with interchangeable screw placement techniques, you...
TRANSCRIPT
K-WIRELESS DILATOR TECHNIQUE- A trio of dilators directly paves your way
from pedicle awl to screw placement- A smooth and intuitive screw
placement procedure- Radiolucent dilator. Better visualization- "Soft tissue-less" field of work- No need for a k-wire
- Preload your screwdriver with a pedicle screw, tower, and k-wire
- One instrument takes you from skin incision to final screw placement
- Less time. Less x-ray exposure
ProMIS™ - YOUR CHOICE FOR SCREW PLACEMENTWith interchangeable screw placement techniques, you can switch intraoperatively based on your assessment of the situation
- The most state-of-the-art screw placement technique with least steps and fewest instruments - An advanced patented screw driver with an integrated k-wire and tower for direct screw placement- The sharp k-wire tip anchors your entry point while you determine desired trajectory; then open the cortical
bone for initial screw fixation- Back out the sharp tip at any point during the screw advancement, leaving a blunt-tip pedicle screw which
is accurately guided by the native pedicle to its final positioning- Screw is in final position with no exchange of instruments- Less x-ray exposure- Safe k-wire and k-wireless management with full control over tip and screw advancement
DIRECT SKIN-TO-SCREW
DIRECT SKIN-TO-SCREW TECHNIQUE
ROD PLACEMENT
- Place the rods, reduce, and close - You're out of the operating room- Robust towers that detach and
re-attach easily- In-tower single step reduction- Better leverage and power during
compression/distraction
ANCHOR GUIDANCE
PREPARE ENTRY POINT
ESTABLISH TRAJECTORY
INSERT SCREW
JAMSHIDI TECHNIQUE- Utilize a robust, reusable Jamshidi
with an integrated k-wire- Fewer disposable instruments
TAP-SHIDI TECHNIQUE- Work with a Tap and an integrated
k-wire as you would use a Jamshidi- In the time you place a Jamshidi, you
already complete the tapping- Insert the pedicle screw over a k-wire - Fewer steps. Fewer instruments
- Fewer steps. Faster procedure- Less radiation exposure for operating room staff and patients- Small uniform skin incisions with least muscle trauma- Sterile implants- More economical reprocessing
ProMIS™ Fixation SystemDELIVERS VALUE TO PATIENTS AND HOSPITALS
PATENTED SCREW SURFACEWith documented improvement in screw-bone integration*
INDIVIDUALLY PACKEDSTERILE IMPLANTS
ProMIS™ Fixation System
Competition Premia Spine
Advanced MIS screw placement
* Effect of Micrometer-Scale Roughness of the Surface of Ti6Al4V Pedicle Screw in Vitro and Vivo. Schwartz, Boyan et. al. The Journal of Bone and Joint Surgery. 2OO8. p. 2485-2498
FEWER INSTRUMENTS. MORE ECONOMICAL REPROCESSING
Screw placement tools Reduction tools Rod insertion & fixation tools
Special thanks to Dr. Bernd Illerhaus
CONTACT US
Premia Spine Inc.15OO Market Street, 12th floor East Tower, Philadelphia PA [email protected] | TEL: (215) 2O7-O137