wireless intuitive probe system
TRANSCRIPT
![Page 1: Wireless Intuitive Probe System](https://reader035.vdocuments.mx/reader035/viewer/2022071602/613d77a6736caf36b75dacd1/html5/thumbnails/1.jpg)
Wireless Intuitive Probe System
This document assumes that:both the OMP40-2 work probe and the OTS tool probe are correctly installed and operational•the user is familiar with the safe operation of Haas machine tools and the functionality of the control•
This document is designed to supplement the information provided by the WIPS software screens: it is not intended to provide stand alone instruction.
Set-up keypad
Auger, coolant and jogging
keypad
Cursor keypad
Override keypad
Display keypad
Alphabetic keypad
Mode keypad
Numeric keypad
Control overview
Enter the Intuitive Programming System (IPS)
MANUAL SETUP FACE DRILL POCKET MILLING ENGRAVING VQC
MANUAL MODE
=
= SETUP =
MANUAL SETUP FACE DRILL POCKET MILLING ENGRAVING VQC
WORK TOOL TOOL PROBE CALIBRATION WORK PROBE CALIBRATION
WORK SETUP
Both the work probe and the tool probe must be calibrated before WIPS probing during manufacture.
Starting position=
1
Note: Red font indicates currently active menu option
![Page 2: Wireless Intuitive Probe System](https://reader035.vdocuments.mx/reader035/viewer/2022071602/613d77a6736caf36b75dacd1/html5/thumbnails/2.jpg)
Work probe calibration
x 3 = WORK PROBE CALIBRATION
Work probe calibration requires the use of an inner diameter calibration ring, ring gauge or bored hole of known diameter. Securely fix the calibration artefact being used to the machine table.
Load a calibration bar to the machine spindle.
Place a shim of known thickness on the top surface of the calibration artefact.
L
MANUAL SETUP FACE DRILL POCKET MILLING ENGRAVING VQC
WORK TOOL TOOL PROBE CALIBRATION WORK PROBE CALIBRATION
TOOL LENGTH0. 000 mm
Z POSITION0. 000 mm
BALL DIAMETER0. 000 mm
SHIM0. 000 mm
CAL MASTER DIA0. 000 mm
INCOMPLETECALIBRATION
0. 000 mmPROBE LENGTH
T
A
B
C
D
E
F
GL1
Ø
Ø1
ii iii
Step 8
≈5 - 10 mm
i
& -Z
Step 1
L(calibration bar length)
T(shim thickness)
Step 2 Step 3
Remove shim Load work probe
~ L1(approx. length of work probe)
Step 4
Ø(probe ball diameter)
Ø1(diameter of
calibration artefact)
Step 5 Step 6
To run calibration cycle
Step 7
INCOMPLETECALIBRATION
COMPLETEDCALIBRATION
INCOMPLETECALIBRATION
COMPLETEDCALIBRATION
Step 9
A
B C
D
E F
G
ii
iii
i i& &
&
ii& ii&
From starting position
2
To position probe
![Page 3: Wireless Intuitive Probe System](https://reader035.vdocuments.mx/reader035/viewer/2022071602/613d77a6736caf36b75dacd1/html5/thumbnails/3.jpg)
MANUAL SETUP FACE DRILL POCKET MILLING ENGRAVING VQC
WORK TOOL TOOL PROBE CALIBRATION WORK PROBE CALIBRATION
Wrk Zero Ofst
54Y O�set
-359. 297
Z O�set-463. 519
0.A O�set
-288. 736X O�set
0.B O�set
Work MaterialLOW CARBON UNALLYOED STEEL
4Corner
0. 000 mmIncremental Z
0. 000 mmIncremental X
Position probe near the approx. corner and justabove the Z axis surface.Press CYCLE START.
OUTSIDE CORNER FINDING < or > to change
Press F2 toset o�setsusing probe.
0. 000 mmIncremental Y
1 2
34
Updating work offsets
Note: Only OUTSIDE CORNER FINDING and INSIDE CORNER FINDING will update offsets in X, Y and Z. All other feature types will require at least one additional cycle to update all offsets.
AB
C1
2
3
4
Example: Outside corner finding
1 2
34
Position probe tip ≈10 mm above selected corner
Select offsets to update
Step 1
x 2 Work MaterialLOW CARBON UNALLOYED STEEL
Step 2 (optional)
Select work
material
1 2
34
1 2
34
Step 4
4Corner
0. 000 mmIncremental Z
0. 000 mmIncremental X
Position probe near the approx. corner and justabove the Z axis surface.Press CYCLE START.
OUTSIDE CORNER FINDING < or > to change
0. 000 mmIncremental Y
1 2
34
&Corner number
Step 4
-Z move to surface
Step 5
& Move before contact on side faces
Step 6
ii
i
A B
C i
C1 ii
C2 C3 C4
&
From starting position
3
4Approx. Dia.
0. 000 mmX Adjust
0. 000 mmY Adjust
Position probe near the approx. centre and just below the Z axis surface.Press CYCLE START.
BORE < or > to change
=
Step 3
C i
Step 7
To run calibration cycle
![Page 4: Wireless Intuitive Probe System](https://reader035.vdocuments.mx/reader035/viewer/2022071602/613d77a6736caf36b75dacd1/html5/thumbnails/4.jpg)
MANUAL SETUP FACE DRILL POCKET MILLING ENGRAVING VQC
WORK TOOL TOOL PROBE CALIBRATION WORK PROBE CALIBRATION
X POSITION0. 000 mm
Z POSITION0. 000 mm
LENGTH0. 000 mm
DIAMETER0. 000 mm
INCOMPLETECALIBRATION
2TOOL OFFSET
Y POSITION0. 000 mm
Tool probe calibration
x 2 = TOOL PROBE CALIBRATION
A
B
C
D
F
E
Ensure the machine spindle contains a calibration bar.
≈5 mm
L
Ø
&
Step 1
Tool offset number/tool number
Step 3
L(length of calibration bar)
Step 4
Ø(diameter of calibration bar)
Step 5
INCOMPLETECALIBRATION
COMPLETEDCALIBRATION
INCOMPLETECALIBRATION
COMPLETEDCALIBRATION
Step 7
&
Step 2 iii
C
D
F
E
A
B ii
i&
&
i&
i&
From starting position
4
Step 6
To run calibration cycle
![Page 5: Wireless Intuitive Probe System](https://reader035.vdocuments.mx/reader035/viewer/2022071602/613d77a6736caf36b75dacd1/html5/thumbnails/5.jpg)
For installation and maintenance information on the OMP40-2 work probe see OMP40-2 optical machine probe Installation guide (Renishaw part no. H-4071-8504) or OMP40-2 Quick-start guide (Renishaw part no. A-4071-8500).
For installation and maintenance information on the OTS tool probe see OTS optical tool setter Installation guide (Renishaw part no. H-5514-8504) or OTS optical tool setter Quick-start guide (Renishaw part no. A-5514-8500).
These documents are available to download from www.renishaw.com/mtp
MANUAL SETUP FACE DRILL POCKET MILLING ENGRAVING VQC
WORK TOOL TOOL PROBE CALIBRATION WORK PROBE CALIBRATION
N/A
2
0
0. 000 mm
Calculated
2Tool Displayed
User
0. 000 mm
0. 000 mm
N/A
0
Spindle RPM
Feedrate
Flutes
Point
Tool Diameter Pitch
Z Wear
Tool Wear
Coolant PosTool Material
Z LengthTool Type
0. 000 mm
DRILL
WRITETOSET
Press ATC FWDor ATC REV tochange the tooldisplayed.
Press NEXT TOOLto change thetool in spindle.
Press F2 to settool dimensionsusing probe.
Tool set-up
x 1 = TOOLA
Step 1
Note: If no value is entered in the Z distance field (-Z distance from the tool tip), tool diameter will not be measured and the cycle will record tool length only.
Step 2
Step 3
Tool dimensions
A
1
0. 000 mm
0. 000 mm
PROBE - TOOL DIMENSIONS
0. 000 mm
Press CYCLE STARTto automaticallyset tool lengthand diameter.
Tool O�set #
Approx Length
Approx Dia
Z distance
=
From starting position
5
Step 4
To run calibration cycle
![Page 6: Wireless Intuitive Probe System](https://reader035.vdocuments.mx/reader035/viewer/2022071602/613d77a6736caf36b75dacd1/html5/thumbnails/6.jpg)
Renishaw plc
New Mills, Wotton-under-Edge, Gloucestershire GL12 8JR United Kingdom
T +44 (0) 1453 524524 F +44 (0) 1453 524901 E [email protected]
www.renishaw.com
Australia
T +61 3 9521 0922 E [email protected]
Austria
T +43 2236 379790 E [email protected]
Brazil
T +55 11 4195 2866 E [email protected]
Canada
T +1 905 828 0104 E [email protected]
The People’s Republic of China
T +86 21 6180 6416 E [email protected]
Czech Republic
T +420 548 216 553 E [email protected]
France
T +33 1 64 61 84 84 E [email protected]
Germany
T +49 7127 9810 E [email protected]
Hong Kong
T +852 2753 0638 E [email protected]
Hungary
T +36 23 502 183 E [email protected]
India T +91 80 6623 6000 E [email protected]
Israel
T +972 4 953 6595 E [email protected]
Italy
T +39 011 966 10 52 E [email protected]
Japan
T +81 3 5366 5316 E [email protected]
Malaysia
T +60 3 5361 4420 E [email protected]
The Netherlands
T +31 76 543 11 00 E [email protected]
Poland
T +48 22 577 11 80 E [email protected]
Russia
T +7 495 231 16 77 E [email protected]
Singapore
T +65 6897 5466 E [email protected]
Slovenia
T +386 1 527 2100 E [email protected]
South Korea
T +82 2 2108 2830 E [email protected]
Spain
T +34 93 663 34 20 E [email protected]
Sweden
T +46 8 584 90 880 E [email protected]
Switzerland
T +41 55 415 50 60 E [email protected]
Taiwan
T +886 4 2473 3177 E [email protected]
Thailand
T +66 2 746 9811 E [email protected]
Turkey
T +90 216 380 92 40 E [email protected]
UK (Head Office)
T +44 1453 524524 E [email protected]
USA
T +1 847 286 9953 E [email protected]
For all other countries
T +44 1453 524524 E [email protected]
Renishaw worldwideRenishaw applies innovation to provide solutions to your problemsRenishaw is an established world leader in metrology, providing high performance, cost-effective solutions for measurement and increased productivity. A worldwide network of subsidiary companies and distributors provides exceptional service and support for its customers.
Renishaw designs, develops and manufactures products which conform to ISO 9001 standards.
Renishaw provides innovative solutions using the following products:
• Probe systems for inspection on CMMs (co-ordinate measuring machines).
• Systems for job set-up, tool setting and inspection on machine tools.
• Scanning, digitising and dental systems.
• Laser and automated ballbar systems for performance measurement and calibration of machines.
• Encoder systems for high accuracy position feedback.
• Spectroscopy systems for non-destructive material analysis in laboratory and process environments.
• Styli for inspection and tool setting probes.
• Customised solutions for your applications.
Issued February 2009 Part no. H-2000-6596-01
© 2009 Renishaw plc. All rights reserved. Renishaw reserves the right to change specifications without noticeRENISHAW® and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries. apply innovation is a trademark of Renishaw plc.
RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT. *H-2000-6596-01*