 Evo Design s.r.l. xxxx TOWER  DESIGN REVIEW REPORT Location xxx WIND LOADS CALCULATION PER BS 6399-2 FOR A BASIC WIND SPEED OF 25 m/s V b  25  m m m m s s basic wind speed  K b  1 building type factor in accordance with BS 6399-2 Table 1. for ramed building with structural walls arround lifts and stairs only (e.g. office buildings of open plan or without partitions)  H r  30  m m m m Reference height  H e  H r Effective height to be considered in the calculations Basic wind speed calculation in accordance with BS 6399-2 Section 2.2.1 S  100 site altitude above sea level in meters - Section 2.2.2.2 S a  + 1 0.001  S altitude factor = S a  1.1 S d  1 direction fac tor - Section 2.2. 2.3 for unknow n wind direction S s  1 seasonal factor - Section 2.2.2.4 S  p  1 probability factor - Section 2.2.2.5 V s  V b  S a  S d  S s  S  p  = V s  27.5  m m m m s s Effective wind speed calculation in accordance with BS 6399-2 Section 2.2.3 S b  1.96 terrain and building factor - Section 2.2.3.3 - Table 4 V e  V s  S b  = V e  53.9  m m m m s s effective wind speed for building heights larger that the width some reduction in wind loads may be obtained by dividing the building into a number of parts - in our case the reduction is neglijable. L  51  m m m m building length W  25 building width

Upload: amro-ahmad-ali

Post on 05-Oct-2015

84 views

Category:

Documents


4 download

DESCRIPTION

jo

TRANSCRIPT

  • Evo Design s.r.l. xxxx TOWER

    DESIGN REVIEW REPORT Location xxx

    WIND LOADS CALCULATION PER BS 6399-2

    FOR A BASIC WIND SPEED OF 25 m/s

    Vb 25 mmmm

    ssssbasic wind speed

    Kb 1 building type factor in accordance with BS 6399-2 Table 1.for ramed building with structural walls arround lifts and stairs only (e.g. office buildings of open plan or without partitions)

    Hr 30 mmmm Reference height

    He Hr Effective height to be considered in the calculations

    Basic wind speed calculation in accordance with BS 6399-2 Section 2.2.1

    S 100 site altitude above sea level in meters - Section 2.2.2.2

    Sa +1 0.001 S altitude factor

    =Sa 1.1

    Sd 1 direction factor - Section 2.2.2.3 for unknown wind direction

    Ss 1 seasonal factor - Section 2.2.2.4

    Sp 1 probability factor - Section 2.2.2.5

    Vs Vb Sa Sd Ss Sp =Vs 27.5 mmmm

    ssss

    Effective wind speed calculation in accordance with BS 6399-2 Section 2.2.3

    Sb 1.96 terrain and building factor - Section 2.2.3.3 - Table 4

    Ve Vs Sb =Ve 53.9 mmmm

    sssseffective wind speed

    for building heights larger that the width some reduction in wind loads may be obtained by dividing the building into a number of parts - in our case the reduction is neglijable.

    L 51 mmmm building length

    W 25 building width

  • Evo Design s.r.l. xxxx TOWER

    DESIGN REVIEW REPORT Location xxx

    =L

    He1.7 external pressure coeff. - longitudinal per BS 6399-2 -

    Table 5

    Longitudinal coefficients

    Cpe.winward.L 0.749 interpolation - values in Table 5

    Cpe.leeward.L 0.249

    =W

    He0.833

    1

    mmmmexternal pressure coeff. - transversal per BS 6399-2 -Table 5

    Transversal coefficients

    Cpe.winward.T 0.800 values in Table 5

    Cpe.leeward.T 0.300

    Ca.L 0.848 in accordance with BS 6399-2 Figure 4

    Ca.T 0.816

    Dynamic pressure per BS 6399-2 Section 2.1.2

    qs 0.613

    Ve

    mmmm

    ssss

    2

    PaPaPaPa in accordance with BS 6399-2 Formula 1

    =qs 1.781 10

    3 PaPaPaPa

    pe.winward.L qs Cpe.winward.L Ca.L in accordance with BS 6399-2 Formula 2

    =pe.winward.L 1.131 kPakPakPakPa

    pe.leeward.L qs Cpe.leeward.L Ca.L in accordance with BS 6399-2 Formula 2

    =pe.leeward.L 0.376 kPakPakPakPa

  • Evo Design s.r.l. xxxx TOWER

    DESIGN REVIEW REPORT Location xxx

    pe.winward.T qs Cpe.winward.T Ca.T in accordance with BS 6399-2 Formula 2

    =pe.winward.T 1.163 kPakPakPakPa

    pe.leeward.T qs Cpe.leeward.T Ca.T in accordance with BS 6399-2 Formula 2

    =pe.leeward.T 0.436 kPakPakPakPa