Concept Idea
• Continuity in distribution
• Flexibility in installation
• Fast mounting
• Re-usable
installation
L1L2L3NPE
Ouput Output Input Output Output Output
• Mounting failure reduction
• Pre-wiring possibility
• Less cable, lower fire load
• Cost and time saving
+ + =
Flat Cable Concept
Terminal, Box, Contact, Cable
• Pointed screw technology• Accurate contact by percing through
the insulation without cutting cupper thread
• Reliability maximum• According international standard IEC
and European ( EN60998-1 and EN60998-2)Woertz Range and experience:
• From 1,5mm2 to 16mm2 connection capability
• More than 30 year experience
Contact
Patented Technology and Product
• Flat Cable• Flexible Cupper thread• Double insulation• PVC, Halogenfree,...• According international standard
IEC• Direction code
Woertz Offer:• 1,5, 2,5, 10 and 16mm2• More than 30 year experience
Cable
=
Box and Terminal
• Powering through round cable
• Output by using :
- Screw terminals
- Spring terminals
- Plug
• According IEC / EN Standard
• Mounting code
• IP 20 for Building application
• IP 65 for Industrial application
Installation process
Connecting box on cable:
• Place connecting box
• Insert base plate
• Turn pointed screws
Can be made in advance:
• Input & Output using round cable fitted into terminal or plug depending of box version
ecobus power5 x 10 mm2
ecobus combi5 x 2,5 mm2 + 2 x 1,5 mm2
ecobus power5 x 2,5 mm2
ecobus data2 x 1,5 mm2
ecofil i7 x 2,5 mm2
ecofil i5 x 16 mm2
BUILDINGI N D U S T R Y &
IP65
Overview
Ecobus Power
Ecobus Combi
Ecobus Data
Ecofil i
Range of application
• Office building• Hospital• Recreational facilities• Hotels• temporary installation• Fair stand installation• Industrial structure• Warehouse• Airport• Parking• Tunnel• Shipyard
Setup Place
• Under-window ducts• Hollow ceiling• Floor ducts• Double floors• Frames• Duct system• Cavities, shafts • Trunkways
Cost - Benefit ratio
ConventionalInstallation
Flat Cableinstallation
20%
80%
37%
38%
0%
20%
40%
60%
80%
100%
Material cost Installation cost
Advantages
Flat Cables Approval• Ecobus Power 5x2,5 (ref 49845) VDE Reg-Nr 7596, Lloyds Reg-01-20038
• Ecobus Power 5x2,5 (ref 49846) VDE Reg-Nr 7597, Lloyds Reg-01-20038
• Ecobus Power 5x10 (ref 49884) VDE Reg-Nr 9475
• Ecobus Power 5x10 (ref 49885) VDE Reg-Nr 9480
• Ecobus Combi (ref 49945) VDE Reg-Nr 9921, Lloyds Reg-01-20038
• Ecobus Combi (ref 40946) VDE Reg-Nr 6548, Lloyds Reg-01-20038
• Ecobus Data (ref 49947) VDE Reg-Nr 6598, Lloyds Reg-01-20038
• Ecobus Data (ref 49948) VDE Reg-Nr 7010, Lloyds Reg-01-20038
• Ecofi i 7x2,5 (ref 49600) VDE Reg-Nr 7654
• Ecofil i 7x2,5 (ref 49601) VDE Reg-Nr 7652
• Ecofil i 5x16 (ref 49605) VDE Reg-Nr 9475
• Ecofil i 5x16 (ref 49606) VDE Reg-Nr 9480, Lloyds Reg-01-20038
Connection Boxes Approval• Ecobus Power 5x2,5 CE, SEV, VDE, NF, DNV, ÖVE, KEMA, ASTA, NEMKO, DEMKO, SEMKO, FIMKO, Lloyds register
• Ecobus power 5x10CE, DNV, VDE, SEV, NEMKO, OVE, DEMKO, SEMKO, FIMKO, KEMA, ASTA
• Ecobus CombiCE, SEV, DNV, ÖVE, KEMA, ASTA, NEMKO, DEMKO, SEMKO, FIMKO, Lloyds register
• Ecofi i 7x2,5 CE, VDE