wolf fb-a ceiling mounted ventilation units: comfort temperature

8
Ceiling Air Units FB-A: whisper-quiet, economical, reliable Comfort Temperature Heizung - Lüftung - Klimatechnik Heating - Ventilation - Air Conditioning … the most beautiful side of air

Upload: wolf-anlagen-technik

Post on 06-Feb-2016

228 views

Category:

Documents


0 download

DESCRIPTION

Heating and cooling for exhibition and reception rooms, supermarkets, shopping centres, stores, furniture shops, greenhouses, offices etc. with room heights of approx. 2,5 to 5 m.

TRANSCRIPT

Page 1: WOLF FB-A Ceiling Mounted Ventilation Units: Comfort Temperature

Ceiling Air Units FB-A: whisper-quiet, economical, reliableComfort Temperature

Heizung - Lüftung - KlimatechnikHeating - Ventilation - Air Conditioning

… the most beautiful side of air

Page 2: WOLF FB-A Ceiling Mounted Ventilation Units: Comfort Temperature

2* Heating = Cooling =

Air guidance lamellae removable for maintenance

Heating and cooling for exhibition and reception rooms, supermarkets, shopping centres, stores, furniture shops, greenhouses, offices etc. with room heights of approx. 2,5 to 5 m.

in attractive design

Hub motor of the quietly running axial fan with sickle blades

FB-A Ultra Ceiling Air Units for Heating and Cooling

Installation FB-A-K Ultra

Housing cover

Condensate tub with Armaflex insulation

Splash protection

Heater / Radiator

Axial fan

Housing floorSwitching box

Pump

Ceiling Air Units FB-A Ultra

Construction size 600 700 800

Type 623-6 633-6 625-6 635-6 635-6-K 626-6 636-6 723-6 733-6 725-6 735-6 735-6-K 726-6 736-6 823-6 833-6 825-6 835-6 835-6-K 826-6 836-6

Kind of operation*

Air capacity m³/h 1950 1930 1650 1530 1320 1650 1530 2940 2900 2695 2550 2305 2695 2550 3990 3665 3750 3400 2950 3750 3400

Voltage V, 50 Hz 230 400 230 400 230 400

Rotational speed U/min. 1240 900 / 700 910 / 720 1300 900 / 750 890 / 700 890 650 / 490 670 / 500

Motor performance kW 0,22 0,04 / 0,03 0,05 / 0,033 0,45 0,11 / 0,07 0,45 0,17 / 0,10 0,16 / 0,095

Power input A 1,0 0,11 / 0,05 0,11 / 0,05 0,13 / 0,07 1,90 0,27 / 0,13 0,27 / 0,13 0,28 / 0,15 2,10 0,47 / 0,21 0,38 / 0,09

Heat exchanger 2 rows 3 rows 2 rows 3 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 3 rows 2 rows 3 rows

Heating capacity kW 4,8 - 26,9 5,4 - 33,9 2,7 - 26,9 3,2 - 33,9 2,8 - 31,0 2,7 - 26,9 3,2 - 33,9 5,8 - 38,8 7,2 - 51,7 6,6 - 40,8 8,1 - 52,6 5,6 - 49,0 6,6 - 40,8 8,1 - 52,6 6,6 - 50,3 8,0 - 64,3 9,3 - 56,5 10,4 - 72,1 7,5 - 52,3 9,3 - 56,5 10,4 - 72,1

Cooling capacity kW 1,1 - 11,1 2,2 - 17,7 2,7 - 23,0

Sound level in 3 m 57 dB(A) 44 dB(A) 44 dB(A) 45 dB(A) 58 dB(A) 45 dB(A) 45 dB(A) 46 dB(A) 61 dB(A) 46 dB(A) 46 dB(A) 47 dB(A)

Weight 38 kg 40 kg 38 kg 40 kg 56 kg 38 kg 40 kg 44 kg 47 kg 44 kg 47 kg 63 kg 44 kg 47 kg 49 kg 54 kg 49 kg 54 kg 68 kg 49 kg 54 kg

Diameter 945 mm 1030 mm 1290 mm

Height 255 mm 305 mm 255 mm 255 mm 255 mm 305 mm 255 mm 255 mm 305 mm 255 mm

Height with suction flashing 336 mm 386 mm 336 mm 336 mm 336 mm 386 mm 336 mm 336 mm 386 mm 336 mm

Page 3: WOLF FB-A Ceiling Mounted Ventilation Units: Comfort Temperature

3 FB-A Ultra

FB-A Ultra and Ultra plus

FA-A Ultra with recirculating air suction grid

Consistent Heat or Comfortable Coolness Type „Ultra“ is fulfilling technically and optically high demands. It is impressive even in exclusive ambience.

Ultra is blowing out horizontally on six sides with 15° inclination, reaching an especially consistent distribution of the tempered air in the room.

Ceiling air units FB-A Ultra are rated for pure heating operation or for combined heating / cooling operation (FB-A-K).

Units with cooling function are equipped with a condensate tub below the cooling register and a condensate pump.

Air capacity up to 3750 m³/h

Heating capacita up to 40 kW

Cooling capacity up to 19,9 kW

Especially quiet by sickle blades Lateral blow-out Suction possible above or below the ceiling Connection heating medium above Air guiding lamellae individually adjustable Condensate pump Condensate tub Delivery completely wired and piped Recirculating, mixed and outside air operation Control System WOLF-Tronic

Ceiling Air Units FB-A Ultra

Construction size 600 700 800

Type 623-6 633-6 625-6 635-6 635-6-K 626-6 636-6 723-6 733-6 725-6 735-6 735-6-K 726-6 736-6 823-6 833-6 825-6 835-6 835-6-K 826-6 836-6

Kind of operation*

Air capacity m³/h 1950 1930 1650 1530 1320 1650 1530 2940 2900 2695 2550 2305 2695 2550 3990 3665 3750 3400 2950 3750 3400

Voltage V, 50 Hz 230 400 230 400 230 400

Rotational speed U/min. 1240 900 / 700 910 / 720 1300 900 / 750 890 / 700 890 650 / 490 670 / 500

Motor performance kW 0,22 0,04 / 0,03 0,05 / 0,033 0,45 0,11 / 0,07 0,45 0,17 / 0,10 0,16 / 0,095

Power input A 1,0 0,11 / 0,05 0,11 / 0,05 0,13 / 0,07 1,90 0,27 / 0,13 0,27 / 0,13 0,28 / 0,15 2,10 0,47 / 0,21 0,38 / 0,09

Heat exchanger 2 rows 3 rows 2 rows 3 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 3 rows 2 rows 3 rows

Heating capacity kW 4,8 - 26,9 5,4 - 33,9 2,7 - 26,9 3,2 - 33,9 2,8 - 31,0 2,7 - 26,9 3,2 - 33,9 5,8 - 38,8 7,2 - 51,7 6,6 - 40,8 8,1 - 52,6 5,6 - 49,0 6,6 - 40,8 8,1 - 52,6 6,6 - 50,3 8,0 - 64,3 9,3 - 56,5 10,4 - 72,1 7,5 - 52,3 9,3 - 56,5 10,4 - 72,1

Cooling capacity kW 1,1 - 11,1 2,2 - 17,7 2,7 - 23,0

Sound level in 3 m 57 dB(A) 44 dB(A) 44 dB(A) 45 dB(A) 58 dB(A) 45 dB(A) 45 dB(A) 46 dB(A) 61 dB(A) 46 dB(A) 46 dB(A) 47 dB(A)

Weight 38 kg 40 kg 38 kg 40 kg 56 kg 38 kg 40 kg 44 kg 47 kg 44 kg 47 kg 63 kg 44 kg 47 kg 49 kg 54 kg 49 kg 54 kg 68 kg 49 kg 54 kg

Diameter 945 mm 1030 mm 1290 mm

Height 255 mm 305 mm 255 mm 255 mm 255 mm 305 mm 255 mm 255 mm 305 mm 255 mm

Height with suction flashing 336 mm 386 mm 336 mm 336 mm 336 mm 386 mm 336 mm 336 mm 386 mm 336 mm

Page 4: WOLF FB-A Ceiling Mounted Ventilation Units: Comfort Temperature

4

FB-A Ultra plus

FB-A Ultra plus

Ceiling Air Units FB-A de luxe

Construction size 600 700 800

Type 623 633 621 631 626 636 723 733 721 731 726 736 823 833 821 831 826 836

Betriebsart*

Air capacity m³/h 1950 1930 1950 1930 1400 1350 2940 2900 2940 2900 2180 2120 3990 3665 3990 3665 2810 2620

Voltage V, 50 Hz 230 400 400 230 400 400 230 400 400

Rotational speed U/min 1240 1320 / 1000 910 / 720 1300 1330 / 1020 890 / 700 890 890 / 680 670 / 500

Motor performance kW 0,22 0,11 / 0,08 0,05 / 0,033 0,45 0,29 / 0,21 0,11 / 0,07 0,45 0,35 / 0,25 0,16 / 0,095

Power input A 1,0 0,20 / 0,12 0,13 / 0,07 1,90 0,50 / 0,32 0,28 / 0,15 2,10 0,80 / 0,46 0,38 / 0,09

Heat exchanger 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows

Heating capacity kW 3,9 - 27,0 4,8 - 35,9 3,9 - 27,0 4,8 - 35,9 3,0 - 23,0 4,0 - 30,9 5,8 - 38,8 7,2 - 51,7 5,8 - 38,8 7,2 - 51,7 4,7 - 33,2 6,4 - 38,3 8,4 - 52,7 9,6 - 67,3 8,4 - 52,7 9,6 - 67,3 6,3 - 49,3 8,7 - 62,3

Sound level in 3 m 56 dB(A) 48dB(A) 61 dB(A) 54 dB(A) 60 dB(A) 53 dB(A)

Weight Variant H 23 kg 25 kg 23 kg 25 kg 23 kg 25 kg 35 kg 37,5 kg 35 kg 37,5 kg 35 kg 37,5 kg 42 kg 45 kg 42 kg 45 kg 42 kg 45 kg

Weight Variant V 27,5 kg 29,5 kg 27,5 kg 29,5 kg 27,5 kg 29,5 kg 41,5 kg 44 kg 41,5 kg 44 kg 41,5 kg 44 kg 50 kg 53 kg 50 kg 53 kg 50 kg 53 kg

Length by width 600 x 568 mm 750 x 718 mm 850 x 810 mm

Height Variant H1 254 mm 260 mm 266 mm

Height Variant H2 267 mm 273 mm 279 mm

Height Variant V 378 mm 378 mm 378 mm

Enormously powerful Type „Ultra plus“ of series FB-A is extending series Ultra by a diagonal fan unit for hightest air capacities.

Due to diagonal air flow and favourable sound behaviour, the FB-A Ultra plus ceiling units can used wherever the capa-city of FB-A Ultra units with their low pressure axial fans isn‘t sufficient any more.

Ultra plus will make it even for larger rooms without efforts - and especially quiet.

Moreover, the special scoop shape of the fan wheel is extremely energy-saving.

with High-Performance Fan

Air capacity up to 4255 m³/h

Heating capacity up to 80 kW

Like FB-A Ultra and in addition

with high-performance fan

with especially quietly running external rotor motor with speed control

possible up to double air capacity

high compression possible

with duct connection frame

FB-A Ultra plus

Construction size 800

Type 834-6-D

Kind of operation*

Air capacity m³/h 4255

Voltage V, 50 Hz 400

Rotational speed min-1 890 / 640 U/min

Motor performance kW 0,31 / 0,20

Power input A 0,72 / 0,41

Heat exchanger 3 reihig

Heating capacity kW 37,9

Sound level in 3 m 68 / 59 dB(A)

Weight 68 kg

Diameter 1290 mm

Height 408 mm

Powerful, quietly running radial fan

FB-A Ultra plus

Page 5: WOLF FB-A Ceiling Mounted Ventilation Units: Comfort Temperature

5 FB-A de luxe

FB-A de luxein wide variety

Especially quiet Blow-out possible laterally and below Suction possible above, above or below

intermediate ceiling, laterally and below Air guiding lamellae individually

adjustable Connection heating medium above Alternatively 2- or 3-row heat exchanger

(CuAl) Control system WOLF-tronic or staged by

transformer Delivery completely wired Recirculating, mixed and outside air

operation

Air capacity up to 3990 m³/h

Heating capacity up to 67,9 kW

Removalbe air guiding lamellae frame

Ceiling Air Heater FB-A de luxe, Variant V, for pure Recirculating Air Operation

Ceiling Air Heater FB-A de luxe, Variant H - for recirculating, mixed and outside air operation

Whisper-quiet and variableFB-A de luxe has been approved on the market for many years.

The advance to comparable units is based on the extremely quiet operation and the particular reliability.

FB-A de luxe is available in variants for horizontal and den vertical blow-out.

Especially quietly running fans provide a super-silent operation.

Ceiling Air Units FB-A de luxe

Construction size 600 700 800

Type 623 633 621 631 626 636 723 733 721 731 726 736 823 833 821 831 826 836

Betriebsart*

Air capacity m³/h 1950 1930 1950 1930 1400 1350 2940 2900 2940 2900 2180 2120 3990 3665 3990 3665 2810 2620

Voltage V, 50 Hz 230 400 400 230 400 400 230 400 400

Rotational speed U/min 1240 1320 / 1000 910 / 720 1300 1330 / 1020 890 / 700 890 890 / 680 670 / 500

Motor performance kW 0,22 0,11 / 0,08 0,05 / 0,033 0,45 0,29 / 0,21 0,11 / 0,07 0,45 0,35 / 0,25 0,16 / 0,095

Power input A 1,0 0,20 / 0,12 0,13 / 0,07 1,90 0,50 / 0,32 0,28 / 0,15 2,10 0,80 / 0,46 0,38 / 0,09

Heat exchanger 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows 2 rows 3 rows

Heating capacity kW 3,9 - 27,0 4,8 - 35,9 3,9 - 27,0 4,8 - 35,9 3,0 - 23,0 4,0 - 30,9 5,8 - 38,8 7,2 - 51,7 5,8 - 38,8 7,2 - 51,7 4,7 - 33,2 6,4 - 38,3 8,4 - 52,7 9,6 - 67,3 8,4 - 52,7 9,6 - 67,3 6,3 - 49,3 8,7 - 62,3

Sound level in 3 m 56 dB(A) 48dB(A) 61 dB(A) 54 dB(A) 60 dB(A) 53 dB(A)

Weight Variant H 23 kg 25 kg 23 kg 25 kg 23 kg 25 kg 35 kg 37,5 kg 35 kg 37,5 kg 35 kg 37,5 kg 42 kg 45 kg 42 kg 45 kg 42 kg 45 kg

Weight Variant V 27,5 kg 29,5 kg 27,5 kg 29,5 kg 27,5 kg 29,5 kg 41,5 kg 44 kg 41,5 kg 44 kg 41,5 kg 44 kg 50 kg 53 kg 50 kg 53 kg 50 kg 53 kg

Length by width 600 x 568 mm 750 x 718 mm 850 x 810 mm

Height Variant H1 254 mm 260 mm 266 mm

Height Variant H2 267 mm 273 mm 279 mm

Height Variant V 378 mm 378 mm 378 mm

Quietly running axial fan

Page 6: WOLF FB-A Ceiling Mounted Ventilation Units: Comfort Temperature

6

Air Guidance Ceiling Air UnitsCeiling air unit FB-A UltraPure recirculating air operationSuction laterally, blow-out laterally

FB-A

Ult

ra

Ceiling air unit FB-A UltraRecirculating, mixed and outside airSuction above, above intermediate ceiling, Blow-out laterally

Ceiling air unit FB-A Ultra plusRecirculating, mixed and outside airSuction above, by air duct in the intermediate ceiling, Blow-out laterally U

ltra

plu

s

Ceiling air heater FB-A de luxe H 2Pure recirculating air operationSuction below Blow-out laterally

FB-A

de

luxe

Ceiling air heater FB-A de luxe H1Pure recirculating air operationSuction above Blow-out laterally

Ceiling air heater FB-A de luxe VPure recirculating air operationSuction laterallyBlow-out below

Ceiling air heater FB-A de luxe H1Recirculating, mixed and outside airSuction above, above intermediate ceiling, Blow-out laterally

Air Guidance Ceiling Air Units by Suction Duct

Ceiling air unit with recirculating air Air suction by suction grid in intermedi-ate ceilingAir suction by recirculating air suction grid, suitable for grid ceilings 625 x 625.

All

FB-A

uni

ts w

ith

suct

ion

abov

e

Ceiling air unit with mixed air attachment partsOutside air suction through the wallThe recirculating air outside air amount is adjusted by the mixed air part. Outside air suction horizontally through the outside wall. Recirculating air suction by recirculating air suction grid.

Ceiling air unit with mixed air attachment partsOutside air suction through the roofThe recirculating air outside air amount is adjusted by the mixed air part. Outside air suction vertically through the roof. Recirculating air suction by adjustable recircu-lating air suction grid.

Recirculating, Mixed, Outside Air Operation

Out versatile product range - tailor-made for your requirements.

In recirculating air operation, the air is sucked out of the room to be heated and blown back into the same room after being heated.

This procedure causes lowest operating costs.

In mixed air operation, fresh air (fresh air amount variably adjustable) is sucked toge-ther with room air.

This procedure reduces heating costs, using partially already heated air out of the hea-ted room, and on the other hand provides the necessary fresh air.

In outside air operation, the air is sucked directly from outside for heating or cooling.

In suitable circumstances, this procedure guarantees clean and unspoilt air.

Possible Applications FB-A

Page 7: WOLF FB-A Ceiling Mounted Ventilation Units: Comfort Temperature

7

Everything under control

In the far background, coordinated technology takes care of perfectly keeping the selected temperature.

Up to 50 ceiling air units can be connected to one switching device, providing quickly optimally distributed warmth or comfortable coolness.

You don‘t see it, yet feel it …

Maximal Comfort: WOLFtronic

D

Three-phase motor400V

2 stages

Alternating-current motor 230 V

1 stage

Repair switch

2 stages automatic system 2 stages

2 stages StandardIndustry

Wet room

= Number of cores of connection pipe

Day / night-time reduction

Day / night-time reduction 2 stages

Servomotor OPEN / CLOSE

Button OPEN / CLOSE Electronic regulatorPosition indicator

0-100 %

Anti-frost thermostat Servomotor continuous

3 stages 5 stages 5 stages

Mot

ors

Swit

chin

g de

vice

sRo

om T

herm

osta

ts

Page 8: WOLF FB-A Ceiling Mounted Ventilation Units: Comfort Temperature

Printed in Germany

8M12

ND

0 v2

WOLF Anlagen-Technik GmbH & Co. KGGeschäftsbereich Heizung - Lüftung - KlimatechnikMünchener Str. 5485290 Geisenfeld, GERMANYTelefon +49 (0) 8452 99-0Telefax +49 (0) 8452 99-250E-Mail info @ wolf-geisenfeld.de Internet www.wolf-geisenfeld.de

GB

WOLF Anlagen-Technik GmbH & Co. KGDivision Heating - Ventilation - Air-conditioning Münchener Str. 5485290 Geisenfeld, GERMANYTelephone +49 (0) 8452 99-0Telefax +49 (0) 8452 99-250E-Mail info @ wolf-geisenfeld.de Internet www.wolf-geisenfeld.de

Mod

ifica

tions

in d

esig

n an

d fu

nctio

n re

serv

ed.