worcster street page 28 of 33 5 5 5 5 rma/2016/2390 ... · proposed north elevation1:100-proposed...

6
Page 28 of 33 RMA/2016/2390 Approved Resource Consent Document 28/09/2016

Upload: others

Post on 24-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Worcster Street Page 28 of 33 5 5 5 5 RMA/2016/2390 ... · Proposed North Elevation1:100-Proposed East Elevation1:100 Page 31 of 33 RMA/2016/2390 Approved Resource Consent Document

Page 28 of 33

RMA/2016/2390

Approved Resource Consent Document

28/09/2016

Page 2: Worcster Street Page 28 of 33 5 5 5 5 RMA/2016/2390 ... · Proposed North Elevation1:100-Proposed East Elevation1:100 Page 31 of 33 RMA/2016/2390 Approved Resource Consent Document

GSPublisherEngine 1335.23.26.100

Architectural Designers & Project Management Services

Revision Notes: TITLE: Ground Floor / Dim Plan

Client:

Address:

Williams Specialised Property

Worcester Street

Linwood

Christchurch

Scale:

Drawn By:

As Shown @ A1

Start Date:

Print Date:

14/09/2016

15-Feb-18

SheetRevision MV

3BW

ALL DIMENSIONS SHOWN ON DRAWINGS ,COUNCIL (PUBLIC) DRAIN

POSITIONS AND INVERTS SHALL BE CONFIRMED BY CONTRACTOR PRIOR

TO ANY WORKS COMMENCING. NOTIFY URBAN DESIGN NZ LTD SHOULD

DIMENSIONS OR POSITIONS VARY TO THAT SHOWN IMMEDIATELY.

IF GROUND CONDITIONS ARE QUESTIONABLE AND ARE NOT IN

ACCORDANCE WITH NZBC OR NZS 3604:2011REQUIREMENTS STOP

WORK AND CONTACT DESIGNER IMMEDIATELY.

NOTES:

ROOF TRUSS AND BRACING IS INDICATIVE ONLY AND SHALL BE

DESIGNED AND DETAILED BY APPROVED GANGNAIL TRUSS

MANUFACTURER IN ACCORDANCE WITH GANG-NAIL NZ LIMITED

NZ500 AND NZS 3604 : 2011

FOR WIND BRACING AND TYPE REFER TO ADJOINING SPECS

LINTELS TO BE 24% MAX MOISTURE CONTENT .TIMBER SIZES AS

PER NZS 3604 : 2011

KITCHEN JOINERY MANUFACTURER SHALL TAKE ' ON SITE '

MEASUREMENTS PRIOR TO FABRICATION.

FOR KITCHEN LAYOUT AND JOINERY REFER TO KITCHEN

MANUFACTURERS DOCUMENTS.

ALL GLASS TO BE AS PER NZS 4223 (PART 3 IN PARTICULAR)

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NZBC HAND

BOOK AND APPROVED DOCUMENTS ,NZS 3604 : 2011 AND LOCAL

TERRITORIAL AUTHORITY REQUIREMENTS.

WINDOW MANUFACTURERS SHALL CHECK ' ON SITE ' ALL WINDOW

OPENING SIZES PRIOR TO FABRICATION.

ALL PLUMBING AND DRAINAGE WORK SHALL BE IN ACCORDANCE

WITH NZBC REQUIREMENTS AND APPROVED DOCUMENTS.

VENTILATION TO FOUNDATION WALLS TO COMPLY TO NZS 3604

SECTION 4.8.

SHOULD THERE BE ANY AMBIGUITY ON THE DRAWINGS AND/OR

ACCOMPANYING DOCUMENTATION, OR THE MEANING(S) IS(ARE)

UNCLEAR OR IF THERE IS APPARENT CONFLICTING INFORMATION

SHOWN, IMMEDIATELY NOTIFY URBAN DESIGN NZ LTD BEFORE

COMMENCING THE WORK.

Z:\Urban Design NZ LTD\Urban Design Plans\ARCHICAD V18\378 - WilliamsHomes - Worcster Street\Drawing Files\V18.377 - WilliamsHomes - Worcster Street - Bathroom Change - 20180215.pln

This Drawing remains the property of Urban Design Ltd.

It must not be used, copied or handed to any third party

without the written permission of Urban Design Ltd

The Contractor shall check and verify all dimensions and

levels prior to commencing any work.

All construction shall be in accordance with NZS 3604,

unless specifically Engineered, and in accordance with

the current Building Act.

RC - RMA/2016/2390

ALL PROPOSED SED CONCRETE WORK TO BE 25 MPa

MV - Revised: 15/02/2018

2,1

00 x

1,6

00

2,100 x 1,6002,100 x 1,6002,100 x 1,6002,100 x 1,600

MV

MVMVMVMV

30,895

6,230 6,425 6,425 6,425 5,390

18,0

30

140

1,9

00

90

3,3

81

90

11,7

40

90

510

90

30,895

6,230 6,425 6,425 6,425 68 140 5,043 140

18,0

30

140

5,3

70

11,8

30

90

510

90

140338

140 4,900 140 1,145 140 5,000 140 1,145 140 5,000 140 1,145 140 5,000 140 1,145 140 3,965 140 432 140

140 5,865 225 225 5,975 225 225 5,975 225 225 5,975 22568

140 5,043

140 3,100 90 2,900 225 3,100 90 3,010 225 3,100 90 3,010 225 3,100 90 3,010 68 140 3,100 90 1,853 140

5,5

10

12,5

20

90

1,9

00

90

140 3,100 90 450 3,100 90 225 225 3,100 90 225 225 3,100 90

1,600 1,600 1,600 1,600

1,6

00

building overall

wall set out

gri

d lin

es

wall s

et

out

building overall

grid lines

grid lines

buildin

g o

vera

ll

wall set out

wall set out

buildin

g o

vera

ll

gri

d lin

es

UNIT 1UNIT 2

up

UNIT 4 UNIT 3UNIT 5

stairs

services

E FDCBA

N

M

O

services services services

serv

ices

NOTE: doors to have a minimumopening width of 760mm as perD1/AS1 - allow for door & jambthickness. Contractor to confirmprior to ordering joinery

-

Ground Floor Dimension 1:50

Page 3: Worcster Street Page 28 of 33 5 5 5 5 RMA/2016/2390 ... · Proposed North Elevation1:100-Proposed East Elevation1:100 Page 31 of 33 RMA/2016/2390 Approved Resource Consent Document

Page 30 of 33

RMA/2016/2390

Approved Resource Consent Document

28/09/2016

Page 4: Worcster Street Page 28 of 33 5 5 5 5 RMA/2016/2390 ... · Proposed North Elevation1:100-Proposed East Elevation1:100 Page 31 of 33 RMA/2016/2390 Approved Resource Consent Document

Page 31 of 33

RMA/2016/2390

Approved Resource Consent Document

28/09/2016

Page 5: Worcster Street Page 28 of 33 5 5 5 5 RMA/2016/2390 ... · Proposed North Elevation1:100-Proposed East Elevation1:100 Page 31 of 33 RMA/2016/2390 Approved Resource Consent Document

Page 32 of 33

RMA/2016/2390

Approved Resource Consent Document

28/09/2016

Page 6: Worcster Street Page 28 of 33 5 5 5 5 RMA/2016/2390 ... · Proposed North Elevation1:100-Proposed East Elevation1:100 Page 31 of 33 RMA/2016/2390 Approved Resource Consent Document