woertz flat cable installation system woertz flat cable installation system

17
WOERTZ Flat Cable Installation System

Upload: phillip-bizzle

Post on 30-Mar-2015

252 views

Category:

Documents


10 download

TRANSCRIPT

Page 1: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

WOERTZ

Flat Cable

Installation System

WOERTZ

Flat Cable

Installation System

Page 2: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Concept Idea

• Continuity in distribution

• Flexibility in installation

• Fast mounting

• Re-usable

installation

L1L2L3NPE

Ouput Output Input Output Output Output

• Mounting failure reduction

• Pre-wiring possibility

• Less cable, lower fire load

• Cost and time saving

Page 3: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

+ + =

Flat Cable Concept

Terminal, Box, Contact, Cable

Page 4: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

• Pointed screw technology• Accurate contact by percing through

the insulation without cutting cupper thread

• Reliability maximum• According international standard IEC

and European ( EN60998-1 and EN60998-2)Woertz Range and experience:

• From 1,5mm2 to 16mm2 connection capability

• More than 30 year experience

Contact

Patented Technology and Product

Page 5: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

• Flat Cable• Flexible Cupper thread• Double insulation• PVC, Halogenfree,...• According international standard

IEC• Direction code

Woertz Offer:• 1,5, 2,5, 10 and 16mm2• More than 30 year experience

Cable

Page 6: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

=

Box and Terminal

• Powering through round cable

• Output by using :

- Screw terminals

- Spring terminals

- Plug

• According IEC / EN Standard

• Mounting code

• IP 20 for Building application

• IP 65 for Industrial application

Page 7: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Installation process

Connecting box on cable:

• Place connecting box

• Insert base plate

• Turn pointed screws

Can be made in advance:

• Input & Output using round cable fitted into terminal or plug depending of box version

Page 8: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

ecobus power5 x 10 mm2

ecobus combi5 x 2,5 mm2 + 2 x 1,5 mm2

ecobus power5 x 2,5 mm2

ecobus data2 x 1,5 mm2

ecofil i7 x 2,5 mm2

ecofil i5 x 16 mm2

BUILDINGI N D U S T R Y &

IP65

Overview

Page 9: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Ecobus Power

Page 10: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Ecobus Combi

Page 11: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Ecobus Data

Page 12: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Ecofil i

Page 13: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Range of application

• Office building• Hospital• Recreational facilities• Hotels• temporary installation• Fair stand installation• Industrial structure• Warehouse• Airport• Parking• Tunnel• Shipyard

Page 14: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Setup Place

• Under-window ducts• Hollow ceiling• Floor ducts• Double floors• Frames• Duct system• Cavities, shafts • Trunkways

Page 15: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Cost - Benefit ratio

ConventionalInstallation

Flat Cableinstallation

20%

80%

37%

38%

0%

20%

40%

60%

80%

100%

Material cost Installation cost

Advantages

Page 16: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Flat Cables Approval• Ecobus Power 5x2,5 (ref 49845) VDE Reg-Nr 7596, Lloyds Reg-01-20038

• Ecobus Power 5x2,5 (ref 49846) VDE Reg-Nr 7597, Lloyds Reg-01-20038

• Ecobus Power 5x10 (ref 49884) VDE Reg-Nr 9475

• Ecobus Power 5x10 (ref 49885) VDE Reg-Nr 9480

• Ecobus Combi (ref 49945) VDE Reg-Nr 9921, Lloyds Reg-01-20038

• Ecobus Combi (ref 40946) VDE Reg-Nr 6548, Lloyds Reg-01-20038

• Ecobus Data (ref 49947) VDE Reg-Nr 6598, Lloyds Reg-01-20038

• Ecobus Data (ref 49948) VDE Reg-Nr 7010, Lloyds Reg-01-20038

• Ecofi i 7x2,5 (ref 49600) VDE Reg-Nr 7654

• Ecofil i 7x2,5 (ref 49601) VDE Reg-Nr 7652

• Ecofil i 5x16 (ref 49605) VDE Reg-Nr 9475

• Ecofil i 5x16 (ref 49606) VDE Reg-Nr 9480, Lloyds Reg-01-20038

Page 17: WOERTZ Flat Cable Installation System WOERTZ Flat Cable Installation System

Connection Boxes Approval• Ecobus Power 5x2,5 CE, SEV, VDE, NF, DNV, ÖVE, KEMA, ASTA, NEMKO, DEMKO, SEMKO, FIMKO, Lloyds register

• Ecobus power 5x10CE, DNV, VDE, SEV, NEMKO, OVE, DEMKO, SEMKO, FIMKO, KEMA, ASTA

• Ecobus CombiCE, SEV, DNV, ÖVE, KEMA, ASTA, NEMKO, DEMKO, SEMKO, FIMKO, Lloyds register

• Ecofi i 7x2,5 CE, VDE

• Ecofil i 5x16 CE, VDE, Lloyds register