workshop steyr, 2005 potential new technologies and testing of mobile water treatment units

16
WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

Upload: merryl-lane

Post on 12-Jan-2016

223 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005

Potential New Technologies And Testing Of Mobile Water Treatment Units

Page 2: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005

Scope of the workshop• achieve an overview on suppliers and

technologies• potential to be used by RC / RC• correspond to our standardized

Specialized WatSan ERU

Page 3: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005

Specialized WatSan ERU• Water production 120.000 l/day• Minimum quality: WHO standards• Capability to treat high turbidity• Capability to treat high microbiological

contamination• Simple to operate, easy to maintain

Page 4: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005

Participating companies• SETA www.gruposeta.com • Berkefeld www.berkefeld.de

• Scan-Water www.scan-water.com

• Josab www.josab.com

• Kaercher www.kaercher-futuretech.com

Page 5: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005Preparation of raw water

• First day: turbidity

• Second day: microbiology

Page 6: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005

SETA 3000• Pretreatment• Sand filter• Active carbon filter• Chlorination

Page 7: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005SETA 3000• Compact on a trailer• Pretreatment able to handle high turbidity• Safe drinking water• Consumables: Alum, HTH

Page 8: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005

Scan-Water Purification unit 4 m3/hr• Flocculation / Coagulation unit• Sand filter• Active carbon filter• Chlorination

Page 9: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005

Scan-Water Purification unit 4 m3/hr• Very easy to operate• Simple unit• With additional pretreatment able to handle turbidity• Good price – performance ratio

Page 10: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005

Josab Aqualite Portable Pro (500 l/hr)

• No pretreatment• Aqualite (zeolite structure)

filter• UV radiation• Post-Chlorination

Page 11: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005Josab Aqualite Portable Pro (500 l/hr)

• Best results for microbiological tests• Quick to install• Struggles with high turbidity• Chlorination possible

Page 12: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005Kaercher RO WTC 500 + Filatwist• Prefiltration with filter-bag• Prefilter Filatwist (up to 4 m3/hr) in development• Reverse Osmosis• UV radiation• Post-Chlorination

Page 13: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005Kaercher RO WTC 500 + Filatwist• Prefilter Filatwist demonstration unit / in development• Prefiltration Filter-bag clogs immediately• Reverse Osmosis needs clear water• High-tech machinery• High costs – Low output

Page 14: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005

Berkefeld BERU 2000/700

• Pretreatment with disc-filter• Ultrafiltration• Reverse Osmosis (optional)• Fully automatic• Trailer mounted (optional)

Page 15: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005Berkefeld BERU 2000/700• Long time for start up• Broke when becoming operational• Material defect, no repair possible• Risk of control system failure?• Trailer not practical option

Page 16: WORKSHOP Steyr, 2005 Potential New Technologies And Testing Of Mobile Water Treatment Units

WORKSHOP Steyr, 2005Overall comments• Simple technology suits best• High turbidity requires pretreatment• Microbiological tests ok for all units• Post-chlorination necessary in emergencies• Different solutions regarding comfort and material • SETA and Scan-Water with best results