisplay: 12.1'' colorful TFT LED, High brightness Rolling and refreshing waveform display Resolution:800*600 Multi displays selectable, including Standard display Trend coexist display Large-font display OxyCRG dynamic view displayTrace: 7traces Sweep speed:12.5mm/s,25mm/s,50mm/sIndicator: Alarm indicator light Power indicator light Battery indicator light QRS beep and alarm soundInterface: Parameter cable interface AC Power input socket Network interface External VGA interface for connection of anLi-ion Battery: Rechargeable(one piece) Maximum 4 hours for charging( switched off) Maximum 8 hours for charging(switched on) 5 hours for continuous workingTrend time: 168 hoursAlarm: User-adjustable High, Medium, Low limits 3-level Audible and visual alarmNetworking: Connected to central station systemRecorder: Thermal array Waveform:4 Channel(standard) Record mode: manual, on alarm, time-defined, etc Paper width:50mm Print speed:25mm/sECG 3-Lead or 5-Lead selectableInput: 3 leadwire cable: RA;LA;LL or R;L;F 5 leadwire cable: RA;LA;RL;LL;V or R;L;N;F;CLead selection: 3-lead: , ,5 lea d: , , , , AVR, AVL, AVFECG Waveform 2 channelGain selection 0.25, 0.5, 1, 2, 4,AutoSweep speed 12.5mm/s,25mm/s,50mm/sHeart Rate for Neonate/Pediatric 15-350BPMHeart Rate for Adult 15-300BPMAccuracy 1bpm or 1%,whichever is greaterResolution 1bpmFilter Diagnostic mode:0.05-100Hz Monitor mode:0.5-40Hz Surgical mode:1.0-25HzProtection Withstand 8000VAC/50Hz Votage in isolation Against electrosurgical interference and defibrillationScaling signal: 1Mv marker,0.5Mv marker,0.25Mv markerAlarm range: 15-350bpmST segment detection: Measurement range:-2.0mv to 2.0mv Alarm range:-2.0mv to 2.0mvArrythmia analysis: Measurement range:-2.0mv to 2.0mv Alarm range:-2.0mv to 2.0mvArrythmia analysis: YesAlarm Yes, audible and visual alarm, alarm event recallablePace detection YesPace rejection width 0.1ms 2msDrug does calculation YesStandby mode Yes

::

::

::

:

:

::

::

RespirationMethod: Thoracic impedanceMeasurement range: Neonate:7 150rpm Adult:7 120rpmApnea alarm : No alarm,10s,15s,20s,25s, 30s,35s,40s selectableAlarm: Yes, audible and visual alarm, alarm events recallable

NIBPMethod: OscillometricMeasurement modes: Manual/Automatic/ContinuousDisplayed parameters Systolic, diastolic and MAPAuto measure time: AdjustableMeasurement unit mmHg/kPa selectableMeasurement type: Systolic, Diastolic, MeanRange of Systolic pressure Adult:40-270mmHg Pediatric:40-200mmHg Neonate:40-135mmHgRange of Diastolic pressure Adult:10-210mmHg Pediatric:10-150mmHg Neonate:10-95mmHgRange of Mean pressure Adult:20-230mmHg Pediatric:20-165mmHg Neonate:20-110mmHgAccuracy: 5mmHgResolution: 1mmHgAlarm: Systolic, Diastolic, MeanOver-pressure protection: Double safety protection

SpO2Measurement range: 0% 100%Resolution: 1bpmAccuracy: 2%(70%-100%);unspecified(0-69%)Alarm range: 0% 100%Pulse rate: Range:20bpm 254bpm Resolution:1bpm Accuracy: 3bpm Alarm range:0 254bpmTemperatureMeasurement range: 0 50Resolution: 0.1Accuracy: 0.1Channel: T1 T2 TD

IBPChannels 1 or 2 selectableMeasurement range -50 400mmHgResolution: 1mmHgAccuracy: 1mmHg or 2%,whichever is greater(without sensor)Pressure names: ART,PA,CVP,RAP,LAP,ICPAlarm range: -50 400mmHgPressure transducerSensitivity: 5mv/v/mmHgImpedance range: 300-3000w

EtCO2Measurement range 0-99mmHgAccuracy: 0 to 40mmHg 2mmHg 41 to 76mmHg 5% of the reading 77 to 99mmHg 10% of the readingSampling rate: 50ml/min or 100ml/minSampling rate accuracy 15% or 15ml/min, whichever is greaterStart-up time: 1min,once the module starts up, it reaches ISO, After 1 min, enter the full accuracy modeRespiration rate: 0 to 120rpmRespiration rate accuracy 2 rpmResponse time: 240msec(10% to 90%)

Standard Configuration: ECG,SpO2,NIBP,TEMP,PR/HR,RESPOptional Functions: EtCO2,2IBP,Recorder, Touch screen, C.O., Multi-gas, CMS

Model: